Search NASA⌕ Search

SEARCH · Search NASA

Results for “Statistical Modelling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

An Improved Risk Priority Measure for the Management of Project Risk

Monte Carlo-based project risk models are essential tools in project risk management, particularly for large, complex projects in which it is difficult to glean intuitively the importance of individual risks to the overall project. Conventional correlation-based methods for measuring the importance of contributing risks in such models are argued here to be both statistically flawed and unintuitive in the importance metrics they produce. Drawing on and adapting methods more traditionally associated with engineering risk models, Risk Reduction Worth (RRW) is introduced as an importance measure. RRW is shown to be statistically robust and provide an easily interpretable, quantitative measure of the importance of a risk to the overall performance of a project; specifically, measuring the extent to which removal of a risk would improve confidence in project outcomes. To ensure practicality of the method, an approach is described in which RRWs can be produced for all contributing risks based on a single Monte Carlo sample. This is demonstrated through application to a large, complex project risk model from which intuitive risk importance insights provide a robust, transparent basis for the allocation of risk management resources.

Risk↗

Microscopic constraints for the equation of state and structure of neutron stars: A Bayesian model mixing framework

Bayesian model mixing (BMM) is a statistical technique that can combine constraints from different regions of an input space in a principled way. Here we extend our BMM framework for the equation of state (EOS) of strongly interacting matter from symmetric nuclear matter to asymmetric matter, specifically focusing on zero-temperature, charge-neutral, 𝛽-equilibrated matter. We use Gaussian processes (GPs) to infer constraints on the neutron-star matter EOS at intermediate densities from two different microscopic theories: chiral effective-field theory (𝜒⁢EFT) at baryon densities around nuclear saturation, 𝑛 𝐵 ∼ 𝑛 0 , and perturbative QCD at asymptotically high baryon densities, 𝑛 𝐵 ⩾ 20⁢𝑛 0 . The uncertainties of the 𝜒⁢EFT and pQCD EOSs are obtained using the BUQEYE truncation error model. We demonstrate the flexibility of our framework through the use of two categories of GP kernels: conventional stationary kernels and a nonstationary changepoint kernel. We use the latter to explore potential constraints on the dense matter EOS by including exogenous data representing theory predictions and heavy-ion collision measurements at densities ⩾ 2⁢𝑛 0 . We also use our EOSs to obtain neutron-star mass-radius relations and their uncertainties. Finally, our framework, whose implementation will be available through a GitHub repository, provides a prior distribution for the EOS that can be used in large-scale neutron-star inference frameworks.

Bayesian methods↗

Evaluating Tropical Precipitation Relations in CMIP6 Models with ARM Data

Abstract A set of diagnostics based on simple, statistical relationships between precipitation and the thermodynamic environment in observations is implemented to assess phase 6 of the Coupled Model Intercomparison Project (CMIP6) model behavior with respect to precipitation. Observational data from the Atmospheric Radiation Measurement (ARM) permanent field observational sites are augmented with satellite observations of precipitation and temperature as an observational baseline. A robust relationship across observational datasets between column water vapor (CWV) and precipitation, in which conditionally averaged precipitation exhibits a sharp pickup at some critical CWV value, provides a useful convective onset diagnostic for climate model comparison. While a few models reproduce an appropriate precipitation pickup, most models begin their pickup at too low CWV and the increase in precipitation with increasing CWV is too weak. Convective transition statistics compiled in column relative humidity (CRH) partially compensate for model temperature biases—although imperfectly since the temperature dependence is more complex than that of column saturation. Significant errors remain in individual models and weak pickups are generally not improved. The conditional-average precipitation as a function of CRH can be decomposed into the product of the probability of raining and mean precipitation during raining times (conditional intensity). The pickup behavior is primarily dependent on the probability of raining near the transition and on the conditional intensity at higher CRH. Most models roughly capture the CRH dependence of these two factors. However, compensating biases often occur: model conditional intensity that is too low at a given CRH is compensated in part by excessive probability of precipitation.

