Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reliability & Maintainability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Vision for cross-layer optimization to address the dual challenges of energy and reliability

We are rapidly approaching an inflection point where the conventional target of producing perfect, identical transistors that operate without upset can no longer be maintained while continuing to reduce the energy per operation. With power requirements already limiting chip performance, continuing to demand perfect, upset-free transistors would mean the end of scaling benefits. The big challenges in device variability and reliability are driven by uncommon tails in distributions, infrequent upsets, one-size-fits-all technology requirements, and a lack of information about the context of each operation. Solutions co-designed across traditional layer boundaries in our system stack can change the game, allowing architecture and software (a) to compensate for uncommon variation, environments, and events, (b) to pass down invariants and requirements for the computation, and (c) to monitor the health of collections of deVices. Cross-layer codesign provides a path to continue extracting benefits from further scaled technologies despite the fact that they may be less predictable and more variable. While some limited multi-layer mitigation strategies do exist, to move forward redefining traditional layer abstractions and developing a framework that facilitates cross-layer collaboration is necessary.

97 MATHEMATICS AND COMPUTING↗

The git based ATLAS data acquisition configuration service in LHC Run 3

The ATLAS experiment at the LHC at CERN uses a large, distributed trigger and data acquisition system composed of many computing nodes, networks, and hardware modules. Its configuration service is used to provide descriptions of control, monitoring, diagnostic, recovery, dataflow and data quality configurations, interconnections, and parameters for modules, chips, and channels of various online systems, detectors, and the whole ATLAS experiment. Those descriptions have historically been stored in more than one thousand interconnected XML files, which are updated by various experts many times per day. Maintaining error-free and consistent sets of such files and providing reliable and fast access to current and historical configurations is a major challenge. This paper gives details of the configuration service upgrade on the modern Git version control system backend for LHC Run 3 and its exploitation experience. It may be interesting for developers using human-readable file formats, where consistency of the files, performance, access control, traceability of modifications, and effective archiving are key requirements.

Soloviev, Igor [Univ. of California, Irvine, CA (U↗

Progress on an energy recovery linac upgrade to the Advanced Photon Source

The Advanced Photon Source (APS) is a third-generation storage-ring-based x-ray source that has been operating for more than 13 years and is enjoying a long period of stable, reliable operation. However, major accelerator upgrades are being investigated in order to maintain scientific relevance into the future. One very promising possibility is the use of an energy recovery linac (ERL). In this option, APS would transition from a source based on a stored electron beam to one based on a continuously generated high-brightness electron beam from a linac. Such a source promises dramatically improved brightness and transverse coherence compared to third-generation storage rings. We present a new design for an ERL upgrade that incorporates very long insertion devices. We show that operation at high electron beam energy provides the promise of extremely high brightness for hard x-rays. We also show results of the first start-to-end simulations of an ERL-based x-ray source.

43 PARTICLE ACCELERATORS↗

Resilient Entanglement Distribution in a Multihop Quantum Network

The evolution of quantum networking requires architectures capable of dynamically reconfigurable entanglement distribution to meet diverse user needs and ensure tolerance against transmission disruptions. We introduce multihop quantum networks to improve network reach and resilience by enabling quantum communications across intermediate nodes, thus broadening network connectivity and increasing scalability. We present multihop two-qubit polarization-entanglement distribution within a quantum network at the Oak Ridge National Laboratory campus. Our system uses wavelength-selective switches for adaptive bandwidth management on a software-defined quantum network that integrates a quantum data plane with classical data and control planes, creating a flexible, reconfigurable mesh. Our network distributes entanglement across six nodes within three subnetworks, each located in a separate building, optimizing quantum state fidelity and transmission rate through adaptive resource management. Additionally, we demonstrate the network's resilience by implementing a link recovery approach that monitors and reroutes quantum resources to maintain service continuity despite link failures—paving the way for scalable and reliable quantum networking infrastructures.

