Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

The reactions {sup 25}Mg({alpha},n){sup 28}Si, {sup 26}Mg({alpha},n){sup 29}Si and their possible impact on nucleosynthesis

At the time neon burning is activated in massive stars, large amounts of {sup 25}Mg and {sup 26}Mg have been accumulated from the previous evolutionary phases. In particular, at typical temperatures for neon shell burning, the reactions {sup 25}Mg({alpha},n){sup 28}Si and {sup 26}Mg({alpha},n){sup 29}Si become efficient providing additional neutron fluxes and affecting the nucleosynthesis distribution. Good knowledge of the reaction rates is required to study their effect on nucleosynthesis during neon shell burning conditions (T{sub 9} > or approx. 1.5, where T{sub 9} is the temperature in gigakelvin). At the Nuclear Science Laboratory, University of Notre Dame, IN, USA we developed a neutron detector to investigate the {sup 25}Mg({alpha},n){sup 28}Si and {sup 26}Mg({alpha},n){sup 29}Si reactions as possible neutron sources during neon shell burning. In the present paper we briefly describe the experimental procedures developed to measure those reactions. Finally, we discuss the impact of {sup 25}Mg({alpha},n){sup 28}Si and {sup 26}Mg({alpha},n){sup 29}Si on the s-process nucleosynthesis for the barium isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Diagnostic Components in Harsh Radiation Environments: Possible Overlap in R&D Requirements of IC and MF Systems

The next generation of large scale fusion devices--ITER/LMJ/NIF--will require diagnostic components to operate in environments far more severe than those encountered in present facilities. This harsh environment will be induced by fluxes of neutrons, gamma rays, energetic ions, electromagnetic radiation, and in some cases debris and shrapnel, at levels several orders of magnitude higher than those experienced in today's devices. For several years the question of possible synergy between inertial and the magnetic confinement research has been pursued by members of the respective communities. A first joint workshop specifically devoted to the identification and promotion of these synergies was organized in France, at Aix-en-Provence from June 27th to 29th, 2007. The workshop was attended by about 50 invited specialists. The participants identified a number of subject areas where common overlapping interests could benefit from additional interactions and meetings: windows, optical fibers, mirrors, cables, electronic components and 14 MeV neutron sources. In this paper we summarize the findings of these working groups. We put the discussion into context by including a brief description of the environments and the physical effects that have to be handled.

42 ENGINEERING↗

A spin-echo resolved grazing incidence scattering set-up for the neutron interrogation of buried nanostructures.

We present a dedicated experimental spin-echo resolved grazing incidence scattering (SERGIS) setup for the investigation of surfaces and thin films exhibiting large lateral length scales. This technique uses the neutron spin to encode one in-plane component of the wave-vector transfer in a grazing angle scattering experiment. Instead of the scattering angle, the depolarization of the scattered beam is measured. This allows one to achieve a very high in-plane momentum resolution without collimation of the incident neutron beam in the corresponding direction. SERGIS can therefore offer an alternative or complementary method to conventional grazing incidence neutron scattering experiments. We describe the experimental setup installed at the neutron sources ILL (Grenoble) and FRM II (Garching) and present data obtained with this setup on various samples exhibiting characteristic mesoscopic length scales in the range of several hundred nanometers. We also derive general formulas and error margins for the analysis and interpretation of SERGIS data and apply them to the cases of a one-dimensional structure and of an island morphology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reactivity Coefficient Calculation for a Low-Power LEU Research Reactor

