Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Detection of electric current pulses by a fibre-optic sensor using spun fibre

We have studied distinctive features of the response of a fibre-optic current sensor with a spun-fibre sensing loop to short current pulses. It has been shown theoretically that, in a reflective interferometer, the polarisation mode dispersion (PMD) in the sensing spun fibre has no effect on the pulsed output signal of the sensor, in contrast to the PMD in a connecting fibre line. The response of the current sensor to a rectangular pulse has linear edges and its duration is determined by the relationship between the current pulse duration and the light propagation time in the spun fibre. The transition from a linear edge to the maximum sensor response is not accompanied by any transient process. The maximum response amplitude corresponds to the response to an equivalent direct current at a current pulse duration exceeding the light propagation time in the spun fibre. The present calculation results and experimental data agree well for current pulses longer than 300 ns at a light propagation time in the spun fibre of ∼1 μs. (fibre-optic sensors)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Are there echoes of gravitational waves?

In several approaches to evading the information paradox, the semiclassical black hole is replaced by an Exotic Compact Object (ECO). It has been conjectured that gravitational waves emitted by the merger of ECOs can reflect off the ECOs and produce a detectable ‘echo’. We argue that while a part of the wave can indeed reflect off the surface of an ECO, this reflected wave will get trapped by a new closed trapped surface produced by its own backreaction. Thus, no detectable signal of the echo will emerge to infinity. The only assumption in this analysis is that causality is maintained to leading order in gently curved spacetime. Thus, if echoes are actually detected, then we would face a profound change in our understanding of physics.

Astronomy & Astrophysics↗

Mach-Zehnder optical configuration with Brewster window and two quarter-wave plates

Configuration is improvement because of the following: It provides higher efficiency. It reduces or eliminates feedthrough of untranslated local oscillator, which would produce a beat signal at shifted frequency of translator. When used without translator and with low-power detector, telescope secondary mirror reflects portion of output to local oscillator.

Lawrence, T. R.↗

A multidisciplinary study of earth resources imagery of Australia, Antarctica and Papua, New Guinea

The author has identified the following significant results. A thirteen category recognition map was prepared, showing forest, water, grassland, and exposed rock types. Preliminary assessment of classification accuracies showed that water, forest, meadow, and Niobrara shale were the most accurately mapped classes. Unsatisfactory results, were obtained in an attempt to discrimate sparse forest cover over different substrates. As base elevation varied from 7,000 to 13,000 ft, with an atmospheric visibility of 48 km, no changes in water and forest recognition were observed. Granodiorite recognition accuracy decreased monotonically as base elevation increased, even though the training set location was at 10,000 ft elevation. For snow varying in base elevation from 9400 to 8420 ft, recognition decreases from 99% at the 9400 ft training set elevation to 88% at 8420 ft. Calculations of expected radiance at the ERTS sensor from snow reflectance measured at the site and from Turner model calculations of irradiance, transmission and path radiance, reveal that snow signals should not be clipped, assuming that calculations and ERTS calibration constants were correct.

Fisher, N. H.↗

Received optical power calculations for optical communications link performance analysis

The factors affecting optical communication link performance differ substantially from those at microwave frequencies, due to the drastically differing technologies, modulation formats, and effects of quantum noise in optical communications. In addition detailed design control table calculations for optical systems are less well developed than corresponding microwave system techniques, reflecting the relatively less mature state of development of optical communications. Described below are detailed calculations of received optical signal and background power in optical communication systems, with emphasis on analytic models for accurately predicting transmitter and receiver system losses.

Marshall, W. K.↗

Longitudinal variation of mid-latitude hiss from six long duration balloon flights

The longitudinal variation of midlatitude hiss as measured on six balloons at latitudes of 35-55 deg S, shows a significant minimum at 70-80 deg E, about 1000 km east of the geomagnetic conjugate of the Soviet transmitter UMS (17.1 kHz). It is suggested that the well documented pitch-angle diffusion induced by the UMS signal removes the ability of the trapped electrons to maintain the amplification of the hiss to at least the reflection and reducting losses (about 20 dB) at the ends of the echoing ducted path. The eastward shift of the minimum from the conjugate of UMS is primarily caused by the time taken by the eastward-drifting electrons to recover this ability, though the effect is enhanced by the east-west asymmetry in the propagation of hiss under the ionosphere.

