Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

A Microwave Radiometric Method to Obtain the Average Path Profile of Atmospheric Temperature and Humidity Structure Parameters and Its Application to Optical Propagation System Assessment

The values of the key atmospheric propagation parameters Ct2, Cq2, and Ctq are highly dependent upon the vertical height within the atmosphere thus making it necessary to specify profiles of these values along the atmospheric propagation path. The remote sensing method suggested and described in this work makes use of a rapidly integrating microwave profiling radiometer to capture profiles of temperature and humidity through the atmosphere. The integration times of currently available profiling radiometers are such that they are approaching the temporal intervals over which one can possibly make meaningful assessments of these key atmospheric parameters. Since these parameters are fundamental to all propagation conditions, they can be used to obtain Cn2 profiles for any frequency, including those for an optical propagation path. In this case the important performance parameters of the prevailing isoplanatic angle and Greenwood frequency can be obtained. The integration times are such that Kolmogorov turbulence theory and the Taylor frozen-flow hypothesis must be transcended. Appropriate modifications to these classical approaches are derived from first principles and an expression for the structure functions are obtained. The theory is then applied to an experimental scenario and shows very good results.

Atmospheric turbulence↗

Comparison of Angle of Attack Measurements for Wind Tunnel Testing

Two optical systems capable of measuring model attitude and deformation were compared to inertial devices employed to acquire wind tunnel model angle of attack measurements during the sting mounted full span 30% geometric scale flexible configuration of the Northrop Grumman Unmanned Combat Air Vehicle (UCAV) installed in the NASA Langley Transonic Dynamics Tunnel (TDT). The overall purpose of the test at TDT was to evaluate smart materials and structures adaptive wing technology. The optical techniques that were compared to inertial devices employed to measure angle of attack for this test were: (1) an Optotrak (registered) system, an optical system consisting of two sensors, each containing a pair of orthogonally oriented linear arrays to compute spatial positions of a set of active markers; and (2) Video Model Deformation (VMD) system, providing a single view of passive targets using a constrained photogrammetric solution whose primary function was to measure wing and control surface deformations. The Optotrak system was installed for this test for the first time at TDT in order to assess the usefulness of the system for future static and dynamic deformation measurements.

Jones, Thomas, W.↗

On Hilbert-Huang Transform Based Synthesis of a Signal Contaminated by Radio Frequency Interference or Fringes

Norden E. Huang et al. had proposed and published the Hilbert-Huang Transform (HHT) concept correspondently in 1996, 1998. The HHT is a novel method for adaptive spectral analysis of non-linear and non-stationary signals. The HHT comprises two components: - the Huang Empirical Mode Decomposition (EMD), resulting in an adaptive data-derived basis of Intrinsic Mode functions (IMFs), and the Hilbert Spectral Analysis (HSA1) based on the Hilbert Transform for 1-dimension (1D) applied to the EMD IMF's outcome. Although paper describes the HHT concept in great depth, it does not contain all needed methodology to implement the HHT computer code. In 2004, Semion Kizhner and Karin Blank implemented the reference digital HHT real-time data processing system for 1D (HHT-DPS Version 1.4). The case for 2-Dimension (2D) (HHT2) proved to be difficult due to the computational complexity of EMD for 2D (EMD2) and absence of a suitable Hilbert Transform for 2D spectral analysis (HSA2). The real-time EMD2 and HSA2 comprise the real-time HHT2. Kizhner completed the real-time EMD2 and the HSA2 reference digital implementations respectively in 2013 & 2014. Still, the HHT2 outcome synthesis remains an active research area. This paper presents the initial concepts and preliminary results of HHT2-based synthesis and its application to processing of signals contaminated by Radio-Frequency Interference (RFI), as well as optical systems' fringe detection and mitigation at design stage. The Soil Moisture Active Passive (SMAP mission (SMAP) carries a radiometer instrument that measures Earth soil moisture at L1 frequency (1.4 GHz polarimetric - H, V, 3rd and 4th Stokes parameters). There is abundant RFI at L1 and because soil moisture is a strategic parameter, it is important to be able to recover the RFI-contaminated measurement samples (15% of telemetry). State-of-the-art only allows RFI detection and removes RFI-contaminated measurements. The HHT-based analysis and synthesis facilitates recovery of measurements contaminated by all kinds of RFI, including jamming [7-8]. The fringes are inherent in optical systems and multi-layer complex contour expensive coatings are employed to remove the unwanted fringes. HHT2-based analysis allows test image decomposition to analyze and detect fringes, and HHT2-based synthesis of useful image.

