Estimation of Total Skeletal Content of Plutonium and 241Am From Analysis of a Single Bone
Not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Not provided.
Not provided.
Not provided.
Not provided.
Not provided.
Abstract Historical assessment of radiation effects at low doses (below 0.2 Sv) are generally the result of back extrapolation from higher doses, which are known to have a linear relation between risk and dose. There are multiple counter-examples, and some literature argues that a threshold, nonlinear, or even a beneficial effect (hormeisis) can occur from radiation below these doses. The common theme found in all of these studies stems from the traditional approach of correlating disease rates to stimulus and then effectively curve-fitting the result toward zero dose. What has not been considered in general are the personal stress levels of the exposed individuals due to fear of cancer from low doses. The increased levels of cortisol due to the psychological stress from fear or depression has been shown in the literature to increase cancer probability. The extent to which low-dose exposed individuals were highly fearful or stressed from the radiation exposure would then give rise to elevated cancer based on stress rather than a fundamental radiogenic mechanism. If the population under epidemiological study is aware of a potential historical exposure (no matter how small) and has then lived under stress from fear or depression due to that exposure, the psychosomatic effects will bias the epidemiology accordingly and so should be quantified and accounted for as done with the effects of smoking. Health Phys. 129(0):000-000; 2025
Abstract Accurate dosimetry is a crucial component of small animal and preclinical irradiation studies. Various dosimetry options are available but fail to characterize complex geometries and variable energy spectra of modern x-ray irradiators accurately. These options also lack national/international standards of recognition. This paper presents a novel dosimetry system, Dosequate, which uses murine phantoms embedded with alanine dosimeters and paired with x-ray energy spectra corrections to deliver consistent and accurate dosimetry measurements. This study compares Dosequate measurements against a Precision X-RAD 320 internal ion chamber and the treatment planning system of an Xstrahl Small Animal Radiation Research Platform. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. Results demonstrate the accuracy and reproducibility of the Dosequate system, highlighting its potential for standardizing dosimetry in preclinical research throughout the industry. The Dosequate dosimetry method provides a robust and standardized approach for measuring absorbed dose in small animal irradiators. Its accuracy, reproducibility, and ability to account for complex irradiation geometries make it a valuable tool for preclinical research. This system has the potential to significantly improve the intercomparability of studies across different facilities and enhance the reliability of results.
Abstract not provided.
Natural aging is associated with mild memory loss and cognitive decline, and age is the greatest risk factor for neurodegenerative diseases, such as Alzheimer’s disease. There is substantial evidence that oxidative stress is a major contributor to both natural aging and neurodegenerative disease, and coincidently, levels of redox active metals such as Fe and Cu are known to be elevated later in life. Recently, a pronounced age-related increase in Cu content has been reported to occur in mice and rats around a vital regulatory brain region, the subventricular zone of lateral ventricles. In our study herein, we have characterized lateral ventricle Cu content in a unique murine model of accelerated aging, senescence accelerated mouse-prone 8 (SAMP8) mice. Our results confirm an age-related increase in ventricle Cu content, consistent with the studies by others in wild-type mice and rats. Specifically, we observed Cu content to increase over the time frame 1 to 5 months and 5 to 9 months, but interestingly, no significant increase occurred between 9 and 12 months (although brain Cu content at 12 months was significantly elevated relative to 1 and 5 month-old animals). Despite the magnitude of Cu increase observed within the cells that comprise the subventricular zone of lateral ventricles (average 3 mM Cu, with isolated subcellular concentrations of 17 mM), we did not detect spectroscopic markers of thiol oxidation, protein aggregation, or lipid oxidation. The lack of evidence for oxidative stress in ex vivo animal tissue is in contrast to in vitro studies demonstrating that thiol, protein, and lipid oxidation is pronounced at these Cu concentrations. We suggest that our findings most likely indicate that the Cu ions in this brain region are sequestered in an unreactive form, possibly extended chains of Cu-thiolate complexes, which do not readily redox cycle in the aqueous cytosol. In conclusion, these results also appear to partially challenge the long-held view that age-related increases in brain metal content drive oxidative stress as we did not observe a concomitant association between age-related Cu increase and markers of oxidative stress, nor did we observe a net increase in Cu content between mice aged 9 and 12 months.
Polarized ion beams at the Electron Ion Collider (EIC) are essential to address some of the most important open questions at the twenty-first century frontiers of understanding of the fundamental structure of matter. Here, in this work, we summarize the science case and identify polarized 2 H, 3 He, 6 Li, and 7 Li ion beams as critical technology that will enable experiments which address the most important science. Furthermore, we discuss the required ion polarimetry and spin manipulation at the EIC. The current EIC accelerator design is presented. We identify a significant research and development effort across national and international laboratories and universities that is required over about a decade to realize the polarized ion beams and estimate (based on previous experience) that it will require about 20 full-time equivalent (FTE) over 10 years (or a total of about 200 FTE-years) of personnel, including graduate students, postdoctoral researchers, technicians, and engineers. Attracting, educating, and training a new generation of physicists in experimental spin techniques will be essential for the successful realization. Artificial intelligence and machine learning are seen as having significant potential for both acceleration of research and development and amplification of discovery in the optimal realization of this unique quantum technology on a cutting-edge collider. The research and development effort is synergistic with research in atomic physics and fusion energy science.
