Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse Power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Magneto-Hydrodynamic Modeling in the Design and Interpretation of Wire Array Z-pinches

Magneto-hydrodynamic simulations provide a powerful tool for improving our understanding of the complex physical processes underlying the behavior of wire array Z-pinches. We show how, by using large scale parallel 3D simulations of the array as a whole, it is possible to encompass all of the important features of the wire ablation, implosion and stagnation phases and to observe how these phenomena control the X-ray pulse that is achieved. Comparison of code results with experimental data from the 'Z' and MAGPIE pulsed power generators is shown to provide a detailed benchmark test for the models. The simulation results are also used to highlight key areas for future research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental study of self magnetic pinch diode as flash radiography source at 4 megavolt

The Self Magnetic Pinch (SMP) diode is a potential high-brightness X-ray source for high voltage generators (2–10 MV) that has shown good reliability for flash radiography applications [D. D. Hinchelwood et al., “High power self-pinch diode experiments for radiographic applications” IEEE Trans. Plasma Sci. 35(3), 565–572 (2007)]. We have studied this diode at about 4 MV, driven by the ASTERIX generator operated at the CEA/GRAMAT [G. Raboisson et al., “ASTERIX, a high intensity X-ray generator,” in Proceedings of the 7th IEEE Pulsed Power Conference (1989), pp. 567–570]. This generator, made up of a capacitor bank and a Blumlein line, was initially designed to test the behavior of electronic devices under irradiation. In our experiments, the vacuum diode is modified in order to set up flash radiographic diodes. A previous set of radiographic experiments was carried out on ASTERIX with a Negative Polarity Rod Pinch (NPRP) diode [B. Etchessahar et al., “Study and optimization of negative polarity rod pinch diode as flash radiography source at 4.5 MV,” Phys. Plasmas 19(9), 093104 (2012)]. The SMP diode which is examined in the present study provides an alternative operating point on the same generator and a different radiographic performance: 142 ± 11 rad at 1 m dose (Al) for a 3.46 ± 0.42 mm spot size (1.4× FWHM of the LSF). This performance is obtained in a reproducible and robust nominal configuration. However, several parametric variations were also tested, such as cathode diameter and anode/cathode gap. They showed that an even better performance is accessible after optimization, in particular, a smaller spot size (<3 mm). Numbers of electrical, optical, and X-ray diagnostics have been implemented in order to gain more insight in the diode physics and to optimize it further. For the first time in France, visible and laser imaging of the SMP diode has been realized, from a radial point of view, thus, providing key information on the electrode plasmas evolution, responsible for the gap closure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Super-Compact Laser

Microcosm, Inc. produced the portable Farfield-2 laser for field applications that require high power pulsed illumination. The compact design was conceived through research at Goddard Space Flight Center on laser instruments for space missions to carry out geoscience studies of Earth. An exclusive license to the key NASA patent for the compact laser design was assigned to Microcosm. The FarField-2 is ideal for field applications, has low power consumption, does not need water cooling or gas supplies, and produces nearly ideal beam quality. The properties of the laser also make it effective over long distances, which is one reason why NASA developed the technology for laser altimeters that can be toted aboard spacecraft. Applications for the FarField-2 include medicine, biology, and materials science and processing, as well as diamond marking, semiconductor line-cutting, chromosome surgery, and fluorescence microscopy.

Source record↗

Investigations into Cost Reductions of X-band Instrumentation

The prohibitive costs of commercial test equipment for making fast and accurate pulsed phase and amplitude measurements at X-Band result in decreased productivity due to shortages of shared equipment across the test laboratory. In addition, most current set-ups rely on the use of pulsed power heads which do not allow for the measurement of phase thereby limiting the flexibility of available measurements. In this paper, we investigate less expensive in-house designed instrumentation based upon commercial satellite down converters and widely available logarithmic detector amplifiers and phase detectors. The techniques are used to measure X-Band pulses with widths of 50 ns to 10's of usec. We expect a dynamic range of 30-40 dB with accuracies of better than +/- 0.1 dB and +/- 1 degree of phase. We show preliminary results of the built and tested modules. Block diagrams of the down conversion scheme, and the architecture of a multi-signal X-band RF monitor and measurement system is illustrated. Measured results, and possible modifications and upgrades are presented.

