Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Evaluation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

The Data Quality Monitoring Software for the CMS experiment at the LHC: past, present and future

The Data Quality Monitoring software is a central tool in the CMS experiment. It is used in the following key environments: (i) Online, for real-time detector monitoring; (ii) Offline, for the prompt-offline-feedback and final fine-grained data quality analysis and certification; (iii) Validation of all the reconstruction software production releases; (iv) Validation in Monte Carlo productions. Though the basic structure of the Run1 DQM system remains the same for Run2, between the Run1 and Run2 periods, the DQM system underwent substantial upgrades in many areas, not only to adapt to the surrounding infrastructure changes, but also to provide improvements to meet the growing needs of the collaboration with an emphasis on more sophisticated methods for evaluating data quality. We need to cope with the higher-energy and -luminosity proton-proton collision data, as well as the data from various special runs, such as Heavy Ion runs. In this contribution, we will describe the current DQM software, structure and workflow in the different environments. We then discuss the performance and our experiences with the DQM system in Run2. The main technical challenges which we have encountered and the solutions adopted during Run2 will also be discussed, including efficient use of memory in multithreading environments. Finally, we present the prospect of a future DQM upgrade with emphasis on functionality and long-term robustness for LHC Run3.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical Investigation of the Electrical Resistivity Tomography for Detecting the Waste Zone beneath an Engineered Surface - 19066

Surface barriers are an integral part of waste site remediation that are needed to minimize further contamination spread, allow time for additional radionuclide decay, and decrease risks to workers and the environment. Depending on the type of waste, the design life of a surface barrier varies from decades to millennia. The performance and impacts of surface barriers must be monitored beyond the life of most monitoring instruments; hence, long-term monitoring technologies are needed that can non-intrusively assess barrier impacts both in the near surface and to large depths. Innovative geophysical methods such as the electrical resistivity tomography (ERT) are capable of nonintrusively detecting the distribution of soil wetness and/or contaminant plumes in the soil. However, the application of geophysical methods in monitoring a surface barrier system has been very limited because a surface barrier is often composed of multiple components made of natural (e.g., soil, rocks, asphalt) and manufactured (e.g., plastic, metal) materials. In this study, the E4D numerical simulator, developed at Pacific Northwest National Laboratory for inverting the ERT survey data, was used to evaluate the configuration of electrodes for optimized ERT monitoring of waste zone below a surface barrier. The results indicate that, for high-quality mapping of the conditions below the surface barrier, the ERT method requires that some of the electrodes be installed either beneath the surface barrier or in boreholes around the barrier. In reality, for a surface barrier that is being constructed, some electrodes may be installed beneath the non-conductive layer of the surface barrier before or during barrier construction. For a surface barrier that has already been constructed, some electrodes can be installed in a few vertical boreholes around the barrier boundary. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Opportunities to Implement Solutions to Achieve Remedial Action Objectives in Consideration of Stakeholder Interests - 20365