Graphite overview: Material science, supply chain facts, nuclear material science, licensing thoughts
This is the final report of the project titled, 'Isotope Identification Algorithm for Rapid and Accurate Determination of Radioisotopes,' PMIS project number LA10-HUMANID-PD03. The goal of the work was to demonstrate principles of emulating a human analysis approach towards the data collected using radiation isotope identification devices (RIIDs). It summarizes work performed over the FY10 time period. The goal of the work was to demonstrate principles of emulating a human analysis approach towards the data collected using radiation isotope identification devices (RIIDs). Human analysts begin analyzing a spectrum based on features in the spectrum - lines and shapes that are present in a given spectrum. The proposed work was to carry out a feasibility study that will pick out all gamma ray peaks and other features such as Compton edges, bremsstrahlung, presence/absence of shielding and presence of neutrons and escape peaks. Ultimately success of this feasibility study will allow us to collectively explain identified features and form a realistic scenario that produced a given spectrum in the future. We wanted to develop and demonstrate machine learning algorithms that will qualitatively enhance the automated identification capabilities of portable radiological sensors that are currently being used in the field.
Abstract Not Provided.
Founded in 1996 upon the initiative of the “Group of 8” governments (G8), the Nuclear Forensics International Technical Working Group (ITWG) is an ad hoc organization of official Nuclear Forensics practitioners (scientists, law enforcement, and regulators) that can be called upon to provide technical assistance to the global community in the event of a seizure of nuclear or radiological materials. The ITWG is supported by and is affiliated with nearly 40 countries and international partner organizations including the International Atomic Energy Agency (IAEA), EURATOM, INTERPOL, EUROPOL, and the United Nations Interregional Crime and Justice Research Institute (UNICRI) (Figure 1). Besides providing a network of nuclear forensics laboratories that are able to assist the global community during a nuclear smuggling event, the ITWG is also committed to the advancement of the science of nuclear forensic analysis, largely through participation in periodic table top and Collaborative Materials Exercises (CMXs). Exercise scenarios use “real world” samples with realistic forensics investigation time constraints and reporting requirements. These exercises are designed to promote best practices in the field and test, evaluate, and improve new technical capabilities, methods and techniques in order to advance the science of nuclear forensics. Past efforts to advance nuclear forensic science have also included scenarios that asked laboratories to adapt conventional forensics methods (e.g. DNA, fingerprints, tool marks, and document comparisons) for collecting and preserving evidence comingled with radioactive materials.
Abstract In biokinetic modeling systems employed for radiation protection, biological retention and excretion have been modeled as a series of discretized compartments representing the organs and tissues of the human body. Fractional retention and excretion in these organ and tissue systems have been mathematically governed by a series of coupled first-order ordinary differential equations (ODEs). The coupled ODE systems comprising the biokinetic models are usually stiff due to the severe difference between rapid and slow transfers between compartments. In this study, the capabilities of solving a complex coupled system of ODEs for biokinetic modeling were evaluated by comparing different Python programming language solvers and solving methods with the motivation of establishing a framework that enables multi-level analysis. The stability of the solvers was analyzed to select the best performers for solving the biokinetic problems. A Python-based linear algebraic method was also explored to examine how the numerical methods deviated from an analytical or semi-analytical method. Results demonstrated that customized implicit methods resulted in an enhanced stable solution for the inhaled 60 Co (Type M) and 131 I (Type F) exposure scenarios for the inhalation pathway of the International Commission on Radiological Protection (ICRP) Publication 130 Human Respiratory Tract Model (HRTM). The customized implementation of the Python-based implicit solvers resulted in approximately consistent solutions with the Python-based matrix exponential method ( expm ). The differences generally observed between the implicit solvers and expm are attributable to numerical precision and the order of numerical approximation of the numerical solvers. This study provides the first analysis of a list of Python ODE solvers and methods by comparing their usage for solving biokinetic models using the ICRP Publication 130 HRTM and provides a framework for the selection of the most appropriate ODE solvers and methods in Python language to implement for modeling the distribution of internal radioactivity.
A multi-modal approach combining in situ X-ray absorption spectroscopy, optical spectroscopy, and ab initio molecular dynamics simulations was used to investigate and understand nickel metal speciation in molten salt systems.
Neutron Resonance Transmission Analysis (NRTA) is a spectroscopic technique which uses the resonant absorption of neutrons in the epithermal range to infer the isotopic composition of an object. This spectroscopic technique has relevance in many traditional fields of science and nuclear security. NRTA in the past made use of large, expensive accelerator facilities to achieve precise neutron beams, significantly limiting its applicability. Here, we describe a series of NRTA experiments where we use a compact, low-cost deuterium-tritium (DT) neutron generator to produce short neutron beams (2.6 m) along with a 6 Li-glass neutron detector. The time-of-flight spectral data from five elements – silver, cadmium, tungsten, indium, and 238 U – clearly show the corresponding absorption lines in the 1-30 eV range. The experiments show the applicability of NRTA in this simplified configuration, and prove the feasibility of this compact and low-cost approach. This could significantly broaden the applicability of NRTA, and make it practical and applicable in many fields, such as material science, nuclear engineering, and arms control.