Search NASA⌕ Search

SEARCH · Search NASA

Results for “STANDARDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Studying Type II supernovae as cosmological standard candles using the Dark Energy Survey

ABSTRACT Despite vast improvements in the measurement of the cosmological parameters, the nature of dark energy and an accurate value of the Hubble constant (H0) in the Hubble–Lemaître law remain unknown. To break the current impasse, it is necessary to develop as many independent techniques as possible, such as the use of Type II supernovae (SNe II). The goal of this paper is to demonstrate the utility of SNe II for deriving accurate extragalactic distances, which will be an asset for the next generation of telescopes where more-distant SNe II will be discovered. More specifically, we present a sample from the Dark Energy Survey Supernova Program (DES-SN) consisting of 15 SNe II with photometric and spectroscopic information spanning a redshift range up to 0.35. Combining our DES SNe with publicly available samples, and using the standard candle method (SCM), we construct the largest available Hubble diagram with SNe II in the Hubble flow (70 SNe II) and find an observed dispersion of 0.27 mag. We demonstrate that adding a colour term to the SN II standardization does not reduce the scatter in the Hubble diagram. Although SNe II are viable as distance indicators, this work points out important issues for improving their utility as independent extragalactic beacons: find new correlations, define a more standard subclass of SNe II, construct new SN II templates, and dedicate more observing time to high-redshift SNe II. Finally, for the first time, we perform simulations to estimate the redshift-dependent distance-modulus bias due to selection effects.

79 ASTRONOMY AND ASTROPHYSICS↗

IEC STANDARDS FOR INDIVIDUAL MONITORING OF IONISING RADIATION

This paper presents IEC/SC 45B Radiation protection instrumentation and its standards for individual monitoring of ionising radiation: IEC 61526 Ed. 3 for active personal dosemeters and IEC 62387-1 for passive integrating dosimetry systems. The transposition of these standards as CENELEC (European) standards is also discussed together with the collaboration between IEC/SC 45B and ISO/TC 85/SC 2.

61 RADIATION PROTECTION AND DOSIMETRY↗

BRAINformat: A Data Standardization Framework for Neuroscience Data

Neuroscience is entering the era of `extreme data` with little experience and few plans for the associated volume, velocity, variety, and veracity challenges. This is a serious impediment for both the sharing of data across labs, as well as the utilization of modern and high-performance computing capabilities to enable data driven discovery. Here, we introduce BRAINformat, a novel file format and model for management and storage of neuroscience data. The BRAINformat library defines application-independent design concepts and modules that together create a general framework for standardization of scientific data. We describe the formal specification of scientific data standards, which facilitates sharing and verification of data and formats. We introduce the concept of Managed Objects, enabling semantic components of data formats to be specified as self-contained units, supporting modular and reusable design of data format components and file storage. The BRAINformat is built off of HDF5, enabling portable, scalable, and self-describing data storage. We introduce the novel concept of Relationship Attributes for modeling and use of semantic relationships between data objects, and discuss the annotation of data using dedicated data annotation modules provided by the BRAINformat library. Based on these concepts we implement dedicated, application-oriented modules and design a data standard for neuroscience data.The BRAINformat software library is open source, easy-to-use, and provides detailed user and developer documentation and is freely available at: https://bitbucket.org/oruebel/brainformat.

59 BASIC BIOLOGICAL SCIENCES↗

Magnetic field sensing beyond the standard quantum limit under the effect of decoherence

Entangled states can potentially be used to outperform the standard quantum limit by which every classical sensor is bounded. However, entangled states are very susceptible to decoherence, and so it is not clear whether one can really create a superior sensor to classical technology via a quantum strategy which is subject to the effect of realistic noise. This paper presents an investigation of how a quantum sensor composed of many spins is affected by independent dephasing. We adopt general noise models including non-Markovian effects, and in these noise models the performance of the sensor depends crucially on the exposure time of the sensor to the field. We have found that, by choosing an appropriate exposure time within the non-Markovian time region, an entangled sensor does actually beat the standard quantum limit. Since independent dephasing is one of the most typical sources of noise in many systems, our results suggest a practical and scalable approach to beating the standard quantum limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Surpassing the standard quantum limit in an atom interferometer with four-mode entanglement produced from four-wave mixing

