Search NASA⌕ Search

SEARCH · Search NASA

Results for “Standard deviation modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Test of lepton flavor universality and search for lepton flavor violation in B → Kℓℓ decays

We present measurements of the branching fractions for the decays B → Kμ + μ - and B → Ke + e - , and their ratio (R K ), using a data sample of 711 fb -1 that contains 772 × 10 6 B$\bar{B}$ events. The data were collected at the Υ(4S) resonance with the Belle detector at the KEKB asymmetric-energy e + e - collider. The ratio R K is measured in five bins of dilepton invariant-mass-squared (q 2 ): q 2 $\epsilon$ (0.1, 4.0), (4.00, 8.12), (1.0, 6.0), (10.2, 12.8) and (> 14.18) GeV 2 /c 4 , along with the whole q 2 region. The R K value for q 2 $\epsilon$ (1.0, 6.0) GeV 2 /c 4 is 1.03$^{+0.28}_{-0.24}$ ± 0.01. The first and second uncertainties listed are statistical and systematic, respectively. All results for RK are consistent with Standard Model predictions. We also measure CP-averaged isospin asymmetries in the same q 2 bins. The results are consistent with a null asymmetry, with the largest difference of 2.6 standard deviations occurring for the q 2 $\epsilon$ (1.0, 6.0) GeV 2 /c 4 bin in the mode with muon final states. The measured differential branching fractions, dB/dq 2 , are consistent with theoretical predictions for charged B decays, while the corresponding values are below the expectations for neutral B decays. We have also searched for lepton-flavor-violating B → Kμ ± e ∓ decays and set 90% confidence-level upper limits on the branching fraction in the range of 10 -8 for B + → K + μ ± e ∓ , and B 0 → K 0 μ ± e ∓ modes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessments of epistemic uncertainty using Gaussian stochastic weight averaging for fluid-flow regression

Here, we use Gaussian stochastic weight averaging (SWAG) to assess the epistemic uncertainty associated with neural-network-based function approximation relevant to fluid flows. SWAG approximates a posterior Gaussian distribution of each weight, given training data, and a constant learning rate. Having access to this distribution, it is able to create multiple models with various combinations of sampled weights, which can be used to obtain ensemble predictions. The average of such an ensemble can be regarded as the 'mean estimation', whereas its standard deviation can be used to construct 'confidence intervals', which enable us to perform uncertainty quantification (UQ) with regard to the training process of neural networks. We utilize representative neural-network-based function approximation tasks for the following cases: (i) a two-dimensional circular-cylinder wake; (ii) the DayMET dataset (maximum daily temperature in North America); (iii) a three-dimensional square-cylinder wake; and (iv) urban flow, to assess the generalizability of the present idea for a wide range of complex datasets. SWAG-based UQ can be applied regardless of the network architecture, and therefore, we demonstrate the applicability of the method for two types of neural networks: (i) global field reconstruction from sparse sensors by combining convolutional neural network (CNN) and multi-layer perceptron (MLP); and (ii) far-field state estimation from sectional data with two-dimensional CNN. We find that SWAG can obtain physically-interpretable confidence-interval estimates from the perspective of epistemic uncertainty. This capability supports its use for a wide range of problems in science and engineering.

97 MATHEMATICS AND COMPUTING↗

Charge fluctuations for particles on a surface exposed to plasma

We develop a stochastic model for the charge fluctuations on a microscopic dust particle resting on a surface exposed to plasma. We find in steady state that the fluctuations are normally distributed with a standard deviation that is proportional to (CT{sub e}){sup 1/2}, where C is the particle-surface capacitance and T{sub e} is the plasma electron temperature. The time for an initially uncharged ensemble of particles to reach the steady state distribution is directly proportional to CT{sub e}.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New NDA Methods for Thorium Fuel Cycle Safeguards (Final Report)