Alshowkan, Muneer [Oak Ridge National Laboratory (↗

Coordinated Control Strategy of a Battery Energy Storage System to Support a Wind Power Plant Providing Multi-Timescale Frequency Ancillary Services

With increasing penetrations of wind generation on electric grids, wind power plants (WPPs) are encouraged to provide frequency ancillary services (FAS); however, it is a challenge to ensure that variable wind generation can reliably provide these ancillary services. This paper proposes using a battery energy storage system (BESS) to ensure the WPPs' commitment to FAS. This method also focuses on reducing the BESS's size and extending its lifetime. In this paper, a state-machine-based coordinated control strategy is developed to utilize a BESS to support the obliged FAS of a WPP (including both primary and secondary frequency control). This method takes into account the operational constraints of the WPP (e.g., real-time reserve) and the BESS (e.g., state of charge [SOC], charge and discharge rate) to provide reliable FAS. Meanwhile, an adaptive SOC-feedback control is designed to maintain SOC at the optimal value as much as possible and thus reduce the size and extend the lifetime of the BESS. In conclusion, the effectiveness of the control strategy is validated with an innovative, multi-area, interconnected power system simulation platform that can mimic realistic power systems operation and control by simulating real-time economic dispatch, regulating reserve scheduling, multi-area automatic generation control, and generators' dynamic response.

25 ENERGY STORAGE↗

U.S. Department of Energy's Role in the Energy-Water Nexus

The Department of Energy Organization Act of 1977 (DOE 1977) combined the Federal Energy Administration, the Energy Research and Development Administration, the Federal Power Commission, the nuclear weapons program, and portions of energy-related programs from other Federal agencies into a single agency, the U.S. Department of Energy (DOE). DOE’s goal is to promote the development and use of reliable, clean, and affordable energy in an environmentally responsible manner, and to maintain a comprehensive, national, strategic energy plan.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Deep learning categorization of infrasound array data

Here we develop a deep learning-based infrasonic detection and categorization methodology that uses convolutional neural networks with self-attention layers to identify stationary and non-stationary signals in infrasound array processing results. Using features extracted from the coherence and direction-of-arrival information from beamforming at different infrasound arrays, our model more reliably detects signals compared with raw waveform data. Using three infrasound stations maintained as part of the International Monitoring System, we construct an analyst-reviewed data set for model training and evaluation. We construct models using a 4-category framework, a generalized noise vs non-noise detection scheme, and a signal-of-interest (SOI) categorization framework that merges short duration stationary and non-stationary categories into a single SOI category. We evaluate these models using a combination of k-fold cross-validation, comparison with an existing “state-of-the-art” detector, and a transportability analysis. Although results are mixed in distinguishing stationary and non-stationary short duration signals, f-scores for the noise vs non-noise and SOI analyses are consistently above 0.96, implying that deep learning-based infrasonic categorization is a highly accurate means of identifying signals-of-interest in infrasonic data records.

47 OTHER INSTRUMENTATION↗

Contributions to MoDELib SOFTWARE

The purpose of the current request is to enable LANL employees to contribute computer source code to the existing public repository of the MoDELib software package. This software implements discrete dislocation dynamics (DDD) and finite element (FEM) methods and is currently a vital component of an ongoing DR project at LANL, in collaboration with its original author and maintainer Giacomo Po. Contributions from LANL employees would aim to enhance the reliability, accuracy, and performance of MoDELib simulations using LANL's high performance computing platforms through bug fixes, algorithmic refinements, and parallelization.

Julian, Nicholas↗

The Los Angeles 100% Renewable Energy Study (LA100): Chapter 6. Renewable Energy Investments and Operations

The City of Los Angeles has set ambitious goals to transform its electricity supply, aiming to achieve a 100% renewable energy power system by 2045, along with aggressive electrification targets for buildings and vehicles. To reach these goals, and assess the implications for jobs, electricity rates, the environment, and environmental justice, the Los Angeles City Council passed a series of motions directing the Los Angeles Department of Water and Power (LADWP) to determine the technical feasibility and investment pathways of a 100% renewable energy portfolio standard. The Los Angeles 100% Renewable Energy Study (LA100) is a first-of-its-kind objective, rigorous, and science-based power systems analysis to determine what investments could be made to achieve these goals. The LA100 final report is presented as a collection of 12 chapters and an executive summary, each of which is available as an individual download. This chapter explores pathways to 100% renewable electricity, describing the types of generation resources added, their costs, and how the systems maintain sufficient resources to serve customer demand, including resource adequacy and transmission reliability.

