Search NASA⌕ Search

SEARCH · Search NASA

Results for “System control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Implementation of a High-Speed Multichannel Data Acquisition System for Magnetic Diagnostics and Plasma Centroid Position Control in ISTTOK

In tokamak and other fusion devices, magnetic control is the main tool that allows to regulate the plasma current, position and shape; it is in charge of actuating the desired plasma current waveform, steering the plasma position to a given set point and maintain the plasma shape close to a prescribed plasma equilibrium. This work describes the application of several physics concepts and computational tools in order to obtain a novel optimal controller for the plasma centroid position, which has been implemented and tested in the real-time plasma control system at the ISTTOK tokamak. A key point for the development of the new control system was the installation of a recently upgraded hardware, that numerically integrates in real-time the magnetic probes signals.

poloidal field coils↗

SNS Resonance Control Cooling Systems and Quadrupole Magnet Cooling Systems DIW Chemistry

This report focuses on control of the water chemistry for the Spallation Neutron Source (SNS) Resonance Control Cooling System (RCCS)/Quadrupole Magnet Cooling System (QMCS) deionized water (DIW) cooling loops. Proper cooling-water chemistry is essential to preserving the DTL and CCL structures during their design lifetime. Appropriate water chemistry will protect cooling-water passages and brazed joints of the structure from erosion, corrosion, and fouling. The RCCS/QMCS DIW chemistry is managed by sidestreams built into the cooling loops; chemicals are not used. Data collected from spring 2013 through spring 2016 are discussed, and an operations regime is recommended. During the evaluation period, the pH, dissolved oxygen, and water resistivity of the cooling water were observed. The data were collected by instruments mounted on mobile chemistry carts, which were moved from one RCCS/QMCS DIW skid to another. During data reading, operational corrections were done on the polishing loops to improve the water chemistry regime. Therefore some trends changed over time. It was found that the RCCS operates with an average pH of 7.24 for all lines (from 7.0 to 7.5, slightly alkaline), the average low dissolved oxygen is in the area of < 36 ppb, and the main loop average resistivity of is > 14 MΩ-cm. The QMCS was found to be operating in a similar regime, with a pH of about 7.5 (slightly alkaline), low dissolved oxygen in the area of < 45 ppb, and main loop resistivity of 10 to 15 MΩ-cm. It is recommended that the cooling loops operate in a regime in which the water has a resistivity that is as high as achievable, a dissolved oxygen concentration that is as low as achievable, and a neutral or slightly alkaline pH. An RCCS/QMCS chemistry guidance document published in May 2017 describes and standardizes the methods and practices for water chemical treatment for the SNS RCCS and QMCS. It is very difficult to accurately measure the pH, dissolved oxygen, and water resistivity in highly pure water. Therefore, a regularly scheduled calibration program will be established for the instruments. Recommendations are given at the end of the report on how to run the RCCS/QMCS cooling water chemistry. Chemical analysis of the material trapped by the polishing loop prefilters is conducted twice a year. The analysis and its benefits are described in Chapter 9.

42 ENGINEERING↗

Method for rapid development of additive manufacturing parameter set

An apparatus includes a control system that defines a test part having multiple features of multiple feature types. The control system controls an additive manufacturing (AM) machine to print multiple copies of the test part, with each copy being printed according to a respective set of values used as printing parameters. A measurement system obtains a computed tomography (CT) image of each of the copies of the test part. An analysis system, for each of the plurality of feature types, analyzes the CT images to identify a selected set of values for the printing parameters. The analysis system identifies a portion of the CT image related to a first feature and assesses its density based on an average grayscale value. The AM machine is then controlled to print production parts according to, for each feature type of the production parts, the selected set of values for the printing parameters.

Bhattad, Pradeep↗

PC/104 Embedded IOCs at Jefferson Lab

Jefferson Lab has developed embedded IOCs based on PC/104 single board computers (SBC) for low level control systems. The PC/104 IOCs run EPICS on top of the RTEMS operating system. Two types of control system configurations are used in different applications, PC/104 SBC with commercial PC/104 I/O cards and PC/104 SBC with custom designed FPGA-based boards. RTEMS was built with CEXP shell to run on the PC/104 SBC. CEXP shell provides the function of dynamic object loading, which is similar to the widely used VxWorks operating system. Standard software configurations were setup for PC/104 IOC application development to provide a familiar format for new projects as well as ease the conversion of applications from VME based IOCs to PC/104 IOCs. Many new projects at Jefferson Lab are going to employ PC/104 SBCs as IOCs and some applications have already been running them for accelerator operations. The PC/104 - RTEMS IOC provides a free open source Real-Time Operating System (RTOS), low cost/maintenance, easily installed/ configured, flexible, and reliable solution for accelerator control and 12GeV Upgrade projects.