Dowden, R. L.↗

Unmixing AVIRIS data to provide a method for vegetation fraction subtraction

Five flight lines of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data were acquired over the Dolly Varden Mountains in northeastern Nevada on 2 June 1989. Signal-to-noise ratio values are given. The empirical line method was used to convert AVIRIS radiance values to reflectance. This method involves calculating gain and offset values for each band. These values are based upon a comparison of the imaging spectrometer data and field reflectance measurements, both taken over the same ground targets. The targets used were a dark andesite flow and a bright playa.

Zamudio, J. A.↗

Circular-Loop-Element Microwave Frequency-Selective Reflectors

Double or single planar arrays of circular loops laminated with dielectric sheets. Reflectors designed for use in multiplexing signals at several frequencies in microwave antenna system. Well suited to both circularly and linearly polarized radiation. Transmission and reflection characteristics relatively insensitive to angle of incidence. Similar device described in "Triband Circular-Loop Frequency-Selective Microwave Reflector" (NPO-18714).

Huang, John↗

The Question of Impurities in Macromolecule Crystal Quality Improvement in Microgravity

While macromolecule impurities may affect crystal size and morphology the over-riding question is how do macromolecule impurities effect crystal X-ray quality and diffraction resolution. In the case of chicken egg white lysozyme previous researchers have reported that crystals grown in the presence of ovalbumin, ovotransferrin, and turkey egg white lysozyme show no difference in diffraction resolution compared to those grown in pure solutions. One impurity however, a naturally occurring lysozyme dimer, does negatively impact the X-ray crystal properties. For this impurity it has been reported that crystal quality improvement in microgravity may be due to improved impurity partitioning during crystallization. In this study we have examined the incorporation of the dimer into lysozyme crystals, both on the ground and in microgravity experiments, and have performed detailed X-ray analysis of the crystals using a new technique for finely probing the mosaicity of the crystal at the Stanford Synchrotron Radiation Laboratory. Dimer partitioning was not significantly different in microgravity compared to the ground based experiments, although it is significantly better than that previously reported in microgravity. Mosaicity analysis of pure crystals, 1422 indexed reflections (microgravity) and 752 indexed reflections (ground), gave average results of 0.0066 and 0.0092 degrees (FWHM) respectively. The microgravity crystals also provided an increased signal to noise. Dimer incorporation increased the average mosaicity in microgravity but not on the ground. However, dimer incorporation did greatly reduce the resolution limit in both ground and microgravity grown crystals. The data is being treated anisotropically to explore these effects. These results indicate that impurity effects in microgravity are complex and that the conditions or techniques employed may greatly affect the role of impurities.

Judge, Russell A.↗

Studying Room Acoustics using a Monopole-Dipole Microphone Array

The use of a soundfield microphone for examining the directional nature of a room impulse response was reported recently. By cross-correlating monopole and co-located dipole microphone signals aligned with left-right, up-down, and front-back axes, a sense of signal direction of arrival is revealed. The current study is concerned with the array's ability to detect individual reflections and directions of arrival, as a function of the cross-correlation window duration. If is window is too long, weak reflections are overlooked; if too short, spurious detections result. Guidelines are presented for setting the window width according to perceptual criteria. Formulas are presented describing the accuracy with which direction of arrival can be estimated as a function of room specifics and measurement noise. The direction of arrival of early reflections is more accurately determined than that of later reflections which are quieter and more numerous. The transition from a fairly directional sound field at the beginning of the room impulse response to a uni-directional diffuse field is examined. Finally, it is shown that measurements from additional dipole orientations can significantly improve the ability to detect reflections and estimate their directions of arrival.

Begault, Durand R.↗

Fabry-Perot Interferometer for Column CO2: Airborne

Global atmospheric CO2 measurements are essential to resolving significant discrepancies in our understanding of the global carbon budget and, hence, humankind's role in global climate change. The science measurement requirements for CO2 are, however, extremely demanding (precision approximately 0.3%). We are developing a novel application of a Fabry-Perot interferometer to detect spectral absorption of reflected sunlight by CO2 and O2 in the atmosphere that should be able to achieve sufficient sensitivity and signal-to-noise to measure column CO2 at the target specification. We are currently constructing a prototype instrument for deployment on aircraft. The aircraft version will measure total column CO2 and CO2 below the aircraft as well as O2, which allows normalization of CO2 column amounts for varying surface height and pressure. This instrument will be a valuable asset in carbon budget field studies as well as a useful tool for evaluating existing and future space-based CO2 measurements. We will present the instrument concept, sensitivity calculations, and the results of testing a bench system in the laboratory and outdoors on the ground. We will also discuss our plan for deployment on the aircraft and potential flight applications to the CO2 budget problem.