Core design studies on a 20-MW thermal power low enriched uranium (LEU) fueled research reactor are underway at the NIST Center for Neutron Research (NCNR) with the primary purpose of providing quality neutron beams for scientific research. The 'tank-in-pool' design pattern is adopted for the new reactor: A compact core composed of two horizontally split halves are surrounded by a cylindrical D{sub 2}O reflector tank, and the tank is itself surrounded by a large H{sub 2}O pool, which functions as thermal and biological shielding. The split core consists of 18 MTR-type fuel elements which are evenly distributed into two regions. The LEU fuel used in the study is the U{sub 3}Si{sub 2}-Al dispersion fuel with U-235 enrichment of 19.75%, the only NRC certified LEU fuel in the U.S. The core is cooled and moderated by H{sub 2}O, and separated from D{sub 2}O by zircaloy core boxes. Hafnium control blades are utilized as both criticality and safety control elements for the reactor. They are controlled by a mechanical driver located at the bottom of the core but with the fully withdrawn positions at the top of the core. In a standard reactor calculation, it is necessary to evaluate the reactivity coefficient with respect to some physical parameters such as fuel or moderator temperature. For nearly all reactor designs, negative reactivity coefficients are required for safety. As a light-water cooled thermal reactor, the new reactor is designed to work in an under-moderated mode with the most achievable reactivity. The core is required to have negative reactivity coefficients under any normal or abnormal circumstances such as over power transient, loss of coolant or reflector, etc. Therefore the reactivity coefficient addresses reactor safety concerns as well as provides valuable quantitative parameters for reactor safety analyses. In this summary, three typical reactivity coefficients for the low-power LEU core are calculated using the Monte-Carlo code MCNP-6: the moderator temperature coefficient (MTC), the fuel temperature coefficient (FTC), and the void coefficient (VC). A direct perturbation methodology is applied to calculate all these coefficients. The perturbed case is produced by manually perturbing a single physical property with respect to the reference case (the one with normal operational conditions), as the multiplication factor (i.e. k{sub eff}) of the perturbed case is calculated by MCNP. The corresponding reactivity coefficient is thereby determined by dividing the reactivity change over the associated parameter changes. Core design studies are underway at NIST to develop a low-power LEU fueled beam reactor to advance the neutron source capability at NCNR for the next century. The reactivity effect caused by moderator temperature, fuel temperature and void is investigated though a direct perturbation approach using the MCNP code. The MTC, FTC, and VC for a representative startup core is obtained and the negative effect characteristics of these coefficients are observed. The reactivity effects under several postulated abnormal scenarios are also investigated. The overall negative feedback to the reactivity at each situation is confirmed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Distributed Workflows for Modeling Experimental Data

Modeling helps explain the fundamental physics hidden behind experimental data. In the case of material modeling, running one simulation rarely results in output that reproduces the experimental data. Often one or more of the force field parameters are not precisely known and must be optimized for the output to match that of the experiment. Since the simulations require high performance computing (HPC) resources and there are usually many simulations to run, a workflow is very useful to prevent errors and assure that the simulations are identical except for the parameters that need to be varied. These workflows are usually distributed because the simulations require HPC, but the optimization and steps to compare the simulation results and experimental data are done on a local workstation. We will present results from force field refinement of data collected at the Spallation Neutron Source using Kepler, Pegasus, and Beam workflows and discuss what we have learned from using these workflows.

Lynch, Vickie E.↗

Novel, Low-Cost, Light-Weight High Efficiency (H*10 Capable) Neutron Detector-Dosimeter

