Search NASA⌕ Search

SEARCH · Search NASA

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

A laboratory verification sensor

The use of a variant of the Hartmann test is described to sense the coalignment of the 36 primary mirror segments of the Keck 10-meter Telescope. The Shack-Hartmann alignment camera is a surface-tilt-error-sensing device, operable with high sensitivity over a wide range of tilt errors. An interferometer, on the other hand, is a surface-height-error-sensing device. In general, if the surface height error exceeds a few wavelengths of the incident illumination, an interferogram is difficult to interpret and loses utility. The Shack-Hartmann aligment camera is, therefore, likely to be attractive as a development tool for segmented mirror telescopes, particularly at early stages of development in which the surface quality of developmental segments may be too poor to justify interferometric testing. The constraints are examined which would define the first-order properties of a Shack-Hartmann alignment camera and the precision and range of measurement one could expect to achieve with it are investigated. Fundamental constraints do arise, however, from consideration of geometrical imaging, diffraction, and the density of sampling of images at the detector array. Geometrical imagining determines the linear size of the image, and depends on the primary mirror diameter and the f-number of a lenslet. Diffraction is another constraint; it depends on the lenslet aperture. Finally, the sampling density at the detector array is important since the number of pixels in the image determines how accurately the centroid of the image can be measured. When these factors are considered under realistic assumptions it is apparent that the first order design of a Shack-Hartmann alignment camera is completely determined by the first-order constraints considered, and that in the case of a 20-meter telescope with seeing-limited imaging, such a camera, used with a suitable detector array, will achieve useful precision.

Vaughan, Arthur H.↗

Martian Atmospheric Dust Mitigation for ISRU Intakes via Electrostatic Precipitation

The Mars 2020 and Mars Sample Return missions expected to fly to Mars within the next ten years will each include an In Situ Resource Utilization (ISRU) system. They convert carbon dioxide in the Martian atmosphere into consumable oxygen at 1% and 20% of the rate required by a full scale human exploration Mars mission, respectively. The ISRU systems will need to draw in the surrounding atmosphere at a rate of 110L/min and 550L/min, respectively, in order to meet their oxygen production goals. Over the duration of each respective mission, a total atmospheric dust mass of 4.86g and 243g will be drawn into each system, respectively. Ingestion of large quantities of dust may interfere with ISRU operations, so a dust mitigation device will be required. The atmospheric volume and dust mass flow rates above will be utilized to simulate Martian environmental conditions in a laboratory electrostatic precipitator being developed to provide active dust mitigation support for atmospheric ISRU systems such as these.

In-situ resource utilization↗

Development of practical high temperature superconducting wire for electric power application

The technology of high temperature superconductivity has gone from beyond mere scientific curiousity into the manufacturing environment. Single lengths of multifilamentary wire are now produced that are over 200 meters long and that carry over 13 amperes at 77 K. Short-sample critical current densities approach 5 x 104 A/sq cm at 77 K. Conductor requirements such as high critical current density in a magnetic field, strain-tolerant sheathing materials, and other engineering properties are addressed. A new process for fabricating round BSCCO-2212 wire has produced wires with critical current densities as high as 165,000 A/sq cm at 4.2 K and 53,000 A/sq cm at 40 K. This process eliminates the costly, multiple pressing and rolling steps that are commonly used to develop texture in the wires. New multifilamentary wires with strengthened sheathing materials have shown improved yield strengths up to a factor of five better than those made with pure silver. Many electric power devices require the wire to be formed into coils for production of strong magnetic fields. Requirements for coils and magnets for electric power applications are described.