A case study in the implementation of a soils excavation and removal project conducted at a Formerly Utilized Sites Remedial Action Program (FUSRAP) Maywood Superfund Site (FMSS) vicinity property; an active commercial business, in a densely populated area, with significant operational, technical and, logistical constraints that were expected to limit areas that could be remediated. The United States Army Corps of Engineers-led (USACE) team successfully navigated complex overlapping stakeholder interests to achieve a more efficient and complete removal of contaminated soils and debris while minimizing unnecessary excess costs to the Government. This paper centers on FUSRAP activities at the FMSS vicinity property located at 149-151 Maywood Avenue, Maywood, Bergen County, New Jersey. For most of its FUSRAP history, this ∼109,000 square meter (27-acre) property housed a now-demolished ∼26,000 square meter (6.5-acre) warehouse operated by Sears Logistics Services, a unit of the Sears Roebuck Company (Figure 2). Sears ended its property lease and vacated the warehouse in December 2016. Given that long history and for the purposes of this paper, the property will be referred to as the 'Sears property' or simply 'the property.' The Sears property is approximately 109,000 square meters (27-acres) and is currently zoned for commercial use. The property is bound to the north and northwest by 100 West Hunter Avenue (the Stepan Company), to the northeast by 205 Maywood Avenue, to the east by Maywood Avenue, to the south by 23 West Howcroft Road, and to the west by businesses on NJ Route 17 and the NJ Route 17 roadway. Until December 2016, the property housed a warehouse and distribution center operated by Sears Logistical Services. On-site structures were demolished by the property owner in 2017. The warehouse covered the north section of the property along the Stepan Company property line. A railroad spur from the adjacent property now known as the Maywood Interim Storage Site (MISS) ended at the northeast corner of the warehouse. Wetlands were located east of the warehouse; the rest of the property was covered with paved parking lots and grassed areas. During remediation at the property, opportunities frequently arose where the project team was able to coordinate effectively with stakeholders to sequence remediation activities to facilitate removal of otherwise inaccessible soils and identify opportunities for materials reuse when supported by residual radiological and chemical levels. Some specific opportunities include: - remediating individual truck loading dock bays to maintain tenant operations; - working along a busy highway and in a utility corridor containing a 30-inch high pressure gas main; - remediating Lodi Brook and associated wetlands requiring bypass pumping and other diversionary structures to maintain local community stormwater drainage; - protecting during remediation and supporting access to facilitate tenant/owner maintenance of critical fire protection and water supply system service lines buried in contaminated soils and necessary for safe warehouse operations; and - coordinating with stakeholders to ensure non-radiological contaminants of concern for the site (unaffiliated with FUSRAP) were addressed by the responsible party in a manner that maximized benefit to all parties while supporting an efficient overall site remediation program. Once the property was vacant and the warehouse structure and radiologically non-impacted above-grade structures were demolished, the project identified an opportunity to significantly reduce the volume of waste associated with the foundation of the former warehouse, a foundation suspected of being partially constructed in radiologically contaminated soils. The project developed and implemented supplemental radiological verification survey and sampling strategies based on radiological cross-contamination risk potential with process flow-charts and screening-level based decision points; a program that classified saw-cut sections of concrete based on observed residual surface radioactivity conditions using a combination of gamma sensitive sodium-iodide scans and beta sensitive Geiger-Muller direct measurements. The proposed approach was reviewed with stakeholders with feedback, including consideration of applicable State of New Jersey Site Remediation Program criteria and guidance before implementation. Once classified, additional sampling was performed at frequencies driven by screening. The sampling methods, stockpile sampling frequencies, criteria and, approach to data evaluation were developed in consideration of existing site cleanup standards, regional background ranges, State of New Jersey radiological remediation program guidance, and specific stakeholder input With the property remediation and survey efforts nearly completed, it is relevant to examine retrospectively the objectives, assumptions and limitations in the remedial design (i.e., what was planned) versus what was able to be accomplished through effective teaming. Benefits to other environmental remediation site programs include better understanding of how to work effectively with stakeholders to achieve win-win outcomes, and approaches to site remediation, waste minimization and materials reuse that were successful in their overall outcomes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recurrence of Lower Urinary Tract Symptoms Following Prostate Artery Embolization for Benign Hyperplasia: Single Center Experience Comparing Two Techniques

