Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reliability Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

An Approach to Automate tools for the Risk Assessment of Digital Instrumentation and Control Systems

Reliable digital instrumentation and control systems (DI&C) are integral for sustaining the continued operation of nuclear power plants. These systems ensure that nuclear reactors operate safely, efficiently, and within regulatory requirements. Yet, the cost of designing and licensing new nuclear DI&C can be prohibitively expensive. Under the U.S. Department of Energy Light Water Reactor Sustainability Program, Idaho National Laboratory has developed a framework for supporting the risk-informed design of DI&C systems by offering methods to support the identification, quantification, and evaluation of risks for various DI&C design architectures. The framework indicates potential software failure modes and provides pathways for quantifying the potential for these software failures, including common cause failures. Using the framework’s systematic approach, challenges for assessing risks within new and existing nuclear DI&C systems can be reduced. Nevertheless, the current framework can be further improved using the convenience of automation. This paper introduces the development of Software for the Hazard Identification and Evaluation of Digital Systems (SHIELDS). SHIELDS is an engineering software package that enables the identification, elimination, and mitigation of potential risks and reduces the burden of deploying reliable DI&C systems. This work introduces plans and techniques to digitize and improve the manual risk assessment modules of the framework. These improvements will save time and increase the repeatability and usability of the framework, making it more accessible to a wider range of users. Ultimately, this introduces SHIELDS and how its modules support efficient development of safe and reliable DI&C systems.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Oro-Nasal Mask Versus Two-Way Non-Rebreathing Valves for Maximal Aerobic Capacity Testing in Astronauts

Astronauts complete maximal aerobic capacity (VO2pk) testing as part of their annual fitness assessment (AFA) as well as several times once assigned to an International Space Station mission. Historically, the 2-Way T-Shape Non-Rebreathing valve with a mouthpiece and nose clip (“Mouthpiece”) has been used in these tests. The testing procedure was updated to use the oro-nasal mask (“Mask”) for the AFA starting in June 2017. Astronauts who used the mask during their AFA requested it be certified to be used for all mission associated tests. Considering the criticality of the data and the schedule constraints of astronauts, it is imperative that the requested hardware change provide data with equivalent reliability and repeatability as provided by the mouthpiece. PURPOSE: To assess the reliability and validity of mask vs. mouthpiece by comparing submaximal and VO2pkdata within subjects (approximately 1 year apart). METHODS: Each of 17 active astronauts completed a VO (sub 2pk) test with the mouthpiece (first) and the mask (second) for their AFA. The VO (sub 2pk) test was conducted on a cycle ergometer with a metabolic cart. The nominal protocol started with a 3-minute warm-up at 50 Watts (W) and increased 25W every minute until volitional fatigue (Light: 45W start; 15W increase). The VO (sub 2pk)s were compared between tests and the expected day-to-day variation (plus or minus 5 percent) was used as the threshold for determining agreement between tests. Submaximal values were plotted and evaluated visually for deviations between mask and mouthpiece. RESULTS: VO (sub 2pk) values were more than 5 percent different, despite similar test times, between mouthpiece and mask in 6 of 17 comparisons, 3 of which were higher with the mask (9.0 plus or minus 5.9 percent) while 3 were lower (minus10.8 plus or minus 2.0 percent) with the mask. The submaximal data did not indicate a leak in either apparatus during these tests. An Astronaut Strength & Conditioning Rehabilitation specialist confirmed that the measured differences in VO (sub 2pk) of these 6 astronauts was consistent with observed changes in exercise habits during the year that separated the two tests. CONCLUSION: After being presented with the results of this data mining effort the mask was accepted for use in all tests, excepting that, if a leak is detected without resolve, the test will be repeated (if schedule allows) and remaining tests will be completed with the mouthpiece.

Buxton, R.↗

India Power Sector Reliability Analysis [Slides]

The objective of the study is to assess pathways for India to achieve its 2070 power sector goals reliably and cost-effectively by considering various supply- and demand-side factors to support planning by national stakeholders including the Central Electricity Authority (CEA).

