Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Composting in small laboratory pilots: Performance and reproducibility

Highlights: Black-Right-Pointing-Pointer We design an innovative small-scale composting device including six 4-l reactors. Black-Right-Pointing-Pointer We investigate the performance and reproducibility of composting on a small scale. Black-Right-Pointing-Pointer Thermophilic conditions are established by self-heating in all replicates. Black-Right-Pointing-Pointer Biochemical transformations, organic matter losses and stabilisation are realistic. Black-Right-Pointing-Pointer The organic matter evolution exhibits good reproducibility for all six replicates. - Abstract: Small-scale reactors (<10 l) have been employed in composting research, but few attempts have assessed the performance of composting considering the transformations of organic matter. Moreover, composting at small scales is often performed by imposing a fixed temperature, thus creating artificial conditions, and the reproducibility of composting has rarely been reported. The objectives of this study are to design an innovative small-scale composting device safeguarding self-heating to drive the composting process and to assess the performance and reproducibility of composting in small-scale pilots. The experimental setup included six 4-l reactors used for composting a mixture of sewage sludge and green wastes. The performance of the process was assessed by monitoring the temperature, O{sub 2} consumption and CO{sub 2} emissions, and characterising the biochemical evolution of organic matter. A good reproducibility was found for the six replicates with coefficients of variation for all parameters generally lower than 19%. An intense self-heating ensured the existence of a spontaneous thermophilic phase in all reactors. The average loss of total organic matter (TOM) was 46% of the initial content. Compared to the initial mixture, the hot water soluble fraction decreased by 62%, the hemicellulose-like fraction by 68%, the cellulose-like fraction by 50% and the lignin-like fractions by 12% in the final compost. The TOM losses, compost stabilisation and evolution of the biochemical fractions were similar to observed in large reactors or on-site experiments, excluding the lignin degradation, which was less important than in full-scale systems. The reproducibility of the process and the quality of the final compost make it possible to propose the use of this experimental device for research requiring a mass reduction of the initial composted waste mixtures.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accuracy of volume measurement using 3D ultrasound and development of CT-3D US image fusion algorithm for prostate cancer radiotherapy

Purpose: To evaluate the accuracy of measuring volumes using three-dimensional ultrasound (3D US), and to verify the feasibility of the replacement of CT-MR fusion images with CT-3D US in radiotherapy treatment planning. Methods: Phantoms, consisting of water, contrast agent, and agarose, were manufactured. The volume was measured using 3D US, CT, and MR devices. A CT-3D US and MR-3D US image fusion software was developed using the Insight Toolkit library in order to acquire three-dimensional fusion images. The quality of the image fusion was evaluated using metric value and fusion images. Results: Volume measurement, using 3D US, shows a 2.8 {+-} 1.5% error, 4.4 {+-} 3.0% error for CT, and 3.1 {+-} 2.0% error for MR. The results imply that volume measurement using the 3D US devices has a similar accuracy level to that of CT and MR. Three-dimensional image fusion of CT-3D US and MR-3D US was successfully performed using phantom images. Moreover, MR-3D US image fusion was performed using human bladder images. Conclusions: 3D US could be used in the volume measurement of human bladders and prostates. CT-3D US image fusion could be used in monitoring the target position in each fraction of external beam radiation therapy. Moreover, the feasibility of replacing the CT-MR image fusion to the CT-3D US in radiotherapy treatment planning was verified.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Defect Detection Model Development for Large Scale Thermoplastic Printing

Large-format additive manufacturing (LFAM) offers several advantages, including high throughput, cost-effective pellet-fed extrusion, and the capability to produce large-scale structures. The main pain points of LFAM include start and stops during the printing process, warpage, long layer times that lead to bead freezing, and bead separation due to shrinkage. These issues can lead to overfill, underfill and buildup of material in different sections of a print. This can lead to hidden defects embedded within the printed layers, or even ultimate failure of the printed structure. This ensures these defects can only be identified through nondestructive testing (NDT) inspection methods after printing, which can be timely and costly. Aligned Vision work specializes in 2D projectors with visual inspection systems and machine learning. Traditionally system is used for composite layup and layup inspections. In this work we used the LFAM system at Oak Ridge National Laboratory to create defect rich samples. The Aligned Vision inspection system then performed in-situ monitoring of the print process after each part was printed. This in-situ vision inspection system was used to develop a layer-by-layer inspection model that looks for overfill, underfill, and the buildup of defects using only a camera-based vision system. This leads to the assurance of high-quality production components.

