At least 1,063 records · Page 59

Anode power deposition in a MPD thruster with a magnetically annulled Hall parameter anode

Results from previous studies indicate that the anode fall increases monotonically with the electron Hall parameter. In an attempt to reduce the anode fall by decreasing the local electron Hall parameter, a proof-of-concept test was performed in which an array of 36 permanent magnets were imbedded within the anode of a high power quasi-steady MPD thruster to decrease the local azimuthal component of the induced magnetic field. The modified thruster was operated at power levels between 150 kW and 4 MW with Ar and He propellants. Terminal voltage, triple probe, floating probe, and magnetic probe measurements were made to characterize the performance of the thruster with new anode. Incorporation of the modified anode resulted in a reduction of the anode fall by up to 15 V with Ar and 20 V with He, which corresponded to decreased anode power fractions of 40 and 45 percent with Ar and He, respectively.

Gallimore, Alec D.↗

Preliminary Results of the Magnetic Properties Experiments on the Mars Exploration Rovers, Spirit and Opportunity

The Mars Exploration Rovers each carry a set of Magnetic Properties Experiments designed to investigate the properties of the air-borne dust in the Martian atmosphere. It is a preferred interpretation of previous experiments (Viking 1 & 2, 1976 and Mars Pathfinder, 1997) that the airborne dust in the Martian atmosphere is primarily composed by composite silicate particles containing one or more highly magnetic minerals as a minor constituent, this minor constituent probably being dominated by the mineral maghemite (gamma-Fe2O3). The ultimate goal of the magnetic properties experiments on the Mars Exploration Rover mission is to provide some information/constraints on whether the dust is formed by volcanic, meteoritic, aqueous, or other processes. In detail, the objectives are: a) To identify the magnetic mineral(s) in the dust, soil and rocks on Mars. b) To establish if the magnetic material is present in the form of nanosized (d < 10 nm) superparamagnetic crystallites embedded in the micrometer sized airborne dust part icles. c) To establish if the magnets are culling a subset of strongly magnetic particles or if essentially all particles of the airborne dust are sufficiently magnetic to be attracted by the magnets. d) Detect compositional differences between the airborne dust and the soil and rock sites which are investigated at two landing sites. To accomplish these goals the Mars Exploration Rovers each carry a set of permanent magnets of several different strengths and sizes. Each magnet has its own specific objective.

Hviid, S. F.↗

Programmable Aperture with MEMS Microshutter Arrays

A microshutter array (MSA) has been developed for use as an aperture array for multi-object selections in James Webb Space Telescope (JWST) technology. Light shields, molybdenum nitride (MoN) coating on shutters, and aluminum/aluminum oxide coatings on interior walls are put on each shutter for light leak prevention, and to enhance optical contrast. Individual shutters are patterned with a torsion flexure that permits shutters to open 90 deg. with a minimized mechanical stress concentration. The shutters are actuated magnetically, latched, and addressed electrostatically. Also, micromechanical features are tailored onto individual shutters to prevent stiction. An individual shutter consists of a torsion hinge, a shutter blade, a front electrode that is coated on the shutter blade, a backside electrode that is coated on the interior walls, and a magnetic cobalt-iron coating. The magnetic coating is patterned into stripes on microshutters so that shutters can respond to an external magnetic field for the magnetic actuation. A set of column electrodes is placed on top of shutters, and a set of row electrodes on sidewalls is underneath the shutters so that they can be electrostatically latched open. A linear permanent magnet is aligned with the shutter rows and is positioned above a flipped upside-down array, and sweeps across the array in a direction parallel to shutter columns. As the magnet sweeps across the array, sequential rows of shutters are rotated from their natural horizontal orientation to a vertical open position, where they approach vertical electrodes on the sidewalls. When the electrodes are biased with a sufficient electrostatic force to overcome the mechanical restoring force of torsion bars, shutters remain latched to vertical electrodes in their open state. When the bias is removed, or is insufficient, the shutters return to their horizontal, closed positions. To release a shutter, both the electrode on the shutter and the one on the back wall where the shutter sits are grounded. The shutters with one or both ungrounded electrodes are held open. Sub-micron bumps underneath light shields and silicon ribs on back walls are the two features to prevent stiction. These features ensure that the microshutter array functions properly in mechanical motions. The MSA technology can be used primarily in multi-object imaging and spectroscopy, photomask generation, light switches, and in the stepper equipment used to make integrated circuits and MEMS (microelectromechanical systems) devices.