Hawsey, Robert A.↗

Thrust Measurement of Dielectric Barrier Discharge (DBD) Plasma Actuators: New Anti-Thrust Hypothesis, Frequency Sweeps Methodology, Humidity and Enclosure Effects

We discuss thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators devices used for aerodynamic active flow control. After a review of our experience with conventional thrust measurement and significant non-repeatability of the results, we devised a suspended actuator test setup, and now present a methodology of thrust measurements with decreased uncertainty. The methodology consists of frequency scans at constant voltages. The procedure consists of increasing the frequency in a step-wise fashion from several Hz to the maximum frequency of several kHz, followed by frequency decrease back down to the start frequency of several Hz. This sequence is performed first at the highest voltage of interest, then repeated at lower voltages. The data in the descending frequency direction is more consistent and selected for reporting. Sample results show strong dependence of thrust on humidity which also affects the consistency and fluctuations of the measurements. We also observed negative values of thrust, or "anti-thrust", at low frequencies between 4 Hz and up to 64 Hz. The anti-thrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic anti-thrust curve are correlated with appearance of visible plasma discharges. We propose the anti-thrust hypothesis. It states that the measured thrust is a sum of plasma thrust and anti-thrust, and assumes that the anti-thrust exists at all frequencies and voltages. The anti-thrust depends on actuator geometry and materials and on the test installation. It enables the separation of the plasma thrust from the measured total thrust. This approach enables more meaningful comparisons between actuators at different installations and laboratories. The dependence on test installation was validated by surrounding the actuator with a grounded large-diameter metal sleeve. Strong dependence on humidity is also shown; the thrust significantly increased with decreasing humidity, e.g., 44 percent increase as relative humidity changed from 18 percent and dew point 33 degF to 50 percent and dew point of 57 degF.

Ashpis, David E.↗

Dielectric Barrier Discharge (DBD) Plasma Actuators Thrust-Measurement Methodology Incorporating New Anti-Thrust Hypothesis

We discuss thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators devices used for aerodynamic active flow control. After a review of our experience with conventional thrust measurement and significant non-repeatability of the results, we devised a suspended actuator test setup, and now present a methodology of thrust measurements with decreased uncertainty. The methodology consists of frequency scans at constant voltages. The procedure consists of increasing the frequency in a step-wise fashion from several Hz to the maximum frequency of several kHz, followed by frequency decrease back down to the start frequency of several Hz. This sequence is performed first at the highest voltage of interest, then repeated at lower voltages. The data in the descending frequency direction is more consistent and selected for reporting. Sample results show strong dependence of thrust on humidity which also affects the consistency and fluctuations of the measurements. We also observed negative values of thrust or "anti-thrust", at low frequencies between 4 Hz and up to 64 Hz. The anti-thrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic anti-thrust curve are correlated with appearance of visible plasma discharges. We propose the anti-thrust hypothesis. It states that the measured thrust is a sum of plasma thrust and anti-thrust, and assumes that the anti-thrust exists at all frequencies and voltages. The anti-thrust depends on actuator geometry and materials and on the test installation. It enables the separation of the plasma thrust from the measured total thrust. This approach enables more meaningful comparisons between actuators at different installations and laboratories. The dependence on test installation was validated by surrounding the actuator with a large diameter, grounded, metal sleeve.

Ashpis, David E.↗

Characteristics of the SIR-A system and images

Sample images obtained with the Shuttle Imaging Radar A (SIR-A) are presented, along with design and performance features of the SIR-A, Seasat and Landsat images of the same scenes for comparison purposes. The SIR-A functions at the L-band 25 cm at a frequency of 1278 GHz with a spectral bandwidth of 6 MHz. The images were taken at an angle of 47 deg and furnished a resolution of 40 m from an altitude of 259 km. The images covered a ground swath 50 km wide. The images are provided to assist in the development of effective techniques for interpreting radar imagery. The SIR-A instrument is a precursor of another imaging device which will be flown around Venus. The images provided include sections of France, Sardinia and Algeria.