Kawa, S. R.↗

Cationic influences upon synaptic transmission at the hair cell-afferent fiber synapse of the frog

The concentrations of inorganic cations (K+, Na+, and Ca2+) bathing the isolated frog labyrinth were varied in order to assess their role in influencing and mediating synaptic transmission at the hair cell-afferent fiber synapse. Experiments employed intracellular recordings of synaptic activity from VIIIth nerve afferents. Recordings were digitized continuously at 50 kHz, and excitatory postsynaptic potentials were detected and parameters quantified by computer algorithms. Particular attention was focused on cationic effects upon excitatory postsynaptic potential frequency of occurrence and excitatory postsynaptic potential amplitude, in order to discriminate between pre- and postsynaptic actions. Because the small size of afferents preclude long term stable recordings, alterations in cationic concentrations were applied transiently and their peak effects on synaptic activity were assessed. Increases in extracellular K+ concentration of a few millimolar produced a large increase in the frequency of occurrence of excitatory postsynaptic potentials with little change in amplitude, indicating that release of transmitter from the hair cell is tightly coupled to its membrane potential. Increasing extracellular Na+ concentration resulted in an increase in excitatory postsynaptic potential amplitude with no significant change in excitatory postsynaptic potential frequency of occurrence, suggesting that the transmitter-gated subsynaptic channel conducts Na+ ions. Decreases in extracellular Ca2+ concentration had little effect upon excitatory postsynaptic potential frequency, but increased excitatory postsynaptic potential frequency and amplitude. These findings suggest that at higher concentrations Ca2+ act presynaptically to prevent transmitter release and postsynaptically to prevent Na+ influx during the generation of the excitatory postsynaptic potential. The influences of these ions on synaptic activity at this synapse are remarkably similar to those reported at the vertebrate neuromuscular junction. The major differences between these two synapses are the neurotransmitters and the higher resting release rate and higher sensitivity of release to increased K+ concentrations of the hair cells over that of motor nerve terminals. These differences reflect the functional roles of the two synapses: the motor nerve terminal response in an all-or-nothing signal consequent from action potential invasion, while the hair cell releases transmitter in a graded fashion, proportionate to the extent of stereocilial deflection. Despite these differences between the two junctions, the similar actions of these elemental cations upon synaptic function at each implies that these ions may participate similarly in the operations of other synapses, independent of the neurotransmitter type.(ABSTRACT TRUNCATED AT 400 WORDS).

NASA Discipline Neuroscience↗

Estimates of Lightning NOx Production Based on OMI NO2 Observations Over the Gulf of Mexico

We evaluate nitrogen oxide (NO(sub x) NO + NO2) production from lightning over the Gulf of Mexico region using data from the Ozone Monitoring Instrument (OMI) aboard NASAs Aura satellite along with detection efficiency-adjusted lightning data from the World Wide Lightning Location Network (WWLLN). A special algorithm was developed to retrieve the lightning NOx [(LNO(sub x)] signal from OMI. The algorithm in its general form takes the total slant column NO2 from OMI and removes the stratospheric contribution and tropospheric background and includes an air mass factor appropriate for the profile of lightning NO(sub x) to convert the slant column LNO2 to a vertical column of LNO(sub x). WWLLN flashes are totaled over a period of 3 h prior to OMI overpass, which is the time an air parcel is expected to remain in a 1 deg. x 1 deg. grid box. The analysis is conducted for grid cells containing flash counts greater than a threshold value of 3000 flashes that yields an expected LNO(sub x) signal greater than the background. Pixels with cloud radiance fraction greater than a criterion value (0.9) indicative of highly reflective clouds are used. Results for the summer seasons during 2007-2011 yield mean LNO(sub x) production of approximately 80 +/- 45 mol per flash over the region for the two analysis methods after accounting for biases and uncertainties in the estimation method. These results are consistent with literature estimates and more robust than many prior estimates due to the large number of storms considered but are sensitive to several substantial sources of uncertainty.