The goal of this project was to design, develop and validate a novel, spectroscopy enabled H*(10) neutron dosimetry system based on the tensioned metastable fluid detector (TMFD) sensor technology. The project team consisted of staff from Oak Ridge National Laboratory (ORNL), Purdue University (PU) and Sagamore Adams Laboratories, LLC (SAL). PU-SAL staff were tasked with the design, development, construction and testing of the H*TMFD hardware and software, along with developing the control and data acquisition software for comparison of predictions from H*TMFD against a commonly accepted and widely used industry standard system; for this project, the Li-I detector coupled to bonner spheres (LiI-BSS) system manufactured by Ludlum, Inc. was utilized as the reference (“gold”) standard – similar in terms of neutron spectroscopy enablement to another industry recognized, albeit, significantly higher cost (est. $300K) system referred to as “ROSPEC” (from BTI, Inc., which was not available for this project). ORNL staff were tasked with providing field-relevant guidance, apparatus and facilities for acquiring data against calibrated neutron sources, and comparing results of H*TMFD against LiI-BSS system predictions in a series of blind-tests conducted at ORNL. Over the course of 12 months, the PU-SAL-ORNL staff successfully accomplished the proposed technical and administrative tasks, inclusive of engaging in outreach to potential users of this technology in the DOE-wide infrastructure. The proposed tasks were successfully accomplished in timely manner; the follow-up type tasks pertaining to SBIR type Phases 2-3 were discussed and are initiated, inclusive of filing for intellectual property (IP) disclosures and possible patent filings by PU’s Office of Technology Commercialization (OTC). Two H*TMFD system architectures (see Exhibits 1 & 2 in the report) were developed and constructed for hand-portability by health-physicists (HPs) – the HP-H*TMFD, and the H*TMFD system which consists of a side-by-side mounted array of 4 TMFDs of 3 different sizes in sensitive volume (including one with borated fluid) that now simultaneously enables neutron energy spectroscopy: single bin for < 0.1 MeV, and 152 energy bins in the 0.1-15.2 MeV range; H*(10) dosimetry from ~5 μRem/h towards 10 R/h ranges. Several experiments were conducted using neutron sources in various configurations (shielded and unshielded). In direct comparison against the LiI-BSS industry standard (acquiring data for 26h each source), the H*TMFD system (acquiring data for ~6h for each source) offered H*(10) dose predictions for the most part accurate to within +/-10% for dose rates in the 100-300 μRem/h range. The LiI-BSS was impractical to use under ultra-low (~10 μRem/h) dose rate space, as also another metering device used at ORNL (Ludlum 4241L non-spectroscopy enabled) for which the lower limit is set by the manufacturer at 100 μRem/h. The enablement for efficient use in timely manner at the 10 μRem/h levels is deemed to be a strong enabling factor for H*TMFD for use in the DOE-nuclear laboratory arena. In terms of weight, the HP-H*TMFD weighs under ~5-7 lb.; the H*TMFD system weighs ~35-lb. As such, it is ~1/4 the weight of an LiI-BSS system weighing ~120 lb (LiI detector with 6 bonner spheres) and, ~1/2 the weight of ROSPEC. As a result of this activity, two involved post-doctoral student staff have now transitioned their knowledge and experiences to DOE’s Pacific Northwest National Laboratory (PNNL). A PU graduate student has also benefited from this project work which formed a principal basis for his Ph.D. dissertation work (in progress).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A time-dependent neutron transport method of characteristics formulation with time derivative propagation

A new time-dependent Method of Characteristics (MOC) formulation for nuclear reactor kinetics was developed utilizing angular flux time-derivative propagation. This method avoids the requirement of storing the angular flux at previous points in time to represent a discretized time derivative; instead, an equation for the angular flux time derivative along 1D spatial characteristics is derived and solved concurrently with the 1D transport characteristic equation. This approach allows the angular flux time derivative to be recast principally in terms of the neutron source time derivatives, which are approximated to high-order accuracy using the backward differentiation formula (BDF). This approach, called Source Derivative Propagation (SDP), drastically reduces the memory requirements of time-dependent MOC relative to methods that require storing the angular flux. An SDP method was developed for 2D and 3D applications and implemented in the computer code DeCART in 2D. DeCART was used to model two reactor transient benchmarks: a modified TWIGL problem and a C5G7 transient. The SDP method accurately and efficiently replicated the solution of the conventional time-dependent MOC method using two orders of magnitude less memory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetism reflectometer study shows LiF layers improve efficiency in spin valve devices

