Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Portability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Field Test Report: NETL Portable Raman Gas Composition Monitor Initial Industrial tests at NETL and General Electric (GE)

NETL has developed new technology which enables the use of Raman spectroscopy in the real-time measurement of gas mixtures. This technology uses a hollow reflective metal-lined capillary waveguide as a gas sampling cell which contains the sample gas, and efficiently collects optical Raman scattering from the gas sample, for measurement with a miniature spectrometer. The result is an optical Raman “fingerprint” for each gas which is tens or hundreds of times larger than that which can be collected with conventional free-space optics. In this manner, the new technology exhibits a combination of measurement speed and accuracy which is unprecedented for spontaneous Raman measurements of gases. This makes the system especially well-suited to gas turbine engine control based on a-priori measurement of incoming fuel composition. The system has been developed to produce a measurement of all of the common components of natural gas, including the lesser nitrogen, oxygen, carbon-dioxide, and carbon monoxide diluents to better than 1% concentration accuracy each second. The objective of this task under CRADA 10-N100 was to evaluate the capability of a laser Raman capillary gas sensor for combustion fuels. A portable version of the Raman gas sensor, constructed at NETL, was used for field-trials conducted in a cooperative research effort at a GE facility. Testing under the CRADA was performed in 5 parts. Parts 1-4 were successful in testing of the Raman Gas Composition Monitor with bottled calibration gases, and in continuous monitoring of several gas streams at low pressure, in comparison with an online mass spectrometer. In part 5, the Raman Gas Composition Monitor was moved outdoors for testing with high pressure gas supplies. Some difficulties were encountered during industrial testing including the condensation of heavy hydrocarbons inside the sample cell (in part 5), communication with the GE data collection system, as well as some drift in the optical noise background. The difficulties with liquid contaminants will be overcome through the use of prodigious sample-cell heating and additional line filtration including liquid ingress-protection. The communication problem was resolved through site-specific troubleshooting of the MODBUS data tags.

25 ENERGY STORAGE↗

Field Test Report: NETL Portable Raman Gas Composition Monitor - Initial Industrial tests at NETL and General Electric (GE)

NETL has developed new technology which enables the use of Raman spectroscopy in the real-time measurement of gas mixtures. This technology uses a hollow reflective metal-lined capillary waveguide as a gas sampling cell which contains the sample gas, and efficiently collects optical Raman scattering from the gas sample, for measurement with a miniature spectrometer. The result is an optical Raman “fingerprint” for each gas which is tens or hundreds of times larger than that which can be collected with conventional free-space optics. In this manner, the new technology exhibits a combination of measurement speed and accuracy which is unprecedented for spontaneous Raman measurements of gases. This makes the system especially well-suited to gas turbine engine control based on a-priori measurement of incoming fuel composition. The system has been developed to produce a measurement of all of the common components of natural gas, including the lesser nitrogen, oxygen, carbon-dioxide, and carbon monoxide diluents to better than 1% concentration accuracy each second. The objective of this task under CRADA 10-N100 was to evaluate the capability of a laser Raman capillary gas sensor for combustion fuels. A portable version of the Raman gas sensor, constructed at NETL, was used for field-trials conducted in a cooperative research effort at a GE facility. Testing under the CRADA was performed in 5 parts. Parts 1-4 were successful in testing of the Raman Gas Composition Monitor with bottled calibration gases, and in continuous monitoring of several gas streams at low pressure, in comparison with an online mass spectrometer. In part 5, the Raman Gas Composition Monitor was moved outdoors for testing with high pressure gas supplies. Some difficulties were encountered during industrial testing including the condensation of heavy hydrocarbons inside the sample cell (in part 5), communication with the GE data collection system, as well as some drift in the optical noise background. The difficulties with liquid contaminants will be overcome through the use of prodigious sample-cell heating and additional line filtration including liquid ingress-protection. The communication problem was resolved through site-specific troubleshooting of the MODBUS data tags.

