Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reference Model 5”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Data from: "Warming and the dependence of limber pine (Pinus flexilis) establishment on summer soil moisture within and above its current elevation range"

This data package contains data that were used for analysis in “Warming and the dependence of limber pine (Pinus flexilis) establishment on summer soil moisture within and above its current elevation range”, by Moyes et al. 2013. All data collection and field research were completed on Niwot Ridge, Colorado, USA.This data package contains nine comma-separated-values (.csv) files, one text (.txt) file, and two zipped seedling folders that were used for leaf area analysis. One zipped folder contains 468 .jpg photographs of seedlings, and the second contains 468 corresponding Image J-processed .jpg images that include silhouette leaf area values. .csv and .txt files can be opened using any compatible simple text-editor software such as TextEdit (Mac) and Notepad (Windows); .csv’s can also be opened using R and Microsoft Excel. Image files can be opened using Preview (Mac) and Photos (Windows). In addition, there are a total of 31 Microsoft Excel files: three .xlsx files, and 28 raw Li-Cor output .xls files. This data user’s guide is available in .pdf format, and can be opened using Adobe Acrobat Reader, or any other compatible file viewing software. Geospatial data showing field site locations are also included in the archive for use and reference. There are two geospatial formats in this archive: ESRI shapefiles (.shp) and keyhole markup-language (.kml) files. Both file types contain bounding box information, with the former being polygons, and the latter containing corner coordinates for each site. ESRI shapefiles can be opened using any geospatial software compatible with the file type (such as ESRI’s ArcGIS suite and QGIS), and .kml files are compatible with Google Earth and Google Maps.--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Continued changes in climate are projected to alter the geographic distributions of plant species, in part by affecting where individuals can establish from seed. We tested the hypothesis that warming promotes uphill redistribution of subalpine tree populations by reducing cold limitation at high elevation and enhancing drought stress at low elevation. We seeded limber pine (Pinus flexilis) into plots with combinations of infrared heating and water addition treatments, at sites positioned in lower subalpine forest, the treeline ecotone, and alpine tundra. In 2010, first-year seedlings were assessed for physiological performance and survival over the snow-free growing season. Seedlings emerged in midsummer, about 5–8 weeks after snowmelt. Low temperature was not observed to limit seedling photosynthesis or respiration between emergence and October, and thus experimental warming did not appear to reduce cold limitation at high elevation. Instead, gas exchange and water potential from all sites indicated a prevailing effect of summer moisture stress on photosynthesis and carbon balance. Infrared heaters raised soil growing degree days (base 5 °C, p < 0.001) and August–September mean soil temperature (p < 0.001). Despite marked differences in vegetation cover and meteorological conditions across sites, volumetric soil moisture content (θ) at 5–10 cm below 0.16 and 0.08 m^3 m^(−3) consistently corresponded with moderate and severe indications of drought stress in midday stem water potential, stomatal conductance, photosynthesis, and respiration. Seedling survival was greater in watered plots than in heated plots (p = 0.01), and negatively related to soil growing degree days and duration of exposure to θ < 0.08 m^3 m^(−3) in a stepwise linear regression model (p < 0.0001). We concluded that seasonal moisture stress and high soil surface temperature imposed a strong limitation to limber pine seedling establishment across a broad elevation gradient, including at treeline, and that these limitations are likely to be enhanced by further climate warming.--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Maintenance log:Amended file name error in Data User's Guide May 19 2022

54 ENVIRONMENTAL SCIENCES↗

Scalar Atomic Defect-Based Solid-State Self-calibrating Magnetometer (3SM) for Space Plasma Analysis

The Earth’s magnetosphere is a system of multiple, co-located particle populations interacting via plasma waves. Things to understand are driving processes, radiation belt and ring current issues, auroral physics, internal plasma processes, and magnetosphere-ionosphere mapping issues. These plasma-physics processes enable the Earth’s magnetosphere to evolve in response to temporal changes in the solar wind and they underlie the phenomena of space weather, which impacts spacecraft systems, astronauts, radio communications, and ground based electric-power grids. The objective of 3SM is to measure magnetic field strength and to calibrate the Vector Magnetometer (VM) device to maintain absolute accuracy during a mission. The 3SM features make the instrument preferably suited not only for the traditional role of scalar magnetometers as absolute references for the calibration of the on-board vector instruments, but also for extended operational capacities, such as higher frequency scalar measurements (of potential interest for magnetosphere studies for the low frequency part of the spectrum) or autonomous scalar / vector operations. Diamond has been the solid-state platform of choice for quantum device technologies for some time, however, it suffers from difficulties such as scalability, integration, and cost. While the diamond platform is very useful for quantum technologies, further development is needed to make it viable. The material platform of choice for NASA Glenn’s Quantum Sensing And Spin Physics (Q-SASP) is silicon carbide (SiC). This is due to the much higher industry development of the SiC material platform for high-power and high-temperature electronics. It leverages both the decades-long SiC development expertise and infrastructure at NASA Glenn and its growing capabilities in quantum metrology. To make SiC devices usable for quantum technologies such as quantum sources, a much deeper understanding of defects is needed. Q-SASP is developing quantum metrology capabilities to evaluate the energy structure, defect formation energy, band structure augmentation, generation/recombination rates, and limits of dipole-dipole coupling in non-metal implanted SiC devices. This can be achieved by analysis of zero-field splitting, low-field resonance, and singlet-triplet mixing through various forms of Electrically Detectable Magnetic Resonance (EDMR) and Near-Zero Field Magnetic Resonance (NZFMR) spectroscopy. This work will discuss recent system developments, device developments, computational modeling, and spectroscopy results and analysis of defects created by non-metal implantations in SiC devices. The defect formation energies of V Si ,V C , V C V Si , N C V Si , N Si , N C in 4H-SiC are previously reported values in other research [2]-[3]. The defect formation energies of PSi and PC were calculated in GPAW [fig 1A]. The basic underlying mechanism of the zero-field phenomenon is the mixing of singlet and triplet states [4]-[5]. In most spin-dependent transport, two electron spins are involved, and thus one must consider each of their interactions with the field. We investigated the electronic and magnetic properties of 4H-SiC and 6H-SiC. The defect formation energy helps us determine what types of defects we are observing in the SiC EDMR experiment. They have very low formation energy (it is negative). The phosphorus substitution in 4H-SiC is a very stable defect. The band diagrams provide us with vital information about how the electronic properties of SiC (such as band gap) change as we add non-metal defects. The zero-field splitting parameters allow us to study the inflection point in the NZFMR [fig 1B]. We clearly observed zero-field splitting. We also noted that the zero-field splitting remained constant with changing bias. We aspect it zero-field splitting to remain constant while the hyperfine and exchange interaction perturbations shift under the influence of an external magnetic field. This is the essence of quantum magnetometry and self-calibration.

