At least 1,063 records · Page 59

Development of a Model Correlating Axial HEPA Filter Performance Between Elevated and Standard Conditions

The ASME AG-1 Code specifies minimum rated airflow based on standard cubic feet per minute (SCFM) for axial high efficiency particulate air (HEPA) filters and actual cubic feet per minute (ACFM) for radial HEPA filters with corresponding maximum pressure drop. A quantitative analysis can be performed to demonstrate the variation in filter efficiency and develop a correlation of performance between axial filters subjected to ACFM and SCFM. This study illustrates the variation in filter efficiency of axial HEPA filters subjected to ACFM and SCFM flow rate conditions at varying atmospheric pressures. It also presents the methods used to calculate correction factors to convert filter efficiency and pressure drop from elevated to standard conditions. The Axial Large Scale Test Stand (ALSTS) in the Institute for Clean Energy Technology (ICET) at Mississippi State University has been utilized to control aerosol concentration, flowrate, atmospheric pressure, relative humidity, and temperature. The filter test matrix consists of axial HEPA filters rated at 1,000 and 1,500 CFM with varying filter pack types. Each filter is subjected to varying pressures of 14.70 psi, 13.55 psi, 12.40 psi, and 11.25 psi, temperatures of 70 deg. F, 110 deg. F, and 150 deg. F, and relative humidities of 50% and 80%, resulting in twenty-four unique testing points. The corresponding SCFM flow rates are computed for each point in order to form a comparison. Evaluation of the effects of designating ACFM or SCFM will be based upon the filter efficiencies of generated Dioctyl Phthalate (DOP) particles at a diameter of 0.3 micrometers. The results show filter efficiency decreasing as atmospheric pressure decreases due to increased filter face velocity. A correlation model is developed to convert filter efficiency and pressure drop at elevated conditions to those of standard pressure, relative humidity, and temperature.

42 ENGINEERING↗

Preliminary Evaluation of Loading DOE Standard Canisters in the INL CPP-603 Irradiated Fuel Storage Facility - 20543

This paper looks at the equipment and operations necessary to load United States Department of Energy (DOE)-owned Spent Nuclear Fuel (SNF) into DOE Standard Canisters in the CPP-603 Irradiated Fuel Storage Facility (IFSF) in the Idaho Nuclear Technology and Engineering Center (INTEC) area at Idaho National Laboratory (INL). Two types of fuels are looked at in this evaluation: Advanced Test Reactor (ATR) fuel (uranium-aluminide fuel with aluminum cladding) and Peach Bottom fuel (thorium-uranium carbide fuel in a graphite matrix). The fuel ready for loading would come from fuel storage canisters in the CPP-603 facility. The paper describes the facility, the fuel types, the DOE Standard Canisters, and existing equipment; lists the needed loading operations; reviews facility features and equipment to perform the operations; and then lists the decisions, analyses, designs, demonstrations, and modifications that will be needed to perform the loading of DOE-owned SNF into DOE Standard Canisters in the CPP-603 IFSF. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cracking in first ramp to power of standard versus high thermal conductivity UO2 pellets via internal nuclear heating

Advanced fuel designs that incorporate thinner fuel UO2 pellets interspaced by high thermal conductivity inserts have been proposed, with the primary goals of reducing peak centerline temperatures and temperature gradients across fuel pellets and enhancing heat transfer from the fuel to the coolant. An initial series of experiments has been performed on this design, including laboratory experiments and a series of experiments using the Idaho National Laboratory (INL) Transient Reactor Test (TREAT) Facility, the latter of which compared thermal gradient driven fracture of standard pellet designs with that in the proposed advanced fuel design. Although reducing fracture is not the primary objective of the new fuel design, the lower thermal gradients are expected to reduce fracture, so it can serve as an indicator of the thermal behavior of this fuel in the reactor. The in-reactor tests were conducted at multiple linear heat generation rates and confirm the expected result that fracture in both the standard and advanced fuel pellets occurs during the first ramp to power in standard light-water reactor conditions. Post-irradiation examination of the experiment material was performed and included quantification of the extent of fracture in the fuel pellets. It was found that the advanced-design pellets reduce the extent of fracture in a statistically significant way. This confirms the expected behavior predicted by two-dimensional axisymmetric models of this experiment. This study is an important first experimental confirmation of the efficacy of the proposed inserts for achieving their desired effect on the thermal behavior of the fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