36 MATERIALS SCIENCE↗

Towards in-situ certification of additively manufactured parts: the vital roles of physics-based and data-driven models

Certifying additively manufactured (AM) parts in-situ at the completion of a build is an enticing prospect, as it can help reduce the high costs associated with post-build testing and evaluation. However, achieving this goal presents significant challenges that may keep it aspirational for the foreseeable future. Nonetheless, incremental progress can pave the way forward. A critical aspect of in-situ certification involves continuous quality checking due to the random nature of the AM process and the difficulties in detecting defects or anomalies once layers are built over. While real-time in-situ monitoring strategies assisted by machine learning (ML) play a pivotal role in auditing part quality, they must ideally be supported by real-time (or near real-time) adaptive process control enabled by ML-assisted decision-making. By analyzing in-situ monitoring data in real-time (or near real- time) to dynamically adjust manufacturing parameters, such intervention can ensure AM parts are built to meet stringent certification standards. This can be achieved virtually by using high-fidelity performance models for the physical testing and evaluation tasks. In this short editorial, we discuss the key contributions made by data-driven and physics-based models in providing intelligence to the monitoring and process control tasks underpinning in-situ certification and in the simulation of the build’s performance under test and service conditions. While our focus lies in metal AM, the concepts discussed here are also relevant to other AM processes.

: In-situ monitoring↗

Individual Wave Detection and Tracking within a Rotating Detonation Engine through Computer Vision Object Detection applied to High-Speed Images

Known for their simplistic design and continuous detonation, rotating detonation engines (RDEs) constitute a majority of current pressure gain combustion (PGC) research efforts. Experimental RDE operation times have been continuously extended through the use of rig cooling techniques. As the window of observable behavior is expanded, and as the technology matures toward eventual integration within gas turbines, monitoring techniques must evolve to better match industrial diagnostics. High-speed image analysis techniques prove useful to capture and evaluate the unsteady detonation behavior within the RDE. Traditional image analysis techniques, however, require extensive processing times which prohibit simultaneous monitoring. To better address this problem, a computer vision object detection methodology is proposed to quickly detect individual detonation waves within a single down-axis image. Detonation waves are detected in individual images by the implemented computer vision method You Only Look Once (YOLO) object detection network. In order to detect detonation waves, the network must first be trained using RDE images of interest, for which each required phase of network development is outlined. Detection of waves is improved through proper treatment of the collected image set, variation of Intersection over Union (IoU) and confidence thresholding, and through a parametric study of annotation dimensions. Each detected wave is described by its location and rotational direction, and locations are tracked to calculate wave velocity across each frame, leading to a timestep resolution of 20 µs. Wave velocities are also calculated through a series of frames, leading to a suitable average velocity estimation using as few as 10 frames. Uncertainty analysis accounting for variation in camera framerate, pixel width and annotation centroid locations estimates a total uncertainty of ±4.3% for velocity calculations, using the smallest annotation boxes. This method offers great reductions in processing times, as a step toward real-time monitoring of detonation waves within an RDE. Improving on previous studies, this technique is impartial to wave modes not included in the original training set and calculates wave velocities independent of high-speed pressure data. The ability to isolate waves within predicted bounding boxes will likely facilitate analysis of pixel intensity variation as an estimation of wave strength in future work.