54 ENVIRONMENTAL SCIENCES↗

Indirect Tool Condition Monitoring Using Ensemble Machine Learning Techniques

Abstract Tool condition monitoring (TCM) has become a research area of interest due to its potential to significantly reduce manufacturing costs while increasing process visibility and efficiency. Machine learning (ML) is one analysis technique which has demonstrated advantages for TCM applications. However, the commonly studied individual ML models lack generalizability to new machining and environmental conditions, as well as robustness to the unbalanced datasets which are common in TCM. Ensemble ML models have demonstrated superior performance in other fields, but have only begun to be evaluated for TCM. As a result, it is not well understood how their TCM performance compares to that of individual models, or how homogeneous and heterogeneous ensemble models’ performances compare to one another. To fill in these research gaps, milling experiments were conducted using various cutting conditions, and the model groups were compared across several performance metrics. Statistical t-tests were also used to evaluate the significance of model performance differences. Through the analysis of four individual ML models and five ensemble models, all based on the processes’ sound, spindle power, and axial load signals, it was found that on average, the ensemble models performed better than the individual models, and that the homogeneous ensembles outperformed the heterogeneous ensembles.

Engineering↗

A Review of Bayesian Networks for Spatial Data

We report Bayesian networks are a popular class of multivariate probabilistic models as they allow for the translation of prior beliefs about conditional dependencies between variables to be easily encoded into their model structure. Due to their widespread usage, they are often applied to spatial data for inferring properties of the systems under study and also generating predictions for how these systems may behave in the future. We review published research on methodologies for representing spatial data with Bayesian networks and also summarize the application areas for which Bayesian networks are employed in the modeling of spatial data. We find that a wide variety of perspectives are taken, including a GIS-centric focus on efficiently generating geospatial predictions, a statistical focus on rigorously constructing graphical models controlling for spatial correlation, as well as a range of problem-specific heuristics for mitigating the effects of spatial correlation and dependency arising in spatial data analysis. Special attention is also paid to potential future directions for integration of Bayesian networks with spatial processes.

97 MATHEMATICS AND COMPUTING↗

Neutrinoless Double-Beta Decay Investigations of 82Se Using Three Shell Model Hamiltonians

Neutrinoless double-beta decay is considered one of the most promising processes that would help clarify some of the symmetry-breaking problems in our understanding of the observable universe. Recent studies of neutrinoless double-beta decay matrix elements have employed statistical approaches based on modified shell model effective Hamiltonians for 48Ca (Phys. Rev. C 106, 054302 (2022)) and 136Xe (Phys. Rev. C 107, 045501 (2023)). The analyses rely on inducing perturbations in the starting effective Hamiltonians to observe the behavior of a wide range of observables, besides the 0νββ) NME, that are compared with experimental data. Following a Bayesian model averaging approach, the range of probable values for the neutrinoless double-beta decay matrix elements is presented. In this paper, we present a similar study for 82Se, which is described in the same model space as 76Ge that is under experimental observation. Due to its faster calculation time compared to 76Ge, 82Se can be used as an appropriate substitute in our complex statistical study. Using the calculations performed for the statistical analysis of the neutrinoless double-beta decay matrix elements, we also search for the correlations between the observables that we can compare to experimental data.

Science & Technology - Other Topics↗

Evaluation and projection of long period return values of extreme daily precipitation in the CMIP5 and CMIP6 models

Using a non-stationary Generalized Extreme Value statistical method, we calculate selected extreme daily precipitation indices and their 20 year return values from the CMIP5 and CMIP6 climate models over the historical and future periods. We evaluate model performance of these indices and their return values in replicating similar quantities calculated from multiple gridded observational products. Difficulties in interpreting model quality in the context of observational uncertainties are discussed. Projections are framed in terms of specified global warming target temperatures rather than at specific times and under specific emissions scenarios. The change in framing shifts projection uncertainty due to differences in model climate sensitivity from the values of the projections to the timing of the global warming target. At their standard resolutions, we find there are no meaningful differences between the two generations of models in their quality or projections of simulated extreme daily precipitation.

