Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON SCIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Micro-scale fusion in dense relativistic nanowire array plasmas

Nuclear fusion is regularly created in spherical plasma compressions driven by multi-kilojoule pulses from the world’s largest lasers. Here we demonstrate a dense fusion environment created by irradiating arrays of deuterated nanostructures with joule-level pulses from a compact ultrafast laser. The irradiation of ordered deuterated polyethylene nanowires arrays with femtosecond pulses of relativistic intensity creates ultra-high energy density plasmas in which deuterons (D) are accelerated up to MeV energies, efficiently driving D–D fusion reactions and ultrafast neutron bursts. We measure up to 2 × 10 6 fusion neutrons per joule, an increase of about 500 times with respect to flat solid targets, a record yield for joule-level lasers. Moreover, in accordance with simulation predictions, we observe a rapid increase in neutron yield with laser pulse energy. The results will impact nuclear science and high energy density research and can lead to bright ultrafast quasi-monoenergetic neutron point sources for imaging and materials studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast-Neutron Spectrometry Using a 3He Ionization Chamber and Digital Pulse Shape Analysis

Digital pulse shape analysis (dPSA) has been used with a Cuttler-Shalev type 3He proportional counter to measure the fast neutron spectra of bare 252Cf and 241AmBe neutron sources. Measurements have also been made to determine the attenuated fast neutron spectra of 252Cf shielded by several materials including water, graphite, liquid nitrogen, magnesium, and tungsten. Rise-time dPSA has been employed using the common rise-time approach for analyzing n +3He ? 1H + 3H ionization events and a new approach has been developed to improve the fidelity of these measurements. Simulations have been performed for the different experimental arrangements and are compared, demonstrating general agreement between the dPSA processed fast neutron spectra and predictions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effects of low- Z shielding on uranium isotope discrimination using the time-emission profiles of long-lived delayed neutrons

Characteristic radiation signals can often be obscured or distorted by relatively small amounts of shielding, as is the case for highly-enriched uranium (HEU). Methods that can detect and identify special nuclear material (SNM) even in the presence of shielding are therefore of high value in many nuclear security and nonproliferation applications. It has been previously shown that the buildup and decay time profiles of long-lived delayed neutron emission from induced fission are unique and can be used to successfully discriminate between uranium isotopes and infer enrichment without the need for a calibration standard. Because the long-lived delayed neutron precursors exhibit decay times on the order of tens of seconds, their time profiles are not sensitive to the delays associated with scattering or diffusion in shielding materials, which occur on much shorter time scales. The use of capture-based neutron detectors can also mitigate the effects of shielding, because unlike recoil-based detectors, they do not have a low-energy detection threshold, so that neutrons that lose their energy in the shielding are still detectable. In this work, the effects of low-Z shielding on the discrimination of uranium isotopes using delayed neutron time profile measurements are investigated for the first time. Furthermore, the delayed neutron buildup and decay time profiles of polyethylene-shielded HEU and depleted uranium objects are measured using two different capture-gated detector designs. The recorded profiles show good agreement with the shapes predicted from six-group delayed neutron models even with the shielding in place, and the enrichment of the HEU and DU objects was estimated accurately to within 5%. While this method shows potential for discriminating and characterizing extreme cases of enrichment when a moderate amount of shielding is present, simulation results suggest that significant limitations exist for intermediate enrichment levels due to distortions to the delayed neutron time profile caused by neutron reflection in the shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanical Activation and Cation Site Disorder in MgAl 2 O 4

The synthesis and crystallographic site occupancy were investigated for MgAl 2 O 4 with and without mechanical activation of the precursor powders. Heating to 1200 °C or higher resulted in the formation of a single spinel phase regardless of whether the powders were mechanically activated or not. Neutron diffraction analysis was used to determine cation site occupancy and revealed that mechanical activation resulted in a lower degree of cation site inversion compared to the nonactivated materials, which indicated that the powders were closer to thermodynamic equilibrium. This is the first study to characterize the effects of mechanical activation on crystallographic site occupancy in magnesium aluminate spinel using neutron diffraction.