25 ENERGY STORAGE↗

Single-pixel reconstructive mid-infrared micro-spectrometer

Miniaturized spectrometers in the mid-infrared (MIR) are critical in developing next-generation portable electronics for advanced sensing and analysis. The bulky gratings or detector/filter arrays in conventional micro-spectrometers set a physical limitation to their miniaturization. In this work, we demonstrate a single-pixel MIR micro-spectrometer that reconstructs the sample transmission spectrum by a spectrally dispersed light source instead of spatially grated light beams. The spectrally tunable MIR light source is realized based on the thermal emissivity engineered via the metal-insulator phase transition of vanadium dioxide (VO 2 ). We validate the performance by showing that the transmission spectrum of a magnesium fluoride (MgF 2 ) sample can be computationally reconstructed from sensor responses at varied light source temperatures. With potentially minimum footprint due to the array-free design, our work opens the possibility where compact MIR spectrometers are integrated into portable electronic systems for versatile applications.

47 OTHER INSTRUMENTATION↗

DECOMMISSIONING AND ENVRIONMENTAL CLEANUP OF SMALL ARMS TRAINING FACILITY

USDOE performed a (CERCLA) non-time critical removal (NTCR) action at the Small Arms Training Area (SATA) Site Evaluation Area (SEA) located at the Savannah River Site (SRS), in Aiken, South Carolina. From 1951 to May 2010, the SATA was used as a small weapons practice and qualifying firing range. The SATA consisted of 870.1 ha (2,150 ac) of woodlands and open field, of which approximately 2.9 ha (7.3 ac) were used as a firing range. The SATA facility was comprised of three small arms ranges (one static and two interactive), storage buildings for supplies, a weapons cleaning building, and a control building. Additionally, a 113- m (370-ft) long earthen berm was used as a target backstop during live-fire exercises. The berm soils accumulated a large amount of spent lead bullets in the berm face during the facilities 59- years of operation. The accumulation of lead was such that soil concentrations exceeded the U.S. Environmental Protection Agency (USEPA) residential and industrial worker regional screening levels (RSLs). The RSL threshold values are based on standardized exposure scenarios that estimate contaminant concentrations in soil that the USEPA considers protective of humans over a lifetime. For the SATA facility, lead was present in soil at concentrations that exceed both the current residential (400 mg/kg) and industrial (800 mg/kg) RSLs. In addition, the concentration of lead in the soil exceeded the Toxicity Characteristic Leaching Procedure (TCLP) (40 Code of Federal Regulations [CFR] 261.24) regulatory limit. The TCLP analysis simulates landfill conditions and is designed to determine the mobility of contaminants in waste. In addition, a principal threat source material (PTSM) evaluation, human health risk assessment (HHRA), and contaminant migration (CM) analysis were conducted to evaluate soil contamination at the SATA SEA. This evaluation determined that there were no contaminants present that constitute PTSM and the CM analysis revealed that no constituents posed a migration risk to groundwater. The NTCR action involved removal of approximately 12,092 m3 (15,816 yd3) of spent bullets and lead-impacted soil and off-site disposal. The removal action included soils from the berm area, a fill area that received scraped soils from the berm, and soil from a drainage ditch located on the edge of the berm area. Also included in the removal action was a mixture of soil, concrete, and asphalt from the other three range areas. Under this action, 11,796 m3 (15,429 yd3) of hazardous waste and impacted soil were removed from the SATA and transported to a permitted hazardous waste disposal facility (Lone Mountain Facility in Oklahoma) and 296 m3 (387 yd3) of nonhazardous waste (primarily concrete debris) were removed and transported to a local solid waste landfill for disposal. During the excavation process, the extent was continuously assessed through the use of a hand-held, field-portable X-ray fluorescence unit with results verified using confirmation sampling with certified laboratory analysis. Following the completion of the excavation and confirmation sampling, final contouring, grading, and establishment of vegetative cover was performed to stabilize the affected areas. The NTCR action began on August 17, 2010, and mechanical completion was achieved on April 27, 2011. The selected removal action met the removal action objectives (RAOs), is protective of human health and the environment both in the short- and long-term, was successful in removing potential ecological risks, and is protective of surface water and groundwater. Furthermore, the selected NTCR action met residential cleanup goals and resulted in the release of the SEA from restricted use contributing to the overall footprint reduction at SRS.