Rebillard, PH.↗

Mars 94 Mission: Current plans and science

The Soviet Space Program proposes large-scale investigations of Mars as one of the most important trends for the next 10 to 15 years. The objectives include global studies of the surface of Mars, its atmosphere, and the return of soil samples to Earth. The first stage of the program is to be implemented in the mid-90s. It includes measurements from an orbiter and a balloon in the atmosphere and on the surface from a rover as well. This can be done using the high energy upper stage of the launch vehicle. The payload mass could amount to about 1500 to 1700 kg. The capabilities of the Mars Mission in 1994 are discussed. As presently planned, Mars will be studied concurrently with the following facilities: an orbiter with instruments for remote sensing from a polar orbit; a balloon deployed in the Martian atmosphere; a rover on the surface; a network of smaller stations on the surface; a subsatellite; and a device to return a container with photo films of the Martian surface taken with a super high resolution. If the exploration of Mars with the MARS-94 spacecraft begins late in 1994 the American Mars-Observer will still be functioning in the near-Mars orbit. Thus, joint operation of the two satellites becomes possible providing coordinated exploration, the creation of joint data banks, joint data interpretation, and the development of a joint engineering model of Mars for its further exploration. There is an opportunity for experiments and instrumentation on the Soviet missions that address questions of interest to exobiology. American scientists are invited to participate in the upcoming Soviet missions, and lend expertise to further understanding of the relationship between the physical and chemical evolution of the solar system and the appearance of life.

Mukhin, Lev↗

Stable isotope analysis of molecular oxygen from silicates and oxides using CO2 laser extraction

A laser-excited system for determination of the oxygen isotope composition of small quantities of silicate and oxide minerals was constructed and tested at JSC. This device is the first reported to use a commercially available helium cryostat to transfer and purify oxygen gas quantitatively within the system. The system uses oxygen gas instead of the conventional CO2 for mass spectrometer analyses. This modification of technique permits determination of all three stable oxygen isotopes, an essential requirement for oxygen isotope analysis of meteoritic material. Tests of the system included analysis of standard silicate materials NBS 28 and UWMG2 garnet, six SNC meteorites, and inclusions and chondrules from the Allende meteorite. Calibration with terrestrial standards was excellent. Meteorite values are close to published values and show no evidence of terrestrial oxygen contamination. The one limitation observed is that, in some runs on fine-grained SNC matrix material, sample results were affected by other samples in the sample holder within the reaction chamber. This reemphasizes the need for special precautions in dealing with fine-grained, reactive samples. Performance of the JSC instrument compares favorably with that of any other instrument currently producing published oxygen isotope data.

Perry, Eugene↗

Detection of Fatigue Cracks at Rivets with Self-Nulling Probe

A new eddy current probe developed at NASA Langley Research Center has been used to detect small cracks at rivets in aircraft lap splices [1]. The device has earlier been used to detect isolated fatigue cracks with a minimum detectable flaw size of roughly 1/2 to 1/3 the diameter of the probe [2]. The present work shows that the detectable flaw size for cracks originating at rivets can be greatly improved upon from that of isolated flaws. The use of a rotating probe method combined with spatial filtering has been used to detect 0.18 cm EDM notches, as measured from the rivet shank, with a 1.27 cm diameter probe and to detect flaws buried under the rivet head, down to a length of 0.076 cm, using a 0.32 cm diameter probe. The Self-Nulling Electromagnetic Flaw Detector induces a high density eddy current ring in the sample under test. A ferromagnetic flux focusing lens is incorporated such that in the absence of any inhomogeneities in the material under test only a minimal magnetic field will reach the interior of the probe. A magnetometer (pickup coil) located in the center of the probe therefore registers a null voltage in the absence of material defects. When a fatigue crack or other discontinuity is present in the test article the path of the eddy currents in the material is changed. The magnetic field associated with these eddy currents then enter into the interior of the probe, producing a large output voltage across the pickup coil leads. Further

