Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Simulations, Modeling and Data Analysis of Parity Violating Electron Scattering Experiments

In the Standard Model (SM) of nuclear and particle physics, parity violation is incorporated through the representation of the weak interaction as a chiral gauge interaction. Only the left-handed components of particles and right-handed components of antiparticles participate in weak interactions in the Standard Model. This implies that parity is asymmetric for the weak interaction. Parity violating electron scattering (PVES) experiments are designed to probe the physics parameters related to the SM, with the possibility to discover physics beyond the SM (BSM) by measuring the parity violating asymmetry ¿¿¿ of longitudinally polarized electrons scattered off unpolarized targets with high precision. This dissertation will be focused on two PVES experiments, the next 208Pb Lead Radius Experiment (PREX-II), and the Measurement of a Lepton-Lepton Electroweak Reaction (MOLLER) experiment, as well as in some small sections, the Calcium Radius Experiment (CREX) and P2 experiment which are also PVES experiments). PREX-II and CREX experiments, performed in Hall A at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), measured ¿¿¿ in the elastic scattering of longitudinally polarized electrons from 208Pb and 48Ca targets to provide a precise model independent determination of the neutron skin thickness of 208Pb and 48Ca nuclei, respectively. The MOLLER experiment, proposed to start in 2027 and also to be performed in Hall A at Jefferson Lab, is to measure ¿¿¿ of longitudinally polarized electrons scattered off unpolarized electrons (Møller scattering) to determine the weak charge of electrons ¿¿¿ and the weak mixing angle ¿¿ with high precision. As for the P2 experiment, which will be performed at the upcoming MESA accelerator in Mainz Germany, it is to measure the weak charge of proton ¿¿¿ using ¿¿¿ in the elastic electron-proton scattering of polarized electrons off unpolarized protons. The final results from the PREX-II experiment are presented as ¿¿¿=550±16 (¿¿¿¿)±8 (¿¿¿¿) parts-per-billion (ppb). Combining the PREX-I and PREX-II results, the neutron skin thickness from PREX experiments is determined as ¿¿-¿¿=0.283±0.071 ¿¿ in 208Pb. This thesis lists the software and computational contribution of the author to these PVES experiments, including writing scripts and software to help with the PREX-II/CREX experiments, analyzing data to provide useful information and systematic uncertainty for the PREX-II experiment, modeling and simulations for the MOLLER, and providing an alternative design of an electronic equipment for the P2 experiment.

Chen, Yufan↗

Simulations, Modeling and Data Analysis of Parity Violating Electron Scattering Experiments

In the Standard Model (SM) of nuclear and particle physics, parity violation is incorporated through the representation of the weak interaction as a chiral gauge interaction. Only the left-handed components of particles and right-handed components of antiparticles participate in weak interactions in the Standard Model. This implies that parity is asymmetric for the weak interaction. Parity violating electron scattering (PVES) experiments are designed to probe the physics parameters related to the SM, with the possibility to discover physics beyond the SM (BSM) by measuring the parity violating asymmetry ¿¿¿ of longitudinally polarized electrons scattered off unpolarized targets with high precision. This dissertation will be focused on two PVES experiments, the next 208Pb Lead Radius Experiment (PREX-II), and the Measurement of a Lepton-Lepton Electroweak Reaction (MOLLER) experiment, as well as in some small sections, the Calcium Radius Experiment (CREX) and P2 experiment which are also PVES experiments). PREX-II and CREX experiments, performed in Hall A at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), measured ¿¿¿ in the elastic scattering of longitudinally polarized electrons from 208Pb and 48Ca targets to provide a precise model independent determination of the neutron skin thickness of 208Pb and 48Ca nuclei, respectively. The MOLLER experiment, proposed to start in 2027 and also to be performed in Hall A at Jefferson Lab, is to measure ¿¿¿ of longitudinally polarized electrons scattered off unpolarized electrons (Møller scattering) to determine the weak charge of electrons ¿¿¿ and the weak mixing angle ¿¿ with high precision. As for the P2 experiment, which will be performed at the upcoming MESA accelerator in Mainz Germany, it is to measure the weak charge of proton ¿¿¿ using ¿¿¿ in the elastic electron-proton scattering of polarized electrons off unpolarized protons. The final results from the PREX-II experiment are presented as ¿¿¿=550±16 (¿¿¿¿)±8 (¿¿¿¿) parts-per-billion (ppb). Combining the PREX-I and PREX-II results, the neutron skin thickness from PREX experiments is determined as ¿¿-¿¿=0.283±0.071 ¿¿ in 208Pb. This thesis lists the software and computational contribution of the author to these PVES experiments, including writing scripts and software to help with the PREX-II/CREX experiments, analyzing data to provide useful information and systematic uncertainty for the PREX-II experiment, modeling and simulations for the MOLLER, and providing an alternative design of an electronic equipment for the P2 experiment.