Moseley, Samuel↗

SIX EPU Antiparallel Study: Estimating mechanical and magnetic performance of the distorted 3.5m EPU57 in antiparallel mode

The 3.5m long SIX EPU with 57 mm period shown schematically was manufactured to NSLS2 specification by Kyma of Italy. That specification called for operation to be limited to parallel mode. In parallel mode each of two diagonally opposing permanent magnet array quadrants drive in the same direction along its respective longitudinal axis by a half period relative to its adjacent fixed array quadrant. As such, at maximum shift the array pairs are only 180 degrees out of phase.

36 MATERIALS SCIENCE↗

Refocusing of the spent axisymmetric beam in klystron tubes

Analytic methods were developed and employed to optimize the magnetic field transition region between the output interaction gap of a klystron and a multi-stage depressed potential electrostatic beam collector, in order to enhance the power conversion efficiency of satellite-borne broadcast transmitters. Permanent magnet structures were designed to provide the magnetic field distributions required to expand and recollimate the spent electron beam of the power amplifier klystron for proper entry into the beam collector. These design criteria for magnetic field distributions for expanding and recollimating spent-beam electrons for optimal entry into a multi-stage depressed potential collector are generally applicable to traveling-wave tubes as well as klystrons.

Branch, G. M.↗

CoxC nanorod magnets: Highly magnetocrystalline anisotropy with lower Curie temperature for potential applications

Magnetic CoxC nanorods with larger magnetocrystalline anisotropy of 5 x 10(5) J/m(3) as well as larger coercivity and lower Curie temperature are introduced. The particles have an average diameter of 8 nm and shows three different magnetic behaviors. The sample shows ferromagnetism up to 400 K, superparamagnetism at temperature > 400 K and <T-C (465 K) and paramagnetism above 465 K. Such different behaviors open the door for various applications such as permanent magnets, magnetic sensors and contract agent for magnetic resonance imaging. (c) 2013 Elsevier B.V. All rights reserved.

El-Gendy, AA↗

Gravity Slides With Magnetic Braking

Slides with magnetic braking enable safe emergency descent from tall buildings, fire-truck ladders, towers, and like. According to concept, slide includes sled that moves along stationary aluminum track tilted against top of building. Sled holds set of permanent magnets at preset small distance from surface of track. Passenger stands on, sits on, or strapped to platform on sled. Release device at top of slide holds sled in place until passenger prepared for descent.

Goodrick, Thomas F.↗

Magnetization processes in core/shell exchange-spring structures.

The magnetization reversal processes in cylindrical and spherical soft core/hard shell exchange-spring structures are investigated via the analytical nucleation theory, and are verified with numerical micromagnetic simulations. At small core sizes, the nucleation of magnetic reversal proceeds via the modified bulging mode, where the transverse component of the magnetization is only semi-coherent in direction and the nucleation field contains a contribution from self-demagnetization. For large core sizes, the modified curling mode, where the magnetization configuration is vortex-like, is favored at nucleation. The preference for the modified curling mode is beneficial in that the fluxclosure allows cylindrical and spherical core/shell exchange-spring elements to be densely packed into bulk permanent magnets without affecting the nucleation field, thereby offering the potential for high energy product.