08 HYDROGEN↗

An Empirical Study on Ultrasonic Testing in Lieu of Radiography for Nuclear Power Plants

Research is being conducted for the U.S. Nuclear Regulatory Commission (NRC) at the Pacific Northwest National Laboratory (PNNL) to assess the capability, effectiveness, and reliability of ultrasonic testing (UT) as a replacement method for radiographic testing (RT) for inspecting nuclear power plant (NPP) components. A primary objective of this work is to evaluate UT techniques to assess their ability to detect, locate, size, and characterize fabrication flaws in typical NPP weldments. This particular study focused on the evaluation of four carbon steel pipe-to-pipe welds on specimens that ranged in thicknesses from 19.05 mm (0.75 in.) to 27.8 mm (1.094 in.) and were 355.6 mm (14.0 in.) or 406.4 mm (16.0 in.) in diameter. The pipe welds contained both implanted (intentional) fabrication flaws as well as bonus (unintentional) flaws throughout the entire thickness of the weld and the adjacent base material. The fabrication flaws were a combination of planar and volumetric flaw types, including incomplete fusion, incomplete penetration, cracks, porosity, and slag inclusions. The examinations were conducted using phased-array UT (PA UT) techniques applied primarily for detection and length sizing of the flaws. Radiographic examinations were also conducted on the specimens with RT detection and length sizing results being used to establish true state. This paper will discuss the comparison of UT and RT (true state) detection results conducted to date along with a discussion on the technical gaps that need to be addressed before these methods can be used interchangeably for repair and replacement activities for NPP components.

NDE reliability↗

CBGA/PBGA Package Planarity and Assembly Reliability

Jet Propulsion Laboratory (JPL) is currently assessing the use of Ball Grid Arrays (BGAs) for National Aeronautics and Space Administration (NASA) spaceflight applications. This work is being funded through NASA Headquarters, Code Q. The objectives are to demonstrate the robustness, quality and reliability of BGAs technology, and to assist in the development of the repidly growing infastructure for this technology.

BGAs ball grid arrays test vehicles plastic and ce↗

Advanced SAPHIRE 8 Modeling Methods for Probabilistic Risk Assessment via the Systems Analysis Program for Hands-On Integrated Reliability Evaluations (SAPHIRE) Software P-202

1.1. Overview of the Advanced SAPHIRE Material The Advanced SAPHIRE course material is intended to both (1) provide guidance for learning advanced SAPHIRE features during the class and (2) become a stand-alone reference document after finishing the class. Thus, the format for the class material is a combination of the traditional “overhead-type” of presentation information with a structured, reference-type document. Major topics that are covered in the Advanced SAPHIRE class include: Advanced data base concepts such as Model Type (e.g., random, seismic, fire, flood). Definition of house events and how they are used on a sequence-by-sequence basis to manipulate individual fault tree logic using sequence flag sets or fault tree flag sets. ? Basic event templates, compound basic event equation editors, and human error worksheets. A rule-based event tree top event substitution feature (called the Link Event Tree Rule Editor) which allows for top event substitutions. A rule-based cut set post-processing feature (called the Recovery Rules) which allows cut set manipulation. Cut set analysis based upon rule-based end state categories (called End State Analysis). Cut set generation options for both fault trees and event tree sequences. The large event tree methodology and how SAPHIRE can be used to generate sequence cut sets for this method. The transfer of data between SAPHIRE data bases and between other PRA codes (MAR-D).

97 MATHEMATICS AND COMPUTING↗

Design and requirements of a hydrogen component reliability database (HyCReD)

Hydrogen technologies are expected to play a key role in the decarbonization of several sectors including energy storage and transportation. Rigorous investigation and quantification of the risk and reliability issues associated with hydrogen technologies will be critical to ensuring both their wider adoption and safe, economical operations. Quantitative risk assessment (QRA) is an important tool that has been used to enable the safe deployment of many engineering systems, including hydrogen fueling stations and hydrogen storage systems. However, QRA studies require reliability data which is currently lacking for expanding applications of hydrogen systems. Here, to address this gap, we present a new structure for a hydrogen component reliability database (HyCReD) that can be used to generate reliability data to be used in QRA, reliability, safety studies, maintenance planning, and more. Building on our previous work examining four major hydrogen safety data collection tools (West et al., 2022) [1], our approach in this work was to consult scientific literature on reliability data collection as well as a number of existing reliability engineering databases in the oil & gas, chemical processing, and nuclear power plant sectors. The evaluation of these databases led to identifying best practices to be implemented in a data collection framework for a hydrogen component reliability database. Based on these best practices, a set of 24 requirements for the proposed database are presented, covering its characteristics and the types of data to be collected. We define the structure of the HyCReD database and 25 data elements to be collected, spanning system description, failure, shutdown, or near-miss events, and maintenance events. The data elements are then defined according to international standards used in the safety and reliability practice and potential choice lists are provided for each field. Since this database is being piloted for hydrogen fueling stations, a generic station component hierarchy developed by West (2021) [2] is used to standardize system data. Finally, we demonstrate populating the database with information extracted from five narrative reports on hydrogen fueling station incidents.