New, more efficient materials for spin valves - a device used in magnetic sensors, random access memories, and hard disk drives - may be on the way based on research using the magnetism reflectometer at Oak Ridge National Laboratory (ORNL). Spin valve devices work by means of two or more conducting magnetic material layers that alternate their electrical resistance depending on the layers alignment. Giant magnetoresistance is a quantum mechanical effect first observed in thin film structures about 20 years ago. The effect is observed as a significant change in electrical resistance, depending on whether the magnetization of adjacent ferromagnetic layers is in a parallel or an antiparallel magnetic alignment. 'What we are doing here is developing new materials. The search for new materials suitable for injecting and transferring carriers with a preferential spin orientation is most important for the development of spintronics,' said Valeria Lauter, lead instrument scientist on the magnetism reflectometer at the Spallation Neutron Source (SNS), who collaborated on the experiment. The researchers discovered that the conductivity of such materials is improved when an organic polymer semiconductor layer is placed between the magnetic materials. Organic semiconductors are now the material of choice for future spin valve devices because they preserve spin coherence over longer times and distances than conventional semiconductors. While research into spin valves has been ongoing, research into organic semiconductors is recent. Previous research has shown that a 'conductivity mismatch' exists in spin valve systems in which ferromagnetic metal electrodes interface with such organic semiconductors as Alq3 ({pi}-conjugated molecule tris(8-hydroxy-quinoline) aluminium). This mismatch limits the efficient injection of the electrons from the electrodes at the interface with the semiconductor material. However, lithium fluoride (LiF), commonly used in light-emitting diodes, has been found to enhance the injection of electrons through the semiconductor. Researchers from the University of Alabama and ORNL used polarized neutrons at the magnetism reflectometer at SNS to investigate the electronic, magnetic, and structural properties of the electrodes in a novel system. In this system, the magnetic layers cobalt and Ni{sub 80}Fe{sub 20} are interfaced with spacer layers composed of the organic semiconductor Alq3. A coupling layer of LiF is inserted to separate the magnetized layers from the semiconductor. 'ALQ3 is an organic semiconductor material,' said Lauter. 'Normally in these systems a first magnetic layer is grown on a hard substrate so that one can get the controlled magnetic parameters. Then you grow the organic semiconductor layer, followed by another magnetic material layer, such as cobalt.' In addition to determining the effect of the LiF layers on the efficiency of the electron injection, the researchers wanted to determine the magnetic properties of the cobalt and Ni{sub 80}Fe{sub 20} as well as the interfacial properties: whether there is interdiffusion of cobalt through the LiF layer to the semiconductor, for example. The researchers used polarized neutrons at beam line 4A to probe the entire, layer-by-layer assembly of the system. 'Reflectometry with polarized neutrons is a perfect method to study thin magnetic films,' Lauter said. 'These thin films - if you put one on a substrate, you see it just like a mirror. However, this mirror has a very complicated internal multilayer structure. The neutrons look inside this complicated structure and characterize each and every interface. Due to the depth sensitivity of the method, we measure the structural and magnetic properties of each layer with the resolution of 0.5 nm. The neutron scattering results found that inserting LiF as a barrier significantly improves the quality of the interface, increasing the injection of electrons from the magnetic layer through the organic semiconductor in the spin valve and enhancing the overall properties of the system. In related work the magnetic properties of the cobalt film and the permalloy Ni{sub 80}Fe{sub 20} were characterized. Cobalt in particular needed attention, as it cannot be grown epitaxially (i.e., deposited) on an organic semiconductor film. Cobalt becomes polycrystalline or amorphous, and this affects its magnetic properties. The data from the first experiment showed that the cobalt layer in the system 'did not have typical magnetic properties,' Lauter said. 'The results showed that the cobalt had low magnetization. To improve the efficiency, the cobalt magnetization should be much higher. So this experiment helped us to improve the growth conditions and to get a cobalt layer with better magnetic properties.' In a subsequent experiment the researchers increased the magnetization of the cobalt, and a follow-up paper is in progress.