Spacecraft Electronics Equipment↗

POLARIMETRY WITH THE GEMINI PLANET IMAGER: METHODS, PERFORMANCE AT FIRST LIGHT, AND THE CIRCUMSTELLAR RING AROUND HR 4796A

We present the first results from the polarimetry mode of the Gemini Planet Imager (GPI), which uses a new integral field polarimetry architecture to provide high contrast linear polarimetry with minimal systematic biases between the orthogonal polarizations. We describe the design, data reduction methods, and performance of polarimetry with GPI. Point-spread function (PSF) subtraction via differential polarimetry suppresses unpolarized starlight by a factor of over 100, and provides sensitivity to circumstellar dust reaching the photon noise limit for these observations. In the case of the circumstellar disk around HR 4796A, GPI's advanced adaptive optics system reveals the disk clearly even prior to PSF subtraction. In polarized light, the disk is seen all the way in to its semi-minor axis for the first time. The disk exhibits surprisingly strong asymmetry in polarized intensity, with the west side ≳ 9 times brighter than the east side despite the fact that the east side is slightly brighter in total intensity. Based on a synthesis of the total and polarized intensities, we now believe that the west side is closer to us, contrary to most prior interpretations. Forward scattering by relatively large silicate dust particles leads to the strong polarized intensity on the west side, and the ring must be slightly optically thick in order to explain the lower brightness in total intensity there. These findings suggest that the ring is geometrically narrow and dynamically cold, perhaps shepherded by larger bodies in the same manner as Saturn's F ring.

79 ASTRONOMY AND ASTROPHYSICS↗

Confocal volume in laser Raman microscopy depth profiling

To clarify the degradation of confocality in laser Raman microscopy depth profiling (optical sectioning) and the influence of pinhole filtering on it, we investigate the confocal volume in detail based on Gaussian beam optics and scalar wave optics. Theoretical depth profiles of a homogeneous transparent sample for four different pinhole sizes, which are computed using the measured incident beam waist radius w{sub 0} and only a few optical system specific parameters such as a numerical aperture (NA) and a focal length, show a good agreement with the corresponding measured depth profiles. The computed confocal volume demonstrates that the pinhole size affects the actual probe depth as well as the axial resolution and the total intensity loss.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Space infrared telescope facility wide field and diffraction limited array camera (IRAC)

The wide-field and diffraction limited array camera (IRAC) is capable of two-dimensional photometry in either a wide-field or diffraction-limited mode over the wavelength range from 2 to 30 microns with a possible extension to 120 microns. A low-doped indium antimonide detector was developed for 1.8 to 5.0 microns, detectors were tested and optimized for the entire 1.8 to 30 micron range, beamsplitters were developed and tested for the 1.8 to 30 micron range, and tradeoff studies of the camera's optical system performed. Data are presented on the performance of InSb, Si:In, Si:Ga, and Si:Sb array detectors bumpbonded to a multiplexed CMOS readout chip of the source-follower type at SIRTF operating backgrounds (equal to or less than 1 x 10 to the 8th ph/sq cm/sec) and temperature (4 to 12 K). Some results at higher temperatures are also presented for comparison to SIRTF temperature results. Data are also presented on the performance of IRAC beamsplitters at room temperature at both 0 and 45 deg angle of incidence and on the performance of the all-reflecting optical system baselined for the camera.

