Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIZE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Cloud droplet size distribution broadening during diffusional growth: ripening amplified by deactivation and reactivation

Abstract. Cloud droplet size distributions (CDSDs), which are related to cloud albedo and rain formation, are usually broader in warm clouds than predicted from adiabatic parcel calculations. We investigate a mechanism for the CDSD broadening using a moving-size-grid cloud parcel model that considers the condensational growth of cloud droplets formed on polydisperse, submicrometer aerosols in an adiabatic cloud parcel that undergoes vertical oscillations, such as those due to cloud circulations or turbulence. Results show that the CDSD can be broadened during condensational growth as a result of Ostwald ripening amplified by droplet deactivation and reactivation, which is consistent with early work. The relative roles of the solute effect, curvature effect, deactivation and reactivation on CDSD broadening are investigated. Deactivation of smaller cloud droplets, which is due to the combination of curvature and solute effects in the downdraft region, enhances the growth of larger cloud droplets and thus contributes particles to the larger size end of the CDSD. Droplet reactivation, which occurs in the updraft region, contributes particles to the smaller size end of the CDSD. In addition, we find that growth of the largest cloud droplets strongly depends on the residence time of cloud droplet in the cloud rather than the magnitude of local variability in the supersaturation fluctuation. This is because the environmental saturation ratio is strongly buffered by numerous smaller cloud droplets. Two necessary conditions for this CDSD broadening, which generally occur in the atmosphere, are as follows: (1) droplets form on aerosols of different sizes, and (2) the cloud parcel experiences upwards and downwards motions. Therefore we expect that this mechanism for CDSD broadening is possible in real clouds. Our results also suggest it is important to consider both curvature and solute effects before and after cloud droplet activation in a cloud model. The importance of this mechanism compared with other mechanisms on cloud properties should be investigated through in situ measurements and 3-D dynamic models.

Yang, Fan (ORCID:0000000188666664)↗

Warm-phase microphysical evolution in large-eddy simulations of tropical cumulus congestus: evaluating drop size distribution evolution using polarimetry retrievals, in situ measurements, and a thermal-based framework

Owing to uncertainties in convective microphysics processes, improving parameterizations in Earth system models (ESMs) can benefit from observationally constrained cases suitable for scaling between cloud-resolving models and ESMs. We propose a benchmark large-eddy simulation (LES) cumulus congestus case study from the NASA Cloud, Aerosol, and Monsoon Processes Philippines Experiment (CAMP 2 Ex) for evaluating and improving ESMs in single-column model (SCM) mode. We seek observational constraints using novel polarimetric retrievals and in situ cloud microphysics measurements. Simulations using bulk and bin microphysics initialized with observed aerosol profiles are compared to cloud-top retrievals of cloud droplet effective radius (R eff ), effective variance (ν eff ), and number concentration (N d ) from the airborne Research Scanning Polarimeter (RSP). Both schemes reproduce characteristics of cloud-top N d and R eff that increase and decrease with altitude, respectively. Cloud-top N d is low-biased relative to RSP retrievals in both schemes, potentially due to limitations in both simulations and retrieval assumptions. Cloud-top R eff is low-biased in the bulk scheme but reasonably reproduced by the bin scheme. Profiles of N d and R eff are sensitive to the collision–coalescence process and the vertical variation in aerosol size distribution. Comparison of simulated and in situ droplet size distributions (DSDs) shows that, to first order, integrated moments are always sensitive to sizes < ~ 30 µm and can also be sensitive to larger sizes if the DSDs are sufficiently broad, with implications for the assumed maximum observed size retrieved by the RSP. The bin scheme captures the observed extended tail of the DSD, while the bulk scheme is unable to due to parametric constraints. Differences in expected relationships between in situ measurements of cloud cores and cloud-top retrievals by RSP demonstrate difficulty in constraining well the case presented herein. Finally, a thermal-tracking framework demonstrates that the dilution of N d throughout a thermal's lifetime is heavily determined by collision–coalescence and the height-varying aerosol distribution and that, in the absence of these, the impact of entrainment on diluting N d is largely offset by secondary activation. Implications for evaluating warm-phase convective microphysics schemes in ESMs and translating results for use on global, space-based polarimetry platforms are discussed.

