Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Water-based Liquid Scintillator detector as a new technology testbed for neutrino studies in Turkey

This study investigates the deployment of a medium-scale neutrino detector near Turkey's rst nuclear power plant, the Akkuyu Nuclear Power Plant. The aim of this detector is to become a modular testbed for new technologies in the elds of new detection media and innovative photosensors. Such technologies include Water-based Liquid Scintillator (WbLS), Large Area Picosecond Photo- Detectors (LAPPDs), dichroic Winston cones, and large area silicon photomul- tiplier modules. Here, the detector could be used for instantaneous monitoring of the Akkuyu Nuclear Power Plant via its antineutrino ux. In addition to its physics and technological goals, it would be an invaluable opportunity for the nuclear and particle physics community in Turkey to play a role in the development of next generation of particle detectors in the eld of neutrino physics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of the JUNO liquid scintillator composition using a Daya Bay antineutrino detector

To maximize the light yield of the liquid scintillator (LS) for the Jiangmen Underground Neutrino Observatory (JUNO), a 20 t LS sample was produced in a pilot plant at Daya Bay. The optical properties of the new LS in various compositions were studied by replacing the gadolinium-loaded LS in one antineutrino detector. The concentrations of the fluor, PPO, and the wavelength shifter, bis-MSB, were increased in 12 steps from 0.5 g/L and 0.01 mg/L to 4 g/L and 13 mg/L, respectively. The numbers of total detected photoelectrons suggest that, with the optically purified solvent, the bis-MSB concentration does not need to be more than 4 mg/L. In order to bridge the one order of magnitude in the detector size difference between Daya Bay and JUNO, the Daya Bay data were used to tune the parameters of a newly developed optical model. Then, the model and tuned parameters were used in the JUNO simulation. Overall, this enabled to determine the optimal composition for the JUNO LS: purified solvent LAB with 2.5 g/L PPO, and 1 to 4 mg/L bis-MSB.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance of neutron spectrum unfolding using deuterated liquid scintillator

The performance of the maximum likelihood expectation maximization method for unfolding neutron energy spectra using deuterated liquid scintillator is evaluated for future utilization with rare isotope beams. High-resolution neutron energy spectra as well as the detector response matrix were measured at the Edwards Accelerator Laboratory at Ohio University. Maximum-likelihood expectation maximization (MLEM) unfolded neutron spectra are compared with spectra from neutron time-of-flight. In conclusion, the effects of the MLEM stopping criteria and spectrum statistics are also investigated.

47 OTHER INSTRUMENTATION↗

Organic glass scintillator bars with dual-ended readout

Organic glass scintillator (OGS) bars (6 × 6 × 50 mm 3 ) were melt-cast and characterized with dual-ended readout by silicon photomultiplier arrays. The results were compared to trans-stilbene bars of the same size. Energy resolution was measured via a 137 Cs Compton-coincidence experiment. Time resolution was determined via a 22 Na coincidence-timing experiment. Depth-of-interaction resolution was measured by moving a gamma ray fan beam along the major axis of the bars. Pulse shape discrimination capability and neutron light output were determined via a time-of-flight measurement of a 252 Cf source. The OGS bars exhibited better energy resolution at 478 keV (10.3 ± 0.5% vs. 11.2 ± 0.5%), better time resolution from 200–341 keVee (270 ps vs. 340 ps FWHM), slightly poorer depth-of-interaction resolution, poorer PSD performance, and higher neutron light output than the stilbene bars. Here, the low cost, ease of manufacturing, brightness, and excellent time resolution make OGS a strong candidate for use in compact radiation imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic calorimeters based on scintillating lead tungstate crystals for experiments at Jefferson Lab

A new electromagnetic calorimeter consisting of 140 lead tungstate (PbWO 4 ) scintillating crystals was constructed for the PrimEx- η experiment at Jefferson lab. The calorimeter was integrated into the data acquisition and trigger systems of the GlueX detector and used in the experiment to reconstruct Compton scattering events. The experiment started collecting data in the spring of 2019 and acquired about 30% of the required statistics. The calorimeter is a prototype for two PbWO 4 -based detectors: the Neutral Particle Spectrometer (NPS) and the lead tungstate insert of the Forward CALorimeter (FCAL) of the GlueX detector. The article presents the design and performance of the Compton calorimeter and gives a brief overview of the FCAL and NPS projects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of a digitizer for the plastic scintillation detectors of time-of-flight mass measurements