PurposeTo compare recurrence of lower urinary tract symptoms (LUTS) recurrence at 12 months following original prostate artery embolization (oPAE) or “proximal embolization first, then embolize distal” (PErFecTED) PAE for benign prostatic hyperplasia (BPH).Materials and Methods105 consecutive patients older than 45 years, with prostate size greater than 30 cm{sup 3}, International Prostate Symptom Score (IPSS) ≥ 8, quality of life (QoL) index ≥ 3, and refractory status or intolerance of medical management were prospectively enrolled between June 2008 and August 2013. The study was IRB-approved, and all patients provided informed consent. Patients underwent oPAE or PErFecTED PAE and were followed for at least 12 months. Technical success was defined as bilateral embolization and clinical success (non-recurrence) was defined as removal of the Foley catheter in patients with urinary retention, IPSS < 8 and QoL index < 3 at 12 months of follow-up. Nonparametric statistics were used to compare the study groups due to the size of the study population and distributions of clinical data.Results97 patients had 12-month data and were categorized as oPAE without recurrence (n = 46), oPAE with recurrence (n = 13), PErFecTED without recurrence (n = 36), or PErFecTED with recurrence (n = 2). Recurrence was significantly more common in oPAE patients (χ{sup 2}, p = 0.026). Unilateral embolization was significantly associated with recurrence among patients who underwent oPAE (χ{sup 2}, p = 0.032).ConclusionsBoth oPAE and PErFecTED PAE are safe and effective methods for treatment of LUTS, but PErFecTED PAE is associated with a significantly lower rate of symptom recurrence.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-group Examination of Nickel-Reflected HEU System [Slides]

Researchers noted an unusually large bias for 8-in. nickel reflected HEU sphere in HMF-003 between the 252- group library and the CE library in SCALE 6.2.4. The bias was investigated by reviewing reactions that $k_{eff}$ is sensitive to using TSUNAMI and collecting reaction rate data using tools within SCALE. For this system, bias is primarily due to the elastic scattering in nickel. Researchers compared new multigroup structures in SCALE 6.3. For this system, reduction in CE-to-MG bias seen in the 302-group and further improved in the 1597-group structure. When researchers compared ENDF/B-VIII.0 in SCALE 6.3, library showed improved results with new nickel evaluation. However, the MG-to-CE bias can still be large as large biases can occur in any system. This example highlights the importance of validating results with measured systems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

On Integral Benchmarks for Resolving TSL Conflicts for ENDF/B-VIII.1 Release [Slides]

This presentation touches on polystyrene ORNL evaluation in TSL review process for ENDF/B-VIII.1. the presentation found excellent agreement with INS and transmission measurements. Additionally, PS and PE evaluations with different phonon spectra, similar total xs., calculate keff similarly. This presentation found for critical benchmarks. While extremely useful for validation of nuclear data at all energies, critical benchmarks are not the best tool to provide a definitive answer on conflicting TSLs. In conclusion this presentation found INS and transmission measurements need to be the basis of validation of TSLs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Algorithmic Improvements for Portable Event-Based Monte Carlo Transport Using the Nvidia Thrust Library

High performance computing environments are progressively moving towards many-core computing architectures. The Los Alamos National Laboratory Trinity machine, available in late 2016, will use both Intel Xeon Haswell processors and Intel Xeon Phi Knights Landing many integrated core (MIC) coprocessors. The Lawrence Livermore National Laboratory Sierra machine, available in 2018, will use an IBM PowerPC architecture along with Nvidia graphics processing units (GPUs). Applications that must work in this supercomputing environment must continue to adapt in order to take advantage of the diverse hardware architectures that are coming. A significant consideration is not only the performance of the application on a given platform but also the portability of the application to other platforms. The algorithmic improvements presented in this paper build upon recently-reported work on event-based Monte Carlo transport in the ALPSMC code that models particle transport in one-dimensional binary stochastic media. That paper discussed the lack of available vectorization in the traditional history-based algorithm used for Monte Carlo transport and presented a data parallel event-based algorithm implemented using the Nvidia Thrust library for portability. The performance of the data parallel event-based algorithm implemented using Thrust was compared to a native CUDA implementation. The conclusions from that work were that the Thrust library abstraction technique caused too significant a loss in performance but that the event-based method was a viable option that should be further investigated. In this paper, we describe algorithmic improvements to the data parallel event-based algorithm previously presented. We made further algorithmic optimizations to the event-based CUDA implementation, most notably: data structure changes, a new conditional particle removal scheme in the event-based process, and the use of multiple GPUs. In addition to improvements to the algorithm, we re-implemented the Thrust version from the now further optimized CUDA version, giving a greater chance for success at a performant abstraction. Finally, we revisited our previous assumptions about the inability of the history-based method to achieve performance on vector style architectures such as the MICs and GPUs, with surprising and promising results. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhanced detection of paramagnetic fluorine-19 magnetic resonance imaging agents using zero echo time sequence and compressed sensing