43 PARTICLE ACCELERATORS↗

Ultralightweight Power System for Human-Portable Linac-Based X-Ray Sources

Industrial human-portable X-ray sources are widely used by security, nuclear safeguard, and defense agencies. However, the employed sources have significant energy, dose, size, weight, and power (SWaP) limitations, greatly affecting their practical application. RF linear accelerators (linacs) can serve as a flexible, reliable, and robust type of X-ray source if they can match the size, weight, cost, and imaging performance requirements of conventional ones. One of the most critical elements affecting these parameters is the high-voltage pulsed power supply system or modulator, which can make the largest contribution to the total weight and dimensions of the accelerator. Here, in this article, we present the design and demonstration results of a novel ultra lightweight power system based on a 24-kV solid-state Marx modulator for a hand-portable 0.15–2.0-MeV Ku -band linac-based X-ray source.

47 OTHER INSTRUMENTATION↗

Laser Energy Monitor for Triple-Pulse 2-μm IPDA Lidar Application

Integrated path differential absorption (IPDA) lidar is an active remote sensing technique for monitoring different atmospheric species. The technique relies on wavelength differentiation between strong and weak absorbing features normalized to the transmitted energy. An advanced 2-μm triple-pulse IPDA lidar was developed at NASA Langley Research Center for active sensing of carbon dioxide and water vapor simultaneously. The IPDA transmitter produces three successive laser pulses separated by a short interval (200 μs) with a repetition rate of 50Hz. Measurement of laser pulse energy accurately is a prerequisite for the retrieval of gas mixing ratios from IPDA. The design and calibration of a 2-μm triple-pulse laser energy monitor are presented. Due to the short interval between the three transmitted pulses, conventional thermal energy monitors underestimate the total transmitted energy. The design is based on a high speed, extended range InGaAs pin quantum detector suitable for separating the three pulse events. Pulse integration is applied for converting the detected pulse power into energy. The results obtained from the laser energy monitor were compared to an ultra-fast energy-meter reference for energy scaling and verification. High correlations between the pin energy monitor and the total transmitted energy were obtained. The objective of this development is to reduce measurement biases and errors using the triple-pulse IPDA technique.

Refaat, Tamer F.↗

Neutronics and Transient Calculations for the Conversion of the Transient Reactor Rest Facility (TREAT)

The Transient Reactor Test Facility (TREAT) is a graphite-reflected, graphitemoderated, and air-cooled reactor fueled with 93.1% enriched UO2 particles dispersed in graphite, with a carbon-to-235U ratio of ~10000:1. TREAT was used to simulate accident conditions by subjecting fuel test samples placed at the center of the core to high energy transient pulses. The transient pulse production is based on the core’s selflimiting nature due to the negative reactivity feedback provided by the fuel graphite as the core temperature rises. The analysis of the conversion of TREAT to low enriched uranium (LEU) is currently underway. This paper presents the analytical methods used to calculate the transient performance of TREAT in terms of power pulse production and resulting peak core temperatures. The validation of the HEU neutronics TREAT model, the calculation of the temperature distribution and the temperature reactivity feedback as well as the number of fissions generated inside fuel test samples are discussed.

Kontogeorgakos, Dimitrios C.↗

Effect of an Energy Reservoir on the Atmospheric Propagation of Laser-Plasma Filaments

The ability to select and stabilize a single filament during propagation of an ultrashort, high-intensity laser pulse in air makes it possible to examine the longitudinal structure of the plasma channel left in its wake. We present the first detailed measurements and numerical 3-D simulations of the longitudinal plasma density variation in a laser-plasma filament after it passes through an iris that blocks the surrounding energy reservoir. Since no compensation is available from the surrounding background energy, filament propagation is terminated after a few centimeters. For this experiment, simulations indicate that filament propagation is terminated by plasma defocusing and ionization loss, which reduces the pulse power below the effective self-focusing power. With no blockage, a plasma filament length of over a few meters was observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theory and simulations of electron vortices generated by magnetic pushing