100% Renewable↗

Coulomb Friction Damper

Standard hydraulic shock absorber modified to form coulomb (linear friction) damper. Device damps very small velocities and is well suited for use with large masses mounted on soft springs. Damping force is easily adjusted for different loads. Dampers are more reliable than fluid dampers and also more economical to build and to maintain.

Appleberry, W. T.↗

DEPEND - A design environment for prediction and evaluation of system dependability

The development of DEPEND, an integrated simulation environment for the design and dependability analysis of fault-tolerant systems, is described. DEPEND models both hardware and software components at a functional level, and allows automatic failure injection to assess system performance and reliability. It relieves the user of the work needed to inject failures, maintain statistics, and output reports. The automatic failure injection scheme is geared toward evaluating a system under high stress (workload) conditions. The failures that are injected can affect both hardware and software components. To illustrate the capability of the simulator, a distributed system which employs a prediction-based, dynamic load-balancing heuristic is evaluated. Experiments were conducted to determine the impact of failures on system performance and to identify the failures to which the system is especially susceptible.

Goswami, Kumar K.↗

SURPHEX (tm): New dry photopolymers for replication of surface relief diffractive optics

High efficiency, deep groove, surface relief Diffractive Optical Elements (DOE) with various optical functions can be recorded in a photoresist using conventional interferometric holographic and computer generated photolithographic recording techniques. While photoresist recording media are satisfactory for recording individual surface relief DOE, a reliable and precise method is needed to replicate these diffractive microstructures to maintain the high aspect ratio in each replicated DOE. The term 'high aspect ratio' means that the depth of a groove is substantially greater, i.e. 2, 3, or more times greater, than the width of the groove. A new family of dry photopolymers SURPHEX was developed recently at Du Pont to replicate such highly efficient, deep groove DOE's. SURPHEX photopolymers are being utilized in Du Pont's proprietary Dry Photopolymer Embossing (DPE) technology to replicate with very high degree of precision almost any type of surface relief DOE. Surfaces relief microstructures with width/depth aspect ratio of 1:20 (0.1 micron/2.0 micron) were faithfully replicated by DPE technology. Several types of plastic and glass/quartz optical substrates can be used for economical replication of DOE.

Shvartsman, Felix P.↗

Construction and Testing of Data Acquisition Components for the Hall A Compton Polarimeter

Nuclear physics experiments require accurate knowledge of the spin polarization of the electron beam delivered to the experimental halls. Hall A is upgrading its Compton polarimeter in support of the lab's 12 GeV beam energy upgrade. This project centered around the data acquisition (DAQ) system for the scattered-photon detection component of the polarimeter. The goal was to test whether the DAQ software and hardware are capable of capturing, recording, and processing electron helicity-dependent scattering rate asymmetry data at high rates, while maintaining appropriate accuracy. We created the necessary circuits, and are able to reliably extract asymmetries of between 0.5{\%} and 11.5{\%} to 0.2{\%}. We did this in a deadtime-free regime at rates between 100 KHz and 350 KHz. We currently are unable to measure the system deadtime after it becomes manifest at about 350 KHz. These tests support the use of a scaled version of this configuration.

Hill, Joshua↗

Resilient Information Architecture Platform for Smart Grid (RIAPS)