Fluorine-19 ( 19 F) magnetic resonance imaging (MRI) is an emerging technique offering specific detection of labeled cells in vivo. Lengthy acquisition times and modest signal-to-noise ratio (SNR) makes three-dimensional spin-density–weighted 19 F imaging challenging. Recent advances in tracer paramagnetic metallo-perfluorocarbon (MPFC) nanoemulsion probes have shown multifold SNR improvements due to an accelerated 19 F T 1 relaxation rate and a commensurate gain in imaging speed and averages. However, 19 F T 2 -reduction and increased linewidth limit the amount of metal additive in MPFC probes, thus constraining the ultimate SNR. To overcome these barriers, we describe a compressed sampling (CS) scheme, implemented using a “zero” echo time (ZTE) sequence, with data reconstructed via a sparsity-promoting algorithm. Our CS-ZTE scheme acquires k-space data using an undersampled spherical radial pattern and signal averaging. Image reconstruction employs off-the-shelf sparse solvers to solve a joint total variation and -norm regularized least square problem. To evaluate CS-ZTE, we performed simulations and acquired 19 F MRI data at 11.7 T in phantoms and mice receiving MPFC-labeled dendritic cells. For MPFC-labeled cells in vivo, we show SNR gains of ~6.3 × with 8-fold undersampling. We show that this enhancement is due to three mechanisms including undersampling and commensurate increase in signal averaging in a fixed scan time, denoising attributes from the CS algorithm, and paramagnetic reduction of T 1 . Importantly, 19 F image intensity analyses yield accurate estimates of absolute quantification of 19 F spins. Overall, the CS-ZTE method using MPFC probes achieves ultrafast imaging, a substantial boost in detection sensitivity, accurate 19 F spin quantification, and minimal image artifacts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for Measuring Dry Density of Compacted Bentonite Mixture Soil Using 3D Laser Scanner data - 19119

The bentonite mixture soil is planned to be used for the low-permeability layer of low-level radioactive waste (LLW) disposal facilities. The construction of the bentonite mixture soil is similar to that of normal soil construction, and the rolling pressure and/or vibration compaction are used. The quality control of construction is the same as normal soil work, and the construction management has to confirm that the compaction degree (that is ratio of the dry density to the modified proctor curve) is above specified value. As a method of measuring the dry density after construction, the conventional methods are the core cutter method and the sand replacement method. The measurement principle of these methods is simple and the reliability of the measurement value is high, but during measurements digging holes disturb the construction place, and the measurement duration is a disadvantage in these methods. Therefore, we developed a non-destructive method that can make measurements in a short time. The developed method uses the correlation between the density change and the layer thickness change before and after compaction, and estimates the density after compaction from the height change obtained from the survey results. However, since the material is compressed while the cross-sectional area spreads, this cross-sectional area change is also taken into consideration. By using the point cloud data of the 3D laser scanner surveying, it is possible to obtain almost continuous data in a short period of time. Corrected dry density values calculated by the above procedure ρ'{sub 3D} are generally consistent with dry density after compaction ρ{sub core} by the core cutter method. This method differs depending on the boundary conditions of the bottom and the side of the construction place. Then, the reliability of the method was evaluated by applying it to two boundary conditions and comparing it with the core cutter method. The proposed estimation method showed good agreement with the core cutter method. Therefore, it was confirmed that it is possible to estimate dry density with high reliability. Although this method needs to be used in set with core cutter method, the measurement frequency of the core cutter method can be reduced, and the measurement of a vast area can be done in a short time without disturbance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stochastically estimated covariance matrices for independent and cumulative fission yields in the ENDF/B-VIII.0 and JEFF-3.3 evaluations