36 MATERIALS SCIENCE↗

A workshop on enhanced national capability for neutron scattering

This two-day workshop will engage the international neutron scattering community to vet and improve the Lujan Center Strategic Plan 2007-2013 (SP07). Sponsored by the LANL SC Program Office and the University of California, the workshop will be hosted by LANSCE Professor Sunny Sinha (UCSD). Endorsement by the Spallation Neutron Source will be requested. The discussion will focus on the role that the Lujan Center will play in the national neutron scattering landscape assuming full utilization of beamlines, a refurbished LANSCE, and a 1.4-MW SNS. Because the Lujan Strategic Plan is intended to set the stage for the Signature Facility era at LANSCE, there will be some discussion of the long-pulse spallation source at Los Alamos. Breakout groups will cover several new instrument concepts, upgrades to present instruments, expanded sample environment capabilities, and a look to the future. The workshop is in keeping with a request by BES to update the Lujan strategic plan in coordination with the SNS and the broader neutron community. Workshop invitees will be drawn from the LANSCE User Group and a broad cross section of the US, European, and Pacific Rim neutron scattering research communities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron and X-Ray Scattering Studies of New Green Cement, and Nanoconfined Water

This is the Final report on DE-FG02-90ER45429 for the time period from September 1, 1990 to May 31, 2017. The Principal Investigator is Sow-Hsin Chen, Department of Nuclear Science and Engineering, Massachusetts Institute of Technology (MIT), Cambridge, MA 02139 (email: sowhsin@mit.edu). The Administrative Point of Contact at MIT is Sarah Svenson, Senior Contract Administrator, Office of Sponsored Programs, Tel: 617-253-2495, ssvenson@mit.edu. The DOE Program is the Office of Basic Energy Sciences (BES); Program manager is Dr. P. Thiyagarajan, Neutron Scattering SC-22.2/, Germantown Bldg., Germantown, MD 20874 . During these 27 years, the scientific activities has had a number developing emphases, as reflected from the change of Project Title in 1990 as “Construction of a Small Angle Neutron Scattering Spectrometer for Investigation of Microemulsions and Micellar Solutions in Bulk, in Porous Materials...” to “Neutron and X-Ray Scattering Studies of New Green Cement, and Nanoconfined Water” in the last renewal period, 2015-2017, with many title changes in between. Progress Report for each sub-project period was reported to DOE with detailed activity and budgetary reports. It is fair to summary that the chief activity has been in the use neutron, x-ray and laser spectroscopy to investigate materials properties of complex fluids and soft condensed matter. It started with conducting neutron and X-ray scattering experiments to study the structure and dynamics of glass-forming liquids in general first, then more specifically in the case of supercooled water in confined geometry, and culminating in the final study of new green cement. Experiments were conducted at various DOE supported national neutron facilities including ORNL, ANL, BNL and Los Alamos, as well as at NIST/NCNR. Whenever possible, experiments were also performed at numerous world-class facilities, such as those at Saclay and the Institut Laue Langevin (ILL) in Grenoble, France, and at National Synchrotron Radiation Research Center (NSRRC) in recent years in Taiwan, etc. Leveraging on the large number of international collaborate activities, a substantial percentage of activities were supported with collaborators’ own funding sources. These have help to carry out DOE’s mission and produce impressive research products far beyond what was possible with only DOE funding supports. The chief product during this period, 1990-2017, includes (1) Three hundred and eight scientific articles published in peer-reviewed and high-impacted scientific journals during 1990-2017, and a dozen monographs including four books for scientists and graduate students, (2) Twenty-four scientific conferences organized and 209 papers presented at many national and international conferences, (3) educate and train 9 post-doctoral fellows and 28 students including 22 Ph.D. students, 3 M.S. students, and 3 in other categories by providing a research experience in neutron and X-Ray scattering techniques, most of them were supported wholly or in part in the scientific topic of this award during the funding period and (4) numerous high-visibility awards and honors. This final report summarizes and details these research activities and products. At the close of this funding period, the fund from DOE has been totally spent.