Fazio, Giovanni G.↗

Detection limits for actinides in a monochromatic, wavelength-dispersive x-ray fluorescence instrument

Recent developments in x-ray optics have made it possible to examine the L x-rays of actinides using doubly-curved crystals in a bench-top device. A doubly-curved crystal (DCC) acts as a focusing monochromatic filter for polychromatic x-rays. A Monochromatic, Wavelength-Dispersive X-Ray Fluorescence (MWDXRF) instrument that uses DCCs to measure Cm and Pu in reprocessing plant liquors was proposed in 2007 by the authors at Los Alamos National Laboratory. A prototype design of this MWDXRF instrument was developed in collaboration with X-ray Optical Systems Inc. (XOS), of East Greenbush, New York. In the MWDXRF instrument, x-rays from a Rhodium-anode x-ray tube are passed through a primary DCC to produce a monochromatic beam of 20.2-keV photons. This beam is focused on a specimen that may contain actinides. The 20.2-keV interrogating beam is just above the L3 edge of Californium; each actinide (with Z = 90 to 98) present in the specimen emits characteristic L x-rays as the result of L3-shell vacancies. In the LANL-XOS prototype MWDXRf, these x-rays enter a secondary DCC optic that preferentially passes 14.961-keV photons, corresponding to the L-alpha-1 x-ray peak of Curium. In the present stage of experimentation, Curium-bearing specimens have not been analyzed with the prototype MWDXRF instrument. Surrogate materials for Curium include Rubidium, which has a K-beta-l x-ray at 14.961 keV, and Yttrium, which has a K-alpha-1 x-ray at 14.958 keV. In this paper, the lower limit of detection for Curium in the LANL-XOS prototype MWDXRF instrument is estimated. The basis for this estimate is described, including a description of computational models and benchmarking techniques used. Detection limits for other actinides are considered, as well as future safeguards applications for MWDXRF instrumentation.

36 MATERIALS SCIENCE↗

Evaluation of accuracy and resolution of the electron beam profile scanner at the Fermilab Main Injector

The objective of this work is to assess the accuracy of measurements made by the Electron Beam Profile Scanner (EBPS), which captures the trajectory of an electron beam with and without a proton beam present. The proton beam induces deflection in the electron beam, which is influenced by proton charges.For high-resolution images, the probe beam needs to be of high intensity, small diameter, and small divergence, evaluated using a YAG screen and an optical transition radiation (OTR) screen. Additionally, the point spread function (PSF) will be calculated to characterize the optical system's properties using ZEMAX software. The capabilities of the Hamamatsu Charge-Injection Device (CID) camera and Kimball Physics electron gun (e-gun) will be considered for accuracy.

Mwaniki, Matilda [IIT, Chicago; Fermilab]↗

Floquet Chern insulators of light

Achieving topologically-protected robust transport in optical systems has recently been of great interest. Most studied topological photonic structures can be understood by solving the eigenvalue problem of Maxwell’s equations for static linear systems. Here, we extend topological phases into dynamically driven systems and achieve a Floquet Chern insulator of light in nonlinear photonic crystals (PhCs). Specifically, we start by presenting the Floquet eigenvalue problem in driven two-dimensional PhCs. We then define topological invariant associated with Floquet bands, and show that topological band gaps with non-zero Chern number can be opened by breaking time-reversal symmetry through the driving field. Finally, we numerically demonstrate the existence of chiral edge states at the interfaces between a Floquet Chern insulator and normal insulators, where the transport is non-reciprocal and uni-directional. Our work paves the way to further exploring topological phases in driven optical systems and their optoelectronic applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cooperative emission from an ensemble of three-level Λ radiators in a cavity: An insight from the viewpoint of dynamics of nonlinear systems