A Monte-Carlo method for the generation of correlation and covariance matrices for independent and cumulative fission yields has been developed. The method uses a constrained Monte-Carlo resampling structure in order to vary evaluated fission yield libraries in a way that meets basic conservation principles. This results in the generation of correlation/covariance matrices with limited model bias and uncertainty; the matrices are primarily reflective of the evaluated fission yield uncertainties and correlations that arise from the evaluation process. This method has been applied to generate correlation and covariance matrices for all of the fissioning systems of the ENDF/B-VIII.0 and JEFF-3.3 evaluations, marking the first time such matrices have been generated for all of these systems. These covariance matrices have been published online for immediate public use. These correlation and covariance matrices can be used to improve uncertainty estimation in calculations of reactor antineutrino emission rates, decay heat problems, and nuclear forensics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Investigation of practical initial attenuation image estimates in TOF-MLAA reconstruction for PET/MR

Purpose: Time-of-flight joint attenuation and activity positron emission tomography reconstruction requires additional calibration (scale factors) or constraints during or post-reconstruction to produce a quantitative μ-map. In this work, the impact of various initializations of the joint reconstruction was investigated, and the initial average mu-value (IAM) method was introduced such that the forward-projection of the initial μ-map is already very close to that of the reference μ-map, thus reducing/minimizing the offset (scale factor) during the early iterations of the joint reconstruction. Consequently, the accuracy and efficiency of unconstrained joint reconstruction such as time-of-flight maximum likelihood estimation of attenuation and activity (TOF-MLAA) can be improved by the proposed IAM method. Methods: 2D simulations of brain and chest were used to evaluate TOF-MLAA with various initial estimates which include the object filled with water uniformly (conventional initial estimate), bone uniformly, the average μ-value uniformly (IAM magnitude initialization method), and the perfect spatial μ-distribution but with a wrong magnitude (initialization in terms of distribution). 3D GATE simulation was also performed for the chest phantom under a typical clinical scanning condition, and the simulated data were reconstructed with a fully corrected list-mode TOF-MLAA algorithm with various initial estimates. The accuracy of the average μ-values within the brain, chest, and abdomen regions obtained from the MR derived μ-maps was also evaluated using computed tomography μ-maps as the gold-standard. Results: The estimated μ-map with the initialization in terms of magnitude (i.e., average μ-value) was observed to reach the reference more quickly and naturally as compared to all other cases. Both 2D and 3D GATE simulations produced similar results, and it was observed that the proposed IAM approach can produce quantitative μ-map/emission when the corrections for physical effects such as scatter and randoms were included. The average μ-value obtained from MR derived μ-map was accurate within 5% with corrections for bone, fat, and uniform lungs. Conclusions: The proposed IAM-TOF-MLAA can produce quantitative μ-map without any calibration provided that there are sufficient counts in the measured data. For low count data, noise reduction and additional regularization/rescaling techniques need to be applied and investigated. The average μ-value within the object is prior information which can be extracted from MR and patient database, and it is feasible to obtain accurate average μ-value using MR derived μ-map with corrections as demonstrated in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Report on the Integration of Experimental and Modeling Data for Initial Equivalence Study of Microstructural Evolution in Irradiated LPBF 316SS

Advanced materials and manufacturing technologies are poised to improve the safety and design characteristics of nuclear technologies and meet US energy, environmental, and economic needs. In particular, metal additive manufacturing (AM) provides an opportunity to produce novel materials and component geometries, but their use is not without hurdles arising from the inherent microstructure variability that can result from the layer-by-layer build approach. Given the greater possible microstructure variability in AM materials—and the dearth of materials test reactors—it is impractical to rely solely on neutron irradiation studies to produce data for materials qualification for every possibility. This work within the Advanced Materials and Manufacturing Technologies (AMMT) Environmental Effects technical area contributes to the rapid qualification framework by developing a science-driven framework for the accelerated qualification of materials for nuclear environments. A key product of the Environmental Effects technical area of the AMMT program is the Licensing Approach with Ions and Neutrons (LAIN). This approach recognizes that whether using existing materials in new environments, newly developed materials tailored for these environments, or new manufacturing methods, the traditional decades-long approach for materials qualification does not facilitate rapid deployment. In FY 2023, the AMMT program presented a conceptual framework of specific steps to fulfill several technical challenges associated with qualifying materials for performance in radiation environments on an accelerated time frame informed by the state of the art in materials science and a review of the current regulatory landscape. The objective of this section of the Environmental Effects technical area is to critically evaluate and refine the proposed qualification framework presented under AMMT by integrating the research results of the neutron irradiations, the ion irradiations, and modeling efforts. These ongoing efforts span across Argonne National Laboratory (ANL), Idaho National Laboratory (INL), and Oak Ridge National Laboratory (ORNL) and are closely coordinated.