Johnson, Kristyn↗

Individual Wave Detection and Tracking within a Rotating Detonation Engine through Computer Vision Object Detection applied to High-Speed Images

Known for their simplistic design and continuous detonation, rotating detonation engines (RDEs) constitute a majority of current pressure gain combustion (PGC) research efforts. Experimental RDE operation times have been continuously extended through the use of rig cooling techniques. As the window of observable behavior is expanded, and as the technology matures toward eventual integration within gas turbines, monitoring techniques must evolve to better match industrial diagnostics. High-speed image analysis techniques prove useful to capture and evaluate the unsteady detonation behavior within the RDE. Traditional image analysis techniques, however, require extensive processing times which prohibit simultaneous monitoring. To better address this problem, a computer vision object detection methodology is proposed to quickly detect individual detonation waves within a single down-axis image. Detonation waves are detected in individual images by the implemented computer vision method You Only Look Once (YOLO) object detection network. In order to detect detonation waves, the network must first be trained using RDE images of interest, for which each required phase of network development is outlined. Detection of waves is improved through proper treatment of the collected image set, variation of Intersection over Union (IoU) and confidence thresholding, and through a parametric study of annotation dimensions. Each detected wave is described by its location and rotational direction, and locations are tracked to calculate wave velocity across each frame, leading to a timestep resolution of 20 µs. Wave velocities are also calculated through a series of frames, leading to a suitable average velocity estimation using as few as 10 frames. Uncertainty analysis accounting for variation in camera framerate, pixel width and annotation centroid locations estimates a total uncertainty of ±4.3% for velocity calculations, using the smallest annotation boxes. This method offers great reductions in processing times, as a step toward real-time monitoring of detonation waves within an RDE. Improving on previous studies, this technique is impartial to wave modes not included in the original training set and calculates wave velocities independent of high-speed pressure data. The ability to isolate waves within predicted bounding boxes will likely facilitate analysis of pixel intensity variation as an estimation of wave strength in future work.

Johnson, Kristyn↗

Review of Pantex Radiation Safety Department 2020 Backup Dosimetry Processing Methodology

In the first quarter (Q1) of Calendar Year 2020, the Pantex Radiation Safety Department (Pantex) experienced various issues and failures with their dosimeter processing equipment. Efforts to repair the equipment resulted in limited functionality without the ability to process dosimeters assigned to personnel for monitoring dose. As a result of the impairments to the dosimeter processing equipment, Pantex called upon Nevada National Security Site (NNSS) for support, as their designated backup processor. In January of 2021, LLNL Subject Matter Experts in External Dosimetry started an NNSA-requested review of Pantex’s personnel doses in Q1 2020. Its focus was the technical validity of the means and methods used by Pantex and its conclusions and provide a level of confidence to National Nuclear Security Administration (NNSA) that the resulting personnel doses were reasonable, conservative, and defensible.

61 RADIATION PROTECTION AND DOSIMETRY↗

AUTOMATED LEAK DETECTION OF BURIED TANKS USING GEOPHYSICAL METHODS AT THE HANFORD NUCLEAR SITE

At the Hanford Nuclear Site in Washington State, the Department of Energy oversees the containment, treatment, and retrieval of liquid high-level radioactive waste. Much of the waste is stored in single-shelled tanks (SSTs) built between 1943 and 1964. Currently, the waste is being retrieved from the SSTs and transferred into newer double-shelled tanks (DSTs) for temporary storage before final treatment. Monitoring the tanks during the retrieval process is critical to identifying leaks. An electrically-based geophysics monitoring program for leak detection and monitoring (LDM) has been successfully deployed on several SSTs at the Hanford site since 2004. The monitoring program takes advantage of changes in contact resistance that will occur when conductive tank liquid leaks into the soil. During monitoring, electrical current is transmitted on a number of different electrode types (e.g., steel cased wells and surface electrodes) while voltages are measured on all other electrodes, including the tanks. Data acquisition hardware and software allow for continuous real-time monitoring of the received voltages and the leak assessment is conducted through a time-series data analysis. The specific hardware and software combination creates a highly sensitive method of leak detection, complementing existing drywell logging as a means to detect and quantify leaks. Working in an industrial environment such as the Hanford site presents many challenges for electrical monitoring: cathodic protection, grounded electrical infrastructure, lightning strikes, diurnal and seasonal temperature trends, and precipitation, all of which create a complex environment for leak detection. In this discussion we present examples of challenges and solutions to working in the tank farms of the Hanford site.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Identification of Natural Oscillation Modes for Purposes of Seismic Assessment and Monitoring of HPP Dams