Lightning↗

Remote Sensing of Solar-Induced Chlorophyll Fluorescence (SIF) in Vegetation: 50 Years of Progress

Remote sensing of solar-induced chlorophyll fluorescence (SIF) is a rapidly advancing front in terrestrial vegetation science, with emerging capability in space-based methodologies and diverse application prospects. Although remote sensing of SIF – especially from space – is seen as a contemporary new specialty for terrestrial plants, it is founded upon a multi-decadal history of research, applications, and sensor developments in active and passive sensing of chlorophyll fluorescence. Current technical capabilities allow SIF to be measured across a range of biological, spatial, and temporal scales. As an optical signal, SIF may be assessed remotely using highly-resolved spectral sensors and state-of-the-art algorithms to distinguish the emission from reflected and/or scattered ambient light. Because the red to far-red SIF emission is detectable non-invasively, it may be sampled repeatedly to acquire spatio-temporally explicit information about photosynthetic light responses and steady-state behaviour in vegetation. Progress in this field is accelerating with innovative sensor developments, retrieval methods, and modelling advances. This review distills the historical and current developments spanning the last several decades. It highlights SIF heritage and complementarity within the broader field of fluorescence science, the maturation of physiological and radiative transfer modelling, SIF signal retrieval strategies, techniques for field and airborne sensing, advances in satellite-based systems, and applications of these capabilities in evaluation of photosynthesis and stress effects. Progress, challenges, and future directions are considered for this unique avenue of remote sensing.

Review↗

Method and apparatus for instantaneous band ratioing in a reflectance radiometer

A hand-held instrument is provided to compare information from selected infrared and visible bands in the 0.4 to 2.5 micrometer range, to perform ratioing via a dividing circuit (17) and to directly read out, via a display system (18), ratio values in a continuous digital display. The dual-beam, ratioing radiometer contains two optical trains (10, 12), each having two repeater lenses (L1a, L1b and L2a, L2b) and a cooled lead sulfide detector (D1, D2). One of the trains (10) is pivotal to facilitate measurements at distances ranging from about 1 meter to infinity. The optical trains are intersected by a set of two coaxially-mounted filter wheels (F1, F2), each containing up to five interference filters and slits to pass radiation filtered by the other. Filters with band passes as narrow as 0.01 micrometer are used in the region 0.4 to 2.5 micrometers. The total time for a calibration and measurement is only a few seconds. It is known from previous field studies using prior art devices, that materials, e.g., clay minerals, and carbonate minerals such as limestone, have unique spectral properties in the 2.0 to 2.5 micrometer region. Using properly chosen spectral filters, and ratioing the signals to remove the effect of topography on the brightness measured, the instrument can be used for real-time analysis of reflecting materials in the field. Other materials in the broader range of 0.4 to 2.5 micrometers (and even beyond) could be similarly identified once the reflectance spectrum of the material is established by any means.

Goetz, Alexander F. H.↗

Monitoring changes in human activity during the COVID-19 shutdown in Las Vegas using infrasound microbarometers

While studies of urban acoustics are typically restricted to the audio range, anthropogenic activity also generates infrasound (<20 Hz, roughly at the lower end of the range of human hearing). Shutdowns related to the COVID-19 pandemic unintentionally created ideal conditions for the study of urban infrasound and low frequency audio (20–500 Hz), as closures reduced human-generated ambient noise, while natural signals remained relatively unaffected. An array of infrasound sensors deployed in Las Vegas, NV, provides data for a case study in monitoring human activity during the pandemic through urban acoustics. The array records a sharp decline in acoustic power following the temporary shutdown of businesses deemed nonessential by the state of Nevada. This decline varies spatially across the array, with stations close to McCarran International Airport generally recording the greatest declines in acoustic power. Further, declines in acoustic power fluctuate with the time of day. As only signals associated with anthropogenic activity are expected to decline, this gives a rough indication of periodicities in urban acoustics throughout Las Vegas. This study's results reflect the city's response to the pandemic and suggest spatiotemporal trends in acoustics outside of shutdowns.