Cooperative radiation emitted by an ensemble of three-level optical systems with a doublet in the ground state (Λ scheme), which is placed into a cyclic cavity, is studied theoretically. In contrast to the two-level model of emitters, this process with such a configuration of operating transitions may occur without population inversion in the whole, if the doublet is prepared at the initial instant in a superposition (coherent) state. In the ideal case of a Hamilton system, in which the cavity losses and relaxation in the radiator ensemble are disregarded, the conservation laws are derived, which allow a substantial reduction of the dimension of the phase space of the model (ℝ{sup 11} → ℝ{sup 5}) and the application of methods of dynamics of nonlinear systems for analyzing the three-level superradiance under these conditions. The possibility of different (both quasiperiodic and chaotic) scenarios of the three-level superradiance is demonstrated on the basis of Poincaré’s mappings. Global bifurcation of the system upon a transition from the conventional superradiance regime to inversionless one is revealed. The effects of cavity losses, as well as homogeneous and inhomogeneous broadening in the system of radiators on the regularities found are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lyman-Alpha Imaging Polarimetry with the CLASP2 Sounding Rocket Mission

Ultraviolet polarimetry offers a unique opportunity to explore the upper solar chromosphere and the transition region (TR) to the million-degree corona. These outer atmospheric regions play a key role in the transfer of mass and energy from the solar photosphere to the corona. With a sounding rocket experiment called the Chromospheric Lyman-Alpha Spectro-Polarimeter (CLASP), in September 2015 we succeeded in obtaining the first measurement of the linear polarization produced by scattering processes in the hydrogen Lyman-alpha line of the solar disk radiation. The analysis and interpretation of such spectro-polarimetric observation allowed us to obtain information on the geometrical complexity of the corrugated surface that delineates the TR, as well as on the magnetic field strength via the Hanle effect. At the same time, the CLASP slit-jaw (SJ) optics system, which is a Lyman-alpha filter imager characterized by a FWHM (Full Width Half Maximum) equals 7 nanometers, allowed us to obtain broad-band Stokes-I and Q/I images over a large field of view. The obtained broad-band Q/I images are dominated by the scattering polarization signals of the Lyman-alpha wings, and not by the much weaker line-center signals where the Hanle effect operates. On April 11, 2019, we performed another sounding rocket experiment, called the Chromospheric LAyer Spectro-Polarimeter (CLASP2). We used the same instrument after significant modifications in order to obtain spectro-polarimetric observations of a plage and a quiet region in the Mg II h & k lines. At the same time, the CLASP2 SJ optics system allowed us to obtain broad-band Q/I and U/I images around the Lyman-alpha wavelength, in addition to the well- known SJ intensity images.

Kano, Ryouhei↗

NGST Optical Testing

An Integrated Product Team (IPT) was formed to develop a detailed optical test methodology for testing of the Next Generation Space Telescope (NGST) mirrors and the optical system on the ground. Optical testing is a significant cost driver therefore the testing has to be planned in detailed fashion early. This paper will discuss the preliminary metrology test plan at the mirror component and telescope system level. Instrumentation, facilities and schedule will also be addressed.

Keski-Kuha, Ritva↗

Wavefront Control and Image Restoration with Less Computing

PseudoDiversity is a method of recovering the wavefront in a sparse- or segmented- aperture optical system typified by an interferometer or a telescope equipped with an adaptive primary mirror consisting of controllably slightly moveable segments. (PseudoDiversity should not be confused with a radio-antenna-arraying method called pseudodiversity.) As in the cases of other wavefront- recovery methods, the streams of wavefront data generated by means of PseudoDiversity are used as feedback signals for controlling electromechanical actuators of the various segments so as to correct wavefront errors and thereby, for example, obtain a clearer, steadier image of a distant object in the presence of atmospheric turbulence. There are numerous potential applications in astronomy, remote sensing from aircraft and spacecraft, targeting missiles, sighting military targets, and medical imaging (including microscopy) through such intervening media as cells or water. In comparison with prior wavefront-recovery methods used in adaptive optics, PseudoDiversity involves considerably simpler equipment and procedures and less computation. For PseudoDiversity, there is no need to install separate metrological equipment or to use any optomechanical components beyond those that are already parts of the optical system to which the method is applied. In Pseudo- Diversity, the actuators of a subset of the segments or subapertures are driven to make the segments dither in the piston, tilt, and tip degrees of freedom. Each aperture is dithered at a unique frequency at an amplitude of a half wavelength of light. During the dithering, images on the focal plane are detected and digitized at a rate of at least four samples per dither period. In the processing of the image samples, the use of different dither frequencies makes it possible to determine the separate effects of the various dithered segments or apertures. The digitized image-detector outputs are processed in the spatial-frequency (Fourier-transform) domain to obtain measures of the piston, tip, and tilt errors over each segment or subaperture. Once these measures are known, they are fed back to the actuators to correct the errors. In addition, measures of errors that remain after correction by use of the actuators are further utilized in an algorithm in which the image is phase-corrected in the spatial-frequency domain and then transformed back to the spatial domain at each time step and summed with the images from all previous time steps to obtain a final image having a greater signal-to-noise ratio (and, hence, a visual quality) higher than would otherwise be attainable.