Stanford, McKenna Wallace [Columbia Univ., New Yor↗

Sensitivity of aerosol optical properties to the aerosol size distribution over central Europe and the Mediterranean Basin using the WRF-Chem v.3.9.1.1 coupled model

The size distribution of atmospheric aerosols plays a key role for understanding and quantifying the uncertainties related to aerosol–radiation and aerosol–cloud interactions. These interactions ultimately depend on the size distribution through optical properties (such as aerosol optical depth, AOD) or cloud microphysical properties. Hence, the main objective of this contribution is to disentangle the impact of the representation of aerosol size distribution on aerosol optical properties over central Europe, particularly over the Mediterranean Basin, during a summertime aerosol episode. To fulfill this objective, a sensitivity test has been conducted using the coupled chemistry–meteorology model WRF-Chem (Weather Research Forecast model coupled with Chemistry). The test modified the parameters defining a lognormal size distribution (geometric diameter and standard deviation) by 10 %, 20 %, and 50 %. Results reveal that the reduction in the standard deviation of the accumulation mode leads to the largest impacts on AOD due to a transfer of particles from the accumulation mode to the coarse mode. A reduction in the geometric diameter of the accumulation mode also has an influence on AOD representation since particles in this mode are assumed to be smaller. In addition, an increase in the geometric diameter of the coarse mode produces a redistribution through the total size distribution by relocating particles from the finer modes to the coarse.

54 ENVIRONMENTAL SCIENCES↗

Size-resolved ice nucleating particle (INP) concentrations from the MOSAiC campaign