08 HYDROGEN↗

The NPOESS Preparatory Project Science Data Segment: Brief Overview

The NPOESS Preparatory Project (NPP) provides remotely-sensed land, ocean, atmospheric, ozone, and sounder data that will serve the meteorological and global climate change scientific communities while also providing risk reduction for the National Polar-orbiting Operational Environmental Satellite System (NPOESS), the U.S. Government s future low-Earth orbiting satellite system monitoring global weather and environmental conditions. NPOESS and NPP are a new era, not only because the sensors will provide unprecedented quality and volume of data but also because it is a joint mission of three federal agencies, NASA, NOAA, and DoD. NASA's primary science role in NPP is to independently assess the quality of the NPP science and environmental data records. Such assessment is critical for making NPOESS products the best that they can be for operational use and ultimately for climate studies. The Science Data Segment (SDS) supports science assessment by assuring the timely provision of NPP data to NASA s science teams organized by climate measurement themes. The SDS breaks down into nine major elements, an input element that receives data from the operational agencies and acts as a buffer, a calibration analysis element, five elements devoted to measurement based quality assessment, an element used to test algorithmic improvements, and an element that provides overall science direction. This paper will describe how the NPP SDS will leverage on NASA experience to provide a mission-reliable research capability for science assessment of NPP derived measurements.

Schweiss, Robert J.↗

Tissue-specific in vivo genetic toxicity of nine polycyclic aromatic hydrocarbons assessed using the Muta™Mouse transgenic rodent assay

Test batteries to screen chemicals for mutagenic hazard include several endpoints regarded as effective for detecting genotoxic carcinogens. Traditional in vivo methods primarily examine clastogenic endpoints in haematopoietic tissues. Although this approach is effective for identifying systemically distributed clastogens, some mutagens may not induce clastogenic effects; moreover, genotoxic effects may be restricted to the site of contact and/or related tissues. An OECD test guideline for transgenic rodent (TGR) gene mutation assays was released in 2011, and the TGR assays permit assessment of mutagenicity in any tissue. This study assessed the responses of two genotoxicity endpoints following sub-chronic oral exposures of male Muta™Mouse to 9 carcinogenic polycyclic aromatic hydrocarbons (PAHs). Clastogenicity was assessed via induction of micronuclei in peripheral blood, and mutagenicity via induction of lacZ transgene mutations in bone marrow, glandular stomach, small intestine, liver, and lung. Additionally, the presence of bulky PAH-DNA adducts was examined. Five of the 9 PAHs elicited positive results across all endpoints in at least one tissue, and no PAHs were negative or equivocal across all endpoints. All PAHs were positive for lacZ mutations in at least one tissue (sensitivity = 100%), and for 8 PAHs, one or more initial sites of chemical contact (i.e., glandular stomach, liver, small intestine) yielded a greater response than bone marrow. Five PAHs were positive in the micronucleus assay (sensitivity = 56%). Furthermore, all PAHs produced DNA adducts in at least one tissue. The results demonstrate the utility of the TGR assay for mutagenicity assessment, especially for compounds that may not be systemically distributed. - Highlights: • The Muta™Mouse is a reliable tool for in vivo mutagenicity assessment of PAHs. • All 9 PAHs induced lacZ transgene mutations in small intestine. • Only 5 of 9 PAHs induced lacZ mutations and micronuclei in haematopoietic tissue. • Tissue-specific results are likely related to metabolism, repair, and proliferation. • For oral exposures, it is important to examine effects at the site-of-contact.

60 APPLIED LIFE SCIENCES↗

Modeling & Analysis of a Small Hydropower Plant and Battery Energy Storage System Connected as a Microgrid