This project developed portable Neutron Resonance Transmission Analysis (pNRTA) as a new non-destructive assay (NDA) method for thorium fuel cycles safeguards and other applications where multiple isotopes must be measured when present together. pNRTA leverages epithermal neutron resonances to assay multiple safeguards-relevant isotopes (e.g., 233 U and 235 U) when they are present together in a sample. Existing techniques are challenged by this task, driving the need for new active interrogation methods. With selected detectors, pNRTA works in high gamma-ray backgrounds from fission and activation products and 232 U progeny expected in thorium fuel cycle samples. This project leveraged a pNRTA system developed at Pacific Northwest National Laboratory (PNNL) and collaboration with the Massachusetts Institute of Technology (MIT). The system uses a commercially available deuterium-tritium (DT) neutron generator at short standoff (2 m). Key achievements in this project included: first-of-a-kind pNRTA quantitative measurements of 233 U oxide samples, an assessment of neutron detector technologies suitable for pNRTA in high gamma-ray background environments, experimentally demonstrating quantitative assay of samples containing 233 U and 235 U, and modeling studies showing the applicability of pNRTA to a wide range of material forms. Further, a custom algorithm was developed at MIT, which provided mean bias of 9% and relative standard deviation of 36% in assaying 233 U, 235 U, 238 U, and 232 Th content in eight measured samples. These outcomes form a solid technical basis for pNRTA as a new promising capability for international safeguards verification that is portable, non-destructive, quantitative, and isotopic specific.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron Magnetic Form Factor GNM Measurement at High Q2 with CLAS12

The neutron magnetic form factor, GnM , is a fundamental quantity that describes how magnetic properties are distributed within a neutron. This measurement provides insights into the internal structure of the neutron. Furthermore, by measuring GnM alongside three other form factors (GnE , GpE , GpM ), we can test the predictions of Quantum Chromodynamics (QCD), which is the fundamental theory governing the strong force that binds quarks and gluons. Additionally, these measurements play a significant role in constraining Generalized Parton Distributions (GPDs) and contribute to determining the angular momentum of the quarks within nucleons. The GnM was measured using the ratio of quasi-elastic e ? n to e ? p scattering from a deuteron target. The measurement covered a range of four-momentum transfer squared, Q2, from 5 to 12 GeV2, using three different beam energies (10.2, 10.4, and 10.6 GeV). The data is compared with previous measurements and several theoretical models. The preliminary results reveal that Gn M exceeds the predictions of the standard dipole parametrization by 12-20%, based on RG-B pass1 data. It is expected that this deviation from the standard dipole parametrization will diminish as we transition to using RG-B pass2 data, aligning GnM more closely with the dipole form factor. The ongoing RG-B pass2 analysis in CLAS12 holds considerable promise for significant improvement. This enhancement is achievable through collaborative efforts aimed at refining tracking efficiency, momentum correction, calibration, and alignment.

Baashen, Lamya↗

Higgs-radion mixing with an enhanced diphoton signal

In the context of warped scenarios in which standard model (SM) fields are allowed to propagate in the bulk, we revisit the possible mixing between the IR localized Higgs field and the radion graviscalar. The phenomenology of the resulting mostly Higgs field does not suffer important deviations with respect to the case in which all the SM is localized in the IR brane (original Higgs-radion mixing scenario). On the contrary, the phenomenology of the mostly radion field can present important differences with respect to the original scenario. At the LHC, the most striking effect is now the possibility of sizable radion decays into photons in a mass range well beyond the ZZ and WW thresholds, not due to dramatically enhanced couplings to photons but to suppressed couplings to massive fields.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searches for new physics at the Tevatron