Wincheski, Buzz↗

Wide field imaging of solar system objects with an 8192 x 8192 CCD mosaic

As part of this program, we successfully completed the construction of the world's largest CCD camera, an 8192 x 8192 CCD mosaic. The system employs 8 2K x 4K 3-edge buttable CCDs arranged in a 2 x 4 chip mosaic. The focal plane has small gaps (less than 1 mm) between mosaic elements and measures over 120 mm x 120 mm. The initial set of frontside illuminated CCDs were developed with Loral-Fairchild in a custom foundry run. The initial lots yielded of order 20 to 25 functional devices, of which we selected the best eight for inclusion for the camera. We have designed a custom 3-edge-buttable package that ensures the CCD dies are mounted flat to plus or minus 10 microns over the entire area of the mosaic. The mosaic camera system consists of eight separate readout signal chains controlled by two independent DSP microcontrollers. These are in turn interfaced to a Sun Sparc-10 workstation through two high speed fiber optic interfaces. The system saw first-light on the Canada-France-Hawaii Telescope on Mauna Kea in March 1995. First-light on the University of Hawaii 2.2-M Telescope on Mauna Kea was in July 1995. Both runs were quite successful. A sample of some of the early science from the first light run is reported in the publication, 'Observations of Weak Lensing in Clusters with an 8192 x 8192 CCD Mosaic Camera'.

Hall, Donald N. B.↗

What happens to the large eddies when net drag reduction is achieved by outer flow manipulators?

The tandem-arranged parallel plate manipulator (TAPPM) presently used to generate a flow with net drag reduction is conditionally sampled and found to exhibit significant changes of the boundary layer's large-scale motions at 20 delta(0), where delta(0) is the boundary layer thickness at the upstream plate of the TAPPM. Flow fields in the 'valleys' are equally affected. Both turbulent and irrotational flows then reestablish themselves by 50 delta(0). Flow visualization indicates that the TAPPM wake is very coherent at 20 delta(0), and has not yet spread into the wall region, while large scale motions and the ambient response flow continue to exhibit dynamic changes. This indicates that the shielding effect of the TAPPM's wake prolongs suppression of large-scale motions, thereby reducing skin friction over a sufficiently long extent of the boundary layer to overcome device drag and yield net drag reductions.

Falco, R. E.↗

The DECLIC Research Facility - a Fertile Platform for NASA/CNES Scientific Collaboration

The DECLIC (Device for the Study of Critical Liquids and Crystalization) Facility was launched to the International Space Station (ISS) on Shuttle flight 17-A (August 2009) and has been in service for a little over three years. Activity from the three originally planned investigations, the HTI (High Temperature Insert) investigation, the ALI (Alice Like Insert) investigation and the DSI (Directional Solidication Insert) investigation has led to fruitful collaborations among a team of scientists, sponsored by NASA and CNES, to extend the utility of the inserts and the breadth of science beyond its initial scope. These follow-on investigations plan to use inserts that have been returned to earth for refurbishment, two of which (i.e., HTI-R and DSI-R) simply entail changing the test sample and the third (i.e., ALI-R) entails a slight hardware modication to allow for precise changes in sample volume. The first investigation, the Supercritical Water Mixture (SCWM) experiment, uses the refurbished HTI-R, which will accommodate a dilute aqueous mixture of Na2SO4 -0.5% w. This investigation will extend earlier observations of pure water at near-critical conditions. The second experiment uses a modified insert, the DSI-R, with a different concentration of succinonitrile-camphor than the original flight sample. This will allow, among other objectives, a detailed study of dendritic sidebranch formation in extended three-dimensional arrays, with the goal of elucidating whether noise amplication and/or a deterministic limit cycle is the main cause of sidebranch formation. The final experiment, the ALI-R, uses a sample cell with variable density to allow for additional observations of thermo-physical properties on SF6 at near critical conditions. The presentation will provide a discussion of the DECLIC facility's hardware, its modied inserts, and an overview of the extended science that will be achieved through these collaborative activities.

Hicks, Michael C.↗

Direct adaptive control of a PUMA 560 industrial robot

The implementation and experimental validation of a new direct adaptive control scheme on a PUMA 560 industrial robot is described. The testbed facility consists of a Unimation PUMA 560 six-jointed robot and controller, and a DEC MicroVAX II computer which hosts the Robot Control C Library software. The control algorithm is implemented on the MicroVAX which acts as a digital controller for the PUMA robot, and the Unimation controller is effectively bypassed and used merely as an I/O device to interface the MicroVAX to the joint motors. The control algorithm for each robot joint consists of an auxiliary signal generated by a constant-gain Proportional plus Integral plus Derivative (PID) controller, and an adaptive position-velocity (PD) feedback controller with adjustable gains. The adaptive independent joint controllers compensate for the inter-joint couplings and achieve accurate trajectory tracking without the need for the complex dynamic model and parameter values of the robot. Extensive experimental results on PUMA joint control are presented to confirm the feasibility of the proposed scheme, in spite of strong interactions between joint motions. Experimental results validate the capabilities of the proposed control scheme. The control scheme is extremely simple and computationally very fast for concurrent processing with high sampling rates.