Vortex formation and propagation are observed in kinetic particle-in-cell (PIC) simulations of magnetic pushing in the plasma opening switch. These vortices are studied here within the electron-magnetohydrodynamic (EMHD) approximation using detailed analytical modeling. PIC simulations of these vortices have also been performed. Strong v×B forces in the vortices give rise to significant charge separation, which necessitates the use of the EMHD approximation in which ions are fixed and the electrons are treated as a fluid. A semi-analytic model of the vortex structure is derived, and then used as an initial condition for PIC simulations. Density-gradient-dependent vortex propagation is then examined using a series of PIC simulations. It is found that the vortex propagation speed is proportional to the Hall speed v{sub Hall}≡cB{sub 0}/4πn{sub e}eL{sub n}. When ions are allowed to move, PIC simulations show that the electric field in the vortex can accelerate plasma ions, which leads to dissipation of the vortex. This electric field contributes to the separation of ion species that has been observed to occur in pulsed-power experiments with a plasma-opening switch.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environment

The Z machine is a current driver producing up to 30 MA in 100 ns that utilizes a wide range of diagnostics to assess accelerator performance and target behavior conduct experiments that use the Z target as a source of radiation or high pressures. Here, we review the existing suite of diagnostic systems, including their locations and primary configurations. The diagnostics are grouped in the following categories: pulsed power diagnostics, x-ray power and energy, x-ray spectroscopy, x-ray imaging (including backlighting, power flow, and velocimetry), and nuclear detectors (including neutron activation). We will also briefly summarize the primary imaging detectors we use at Z: image plates, x-ray and visible film, microchannel plates, and the ultrafast x-ray imager. The Z shot produces a harsh environment that interferes with diagnostic operation and data retrieval. We term these detrimental processes “threats” of which only partial quantifications and precise sources are known. Finally, we summarize the threats and describe techniques utilized in many of the systems to reduce noise and backgrounds.

47 OTHER INSTRUMENTATION↗

Fielding the magnetically applied pressure-shear technique on the Z accelerator (completion report for MRT 4519).

The recently developed Magnetically Applied Pressure-Shear (MAPS) experimental technique to measure material shear strength at high pressures on magneto-hydrodynamic (MHD) drive pulsed power platforms was fielded on August 16, 2013 on shot Z2544 utilizing hardware set A0283A. Several technical and engineering challenges were overcome in the process leading to the attempt to measure the dynamic strength of NNSA Ta at 50 GPa. The MAPS technique relies on the ability to apply an external magnetic field properly aligned and time correlated with the MHD pulse. The load design had to be modified to accommodate the external field coils and additional support was required to manage stresses from the pulsed magnets. Further, this represents the first time transverse velocity interferometry has been applied to diagnose a shot at Z. All subsystems performed well with only minor issues related to the new feed design which can be easily addressed by modifying the current pulse shape. Despite the success of each new component, the experiment failed to measure strength in the samples due to spallation failure, most likely in the diamond anvils. To address this issue, hydrocode simulations are being used to evaluate a modified design using LiF windows to minimize tension in the diamond and prevent spall. Another option to eliminate the diamond material from the experiment is also being investigated.

Alexander, C. Scott↗

TREAT HODOSCOPE – A Predictive Simulation Model

The Transient Reactor Test Facility (TREAT) reactor is being restarted after over two decades of standby operation. TREAT is designed to test the time-dependent behavior of nuclear fuel during simulated reactor accidents. One of the principle data collection systems of TREAT is the fast neutron hodoscope which is used to observe the motion of the fuel test specimen as it is being damaged, deformed, or melted over the course of the power transient. The hodoscope is a grid of ex-core collimator channels paired with a bank of fast neutron sensitive radiation detectors. These detectors have historically been calibrated using empirical methods utilizing measurement data from smaller power pulses. Given modern computational capabilities this work sets out to establish a predictive computational capability of the fast neutron flux field exiting the hodoscope to support these calibrations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Efficient general method for numerically modeling laser pulse propagation, overlap, and lifetime effects in amplifiers

An efficient numerical time-dependent general method is developed to address incoherent pulse overlap and lifetime effects in laser amplifiers. The alternating propagation-population laser energetics method (APPLE) has been validated against a semi-discrete coupled rate equation numerical method (SDRE) and analytic formalisms in bounding cases. APPLE is based on decoupled rates applied to a time-dependent framework where both space-time-dependent populations and pulse energetics are consistently updated in each time step. A significant advantage of APPLE lies in its conceptual simplicity, ease of implementation, and relatively small computational cost. SDRE tracks the populations through coupled rates and uses the method of lines to discretize the hyperbolic partial differential transport equations allowing for use of ordinary differential equation solvers. With reasonably sized mesh, we report both energetic and power pulse shape relative differences on the order of one percent between the models over a large range of initial conditions.