Puget Sound Energy (PSE) is a utility with headquarters in Bellevue, WA that provides electric and gas service to customers in many regions of western Washington State. PSE is undertaking the implementation of a battery energy storage system pilot project in Glacier, WA, a small town located in the North Cascade Mountains near Mt. Baker Ski Area. Glacier experiences power outages that are both somewhat frequent and lengthy (roughly 2.8 outages per year with a duration of 7.5 hours average). The primary cause of the outages is faults on a long 55 kV transmission line that serves the town of Glacier from the Kendall substation. This approximately 10-mile long line is shown in the upper left of Figure 1 below. The Kendall-Glacier transmission line extends through an area of heavy forest with few reasonable options for increasing the line’s reliability. The substation in Glacier (also shown on figure below) serves over 1000 customers that are mostly residential but includes over 50 small businesses. The town has approximately 250 year-round residents, and a peak in visitors during the winter ski season when storms are also more likely to cause power outages. Figure 1: Proposed Microgrid in Glacier, WA Given the reliability challenges in Glacier, PSE is assessing the feasibility of a 2MW/4.4MWh battery energy storage system (BESS) that would allow for improved reliability. The BESS would also allow for the ability to investigate other applications for utility-scale energy 5 storage. This energy storage system is being considered for operation in “planned islanding” and “microgrid” mode. “Planned islanding” indicates use of the BESS to provide power to part or potentially all of the load in the town of Glacier during an outage. “Microgrid” indicates utilization (during an outage) of the BESS in parallel with Nooksack Falls Hydroelectric Power Plant, a small (nameplate 1.5 MW/2000 HP) hydro power plant less than 10 miles from the town of Glacier. Nooksack is a run-of river small hydro generation plant with a gross head of 226 ft. The site has a 5-foot diameter penstock which enters the powerhouse and goes into a pelton turbine with six runners on one shaft. It was originally constructed by Stone & Webster in 1906, which makes it the second oldest operating power generation facility in Western Washington. It was placed on the National Register of Historic places in December of 1988. The plant operated until 1997 when a fire destroyed the generator. The project continued operations in 2003 after the replacement of the generator and other updates.

13 HYDRO ENERGY↗

Day-to-day reliability of basal heart rate and short-term and ultra short-term heart rate variability assessment by the Equivital eq02+ LifeMonitor in US Army soldiers

Introduction The present study determined the (1) day-to-day reliability of basal heart rate (HR) and HR variability (HRV) measured by the Equivital eq02+ LifeMonitor and (2) agreement of ultra short-term HRV compared with short-term HRV. Methods Twenty-three active-duty US Army Soldiers (5 females, 18 males) completed two experimental visits separated by >48 hours with restrictions consistent with basal monitoring (eg, exercise, dietary), with measurements after supine rest at minutes 20–21 (ultra short-term) and minutes 20–25 (short-term). HRV was assessed as the SD of R–R intervals (SDNN) and the square root of the mean squared differences between consecutive R–R intervals (RMSSD). Results The day-to-day reliability (intraclass correlation coefficient (ICC)) using linear-mixed model approach was good for HR (0.849, 95% CI: 0.689 to 0.933) and RMSSD (ICC: 0.823, 95% CI: 0.623 to 0.920). SDNN had moderate day-to-day reliability with greater variation (ICC: 0.689, 95% CI: 0.428 to 0.858). The reliability of RMSSD was slightly improved when considering the effect of respiration (ICC: 0.821, 95% CI: 0.672 to 0.944). There was no bias for HR measured for 1 min versus 5 min (p=0.511). For 1 min measurements versus 5 min, there was a very modest mean bias of −4 ms for SDNN and −1 ms for RMSSD (p≤0.023). Conclusion When preceded by a 20 min stabilisation period using restrictions consistent with basal monitoring and measuring respiration, military personnel can rely on the eq02+ for basal HR and RMSSD monitoring but should be more cautious using SDNN. These data also support using ultra short-term measurements when following these procedures.

General & Internal Medicine↗

Micro-beam Laue alignment of multi-reflection Bragg coherent diffraction imaging measurements

Multi-reflection Bragg coherent diffraction imaging has the potential to allow three-dimensional (3D) resolved measurements of the full lattice strain tensor in specific micro-crystals. Until now such measurements were hampered by the need for laborious, time-intensive alignment procedures. Here, in this paper, a different approach is demonstrated, using micro-beam Laue X-ray diffraction to first determine the lattice orientation of the micro-crystal. This information is then used to rapidly align coherent diffraction measurements of three or more reflections from the crystal. Based on these, 3D strain and stress fields in the crystal are successfully determined. This approach is demonstrated on a focused ion beam milled micro-crystal from which six reflections could be measured. Since information from more than three independent reflections is available, the reliability of the phases retrieved from the coherent diffraction data can be assessed. Lastly, our results show that rapid, reliable 3D coherent diffraction measurements of the full lattice strain tensor in specific micro-crystals are now feasible and can be successfully carried out even in heavily distorted samples.

36 MATERIALS SCIENCE↗

An overview of reliability methods in mechanical and structural design

An evaluation is made of modern methods of fast probability integration and Monte Carlo treatment for the assessment of structural systems' and components' reliability. Fast probability integration methods are noted to be more efficient than Monte Carlo ones. This is judged to be an important consideration when several point probability estimates must be made in order to construct a distribution function. An example illustrating the relative efficiency of the various methods is included.