Seraji, Homayoun↗

Fabrication and Atomic Force Microscopy Characterization of Molecular Composites of Fullerenes in Aerogel Matrix for Optical Limiting

An optical limiter is a device which exhibits a decrease in the transmittance in a material with an increase in intensity of light. Sol-gel techniques offer many advantages in the fabrication of materials. These materials possess many desirable properties for nonlinear optical (NLO) device applications which include transparency, high thermal and chemical stabilities, very low refractive index and dielectric constants. C60 shows a higher excited state absorption cross section than the ground state absorption cross section over the complete visible spectrum, and the spectrum of the excited state absorption of C60 has the same general shape as the ground state absorption. This fact suggests that fullerenes are ideal optical limiting materials. Aerogels are fabricated by sol-gel processing. One of the key issues is the dispersion of fullerenes into small and uniform pores of silica aerogel host matrices. The aerogel network was characterized by Raman spectroscopy. Atomic force microscopy is a technique with many advantages to characterize the aerogel materials. The morphology of the cleaved surface for a C60/aerogel sample shows that there are long paralleled shaped stripes with 20-30 nm in width and about 500 nm in length on the cleaved surface. The cleaved surface also was etched by 5% HF solution for one minutes, and it became smoother after HF etching. The main feature in on the surface is the spherical particles with the size of few nanometers, and no aggregated fullerenes appear. The fullerenes are well dispersed in the aerogel matrices.

Lu, W. J .↗

Comparison of Stress Relief Procedures for Cryogenic Aluminum Mirrors

The Infrared Multi-Object Spectrograph (IRMOS) is a facility instrument for the Kitt Peak National Observatory Mayall Telescope (3.8 meter) and an engineering prototype for a potential design for the Next Generation Space Telescope/Multi-Object Spectrograph. IRMOS is a low-to mid-resolution (R = lambda/delta-lambda = 300-3800), near-IR (0.8-2.5 micron) spectrograph which produces simultaneous spectra of approximately 100 objects in its 2.8 x 2.0 arcmin field of view using a commercial MEMS multimirror array device. The instrument operating temperature is 80 K and the design is athermal --- the optical bench and mirrors are machined from aluminum 6061-T651. In spite of its baseline mechanical stress relief, aluminum 6061-T651 harbors some residual stress, which, unless relieved during fabrication, may relieve and distort mirror figure to unacceptable levels at the operating temperature. Other cryogenic instruments using aluminum mirrors for both ground-based and space IR astronomy have employed a variety of heat treatment formulae, with mixed results. We present the results of a test program designed to empirically determine the best stress relief procedure for the IRMOS mirrors. Identical test mirrors with spherical and flat optical prescriptions are processed with five different heat treatment formulae from the literature and compared to samples with out any additional processing. After figuring via diamond turning, the mirrors are tested for figure error and radius of curvature at room temperature and at 80 K for several thermal cycles. The heat treatment procedure for the mirrors that yielded the least and most repeatable change in figure error and radius is applied to the IRMOS mirror blanks. We correlate the results of our optical testing with heat treatment and metallographic data.

Ohl, Raymond G.↗

A satellite anemometer

This report describes the design, development, and testing of components of a satellite anemometer, an instrument for measuring neutral winds in the upper atmosphere from a satellite platform. The device, which uses four nearly identical pressure sensors, measures the angle of arrival of the bulk neutral flow in the satellite frame of reference. It could also be used in a feedback loop to control spacecraft attitude with respect to the ram velocity direction. We have now developed miniaturized ionization pressure gauges that will work well from the slip flow region near 115 km up to the base of the exosphere, which covers the entire altitude range currently being considered for Tether. Laboratory tests have demonstrated a very linear response to changes in ram angle out to +/- 20 deg. (transverse wind component of 2.7 km s(exp -1)) from the ram, and a monotonic response to out beyond 45 deg. Pitch (vertical wind) and yaw (horizontal wind) can be sampled simultaneously and meaningfully up to 10 Hz. Angular sensitivity of 30 arc seconds (approximately 1 ms(exp -1) is readily attainable, but absolute accuracy for winds will be approximately 1 deg (130 m/s) unless independent attitude knowledge is available. The critical elements of the design have all been tested in the laboratory.