space plasma↗

Atomic-scale Imaging of PGM-free Catalyst Active Sites by 30 keV 4D-STEM

Platinum group metal (PGM)-free catalysts have attracted a large amount of attention due to their potential for enabling low-cost, commercially viable hydrogen fuel cells and electrolyzers [1]. Degradation of cell performance remains a significant challenge, however, currently limiting implementation of devices that utilize PGM-free materials [2]. Controlling degradation in these materials requires a better understanding of the atomic structure of active sites, thought to be FeN4 structures within a graphitic carbon lattice, which would enable more accurate prediction of the associated degradation pathways. The exact structural arrangement of active sites in these materials is still debated since a range of structures have been computationally predicted and methods to directly validate these models are still needed [1,3-5].While scanning transmission electron microscopy (STEM) has provided initial glimpses into the nature of the proposed active sites, detailed evaluation of the structure of these sites is challenging since they involve defects, edges, and nitrogen dopants in the graphitic lattice, which are susceptible to beam damage [6,7]. Conventional STEM imaging and spectroscopy methods exacerbate this problem with dose-inefficiency or nonideal contrast characteristics for imaging light and heavy elements simultaneously. A method that minimizes damage while generating dose-efficient, easily-interpretable contrast for both light and heavy elements is therefore needed to facilitate imaging of sensitive active site atomic structure.Here, we demonstrate direct atomic-scale imaging of PGM-free catalyst active sites by low-voltage four-dimensional (4D)-STEM. To accomplish this, we pair a 30 keV aberration-corrected probe, which minimizes knock-on damage, with a fast pixelated detector that has optimal performance at low beam energies [8]. We show how this setup enables relatively simple center-of-mass (CoM) techniques [9,10] to produce images with an increased signal-to-noise ratio (SNR) and light-element contrast over conventional imaging modes, allowing the entire active site structure to be imaged at the atomic scale. Moreover, we show how electron ptychography [11,12] enables images with further improved characteristics to be obtained, for example by minimizing residual aberrations, which provides a more accurate structural representation. The increased understanding that these low-voltage 4D-STEM techniques will provide about the atomic structure of PGM-free active sites and their associated degradation pathways will facilitate rational design of next-generation materials, promoting development of low-cost hydrogen fuel cells, electrolyzers, and other energy conversion devices [13]. References:[1] U Martinez et al., Adv. Mater. 31 (2019), p. 1806545.[2] Y Shao et al., Adv. Mater. 31 (2019), p. 1807615.[3] J Kneebone et al., J. Phys. Chem. C 121, (2017), p.16283.[4] T Mineva et al., ACS Catal. 9 (2019), p. 9359.[5] J Li et al., Nat. Catal. 4 (2021), p. 10.[6] T Susi et al., ACS Nano 6 (2012), p. 8837.[7] P Zelenay and DJ Myers, US Department of Energy Hydrogen and Fuel Cells Program 2017 Annual Merit Review and Peer Evaluation Meeting, Washington, DC (2017).[8] H Ryll et al., J. Inst. 11 (2016), p. P04006.[9] K Müller et al., Nat. Commun. 5 (2014), p. 5653.[10] I Lazic et al., Ultramicroscopy 160 (2016), p. 265.[11] H Yang et al., Nat. Commun. 7 (2016), p. 12532.[12] Y Jiang et al., Nature 559 (2018), p. 343. [13] Research sponsored by the Hydrogen and Fuel Cell Technologies Office, Office of Energy Efficiency and Renewable Energy, US Department of Energy (DOE). Research was conducted at the Center for Nanophase Materials Sciences, which is a DOE Office of Science User Facility.

Zachman, Michael↗

Global Summary MGS TES Data and Mars-Gram Validation

Mars Global Reference Atmospheric Model (Mars-GRAM 2001) is an engineering-level Mars atmosphere model widely used for many Mars mission applications. From 0-80 km, it is based on NASA Ames Mars General Circulation Model (MGCM), while above 80 km it is based on University of Arizona Mars Thermospheric General Circulation Model. Mars-GRAM 2001 and MGCM use surface topograph$ from Mars Global Surveyor Mars Orbiting Laser Altimeter (MOLA). Validation studies are described comparing Mars-GRAM with a global summary data set of Mars Global Surveyor Thermal Emission Spectrometer (TES) data. TES averages and standard deviations were assembled from binned TES data which covered surface to approx. 40 km, over more than a full Mars year (February, 1999 - June, 2001, just before start of a Mars global dust storm). TES data were binned in 10-by-10 degree latitude-longitude bins (i.e. 36 longitude bins by 19 latitude bins), 12 seasonal bins (based on 30 degree increments of Ls angle). Bin averages and standard deviations were assembled at 23 data levels (temperature at 21 pressure levels, plus surface temperature and surface pressure). Two time-of day bins were used: local time near 2 or 14 hours local time). Two dust optical depth bins wereused: infrared optical depth either less than or greater than 0.25 (which corresponds to visible optical depth either less than or greater than about 0.5). For interests in aerocapture and precision entry and landing, comparisons focused on atmospheric density. TES densities versus height were computed from TES temperature versus pressure, using assumptions of perfect gas law and hydrostatics. Mars-GRAM validation studies used density ratio (TES/Mars-GRAM) evaluated at data bin center points in space and time. Observed average TES/Mars-GRAM density ratios were generally 1+/-0.05, except at high altitudes (15-30 km, depending on season) and high latitudes (> 45 deg N), or at most altitudes in the southern hemisphere at Ls approx. 90 and 180deg). Compared to TES averages for a given latitude and season, TES data had average density standard deviation about the mean of approx. 65-10.5% (varying with height) for all data, or approx. 5-12%, depending on time of day and dust optical depth. Average standard deviation of TES/Mars-GRAM density ratio was 8.9% for local time 2 hours and 7.1% for local time 14 hours. Thus standard deviation of observed TES/Mars-GRAM density ratio, evaluated at matching positions and times, is about the same as the standard deviation of TES data about the TES mean value at a given position and season.

Justus, C.↗

SERS Theory: The Chemical Effect of Rhodamine 6G Adsorption on Silver Surfaces on Its Raman Spectrum