X-Ray Absorption Near Edge Structure And Extended X-Ray Absorption Fine Structure Analysis of Standards And Biological Samples Containing Mixed Oxidation States of Chromium(III) And Chromium(VI)

For the first time a method has been developed for the extended X-ray absorption fine structure (EXAFS) data analyses of biological samples containing multiple oxidation states of chromium. In this study, the first shell coordination and interatomic distances based on the data analysis of known standards of potassium chromate (Cr(VI)) and chromium nitrate hexahydrate (Cr(III)) were investigated. The standards examined were mixtures of the following molar ratios of Cr(VI):Cr(III), 0:1, 0.25:0.75, 0.5:0.5, 0.75:0.25, and 1:0. It was determined from the calibration data that the fitting error associated with linear combination X-ray absorption near edge structure (LC-XANES) fittings was approximately {+-}10% of the total fitting. The peak height of the Cr(VI) pre-edge feature after normalization of the X-ray absorption (XAS) spectra was used to prepare a calibration curve. The EXAFS fittings of the standards were also investigated and fittings to lechuguilla biomass samples laden with different ratios of Cr(III) and Cr(VI) were performed as well. An excellent agreement between the XANES data and the data presented in the EXAFS spectra was observed. The EXFAS data also presented mean coordination numbers directly related to the ratios of the different chromium oxidation states in the sample. The chromium oxygen interactions had two different bond lengths at approximately 1.68 and 1.98 {angstrom} for the Cr(VI) and Cr(III) in the sample, respectively.

09 BIOMASS FUELS↗

Overview of ASME V&V 20-2009 standard for verification and validation in computational fluid mechanics and heat transfer.

The objective of this Standard is the specification of a verification and validation approach that quantifies the degree of accuracy inferred from the comparison of solution and data for a specified variable at a specified validation point. The approach uses the concepts from experimental uncertainty analysis to consider the errors and uncertainties in both the solution and the data. The scope of this Standard is the quantification of the degree of accuracy of simulation of specified validation variables at a specified validation point for cases in which the conditions of the actual experiment are simulated. Consideration of solution accuracy at points within a domain other than the validation points, for example interpolation/extrapolation in a domain of validation, is a matter of engineering judgment specific to each family of problems and is beyond the scope of this Standard.

97 MATHEMATICS AND COMPUTING↗

A new algae technical standards focus group: Summarizing and guiding the algae state of the art

The value proposition of algae technical metrics was the subject of a recent, industry-led, Focus Group interactive discussion. The interactive platform allowed for real time capturing and priority ranking of the topics that are deemed critical challenges for a future successful algae-based bioeconomy. This work ultimately sets the stage for providing guidance, methods, and standard reference materials tailored to respective algae industry segments for the cultivation, processing and marketing of high-quality and safe algae-based products. The group solicits input from the broader algae community on the value proposition and presents a case here to build a consensus around algae-specific metrics. The value proposition of technical standards to the industry is that guidance obtained through these collaborations builds producers' and consumers' trust that algae and algae-derived products are safe, reliable, and may allow for expanded market access, and increased competitiveness and international trade.