Sample collection: Ground-based immersion mode ice nucleation measurements were conducted on samples collected at the U.S. DOE ARM AMF2 onboard the R/V Polarstern P-deck during MOSAiC from 23 Oct 2019 to 01 Oct 2020. Samples were collected using a Davis Rotating-drum Unit for Monitoring (DRUM; DRUMAir, LLC) cascading impactor in 4 stages (i.e., size bins). Instrument information on the model used, the DA400, can be found at the DRUMAir website (http://www.drumair.com/). Stages A, B, C, and D had particle size cuts at 2.96, 1.21, 0.34, and 0.15 &micro;m in particle diameter, respectively. Strips of sample substrate (PFA, perfluoroalkoxy; McMaster) were adhered to each disc in each stage and coated with petrolatum to enable particles to stick on impact. The discs move slowly over time, such that aerosol loading is streaked onto the PFA. Every 24 hours, a blank is created on the PFA to separate daily samples. During MOSAiC, the pump typically pulled 20 &ndash; 35 lpm (average of 32 lpm) at the inlet with all the discs in place in each stage. Daily samples were collected for each of the four stages, equaling 28,800 &ndash; 50,400 total L of air (average of 46,080 L total L of air) per sample. Discs rotated for approximately 24 days before the sampling per strip was complete and changed to a new disc. Discs were stored frozen after collection. Sample preparation for analysis: Following collection and transport from MOSAiC to the Kreidenweis/DeMott laboratory, care of PI Creamean, in Fort Collins, CO, strips were removed from the discs and cut up to separate daily samples. Each daily portion of the strip was stored in separate sterile 15-mL centrifuge tubes and stored in a standard commercial freezer until analysis (approximately 4 &ndash; 12 months after collection). Sample analysis: Drop freezing assays (DFAs) were conducted on one daily sample set every 3 &ndash; 4 days of the study for all four stages using the Colorado State University (CSU) cold plate (CP). Sample set days were chosen to cover the entire year of MOSAiC and avoiding days where the AOS purge system was activated. Immediately after removal from the freezer, 2 mL of 0.1-&micro;m filtered deionized water was added with a single-use sterile syringe directly to the tubes, then mixed using a vortex mixer for at least 30 minutes at 500 rpm to resuspend particles from the PFA into the deionized water. Following sample preparation, another single-use syringe was used to create 100 aliquots on a 3-inch diameter copper plate, then covered with a transparent plastic dome. The drops were approximately the same volume (2.5 &micro;L each), though careful inspection. The plate was cooled at approximately 3 &ndash; 10 K min-1 from room temperature until all drops froze on the plate. Temperature was measured by an Omega thermocouple probes and meter. Drop freezing was visually detected but recorded through monitoring software to provide the time frozen, channel of the meter used, temperature, and cooling rate for each drop. Not all 100 drops were always detected; the total number of rows in each data file equals the number of drops recorded, which typically was > 80 %. Each sample was tested three times (i.e., a new set of 100 drops was created for each test). Data provided are files containing these parameters. From the freezing temperatures recorded, the fraction frozen was and INP concentrations were calculated per L of air using the equation from Vali (1971): [INPs] = &minus;(ln(f)/Valiquot)*(Vsuspension/Vair) where f is the proportion of droplets not frozen, Valiquot is the volume of each aliquot (i.e., 2.5e-6 L), Vsuspension is the volume of the suspension (i.e., 0.002 L), and Vair is the volume of air per sample (i.e., 36000 L). Data usage guidance: There are three files included with this dataset: (1) dumcp_inp_concentrations.csv which includes cumulative INP concentrations binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C for all samples and size ranges (i.e., DRUM stages) processed via DFA using the CSU CP; (2) dumcp_inp_standard_deviation.csv which includes the standard deviations for all samples and temperatures in dumcp_inp_concentrations.csv; and (3) dumcp_blank_concentrations_standard_deviation.csv which includes the INP concentrations and standard deviations for the deionized water and PFA blanks binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C. The first column in each file represents the freezing temperature in &deg;C binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C (first cell in this column = header = &ldquo;temp&rdquo;). The second column in each file represents the standard deviation of each temperature bin in &deg;C (first cell in this column = header = &ldquo;temperr&rdquo;). For file (1) dumcp_inp_concentrations.csv, the remaining columns indicate the INP concentrations per L of air for each temperature bin. For each sample column, the header in the first row indicates the stage (i.e., size bin as &ldquo;A_&rdquo;, &ldquo;B_&rdquo;, &ldquo;C_&rdquo;, or &ldquo;D_&rdquo;) and date (&ldquo;_yyyymmdd) of collection. For file (2) dumcp_inp_standard_deviation.csv, the remaining columns indicate the INP concentration standard deviation per L of air for each temperature bin. For each sample column, the header in the first row indicates the stage (i.e., size bin as &ldquo;A_&rdquo;, &ldquo;B_&rdquo;, &ldquo;C_&rdquo;, or &ldquo;D_&rdquo;) and date (&ldquo;_yyyymmdd) of collection. For file (3) dumcp_blank_concentrations_standard_deviation.csv, the remaining columns indicate the INP concentrations and standard deviations for the deionized water blank (&ldquo;di_0.1&rdquo; and &ldquo;di_0.1sd&rdquo; for the concentrations and standard deviations, respectively) and PFA blank (&ldquo;pfa&rdquo; and &ldquo;pfasd&rdquo; for the concentrations and standard deviations, respectively). Please see Creamean et al. (2019a; 2018a; 2018b; 2019b) for additional details on DRUM sample collection and offline processing. For questions or help with data interpretation, contact Dr. Jessie Creamean (jessie.creamean@colostate.edu). References: Creamean, J. M., Mignani, C., Bukowiecki, N., and Conen, F.: Using spectra characteristics to identify ice nucleating particle populations during winter storms in the Alps, Atmos. Chem. Phys., 19, 8123&ndash;8140, 2019a. Creamean, J. M., Kirpes, R. M., Pratt, K. A., Spada, N. S., Maahn, M., de Boer, G., Schnell, R. C., and China, S.: Marine and terrestrial influences on ice nucleating particles during continuous springtime measurements in an Arctic oilfield location, Atmospheric Chemistry and Physics, 18, 18023-18042, 10.5194/acp-18-18023-2018, 2018a. Creamean, J. M., Primm, K. M., Tolbert, M. A., Hall, E. G., Wendell, J., Jordan, A., Sheridan, P. J., Smith, J., and Schnell, R. C.: HOVERCAT: A novel aerial system for evaluation of aerosol-cloud interactions, Atmospheric Measurement Techniques, 11, 3969-3985, 10.5194/amt-11-3969-2018, 2018b. Creamean, J. M., Cross, J. N., Pickart, R., McRaven, L., Lin, P., Pacini, A., Hanlon, R., Schmale, D. G., Ceniceros, J., Aydell, T., Colombi, N., Bolger, E., and DeMott, P. J.: Ice nucleating particles carried from below a phytoplankton bloom to the Arctic atmosphere, Geophys. Res. Lett., 46, 8572-8581, https://doi.org/10.1029/2019GL083039, 2019b. Vali, G.: Quantitative Evaluation of Experimental Results an the Heterogeneous Freezing Nucleation of Supercooled Liquids, Journal of the Atmospheric Sciences, 28, 402-409, 10.1175/1520-0469(1971)028<0402:qeoera>2.0.co;2, 1971.