We theoretically investigate a scheme for atom interferometry that surpasses the standard quantum limit. A four-wave mixing scheme similar to the recent experiment performed by Pertot et al.[Phys. Rev. Lett. 104, 200402 (2010)] is used to generate subshotnoise correlations between two modes. These two modes are then interfered with the remaining two modes in such a way as to surpass the standard quantum limit, whilst utilizing all of the available atoms. Our scheme can be viewed as using two correlated interferometers. That is, the signal from each interferometer when looked at individually is classical, but there are correlations between the two interferometers that allow for the standard quantum limit to be surpassed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adiabatic release measurements in aluminum between 400 and 1200 GPa: Characterization of aluminum as a shock standard in the multimegabar regime

Aluminum has been used prolifically as an impedance matching standard in the multimegabar regime (1 Mbar = 100 GPa), particularly in nuclear driven, early laser driven, and early magnetically driven flyer plate experiments. The accuracy of these impedance matching measurements depends upon the knowledge of both the Hugoniot and release or reshock response of aluminum. Here, we present the results of several adiabatic release measurements of aluminum from ~400–1200 GPa states along the principal Hugoniot using full density polymethylpentene (commonly known as TPX), and both ~190 and ~110 mg/cc silica aerogel standards. Additionally, these data were analyzed within the framework of a simple, analytical model that was motivated by a first-principles molecular dynamics investigation into the release response of aluminum, as well as by a survey of the release response determined from several tabular equations of state for aluminum. Combined, this theoretical and experimental study provides a method to perform impedance matching calculations without the need to appeal to any tabular equation of state for aluminum. Furthermore, as an analytical model, this method allows for propagation of all uncertainty, including the random measurement uncertainties and the systematic uncertainties of the Hugoniot and release response of aluminum. This work establishes aluminum for use as a high-precision standard for impedance matching in the multimegabar regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Developing quartz and molybdenum as impedance-matching standards in the 100-Mbar regime

We present quartz and molybdenum single-shock Hugoniot data to 62 Mbar and 120 Mbar, respectively. Quartz and molybdenum are attractive standard materials for Hugoniot equation-of-state impedance-matching studies. Quartz is advantageous because a reflecting shock front is supported above ~1 Mbar whose velocity can be tracked in situ to very high accuracy. Molybdenum's relatively high impedance makes it a more appropriate standard for other high-impedance material studies to avoid large departures from the standard principal Hugoniot upon release or reshock into the sample. Extensive measurements already exist for both materials up to about 10 Mbar and 10 eV, but new high-energy-density facilities and techniques have extended the experimentally accessible pressure range to >100 Mbar. The data presented here indicate which modern equation-of-state models can be reliably extended into newly-accessible experimental regimes.

36 MATERIALS SCIENCE↗

Photonuclear cross sections for 197 Au: An update on the gold standard

Cross sections for the 197 Au(γ, n) reaction are broadly used in nuclear physics as a standard for normalizing photonuclear reaction cross-section data at photon beam energies above approximately 8 MeV. In this paper, we report cross-section measurements for the 197 Au(γ, n) 196 Au g+m1 reaction at beam energies from 13 to 31 MeV. Our measurements provide the first cross-section data for this reaction at beam energies above 20 MeV, enabling the use of this reaction as a cross-section standard up to 30 MeV. Also, this work provides first cross-section measurements for the 197 Au(γ, n) 196 Au m2 reaction. In addition, we measured cross-section data for the 197 Au(γ, 3n) 194 Au reaction, which can be used as a cross-section standard above about 25 MeV. These measurements were performed using a new target activation method that is based on the angle-energy correlation of the laser Compton- scattered photon beams at the High Intensity Gamma-ray Source (HIγS). The technique enables measuring photonuclear reaction cross-sections at several discrete beam energies concurrently via a single irradiation on a stack of different targets. Measurements were carried out by irradiating a stack of concentric-ring targets consisting of Au, TiO 2 , Zn, Os, and Au (in order of the γ-ray beam direction). Our data for the 197 Au(γ,n) 196 Au g+m1 reaction in the energy range of 13 to 20 MeV are in good agreement with existing ones measured using monoenergetic γ-ray beams, but differ from data acquired using a bremsstrahlung γ-ray beam. Also, above 18 MeV, our data for the 197 Au(γ,n) 196 Au g+m1 and 197 Au(γ,n) 196 Au m2 reactions differ significantly from the most recent TENDL and JENDL evaluations, suggesting a need to update these data libraries. Furthermore, the TENDL evaluation and existing data are consistent with our data for the 197 Au(γ,3n) reaction, but differ significantly from the JENDL evaluation above 26 MeV.