Hanson, W. B.↗

ZnO Films on {001}-Cut <110>-Propagating GaAs Substrates for Surface Acoustic Wave Device Applications

A potential application for piezoelectric films on GaAs substrates is the monolithic integration of surface acoustic wave (SAW) devices with GaAs electronics. Knowledge of the SAW properties of the layered structure is critical for the optimum and accurate design of such devices. The acoustic properties of ZnO films sputtered on {001}-cut <110> -propagating GaAs substrates are investigated in this article, including SAW Velocity effective piezoelectric coupling constant, propagation loss. diffraction, velocity surface, and reflectivity of shorted and open metallic gratings. The measurements of these essential SAW properties for the frequency range between 180 and 360 MHz have been performed using a knife-edge laser probe for film thicknesses over the range of 1.6-4 micron and with films or different grain sizes. The high quality of dc triode sputtered films was observed as evidenced by high K(exp 2) and low attenuation. The measurements of the velocity surface, which directly affects the SAW diffraction, on the bare and metalized ZnO on SiO2, or Si3N4 on {001}-cut GaAs samples are reported using two different techniques: 1) knife-edge laser probe, 2) line-focus-beam scanning acoustic microscope. It was found that near the <110> propagation direction, the focusing SAW property of the bare GaAs changes into a nonfocusing one for the layered structure, but a reversed phenomenon exists near the <100> direction. Furthermore, to some extent the diffraction of the substrate can be controlled with the film thickness. The reflectivity of shorted and open gratings are also analyzed and measured. Zero reflectivity is observed for a shorted grating. There is good agreement between the measured data and theoretical values.

Kim, Yoonkee↗

A Scintillation Counter System Design To Detect Antiproton Annihilation using the High Performance Antiproton Trap(HiPAT)

The High Performance Antiproton Trap (HiPAT), a system designed to hold up to l0(exp 12) charge particles with a storage half-life of approximately 18 days, is a tool to support basic antimatter research. NASA's interest stems from the energy density represented by the annihilation of matter with antimatter, 10(exp 2)MJ/g. The HiPAT is configured with a Penning-Malmberg style electromagnetic confinement region with field strengths up to 4 Tesla, and 20kV. To date a series of normal matter experiments, using positive and negative ions, have been performed evaluating the designs performance prior to operations with antiprotons. The primary methods of detecting and monitoring stored normal matter ions and antiprotons within the trap includes a destructive extraction technique that makes use of a micro channel plate (MCP) device and a non-destractive radio frequency scheme tuned to key particle frequencies. However, an independent means of detecting stored antiprotons is possible by making use of the actual annihilation products as a unique indicator. The immediate yield of the annihilation event includes photons and pie mesons, emanating spherically from the point of annihilation. To "count" these events, a hardware system of scintillators, discriminators, coincident meters and multi channel scalars (MCS) have been configured to surround much of the HiPAT. Signal coincidence with voting logic is an essential part of this system, necessary to weed out the single cosmic ray events from the multi-particle annihilation shower. This system can be operated in a variety of modes accommodating various conditions. The first is a low-speed sampling interval that monitors the background loss or "evaporation" rate of antiprotons held in the trap during long storage periods; provides an independent method of validating particle lifetimes. The second is a high-speed sample rate accumulating information on a microseconds time-scale; useful when trapped antiparticles are extracted against a target, providing an indication of quantity. This paper details the layout of this system, setup of the hardware components around HiPAT, and applicable checkouts using normal matter radioactive sources.

Martin, James J.↗