Jiang, J. S.↗

Additively Manufactured NdFeB Polyphenylene Sulfide Halbach Magnets to Generate Variable Magnetic Fields for Neutron Reflectometry

Halbach arrays are the most efficient closed structures for generating directed magnetic fields and gradients, and are widely used in various electric machines. We utilized fused deposition modeling-based Big Area Additive Manufacturing technology to print customized, compensated concentric Halbach array rings, using polyphenylene sulfide-bonded NdFeB permanent magnets for polarized neutron reflectometry. The Halbach rings could generate a 0 ≤ B ≤ 0.30 T field, while preserving 90% polarization of an axial neutron beam. Polarized neutron beams are used to study a wide range of structural and magnetic phenomena spanning physics, chemistry, and biology. In this study, we demonstrate the effectiveness of additive manufacturing for producing prototype Halbach arrays, characterize their magnetic properties, and generated magnetic fields, and discuss the conservation of neutron beam polarization as a function of magnetic field.

36 MATERIALS SCIENCE↗

Fabrication and characterization of net-shaped iron nitride-amine-epoxy soft magnetic composites

Soft magnetic composites (SMCs) offer a promising alternative to electrical steels and soft ferrites in high performance motors and power electronics. They are ideal for incorporation into passive electronic components such as inductors and transformers, which require a non-permanent magnetic core to rapidly switch magnetization. As a result, there is a need for materials with the right combination of low coercivity, low magnetic remanence, high relative permeability, and high saturation magnetization to achieve these goals. Iron nitride is an attractive soft magnetic material for incorporation into an amine/epoxy resin matrix. This permits the synthesis of net-shaped SMCs using a “bottom-up” approach for overcoming the limitations of current state-of-the-art SMCs made via conventional powder metal processing techniques. In this work we present the fabrication of various net-shaped, iron nitride-based SMCs using two different amine/epoxy resin systems and their magnetic characterization. The maximum volume loading of iron nitride reached was ~77% via hot pressing, which produced SMCs with a saturation magnetic polarization (J s ) of ~0.9 T, roughly 2–3 times the J s of soft ferrites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical position measurement for a Large Gap Magnetic Suspension System

This paper describes the design of an optical position measurement system which is being built as part of the NASA Langley Large Gap Magnetic Suspension System (LGMSS). The LGMSS is a five degree-of-freedom, large-gap magnetic suspension system which is being built for Langley Research Center as part of the Advanced Controls Test Facility (ACTF). The LGMSS consists of a planar array of electromagnets which levitate and position a cylindrically shaped model containing a permanent magnet core. The optical position measurement system provides information on the location and orientation of the model to the LGMSS control system to stabilize levitation of the model.

Welch, Sharon S.↗

Simulation of the Charged Particle Deflection From the Sweeping Magnet Array in the Lunar Environment Heliospheric X-Ray Imager

The Lunar Environment heliospheric X-ray Imager (LEXI) is an instrument built to image x-rays from solar wind charge exchange in Earth’s magneto sheath. Monitoring the position of the magnetopause at the inner boundary of the magneto sheath allows us to understand how magnetic reconnection regulates how energy from the solar wind is deposited into Earth’s magnetosphere. LEXI is part of an upcoming lunar lander mission set to land in Mare Crisium. To repel unwanted charged particles, the instrument carries a permanent magnet array composed of 48 neodymium magnets. The array was designed to maximize charged particle deflection while minimizing stray magnetic fields, which could impact other instruments or spacecraft operation. A Runge–Kutta-based fully kinetic particle tracing model was created to evaluate the effectiveness of LEXI’s unique charged particle deflector array. Combined with the other particle suppression measures of the instrument, including physical structures and filters, the simulations show proton and electron transmission to the LEXI detector is expected to be sufficiently reduced to allow successful imaging. The flexible simulation model can be generalized to be used in examining the magnetic deflector array effectiveness of other instruments whose signals could be compromised by unwanted charged particle contamination.

Space environment effects↗

Rotary electric device

An electric motor is described with a low speed shaft that rotates at a speed much slower than the speed of a high speed shaft. It is comprised of a stator having a cylindrical bore with a longitudinal axis and a rotor that carries the low speed shaft which rotates in the bore eccentrically about the axis. There is contact and no magnetic gap between a relatively small portion of the rotor periphery and the periphery of the bore. A magnetic field, rotating at the speed of the high speed shaft, is applied to the periphery of the bore. The field has longitudinally extending magnetic field components of opposite polarity so that around approximately 180 deg of the bore the field extends in one direction, while around the other 180 deg of the bore the field extends in the opposite direction. The rotor includes permanent magnet pole faces at opposite ends of the bore.