190 ≤ A ≤ 219↗

New exact solutions of the standard pairing model for well-deformed nuclei

A new step-by-step diagonalization procedure for evaluating exact solutions of the nuclear deformed mean-field plus pairing interaction model is proposed via a simple Bethe ansatz in each step from which the eigenvalues and corresponding eigenstates can be obtained progressively. This new approach draws upon an observation that the original one- plus two-body problem in a k-particle Hilbert subspace can be mapped onto a one-body grand hard-core boson picture that can be solved step by step with a simple Bethe ansatz known from earlier work. Based on this new procedure, it is further shown that the extended pairing model for deformed nuclei [Feng Pan, V. G. Gueorguiev, and J. P. Draayer, Phys. Rev. Lett. 92, 112503 (2004)] is similar to the standard pairing model with the first step approximation, in which only the lowest energy eigenstate of the standard pure pairing interaction part is taken into consideration. Our analysis shows that the standard pairing model with the first step approximation displays similar pair structures of the first few exact low-lying states of the model, which, therefore, provides a link between the two models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use and abuse of the model waveform accuracy standards

Accuracy standards have been developed to ensure that the waveforms used for gravitational-wave data analysis are good enough to serve their intended purposes. These standards place constraints on certain norms of the frequency-domain representations of the waveform errors. Examples are given here of possible misinterpretations and misapplications of these standards, whose effect could be to vitiate the quality control they were intended to enforce. Suggestions are given for ways to avoid these problems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Search for standard model Higgs boson production in association with a W boson using a matrix element technique at CDF in pp̄ collisions at √s=1.96 TeV

This paper presents a search for standard model Higgs boson production in association with a W boson using events recorded by the CDF experiment in a data set corresponding to an integrated luminosity of 5.6 fb⁻¹. The search is performed using a matrix element technique in which the signal and background hypotheses are used to create a powerful discriminator. The discriminant output distributions for signal and background are fit to the observed events using a binned likelihood approach to search for the Higgs boson signal. We find no evidence for a Higgs boson, and 95% confidence level (C.L.) upper limits are set on σ(pp̄→WH)×B(H→bb¯). The observed limits range from 3.5 to 37.6 relative to the standard model expectation for Higgs boson masses between mH=100 GeV/c² and mH=150 GeV/c². The 95% C.L. expected limit is estimated from the median of an ensemble of simulated experiments and varies between 2.9 and 32.7 relative to the production rate predicted by the standard model over the Higgs boson mass range studied.

Aaltonen, T.↗

IEC 61850: Technology Standards and Cyber-Security Threats

Substations constitute a fundamental part in providing reliable electricity to consumers. For a substation to maintain electricity reliability and its own real-time operability, communication between its components is inevitable. Before the emergence of IEC 61850, inter-substation communication was established via expensive copper wires with limited capabilities. IEC 61850 is the standard set by the International Electrotechnical Commission (IEC) Technical Committee Number 57 Working Group 10 and IEEE for Ethernet (IEEE 802.3)-based communication in electrical substations. Like many power grid systems standards, IEC 61850 was set without extensive consideration for critical security measures. This paper discusses IEC 61850 technology standards and applications thoroughly and points out major security vulnerabilities it introduces in the context of current cyber-physical smart grid systems.

97 MATHEMATICS AND COMPUTING↗

The Vertebrate Breed Ontology: Toward Effective Breed Data Standardization

Abstract Background Limited universally-adopted data standards in veterinary medicine hinder data interoperability and therefore integration and comparison; this ultimately impedes the application of existing information-based tools to support advancement in diagnostics, treatments, and precision medicine. Hypothesis/Objectives A single, coherent, logic-based standard for documenting breed names in health, production, and research-related records will improve data use capabilities in veterinary and comparative medicine. Animals No live animals were used. Methods The Vertebrate Breed Ontology (VBO) was created from breed names and related information compiled from the Food and Agriculture Organization of the United Nations, breed registries, communities, and experts, using manual and computational approaches. Each breed is represented by a VBO term that includes breed information and provenance as metadata. VBO terms are classified using description logic to allow computational applications and Artificial Intelligence–readiness. Results VBO is an open, community-driven ontology representing over 19 500 livestock and companion animal breed concepts covering 49 species. Breeds are classified based on community and expert conventions (e.g., cattle breed) and supported by relations to the breed's genus and species indicated by National Center for Biotechnology Information (NCBI) Taxonomy terms. Relationships between VBO terms (e.g., relating breeds to their foundation stock) provide additional context to support advanced data analytics. VBO term metadata includes synonyms, breed identifiers/codes, and attributed cross-references to other databases. Conclusion and Clinical Importance The adoption of VBO as a standard for breed names in databases and veterinary electronic health records enhances veterinary data interoperability and computability, supporting precision medicine.