The SERS spectra of small organic molecules can be very sensitive to the physisorption or chemisorption of the molecules onto metallic surfaces. However it is challenging to model the results, as typical SERS substrates have a broad distribution of possible surface sites, and the populations of these sites and the SERS enhancement factors associated with them are very difficult to determine, especially when electromagnetic hot spots dominate the observed spectra. However it is important to account for these effects if one is to make a quantitative interpretation of measured SERS spectra. Indeed, the influence of different sites is important to both the electromagnetic and chemical mechanisms in SERS, where the former mechanism is concerned with local field enhancement effects arising from plasmon excitation, while the latter arises from the effect of chemisorption induced charged transfer on the Raman intensities, as can be modeled using static limit Raman intensity calculations[1]. Extensive studies have been performed on simple organics like pyridine bound to gold and silver clusters, and it was found that both the chemical and electrodynamic enhancement factors associated with binding pyridine in various orientations result in noticeable changes in the SERS spectra compared to the gas phase spectrum of pyridine.[2] One of the most important benchmark molecules for SERS and TERS studies is Rhodamine 6G (R6G). This is a strongly fluorescent dye molecule in solution, but when adsorbed onto SERS substrates, its fluorescence is quenched, and the resulting SERS intensities are among the largest observed for any molecule. As a result R6G has played a crucial role in the development of single molecule SERS, and in the development of SERS substrates. [3, 4] Previously, the SERS spectrum of R6G has been modeled as if it were a gas phase molecule. Jensen and Schatz[5] incorporated resonant effects as well as vibronic effects and found that resonance excitation to the S1 excited state of R6G resulted in good agreement with spectra obtained from SERS experiments. In another study, intermolecular charge transfer was studied with R6G bound to a Ag2 cluster.[6] It is unclear if a cluster model as small as two silver atoms can accurately capture the surface effects of a nanoparticle with thousands of atoms. Recent single molecule, ultra high vacuum, tip enhanced Raman spectroscopy (SM-UHV-TERS) measurements for R6G[3] were moderately reproduced by gas phase resonance Raman calculations. Of particular importance in this work was the comparison of TERS spectra at room temperature with those at a low temperature of 10K. It was found that lowering the temperature led to both sharpening of the vibrational spectra, and shifts in the spectra (up to 20 cm-1 with some lines shifting red, some blue and some not at all), suggesting that the molecule transitions from a largely gas phase molecule at room temperature to being strongly chemisorbed at 10K. A potential energy distribution analysis performed by Chulhai and Jensen[3] showed that the modes that were shifted from the gas phase had vibrational activity associated with the ethylamine component of R6G, which is the likely moiety associated with Raman calculations. What remains unresolved concerning the SM-UHV-TERS studies of R6G is direct evidence that the chemical binding of R6G to a silver nanoparticle surfaces causes frequency shifts and/or intensity changes in the Raman scattering intensities of specific modes, especially those involving vibrations of the ethylamine moiety. The theoretical work described in this chapter directly addresses this issue by calculating Raman spectra for R6G interacting with a 20-atom silver cluster, and with a flat Ag(111) surface. Tetrahedral Ag20 is chosen for part of these studies as it provides a model nanoparticle structure that has a well-defined fragment of a (111) surface, as well as having edges and vertices that can be used to model coordinately unsaturated sites on a particle. In addition, Ag20 has been found to provide a reasonable reference structure for determining the chemical contribution to SERS enhancements.[1] Two different geometries of the Ag20/R6G system are considered in the present study, corresponding to two different binding configurations of R6G to a pristine Ag(111) surface. In addition, we study adsorption of R6G on a flat Ag(111) surface of using plane wave DFT calculations to determine optimized geometries and normal mode properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Dose Calculation on KV Cone Beam CT Images: An Investigation of the Hu-Density Conversion Stability and Dose Accuracy Using the Site-Specific Calibration

Precise calibration of Hounsfield units (HU) to electron density (HU-density) is essential to dose calculation. On-board kV cone beam computed tomography (CBCT) imaging is used predominantly for patients' positioning, but will potentially be used for dose calculation. The impacts of varying 3 imaging parameters (mAs, source-imager distance [SID], and cone angle) and phantom size on the HU number accuracy and HU-density calibrations for CBCT imaging were studied. We proposed a site-specific calibration method to achieve higher accuracy in CBCT image-based dose calculation. Three configurations of the Computerized Imaging Reference Systems (CIRS) water equivalent electron density phantom were used to simulate sites including head, lungs, and lower body (abdomen/pelvis). The planning computed tomography (CT) scan was used as the baseline for comparisons. CBCT scans of these phantom configurations were performed using Varian Trilogy{sup TM} system in a precalibrated mode with fixed tube voltage (125 kVp), but varied mAs, SID, and cone angle. An HU-density curve was generated and evaluated for each set of scan parameters. Three HU-density tables generated using different phantom configurations with the same imaging parameter settings were selected for dose calculation on CBCT images for an accuracy comparison. Changing mAs or SID had small impact on HU numbers. For adipose tissue, the HU discrepancy from the baseline was 20 HU in a small phantom, but 5 times lager in a large phantom. Yet, reducing the cone angle significantly decreases the HU discrepancy. The HU-density table was also affected accordingly. By performing dose comparison between CT and CBCT image-based plans, results showed that using the site-specific HU-density tables to calibrate CBCT images of different sites improves the dose accuracy to {approx}2%. Our phantom study showed that CBCT imaging can be a feasible option for dose computation in adaptive radiotherapy approach if the site-specific calibration is applied.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experimental and modeling study of the autoignition behavior of a saturated heterocycle: Pyrrolidine

Experiments are conducted in both rapid compression machine (RCM) and shock tube (ST) to better quantify autoignition behavior (e.g., ignition delay, heat release) and understand heteroatomic effects in heterocyclic compounds, which are important reference components for the combustion of biomass-derived liquid fuels. These tests focus on the nitrogen-containing, five-membered saturated ring, pyrrolidine, at diluted conditions covering pressures of 20 and 50 bar, temperatures of 720–1450 K and a range of stoichiometries (ϕ = 0.5–2). A chemical kinetic model is developed and coupled to an existing combustion kinetics framework describing key nitrogen containing intermediates (e.g. pyrrole, ammonia and NOx). H-abstraction reactions by OH, H, CH 3 and HO 2 , are determined using ab-initio transition state theory methods, while analogies to cyclopentane are adopted for many other reactions, such as ring-opening. Here, the autoignition measurements reveal the lack of negative temperature coefficient (NTC) behavior and low-temperature chemistry for pyrrolidine, as opposed to its saturated hydrocarbon analogue, cyclopentane. Interestingly, at the lowest temperatures (T < 750 K), the reactivity of cyclopentane is greater than pyrrolidine, while at higher temperatures, pyrrolidine becomes more reactive. Agreement between the experimental measurements and the model is good, and it is found that H-abstraction reactions by HO 2 and ensuing chemistry play key roles in controlling the reactivity of this cyclic amine. Most of the fluxes, i.e., >70 %, are predicted to move through 1- or 2-pyrroline (C 4 H 7 N) and then the cyclic C 4 H 6 N radical, at both lower and higher temperatures, to form either CH 2 CHCHCHNH via ring-opening or pyrrole via β-scission. It appears that the ring opens more easily at lower temperature whereas the C–H β-scission dominates at higher temperature and lower pressure, such that the reaction of the fuel radical intermediate carrying an unpaired electron on the nitrogen atom with HO 2 is the next most notable in promoting oxidation. When comparing pyrrolidine and cyclopentane, which exhibits distinct pathways in different temperature regimes, the pyrrolidine pathways and sensitivity analysis align more closely to the high temperature case of cyclopentane where the important role of HO 2 radicals is seen to provide chain branching through HO 2 reaction with the fuel, accompanied by H 2 O 2 formation and decomposition to OH. The formation of 5-membered diene rings and ring opening reactions are also found to be highly relevant. Of particular note, it is found that there is little influence of small molecule nitrogen-chemistry, e.g., NH 2 , HCN, NO/NO 2 on the reactivity of the pyrrolidine mixtures investigated here where no recirculated combustion gases are included.