07 ISOTOPE AND RADIATION SOURCES↗

Using an onion like neutron scattering instrument model to quickly optimize design parameters

When designing a neutron scattering instrument, one of the major challenges is the many parameters, generally interdependent, within the optimization. In this work we describe an approach using McStas 1-3 to quickly get a good overview of how changes in instrument parameters will impact neutron scattering instrument performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Scientific Justification for a U.S. Domestic High-Performance Reactor-Based Research Facility

The Basic Energy Science Advisory Committee (BESAC) was charged with forming a subcommittee to assess the scientific justification for a U.S. domestic high-performance reactor-based research facility in order to continue providing the U.S scientific community with leading neutron capabilities in support of DOE's missions in science, energy, environment, and national security. The assessment included consideration of current international plans and existing domestic facility infrastructure. The subcommittee held a series of meetings from August 19, 2019 to April 24, 2020 that included DOE senior officials, leaders of national and international neutron facilities (SNS, HFIR, NIST, ILL, FRM-II), chairs of the NAS and POPA HEU-LEU committees, and outside experts on important areas of science, technology, and industry where high flux nuclear reactor facilities make important contributions. Also included were tours of neutron facilities (SNS, HFIR, NIST, BR2 reactor, and the planned Jules Horowitz Reactor). This July 2020 (revised 10-28-2020) report describes scientific use cases, brief summaries of existing and planned neutron facilities in the US and Europe, a comprehensive review of HFIR, a comprehensive discussion of the current state of progress on HEU-LEU conversion, user information from NIST and ORNL, and three recommendations to DOE for moving forward.

36 MATERIALS SCIENCE↗

Study of Extracted Beam Characteristics of the Photoneutron Source at the Institute for Nuclear Research of the Russian Academy of Sciences

The characteristics of the extracted beam of thermal neutrons at the IN-LUE photoneutron source are investigated. A collimator with a cross-section diameter of 30 mm, located at an angle of 67° relative to the electron beam direction, was used to extract neutrons from the source. The neutron flux density as a function of the distance from the source center and the distribution of flux density over the distance from the collimator axis (beam profile) are obtained.

43 PARTICLE ACCELERATORS↗

Annual Report FY2013-- A Kinematically Complete, Interdisciplinary, and Co-Institutional Measurement of the 19F(α,n) Cross-section for Nuclear Safeguards Science

The goal of this proposal is to enable neutron detection for precision Non-Destructive Assays (NDAs) of actinide-fluoride samples. Neutrons are continuously generated from a UFx matrix in a container or sample as a result of the interaction of alpha particles from uranium-decay α particles with fluorine nuclei in the matrix. Neutrons from 19F(α,n)22Na were once considered a poorly characterized background for assays of UFx samples via 238U spontaneous fission neutron detection [SMI2010B]. However, the yield of decay-α-driven neutrons is critical for 234,235U LEU and HEU assays, as it can used to determine both the total amount of uranium and the enrichment [BER2010]. This approach can be extremely valuable in a variety of safeguard applications, such as cylinder monitoring in underground uranium storage facilities, nuclear criticality safety studies, nuclear materials accounting, and other nonproliferation applications. The success of neutron-based assays critically depends on an accurate knowledge of the cross section of the (α,n) reaction that generates the neutrons. The 40% uncertainty in the 19F(α,n)22Na cross section currently limits the precision of such assays, and has been identified as a key factor in preventing accurate enrichment determinations [CRO2003]. The need for higher quality cross section data for (α,n) reactions has been a recurring conclusion in reviews of the nuclear data needs to support safeguards. The overarching goal of this project is to enable neutron detection to be used for precision Non- Destructive Assays (NDAs) of actinide-fluoride samples. This will significantly advance safeguards verification at existing declared facilities, nuclear materials accounting, process control, nuclear criticality safety monitoring, and a variety of other nonproliferation applications. To reach this goal, Idaho National Laboratory (INL), in partnership with Oak Ridge National Laboratory (ORNL), Rutgers University (RU), and the University of Notre Dame (UND), will focus on three specific items: (1) making a precision (better than 10 %) determination of the absolute cross section of the 19F(α,n)22Na reaction as a function of energy; (2) determining the spectrum of neutrons and γ-rays emitted from 19F(α,n)22Na over an energy range pertinent to NDA; and (3) performing simulations with this new cross section to extract the neutron yield (neutrons/gram/second) and resulting neutron- and gamma ray-spectra when α particles interact with fluorine nuclei in actinide samples, to aid in the design and reduce uncertainty of future NDA measurements and simulations.