4-stage DRUM aerosol collector (DA400),Ice nuclei,↗

NPFTURBULENCE: Best Estimate Aerosol Size Distribution by airborne measurements

The original data were collected during the field campaign of “Turbulent layers promoting New Particle Formation” experiment (NPFTURBULENCE; https://www.arm.gov/research/campaigns/aaf2024npfturbulence) over the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/sgp ) in north-central Oklahoma. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS) was based at Blackwell–Tonkawa Municipal Airport (IATA: BWL, ICAO: KBKN, FAA LID: BKN, 36.74475° N, 97.34918° W, 313.9 m MSL), for the field campaign from May 5 through May 29, 2024. The ArcticShark UAS performed 11 flights, including 10 research flights over the Central Facility of the ARM SGP to measure atmospheric state, turbulence, surface IT temperature and imagery, aerosol number concentration and size distribution. The current data set presents Best Estimate Aerosol Size Distribution: a merged aerosol size distribution composed of the data from 2 sensors: miniaturized Scanning Electrical Mobility Sizer (mSEMS) and Portable Optical Particle Spectrometer (POPS). The mSEMS data were interpolated to 1 second from “native” time resolution of about 15 second to match the other probe. The POPS data were converted from equivalent optical size into geometric size using value of aerosol refractive index of 1.477 from the HISCALE field campaign (same geographical area, altitudes, and time of year; http://www.arm.gov/campaigns/aaf2016hiscale ).

54 ENVIRONMENTAL SCIENCES↗

Enhancing Building Energy Efficiency through Advanced Sizing and Dispatch Methods for Energy Storage

Energy storage and electrification of buildings hold great potential for future decarbonization. However, there are several technical and economic barriers that prevent large-scale adoption and integration of energy storage in buildings. These barriers include integration with building control systems, high capital costs, and the necessity to identify and quantify value streams for different stakeholders. To overcome these obstacles, it is crucial to develop advanced sizing and dispatch methods to assist planning and operational decision-making for integrating energy storage in buildings. This work develops simple and flexible optimal sizing and dispatch framework for thermal energy storage (TES) and battery energy storage (BES) systems in large-scale office building. The optimal sizes of TES, BES, as well as other building assets are determined in a joint manner instead of sequentially to avoid sub-optimal solutions. The interaction between the sizing at the planning stage and hourly or sub-hourly dispatch at the operating stage is explicitly modeled. The solution is determined considering both capital costs in optimal sizing and operational benefits in optimal dispatch. Comprehensive assessments are performed using simulation studies to quantify potential energy, economic, and emission benefits by different utility tariffs and climate locations, to improve our understanding of the techno-economic performance of different TES and BES systems, and to identify barriers for adopting energy storage for buildings. Finally, the proposed framework will provide guidance to a broad range of stakeholders to properly design energy storage in buildings and maximizes potential benefits, thereby advancing affordable building energy storage deployment and helping us accelerating the transition towards a cleaner and more equitable energy economy.

Yu, Mingyung↗

Heliostat Sizing Methodology for Solar Heat for Industrial Processes

This study presents a method to obtain a heliostat size that minimizes the levelized cost of a heliostat-based concentrating solar thermal system for industrial process heat (IPH) applications at operating temperatures from 565 to 1550 degrees Celsius. The method extends prior work by embedding a routine for system design that obtains near-optimal subsystem sizes, increasing the fidelity of drive cost functions, and adding an optical performance model. An illustrative business case is developed for Daggett, California, targeting specified annual thermal energy outputs of 50 to 400 GWhth. Optical performance is modeled using verified estimates from the literature. A surrogate heliostat cost model, derived from commercial heliostat designs and scaled for production volume, installation, and operations and maintenance costs, is used to develop cost functions. Results show that heliostat size strongly affects the levelized cost of heat (LCOH), producing a characteristic U-shaped trend with a robust near-optimal window of 8 - 12 m2; the heliostat size producing the lowest project cost in our study grows slightly as the project size increases, and is reduced as the operating temperature increases. The findings in this study are consistent with the general trend of smaller heliostats under deployment at existing projects for high-temperature industrial process heat and reflect the significant reduction in power electronics and other per-heliostat costs. The methodology we propose is general and can be tailored to revised cost curves as the technology continues to evolve.