Autoignition↗

Flight Mechanics Modeling and Simulation of the Earth Entry System

Introduction: The Mars Sample Return (MSR) Campaign being planned by NASA and ESA has the ambitious goal to return Mars samples back to Earth. This international collaboration had developed a concept of operations that included a ESA-designed Earth Return Orbiter (ERO) and NASA-designed Capture, Containment, and Return System (CCRS). The Earth Entry System (EES), consisting of a protective aeroshell that houses the samples as well as sample containment vessels, would conduct entry, descent, and landing (EDL) on a direct Earth trajectory. The EES would enter on a spin-stabilized ballistic trajectory with the goal to passively achieve aerodynamic stability throughout all regions of flight. The EDL sequence would end with the EES impacting the soft playa soil of the Utah Test and Training Range (UTTR). As of the submission of this abstract, the MSR campaign is undergoing a re-architecture leading to a pause in EES development. However, the novel approaches developed in flight mechanics modeling and simulation can significantly benefit the greater IPPW community in the development of Earth return vehicles. This paper will present the latest state of EES flight mechanics modeling and simulation. The paper will highlight the simulation architecture developed and key lessons learned from understanding of EDL trajectory sensitivities. Modeling and Simulation: Figure 1 provides a high-level concept of operations for the approach, entry, descent, and landing (AEDL) phase of the CCRS-portion of MSR. The objective of EES flight mechanics is to model and simulate the EES trajectory from ERO separation to ground impact at UTTR. A variety of flight mechanics simulation models were utilized to model both exo-atmopsheric and atmospheric portions of flight. 42, a 6-DOF simulation developed at Goddard Space Flight Center, is utilized for propagating the attitude of EES during exo-atmospheric flight. 42 allows for a variety of spin eject mechanism scenarios to be simulated for analysis. 10 minutes prior to entry, the 42 states are handed off to the EDL sims. The prime EDL sim utilized by EES is the Program to Optimize Simulated Trajectories II (POST2), a 6-DOF sim developed at Langley Research Center, and the independent verification and validation EDL sim utilized is DSENDS, a 6-DOF sim developed at Jet Propulsion Laboratory. Figure 2 provides a visualization of the flight mechanics simulation model flow through various points in the AEDL phase. Due to the existence of a variety of sim models, the EES flight mechanics team developed processes for data hand-off. These processes included the development of a centralized coordinate frame document, utilization of a single, centralized simulation input document for all sims to reference, and hand-off files containing both the technical data to be ingested by other flight mechanics sims as well as annotations of modeling assumptions utilized to generate the data. Figure~\ref{fig:post2simarchitecture} provides an overview of the POST2 sim architecture wherein POST2 ingests numerous subsystem models and input files. The dispersed state file generated by MONTE provides the position/velocity state of the trajectory while the 42 Handoff file provides the attitude. The aerodynamics database, delivered by the EES aeroscience team, is utilized to simulate the aerodynamic forces and moments experienced during EDL. A custom atmosphere model, developed by EES atmosphere team, is utilized to simulate the anticipated atmosphere environment around the region of Earth through which the EES trajectory flys. These inputs and subsystem models can be varied depending on the AEDL flight mechanics scenario being simulated. Monte Carlo simulations are utilized to generate statistical AEDL performance metrics in the form of scorecards and violin plots. Furthermore, outputs from the POST2 simulation are utilized for follow-on analyses including aerothermal and landing performance. \section{Flight Mechanics Lessons Learned} Though the EES flight mechanics team uncovered a variety of lessons learned through the analysis conducted to support CCRS through preliminary design review, this paper will highlight the most important lessons. A key AEDL performance goal is to ensure the landing footprint of EES remains on the UTTR south range. A common modeling strategy used in EDL analysis is One-Variable-At-a-Time (OVAT). OVAT analysis provides insight into the key drivers that affect AEDL performance metrics. Figure 3 shows the landing ellipses for single dispersion sources as compared to the baseline aggregate of all dispersions. The figure shows that atmosphere winds alone dominate the size of the footprint ellipse (note: EES does not use a parachute unlike previous Earth-return missions and is in wind-driven free fall for ~5min). The significance of the wind led the EES flight mechanics team to pursue the development of a Custom Atmosphere Model [4], in lieu of EarthGRAM [1], built on actual radiosonde wind measurements around the UTTR-region. This decision was driven by the realism in the generated footprint ellipses and lessons-learned from Stardust [5]. These findings will be invaluable for future Earth-return missions in providing an early understanding of the key drivers affecting footprint size and modeling considerations for which to account. Another lesson learned is tied to the AEDL performance goal of achieving passive stability throughout all regions of flight. It is well understood that blunt-body aeroshells are less stable as they transition from supersonic to subsonic. Eliminating a backshell does help improvestability; however, other phenomena such as roll-induced instability during terminal descent can still arise. The EES flight mechanics team developed stability metrics as tools to better understand the causes of and better predict the onset of dynamic instability. These tools were built upon analytical models developed by Jaffe [3] and Murphy [2]. The tools were shown to both be very accurate in correlation with actual unstable cases and useful in developing stability margin policies based on the vehicle design and simulation considerations (e.g. sphere-cone angle change, mass change, wind turbulence). These tools allowed for the current EES design to demonstrate the ability to achieve passive stability and can be an invaluable tool for consideration in the design of parachute-less Earth-return vehicles.

Rohan Deshmukh↗

Greenbuilt Construction Energy Efficiency Retrofit House Demonstration - Sacramento

One of the homes that was part of Sacramento Municipal Utility District's (SMUD) Energy Efficiency Retrofit Demonstration (EERD) project was a 1980's era home in Fair Oaks, California, referred to as the Greenbuilt house, as Greenbuilt Construction completed the retrofit of the home. The home underwent an extensive energy efficiency retrofit with a goal of achieving a 50% reduction in energy use to demonstrate the potential for other builders and homeowners in the area. The retrofit measures included installing: ENERGY STAR appliances high efficiency light roof radiant barrier additional ceiling and wall insulation double-pane, low-e windows external motorized shading and solar tubes a 16 SEER/9.75 HSPF heat pump improved ducts a whole-house fan a heat pump water heater (HPWH) integrated collector storage solar water heater (ICS SWH) and 3.2 kW of PV. In addition, the home was air sealed to reduce infiltration. Researchers from the National Renewable Energy Laboratory (NREL) performed short-term tests on the major systems installed as part of the retrofit to ensure that they were performing as expected. The systems evaluated included the space conditioning heat pump, the air handler and ducts, the HPWH, the ICS SWH, and the PV array. Some ducts were untwisted after testing revealed that two rooms were not getting sufficient airflow. Afterwards, all systems were performing as expected. In addition to testing to confirm adequate performance of all new systems, NREL was given the opportunity to use the Greenbuilt house as a laboratory house for a year. The space conditioning system and home water systems were subjected to a series of tests to determine optimal control strategies for lowering energy consumption and reducing peak (4:00-7:00 p.m.) energy consumption during the summer. The different cooling strategies considered included two different precooling schedules, drawing the external shades during the day and using the whole-house fan at night, and combinations of those. The most effective strategy for reducing overall energy consumption was the use of external shades, which cut the daily cooling load by 34% and reduced the energy use during peak hours by 40%. The different precooling strategies eliminated the peak load entirely but actually increased daily cooling energy use. The use of shades and the advanced precooling strategy increased the daily energy use by 5% but eliminated all peak use and maintained a comfortable home. These results were verified over the entire summer using an Energy Plus model of the home. The hot water system was tested in two configurations: the HPWH alone and the ICS solar water heater paired with the HPWH. Six hot water draw profiles, varying in terms of daily hot water volume, time of day for hot water use, and the duration of the draws, were imposed on the hot water system to test their effects on performance. When operating alone in the summer, the HPWH operated with a COP around 2.2, except for a draw that used a quarter of the averaged daily hot water usage, which had an average COP of 1.6. The combination of ICS and HPWH resulted in larger COPs, but also more variability depending on the draw profile. The standard, hourly draw profile produced the highest COP of 6.4. The quarter volume draw profile had the lowest COP of 2.8 for the combined system. Relative to a standard electric water heater, the HPWH operating alone reduced the peak load by 56% and the combined ICS and HPWH system completely eliminated the peak load.