VANDLE, HPGe gamma-ray detector, liquid neutron de↗

Characterization of shielding materials used in neutron scattering instrumentation

The nuclear cross-sections of certain isotopes make some materials excellent candidates for neutron shielding. We have performed a series of measurements examining the transmission, reflection, and nuclear Bragg scattering of a series of common materials used for neutron shielding. Here, we concentrate on characterizing the materials most likely to be used in neutron scattering instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrawide bandgap semiconductor h-BN for direct detection of fast neutrons

III-nitride wide bandgap semiconductors have contributed on the grandest scale to many technological advances in lighting, displays, and power electronics. Among III-nitrides, BN has another unique application as a solid-state neutron detector material because the isotope B-10 is among a few elements that have an unusually large interaction cross section with thermal neutrons. A record high thermal neutron detection efficiency of 60% has been achieved by B-10 enriched h-BN detectors of 100 μm in thickness in our group. However, direct detection of fast neutrons with energies above 1 MeV is highly challenging due to the extremely low interaction cross section of fast neutrons with matter. We report the successful attainment of 0.4 mm thick freestanding h-BN 4"-diameter wafers, which enabled the demonstration of h-BN fast neutron detectors capable of delivering a detection efficiency of 2.2% in response to a bare AmBe neutron source. Furthermore, it was shown that the energy information of incoming fast neutrons is retained in the neutron pulse-height spectra. A comparison of characteristics between h-BN fast and thermal neutron detectors is summarized. Neutron detectors are vital diagnostic instruments for nuclear and fusion reactor power and safety monitoring, oil field exploration, neutron imaging and therapy, as well as for plasma and material science research. With the outstanding attributes resulting from its ultrawide bandgap (UWBG), including the ability to operate at extreme conditions of high power, voltage, and temperature, the availability of h-BN UWBG semiconductor detectors with the capability of simultaneously detecting thermal and fast neutrons with high efficiencies is expected to open unprecedented applications that are not possible to attain by any other types of neutron detectors.

36 MATERIALS SCIENCE↗

Comparison of SEM and Optical Analysis of DT Neutron Tracks in CR-39 Detectors

A solid state nuclear track detector, CR-39, was exposed to DT neutrons. After etching, the resultant tracks were analyzed using both an optical microscope and a scanning electron microscope (SEM). In this communication, both methods of analyzing DT neutron tracks are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new method to measure the U-235 content in fresh LWR fuel assemblies via fast-neutron passive self-interrogation

The purpose of this paper is to provide a solution to a decades old safeguards problem in the verification of the fissile concentration in fresh light water reactor (LWR) fuel assemblies. The problem is that the burnable poison (e.g. Gd 2 O 3 ) addition to the fuel rods decreases the active neutron assay for the fuel assemblies. This paper presents a new innovative method for the verification of the 235 U linear mass density in fresh LEU fuel assemblies that is insensitive to the burnable poison content. The technique makes use of the 238 U atoms in the fuel rods to self-interrogate the 235 U mass. The innovation for the new approach is that the 238 U spontaneous fission (SF) neutrons from the rods induces fission reactions (IF) in the 235 U that are time correlated with the SF source neutrons. Thus, the coincidence gate counting rate benefits from both the nu-bar of the 238 U SF (2.07) and the 235 U IF (2.44) for a fraction of the IF reactions. Whereas, the 238 U SF background has no time-correlation boost. The higher the detection efficiency, the higher the correlated boost because background neutron counts from the SF are being converted to signal doubles. This time-correlation in the IF signal increases signal/background ratio that provides a good precision for the net signal from the 235 U mass. The hard neutron energy spectrum makes the technique insensitive to the burnable poison loading where a Cd or Gd liner on the detector walls is used to prevent thermal-neutron reflection back into the fuel assembly from the detector. Here, we have named the system the fast-neutron passive collar (FNPC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Laue micro diffraction and neutron diffraction analysis of residual elastic strains and plastic deformation in a 1% uniaxial tensile tested nickel alloy 600 sample

The magnitude and distribution of elastic strain for a nickel alloy 600 (A600) sample that had been subjected to uniaxial tensile stress were measured by micro Laue diffraction (MLD) and neutron diffraction techniques. For a sample that had been dimensionally strained by 1%, both MLD and neutron diffraction data indicated that the global residual elastic strain was on the order of 10{sup -4}, however the micro-diffraction data indicated considerable grain-to-grain variability amongst individual components of the residual strain tensor. A more precise comparison was done by finding those grains in the MLD map that had appropriate <hkl> oriented in the specific directions matching those used in the neutron measurements and the strains were found to agree within the uncertainty. Large variations in strain values across the grains were noted during the MLD measurements which are reflected in the uncertainties. This is a possible explanation for the large uncertainty in the average strains measured from multiple grains during neutron diffraction.