36 MATERIALS SCIENCE↗

Next-generation diamond cell and applications to single-crystal neutron diffraction

In this paper, a diamond cell optimized for single-crystal neutron diffraction is described. It is adapted for work at several of the single-crystal diffractometers of the Spallation Neutron Source and the High Flux Isotope Reactor at the Oak Ridge National Laboratory (ORNL). A simple spring design improves portability across the facilities and affords load maintenance from offline pressurization and during temperature cycling. Compared to earlier prototypes, pressure stability of polycrystalline diamond (Versimax®) has been increased through double-conical designs and ease of use has been improved through changes to seat and piston setups. These anvils allow ~30%-40% taller samples than possible with comparable single-crystal anvils. Hydrostaticity and the important absence of shear pressure gradients have been established with the use of glycerin as a pressure medium. Large single-crystal synthetic diamonds have also been used for the first time with such a clamp-diamond anvil cell for pressures close to 20 GPa. The cell is made from a copper beryllium alloy and sized to fit into ORNL’s magnets for future ultra-low temperature and high-field studies. Finally, we show examples from the Spallation Neutron Source’s SNAP and CORELLI beamlines and the High Flux Isotope Reactor’s HB-3A and IMAGINE beamlines.

36 MATERIALS SCIENCE↗

Compact spherical neutron polarimeter using high-T{sub c} YBCO films

We describe a simple, compact device for spherical neutron polarimetry measurements at small neutron scattering angles. The device consists of a sample chamber with very low (<0.01 G) magnetic field flanked by regions within which the neutron polarization can be manipulated in a controlled manner. This allows any selected initial and final polarization direction of the neutrons to be obtained. We have constructed a prototype device using high-T{sub c} superconducting films and mu-metal to isolate regions with different magnetic fields and tested device performance in transmission geometry. Finite-element methods were used to simulate the device’s field profile and these have been verified by experiment using a small solenoid as a test sample. Measurements are reported using both monochromatic and polychromatic neutron sources. The results show that the device is capable of extracting sample information and distinguishing small angular variations of the sample magnetic field. As a more realistic test, we present results on the characterization of a 10 μm thick Permalloy film in zero magnetic field, as well as its response to an external magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NPDGamma: A Measurement of the Parity-Violating Gamma Asymmetry A in n-p Capture

The NPDGamma Experiment measures the parity-violating correlation A{sub {Gamma}Y} between neutron spin and photon momentum in the reaction {rvec n} + p {yields} d + {gamma}. Knowledge of A{sub {Gamma}Y} and other parity-violating observables in few-body nuclear systems will provide constraints for a parameterized description of {Delta}S = 0 parity-violating phenomena free from complications of nuclear structure. The NPDGamma experiment uses a polarized cold pulsed neutron beam, a liquid parahydrogen target, and a cylindrical array of 48 CsI(Tl) scintillation detectors operated in current mode to search for the asymmetry. NPDGamma recently completed the first phase of the program to measure A{sub {Gamma}Y} at the Los Alamos Neutron Science Center with the preliminary result A{sub {Gamma}Y} = (-1.2 {+-} 2.1(stat.) {+-} 0.1(sys.)) x 10{sup -7}, reproducing the previous upper limit from a measurement at a reactor facility. We discuss the theoretical background and experimental method and report on preliminary analysis of the LANSCE data. The second phase of the program to measure A{sub {Gamma}Y} is in progress at the Spallation Neutron Source at Oak Ridge National Laboratory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

J lich Neutron Spin Echo Instrument Inaugurated

The neutron spin echo (NSE) spectrometer was inaugurated by the Forschungszentrum Juelich at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) on November 2-5, 2009. The focus of the NSE spectrometer is soft-matter research, and its capabilities make it useful for other fields of modern condensed matter and materials science. The instrument is especially suited for analyzing slow dynamical processes and will enable increased understanding of molecular motion at nano- and mesoscopic levels. It will be a world-class spectrometer in both resolution and dynamic range, with a goal of six orders of magnitude (from 1 ps to 1 {mu}s) is anticipated using wavelengths between 0.25 < {lambda}/nm < 2.0 and a unique correctable field integral of 1 Tm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Development of a Parameterized Scatter Removal Algorithm for NMIS Imaging