43 PARTICLE ACCELERATORS↗

Payload interposer (PIP) system and control software

A payload interposer (PIP) system and its control software provide an interface between a space vehicle and a payload. The PIP board facilitates power and communications between a command and data handler (CDH) of the space vehicle and the payload. A microcontroller of the PIP board may control operation of the payload, format messages between the space vehicle and the payload, and extract data from the payload for downlink via the space vehicle.

42 ENGINEERING↗

A Cybersecurity Event Simulation Tool and Platform

Digital Instrumentation and Control Systems (ICSs) have replaced analog control systems in nuclear power plants raising cybersecurity concerns. To study and understand the cybersecurity risks of nuclear power plants both high fidelity models of the plant physics and controllers must be created, and a framework to test and evaluate cyber security events must be established. A testing and evaluation framework of cybersecurity events consists of a method of interfering with control systems, a simulation of the plant network, and a network packet capture and recording tool. Sandia National Labs (SNL) in collaboration with the University of New Mexico’s Institute for Space and Nuclear Power Studies (UNM-ISNPS) is developing such a cybersecurity testing framework.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Alfalfa [SWR 18-17]

Alfalfa is a web based software service that implements a virtual building control system using the EnergyPlus simulation as a backend. Conventional building energy simulation is non interactive, meaning that a simulation is started and run to completion without any user input during the simulation. Alfalfa allows a client to start a building simulation, then interactively read sensor locations and dynamically command actuators in realtime. The Alfalfa web service conforms to the Project Haystack standard, which is a specification adopted by many building control system vendors. The service enables Haystack compliant control system vendors to test their control modules and algorithms without the need for a physical building or modifying their hardware and software, enabling faster and cheaper development cycles. Alfalfa has use cases beyond control system testing. One example is building fault detection, where physical building performance can be compared to simulated values in realtime, indicating where there may be a problem in the building. Another use case is informing predictive control systems, where near future events are simulated to premptively guide control decisions in the real building. This software is web based and designed to be self service. Users of Alfalfa can upload an OpenStudio building model and begin communicating with the simulated building without any advanced setup or configuration, as if they were communicating a real building control system. Behind the scenes, Alfalfa makes extensive use of Amazon Web Services, in order to scale from a very small number of users and buildings, to extremely large numbers in a cost effective way.

Benne, Kyle↗

Mesoscale system feedback-induced dissipation and noise suppression

A high-gain and low-noise negative feedback control (“feedback control”) system can detect charge transfer in quantum systems at room temperatures. The feedback control system can attenuate dissipative coupling between a quantum system and its thermodynamic environment. The feedback control system can be integrated with standard commercial voltage-impedance measurement system, for example, a potentiostat. In one aspect, the feedback control system includes a plurality of electrodes that are configured to electrically couple to a sample, and a feedback mechanism coupled to a first electrode of the plurality of electrodes. The feedback mechanism is configured to detect a potential associated with the sample via the first electrode. The feedback mechanism provides a feedback signal to the sample via a second electrode of the plurality of electrodes, the feedback signal is configured to provide excitation control of the sample at a third electrode of the plurality of electrode.

Gupta, Chaitanya↗

OPSAID improvements and capabilities report.

Process Control System (PCS) and Industrial Control System (ICS) security is critical to our national security. But there are a number of technological, economic, and educational impediments to PCS owners implementing effective security on their systems. Sandia National Laboratories has performed the research and development of the OPSAID (Open PCS Security Architecture for Interoperable Design), a project sponsored by the US Department of Energy Office of Electricity Delivery and Energy Reliability (DOE/OE), to address this issue. OPSAID is an open-source architecture for PCS/ICS security that provides a design basis for vendors to build add-on security devices for legacy systems, while providing a path forward for the development of inherently-secure PCS elements in the future. Using standardized hardware, a proof-of-concept prototype system was also developed. This report describes the improvements and capabilities that have been added to OPSAID since an initial report was released. Testing and validation of this architecture has been conducted in another project, Lemnos Interoperable Security Project, sponsored by DOE/OE and managed by the National Energy Technology Laboratory (NETL).