air sealing↗

PERFORMANCE EVALUATION OF A SUSTAINABLE AND ENERGY EFFICIENT RE-ROOFING TECHNOLOGY USING FIELD-TEST DATA

Three test attics were constructed to evaluate a new sustainable method of re-roofing utilizing photo-voltaic (PV) laminates, metal roofing panels, and PCM heat sink in the Envelope Systems Research Apparatus (ESRA) facility in the ORNL campus. Figure 1 is a picture of the three attic roofs located adjacent to each other. The leftmost roof is the conventional shingle roof, followed by the metal panel roof incorporating the cool-roof coating, and third from left is the roof with the PCM. On the PCM roof, the PV panels are seen as well; they're labelled from left-to-right as panels 5, 6 and 7. The metal panel roof consists of three metal panels with the cool-roof coating; in further discussion this is referred to as the infrared reflective (IRR) metal roof. The IRR metal panels reflect the incoming solar radiation and then quickly re-emit the remaining absorbed portion, thereby reducing the solar heat gain of the attic. Surface reflectance of the panels were measured using a Solar Spectrum Reflectometer. In the 0.35-2.0 {mu}m wavelength interval, which accounts for more than 94% of the solar energy, the IRR panels have an average reflectance of 0.303. In the infrared portion of the spectrum, the IRR panel reflectance is 0.633. The PCM roof consists of a layer of macro-encapsulated bio-based PCM at the bottom, followed by a 2-cm thick layer of dense fiberglass insulation with a reflective surface on top, and metal panels with pre-installed PV laminates on top. The PCM has a melting point of 29 C (84.2 F) and total enthalpy between 180 and 190 J/g. The PCM was macro-packaged in between two layers of heavy-duty plastic foil forming arrays of PCM cells. Two air cavities, between PCM cells and above the fiberglass insulation, helped the over-the-deck natural air ventilation. It is anticipated that during summer, this extra ventilation will help in reducing the attic-generated cooling loads. The extra ventilation, in conjunction with the PCM heat sink, are used to minimize thermal stresses due to the PV laminates on sunny days. In PV laminates sunlight is converted into electricity and heat simultaneous. In case of building integrated applications, a relatively high solar absorption of amorphous silicon laminates can be utilized during the winter for solar heating purposes with PCM providing necessary heat storage capacity. However, PV laminates may also generate increased building cooling loads during the summer months. Therefore, in this project, the PCM heat sink was to minimize summer heat gains as well. The PCM-fibreglass-PV assembly and the IRR metal panels are capable of being installed directly on top of existing shingle roofs during re-roofing, precluding the need for recycling or disposal of waste materials. The PV laminates installed on the PCM attic are PVL-144 models from Uni-Solar. Each laminate contains 22 triple junction amorphous silicon solar cells connected in series. The silicon cells are of dimensions 356 mm x 239 mm (14-in. x 9.4-in.). The PVL-144 laminate is encapsulated in durable ETFE (poly-ethylene-co-tetrafluoroethylene) high light-transmissive polymer. Table 1 lists the power, voltage and current ratings of the PVL-144 panel.

14 SOLAR ENERGY↗

Pre-Project Planning for a Flameless Pressurized Oxy-Combustion Pilot Plant (Final Technical Report)

The team of Southwest Research Institute® (SwRI®), ITEA, Electric Power Research Institute, Inc. (EPRI), GE Global Research (GE), Jacobs Engineering (Jacobs), and Peter Reineck Associates (PRA) are advancing Flameless Pressurized Oxy-Combustion (FPO), a novel coal technology. This effort seeks to complete the preliminary engineering and planning of a 50-MWth Pilot Plant that produces electricity and steam for district heating. The technology, pioneered by ITEA at the 5-MWth scale, must be brought to a higher technology readiness level (TRL) to be viable at the commercial scale. This project builds upon extensive evaluation of the techno-economic performance of the FPO technology already performed by ITEA. This includes system improvements, such as the addition of a turbo-expander to the flue gas stream. Some of the performance-enhancing components are not as well defined as others. The primary goal of this project was to bring all of the core cycle components to the same level of design maturity. Extensive cycle modeling and evaluation explored various configurations of the process. Different coals, operating conditions, and heat recovery devices were considered and modeled using Aspen Plus. The results of the cycle modeling informed the pilot plant configuration and the planned configuration at the commercial scale. The system pressurization is maintained in the flue gas clean-up and water removal. This allows for efficient and cost-effective carbon dioxide compression and sequestration package. Once the cycle was optimized, preliminary drawings, layouts, and plans defined the pilot facility. Process flow diagrams (PFD) were used to describe the pilot configuration in greater detail. A heat and mass balance with stream data was created. A master equipment list specified the operating conditions for major pieces of equipment within the pilot using this heat and mass balance. A detailed cost estimate for the planned configuration was completed with an Association for the Advancement of Cost Engineering (AACE) Class IV level of cost analysis. A site selection effort evaluated a variety of potential candidate sites. The selection effort focused on three sites for an in-depth evaluation of the merits and viability of hosting a pilot demonstration. The ability of the host site to support the project with cost sharing was also assessed. The selection process chose the University of Wyoming (UW) as the host site, and cost estimates for the pilot capital estimate were made using local data. A preliminary test plan and operation plan, which creates figures of merit, control, and instrumentation was produced. An effort that outlines methods of pilot cost reduction was completed near the end of the project. A techno-economic assessment (TEA) evaluated the FPO technology at the commercial scale in comparison to the NETL baseline cases. The reference plants were used in combination with proprietary equipment estimates to build a plant capital cost and cost of electricity evaluation. FPO performed better than the sub-bituminous post-combustion capture cases. Further preliminary estimates of improvements to the FPO cycle show even further gains when compared to conventional carbon capture methods.