Neutron radiography is a powerful investigative technique for analyzing the interior structure of an object. If the true attenuation of neutrons at each position in the object can be measured, the cross-sections can be computed using the exponential attenuation formula. However, scattered neutrons will contribute to the measured neutron flux and reduce the measured attenuation. The Nuclear Materials Identification System (NMIS) uses a time-tagged and electronically collimated DT neutron source to reduce this effect; however, some of the scattering component remains. This work used Monte Carlo simulations to calculate the scattering component for a variety of scenarios. The scattering for each scenario was fit using a Gaussian distribution to derive a point scatter function. These point scatter functions were used to develop a parameterized scatter removal algorithm that can calculate and remove the scattering component for a wide range of scenarios based on operator inputs. The process used to calculate the scatter functions and develop the scatter removal algorithm is discussed in detail. Examples of simulated and experimental measurements are used to test and validate the algorithm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prompt Gamma Neutron Activation Analysis of Niobium for Characterization of Light Interstitials

High purity niobium metal is used in the construction of superconducting radio frequency (SRF) cavities in superconducting particle accelerators. The Spallation Neutron Source at Oak Ridge National Laboratory is an example of an SRF linear accelerator (LINAC) that requires this high purity niobium material. For the SRF cavities to function well, it is necessary that the cavity wall have a high thermal conductivity so that the radio frequency (RF) power can be dissipated into the liquid helium coolant. For a high thermal conductivity of the niobium metal to be achieved, it is required to have extremely low levels of impurities. The current industry standard for determining the quality of the high purity niobium material is the residual resistivity ratio (RRR) technique. In this technique, the temperature dependency of a niobium metal sample is determined at temperatures near that of liquid helium in order to establish where the superconducting jump occurs. With this method, it is possible to find the general level of impurity of the metal sample, but not the specific elements that are contributing to the impurity. The impurities that are of particular interest to manufacturers of niobium for SRF use are tantalum and light interstitials, such as hydrogen, carbon, nitrogen, and oxygen. In this research, we focus on determining the analytical sensitivity of the detector system and characterizing the light interstitial content in high purity niobium metal through the use of Prompt Gamma Neutron Activation Analysis (PGNAA). PGNAA is an analytical technique that can be utilized to determine the concentration of elemental components in a wide variety of materials with high precision and reproducibility. In this process, neutrons bombard a sample material, causing the emission of gamma rays from the sample. Each element emits a unique spectrum of gamma radiation, which allows for identification of the elements present in the sample. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of keV-Neutron Capture Gamma Rays for Se Isotopes

Neutron capture gamma rays were measured for all stable Se isotopes in an incident neutron energy region from 15 to 100 keV. A neutron time-of-flight method was adopted with a ns-pulsed neutron source based on the {sup 7}Li(p,n){sup 7}Be reaction and with a large anti-Compton NaI(Tl) spectrometer. A pulse-height weighting technique was applied to the observed capture gamma-ray pulse-height spectra to obtain the capture yields. Using the standard capture cross sections of {sup 197}Au, the capture cross sections of stable Se isotopes were derived with an error of about 5%. The capture gamma-ray spectra were obtained by unfolding the observed capture gamma-ray pulse-height spectra. The present results for the capture cross sections are compared with the previous measurements and the evaluations of JENDL-3.3 and ENDF/B-VI.8 and VII.0.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detector positioning for the initial subcriticality level determination in accelerator-driven systems