54 ENVIRONMENTAL SCIENCES↗

Machine Learning Inference of Random Medium Properties

Earth materials are heterogeneous across a range of spatial scales, but the resolvability of small structures is limited by sparse data coverage, noise, bandlimitedness, and other difficulties. In practice, heterogeneities below a certain size cannot be recovered from seismic data except through statistical medium descriptions, which even then can be difficult to uniquely determine. To improve the characterization of such heterogeneities, we develop a novel supervised machine learning (ML) model that provides insight about the recoverability of statistical medium properties from elastic waveform data and succeeds despite cycle-skipping and other challenges well known from elastic waveform inversion. We demonstrate the approach using random media generated by superimposing self-affine random variations on homogeneous and layered background structures. After training on sparsely-recorded, high-frequency waveforms from hundreds of different random medium realizations, we show the ability of our ML model to recover correlation lengths and other statistical properties of interest to near-surface and crustal seismology, among other fields. For frequency passbands and spatial offsets encountered in seismology, Gaussian correlation lengths and the amplitude of the random variations relative to the background model are recovered even in challenging scenarios involving unknown medium parameters, complex crustal structures, and low signal-to-noise ratio. In comparison, von Kármán correlation lengths, which are related to larger-wavelength variations of the medium than Gaussian correlation lengths, are not as well recovered. These results provide one of the first and most systematic investigations of the recoverability of statistical properties of heterogeneities below the resolution limit of deterministic seismic tomography, and suggest practical ML strategies for high-frequency waveform seismology.

58 GEOSCIENCES↗

Initial Atmospheric Transport of Particles

A new version of the Initial Atmospheric Transport (IAT) model has been developed. This report fully characterizes the new model. IAT is designed to model heat release into the atmosphere that contains contaminated particles. The heat release forms a buoyant puff or plume. Buoyancy is quickly dissipated in 10's to 100's of seconds through drag and entrainment of ambient air. The final location of contaminant particles in the atmosphere after dissipation of abnormal heat is an important input to long term transportation codes such as the National Oceanic and Atmospheric Administration's (NOAA) Hybrid Single Particle Lagrangian Integrated Trajectory (HYSPLIT) code. Ultimately the settling of contaminants after long term transport provides a basis for estimating health consequences. In comparison to the old version, the new model includes explicit simulation of particles, newly formulated equations of motion for a rising puff, and a new plume model. The plume model releases many instances of a single puff along a single trajectory in a way that balances energy released over a longer period than would be appropriate for a single puff. The puff model has additions for vorticity, turbulence, virtual mass, drag, and entrainment. The particle model leads to direct interfacing between IAT and the long-term transport code HYSPLIT. Previously, particle locations were given a pattern based on IAT's puff trajectory with no particle simulation. Now, particles are explicitly simulated, and 3-D spatial distributions of particles are output based on final positions. Ballistic particles are thrown outward at high velocity from explosive events and tend to hit the ground before the end of the simulation. Non-ballistic particles tend to get pulled into the rising puff s ring of vorticity with some escaping to ambient conditions as buoyant energy dissipates. A new model verification and validation effort was made for the new plume model. The Wallops Island Solid Rocket Propellant (SRP) fire plume was extracted to a 3-D transient dataset. After calibration, the model performs better than previous single puff attempts. Even so, error levels in the process used to estimate location and ambient weather conditions approach 30%. This leads to the conclusion that unplanned photogrammetry evaluations of the IAT model are useful but not sufficiently accurate to quantify model parameters. Like previous attempts, the vertical motion entrainment parameters come out much too high in comparison to values for other studies in the literature. It is suspected that a new model of shear entrainment would alleviate this problem. Unfortunately, IAT already has more calibration parameters than the data comparisons thus far can resolve with statistical certainty. This underscores the need to verify and validate the IAT model using detailed CFD studies that allow ideal statistical comparison with the IAT model for hundreds of cases. Even so, validation by comparison to carefully planned experiments (i.e. with acceptable error levels) is also necessary because the dynamics of entrainment are at a sub-grid level for CFD. Though better validation and verification are most important, many new enhancements are still envisioned for future IAT development. These include particle rain out due to condensation and agglomeration of water, direct connection to the North American Mesoscale (NAM) weather dataset, dynamic weather conditions, including ambient particle entrainment into the puff, and detrainment at the puff to ambient mixing interface. In general, including detailed aerosol dynamics is the greatest coming challenge which will require an entire new sub-model in IAT. This is very important if contaminant particles change in such a way that they increase or decrease in their potential harm to the environment.