A number of emerging trends will substantially alter the operation and control of the electric grid over the next several decades. These trends include ensuring resiliency under severe weather events, increasing integration of renewable electricity generation, supporting changing electricity demand patterns, and the improving cost effectiveness of distributed energy resources. To address these challenges, the future “Smart Grid” management will need to transition from centralized to coordinated distributed control paradigm. Reliable operation of the Smart Grid depends on distributed intelligence realized through software applications that run on distributed computing devices attached to the power system to collect data and collaboratively manage resources. However, much of the existing software for Smart Grid-enabled devices is either proprietary or developed with custom solutions, which limits interoperability among the heterogeneous devices and hinders the ability to manage system-level reliability, security, and resiliency requirements. Additionally, this approach makes Smart Grid applications hard to maintain, evolve, verify, and replace; resulting in high development and deployment costs. Further development of the Smart Grid requires a reusable software base-layer to move from hard-coded functionality to a plug-and-play architecture capable of managing system-level objectives and constraints in addition to providing consistent common services across heterogeneous devices and applications. Vanderbilt University, in collaboration with North Carolina State University and Washington State University has developed a foundation ‘software platform’ for developing and deploying robust, reliable, effective and secure software applications for the Smart Grid. The Resilient Information Architecture Platform for the Smart Grid (RIAPS) provides core services for building effective and powerful smart grid applications. It offers unique services for real-time data dissemination, fault tolerance, and coordination across apps distributed over the network.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The power of simplification: Operator interface with the AP1000{sup R} during design-basis and beyond design-basis events

The AP1000{sup R} plant is an 1100-MWe pressurized water reactor with passive safety features and extensive plant simplifications that enhance construction, operation, maintenance, safety and cost. The passive safety features are designed to function without safety-grade support systems such as component cooling water, service water, compressed air or HVAC. The AP1000 passive safety features achieve and maintain safe shutdown in case of a design-basis accident for 72 hours without need for operator action, meeting the expectations provided in the European Utility Requirements and the Utility Requirement Document for passive plants. Limited operator actions may be required to maintain safe conditions in the spent fuel pool (SFP) via passive means. This safety approach therefore minimizes the reliance on operator action for accident mitigation, and this paper examines the operator interaction with the Human-System Interface (HSI) as the severity of an accident increases from an anticipated transient to a design basis accident and finally, to a beyond-design-basis event. The AP1000 Control Room design provides an extremely effective environment for addressing the first 72 hours of design-basis events and transients, providing ease of information dissemination and minimal reliance upon operator actions. Symptom-based procedures including Emergency Operating Procedures (EOPs), Abnormal Operating Procedures (AOPs) and Alarm Response Procedures (ARPs) are used to mitigate design basis transients and accidents. Use of the Computerized Procedure System (CPS) aids the operators during mitigation of the event. The CPS provides cues and direction to the operators as the event progresses. If the event becomes progressively worse or lasts longer than 72 hours, and depending upon the nature of failures that may have occurred, minimal operator actions may be required outside of the control room in areas that have been designed to be accessible using components that have been designed to be reliable in these conditions. The primary goal of any such actions is to maintain or refill the passive inventory available to cool the core, containment and spent fuel pool in the safety-related and seismically qualified Passive Containment Cooling Water Storage Tank (PCCWST). The seismically-qualified, ground-mounted Passive Containment Cooling Ancillary Water Storage Tank (PCCAWST) is also available for this function as appropriate. The primary effect of these actions would be to increase the coping time for the AP1000 during design basis events, as well as events such as those described above, from 72 hours without operator intervention to 7 days with minimal operator actions. These Operator actions necessary to protect the health and safety of the public are addressed in the Post-72 Hour procedures, as well as some EOPs, AOPs, ARPs and the Severe Accident Management Guidelines (SAMGs). Should the event continue to become more severe and plant conditions degrade further with indications of inadequate core cooling, the SAMGs provide guidance for strategies to address these hypothetical severe accident conditions. The AP1000 SAMG diagnoses and actions are prioritized to first utilize the AP1000 features that are expected to retain a damaged core inside the reactor vessel. Only one strategy is undertaken at any time. This strategy will be followed and its effectiveness evaluated before other strategies are undertaken. This is a key feature of both the symptom-oriented AP1000 EOPs and the AP1000 SAMGs which maximizes the probability of retaining a damaged core inside the reactor vessel and containment while minimizing the chances for confusion and human errors during implementation. The AP1000 SAMGs are simple and straight-forward and have been developed with considerable input from human factors and plant operations experts. Most importantly, and different from severe accident management strategies for other plants, the AP1000 SAMGs do not require diagnosis of the location of the core (i.e., whether reactor vessel failure has occurred). This is a fundamental consequence of the AP1000 In-Vessel Retention approach, which allows severe accident management to be based on fundamental principles (e.g. provide coolant as close as possible to the core) that do not change during a specific event. This eliminates the need for one of the more difficult diagnostic requirements, since reactor vessel failure does not directly relate to any measurable plant parameter, and differs from other designs in that an engineered failure of the pressure vessel' (e.g. core catcher) is never required. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modernizing NASA's Risk Classification System