Wirsching, P. H.↗

Environmental DNA as a tool for hydropower impact assessments: current status, special considerations, and future integration

Globally there is an urgent need to find sustainable solutions to balance energy production with the protection of vulnerable species and conservation of biodiversity. This is particularly critical for freshwater ecosystems, habitats, and species that may be impacted by hydropower development and operations needed to meet energy grid demands. Reliable and accurate environmental impact assessments (EIAs) that identify the biological, physical, or social impacts of hydropower are key to ensure biodiversity, ecosystem, and societal sustainability. The analysis of environmental DNA (eDNA) has the potential to transform hydropower EIAs, management and mitigation planning, and decision-making procedures. Further, the incorporation of eDNA surveys into EIAs during both hydropower planning and continued operations may streamline regulatory processes by improving our understanding of potentially impacted biota and habitats and evaluating environmental impacts mitigation. Here, we: (i) highlight current understanding and use of eDNA in freshwater environments; (ii) examine critical considerations for eDNA integration into hydropower EIAs and biological monitoring; (iii) identify knowledge gaps in eDNA analysis and applications unique to hydropower-regulated systems; and (iv) discuss future opportunities to bolster the incorporation of eDNA into hydropower research including regulatory acceptance and public engagement. While we acknowledge that there are several factors that may complicate the broad adoption of eDNA as a tool for assessing the impacts of hydropower, we anticipate that growing confidence in eDNA through hydropower-specific protocols, calibrations, and validations will overcome these inherent uncertainties.

aquatic biodiversity↗

Issues in Benchmarking Human Reliability Analysis Methods: A Literature Review

There is a diversity of human reliability analysis (HRA) methods available for use in assessing human performance within probabilistic risk assessments (PRA). Due to the significant differences in the methods, including the scope, approach, and underlying models, there is a need for an empirical comparison investigating the validity and reliability of the methods. To accomplish this empirical comparison, a benchmarking study comparing and evaluating HRA methods in assessing operator performance in simulator experiments is currently underway. In order to account for as many effects as possible in the construction of this benchmarking study, a literature review was conducted, reviewing past benchmarking studies in the areas of psychology and risk assessment. A number of lessons learned through these studies are presented in order to aid in the design of future HRA benchmarking endeavors.

99 GENERAL AND MISCELLANEOUS↗

Optical Spectroscopy Approach for the Predictive Assessment of Kidney Functional Recovery Following Ischemic Injury

Tissue that has undergone significant yet unknown amount of ischemic injury is frequently encountered in organ transplantation and trauma clinics. With no reliable real-time method of assessing the degree of injury incurred in tissue, surgeons generally rely on visual observation which is subjective. In this work, we investigate the use of optical spectroscopy methods as a potentially more reliable approach. Previous work by various groups was strongly suggestive that tissue autofluorescence from NADH obtained under UV excitation is sensitive to metabolic response changes. To test and expand upon this concept, we monitored autofluorescence and light scattering intensities of injured vs. uninjured rat kidneys via multimodal imaging under 355 nm, 325 nm, and 266 nm excitation as well as scattering under 500 nm illumination. 355 nm excitation was used to probe mainly NADH, a metabolite, while 266 nm excitation was used to probe mainly tryptophan to correct for non-metabolic signal artifacts. The ratio of autofluorescence intensities derived under these two excitation wavelengths was calculated and its temporal profile was fit to a relaxation model. Time constants were extracted, and longer time constants were associated with kidney dysfunction. Analysis of both the autofluorescence and light scattering images suggests that changes in microstructure tissue morphology, blood absorption spectral characteristics, and pH contribute to the behavior of the observed signal which may be used to obtain tissue functional information and offer predictive capability.

59 BASIC BIOLOGICAL SCIENCES↗

GSFC Risk Assessment Process for Inherited Items

The NASA Goddard Space Flight Center Safety and Mission Assurance Directorate is implementing an alternate process for approval of Spacecraft Inherited Items in accordance with Goddard Procedural Requirements 8730.5. A Commodity Risk Assessment Engineer is performing an Inherited Item Risk Assessment (I2RA) for the use of Spacecraft Standard Components (items generally necessary to control the spacecraft, e.g. reaction wheel assemblies) and payload flight spares or Built-to-Print items. The I2RA may take into account prior space flight performance, criticality of the component, qualification records, quality and reliability records, storage conditions, manufacturer assessments, and mission specific parameters like mission environment and duration. The I2RA provides a means to accept for the entire item materials, parts or workmanship non-conformances, that do not significantly increase risk.

Risk Assessment↗