Within the GUINEVERE project (Generation of Uninterrupted Intense Neutrons at the lead Venus Reactor) carried out at SCK-CEN in Mol, the continuous deuteron accelerator GENEPI-3C was coupled to the VENUS-F fast simulated lead-cooled reactor. Today the FREYA project (Fast Reactor Experiments for hYbrid Applications) is ongoing to study the neutronic behavior of this Accelerator Driven System (ADS) during different phases of operation. In particular the set-up of a monitoring system for the subcriticality of an ADS is envisaged to guarantee safe operation of the installation. The methodology for subcriticality monitoring in ADS takes into account the determination of the initial subcriticality level, the monitoring of reactivity variations, and interim cross-checking. At start-up, the Pulsed Neutron Source (PNS) technique is envisaged to determine the initial subcriticality level. Thanks to its reference critical state, the PNS technique can be validated on the VENUS-F core. A detector positioning methodology for the PNS technique is set up in this paper for the subcritical VENUS-F core, based on the reduction of higher harmonics in a static evaluation of the Sjoestrand area method. A first case study is provided on the VENUS-F core. This method can be generalised in order to create general rules for detector positions and types for full-scale ADS. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Neutron Studies of Tb2Mo2O7

We have used the new high energy resolution spectrometer (BaSiS), at the Spallation Neutron Source in Oak Ridge, to conclusively prove the existence of a low energy mode at 0.34(1) meV in the spin glass Tb{sub 2}Mo{sub 2}O{sub 7}. This mode is reminiscent of the excitation observed in the ordered phases of both Tb{sub 2}Ti{sub 2}O{sub 7} and Tb{sub 2}Sn{sub 2}O{sub 7}. The dynamical nature of the transition seen in the magnetization at {approx} 25 K suggests that this frustrated magnet shows a dynamic crossover between a high-temperature phase of poorly correlated, quickly relaxing spins to a low-temperature regime with much slower, short ranged spin correlations extending no further than to the next nearest neighbor. Existing theories explain the spin glass transition in terms of a phase transition and order parameters, and assume the existence of a distinct spin glass phase. There is no evidence for such a phase in Tb{sub 2}Mo{sub 2}O{sub 7}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analytical expressions for the gate utilization factors of passive multiplicity counters including signal build-up

In the realm of nuclear safeguards, passive neutron multiplicity counting using shift register pulse train analysis to nondestructively quantify Pu in product materials is a familiar and widely applied technique. The approach most commonly taken is to construct a neutron detector consisting of {sup 3}He filled cylindrical proportional counters embedded in a high density polyethylene moderator. Fast neutrons from the item enter the moderator and are quickly slowed down, on timescales of the order of 1-2 {micro}s, creating a thermal population which then persists typically for several 10's {micro}s and is sampled by the {sup 3}He detectors. Because the initial transient is of comparatively short duration it has been traditional to treat it as instantaneous and furthermore to approximate the subsequent capture time distribution as exponential in shape. With these approximations simple expressions for the various Gate Utilization Factors (GUFs) can be obtained. These factors represent the proportion of time correlated events i.e. Doubles and Triples signal present in the pulse train that is detected by the coincidence gate structure chosen (predelay and gate width settings of the multiplicity shift register). More complicated expressions can be derived by generalizing the capture time distribution to multiple time components or harmonics typically present in real systems. When it comes to applying passive neutron multiplicity methods to extremely intense (i.e. high emission rate and highly multiplying) neutron sources there is a drive to use detector types with very fast response characteristics in order to cope with the high rates. In addition to short pulse width, detectors with a short capture time profile are also desirable so that a short coincidence gate width can be set in order to reduce the chance or Accidental coincidence signal. In extreme cases, such as might be realized using boron loaded scintillators, the dieaway time may be so short that the build-up (thermalization transient) within the detector cannot be ignored. Another example where signal build-up might be observed is when a {sup 3}He based system is used to track the evolution of the time correlated signal created by a higher multiplying item within a reflective configuration such as the measurement of a spent fuel assembly. In this work we develop expressions for the GUFs which include signal build-up.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