Lyon, Richard G.↗

Design of an achromatic and uncoupled medical gantry for radiation therapy

We are presenting the layout and the optics of a beam line to be used as a medical gantry in radiation therapy. The optical properties of the gantry's beam line are such as to make the beam line achromatic and uncoupled. These two properties make the beam spot size, which is delivered and focused by the gantry, on the tumor of the patient, independent of the angular orientation of the gantry. In this paper we present the layout of the magnetic elements of the gantry, and also present the theoretical basis for the optics design of such a gantry. A medical gantry, as it is used in the radiation treatment of cancer patients, is the last part of the beam optical system, of the accelerator complex, which delivers and focuses the beam on the tumor. The curved line shown in figure 1 is a schematic diagram of a gantry which can rotate about a horizontal axis. The particle beam (green arrow in fig. 1) enters the gantry, and is guided by the gantry on the tumor (red spot in fig. 1). As the gantry rotates about the axis shown in figure 1, the beam exiting the gantry always lies on a plane normal to the rotation axis at the point of the icocenter. Thus the gantry facilitates the ability of the beam delivery system, to deliver the beam at the tumor, which is placed at the icocenter, from any angle on this vertical plane, which is normal to the rotation angle of the gantry as stated earlier. The gantry consists of dipoles and quadrupoles elements whose median symmetry plane lies on a plane which contains the rotation axis of the gantry. In this paper we define this plane as the 'plane of the gantry'. As the beam is transported along the axis of rotation of the gantry and before it enters the gantry, it is focused by 'normal' quadrupoles and experiences no linear beam coupling. Subsequently the beam enters the gantry, and is transported by the gantry to the delivery point which is the tumor. The transported beam at the tumor is still linearly uncoupled as long as the plane of the gantry lies either, on the horizontal, or the vertical plane. In these two orientations of the gantry the dipoles and the quadrupoles are 'normal' therefore the linear R-transport-matrix appears linearly uncoupled. As the gantry rotates about this horizontal axis, to irradiate the tumor at a different angle, the linear beam coupling is unavoidable since the coordinate system of the gantry's quadrupoles is rotated with respect to the coordinate system of the quadrupoles at the entrance of the gantry which are located along the axis of rotation. As a result, in this rotated coordinate system, the beam will be linearly coupled as it is transported by the gantry to the tumor and the beam size at the location of the tumor will vary in size depending on the orientation of the gantry. In this paper we present a method which makes the beam transport R-matrix linearly uncoupled, achromatic and independent of the orientation angle of the gantry as is proven in the following section.