36 MATERIALS SCIENCE↗

Initial Application of TSUNAMI for Validation of Advanced Fuel Systems

A number of advanced reactor concepts and accident-tolerant fuels (ATFs) are under development or in the initial stages of deployment and testing in the nuclear power industry. Many of these concepts incorporate chemical or material forms that have not traditionally been used in the nuclear industry and may present challenges for nuclear criticality safety validation. Sensitivity/uncertainty methods are ideally suited for assessing the applicability of existing critical experiments to these potentially challenging applications. This paper presents two case studies recently completed at Oak Ridge National Laboratory (ORNL) which investigated the use of the TSUNAMI tools within the SCALE code system to perform such assessments.Many advanced reactor concepts include uranium enrichments above 5 wt% 235U but below the 20 wt% limit of low-enriched uranium (LEU). This material, referred to as high assay LEU (HA-LEU), poses difficulties across the entire infrastructure of nuclear power, including enrichment, transportation, fabrication, and storage. A potentially representative transportation package was selected to perform a criticality safety validation assessment for UF6 containing HA-LEU. Sensitivity data were generated using the TSUNAMI-3D sequence, and an assessment of the applicability of a range of critical experiments was performed using the TSUNAMI-IP tool. The critical experiments were drawn from the set of available sensitivity data files distributed with the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. The results indicate that a sufficient number of available experiments may be available to perform validations for these systems.Many different cladding materials and fuel dopants are included in ATFs to mitigate the consequences of a loss of coolant accident. Some of these systems have already been fabricated and introduced as lead test assemblies in commercial reactors, while others are still being developed. Several concepts were considered for pressurized-water reactors (PWRs) and boiling-water reactors (BWRs) in comparison to the current Zircaloy and UO2 fuel system. In most of these cases, the ATF materials did not significantly impact the number of applicable experiments for validation. Some fuel and cladding materials were identified, however, which may reduce the number of available experiments and which will increase the nuclear data–induced uncertainty in neutron multiplication.

Marshall, William (B.J.)↗

Monte Carlo investigation of I-125 interseed attenuation for standard and thinner seeds in prostate brachytherapy with phantom validation using a MOSFET