36 MATERIALS SCIENCE↗

Improving the Field Portability of Neutron and Gamma Counting Techniques

Savannah River National Laboratory (SRNL) puts science to work by developing techniques that better meet customers needs for in-situ measurements. There is high demand for laboratory quality measurements in field situations, improving the cost and speed for first responders and environmental monitoring. This work focused on two improvements (1) reading a signal from a neutron detector using a Raspberry Pi (2) testing the Peak-to-Valley method for determining the depth of a source in soil contamination measurements. A Raspberry Pi is a cheap, compact computer. This affordable, compact computer is able to do simple tasks that a desktop computer is able to do, like spreadsheets, browse the internet, play games and even program a simple robot. Additionally, a Raspberry Pi can run off of a battery, so it could be deployed for long term measurements in adverse conditions like neutron monitors deployed in a shipping port. Using the Raspberry Pi and libraries easily accessible on the internet, a code was written in Python that allows the Pi to keep track of how many times a button is pushed. This work will be used with the future goal of creating low power-budget neutron detectors. 1) Make sure Python was correctly installed on the Raspberry Pi. 2) Write a code that will keep track of how many times a button connected to the Pi is pressed. A code was written to use the Raspberry Pi to count the number of times the button was pushed. Moving forward the Raspberry Pi will be tested with a neutron counter. Ideally, each signal from the neutron pulse will be equivalent of 'push the button' and be counted. In the characterization of a soil contamination area both the location and the depth of the source is important. Attenuation of the source by the soil can make determining its depth challenging, particularly for monoenergetic radionuclides like Cs-137. To address this issue, a method of calculating the 'peak-to-valley' ratio of the gamma count spectra is implemented to help calculate the known depth of the source. 1) Determine the 'peak-to-valley' ratio of a Cs-137 source at different depths. 2) Find an appropriate function to serve as a model for the peak-to-valley ratio as a function of depth. Several Petri dishes, filled with sand, were stacked with one containing a Cs-137 source. The individual Petri dishes allowed for the source to be placed at different depths. A bucket was placed over the sand and source, to keep the detector at a consistent height. A Petri dish containing a Eu-155 source, which acted as an internal calibration standard, was placed on top of the bucket. A NaI detector was place on top of the Eu-155 source and the assembly was surrounded by a tungsten shield. Count times were 20 minutes and the data was analyzed using PeakEasy. Data was recorded for Cs-137 at a series of depths in sand. Both exponential and logarithmic functions provided a reasonable fit to the data. The experimental data showed a decreasing 'peak-to-valley' ratio as the depth was increased. The next steps for this project involves determining the optimum fit function and combining the results from sand to different soil types to get a better representation of the soil found at SRS. Eventually, the peak-to-valley ratio will be used to estimate the depth of contamination in field measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delayed Neutrons from Photofission of {sup 238}U at E{sub γ} ≲ 10 MeV

— The technique is described for measuring energy spectra and temporal distributions of delayed neutrons from photofission at the pulsed electron accelerator LUE-8-5 of the Institute for Nuclear Research of the Russian Academy of Sciences (INR RAS). The measurements were performed by the neutron scintillation spectrometer using pulse shape discrimination of background γ-quanta. The results of measurements of {sup 238}U-photofission with the kinetic energy of incident electrons ≈10 MeV are given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Enhanced two-dimensional ferromagnetism in van der Waals β-UTe 3 monolayers

The discovery of local-moment magnetism in van der Waals (vdW) semiconductors down to the single-layer limit has led to a paradigm shift in the understanding of two-dimensional (2D) magnets. The incorporation of strong electronic and magnetic correlations in 2D vdW metals remains a sought-after platform to enable control of emergent quantum phases and to achieve more theoretically tractable microscopic models of complex materials. To date, however, there is limited success in the discovery of such metallic vdW platforms, and f-electron monolayers remain out of reach. Here, we demonstrate that strongly correlated β–uranium tritelluride (β-UTe 3 ) can be exfoliated to the monolayer limit. Unexpectedly, β-UTe 3 remains ferromagnetic in this limit with an enhanced ordering temperature of 35 kelvin, a factor of two larger than its bulk counterpart. Our work establishes β-UTe 3 as a materials platform for investigating and modeling correlated behavior in the monolayer limit and opens numerous avenues for quantum control with, e.g., strain engineering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