Madey, J. M.↗

Spacelab energetic ion mass spectrometer

Basic design criteria are given for an ion mass spectrometer for use in studying magnetospheric ion populations. The proposed instrument is composed of an electrostatic analyzer followed by a magnetic spectrometer and simultaneously measures the energy per unit and mass per unit charge of the ion species. An electromagnet is used for momentum analysis to extend the operational energy range over a much wider domain than is possible with the permanent magnets used in previous flights. The energetic ion source regions, ion energization mechanisms, field line tracing, coordinated investigations, and orbit considerations are discussed and operations of the momentum analyzer and of the electrostatic energy analyzer are examined.

Whalen, B. A.↗

SU-E-J-38: Comparison of 6MV Photon Dose in a Perpendicular and Parallel Magnetic Field

Purpose: Integrating a linac with an MRI system would allow for real time tumour tracking however the patient will be irradiated in the presence of a magnetic field. The present study experimentally investigates the magnetic field effects on entrance, exit, and interface dose for both transverse and parallel magnetic fields. Methods: Polystyrene was used to construct a set of phantoms for Gafchromic film measurements. One phantom had an adjustable air gap and four other phantoms had one surface at various angles. The linac-MR prototype consisting of a biplanar permanent magnet coupled to a linac was used for the transverse magnetic field measurements. A couple of solenoid electromagnets, stacked on top of each other and irradiated along their bore, were used for the parallel field measurements. Results: All doses are relative to no magnetic field. The transverse magnetic field reduced the entrance dose for all surface angles by strongly deflecting the contaminant electrons. The exit dose in a transverse magnetic field was found to be significantly higher. The entrance dose with a parallel magnetic field present is higher due to the contaminant electrons being concentrated within the beam area. The air gap phantom measurements, done in a transverse magnetic field, show a significant increase of the dose at the proximal side of the air gap and a decrease at the distal side. The measurements, done in the parallel magnetic field, show the concentration of secondary electrons in the air gap. Conclusion: The radiation dose measurements of a 6MV beam in a parallel and transverse magnetic field presented here are currently being replicated using Monte Carlo simulations. This verified Monte Carlo system could provide the dose calculation basis for future linac-MR systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Iterative Magnetic/Structural Simulation of a MEMS Micro-shutter

A finite element model has been created that simulates the magnetic actuation of a cobalt-iron covered, 0.5micron thick, silicon nitride micro-shutter. The micro-shutter will be used as a transmissible filter in a space-based Multi-object Spectrograph (MOS). A laminated tri-pole permanent magnet is scanned across an array of shutters. The applied magnetic force twists the shutter's torsion hinge and actuates the shutter from the closed, 0 degree position, to the open, 90 degree position. A sequential analysis method was selected. This method uses the interaction between the magnetic and structural fields and is accomplished via the load vectors. The simulation results are compared to experimental measurements of fabricated micro-shutter devices.

Khaskia, Abed M.↗

Improvement of persistent magnetic field trapping in bulk Y-Ba-Cu-O superconductors

For type-II superconductors, magnetic field can be trapped due to persistent internal supercurrent. Quasi-persistent magnetic fields near 2 T at 60 K (and 1.4 T at 77 K) have been measured in minimagnets made of proton-irradiated melt-textured Y-Ba-Cu-O (MT-Y123) samples. Using the trapping effect, high-field permanent magnets with dipole, quadrupole, or more complicated configurations can be made of existing MT-Y123 material, thus bypassing the need for high-temperature superconductor (HTS) wires. A phenomenological current model has been developed to account for the trapped field intensity and profile in HTS samples. This model is also a guide to select directions of materials development to further improve field trapping properties. General properties such as magnetic field intensities, spatial distributions, stabilities, and temperature dependence of trapped field are discussed.

Chen, In-Gann↗