54 ENVIRONMENTAL SCIENCES↗

Decommissioning and Environmental Cleanup of a Small Arms Training Facility - 13225

US DOE performed a (CERCLA) non-time critical removal (NTCR) action at the Small Arms Training Area (SATA) Site Evaluation Area (SEA) located at the Savannah River Site (SRS), in Aiken, South Carolina. From 1951 to May 2010, the SATA was used as a small weapons practice and qualifying firing range. The SATA consisted of 870.1 ha (2,150 ac) of woodlands and open field, of which approximately 2.9 ha (7.3 ac) were used as a firing range. The SATA facility was comprised of three small arms ranges (one static and two interactive), storage buildings for supplies, a weapons cleaning building, and a control building. Additionally, a 113- m (370-ft) long earthen berm was used as a target backstop during live-fire exercises. The berm soils accumulated a large amount of spent lead bullets in the berm face during the facilities 59- years of operation. The accumulation of lead was such that soil concentrations exceeded the U.S. Environmental Protection Agency (USEPA) residential and industrial worker regional screening levels (RSLs). The RSL threshold values are based on standardized exposure scenarios that estimate contaminant concentrations in soil that the USEPA considers protective of humans over a lifetime. For the SATA facility, lead was present in soil at concentrations that exceed both the current residential (400 mg/kg) and industrial (800 mg/kg) RSLs. In addition, the concentration of lead in the soil exceeded the Toxicity Characteristic Leaching Procedure (TCLP) (40 Code of Federal Regulations [CFR] 261.24) regulatory limit. The TCLP analysis simulates landfill conditions and is designed to determine the mobility of contaminants in waste. In addition, a principal threat source material (PTSM) evaluation, human health risk assessment (HHRA), and contaminant migration (CM) analysis were conducted to evaluate soil contamination at the SATA SEA. This evaluation determined that there were no contaminants present that constitute PTSM and the CM analysis revealed that no constituents posed a migration risk to groundwater. The NTCR action involved removal of approximately 12,092 m{sup 3} (15,816 yd{sup 3}) of spent bullets and lead-impacted soil and off-site disposal. The removal action included soils from the berm area, a fill area that received scraped soils from the berm, and soil from a drainage ditch located on the edge of the berm area. Also included in the removal action was a mixture of soil, concrete, and asphalt from the other three range areas. Under this action, 11,796 m{sup 3} (15,429 yd{sup 3}) of hazardous waste and impacted soil were removed from the SATA and transported to a permitted hazardous waste disposal facility (Lone Mountain Facility in Oklahoma) and 296 m{sup 3} (387 yd{sup 3}) of nonhazardous waste (primarily concrete debris) were removed and transported to a local solid waste landfill for disposal. During the excavation process, the extent was continuously assessed through the use of a hand-held, field-portable X-ray fluorescence unit with results verified using confirmation sampling with certified laboratory analysis. Following the completion of the excavation and confirmation sampling, final contouring, grading, and establishment of vegetative cover was performed to stabilize the affected areas. The NTCR action began on August 17, 2010, and mechanical completion was achieved on April 27, 2011. The selected removal action met the removal action objectives (RAOs), is protective of human health and the environment both in the short- and long-term, was successful in removing potential ecological risks, and is protective of surface water and groundwater. Furthermore, the selected NTCR action met residential cleanup goals and resulted in the release of the SEA from restricted use contributing to the overall footprint reduction at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oxygen Loss in Layered Oxide Cathodes for Li-Ion Batteries: Mechanisms, Effects, and Mitigation

Layered lithium transition metal oxides derived from LiMO 2 (M = Co, Ni, Mn, etc.) have been widely adopted as the cathodes of Li-ion batteries for portable electronics, electric vehicles, and energy storage. Oxygen loss in the layered oxides is one of the major factors leading to cycling-induced structural degradation and its associated fade in electrochemical performance. Herein, we review recent progress in understanding the phenomena of oxygen loss and the resulting structural degradation in layered oxide cathodes. We first present the major driving forces leading to the oxygen loss and then describe the associated structural degradation resulting from the oxygen loss. Here, we follow this analysis with a discussion of the kinetic pathways that enable oxygen loss, and then we address the resulting electrochemical fade. Finally, we review the possible approaches toward mitigating oxygen loss and the associated electrochemical fade as well as detail novel analytical methods for probing the oxygen loss.