47 OTHER INSTRUMENTATION↗

An 8-{mu}m quantum cascade laserproduced by the metalorganic vapour phase epitaxy method

An 8-{mu}m quantum cascade laser is fabricated by the metalorganic vapour phase epitaxy method. A scheme of vertical transitions in a structure consisting of three quantum wells is used. The laser operates in a pulsed regime at temperatures up to 250 K. The threshold current density was about 3 kA cm{sup -2} and increased up to 6 kA cm{sup -2} at 250 K. The 1-{mu}s pulse power in the multimode regime was 45 mW at 77 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sources of Primary Electrons in Nanosecond Pulsed Breakdown in Water (Final Technical Report)

Electrical breakdown of liquid dielectrics under ns or sub-ns pulsed electric field has been studied extensively in the last decade. Summarized in [7], this relatively young research area makes significant contributions to the theories of liquid breakdown by introducing a new mechanism (electrostrictive cavitation) that is unique at the ns timescale. It is also fundamentally important to plasma sources for biomedical applications and insulation of pulsed power equipment. For water in particular, the understanding of the mechanisms and processes of ns/sub-ns breakdown also sheds new light on cavitation studies, one of the most exciting areas of modern fluid mechanics. The objective of this collaborative research with PCRF was to construct a complete picture of the physical mechanisms and processes at the initial phase of electrical breakdown in liquid dielectrics under nanosecond (ns) pulsed inhomogeneous fields. The research funded by the initial award DE‐ SC0021182 aimed to address the sources of primary electrons in ns breakdown in water, which led to one journal publication and multiple conference presentations. The PI also gave presentations to the PPPL/PCRF audience twice, one in October 2020 and the other during the 2021 PCRF Annual Meeting

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synchrotron characterization of high-Z, current-mode x-ray detectors

Fast x-ray detectors are critical tools in pulsed power and fusion applications, where detector impulse response of a nanosecond or better is often required. Semiconductor detectors can create fast, sensitive devices with extensive operational flexibility. There is typically a trade-off between detector sensitivity and speed, but higher atomic number absorbers can increase hard x-ray absorption without increasing the charge collection time, provided carriers achieve high velocity. This paper presents x-ray pulse characterization conducted at the Advanced Photon Source of x-ray absorption efficiency and temporal impulse response of current-mode semiconductor x-ray detectors composed of Si, GaAs, and CdTe.

47 OTHER INSTRUMENTATION↗

X-ray intensity and source size characterizations for the 25 kV upgraded Manson source at Sandia National Laboratories

At Sandia National Laboratories, the x-ray generator Manson source model 5 was upgraded from 10 to 25 kV. The purpose of the upgrade is to drive higher characteristics photon energies with higher throughput. In this work we present characterization studies for the source size and the x-ray intensity when varying the source voltage for a series of K-, L-, and M-shell lines emitted from Al, Y, and Au elements composing the anode. We used a 2-pinhole camera to measure the source size and an energy dispersive detector to monitor the spectral content and intensity of the x-ray source. As the voltage increases, the source size is significantly reduced and line intensity is increased for the three materials. We can take advantage of the smaller source size and higher source throughput to effectively calibrate the suite of Z Pulsed Power Facility crystal spectrometers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Research and development of RHIC injection kicker upgrade with nano second FID pulse generator

Our recent effort to test a 50 kV, 1 kA, 50 ns pulse width, 10 ns pulse rise time FID pulse generator with a 250 ft transmission cable, resistive load, and existing RHIC injection kicker magnet has produced unparalleled results. This is the very first attempt to drive a high strength fast kicker magnet with a nano second high pulsed power (50 MVA) generator for large accelerator and colliders. The technology is impressive. We report here the result and future plan of RHIC Injection kicker upgrade.

43 PARTICLE ACCELERATORS↗