58 GEOSCIENCES↗

Canopy Level Solar Induced Fluorescence for Vegetation in Controlled Experiments

Solar induced chlorophyll fluorescence (SIF) was retrieved from high resolution reflectance spectra acquired one meter above saplings of three deciduous tree species during springtime (three weeks after leaf flush) and in late summer when foliage was mature. SIF was determined by application of the Fraunhofer Line Depth (FLD) Principal to above-canopy spectra acquired with an Analytical Spectral Devices (ASD) Fieldspec spectroradiometer (3.2 nm resolution with 1.2 nm sampling interval). SIF retrievals were made at the two atmospheric oxygen (O2) absorption features that occur in the chlorophyll fluorescence (ChlF) region (660 -780 nm). These telluric features are 02V, the broader and deeper feature centered at 760 nm, but located on the shoulder of the far-red ChlF peak at 740 nm; and 023, a narrow feature centered at 688 nm that is positioned near the red ChlF peak at 685 nm. Supporting, coincident leaf level fluorescence, reflectance, photochemical and other measurements were also made. At the leaf level, these measurements included in situ photosynthetic capacity (Pmax) and light adapted total chlorophyll fluorescence (Fs') collected at steady state under high light and controlled chamber conditions (e.g., temperature, PAR, humidity, and COz); optical properties (reflectance, transmittance, absorptance); chlorophyll and carotenoid content; specific leaf mass; carbon (C) and nitrogen (N) content; fluorescence emission spectra at multiple excitation wavelengths; the ChlF contribution to red (R) and far-red (FR) reflectance; fluorescence imagery; and fluorescence excitation-emission matrices (EEMs). The tree species examined were tulip poplar (Liriodendron tulipifera L.), red maple (Acer rubrum L.), and sweetgum (Liquidambar styraczflua L.), and each had been provided four levels of N augmentation (0, 19, 37, and 75 kg Nhectare seasonally) to simulate atmospheric deposition from air pollution. Whole-plant SIF measurements of these species were compared with SIF estimates derived using FluorMOD, a radiative transfer model that includes fluorescence properties of foliage, when provided with our supporting measurements. Simulated values for SIF were also compared with similar estimates made over three years for corn (Zea mays L) crops under N treatments (20, 50,70, and 140 kg Nhectare) and with corn and pepper (Capsicum annuum L.) plants provided dimethyl urea (DCMU, 0 and 5 x 10" M) which were grown in pots and grouped in artificial canopies for spectral measurements. For near-surface measurements of healthy and stressed vegetation, red SIF retrieved at 688 nm (023) varied between 2-7 mW/m(exp 2)/nm/sr while far-red SIF retrieved at 760 nm (O2A) varied between 0.5 and 4.0 mW/m(exp 2)/nm/sr. Typical values for the SIF red/far-red ratio ranged between 1.75 and 4.0. Relationships of SIF to spectral reflectance indices and foliar photochemical indices were examined, such as photosynthetic light use efficiency. Initial investigations of the variability in these measurements at the same leaf temperature for sunlit and shaded foliage showed us that shaded foliage produced higher ChlF and light use efficiency. Other factors that affect SIF determinations are discussed. These results will assist in determine the expected intensity of the SIF signal from vegetation near the surface, as well as to identify enhancements needed for FluorMOD (or other such models), and will assist in determining relationships of SIF to reflectance indices and carbon dynamics.

Middleton, E. M.↗

Experimental determination of axion signal power of dish antennas and dielectric haloscopes using the reciprocity approach

The reciprocity approach is a powerful method to determine the expected signal power of axion haloscopes in a model-independent way. Especially for open and broadband setups like the MADMAX dielectric haloscope the sensitivity to the axion field is difficult to calibrate since they do not allow discrete eigenmode analysis and are optically too large to fully simulate. The central idea of the reciprocity approach is to measure a reflection-induced test field in the setup instead of trying to simulate the axion-induced field. In this article, the reciprocity approach is used to determine the expected signal power of a dish antenna and a minimal dielectric haloscope directly from measurements. The results match expectations from simulation but also include important systematic effects that are too difficult to simulate. In particular, the effect of antenna standing waves and higher order mode perturbations can be quantified for the first time in a dielectric haloscope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