43 PARTICLE ACCELERATORS↗

To what extent can space be compressed? Bandwidth limits of spaceplates

Spaceplates are novel flat-optic devices that implement the optical response of a free-space volume over a smaller length, effectively “compressing space” for light propagation. Together with flat lenses such as metalenses or diffractive lenses, spaceplates have the potential to enable the miniaturization of any free-space optical system. While the fundamental and practical bounds on the performance metrics of flat lenses have been well studied in recent years, a similar understanding of the ultimate limits of spaceplates is lacking, especially regarding the issue of bandwidth, which remains as a crucial roadblock for the adoption of this platform. In this work, we derive fundamental bounds on the bandwidth of spaceplates as a function of their numerical aperture and compression ratio (ratio by which the free-space pathway is compressed). The general form of these bounds is universal and can be applied and specialized for different broad classes of space-compression devices, regardless of their particular implementation. Our findings also offer relevant insights into the physical mechanism at the origin of generic space-compression effects and may guide the design of higher performance spaceplates, opening new opportunities for ultra-compact, monolithic, planar optical systems for a variety of applications.

Shastri, Kunal (ORCID:0000000169282753)↗

Performance of the Gemini Planet Imager Non-redundant Mask and Spectroscopy of Two Close-separation Binaries: HR 2690 and HD 142527

The Gemini Planet Imager (GPI) contains a 10-hole non-redundant mask (NRM), enabling interferometric resolution in complement to its coronagraphic capabilities. The NRM operates both in spectroscopic (integral field spectrograph, henceforth IFS) and polarimetric configurations. NRM observations were taken between 2013 and 2016 to characterize its performance. Most observations were taken in spectroscopic mode, with the goal of obtaining precise astrometry and spectroscopy of faint companions to bright stars. We find a clear correlation between residual wavefront error measured by the adaptive optic system and the contrast sensitivity by comparing phase errors in observations of the same source, taken on different dates. We find a typical 5σ contrast sensitivity of (2–3) × 10 –3 at $~λ/D$. We explore the accuracy of spectral extraction of secondary components of binary systems by recovering the signal from a simulated source injected into several data sets. We outline data reduction procedures unique to GPI's IFS and describe a newly public data pipeline used for the presented analyses. We demonstrate recovery of astrometry and spectroscopy of two known companions to HR 2690 and HD 142527. NRM+polarimetry observations achieve differential visibility precision of σ ~ 0.4% in the best case. We discuss its limitations on Gemini-S/GPI for resolving inner regions of protoplanetary disks and prospects for future upgrades. We summarize lessons learned in observing with NRM in spectroscopic and polarimetric modes.

79 ASTRONOMY AND ASTROPHYSICS↗

In-situ tube burst testing and high-temperature deformation behavior of candidate materials for accident tolerant fuel cladding

The high resistance of cladding to plastic deformation and burst failure is one of the most essential properties of accident tolerant fuel (ATF) for maintaining structural integrity during a loss-of-coolant accident (LOCA) since the deformation and burst behavior governs the cooling efficiency of flow channels and process of fission product release. To simulate and evaluate such deformation and burst process of thin-walled cladding, an in-situ testing and evaluation method has been developed on the basis of visual imaging and image analysis techniques. The method uses a specialized optics system consisted of a high-resolution video camera, light filtering unit, and monochromatic light sources, and the in-situ testing is performed using a 50 mm long pressurized thin-walled tubular specimen set in a programmable furnace. In this study eleven (11) candidate cladding materials for ATF, i.e., 6 FeCrAl alloys and 5 nanostructured steels, were tested using the newly developed method, and the time-dependent images were analyzed to produce detailed deformation and burst data such as true hoop stress, strain (creep) rate, and failure stress. Relatively soft FeCrAl alloys deformed and burst below 800°C while negligible strain rates were measured for higher strength alloys and/or for relatively thick wall specimens.

Gussev, Maxim N.↗

Third-order dispersion drastically changes parametric gain in optical fiber systems

We demonstrate that the third-order dispersion drastically changes the phase-sensitive parametric gain in cw-pumped fiber systems. We analytically calculate the phase-sensitive gain as a function of the frequency for amplification of two weak monochromatic fields with spectral components symmetric with respect to the pump field. In the absence of the third-order dispersion, the phase-sensitive gain is symmetric with respect to the frequency. When the third-order dispersion is present, the gain has an asymmetric shape. This asymmetry has its origin in the phase-sensitive nature of the parametric gain.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