36 MATERIALS SCIENCE↗

Scintillation light detection in polycrystalline diamond using single photon detectors

Here, this study investigates the scintillation properties of polycrystalline diamond for particle detection applications, particularly in neutron and alpha radiation environments. Polycrystalline diamonds provide a cost-effective alternative to monocrystalline diamonds while retaining essential detection properties. Photoluminescence measurements were performed to analyze emission spectra, revealing distinct characteristics based on impurity content and crystallinity. Scintillation responses were assessed using Silicon Photomultipliers (SiPMs), demonstrating the capability of polycrystalline diamond powders to respond to alpha irradiation, albeit with reduced resolution compared to traditional scintillators. A prototype neutron detector was developed by combining diamond powder with neutron-sensitive 6 LiF, and its performance was evaluated through experimental testing and Geant4 simulations. The findings indicate that polycrystalline diamond-based detectors can achieve significant detection efficiency while remaining insensitive to gamma radiation, offering potential for portable neutron detection applications.

47 OTHER INSTRUMENTATION↗

Module-OT: A Turnkey Solution for Securing Energy Systems

The Modular Security Apparatus for Managing Distributed Cryptography for Command-and-Control Messages on Operational Technology Networks (Module-OT) is a flexible and lightweight solution for grid-edge devices focusing on end-to-end security. It is a bump- in- the-wire solution acting as a secure conduit for data between devices or systems across a network. It improves the cybersecurity posture of DER systems by providing authentication, authorization, and data integrity to secure DER communications. Additionally, it performs key management, provides data security through whitelisting Internet Protocol addresses and ports, blocks unauthorized connections, controls user access, and allows serial or Ethernet connections for added flexibility. The core software is portable to various Linux-based operating systems and is developed to be customized by the developer and researcher communities. Module-OT has been validated in the lab, has been demonstrated at a 500-KW PV-plus-storage site, and has been proven ready to secure operational technology devices. Its core functionality meets current standards, including validation procedures of the NIST Cryptographic Algorithm Validation Program (CAVP) and the Federal Information Processing Standard (FIPS 140-2). Because of its capability to provide an accessible and affordable option for stepping up security across modern energy systems, Module-OT can serve as an effective technological option to standardize cybersecurity moving forward.

cryptography↗

Causal Analysis of the Inadvertent Contact with an Uncontrolled Electrical Hazardous Energy Source (120 Volts AC)

On September 25, 2013, a Health Physics Technician (HPT) was performing preparations to support a pneumatic transfer from the HFEF Decon Cell to the Room 130 Glovebox in HFEF, per HFEF OI 3165 section 3.5, Field Preparations. This activity involves an HPT setting up and climbing a portable ladder to remove the 14-C meter probe from above ball valve HBV-7. The HPT source checks the meter and probe and then replaces the probe above HBV-7, which is located above Hood ID# 130 HP. At approximately 13:20, while reaching past the HBV-7 valve position indicator switches in an attempt to place the 14-C meter probe in the desired location, the HPT’s left forearm came in contact with one of the three sets of exposed terminals on the valve position indication switches for HBV 7. This resulted in the HPT receiving an electrical shock from a 120 Volt AC source. Upon moving the arm, following the electrical shock, the HPT noticed two exposed electrical connections on a switch. The HPT then notified the HFEF HPT Supervisor, who in turn notified the MFC Radiological Controls Manager and HFEF Operations Manager of the situation. Work was stopped in the area and the hazard was roped off and posted to prevent access to the hazard. The HPT was escorted by the HPT Supervisor to the MFC Dispensary and then preceded to CFA medical for further evaluation. The individual was evaluated and released without any medical restrictions. Causal Factor (Root Cause) A3B3C01/A5B2C08: - Knowledge based error/Attention was given to wrong issues - Written Communication content LTA, Incomplete/situation not covered The Causal Factor (root cause) was attention being given to the wrong issues during the creation, reviews, verifications, and actual performance of HFEF OI-3165, which covers the need to perform the weekly source check and ensure placement of the probe prior to performing a “rabbit” transfer. This resulted in the hazard not being identified and mitigated in the procedure. Work activities with in HFEF-OI-3165 placed the HPT in proximity of an unmitigated hazard directly resulting in this event. Contributing Factor A3B3C04/A4B5C04: - Knowledge Based Error, LTA Review Based on Assumption That Process Will Not Change - Change Management LTA, Risks/consequences associated with change not adequately reviewed/assessed Prior to the pneumatic system being out of service, the probe and meter were not being source checked together. The source check issue was identified and addressed during the period of time when the system was out of service. The corrective actions for this issue resulted in the requirement that a meter and probe be source checked together as it is intended to be used. This changed the activity and required an HPT to weekly, when in use, remove and install the probe from above HBV-7 to meet the requirement of LRD 15001 Part 5 Article 551.5. Risks and consequences associated with this change were not adequately reviewed or assessed. Failure to identify the hazard associated with this change directly contributed to this event.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inference-Engine v0.1.0