The Tevatron collider has provided the CDF and D0 experiences with large datasets as input to a rich program of searches for physics beyond the standard model. The results presented here are a partial survey of recent searches conducted by the two collaborations using up to 6 fb{sup -1} of data. The standard model (SM) of particles, despite its remarkable description of experimental data at the elementary particle level, has some deficiencies to explain what is observed in the universe: lack of anti-matter, existence of dark matter, etc. Working at the energy frontier, as was the case at the Tevatron for so many years, gives experimentalists the hope to discover new non-SM particles which would indicate some direction to follow at explaining these SM deficiencies. Over the years, the CDF and D0 experiments have gained experience in the detector responses to all particle types. It allows to look at a large number of different final states searching for deviations from the SM expectations. As the knowledge of detector particle responses becomes more accurate, the complexity of final states can increase. For a given final state signature, the non-observation of deviations from the SM prediction allows to constrain several models at once.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A dual model HU conversion from MRI intensity values within and outside of bone segment for MRI-based radiotherapy treatment planning of prostate cancer

Purpose: The lack of electron density information in magnetic resonance images (MRI) poses a major challenge for MRI-based radiotherapy treatment planning (RTP). In this study the authors convert MRI intensity values into Hounsfield units (HUs) in the male pelvis and thus enable accurate MRI-based RTP for prostate cancer patients with varying tissue anatomy and body fat contents. Methods: T{sub 1}/T{sub 2}*-weighted MRI intensity values and standard computed tomography (CT) image HUs in the male pelvis were analyzed using image data of 10 prostate cancer patients. The collected data were utilized to generate a dual model HU conversion technique from MRI intensity values of the single image set separately within and outside of contoured pelvic bones. Within the bone segment local MRI intensity values were converted to HUs by applying a second-order polynomial model. This model was tuned for each patient by two patient-specific adjustments: MR signal normalization to correct shifts in absolute intensity level and application of a cutoff value to accurately represent low density bony tissue HUs. For soft tissues, such as fat and muscle, located outside of the bone contours, a threshold-based segmentation method without requirements for any patient-specific adjustments was introduced to convert MRI intensity values into HUs. The dual model HU conversion technique was implemented by constructing pseudo-CT images for 10 other prostate cancer patients. The feasibility of these images for RTP was evaluated by comparing HUs in the generated pseudo-CT images with those in standard CT images, and by determining deviations in MRI-based dose distributions compared to those in CT images with 7-field intensity modulated radiation therapy (IMRT) with the anisotropic analytical algorithm and 360° volumetric-modulated arc therapy (VMAT) with the Voxel Monte Carlo algorithm. Results: The average HU differences between the constructed pseudo-CT images and standard CT images of each test patient ranged from −2 to 5 HUs and from 22 to 78 HUs in soft and bony tissues, respectively. The average local absolute value differences were 11 HUs in soft tissues and 99 HUs in bones. The planning target volume doses (volumes 95%, 50%, 5%) in the pseudo-CT images were within 0.8% compared to those in CT images in all of the 20 treatment plans. The average deviation was 0.3%. With all the test patients over 94% (IMRT) and 92% (VMAT) of dose points within body (lower than 10% of maximum dose suppressed) passed the 1 mm and 1% 2D gamma index criterion. The statistical tests (t- and F-tests) showed significantly improved (p ≤ 0.05) HU and dose calculation accuracies with the soft tissue conversion method instead of homogeneous representation of these tissues in MRI-based RTP images. Conclusions: This study indicates that it is possible to construct high quality pseudo-CT images by converting the intensity values of a single MRI series into HUs in the male pelvis, and to use these images for accurate MRI-based prostate RTP dose calculations.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Constraining hadronization mechanisms with Λ c + / D 0 production ratios in Pb–Pb collisions at s NN = 5.02 TeV