Purpose: In permanent seed implant prostate brachytherapy the actual dose delivered to the patient may be less than that calculated by TG-43U1 due to interseed attenuation (ISA) and differences between prostate tissue composition and water. In this study the magnitude of the ISA effect is assessed in a phantom and in clinical prostate postimplant cases. Results are compared for seed models 6711 and 9011 with 0.8 and 0.5 mm diameters, respectively. Methods: A polymethyl methacrylate (PMMA) phantom was designed to perform ISA measurements in a simple eight-seed arrangement and at the center of an implant of 36 seeds. Monte Carlo (MC) simulation and experimental measurements using a MOSFET dosimeter were used to measure dose rate and the ISA effect. MC simulations of 15 CT-based postimplant prostate treatment plans were performed to compare the clinical impact of ISA on dose to prostate, urethra, rectum, and the volume enclosed by the 100% isodose, for 6711 and 9011 seed models. Results: In the phantom, ISA reduced the dose rate at the MOSFET position by 8.6%-18.3% (6711) and 7.8%-16.7% (9011) depending on the measurement configuration. MOSFET measured dose rates agreed with MC simulation predictions within the MOSFET measurement uncertainty, which ranged from 5.5% to 7.2% depending on the measurement configuration (k= 1, for the mean of four measurements). For 15 clinical implants, the mean ISA effect for 6711 was to reduce prostate D90 by 4.2 Gy (3%), prostate V100 by 0.5 cc (1.4%), urethra D10 by 11.3 Gy (4.4%), rectal D2cc by 5.5 Gy (4.6%), and the 100% isodose volume by 2.3 cc. For the 9011 seed the mean ISA effect reduced prostate D90 by 2.2 Gy (1.6%), prostate V100 by 0.3 cc (0.7%), urethra D10 by 8.0 Gy (3.2%), rectal D2cc by 3.1 Gy (2.7%), and the 100% isodose volume by 1.2 cc. Differences between the MC simulation and TG-43U1 consensus data for the 6711 seed model had a similar impact, reducing mean prostate D90 by 6 Gy (4.2%) and V100 by 0.6 cc (1.8%). Conclusions: ISA causes the delivered dose in prostate seed implant brachytherapy to be lower than the dose calculated by TG-43U1. MC simulation of phantom seed arrangements show that dose at a point can be reduced by up to 18% and this has been validated using a MOSFET dosimeter. Clinical simulations show that ISA reduces DVH parameter values, but the reduction is less for thinner seeds.

60 APPLIED LIFE SCIENCES↗

The Effect of Kr-85 Decay to Rb-85 on Waste Forms - 17105

Krypton-85 (Kr-85) is a volatile radionuclide released during the reprocessing of used nuclear fuel (UNF). Prior to discharge of process off-gas streams to the environment, removal of Kr-85 is required to meet emission regulations. Once removed from the off-gas streams, Kr (containing stable Kr in addition to Kr-85) must be placed in storage until the Kr-85 has decayed to levels such that its potential release would meet regulatory guidelines. The current method of storage is high-pressure metal canisters. Historically, concerns have been expressed that the decay product of Kr-85, Rubidium-85 (Rb-85), could cause corrosion and weakening in the canisters that would ultimately lead to premature failure and release of Kr-85. Alternate methods and materials, such as matrix isolation in a vapor deposited metal and immobilization in zeolites, have been investigated as storage approaches for Kr. However, even these storage methods may become compromised due to the chemical effects of Rb-85 arising from the decay of Kr-85. A review was conducted of the available literature to examine topics relevant to the effects of Rb on the long-term storage of Kr-85, examine the source terms in the context of this concern, and suggest a path forward to resolve outstanding knowledge gaps. In the course of this analysis, several knowledge gaps were identified. Examples include: o The use of solid sorbents to potentially permit more Kr-85-bearing gas to be loaded into canisters, either at the pressures used in the current method or at significantly lower pressures. o A cost-to-benefit analysis is needed to ascertain the practicality of manufacturing waste forms for Kr-85 storage with solid sorbents. o The effects of radiation and chemical transmutation in solid sorbents or matrices for this application are virtually unknown. o Fundamental data are needed on corrosion rates and mechanisms as functions of Rb concentration, storage temperature, etc., for various storage approaches (e.g., as compressed gas or encapsulated in a getter material) and storage container materials. The present analysis focused on the available information regarding storage of Kr-85 in high-pressure containers. It was judged unlikely that such containers would be compromised by corrosion from the Rb decay product, especially if the Kr recovery operations result in a gas composition with very low oxygen content. However, this conclusion should be revisited based on preliminary data gathered from analysis of legacy Kr waste forms. These legacy waste forms are a result of experiments conducted at Idaho National Laboratory over 30 y ago and have been stored for more than three Kr-85 half-lives. Evaluation of these forms indicates significant corrosion, the cause of which has not been conclusively determined. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Neurohumoral indicators of efficacy radiofrequency cardiac denervation