Given a pre-trained neural network, Inference-Engine performs maps network inputs to outputs by executing the forward pass through the provided network. Although the predominant programming language for machine-learning is Python, most high-performance computing (HPC) applications are written in Fortran, C, or C++. Inference-Engine aims to support HPC programs and is written in Fortran, a language with a large feature set supporting interoperability with C. This software exposes concurrency in a portable way by using standard language features that some modern Fortran compilers can exploit with various optimizations, including offloading computation to a Graphics Processing Unit (GPU). In particular, this software makes extensive use of Fortran's "do concurrent" parallel loop construct, implicitly parallel array statements, and pure procedures that can be invoked inside "do concurrent" blocks. Inference-Engine also supports dynamic choice of inference methods at runtime. Two current options include one method that uses Fortran's "dot_product" intrinsic function inside "do concurrent" blocks and another method that instead uses Fortran' "matmul" array intrinsic function. We plan to investigate automatic compiler offloading of "do concurrent" calculations to GPUs and compile-time substitution of optimized libraries such as the Basic Linear Algebra Library (BLAS) for "matmul" invocations. We also envision the potential for the choice of which method to use could happen at program launch based on in situ performance measurements on any given platform.

Rouson, Damian↗

In crystallo optical spectroscopy (icOS) as a complementary tool on the macromolecular crystallography beamlines of the ESRF

The current version of the Cryobench in crystallo optical spectroscopy facility of the ESRF is presented. The diverse experiments that can be performed at the Cryobench are also reviewed. The analysis of structural data obtained by X-ray crystallography benefits from information obtained from complementary techniques, especially as applied to the crystals themselves. As a consequence, optical spectroscopies in structural biology have become instrumental in assessing the relevance and context of many crystallographic results. Since the year 2000, it has been possible to record such data adjacent to, or directly on, the Structural Biology Group beamlines of the ESRF. A core laboratory featuring various spectrometers, named the Cryobench, is now in its third version and houses portable devices that can be directly mounted on beamlines. This paper reports the current status of the Cryobench, which is now located on the MAD beamline ID29 and is thus called the ID29S-Cryobench (where S stands for ‘spectroscopy’). It also reviews the diverse experiments that can be performed at the Cryobench, highlighting the various scientific questions that can be addressed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Portable nitrous oxide sensor for understanding agricultural and soil emissions