The production of prompt $\ Λ^{+}_{c}$ baryons at midrapidity (|y|<0.5) was measured in central (0–10%) and mid-central (30–50%) Pb–Pb collisions at the center-of-mass energy per nucleon–nucleon pair $\sqrt{s_{NN}}$ TeV with the ALICE detector. The results are more precise, more differential in centrality, and reach much lower transverse momentum (p T =1 GeV/c) with respect to previous measurements performed by the ALICE, STAR, and CMS Collaborations in nucleus–nucleus collisions, allowing for an extrapolation down to p T =0. The p T -differential $\ Λ^{+}_{c}$/D 0 ratio is enhanced with respect to the pp measurement for 4 < p T < 8 GeV/c by 3.7 standard deviations (σ), while the p T -integrated ratios are compatible within 1σ. The observed trend is similar to that observed in the strange sector for the Λ/$\ K^{0}_{S}$ ratio. Model calculations including coalescence or statistical hadronization for charm-hadron formation are compared with the data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Learning new physics from data: A symmetrized approach

Thousands of person years have been invested in searches for new physics (NP), the majority of them motivated by theoretical considerations. Yet, no evidence of beyond the Standard Model physics has been found. This suggests that model-agnostic searches might be an important key to explore NP, and help discover unexpected phenomena which can inspire future theoretical developments. A possible strategy for such searches is identifying asymmetries between data samples that are expected to be symmetric within the Standard Model. We propose exploiting neural networks (NNs) to quickly fit and statistically test the differences between two samples. Our method is based on an earlier work, originally designed for inferring the deviations of an observed dataset from that of a much larger reference dataset. We present a symmetric formalism, generalizing the original one, avoiding fine-tuning of the NN parameters and any constraints on the relative sizes of the samples. Our formalism could be used to detect small symmetry violations, extending the discovery potential of current and future particle physics experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Uncertainty Quantification in State Estimation using the Probabilistic Collocation Method

In this study, a new efficient uncertainty quantification technique, probabilistic collocation method (PCM) on sparse grid points is employed to enable the evaluation of uncertainty in state estimation. The PCM allows us to use just a small number of ensembles to quantify the uncertainty in estimating the state variables of power systems. By sparse grid points, the PCM approach can handle large number of uncertain parameters in power systems with relatively lower computational cost, when comparing with classic Monte Carlo (MC) simulations. The algorithm and procedure is outlined and we demonstrate the capability and illustrate the application of PCM on sparse grid points approach on uncertainty quantification in state estimation of the IEEE 14 bus model as an example. MC simulations have also been conducted to verify accuracy of the PCM approach. By comparing the results obtained from MC simulations with PCM results for mean and standard deviation of uncertain parameters, it is evident that the PCM approach is computationally more efficient than MC simulations.

Lin, Guang↗

Precision Measurements of Lifetime and $\bf CP$ Violation Phase in the $\bf B^{0}_{s}$ Meson with the DØ Detector

The Standard Model of Partice Physics (SM) is probably the most successful theory, regarding to his predictions. The SM prediction for $CP$ violation is not enough to explain the overwhelming asymmetry among the matter and anti-matter abundance. Measuring some process where $CP$ violation is different to the one predicted by the SM would be a clear signal for Physics Beyond the Standard Model. The SM prediction for the $CP$ violation phase, $\phi_{s}$, in the $B^{0}_{s}$ meson is practically equal to zero for the current experiments. This means that measuring a deviation from zero in $\phi_{s}$ could be an indication for Physics Beyond the SM. On the other hand, the approximation based on the ``heavy quark symmetry'' let approximated calculations of the fundamental quantities of those hadrons containing a heavy quark, $c,b,t$. These calculations are expressed as expansions on inverse powers of the heavy quark mass in such hadron. This formalism is called `` Heavy Quark Effective Theory'' (HQET), and has been successful predicting some properties of the heavy hadrons. The HQET prediction for the lifetime ratio the $B^{0}_{d}$ and $B^{0}_{s}$ is practically equal to one. So, measuring with good precision the $B^{0}_{s}$ lifetime is also a way to test an approximation based on the SM. In this thesis it is detailed presented the method to measure the $\phi_{s}$ and the lifetime ratio of the $B^{0}_{d}$ and $B^{0}_{s}$, among other quantities, with the DØ located in the Fermi National Accelerator Laboratory, in the United States.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Regime dependence of ice cloud heterogeneity – a convective life‐cycle effect?