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Cyber Security Assessment Report: Adventium Labs

Major control system components often have life spans of 15-20 years. Many systems in our Nation's critical infrastructure were installed before the Internet became a reality and security was a concern. Consequently, control systems are generally insecure. Security is now being included in the development of new control system devices; however, legacy control systems remain vulnerable. Most efforts to secure control systems are aimed at protecting network borers, but if an intruder gets inside the network these systems are vulnerable to a cyber attack.

Source record↗

A View on Future Building System Modeling and Simulation

This chapter presents what a future environment for building system modeling and simulation may look like. As buildings continue to require increased performance and better comfort, their energy and control systems are becoming more integrated and complex. We therefore focus in this chapter on the modeling, simulation and analysis of building energy and control systems. Such systems can be classified as heterogeneous systems because they involve multiple domains, such as thermodynamics, fluid dynamics, heat and mass transfer, electrical systems, control systems and communication systems. Also, they typically involve multiple temporal and spatial scales, and their evolution can be described by coupled differential equations, discrete equations and events. Modeling and simulating such systems requires a higher level of abstraction and modularisation to manage the increased complexity compared to what is used in today's building simulation programs. Therefore, the trend towards more integrated building systems is likely to be a driving force for changing the status quo of today's building simulation programs. Thischapter discusses evolving modeling requirements and outlines a path toward a future environment for modeling and simulation of heterogeneous building systems.A range of topics that would require many additional pages of discussion has been omitted. Examples include computational fluid dynamics for air and particle flow in and around buildings, people movement, daylight simulation, uncertainty propagation and optimisation methods for building design and controls. For different discussions and perspectives on the future of building modeling and simulation, we refer to Sahlin (2000), Augenbroe (2001) and Malkawi and Augenbroe (2004).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of a six-DOF electrodynamic shaker system.

The paper describes the preliminary evaluation of a 6 degree of freedom electrodynamic shaker system. The 8 by 8 inch (20.3 cm) table is driven by 12 electrodynamic shakers producing motion in all 6 rigid body modes. A small electrodynamic shaker system suitable for small component testing is described. The principal purpose of the system is to demonstrate the technology. The shaker is driven by 12 electrodynamic shakers each with a force capability of about 50 lbs (220 N). The system was developed through an informal cooperative agreement between Sandia National Laboratories, Team Corp. and Spectral Dynamics Corporation. Sandia provided the laboratory space and some development funds. Team provided the mechanical system, and Spectral Dynamics provided the control system. Spectral Dynamics was chosen to provide the control system partly because of their experience in MIMO control and partly because Sandia already had part of the system in house. The shaker system was conceived and manufactured by TEAM Corp. Figure 1 shows the overall system. The vibration table, electrodynamic shakers, hydraulic pumps, and amplifiers are all housed in a single cabinet. Figure 2 is a drawing showing how the electrodynamic shakers are coupled to the table. The shakers are coupled to the table through a hydraulic spherical pad bearing providing 5 degrees of freedom and one stiff degree of freedom. The pad bearing must be preloaded with a static force as they are unable to provide any tension forces. The horizontal bearings are preloaded with steel springs. The drawing shows a spring providing the vertical preload. This was changed in the final design. The vertical preload is provided by multiple strands of an O-ring material as shown in Figure 4. Four shakers provide excitation in each of the three orthogonal axes. The specifications of the shaker are outlined in Table 1. Four shakers provide inputs in each of the three orthogonal directions. By choosing the phase relationships between the shakers all six rigid body modes (three translation, and three rotations) can be excited. The system is over determined. There are more shakers than degrees of freedom. This provided an interesting control problem. The problem was approached using the input-output transformation matrices provided in the Spectral control system. Twelve accelerometers were selected for the control accelerometers (a tri-axial accelerometer at each corner of the table (see Figure 5). Figure 6 shows the nomenclature used to identify the shakers and control accelerometers. A fifth tri-axial accelerometer was placed at the center of the table, but it was not used for control. Thus we had 12 control accelerometers and 12 shakers to control a 6-dof shaker. The 12 control channels were reduced to a 6-dof control using a simple input transformation matrix. The control was defined by a 6x6 spectral density matrix. The six outputs in the control variable coordinates were transformed to twelve physical drive signals using another simple output transformation matrix. It was assumed that the accelerometers and shakers were well matched such that the transformation matrices were independent of frequency and could be deduced from rigid body considerations. The input/output transformations are shown in Equations 1 and 2.