59 BASIC BIOLOGICAL SCIENCES↗

Market-driven automotive industry compliance with fuel economy and greenhouse gas standards: Analysis based on consumer choice

This paper explored factors that affect market-driven compliance with both Corporate Average Fuel Economy (CAFE) and greenhouse gas (GHG) standards (together called the National Program) in the United States for phase I 2012–2016 and phase II 2017–2025. We considered a consumer-choice-based simulation approach, using the MA3T model, to estimate the market acceptance of fuel efficiency (FE) technologies and alternative fuel technologies as reflected by new sales of light-duty vehicle (LDV). Because both full and extremely low FE valuations are common in the literature, we use a moderate assumption of a 10-year perceived vehicle lifetime at a 7% annual discount rate in the baseline and include both extreme views (5 years and 15 years) in the sensitivity analysis. The study focuses on market-driven compliance and therefore excludes manufacturers’ cross-subsidization. The model results suggest that the LDV industry is able to comply with both standards even without cross-subsidization and with projected high technology cost, mainly thanks to the multiple credit programs and technology advancements. The compliance robustness, while encouraging, however is based on moderate market assumptions, such as Annual Energy Outlook 2016 Reference oil price projection and moderate FE consumer valuation. Finally, sensitivity analysis results reveal two significant risk factors for compliance: low oil prices and consumers’ FE undervaluation.

54 ENVIRONMENTAL SCIENCES↗

ABSOLUTE FLUX CALIBRATION OF THE IRAC INSTRUMENT ON THE SPITZER SPACE TELESCOPE USING HUBBLE SPACE TELESCOPE FLUX STANDARDS

The absolute flux calibration of the James Webb Space Telescope (JWST) will be based on a set of stars observed by the Hubble and Spitzer Space Telescopes. In order to cross-calibrate the two facilities, several A, G, and white dwarf stars are observed with both Spitzer and Hubble and are the prototypes for a set of JWST calibration standards. The flux calibration constants for the four Spitzer IRAC bands 1-4 are derived from these stars and are 2.3%, 1.9%, 2.0%, and 0.5% lower than the official cold-mission IRAC calibration of Reach et al., i.e., in agreement within their estimated errors of {approx}2%. The causes of these differences lie primarily in the IRAC data reduction and secondarily in the spectral energy distributions of our standard stars. The independent IRAC 8 {mu}m band-4 fluxes of Rieke et al. are about 1.5% {+-} 2% higher than those of Reach et al. and are also in agreement with our 8 {mu}m result.

79 ASTRONOMY AND ASTROPHYSICS↗

Supersymmetric backgrounds to standard model calibration processes at the CERN LHC

One of the first orders of business for LHC experiments after beam turn-on will be to calibrate the detectors using well-understood standard model (SM) processes such as W and Z production and tt production. These familiar SM processes can be used to calibrate the electromagnetic and hadronic calorimeters, and also to calibrate the associated missing transverse energy signal. However, the presence of new physics may already affect the results coming from these standard benchmark processes. We show that the presence of relatively low mass supersymmetry (SUSY) particles may give rise to significant deviations from SM predictions of Z+jets and W+jets events for jet multiplicity {>=}4 or {>=}5, respectively. Furthermore, the presence of low mass SUSY may cause nonstandard deviations to appear in top quark invariant and transverse mass distributions. Thus, effects that might be construed as detector malperformance could in fact be the presence of new physics. We advocate several methods to check when new physics might be present within SM calibration data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Compliance and Verification of Standards and Labeling Programs in China: Lessons Learned

After implementing several energy efficiency standards and labels (30 products covered by MEPS, 50 products covered by voluntary labels and 19 products by mandatory labels), the China National Institute of Standardization (CNIS) is now implementing verification and compliance mechanism to ensure that the energy information of labeled products comply with the requirements of their labels. CNIS is doing so by organizing check testing on a random basis for room air-conditioners, refrigerators, motors, heaters, computer displays, ovens, and self -ballasted lamps. The purpose of the check testing is to understand the implementation of the Chinese labeling scheme and help local authorities establishing effective compliance mechanisms. In addition, to ensure robustness and consistency of testing results, CNIS has coordinated a round robin testing for room air conditioners. Eight laboratories (Chinese (6), Australian (1) and Japanese (1)) have been involved in the round robin testing and tests were performed on four sets of samples selected from manufacturer's production line. This paper describes the methodology used in undertaking both check and round robin testing, provides analysis of testing results and reports on the findings. The analysis of both check and round robin testing demonstrated the benefits of a regularized verification and monitoring system for both laboratories and products such as (i) identifying the possible deviations between laboratories to correct them, (ii) improving the quality of testing facilities, (iii) ensuring the accuracy and reliability of energy label information in order to strength the social credibility of the labeling program and the enforcement mechanism in place.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Climate-Specific Passive Building Standards