54 ENVIRONMENTAL SCIENCES↗

Measurements of Beam Spin Asymmetries in p+p0 and p´p0 Dihadron Production at CLAS12

Semi-Inclusive Deep Inelastic Scattering (SIDIS) is a powerful experimental tool for studying the internal structure and dynamics of the proton, revealing how quarks and gluons are distributed and interact within it. SIDIS describes a process where an elec tron scatters off one of the constituent quarks within the proton, causing it to undergo hadronization, creating multiple hadrons in the final state. Through factorization, the full process can be split into probabilistic components: one which describes the internal structure of the proton using Parton Distribution Functions (PDFs), and another which describes the hadronization process using Fragmentation Functions (FFs). These functions are non-perturbative quantities of Quantum Chromodynamics (QCD), meaning they cannot be calculated directly from first principles and must instead be extracted from experimental measurements. Acommon approach for accessing PDFs and FFs using SIDIS is to measure asymmetries. In this context, asymmetries correspond to subtle differences in the angular distribution of outgoing particles that arise when the spin orientation of the incoming beam or target is reversed. Because many of these effects only appear when spin is involved, they isolate specific, nuanced properties of the proton’s spin-structure that are otherwise hidden in spin averaged measurements. In practice, they show up as specific azimuthal modulations (e.g., sin ¿R, sin(¿h ´ ¿R)), whose amplitudes isolate convolutions of PDFs and FFs at leading and subleading twist. Non-zero asymmetries of these angular distributions can be traced back to unique combinations of PDFs and FFs, offering a way to probe them directly. In this work, we measure SIDIS by analyzing high energy electron-proton scattering events using the CLAS12 detector at Jefferson Lab. This study focuses on subset of SIDIS referred to as dihadron SIDIS, where pairs of hadrons — here p+p0 and p´p0 — are observed. We analyzed these dihadrons using detector data collected during Fall 2018 and Spring 2019, where longitudinally polarized electrons from the CEBAF accelerator were incident on a liquid hydrogen target. A photon classifier using a Gradient Boosted Trees (GBTs) architecture was trained using Monte Carlo simulations to reduce the amount of iv false combinatorial background p0’s. When deployed on experimental data, the model in creases our dihadron statistics by up to five-fold compared to previous CLAS12 p0 analyses. This work reports the first measurements of beam spin asymmetries for p+p0 and p´p0 dihadron production in SIDIS. The measured asymmetries offer new insights to the spin-dependent structure and dynamics within the proton, as well as the spin-dependent properties of quark fragmentation. Non-zero twist-3 sin¿R amplitudes are observed, pro viding sensitivity to the subleading twist PDF e(x). The PDF e(x) encodes quark-gluon correlations within the proton — a property that is otherwise inaccessible at leading twist. Additionally, this work measured significant twist-2 modulations carried by sin(¿h ´ ¿R) and sin(2¿h ´2¿R), providing experimental access to the helicity dihadron fragmentation function (DiFF) GK 1 . Because there is no equivalent quark helicity-dependent FF in single pion SIDIS, the DiFF GK 1 offers a unique lens into novel spin-dependent fragmentation. For instance, the twist-2 modulations observed in this study are enhanced by vector mesons created during fragmentation — a behavior predicted by phenomenological models. This study broadens our understanding of dihadron fragmentation, revealing new details about the flavor and charge dependence of hadronization.

Matousek, Gregory [Duke Univ., Durham, NC (United ↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: LED Lighting

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a timeseries profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - LED lighting. The LED lighting measure replaces interior lights with LEDs where applicable. The measure resulted in 1.25 TBtu energy savings across the building stock, with the majority of savings occurring in retail and warehouse buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Economizers

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Natural Gas Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock (™) and ComStock (™) models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - boiler replacement with air-source heat pump boiler with natural gas boiler backup. This measure replaces natural gas boilers for HVAC application by air-source heat pump boilers when applicable and use natural gas boiler backup when the heat pump boiler could not operate due to outdoor air conditions which are below its cutoff temperature. This measure helps to quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 3. The total natural gas energy consumption was reduced by 41%, whereas the total electricity consumption was increased by 5.3%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Upgrade Package Documentation: Wall and Roof Insulation and New Windows

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Window Replacement, Exterior Wall Insulation, and Roof Insulation, which we will refer to collectively as the "High Efficiency Envelope" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

ComStock Measure Documentation: High-Efficiency Rooftop Unit

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - high-efficiency rooftop unit (RTU) - and briefly introduces key results. The full public data set can be accessed on the Comstock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Measure Documentation: Variable-Speed Pumps

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - variable speed pumps - and briefly introduces key results. The full public data set can be accessed on the ComStock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