36 MATERIALS SCIENCE↗

PJM Controller Testing with Prototypic PJM Nozzle Configuration

The U.S. Department of Energy (DOE) Office of River Protection’s Waste Treatment Plant (WTP) is being designed and built to pre-treat and then vitrify a large portion of the wastes in Hanford’s 177 underground waste storage tanks. The WTP consists of three primary facilities—pretreatment, low-activity waste (LAW) vitrification, and high-level waste (HLW) vitrification. The pretreatment facility will receive waste piped from the Hanford tank farms and separate it into a high-volume, low-activity liquid stream stripped of most solids and radionuclides and a much smaller volume of HLW slurry containing most of the solids and most of the radioactivity. Many of the vessels in the pretreatment facility will contain pulse jet mixers (PJM) that will provide some or all of the mixing in the vessels. Pulse jet mixer technology was selected for use in black cell regions of the WTP, where maintenance cannot be performed once hot testing and operations commence. The PJMs have no moving mechanical parts that require maintenance. The vessels with the most concentrated slurries will also be mixed with air spargers and/or steady jets in addition to the mixing provided by the PJMs. Pulse jet mixers are susceptible to overblows that can generate large hydrodynamic forces, forces that can damage mixing vessels or their internal parts. The probability of an overblow increases if a PJM does not fill completely. The purpose of the testing performed for this report was to determine how reliable and repeatable the primary and safety (or backup) PJM control systems are at detecting drive overblows (DOB) and charge vessel full (CVF) conditions. Testing was performed on the ABB 800xA and Triconex control systems. The controllers operated an array of four PJMs installed in an approximately 13 ft diameter × 15 ft tall tank located in the high bay of the Pacific Northwest National Laboratory (PNNL) 336 Building test facility. The PJMs were fitted with 4 inch diameter discharge nozzles representative of the nozzles to be used in the WTP. This work supplemented earlier controller tests done on PJMs with 2 inch nozzles (Bontha et al. 2007). Those earlier tests enabled the selection of appropriate pressure transmitters with associated piping and resulted in an alternate overblow detection algorithm that uses data from pressure transmitters mounted in a water flush line on the PJM airlines. Much of that earlier work was only qualitative, however, due to a data logger equipment failure that occurred during the 2007 testing. The objectives of the current work focused on providing quantitative determinations of the ability of the BNI controllers to detect DOB and CVF conditions. On both control systems, a DOB or CVF is indicated when the values of particular internal functions, called confidence values, cross predetermined thresholds. There are two types of confidence values; one based on a transformation of jet pump pair (JPP) drive and suction pressures, the other based on the pressure in the flush line. In the present testing, we collected confidence levels output from the ABB and Triconex controllers. These data were analyzed in terms of the true and noise confidence peaks generated during multiple cycles of DOB and CVF events. The distributions of peak and noise amplitudes were compared to see if thresholds could be set that would enable the detection of DOB and CVF events at high probabilities, while keeping false detections to low probabilities. Supporting data were also collected on PJM operation, including data on PJM pressures and levels, to provide direct experimental evidence of when PJMs were filling, full, driving, or overblowing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Method for controlling fiber growth in a laser heated pedestal growth system by controlling a laser power output, a pedestal feedstock rate of motion, and a draw rate

One or more embodiments relate to a method for controlling fiber growth and fiber diameter in a laser heated pedestal growth (LHPG) system so as to provide long, continuous single-crystal optical fibers of uniform diameter. The method generally provides three independent parameter feedback controls to control the molten zone height, laser power, and fiber drawing rates simultaneously in order to reduce the mismatch between instantaneous diameter changes and current diameter. The method permits the growth of fibers with non-uniform diameters along the fiber's length. The method also provides the capability to stop the LHPG system, remove the exhausted pedestal feedstock with a second pedestal feedstock, and restart the LHPG system to provide a continuous fiber.