Passive design principles (super insulation, airtight envelopes, elimination of thermal bridges, etc.) - pioneered in North America in the 70s and 80s and refined in Europe in the 90s have proven to be universally effective to significantly reduce heating and cooling loads. However, a single, rigid performance metric developed in Germany has led to limited uptake of passive building principles in many regions of the United States. It has also, in many cases, promoted some design decisions that had negative effects on economic feasibility and thermal comfort. This study's main objective is to validate (in a theoretical sense) verifiable, climate-specific passive standards and space conditioning criteria that retain ambitious, environmentally-necessary energy reduction targets and are economically feasible, such standards provide designers an ambitious but achievable performance target on the path to zero.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of German and American fabrication standards for transportation and storage containments of high level radioactive material type B packages - 15055

As the competent authority for the evaluation of German radioactive material (RAM) transport and storage packages, BAM (the German Federal Institute for Materials Research and Testing) has evaluated various international cask manufacturers regarding compliance with the German Type B(U) licensing requirements. The US NRC has recommended paragraphs in the ASME Boiler and Pressure Vessel (B and PV) Code, Section III, Division 3, as the measure to quantify the safety requirements of the US regulations regarding fabrication of RAM transportation and storage containments. The objective of this study is to compare the fabrication criteria of the German Dangerous Goods Procedural Rules (BAM-GGR) and the German Institute for Standardization (DIN) with the US quantitative measures for fabrication of RAM package containment vessels. This comparison will cover major similarities and differences between the requirements of the German standards and the ASME Code requirements for Type B package containment fabrication QC (quality control). While the material most often used for German RAM containment applications is ductile cast iron (DCI), in the US forged austenitic stainless steel is typically used. This study focuses on fabrication QC measures required to ensure reproducible and acceptable properties for DCI containments. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Demand or No Demand: Electrical Rates for Standard 90.1-2010

ASHRAE is developing the 2010 version of Standard 90.1 with the goal of reaching 30% savings beyond the 2004 edition of the standard. Economics are used to inform the process of setting criteria and the assumed electricity rates are crucial to these calculations. Previously the committee used national average electrical rates in the criteria setting but recently a number of voices have been heard in support of using demand rates instead. This article explores the issues surrounding the use of a pure consumption rate vs. the use of demand rates and looks at the implications for HVAC equipment efficiency.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Progress towards Managing Residential Electricity Demand: Impacts of Standards and Labeling for Refrigerators and Air Conditioners in India

The development of Energy Efficiency Standards and Labeling (EES&L) began in earnest in India in 2001 with the Energy Conservation Act and the establishment of the Indian Bureau of Energy Efficiency (BEE). The first main residential appliance to be targeted was refrigerators, soon to be followed by room air conditioners. Both of these appliances are of critical importance to India's residential electricity demand. About 15percent of Indian households own a refrigerator, and sales total about 4 million per year, but are growing. At the same time, the Indian refrigerator market has seen a strong trend towards larger and more consumptive frost-free units. Room air conditioners in India have traditionally been sold to commercial sector customers, but an increasing number are going to the residential sector. Room air conditioner sales growth in India peaked in the last few years at 20percent per year. In this paper, we perform an engineering-based analysis using data specific to Indian appliances. We evaluate costs and benefits to residential and commercial sector consumers from increased equipment costs and utility bill savings. The analysis finds that, while the BEE scheme presents net benefits to consumers, there remain opportunities for efficiency improvement that would optimize consumer benefits, according to Life Cycle Cost analysis. Due to the large and growing market for refrigerators and air conditioners in India, we forecast large impacts from the standards and labeling program as scheduled. By 2030, this program, if fully implemented would reduce Indian residential electricity consumption by 55 TWh. Overall savings through 2030 totals 385 TWh. Finally, while efficiency levels have been set for several years for refrigerators, labels and MEPS for these products remain voluntary. We therefore consider the negative impact of this delay of implementation to energy and financial savings achievable by 2030.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Compliance and Verification of Standards and Labelling Programs in China: Lessons Learned