Cloud condensate varies on scales smaller than those typically resolved by global weather and climate models. In order to accurately predict the radiative and microphysical process rates representative of the entire model grid box, the effect of the subgrid‐scale heterogeneity of cloud must be taken into account. In this study, observed ice water content retrieved from A‐Train satellite observations is used to explore how spatial ice condensate variability, characterized by the fractional standard deviation (FSD, the standard deviation divided by the mean), varies with cloud regime. FSD is generally lower for overcast cloud scenes, but an additional predictor based on convective activity is needed to capture the high FSD associated with more turbulent clouds and reproduce the observed latitudinal and height variations of FSD. Convective clouds that extend only a few kilometres above the freezing level are likely to be smaller at an earlier stage in their life cycle, and actively growing with a higher FSD. In contrast, more mature clouds reaching the tropopause are larger and generally have a lower variability and smaller FSD. To capture this life‐cycle effect, a new parametrization is tested which uses the ratio of a model's convectively detrained condensate to the existing cloud condensate mass as a proxy for the cloud's convective life stage to highlight areas with enhanced condensate variability. The parametrization is scale‐adaptive, situation‐dependent and captures seasonally varying global patterns and the zonal mean vertical structure of observed ice condensate variability well. Ground‐based observations obtained from five Atmospheric Radiation Measurement sites provide independent confirmation that the parametrization satisfactorily captures condensate variability in high‐altitude ice clouds.

Ahlgrimm, Maike↗

Evaluating the feasibility of using downwind methods to quantify point source oil and gas emissions using continuously monitoring fence-line sensors

The dependable reporting of methane (CH 4 ) emissions from point sources, such as fugitive leaks from oil and gas infrastructure, is important for profit maximization (retaining more hydrocarbons), evaluating climate impacts, assessing CH 4 fees for regulatory programs, and validating CH 4 intensity in differentiated gas programs. Currently, there are disagreements between emissions reported by different quantification techniques for the same sources. It has been suggested that downwind CH 4 quantification methods using CH 4 measurements on the fence line of production facilities could be used to generate emission estimates from oil and gas operations at the site level, but it is currently unclear how accurate the quantified emissions are. To investigate the accuracy of downwind methods, this study uses fence-line simulated data collected during controlled-release experiments as input for a non-standard closed-path eddy covariance (EC), the Gaussian plume inverse model (GPIM), and the backward Lagrangian stochastic (bLs) model in a range of atmospheric conditions. This study's EC attempt was unsuccessful due to data collection and instrumentation issues, resulting in invalid results characterized by underestimated emissions, large negative fluxes, and cospectra/ogives that deviated from their ideal shapes. Consequently, the EC results could not be compared with the GPIM and bLS model. The bLs model demonstrated the highest accuracy for single-release single-point emissions, though it exhibited greater uncertainty than GPIM under multi-release conditions. Across the GPIM and bLs model, the most reliable quantification was achieved with 15 min averaging and a narrow 5° wind sector range. Although EC was limited in this context, future studies should consider employing a standard EC system and further optimizing GPIM and bLs approaches – particularly for complex multi-source scenarios – to enhance quantification accuracy and reduce uncertainty.