01 COAL, LIGNITE, AND PEAT↗

Determination of the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for detectors used with an 800 MU/min CyberKnife{sup ®} system equipped with fixed collimators and a study of detector response to small photon beams using a Monte Carlo method

Purpose: In a previous work, output ratio (OR{sub det}) measurements were performed for the 800 MU/min CyberKnife{sup ®} at the Oscar Lambret Center (COL, France) using several commercially available detectors as well as using two passive dosimeters (EBT2 radiochromic film and micro-LiF TLD-700). The primary aim of the present work was to determine by Monte Carlo calculations the output factor in water (OF{sub MC,w}) and the k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors. The secondary aim was to study the detector response in small beams using Monte Carlo simulation. Methods: The LINAC head of the CyberKnife{sup ®} was modeled using the PENELOPE Monte Carlo code system. The primary electron beam was modeled using a monoenergetic source with a radial gaussian distribution. The model was adjusted by comparisons between calculated and measured lateral profiles and tissue-phantom ratios obtained with the largest field. In addition, the PTW 60016 and 60017 diodes, PTW 60003 diamond, and micro-LiF were modeled. Output ratios with modeled detectors (OR{sub MC,det}) and OF{sub MC,w} were calculated and compared to measurements, in order to validate the model for smallest fields and to calculate k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors, respectively. For the study of the influence of detector characteristics on their response in small beams; first, the impact of the atomic composition and the mass density of silicon, LiF, and diamond materials were investigated; second, the material, the volume averaging, and the coating effects of detecting material on the detector responses were estimated. Finally, the influence of the size of silicon chip on diode response was investigated. Results: Looking at measurement ratios (uncorrected output factors) compared to the OF{sub MC,w}, the PTW 60016, 60017 and Sun Nuclear EDGE diodes systematically over-responded (about +6% for the 5 mm field), whereas the PTW 31014 Pinpoint chamber systematically under-responded (about −12% for the 5 mm field). OR{sub det} measured with the SFD diode and PTW 60003 diamond detectors were in good agreement with OF{sub MC,w} except for the 5 mm field size (about −7.5% for the diamond and +3% for the SFD). A good agreement with OF{sub MC,w} was obtained with the EBT2 film and micro-LiF dosimeters (deviation less than 1.4% for all fields investigated). k{sub Q{sub c{sub l{sub i{sub n,Q{sub m{sub s{sub r}{sup f{sub c}{sub l}{sub i}{sub n},f{sub m}{sub s}{sub r}}}}}}}}} correction factors for several detectors used in this work have been calculated. The impact of atomic composition on the dosimetric response of detectors was found to be insignificant, unlike the mass density and size of the detecting material. Conclusions: The results obtained with the passive dosimeters showed that they can be used for small beam OF measurements without correction factors. The study of detector response showed that OR{sub det} is depending on the mass density, the volume averaging, and the coating effects of the detecting material. Each effect was quantified for the PTW 60016 and 60017 diodes, the micro-LiF, and the PTW 60003 diamond detectors. None of the active detectors used in this work can be recommended as a reference for small field dosimetry, but an improved diode detector with a smaller silicon chip coated with tissue-equivalent material is anticipated (by simulation) to be a reliable small field dosimetric detector in a nonequilibrium field.

07 ISOTOPE AND RADIATION SOURCES↗

AGR-2 Daily As-run Thermal Analyses

This report documents the daily as-run thermal analyses performed on Advanced Gas-cooled Reactor (AGR) experiment AGR-2 in the Advanced Test Reactor (ATR) for capsules 2,3,5, and 6. Capsule 1 (French) results are in Appendix F, while Capsule 4 (South African) results are in Appendix G. Appendix F, and G are separate documents Several fuel and material irradiation experiments, which support the development of the Next Generation Nuclear Plant (NGNP), are planned for the Advanced Gas Reactor Fuel Development and Qualification Program. The goals of these experiments are to provide irradiation performance data to support fuel process development, to qualify fuel for normal operating conditions, to support development and validation of fuel performance and fission product transport models and codes, and to provide irradiated fuel and materials for post-irradiation examination (PIE) and safety testing. AGR-2 was the second in this series of planned experiments to test tristructural-isotropic (TRISO)-coated, low enriched uranium oxycarbide (LEUCO) fuel. The AGR-2 experiment was intended to serve as a follow-on to the AGR-1 experiment. The AGR-2 experiment is a high temperature fuel particle test. The test train planned for AGR-2 is based on the experience gained from previous irradiations in the ATR, using instrumented lead experiments. Instrumented lead experiments are used for irradiations requiring a controlled environment and monitored parameters. The experiment test train positions the fuel within the test location and contains sweep gas lines and thermocouple wiring that is routed through access ports to external support systems. The AGR-2 experiment is comprised of six individual capsules, approximately 1.375-in. in diameter by 6-in. long, stacked on top of each other to form the test train. Each capsule contains 12 fueled compacts that are approximately 0.5-in. in diameter by 1-in. long. The compacts are composed of fuel particles bound together by a carbon matrix. Each compact contains approximately 4,150 fissile particles (35 vol% particle packing fraction). Each capsule will be supplied with a flowing helium/neon gas mixture to control the test temperature and to sweep any fission gases that are released to the fission product monitoring system. Temperature control is accomplished by adjusting the gas mixture ratio of the two gases (helium and neon) with differing thermal conductivities. Many similarities exist between this thermal analysis for AGR-2 with the AGR-1 daily as-run report in [1]. Gas gaps were taken from as built drawings in Reference [2]. The finite element heat transfer code ABAQUS [3] was used to perform the thermal analysis. The AGR-2 experiment was placed in the B-12 position in the ATR core as shown in Figure 1. The AGR-2 experiment capsule assembly consists of six capsules axially stacked. Each capsule contains a graphite holder with three equally spaced fuel compact holder openings as shown in Figure 2. Each holder opening accommodates four axially stacked fuel compacts. Thus, each capsule has three stacks by four fuel compacts per stack for a total of 12 fuel compacts per capsule. So, within the entire AGR-2 experiment capsule assembly, there are six capsules by 12 fuel compacts per capsule for a total of 72 fuel compacts. Six finite element heat transfer models were created (one for each capsule), each with a corresponding gas gap.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lawrence Livermore National Laboratory Emergency Response Capability Baseline Needs Assessment Requirement Document