The paper puts forward a method for processing data from detailed seismic assessments of HPP dams (dynamic tests). A detailed assessment (hundreds of observation points in dam galleries) is performed with consideration of operating dam equipment and the microseismic noise. It is shown that dynamic oscillation characteristics (natural oscillation frequencies and modes in the main dam axes, the velocities of propagation of elastic waves with given polarization, and so on.) can be determined with sufficient accuracy by using complex transfer functions and pulse characteristics. Monitoring data is processed using data from a detailed assessment, taking account of identified natural oscillation modes and determined ranges of natural frequencies. The spectra of characteristic frequencies thus obtained are used to choose substitution models and estimate the elastic characteristics of the “dam – rock bed” construction system, viz., the modulus of elasticity (the Young modulus), the Poisson ratio, the dam section stiffness with respect to shear, tension and compression and the elastic characteristics of the rock foundation.

42 ENGINEERING↗

Condition monitoring and false alarm reducing of sensors in NPP - 222

With more and more application of digital I and C systems in nuclear power plants (NPP), more and more sensors are also required. Large amount of sensors really can make contribution to the condition monitoring of systems and equipment in NPP, whereas the heavy use also increases the malfunction risk of sensor self. Therefore the reliability and effectiveness of sensors must be guaranteed first. Thus the condition of sensors should be monitored first in a NPP. Since the precise mathematical models of sensors in complex systems are relative difficult to establish, however quantity of operating data can be easily obtained due to the wide application of digital I and C systems, thus this article adopts principal component analysis (PCA) to carry out condition monitoring for sensors. The PCA model developed for sensors is proved to be effective with operating data acquired from a real NPP. It can detect and isolate the fault when an artificial fault is imposed to the normal data. Then the monitoring results are further processed by another control limit (second confidence limit) besides T 2 and Q statistics (first confidence limit) in PCA. The value of second confidence limit is calculated based on the probability statistics of T 2 and Q statistics. And simulation tests show that the application of the second confidence limit can greatly reduce false alarms in the PCA model and the model performance can be greatly improved with the application of false alarms reducing method. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Low-coherence interferometry as a tool for monitoring laser micro- and nanoprocessing of diamond surfaces

We have demonstrated the possibility of using low-coherence tandem optical interferometry for monitoring the local laser processing of diamond surfaces. Noncontact measurements of the optical thickness of single-crystal diamond plates were performed directly during the exposure of the surface to repetitive intense laser pulses. We investigated the dynamics of the thinning of a single crystal in two radically different regimes of laser etching: ablation (KrF excimer laser, λ = 248 nm, τ = 20 ns) and nanoablation (Ti : sapphire laser, λ = 266 nm, τ = 100 fs). (laser technologies)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Region-based convolutional neural network for wind turbine wake characterization from scanning lidars

A convolutional neural network is applied to lidar scan images from three experimental campaigns to identify and characterize wind turbine wakes. Initially developed as a proof-of-concept model and applied to a single data set in complex terrain, the model is now improved and generalized and applied to two other unique lidar data sets, one located near an escarpment and one located offshore. The model, initially developed using lidar scans collected in predominantly westerly flow, exhibits sensitivity to wind flow direction. The model is thus successfully generalized through implementing a standard rotation process to scan images before input into the convolutional neural network to ensure the flow is westerly. The sample size of lidar scans used to train the model is increased, and along with the generalization process, these changes to the model are shown to enhance accuracy and robustness when characterizing dissipating and asymmetric wakes. Applied to the offshore data set in which nearly 20 wind turbine wakes are included per scan, the improved model exhibits a 95% success rate in characterizing wakes and a 74% success rate in characterizing dissipating wake fragments. The improved model is shown to generalize well to the two new data sets, although an increase in wake characterization accuracy is offset by an increase in model sensitivity and false positive wake identifications.