14 SOLAR ENERGY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

The effects of particle size on the optical properties and surface roughness of a glass-balloon-filled black paint

The effects of particle size on the optical properties and surface roughness of a glass-balloon-filled, carbon-pigmented paint were studied in order to develop a diffuse-reflecting, low-total-reflectance, low-outgassing black paint. Particle sizes ranged between 20 microns and 74 microns. Surface roughness was found to increase with increasing particle size. Relative total reflectance at near-normal incidence (MgO standard) of the filled paints was less than for the unfilled paint between 230 nm and 1800 nm. Total absolute reflectance at 546 nm decreased with increasing particle size at grazing angles of incidence. Near-normal, total emittance was greater for the filled paints than for the unfilled paint. Specularity decreased with increasing particle size over the range studied.

Heslin, T.↗

Simultaneous calculation of aircraft design loads and structural member sizes

A design process which accounts for the interaction between aerodynamic loads and changes in member sizes during sizing of aircraft structures is described. A simultaneous iteration procedure is used wherein both design loads and member sizes are updated during each cycle yielding converged, compatible loads and member sizes. A description is also given of a system of programs which incorporates this process using lifting surface theory to calculate aerodynamic pressure distributions, using a finite-element method for structural analysis, and using a fully stressed design technique to size structural members. This system is tailored to perform the entire process with computational efficiency in a single computer run so that it can be used effectively during preliminary design. Selected results, considering maneuver, taxi, and fatigue design conditions, are presented to illustrate convergence characteristics of this iterative procedure.

Giles, G. L.↗

Grain size and the evolution of lunar soils

Grain-size data are presented for Apollo-17 soils, and the relationship is considered between grain-size distribution and the processes which pulverize the soil, reconstitute it as agglutinates, and replenish it with fresh material. It is shown that a strong inverse correlation exists between mean grain size and standard deviation and that there is a correlation between grain size and agglutinate content whereby the finest samples have the highest agglutinate content. Two evolutionary sequences are described for the soils in which (1) reworking by micrometeorites predominates over mixing with other soils and (2) mixing predominates over reworking. It is shown that the final result of soil evolution may be a steady-state soil where pulverization by micrometeorites is balanced by agglutination and replenishment of coarser grains. A model is presented for such a soil, and it is argued that its grain-size distribution may depend on regolith thickness.-

Mckay, D. S.↗

Computerized structural sizing at NASA Langley Research Center

Programs at the NASA Langley Research Center associated with the development of computerized structural sizing technology are reviewed. Particular attention is given to (1) lightweight columns for space structure applications, (2) stiffened composite panels for aerospace structures, (3) thermal structures for high-speed aircraft and space vehicles, (4) structural sizing methodology for finite-element structural models, (5) the sizing of large complex structural systems in multidisciplinary environments. Improvements to computational efficiency are noted with reference to a reduced number of sizing variables, a reduced number of constraints, and improved sizing algorithms.

Stroud, W. J.↗

Grain size and the evolution of Luna 24 soils

The grain size distribution of six Luna 24 samples has been determined. These samples are characterized by a bimodal distribution which is indicative of soils formed primarily by mixing rather than by reworking. Although agglutinate content decreases with depth, it is not likely that the Luna 24 soils have undergone appreciable in situ reworking. Particle types and abundances in each of four size fractions have been determined petrographically. Mineral fragments are very abundant in all analyzed size fractions. Pyroxene and plagioclase increase slightly in abundance at finer grain sizes, but olivine decreases significantly. Compared with typical mare soils, the Luna 24 trends are anomalous. They are compatible with the hypothesis than many, if not most, of the mineral grains in the 20-250-micron fractions come from coarse-grain rocks having average mineral grain sizes greater than 250 microns. The mineralogy and chemistry of the coarse-grained rocks has not been well characterized, but there is evidence that at least some of them are higher in MgO than the analyzed finer-grained basalts.