This revision of the LLNL Fire Protection Baseline Needs Assessment (BNA) was prepared by John A. Sharry, LLNL Fire Marshal and LLNL Division Leader for Fire Protection and reviewed by Martin Gresho, Sandia/CA Fire Marshal. The document follows and expands upon the format and contents of the DOE Model Fire Protection Baseline Capabilities Assessment document contained on the DOE Fire Protection Web Site, but only address emergency response. The original LLNL BNA was created on April 23, 1997 as a means of collecting all requirements concerning emergency response capabilities at LLNL (including response to emergencies at Sandia/CA) into one BNA document. The original BNA documented the basis for emergency response, emergency personnel staffing, and emergency response equipment over the years. The BNA has been updated and reissued five times since in 1998, 1999, 2000, 2002, and 2004. A significant format change was performed in the 2004 update of the BNA in that it was 'zero based.' Starting with the requirement documents, the 2004 BNA evaluated the requirements, and determined minimum needs without regard to previous evaluations. This 2010 update maintains the same basic format and requirements as the 2004 BNA. In this 2010 BNA, as in the previous BNA, the document has been intentionally divided into two separate documents - the needs assessment (1) and the compliance assessment (2). The needs assessment will be referred to as the BNA and the compliance assessment will be referred to as the BNA Compliance Assessment. The primary driver for separation is that the needs assessment identifies the detailed applicable regulations (primarily NFPA Standards) for emergency response capabilities based on the hazards present at LLNL and Sandia/CA and the geographical location of the facilities. The needs assessment also identifies areas where the modification of the requirements in the applicable NFPA standards is appropriate, due to the improved fire protection provided, the remote location and low population density of some the facilities. As such, the needs assessment contains equivalencies to the applicable requirements. The compliance assessment contains no such equivalencies and simply assesses the existing emergency response resources to the requirements of the BNA and can be updated as compliance changes independent of the BNA update schedule. There are numerous NFPA codes and standards and other requirements and guidance documents that address the subject of emergency response. These requirements documents are not always well coordinated and may contain duplicative or conflicting requirements or even coverage gaps. Left unaddressed, this regulatory situation results in frequent interpretation of requirements documents. Different interpretations can then lead to inconsistent implementation. This BNA addresses this situation by compiling applicable requirements from all identified sources (see Section 5) and analyzing them collectively to address conflict and overlap as applicable to the hazards presented by the LLNL and Sandia/CA sites (see Section 7). The BNA also generates requirements when needed to fill any identified gaps in regulatory coverage. Finally, the BNA produces a customized simple set of requirements, appropriate for the DOE protection goals, such as those defined in DOE O 420.1B, the hazard level, the population density, the topography, and the site layout at LLNL and Sandia/CA that will be used as the baseline requirements set - the 'baseline needs' - for emergency response at LLNL and Sandia/CA. A template approach is utilized to accomplish this evaluation for each of the nine topical areas that comprise the baseline needs for emergency response. The basis for conclusions reached in determining the baseline needs for each of the topical areas is presented in Sections 7.1 through 7.9. This BNA identifies only mandatory requirements and establishes the minimum performance criteria. The minimum performance criteria may not be the level of performance desired Lawrence Livermore National Laboratory or Sandia/CA. Performance at levels greater than those established by this document will provide a higher level of fire safety, fire protection, or loss control and is encouraged. In Section 7, Determination of Baseline Needs, a standard template was used to describe the process used that involves separating basic emergency response needs into nine separate services. Each service being evaluated contains a determination of minimum requirements, an analysis of the requirements, a statement of minimum performance, and finally a summary of the minimum performance. The requirement documents, listed in Section 5, are those laws, regulations, DOE Directives, contractual obligations, or LLNL policies that establish service levels. The determination of minimum requirements section explains the rationale or method used to determine the minimum requirements.

99 GENERAL AND MISCELLANEOUS↗

Patient-specific radiation dose and cancer risk estimation in CT: Part II. Application to patients

Purpose: Current methods for estimating and reporting radiation dose from CT examinations are largely patient-generic; the body size and hence dose variation from patient to patient is not reflected. Furthermore, the current protocol designs rely on dose as a surrogate for the risk of cancer incidence, neglecting the strong dependence of risk on age and gender. The purpose of this study was to develop a method for estimating patient-specific radiation dose and cancer risk from CT examinations. Methods: The study included two patients (a 5-week-old female patient and a 12-year-old male patient), who underwent 64-slice CT examinations (LightSpeed VCT, GE Healthcare) of the chest, abdomen, and pelvis at our institution in 2006. For each patient, a nonuniform rational B-spine (NURBS) based full-body computer model was created based on the patient's clinical CT data. Large organs and structures inside the image volume were individually segmented and modeled. Other organs were created by transforming an existing adult male or female full-body computer model (developed from visible human data) to match the framework defined by the segmented organs, referencing the organ volume and anthropometry data in ICRP Publication 89. A Monte Carlo program previously developed and validated for dose simulation on the LightSpeed VCT scanner was used to estimate patient-specific organ dose, from which effective dose and risks of cancer incidence were derived. Patient-specific organ dose and effective dose were compared with patient-generic CT dose quantities in current clinical use: the volume-weighted CT dose index (CTDI{sub vol}) and the effective dose derived from the dose-length product (DLP). Results: The effective dose for the CT examination of the newborn patient (5.7 mSv) was higher but comparable to that for the CT examination of the teenager patient (4.9 mSv) due to the size-based clinical CT protocols at our institution, which employ lower scan techniques for smaller patients. However, the overall risk of cancer incidence attributable to the CT examination was much higher for the newborn (2.4 in 1000) than for the teenager (0.7 in 1000). For the two pediatric-aged patients in our study, CTDI{sub vol} underestimated dose to large organs in the scan coverage by 30%-48%. The effective dose derived from DLP using published conversion coefficients differed from that calculated using patient-specific organ dose values by -57% to 13%, when the tissue weighting factors of ICRP 60 were used, and by -63% to 28%, when the tissue weighting factors of ICRP 103 were used. Conclusions: It is possible to estimate patient-specific radiation dose and cancer risk from CT examinations by combining a validated Monte Carlo program with patient-specific anatomical models that are derived from the patients' clinical CT data and supplemented by transformed models of reference adults. With the construction of a large library of patient-specific computer models encompassing patients of all ages and weight percentiles, dose and risk can be estimated for any patient prior to or after a CT examination. Such information may aid in decisions for image utilization and can further guide the design and optimization of CT technologies and scan protocols.

60 APPLIED LIFE SCIENCES↗

Multigrid Methods for EHL Problems

In many bearings and contacts, forces are transmitted through thin continuous fluid films which separate two contacting elements. Objects in contact are normally subjected to friction and wear which can be reduced effectively by using lubricants. If the lubricant film is sufficiently thin to prevent the opposing solids from coming into contact and carries the entire load, then we have hydrodynamic lubrication, where the lubricant film is determined by the motion and geometry of the solids. However, for loaded contacts of low geometrical conformity, such as gears, rolling contact bearings and cams, this is not the case due to high pressures and this is referred to as Elasto-Hydrodynamic Lubrication (EHL) In EHL, elastic deformation of the contacting elements and the increase in fluid viscosity with pressure are very significant and cannot be ignored. Since the deformation results in changing the geometry of the lubricating film, which in turn determines the pressure distribution, an EHL mathematical model must simultaneously satisfy the complex elasticity (integral) and the Reynolds lubrication (differential) equations. The nonlinear and coupled nature of the two equations makes numerical calculations computationally intensive. This is especially true for highly loaded problems found in practice. One novel feature of these problems is that the solution may exhibit sharp pressure spikes in the outlet region. To this date both finite element and finite difference methods have been used to solve EHL problems with perhaps greater emphasis on the use of the finite difference approach. In both cases, a major computational difficulty is ensuring convergence of the nonlinear equations solver to a steady state solution. Two successful methods for achieving this are direct iteration and multigrid methods. Direct iteration methods (e.g Gauss Seidel) have long been used in conjunction with finite difference discretizations on regular meshes. Perhaps one of the best examples of the application of such methods is the recent Effective Influence Method of Dowson and Wang. Multigrid methods have also been used with great success by Venner and Venner and Lubrecht with a good summary being given by Venner. As both these finite difference discretization based approaches appear to provide an efficient way of solving EHL problems, it is important to understand their relative merits. This paper is a first attempt at providing such an understanding in the context of EHL point contact problem, (contact of two spheres), in which the contact zone is a point and an ellipse or circle for unloaded and loaded dry contacts respectively. Since the film thickness and the contact width are generally small compared to the local radius of curvature of the two surfaces, the reduced geometry of the surfaces in the contact area can be accurately approximated to the contact between a paraboloid and a flat surface. The layout of the remainder of this paper is as follows. In section 2 we introduce the form of the equations to be solved. The Effective Influence Newton Method is described in Section 3 while Section 4 describes the Multigrid method to be used. Sections 5 and 6 describe the test problems to be used in the comparison between the two methods and compare the performance of the two methods. Section 7 concludes the paper with an argument of the two methods and suggests some future research directions.