A CAEN DT5742 digitizer has been investigated to process the fast signals from the photomultiplier tubes of the time-of-flight detectors for fast ion beams. A test setup consisting of two plastic scintillation detectors and a pulsed laser source provided signals which were recorded by the digitizer and systematically analyzed with different algorithms to derive the amplitude, rise time and arrival time of the detection signal. To obtain the best amplitude and time resolutions, various optimization techniques including peak fitting and signal smoothing, interpolation improvement, and time-walk correction by amplitude and rise time have been performed and compared in detail. Here we compared the time resolutions obtained by three digital algorithms of leading-edge, zero-crossing constant-fraction (ZC-CFD) and direct constant-fraction discriminations. Finally, we found that the best time-of-flight resolution between two PMTs can be achieved as 12 ps by the method using sample minimum for peak location and using the time-walk-resistant ZC-CFD with 4-point interpolation for timing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, assembly and operation of a Cosmic Ray Tagger based on scintillators and SiPMs

The Mu2e experiment at Fermilab aims to search for the SM forbidden μ – → e – conversion in Al muonic atoms. The signal signature consists of 104.96 MeV electrons, identified by a straw-tube tracker and a crystal calorimeter, made of two annular disks. Here, in order to calibrate the calorimeter disks with minimum ionizing particles (MIP) before the installation, we have realized a Cosmic Ray Tagger (CRT) at Laboratori Nazionali di Frascati (LNF) of INFN. The CRT consists of two planes of eight 2.5 x 1.5 x 160 cm 3 plastic scintillator (EJ-200) bars, coupled to SiPMs on both edges, so as to estimate longitudinal hit positions from time differences. 3D MIP tracking is achieved by reconstructing hit positions in the two planes, placed above and below the disks, and allows to calibrate the energy response, to align the time offsets, and to study the detector performances dependence along the crystals axis.

79 ASTRONOMY AND ASTROPHYSICS↗

Understanding the enhancement of scintillation light in xenon-doped liquid argon

Measuring the scintillation light in noble gases is an important detection technique in particle physics. Numerous rare event searches like neutrino beam experiments, neutrino-less double beta-decay, and dark matter searches use argon-based detectors. In liquid argon, the light yield can be enhanced by the addition of a small quantity of xenon, where ~10–1000 ppm are added. The general enhancement mechanism and its pathway via an energy transfer between argon and xenon excimers is well known, however the importance of absorption of argon excimer emission by atomic xenon has not been fully appreciated. This absorption significantly reduces the light yield in commercially available argon (extracted from air) which contains trace amounts (~0.1 ppm) of xenon. The addition of a small xenon dopant of ~10 ppm recovers this lost light resulting in an increased light yield over un-doped argon of about a factor of two. Here, in this paper, we introduce a model for the light production in xenon doped argon, including absorption and re-emission, and compare it to the measured time dependence of light emission in xenon-doped argon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method to load tellurium in liquid scintillator for the study of neutrinoless double beta decay

Herein, a method has been developed to load tellurium into liquid scintillator so as to permit searches for neutrinoless double beta decay with high sensitivity. The approach involves the synthesis of an oil-soluble tellurium compound from telluric acid and an organic diol. The process utilises distillable chemicals that can be safely handled underground and affords low radioactive backgrounds, low optical absorption and high light yields at loading levels of at least several percent Te by weight.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of charge state distributions using a scintillation screen

Absolute cross sections measured using electromagnetic devices to separate and detect heavy recoiling ions need to be corrected for charge state fractions. Accurate prediction of charge state distributions using theoretical models is not always a possibility, especially in energy and mass regions where data is sparse. As such, it is often necessary to measure charge state fractions directly. In this paper we present a novel method of using a scintillation screen along with a CMOS camera to image the charge dispersed beam after a set of magnetic dipoles. A measurement of the charge state distribution for 88 Sr passing through a natural carbon foil is performed. Using a Bayesian model to extract statistically meaningful uncertainties from these images, we find agreement between the new method and a more traditional method using Faraday cups. Additional future work is need to better understand systematic uncertainties. Our technique offers a viable method to measure charge state distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of the CAESium-iodide scintillator ARray (CAESAR) electronics and data acquisition system for optimized performance at FRIB

Here, we report on the upgrade of the electronics and data acquisition (DAQ) of the high-efficiency CAESium-iodide scintillator ARray (CAESAR) at the Facility for Rare Isotope Beams (FRIB). With the on-going capability ramp-up of FRIB, CAESAR is expected to continue to be an in-demand -ray spectrometer owing to its high detection efficiency, compactness, and modularity, enabling easy integration with additional detection and DAQ systems. Within this context, the CAESAR electronics and DAQ were upgraded to remove obsolete modules, enhance the ease of integration with external instruments, and optimize the DAQ live time. We present the comprehensive results from offline (γ-ray sources) and online (in-beam experiment) commissioning, characterizing the performance of CAESAR’s new electronics and DAQ.