After implementing several energy efficiency standards and labels (30 products covered by MEPS, 50 products covered by voluntary labels and 19 products by mandatory labels), the China National Institute of Standardization (CNIS) is now implementing verification and compliance mechanism to ensure that the energy information of labeled products comply with the requirements of their labels. CNIS is doing so by organizing check testing on a random basis for room air-conditioners, refrigerators, motors, heaters, computer displays, ovens, and self -ballasted lamps. The purpose of the check testing is to understand the implementation of the Chinese labeling scheme and help local authorities establishing effective compliance mechanisms. In addition, to ensure robustness and consistency of testing results, CNIS has coordinated a round robin testing for room air conditioners. Eight laboratories (Chinese (6), Australian (1) and Japanese (1)) have been involved in the round robin testing and tests were performed on four sets of samples selected from manufacturer?s production line. This paper describes the methodology used in undertaking both check and round robin testing, provides analysis of testing results and reports on the findings. The analysis of both check and round robin testing demonstrated the benefits of a regularized verification and monitoring system for both laboratories and products such as (i) identifying the possible deviations between laboratories to correct them, (ii) improving the quality of testing facilities, (iii) ensuring the accuracy and reliability of energy label information in order to strength the social credibility of the labeling program and the enforcement mechanism in place.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Higher Flavor Symmetries in the Standard Model

Abstract A study of the generalized global flavor symmetries of the Standard Model is initiated. The presence of nonzero triangle diagrams between the U (3) 5 flavor currents and the hypercharge current intertwines them in the form of a higher‐group which mixes the zero‐form flavor symmetries with the one‐form magnetic hypercharge symmetry. This higher symmetry structure greatly restricts the possible flavor symmetries that may remain unbroken in any ultraviolet completion that includes magnetic monopoles. In the context of unification, this implies tight constraints on the combinations of fermion species which may be joined into multiplets. Three of four elementary possibilities are reflected in the classic unification models of Georgi–Glashow, , and Pati–Salam. The final pattern is realized non‐trivially in trinification, which exhibits the sense in which Standard Model Yukawa couplings which violate these flavor symmetries may be thought of as spurions of the higher‐group. Such modifications of the ultraviolet flavor symmetries are possible only if new vector‐like matter is introduced with masses suppressed from the unification scale by the Yukawa couplings.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Importance of Sample Handling and Preparation for Surface Analysis: A Summary of ISO Standard 20579 Part 1, Documenting and Reporting the Handling of Specimens Prior to Analysis

Reliable and reproducible analysis of surfaces is critically dependent on how samples have been collected, handled, and prepared before analysis. Although there are important, well-established general guidelines to minimize unintended alteration of the surfaces to be analyzed, specific handling steps depend on the nature of the samples and information desired. Assessments of the validity and reliability of the results require adequate information about sampling, handling, and processing. ISO standard 20579 part 1 describes the information to be recorded and reported for samples that are prepared or submitted for surface analysis. This paper summarizes elements of the standard, which includes annexes that justify and inform the sample handling processes. Also included is a checklist of information that needs to be recorded and reported and an appendix containing an example of a form that might be used to report the information.

AES↗