Nitrous oxide (N2O) is the third most important greenhouse gas (GHG,) with an atmospheric lifetime of ~114 years and a global warming impact ~300 times greater than that of carbon dioxide. The main cause of nitrous oxide’s atmospheric increase is anthropogenic emissions, and over 80% of the current global anthropogenic flux is related to agriculture, including associated land-use change. An accurate assessment of N2O emissions from agriculture is vital not only for understanding the global N2O balance and its impact on climate but also for designing crop systems with lower GHG emissions. Such assessments are currently hampered by the lack of instrumentation and methodologies to measure ecosystem-level fluxes at appropriate spatial and temporal scales. Southwest Sciences and Princeton University are developing and testing new open-path eddy covariance instrumentation for continuous and fast (10 Hz) measurement of nitrous oxide emissions. An important advance, now being implemented, is the use of new mid-infrared laser sources that enable the development of exceptionally low power (<10 W) compact instrumentation that can be used even in remote sites lacking in power. The instrumentation will transform the ability to measure and understand ecosystem-level nitrous oxide fluxes. The Phase II results included successful extended field testing of prototype flux instruments, based on quantum cascade lasers, in collaboration with Michigan State University. Results of these tests demonstrated a flux detection limit of 5 µg m-2 s-1 and showed excellent agreement and correlation with measurements using chamber techniques. Initial tests of an instrument using an interband cascade laser (ICL) were performed, verifying that an order of magnitude reduction in instrument power requirements can be realized. These results point toward future improvements and testing leading to introduction of a commercial open path instrument for N2O flux measurements that is truly portable and cost-effective. The technology developed on this project is especially groundbreaking as it could be widely applied across FLUXNET and AmeriFlux sites (>1200 worldwide) for direct measurements of N2O exchange. The technology can be more broadly applied to gas monitoring requirements in industry, environmental monitoring, health and safety, etc.

47 OTHER INSTRUMENTATION↗

Optimizing Blocking and Nonblocking Reduction Operations for Multicore Systems: Hierarchical Design and Implementation

Many scientific simulations, using the Message Passing Interface (MPI) programming model, are sensitive to the performance and scalability of reduction collective operations such as MPI Allreduce and MPI Reduce. These operations are the most widely used abstractions to perform mathematical operations over all processes that are part of the simulation. In this work, we propose a hierarchical design to implement the reduction operations on multicore systems. This design aims to improve the efficiency of reductions by 1) tailoring the algorithms and customizing the implementations for various communication mechanisms in the system 2) providing the ability to configure the depth of hierarchy to match the system architecture, and 3) providing the ability to independently progress each of this hierarchy. Using this design, we implement MPI Allreduce and MPI Reduce operations (and its nonblocking variants MPI Iallreduce and MPI Ireduce) for all message sizes, and evaluate on multiple architectures including InfiniBand and Cray XT5. We leverage and enhance our existing infrastructure, Cheetah, which is a framework for implementing hierarchical collective operations to implement these reductions. The experimental results show that the Cheetah reduction operations outperform the production-grade MPI implementations such as Open MPI default, Cray MPI, and MVAPICH2, demonstrating its efficiency, flexibility and portability. On Infini- Band systems, with a microbenchmark, a 512-process Cheetah nonblocking Allreduce and Reduce achieves a speedup of 23x and 10x, respectively, compared to the default Open MPI reductions. The blocking variants of the reduction operations also show similar performance benefits. A 512-process nonblocking Cheetah Allreduce achieves a speedup of 3x, compared to the default MVAPICH2 Allreduce implementation. On a Cray XT5 system, a 6144-process Cheetah Allreduce outperforms the Cray MPI by 145%. The evaluation with an application kernel, Conjugate Gradient solver, shows that the Cheetah reductions speeds up total time to solution by 195%, demonstrating the potential benefits for scientific simulations.

Gorentla Venkata, Manjunath↗

Improved particle-flow event reconstruction with scalable neural networks for current and future particle detectors

Abstract Efficient and accurate algorithms are necessary to reconstruct particles in the highly granular detectors anticipated at the High-Luminosity Large Hadron Collider and the Future Circular Collider. We study scalable machine learning models for event reconstruction in electron-positron collisions based on a full detector simulation. Particle-flow reconstruction can be formulated as a supervised learning task using tracks and calorimeter clusters. We compare a graph neural network and kernel-based transformer and demonstrate that we can avoid quadratic operations while achieving realistic reconstruction. We show that hyperparameter tuning significantly improves the performance of the models. The best graph neural network model shows improvement in the jet transverse momentum resolution by up to 50% compared to the rule-based algorithm. The resulting model is portable across Nvidia, AMD and Habana hardware. Accurate and fast machine-learning based reconstruction can significantly improve future measurements at colliders.