17 WIND ENERGY↗

Multi-Target Camera Tracking, Hand-off and Display LDRD 158819 Final Report

Modern security control rooms gather video and sensor feeds from tens to hundreds of cameras. Advanced camera analytics can detect motion from individual video streams and convert unexpected motion into alarms, but the interpretation of these alarms depends heavily upon human operators. Unfortunately, these operators can be overwhelmed when a large number of events happen simultaneously, or lulled into complacency due to frequent false alarms. This LDRD project has focused on improving video surveillance-based security systems by changing the fundamental focus from the cameras to the targets being tracked. If properly integrated, more cameras shouldn’t lead to more alarms, more monitors, more operators, and increased response latency but instead should lead to better information and more rapid response times. For the course of the LDRD we have been developing algorithms that take live video imagery from multiple video cameras, identify individual moving targets from the background imagery, and then display the results in a single 3D interactive video. In this document we summarize the work in developing this multi-camera, multi-target system, including lessons learned, tools developed, technologies explored, and a description of current capability.

47 OTHER INSTRUMENTATION↗

A Multimodal Event Catalog and Waveform Data Set That Supports Explosion Monitoring from Nevada, U.S.A.

Multimodal, curated data sets and nuisance event catalogs remain rare in the explosion monitoring community relative to curated seismic data sets. The source of this relative absence is the difficultly in deploying multimodal receivers that sense the seismic, acoustic, and other modalities from multiphysics sources. We provide such a data set in this study that delivers seismic, infrasound, and electromagnetic (magnetometer) sensor records collected over a two–week period, within 255 km of a 10 ton buried chemical explosion called DAG–4 that was located at 37.1146°, –116.0693° on 22 June 2019 21:06:19.88 UTC. This catalog includes 485 seismic, seismoacoustic, and infrasound–only events that an expert analyst manually built by reviewing waveforms from 29 seismic and infrasound sensors. Our data release includes waveforms from these 29 seismic, infrasound, and seismoacoustic stations and two magnetometer stations and their station metadata. We deliver these waveforms in NNSA KB Core CSS.w format (i4) with a corresponding wfdisc table that provides the header information. Here, we expect that this data set will provide a valuable, benchmark resource to develop signal processing algorithms and explosion monitoring methods against manual, human observations.

58 GEOSCIENCES↗

TH-C-18A-08: A Management Tool for CT Dose Monitoring, Analysis, and Protocol Review

Purpose: To develop a customizable tool for enterprise-wide managing of CT protocols and analyzing radiation dose information of CT exams for a variety of quality control applications Methods: All clinical CT protocols implemented on the 11 CT scanners at our institution were extracted in digital format. The original protocols had been preset by our CT management team. A commercial CT dose tracking software (DoseWatch,GE healthcare,WI) was used to collect exam information (exam date, patient age etc.), scanning parameters, and radiation doses for all CT exams. We developed a Matlab-based program (MathWorks,MA) with graphic user interface which allows to analyze the scanning protocols with the actual dose estimates, and compare the data to national (ACR,AAPM) and internal reference values for CT quality control. Results: The CT protocol review portion of our tool allows the user to look up the scanning and image reconstruction parameters of any protocol on any of the installed CT systems among about 120 protocols per scanner. In the dose analysis tool, dose information of all CT exams (from 05/2013 to 02/2014) was stratified on a protocol level, and within a protocol down to series level, i.e. each individual exposure event. This allows numerical and graphical review of dose information of any combination of scanner models, protocols and series. The key functions of the tool include: statistics of CTDI, DLP and SSDE, dose monitoring using user-set CTDI/DLP/SSDE thresholds, look-up of any CT exam dose data, and CT protocol review. Conclusion: our inhouse CT management tool provides radiologists, technologists and administration a first-hand near real-time enterprise-wide knowledge on CT dose levels of different exam types. Medical physicists use this tool to manage CT protocols, compare and optimize dose levels across different scanner models. It provides technologists feedback on CT scanning operation, and knowledge on important dose baselines and thresholds.