Mckay, D. S.↗

Field size, length, and width distributions based on LACIE ground truth data

The development of agricultural remote sensing systems requires knowledge of agricultural field size distributions so that the sensors, sampling frames, image interpretation schemes, registration systems, and classification systems can be properly designed. Malila et al. (1976) studied the field size distribution for wheat and all other crops in two Kansas LACIE (Large Area Crop Inventory Experiment) intensive test sites using ground observations of the crops and measurements of their field areas based on current year rectified aerial photomaps. The field area and size distributions reported in the present investigation are derived from a representative subset of a stratified random sample of LACIE sample segments. In contrast to previous work, the obtained results indicate that most field-size distributions are not log-normally distributed. The most common field size observed in this study was 10 acres for most crops studied.

Pitts, D. E.↗

A brittle to ductile transition in NiAl of a critical grain size

Tensile tests have been carried out on the strongly ordered B2 aluminide NiAl at 400 C to investigate the effect of the grain size on the ductility of the material. It is found that the ductility is very low and essentially independent of the grain size for aggregates of grains larger than about 20 microns; for finer-grained aggregates, the ductility increases sharply with decreasing grain size. Thus, NiAl exhibits a critical grain size below which polycrystalline aggregates are ductile in tension. For all grain sizes, fracture occurs in a brittle manner through a combination of intergranular decohesion and transgranular cleavage.

Schulson, E. M.↗

Estimating optimal sampling unit sizes for satellite surveys

This paper reports on an approach for minimizing data loads associated with satellite-acquired data, while improving the efficiency of global crop area estimates using remotely sensed, satellite-based data. Results of a sampling unit size investigation are given that include closed-form models for both nonsampling and sampling error variances. These models provide estimates of the sampling unit sizes that effect minimal costs. Earlier findings from foundational sampling unit size studies conducted by Mahalanobis, Jessen, Cochran, and others are utilized in modeling the sampling error variance as a function of sampling unit size. A conservative nonsampling error variance model is proposed that is realistic in the remote sensing environment where one is faced with numerous unknown nonsampling errors. This approach permits the sampling unit size selection in the global crop inventorying environment to be put on a more quantitative basis while conservatively guarding against expected component error variances.

Hallum, C. R.↗

Size distributions of air showers accompanied with high energy gamma ray bundles observed at Mt. Chacaltaya

Size distributions of air showers accompanied with bundle of high energy gamma rays and/or large size bursts under emulsion chambers, to study the composition of primary cosmic rays and also characteristics of high energy nuclear interaction. Air showers initiated by particles with a large cross section of interaction may develop from narrow region of the atmosphere near the top. Starting levels of air showers by particles with smaller cross section fluctuate in wider region of the atmosphere. Air showers of extremely small size accompanied with bundle of gamma rays may be ones initiated by protons at lower level after penetrating deep atmosphere without interaction. It is determined that the relative size distribution according to the total energy of bundle of gamma rays and the total burst size observed under 15 cm lead absorber.

Matano, T.↗

Production of Large-Particle-Size Monodisperse Latexes in Microgravity

A latex is a suspension of very tiny (micrometer-size) plastic spheres in water, stabilized by emulsifiers. The growth of billions of these tiny plastic spheres to sizes larger than can be grown on Earth is attempted while keeping all of them exactly the same size and perfectly spherical. Thus far on several of the Monodisperse Latex Reactor (MLR) flights, the latex spheres have been returned to Earth with standard deviations of better than 1.4%. In microgravity the absence of buoyancy effects has allowed growth of the balls up to 30 micrometers in diameter thus far. The MLR has now flown 5 times on the Shuttle. The MLR has now produced the first commercial space product; that is the first commercial material ever manufactured in space and marketed on Earth. Once it is demonstrated that these large-size-monodisperse latexes can be routinely produced in quantity and quality, they can be marketed for many types of scientific applications. They can be used in biomedical research for such things as drug carriers and tracers in the body, human and animal blood flow studies, membrane and pore-sizing in the body, and medical diagnostic tests.

Vanderhoff, J. W.↗