Physics↗

Pulsed Neutron Measurments With A DT Neutron Generator for an Annular HEU Uranium Metal Casting

Measurements were performed with a single annular, stainless-steel-canned casting of uranium (93.17 wt% 235U) metal ( ~18 kg) to provide data to verify calculational methods for criticality safety. The measurements used a small portable DT generator with an embedded alpha detector to time and directionally tag the neutrons from the generator. The center of the time and directional tagged neutron beam was perpendicular to the axis of the casting. The radiation detectors were 1x1x6 in plastic scintillators encased in 0.635-cm-thick lead shields that were sensitive to neutrons above 1 MeV in energy. The detector lead shields were adjacent to the casting and the target spot of the generator was about 3.8 cm from the casting at the vertical center. The time distribution of the fission induced radiation was measured with respect to the source event by a fast (1GHz) processor. The measurements described in this paper also include time correlation measurements with a time tagged spontaneously fissioning 252Cf neutron source, both on the axis and on the surface of the casting. Measurements with both types of sources are compared. Measurements with the DT generator closely coupled with the HEU provide no more additional information than those with the Cf source closely coupled with the HEU and are complicated by the time and directionally tagged neutrons from the generator scattering between the walls and floor of the measurements room and the casting while still above detection thresholds.

Mihalczo, John T↗

Experiences with High-Level Programming Directives for Porting Applications to GPUs. In: Facing the Multicore--Challenge II, Lecture Notes in Computer Science.

HPC systems now exploit GPUs within their compute nodes to accelerate program performance. As a result, high-end application development has become extremely complex at the node level. In addition to restructuring the node code to exploit the cores and specialized devices, the programmer may need to choose a programming model such as OpenMP or CPU threads in conjunction with an accelerator programming model to share and manage the different node resources. This comes at a time when programmer productivity and the ability to produce portable code has been recognized as a major concern. In order to offset the high development cost of creating CUDA or OpenCL kernels, directives have been proposed for programming accelerator devices, but their implications are not well known. In this paper, we evaluate the state of the art accelerator directives to program several applications kernels, explore transformations to achieve good performance, and examine the expressivity and performance penalty of using high-level directives versus CUDA. We also compare our results to OpenMP implementations to understand the benefits of running the kernels in the accelerator versus CPU cores.

CUDA Implementation↗

Experiences with High-Level Programming Directives for Porting Applications to GPUs

HPC systems now exploit GPUs within their compute nodes to accelerate program performance. As a result, high-end application development has become extremely complex at the node level. In addition to restructuring the node code to exploit the cores and specialized devices, the programmer may need to choose a programming model such as OpenMP or CPU threads in conjunction with an accelerator programming model to share and manage the difference node resources. This comes at a time when programmer productivity and the ability to produce portable code has been recognized as a major concern. In order to offset the high development cost of creating CUDA or OpenCL kernels, directives have been proposed for programming accelerator devices, but their implications are not well known. In this paper, we evaluate the state of the art accelerator directives to program several applications kernels, explore transformations to achieve good performance, and examine the expressiveness and performance penalty of using high-level directives versus CUDA. We also compare our results to OpenMP implementations to understand the benefits of running the kernels in the accelerator versus CPU cores.

43 PARTICLE ACCELERATORS↗

Ultralightweight Power System for Human-Portable Linac-Based X-Ray Sources

Industrial human-portable X-ray sources are widely used by security, nuclear safeguard, and defense agencies. However, the employed sources have significant energy, dose, size, weight, and power (SWaP) limitations, greatly affecting their practical application. RF linear accelerators (linacs) can serve as a flexible, reliable, and robust type of X-ray source if they can match the size, weight, cost, and imaging performance requirements of conventional ones. One of the most critical elements affecting these parameters is the high-voltage pulsed power supply system or modulator, which can make the largest contribution to the total weight and dimensions of the accelerator. Here, in this article, we present the design and demonstration results of a novel ultra lightweight power system based on a 24-kV solid-state Marx modulator for a hand-portable 0.15–2.0-MeV Ku -band linac-based X-ray source.

47 OTHER INSTRUMENTATION↗