60 APPLIED LIFE SCIENCES↗

Quantifying and Qualifying Alloys Based on Level of Homogenization: A U-10Mo Alloy Case Study

Homogenization heat treatment is performed to attain uniformity in microstructure which is helpful to achieve the desired workability and microstructure in final products and, eventually, to gain predictive and consistent performance. Fabrication of low-enriched uranium alloys with 10 wt% molybdenum (U-10Mo) fuel plates involves multiple thermomechanical processing steps. It is well known that the molybdenum homogeneity in the final formed product affects the performance in the nuclear reactor. Here, to ensure uniform homogenization, a statistical method is proposed to quantify and characterize the molybdenum concentration variation in U-10Mo fuel plates by analyzing the molybdenum concentration measurement data from scanning electron microscopy energy dispersive spectroscopy line-scan. Statistical tolerance intervals (TI) are employed to determine the qualification of the U-10Mo fuel plate. We formulate an argument for the minimum number of independent samples to define fuel plate qualification if no molybdenum measurement data are available in advance and demonstrate that the given TI requirements can be equivalently reduced to a sample variance criterion in this application. The outcome of the statistical analysis can be used to optimize casting design and eventually increase productivity and reduce fabrication costs. The statistical strategy developed in this paper can be implemented for other applications especially in the field of material manufacturing to assess qualification requirements and monitor and improve the process design.

36 MATERIALS SCIENCE↗

Portable quantitative confocal Raman spectroscopy: Non-destructive approach of the carbonation chemistry and kinetics

Highlights: • Raman spectroscopy was used to monitor carbonation of portlandite • The approach was non-destructive, continuous, and performed within the material • Carbonation was identified coupling Raman spectroscopy and chemometrics • Kinetics was calculated for one portlandite thickness at different CO{sub 2}-percentages Carbonation is one major alteration process of cementitious materials. It can be monitored through several methods, all destructive. In this study, some preliminary investigations were conducted to monitor the carbonation process of pure portlandite with an in situ and non-destructive spectroscopic method. This complementary approach was motivated by a literature review indicating the benefits of Raman spectroscopy, but requiring innovative approaches for data acquisition and analysis. The material was selected to validate this spectroscopic monitoring, coupled with chemometrics tools to allowing an early detection of the carbonation reaction through a structure identified in the spectra data population. The carbonation occurred abruptly, and spectra analysis indicated the occurrence of phases synonymous of microstructural evolutions. Varying the atmospheric percentage of CO{sub 2} (0.04% - 4%) conducted to an appreciation of the kinetics of the carbonation front through the same thickness of portlandite.

36 MATERIALS SCIENCE↗

Structure of Asphaltenes during Precipitation Investigated by Ultra-Small-Angle X-ray Scattering

Time-resolved size and structure measurements of asphaltenes while in the process of precipitating were monitored for the first time using ultra-small-angle X-ray scattering. The results revealed that asphaltenes precipitating from a heptane–toluene mixture demonstrate a hierarchical structure of an asphaltene-rich phase (e.g., droplet) that further agglomerates into fractal flocs. The fractal flocs that form by the agglomeration of the asphaltene-rich phase are what is commonly detected by optical microscopy above the precipitation detection point. The surface of the asphaltene-rich phase is initially rough and transitions to a smooth interface, as would be expected for a highly viscous liquid. Simultaneous small-angle X-ray scattering measurements were also performed to investigate the structure of soluble asphaltenes, providing comprehensive structural characterization from the nanometer- to micrometer-length scales as a function of time. Further, the results demonstrate that the size and concentration of asphaltenes remaining in solution (e.g., soluble asphaltenes) do not change during precipitation, whereas the structure of insoluble asphaltenes varies. The ability to measure the properties of asphaltenes as they undergo precipitation opens new opportunities for understanding the fundamental mechanisms of asphaltene deposition and aggregation and the impact of chemical inhibitors to alter these processes. Here, the universality of these conclusions and how specific properties vary as a function of asphaltene source and solution properties can provide valuable insight into asphaltene behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