NASA's risk classification system dates back to an era when every new NASA space mission was a one-of-a-kind build, and the only way to obtain reliability was as a by-product through a combination of reliability analyses, extensive and stringent quality requirements, and extensive testing. Originally, there were very limited commercial capabilities to develop systems to work reliably in space, so NASA considered its own homegrown approach the only recipe for success. This approach involved very detailed and prescriptive piece-part controls and no reliance on (and to some extent a rejection of) any type of commercial practices. Often risk was considered to be the lowest when NASA had the maximum amount of control and prescription, and the highest when commercial practices were largely employed, and these principles drove risk classification in the agency. Over time, however, commercial capabilities grew, and many products became standardized and commercialized, while the agency maintained its tried-and-true approach, paying little attention to the evolution of the commercial sector. In fact, the commercial sector was developing systems that have direct, proven reliability, established over time, while NASA still maintained the approach to ignore the reality of the commercialized aspects of standard products, label them as high risk, and attempt to change them to align with the agency's piece-part control practices. A table of mission classification vs lifetime for missions launched after 2000 indicates no correlation between lifetime and classification, with the few exceptions involving missions that have very limited objectives and no valid purpose to continue after they were met. This paper steps through some of the key historical elements in risk classification and NASA's overall approach to assurance, and presents some elements being brought forward to modernize the approach and take advantage of the growing capability in the commercial sector.

risk↗

Failing in place for low-serviceability storage infrastructure using high-parity GPU-based RAID.

In order to provide large quantities of high-reliability disk-based storage, it has become necessary to aggregate disks into fault-tolerant groups based on the RAID methodology. Most RAID levels do provide some fault tolerance, but there are certain classes of applications that require increased levels of fault tolerance within an array. Some of these applications include embedded systems in harsh environments that have a low level of serviceability, or uninhabited data centers servicing cloud computing. When describing RAID reliability, the Mean Time To Data Loss (MTTDL) calculations will often assume that the time to replace a failed disk is relatively low, or even negligible compared to rebuild time. For platforms that are in remote areas collecting and processing data, it may be impossible to access the system to perform system maintenance for long periods. A disk may fail early in a platform's life, but not be replaceable for much longer than typical for RAID arrays. Service periods may be scheduled at intervals on the order of months, or the platform may not be serviced until the end of a mission in progress. Further, this platform may be subject to extreme conditions that can accelerate wear and tear on a disk, requiring even more protection from failures. We have created a high parity RAID implementation that uses a Graphics Processing Unit (GPU) to compute more than two blocks of parity information per stripe, allowing extra parity to eliminate or reduce the requirement for rebuilding data between service periods. While this type of controller is highly effective for RAID 6 systems, an important benefit is the ability to incorporate more parity into a RAID storage system. Such RAID levels, as yet unnamed, can tolerate the failure of three or more disks (depending on configuration) without data loss. While this RAID system certainly has applications in embedded systems running applications in the field, similar benefits can be obtained for servers that are engineered for storage density, with less regard for serviceability or maintainability. A storage brick can be designed to have a MTTDL that extends well beyond the useful lifetime of the hardware used, allowing the disk subsystem to require less service throughout the lifetime of a compute resource. This approach is similar to the Xiotech ISE. Such a design can be deliberately placed remotely (without frequent support) in order to provide colocation, or meet cost goals. For workloads where reliability is key, but conditions are sub-optimal for routine serviceability, a high-parity RAID can provide extra reliability in extraordinary situations. For example, for installations requiring very high Mean Time To Repair, the extra parity can eliminate certain problems with maintaining hot spares, increasing overall reliability. Furthermore, in situations where disk reliability is reduced because of harsh conditions, extra parity can guard against early data loss due to lowered Mean Time To Failure. If used through an iSCSI interface with a streaming workload, it is possible to gain all of these benefits without impacting performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