In this study, we compared pre- and postoperative parameters of the cardiac sympathetic innervation. The aim of the study was to examine the approaches to evaluating the quality of radiofrequency (RF)-induced cardiac denervation by using non-invasive and laboratory methods. The study included 32 people with long-lasting persistent atrial fibrillation (AF). The patients were divided into 2 groups according to the objectives of the study: group 1 (main) - 21 patients with mitral valve diseases, which simultaneously with radiofrequency ablation (RFA) AF carried out on the effects of the paraganglionic nervous plexuses by C. Pappone (2004) and N. Doll (2008) schemes. The second group (control) contained 11 patients with heart diseases in sinus rhythm (the RF denervation not been performed). All patients, who underwent surgical treatment, were received examination of cardiac sympathetic tone by using {sup 123}I-MIBG. All of them made blood analysis from ascending aorta and coronary sinus to determine the level of norepinephrine and its metabolites before and after cardiac denervation. Data of radionuclide examination are correlating with laboratory data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Are We Appropriately Selecting Therapy For Patients With Cervical Cancer? Longitudinal Patterns-of-Care Analysis for Stage IB-IIB Cervical Cancer

Purpose: We performed a patterns-of-care analysis evaluating the effects of newer technology and recent research findings on treatment decisions over 26 years to determine whether patients with cervical cancer are being appropriately selected for treatment to optimize the therapeutic ratio. Methods and Materials: A retrospective analysis was conducted using the Surveillance, Epidemiology and End Results (SEER) program from 1983 to 2009. We identified 10,933 women with stage IB-IIB cervical carcinoma. Results: Of the 10,933 subjects identified, 40.1% received surgery, 26.8% received radiation (RT), and 33.1% received surgery plus RT. RT use increased after 2000 compared to prior to 2000, with a corresponding decrease in surgery and surgery plus RT. Among patients with risk factors including tumor size >4 cm, positive parametria, and positive lymph nodes, declining use of surgery plus RT was observed. However, 23% of patients with tumors >4 cm, 20% of patients with positive parametria, and 55% of node-positive patients continued to receive surgery plus RT as of 2009. Factors associated with increased use of surgery plus RT included patient age <50 and node-positive status. Conclusions: In this largest patterns-of-care analysis to date for patients with locally advanced cervical cancer, we found a substantial proportion of patients continue to undergo surgery followed by radiation, despite randomized data supporting the use of definitive radiation therapy, with lower morbidity than surgery and radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Doses to Carotid Arteries After Modern Radiation Therapy for Hodgkin Lymphoma: Is Stroke Still a Late Effect of Treatment?

Purpose: Hodgkin lymphoma (HL) survivors are at an increased risk of stroke because of carotid artery irradiation. However, for early-stage HL involved node radiation therapy (INRT) reduces the volume of normal tissue exposed to high doses. Here, we evaluate 3-dimensional conformal radiation therapy (3D-CRT), volumetric-modulated arc therapy (VMAT), and proton therapy (PT) delivered as INRT along with the extensive mantle field (MF) by comparing doses to the carotid arteries and corresponding risk estimates. Methods and Materials: We included a cohort of 46 supradiaphragmatic stage I-II classical HL patients. All patients were initially treated with chemotherapy and INRT delivered as 3D-CRT (30 Gy). For each patient, we simulated MF (36 Gy) and INRT plans using VMAT and PT (30 Gy). Linear dose-response curves for the 20-, 25-, and 30-year risk of stroke were derived from published HL data. Risks of stroke with each technique were calculated for all patients. Statistical analyses were performed with repeated measures analysis of variance. Results: The mean doses to the right and left common carotid artery were significantly lower with modern treatment compared with MF, with substantial patient variability. The estimated excess risk of stroke after 20, 25, and 30 years was 0.6%, 0.86%, and 1.3% for 3D-CRT; 0.67%, 0.96%, and 1.47% for VMAT; 0.61%, 0.96%, and 1.33% for PT; and 1.3%, 1.72%, and 2.61% for MF. Conclusions: INRT reduces the dose delivered to the carotid arteries and corresponding estimated risk of stroke for HL survivors. Even for the subset of patients with lymphoma close to the carotid arteries, the estimated risk is low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