Nurgat, Elyas↗

Hawaii Wave Surge Energy Converter (HAWSEC) OSU O.H. Hinsdale Basin

The following information and metadata applies to both the Phase I (Hydrodynamics) and Phase II (Full System Power Take-Off) zip folders which contain testing data from the OSU (Oregon State University) O.H. Hinsdale Wave Research Laboratory, from both OSU and the University of Hawaii at Manoa (UH). See zip folders provided further below in the downloads section. For experimental data of the full system, including PTO, see Phase II dataset. There are two main directories in each Phases's zip folder: "OSU_data" and "UH_data". The "OSU_data" directory contains data collected from their DAQ (data acquisition system), which includes all wave gauge observations, as well as body motions derived from their Qualisys motion tracking system. The organization of the directory follows OSU's convention. Detailed information on the instrument setup can be found under "OSU_data/docs/setup/instm_locations". The experiments conducted are documented in the "OSU_data/docs/daq_logs", which provides the trial number to the corresponding data located under "OSU_data/data" in several formats (e.g., ".mat" and ".txt"). Inside the trial directory, data is provided for each of the instruments defined in "OSU_data/docs/setup/instm_locations". The "UH_data" directory contains data collected from their DAQ. The data is stored in a ".tdms" file format. There are free plug-ins for Microsoft Excel and MathWorks MATLAB to read the ".tdms" format. Below are a few links providing methods to read in the data, but a Google search should identify alternatives sources if these no longer exist (valid as of January 2024): Excel: http://www.ni.com/example/27944/en/ MATLAB: https://www.mathworks.com/matlabcentral/fileexchange/30023-tdms-reader The Excel plugin is recommend to get a quick overview of the data. The UH data is organized by directory name, in which the sub-directories for each experiment contains a directory whose name defines the wave height and period for the experimental data within. For example, a directory name "H02_T0275" corresponds to an experiment with wave height 0.1m and a period of 2.75s. For random wave data, the gamma value is also included in the directory name. For example, a directory name "H02_T0225_G18" corresponds to an experiment with a significant wave height of 0.2m, a peak period of 2.25s, and a gamma value of 1.8, with each spectra being a TMA spectrum. For the free decay experiments, the directory name is defined by the initial angular displacement. For example, a directory name "ang05_run01" corresponds to an experiment with an initial angular displacement of 5 degrees. There is a dataset in the UH data for each corresponding experiment defined in the OSU DAQ logs. The ".tdms" data is output from the DAQ at fixed intervals. Therefore, if multiple files are contained within the folder, the data will need to be stitched together. Within the UH dataset, there are two input channels from the OSU DAQ providing a random square wave signal for time synchronization ("ENV-WHT-0010") and a high/low signal ("ENV-WHT-0012") to identify when the wave maker is active (+5V). The UH data is logged as a collection of channel outputs. Channels not in use for the OSU testing (either Phase I or Phase II) are marked "nan" below. If the sensor is disconnected, it will record noise throughout the experiment. Below are the channel definitions in terms of what they measure: GPS Time = time CYL-POS-0001 = position between flap and fixed reference CYL-LCA-0001 = force between flap and hydraulic cylinder REC-LPT-0001 = nan REC-HPT-0001 = nan REC-HPT-0002 = nan REC-HPT-0003 = nan HHT-HPT-0001 = pressure at exhaust ("head" only) REC-FQC-0001 = nan REC-FQC-0002 = nan HHT-FQC-0001 = flow at exhaust ("head" only) ENV-WHT-0001 = nan ENV-WHT-0002 = nan ENV-WHT-0003 = nan ENV-WHT-0010 = random signal from OSU DAQ ENV-WHT-0012 = high/low signal from OSU DAQ Also included is a calibration curve to convert the string pot data to flap pi...

16 TIDAL AND WAVE POWER↗

Climate Quality Broadband and Narrowband Solar Reflected Radiance Calibration Between Sensors in Orbit

vAs the potential impacts of global climate change become more clear [1], the need to determine the accuracy of climate prediction over decade-to-century time scales has become an urgent and critical challenge. The most critical tests of climate model predictions will occur using observations of decadal changes in climate forcing, response, and feedback variables. Many of these key climate variables are observed by remotely sensing the global distribution of reflected solar spectral and broadband radiance. These "reflected solar" variables include aerosols, clouds, radiative fluxes, snow, ice, vegetation, ocean color, and land cover. Achieving sufficient satellite instrument accuracy, stability, and overlap to rigorously observe decadal change signals has proven very difficult in most cases and has not yet been achieved in others [2]. One of the earliest efforts to make climate quality observations was for Earth Radiation Budget: Nimbus 6/7 in the late 1970s, ERBE in the 1980s/90s, and CERES in 2000s are examples of the most complete global records. The recent CERES data products have carried out the most extensive intercomparisons because if the need to merge data from up to 11 instruments (CERES, MODIS, geostationary imagers) on 7 spacecraft (Terra, Aqua, and 5 geostationary) for any given month. In order to achieve climate calibration for cloud feedbacks, the radiative effect of clear-sky, all-sky, and cloud radiative effect must all be made with very high stability and accuracy. For shortwave solar reflected flux, even the 1% CERES broadband absolute accuracy (1-sigma confidence bound) is not sufficient to allow gaps in the radiation record for decadal climate change. Typical absolute accuracy for the best narrowband sensors like SeaWiFS, MISR, and MODIS range from 2 to 4% (1-sigma). IPCC greenhouse gas radiative forcing is approx. 0.6 W/sq m per decade or 0.6% of the global mean shortwave reflected flux, so that a 50% cloud feedback would change the global reflected flux by approx. 0.3 W/sq m or 0.3% per decade in broadband SW calibration change. Recent results comparing CERES reflected flux changes with MODIS, MISR, and SeaWiFS narrowband changes concluded that only SeaWiFS and CERES were approaching sufficient stability in calibration for decadal climate change [3]. Results using deep convective clouds in the optically thick limit as a stability target may prove very effective for improving past data sets like ISCCP. Results for intercalibration of geostationary imagers to CERES using an entire month of regional nearly coincident data demonstrates new approaches to constraining the calibration of current geostationary imagers. The new Decadal Survey Mission CLARREO is examining future approaches to a "NIST-in-Orbit" approach of very high absolute accuracy reference radiometers that cover the full solar and infrared spectrum at high spectral resolution but at low spatial resolution. Sampling studies have shown that a precessing CLARREO mission could calibrate other geo and leo reflected solar radiation and thermal infrared sensors.

Wielicki, Bruce A.↗