03 NATURAL GAS↗

SU-E-T-638: Evaluation and Comparison of Landauer Microstar (OSLD) Readers

Purpose: To evaluate and compare characteristic performance of a new Landauer nanodot Reader with the previous model. Methods: In order to calibrate and test the reader, a set of nanodots were irradiated using a Varian Truebeam Linac. Solid water slabs and bolus were used in the process of irradiation. Calibration sets of nanodots were irradiated for radiation dose ranges: 0 to 10 and 20 to 1000 cGy, using 6MV photons. Additionally, three sets of nanodots were each irradiated using 6MV, 10MV and 15MV beams. For each beam energy, and selected dose in the range of 3 to 1000 cGy, a pair of nanodots was irradiated and three readings were obtained with both readers. Results: The analysis shows that for 3 photon beam energies and selected ranges of dose, the calculated absorbed dose agrees well with the expected value. The results illustrate that the new Microstar II reader is a highly consistent system and that the repeated readings provide results with a reasonably small standard deviation. For all practical purposes, the response of system is linear for all radiation beam energies. Conclusion: The Microstar II nanodot reader is consistent, accurate, and reliable. The new hardware design and corresponding software contain several advantages over the previous model. The automatic repeat reading mechanism, that helps improve reproducibility and reduce processing time, and the smaller unit size that renders ease of transport, are two of such features. Present study shows that for high dose ranges a polynomial calibration equation provides more consistent results. A 3rd order polynomial calibration curve was used to analyze the readings of dosimeters exposed to high dose range radiation. It was observed that the results show less error compared to those calculated by using linear calibration curves, as provided by Landauer system software for all dose ranges.

60 APPLIED LIFE SCIENCES↗

Method of rotation angle measurement in machine vision based on calibration pattern with spot array

We propose a method of rotation angle measurement with high precision in machine vision. An area scan CCD camera, imaging lens, and calibration pattern with a spot array make up the measurement device for measuring the rotation angle. The calibration pattern with a spot array is installed at the rotation part, and the CCD camera is set at a certain distance from the rotation components. The coordinates of the spots on the calibration pattern is acquired through the vision image of the calibration pattern captured by the CCD camera. At the initial position of the calibration pattern, the camera is calibrated with the spot array; the mathematical model of distortion error of the CCD camera is built. With the equation of coordinate rotation measurement, the rotation angle of the spot array is detected. In the theoretic simulation, noise of different levels is added to the coordinates of the spot array. The experiment results show that the measurement device can measure the rotation angle precisely with a noncontact method. The standard deviation of rotation angle measurement is smaller than 3 arc sec. The measurement device can measure both microangles and large angles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Sub-eV scalar dark matter through the super-renormalizable Higgs portal

The Higgs portal of the standard model provides the opportunity for coupling to a very light scalar field {phi} via the super-renormalizable operator {phi}(H{sup {dagger}H}). This allows for the existence of a very light scalar dark matter that has coherent interaction with the standard model particles and yet has its mass protected against radiative corrections. We analyze ensuing constraints from the fifth force measurements, along with the cosmological requirements. We find that the detectable level of the fifth force can be achieved in models with low inflationary scales, and by a certain amount of fine-tuning in the initial deviation of {phi} from its minimum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inclusive search for a highly boosted Higgs boson decaying to a bottom quark-antiquark pair

An inclusive search for the standard model Higgs boson (H) produced with large transverse momentum (pT) and decaying to a bottom quark-antiquark pair (bb¯) is performed using a data set of pp collisions at s=13 TeV collected with the CMS experiment at the LHC. The data sample corresponds to an integrated luminosity of 35.9 fb-1. A highly Lorentz-boosted Higgs boson decaying to bb¯ is reconstructed as a single, large radius jet, and it is identified using jet substructure and dedicated b tagging techniques. The method is validated with Z→bb¯ decays. The Z→bb¯ process is observed for the first time in the single-jet topology with a local significance of 5.1 standard deviations (5.8 expected). For a Higgs boson mass of 125 GeV, an excess of events above the expected background is observed (expected) with a local significance of 1.5 (0.7) standard deviations. The measured cross section times branching fraction for production via gluon fusion of H→bb¯ with reconstructed pT>450 GeV and in the pseudorapidity range -2.5<η<2.5 is 74±48(stat)-10+17(syst) fb, which is consistent within uncertainties with the standard model prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