Veterinary Sciences↗

Need for LWR metrology standardization: the imec roughness protocol

© 2018 Society of Photo-Optical Instrumentation Engineers (SPIE). As semiconductor technology keeps moving forward, undeterred by the many challenges ahead, one specific deliverable is capturing the attention of many experts in the field: line width roughness (LWR) specifications are expected to be <2 nm in the near term, and to drop below 1 nm in just a few years. This is a daunting challenge and engineers throughout the industry are trying to meet these targets using every means at their disposal. However, although current efforts are surely admirable, we believe they are not enough. The fact is that a specification has a meaning only if there is an agreed methodology to verify if the criterion is met or not. Such standardization is critical in any field of science and technology and the question that we need to ask ourselves today is whether we have a standardized LWR metrology or not. In other words, if a single reference sample were provided, would everyone measuring it get reasonably comparable results? We came to realize that this is not the case and that the observed spread in the results throughout the industry is quite large. In our opinion, this makes the comparison of LWR data among institutions, or to a specification, very difficult. We report the spread of measured LWR data across the semiconductor industry. We investigate the impact of image acquisition, measurement algorithm, and frequency analysis parameters on LWR metrology. We review critically some of the International Technology Roadmap for Semiconductors (ITRS) metrology guidelines [such as measurement box length >2 μm and the need to correct for scanning electron microscope (SEM) noise]. We compare the SEM roughness results to AFM measurements. Finally, we propose a standardized LWR measurement protocol - the imec roughness protocol - intended to ensure that every time LWR measurements are compared (from various sources or to specifications), the comparison is sensible and sound. We deeply believe that the industry is at a point where it is imperative to guarantee that when talking about a critical parameter such as LWR, everyone speaks the same language, which is not currently the case.

Lorusso, Gian Francesco↗

Binary pseudo-random array standard for extreme ultraviolet lithography tool characterization

Extreme ultraviolet (EUV) imaging tools play a crucial role in EUV lithography. Achieving high accuracy in EUV metrology is essential for advanced semiconductor manufacturing. A thorough characterization of the instrumentation in use is required. Binary pseudo-random arrays (BPRAs) are an established standard for calibrating and characterizing optical instruments in the frequency domain. Here, we expand the BPRA standard to applications in EUV imaging. To extend the technology to the EUV spectral range, a high-resolution BPRA target with the smallest feature size of 40 nm is developed. The EUV BPRA target establishes an in situ and portable calibration and alignment standard for EUV imaging. The target is patterned by means of electron-beam lithography, using a nickel absorber with a thickness of 39 nm. The substrate is a 4″ silicon wafer with a molybdenum/silicon multilayer coating. To demonstrate the efficacy of the target and develop the instrument calibration protocol, the target is imaged on the Sharp Hyper-NA Actinic Reticle Review Project EUV mask microscope. Power spectral density (PSD) data are presented. The characteristics of the imaging system are imprinted on the PSD. The modulation transfer function is extracted from the PSD data. A partially coherent imaging model is used as a reference to the experimental results.

BPRA↗

WE-D-9A-03: CSDF: A Color Extension of the Grayscale Standard Display Function

Purpose: Use of color images in medical imaging has increased significantly the last few years. As of today there is no agreed standard on how color information needs to be visualized on medical color displays, resulting into large variability of color appearance and it making consistency and quality assurance a challenge. This paper presents a proposal for an extension of DICOM GSDF towards color. Methods: Visualization needs for several color modalities (multimodality imaging, nuclear medicine, digital pathology, quantitative imaging applications…) have been studied. On this basis a proposal was made for desired color behavior of color medical display systems and its behavior and effect on color medical images was analyzed. Results: Several medical color modalities could benefit from perceptually linear color visualization for similar reasons as why GSDF was put in place for greyscale medical images. An extension of the GSDF (Greyscale Standard Display Function) to color is proposed: CSDF (color standard display function). CSDF is based on deltaE2000 and offers a perceptually linear color behavior. CSDF uses GSDF as its neutral grey behavior. A comparison between sRGB/GSDF and CSDF confirms that CSDF significantly improves perceptual color linearity. Furthermore, results also indicate that because of the improved perceptual linearity, CSDF has the potential to increase perceived contrast of clinically relevant color features. Conclusion: There is a need for an extension of GSDF towards color visualization in order to guarantee consistency and quality. A first proposal (CSDF) for such extension has been made. Behavior of a CSDF calibrated display has been characterized and compared with sRGB/GSDF behavior. First results indicate that CSDF could have a positive influence on perceived contrast of clinically relevant color features and could offer benefits for quantitative imaging applications. Authors are employees of Barco Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-E-T-552: Monte Carlo Calculation of Correction Factors for a Free-Air Ionization Chamber in Support of a National Air-Kerma Standard for Electronic Brachytherapy