Buric, Michael P.↗

Advanced, Integrated Control for Building Operations to Achieve 40% Energy Saving

We developed and demonstrated a software based integrated advanced building control platform called Smart Energy Box (SEB), which can coordinate building subsystem controls, integrate variety of energy optimization algorithms and provide proactive and collaborative energy management and control for building operations using weather and occupancy information. The integrated control system is a low cost solution and also features: Scalable component based architecture allows to build a solution for different building control system configurations with needed components; Open Architecture with a central data repository for data exchange among runtime components; Extendible to accommodate variety of communication protocols. Optimal building control for central loads, distributed loads and onsite energy resource; uses web server as a loosely coupled way to engage both building operators and building occupants in collaboration for energy conservation. Based on the open platform of SEB, we have investigated and evaluated a variety of operation and energy saving control strategies on Carnegie Mellon University Intelligent Work place which is equipped with alternative cooling/heating/ventilation/lighting methods, including radiant mullions, radiant cooling/heating ceiling panels, cool waves, dedicated ventilation unit, motorized window and blinds, and external louvers. Based on the validation results of these control strategies, they were integrated in SEB in a collaborative and dynamic way. This advanced control system was programmed and computer tested with a model of the Intelligent Workplace's northern section (IW n ). The advanced control program was then installed in the IW n control system; the performance was measured and compared with that of the state of the art control system to verify the overall energy savings great than 40%. In addition advanced human machine interfaces (HMI's) were developed to communicate both with building occupants and the building operator. Lifecycle cost analyses of the advanced building control were performed, and a Building Control System Guide was prepared and published to inform owners, architects, and engineers dealing with new construction or renovation of buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transpiration-purged optical probe: a novel sensor for high temperature harsh environments

Typical control systems that are found in modern power plants must control the many physical aspects of the complex processes that occur inside the various components of the power plant. As detection and monitoring of pollutants becomes increasingly important to plant operation, these control systems will become increasingly complex, and will depend upon accurate monitoring of the concentration levels of the various chemical species that are found in the gas streams. In many cases this monitoring can be done optically. Optical access can also be used to measure thermal emissions and the particulate loading levels in the fluid streams. Some typical environments were optical access is needed are combustion chambers, reactor vessels, the gas and solid flows in fluidized beds, hot gas filters and heat exchangers. These applications all have harsh environments that are at high temperatures and pressures. They are often laden with products of combustion and other fine particulate matter which is destructive to any optical window that could be used to monitor the processes in these environments in order to apply some control scheme over the process. The dust and char that normally collects on the optical surfaces reduces the optical quality and thus impairs the ability of the optical surface to transmit data. Once this has occurred, there is generally no way to clean the optical surface during operation. The probe must be dismounted from the vessel, disassembled and cleaned or replaced, then remounted. This would require the shutdown of the particular component of the plant where optical monitoring is required. This renders the probe ineffective to be used as the monitoring part of any control system application. The components of optical monitoring equipment are usually built in supporting structures that require precise alignment. This is almost always accomplished using fine scale adjustments to specialized mounting hardware that is attached to the reactor vessel. When the temperature of these supporting structures increases due to the high temperature process that is occurring inside the vessel, the optical alignment can often suffer due to the thermal expansion of the mounting structure. This can render them useless especially for gas velocity measurements or other situations where precise optical alignment is required. What is needed is an optical probe that can be inserted into any hazardous environment that will not suffer alignment problems or other failure modes that are related to high temperature dirty environments, and at the same time maintain a clean optical surface through the lifetime of the devise so that it may be continually used for optical inspection or for control system applications. This paper describes details of the construction and the use of a transpiration purged optical probe which mitigates the problems that are outlined above. The transpiration probe may be used as either an emitter or a detector. The probe is implemented in the harsh high temperature environment of the NETL pulsed combustion system where products of combustion and particulate matter have been shown to degrade the performance of a normal optical window. Assessments of combustion heat release are made by monitoring the ultraviolet signatures that are produced by the concentration of OH during a pulsed combustion process. It is shown that these measurements are directly correlated with the pressure within the pulsed combustor. Probe temperature measurements are also presented to show how the probe and its mounting hardware remain at constant temperatures well below the high temperature environment which they monitor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Hierarchical Security Architecture for Cyber-Physical Systems

Security of control systems is becoming a pivotal concern in critical national infrastructures such as the power grid and nuclear plants. In this paper, we adopt a hierarchical viewpoint to these security issues, addressing security concerns at each level and emphasizing a holistic cross-layer philosophy for developing security solutions. We propose a bottom-up framework that establishes a model from the physical and control levels to the supervisory level, incorporating concerns from network and communication levels. We show that the game-theoretical approach can yield cross-layer security strategy solutions to the cyber-physical systems.

47 OTHER INSTRUMENTATION↗