CsI(Na) scintillator array↗

Experimental validation of scintillator detector response to correlated neutrons with MCNP and associated packages

Time, energy, and angle correlated neutrons are emitted in nuclear fission. New, physics-based fission event generators that capture these correlations have been incorporated into MCNP6.2 because correlations can impact nuclear non-proliferation and safeguards systems response. DRiFT is a detector response code that takes MCNP outputs and reproduces laboratory analogous detector quantities. Previous work has compared DRiFT to single detector experiment data and has discussed recent updates to DRiFT specific to correlated fission experiments. In this work, we demonstrate a validation of recent updates to DRiFT for organic scintillator response in correlated fission neutron experiments using a 252Cf source. Furthermore, outputs from MCNP with the FREYA fission event generator were post-processed with DRiFT and compared to experiment data. Simulation and experiment results are in reasonably good agreement for multiple correlated neutron quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synthesis and Screening of Thin Films in the CeCl3-CeBr3 System for Scintillator Applications

Thin film samples of CeCl3, CeBr3, and combinatorial compositions along the CeCl3-CeBr3 join were produced using thermal evaporation, which is being evaluated as a method for rapid screening of new scintillator materials. The combinatorial thin films were shown to be compositionally reproducible from run-to-run within reasonable limitations. Analytical results suggest a continuous variation in the combinatorial samples in terms of their compositions, crystal structures, and luminescence characteristics.

36 MATERIALS SCIENCE↗

Crystal structure, electronic structure, temperature-dependent optical and scintillation properties of CsCe 2 Br 7

CsCe 2 Br 7 is a self-activated inorganic scintillator that shows promising performance, but the understanding of the important structure-property relationships is lacking. In this work, we conduct a comprehensive study on CCsCe 2 Br 7 . The crystal structure of CsCe 2 Br 7 is refined using single crystal X-ray study for the first time. It crystallizes into the orthorhombic crystal system with Pmnb space group. Its electronic structure is revealed by Density Functional Theory (DFT) calculations. Two cerium emission centers are identified and the energy barriers related to the thermal quenching to 4f ground states of Ce 3+ for these two Ce centers are evaluated. CsCe 2 Br 7 single crystal has better light yield and energy resolution than CsCe 2 Cl 7 , but with an additional slow decay component of 1.7 s. The existence of a deep trap with a depth of 0.9 eV in CsCe 2 Cl 7 contributes to its higher afterglow level in comparison to that of CsCe 2 Br 7 . The most possible point defects in CsCe 2 Cl 7 and CsCe 2 Br 7 are proposed by considering the vapour pressure in the growth atmosphere upon melting point.

36 MATERIALS SCIENCE↗

A time-gating scintillation detector for the measurement of laser-induced fast neutrons

A time-gating scintillation detector, in which a fast high voltage switch is used for gating a channel photomultiplier, was developed for a measurement of laser-induced fast neutrons. The x rays generated from the intense femtosecond laser and the solid target interactions were suppressed selectively and a time-of-flight signal of a laser-generated fast neutron was measured effectively. The detector was used successfully to measure the neutron yield of a femtosecond, deuterated, polystyrene plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A time-resolved spectroscopic diagnostic based on fast scintillator and optical fiber array for z-pinch plasmas

We report a specially designed type of temporal resolved x-ray spectroscopic diagnostic using a spherically bent quartz crystal for z-pinch plasmas. Registration of time-resolved spectra was accomplished by coupling fast plastic scintillator, an optical fiber array, an optical streak camera, and a charge coupled device as the recording medium of this diagnostic. The diagnostic has been tested in imploding wire array experiments on S-300 pulsed power facility. Time-resolved K-shell lines were successfully obtained for aluminum wire array implosion plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical scattering lengths in large liquid-scintillator neutrino detectors

For liquid-scintillator neutrino detectors of kiloton scale, the transparency of the organic solvent is of central importance. The present paper reports on laboratory measurements of the optical scattering lengths of the organic solvents phenylxylylethane, linear alkylbenzene (LAB), and dodecane, which are under discussion for next-generation experiments such as SNO+ (Sudbury Neutrino Observatory), HanoHano, or LENA (Low Energy Neutrino Astronomy). Results comprise the wavelength range of 415-440 nm. The contributions from Rayleigh and Mie scattering as well as from absorption/re-emission processes are discussed. Based on the present results, LAB seems to be the preferred solvent for a large-volume detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a thermal neutron detector based on scintillating fibers and silicon photomultipliers

We propose a technique for thermal neutron detection, based on a {sup 6}Li converter placed in front of scintillating fibers readout by means of silicon photomultipliers. Such a technique allows building cheap and compact detectors and dosimeters, thus possibly opening new perspectives in terms of granular monitoring of neutron fluxes as well as space-resolved neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