Purpose: To use Monte Carlo radiation transport methods to calculate correction factors for a free-air ionization chamber in support of a national air-kerma standard for low-energy, miniature x-ray sources used for electronic brachytherapy (eBx). Methods: The NIST is establishing a calibration service for well-type ionization chambers used to characterize the strength of eBx sources prior to clinical use. The calibration approach involves establishing the well-chamber’s response to an eBx source whose air-kerma rate at a 50 cm distance is determined through a primary measurement performed using the Lamperti free-air ionization chamber. However, the free-air chamber measurements of charge or current can only be related to the reference air-kerma standard after applying several corrections, some of which are best determined via Monte Carlo simulation. To this end, a detailed geometric model of the Lamperti chamber was developed in the EGSnrc code based on the engineering drawings of the instrument. The egs-fac user code in EGSnrc was then used to calculate energy-dependent correction factors which account for missing or undesired ionization arising from effects such as: (1) attenuation and scatter of the x-rays in air; (2) primary electrons escaping the charge collection region; (3) lack of charged particle equilibrium; (4) atomic fluorescence and bremsstrahlung radiation. Results: Energy-dependent correction factors were calculated assuming a monoenergetic point source with the photon energy ranging from 2 keV to 60 keV in 2 keV increments. Sufficient photon histories were simulated so that the Monte Carlo statistical uncertainty of the correction factors was less than 0.01%. The correction factors for a specific eBx source will be determined by integrating these tabulated results over its measured x-ray spectrum. Conclusion: The correction factors calculated in this work are important for establishing a national standard for eBx which will help ensure that dose is accurately and consistently delivered to patients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-AB-BRA-04: Quantitative Radiomics: Sensitivity of PET Textural Features to Image Acquisition and Reconstruction Parameters Implies the Need for Standards

Purpose: Despite increased use of heterogeneity metrics for PET imaging, standards for metrics such as textural features have yet to be developed. We evaluated the quantitative variability caused by image acquisition and reconstruction parameters on PET textural features. Methods: PET images of the NEMA IQ phantom were simulated with realistic image acquisition noise. 35 features based on intensity histograms (IH), co-occurrence matrices (COM), neighborhood-difference matrices (NDM), and zone-size matrices (ZSM) were evaluated within lesions (13, 17, 22, 28, 33 mm diameter). Variability in metrics across 50 independent images was evaluated as percent difference from mean for three phantom girths (850, 1030, 1200 mm) and two OSEM reconstructions (2 iterations, 28 subsets, 5 mm FWHM filtration vs 6 iterations, 28 subsets, 8.6 mm FWHM filtration). Also, patient sample size to detect a clinical effect of 30% with Bonferroni-corrected α=0.001 and 95% power was estimated. Results: As a class, NDM features demonstrated greatest sensitivity in means (5–50% difference for medium girth and reconstruction comparisons and 10–100% for large girth comparisons). Some IH features (standard deviation, energy, entropy) had variability below 10% for all sensitivity studies, while others (kurtosis, skewness) had variability above 30%. COM and ZSM features had complex sensitivities; correlation, energy, entropy (COM) and zone percentage, short-zone emphasis, zone-size non-uniformity (ZSM) had variability less than 5% while other metrics had differences up to 30%. Trends were similar for sample size estimation; for example, coarseness, contrast, and strength required 12, 38, and 52 patients to detect a 30% effect for the small girth case but 38, 88, and 128 patients in the large girth case. Conclusion: The sensitivity of PET textural features to image acquisition and reconstruction parameters is large and feature-dependent. Standards are needed to ensure that prospective trials which incorporate textural features are properly designed to detect clinical endpoints. Supported by NIH grants R01 CA169072, U01 CA148131, NCI Contract (SAIC-Frederick) 24XS036-004, and a research contract from GE Healthcare.

60 APPLIED LIFE SCIENCES↗