Chen, Yufan↗

Ion beam sputter target and method of manufacture

A target for use in an ion beam sputtering apparatus made of at least two target tiles where at least two of the target tiles are made of different chemical compositions and are mounted on a main tile and geometrically arranged on the main tile to yield a desired chemical composition on a sputtered substrate. In an alternate embodiment, the tiles are of varied thickness according to the desired chemical properties of the sputtered film. In yet another alternate embodiment, the target is comprised of plugs pressed in a green state which are disposed in cavities formed in a main tile also formed in a green state and the assembly can then be compacted and then sintered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ERK2 dependent signaling contributes to wound healing after a partial-thickness burn

Burn healing is a complex physiological process involving multiple cell activities, such as cell proliferation, migration and differentiation. Although extracellular signal-regulated kinases (ERK) have a pivotal role in regulating a variety of cellular responses, little is known about the individual functions of ERK isoform for healing in vivo. This study investigated the role of ERK2 in burn healing. To assess this, Erk2{sup +/-} mice generated by gene targeting were used. The resultant mice exhibited significant delay in re-epithelization of partial-thickness burns in the skin in comparison to wild-type. An in vitro proliferation assay revealed that keratinocytes from Erk2{sup +/-} mice grew significantly slower than those prepared from wild-type. These results highlight the importance of ERK2 in the process of burn healing.

60 APPLIED LIFE SCIENCES↗

Optical properties of sputtered aluminum on graphite/epoxy composite material

Solar absorptance, emittance, and coating thickness were measured for a range of coating thicknesses from about 400 A to 2500 A. The coatings were sputtered from an aluminum target onto 1-inch-diameter substrates of T300/5209 graphite/epoxy composite material with two different surface textures. Solar absorptance and emittance values for the specimens with the smooth surface finish were lower than those for the specimens with the rough surface finish. The ratio of solar absorptance to emittance was higher for the smooth specimens, increasing from 2 to 4 over the coating thickness range, than for the rough ones, which had a constant ratio of about 1. The solar absorptance and emittance values were dependent on the thickness of the sputtered coating.

Witte, William G., Jr.↗

Choice of a target with metal coating for laser-induced transfer of ultradispersed materials

The ejection of ultradispersed diamond from a metallised target surface irradiated by nano- and subnanosecond laser pulses is experimentally investigated. Several targets with different transparent bases (quartz, polymethylmethacrylate) and absorbing metal coatings (titanium, aluminium) are investigated. The effect of the metal layer thickness and pulse width on the range of energy densities in which the ejection of diamond nanopowder is due to the transverse strain of metal layer is analysed. The heating of the target rear surface from which transfer occurs, in dependence of the target and laser pulse parameters, is estimated. (photonics and nanotechnology)

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Modifications to LEU-Modified Cintichem Process to Allow Processing of Fission-Produced 99 Mo from Up to 750 g of Irradiated Uranium Targets

Eden Radioisotopes, LLC is developing a TRIGA* -sized, 2 MW all-target reactor system licensed from Sandia National Laboratories. This all-target reactor uses up to 60 Argonne-designed annular LEU-foil targets to produce fission-produced 99 Mo. The Eden low-enriched uranium (LEU) target contains ~137 g of uranium and will be irradiated at up to 30 kW, with a target burnup determined by the number of targets processed each week. The annular target utilizes metallic uranium foils 400 mm long by 72 mm wide by 250±25 -µm-thick covered by a thin (10 µm on each face) nickel fission barrier. The foil is placed between two 35 mil aluminum tubes that form the outer and inner walls of the cladding cylinder, which is hydroformed to provide high thermal conductivity within the target. Eden expects to process between three and five targets per process batch, to maintain the process batch 99 Mo inventory at or below 5000 curies to maintain high 99 Mo recovery, within a few hours of discharge from the reactor. Eden expects to meet full U.S. demand by processing 30 targets per week, with each target operated for two weeks at 30 kW. To meet less than full U.S. demand, both the target power and the number of targets processed weekly will be adjusted. With increased 99 Mo production and given the size of U targets processed in a single batch (up to ~750g-U), it is important to identify whether any modifications are needed to the LEU-modified Cintichem process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A FEATURE OF STELLAR DENSITY DISTRIBUTION WITHIN THE TIDAL RADIUS OF GLOBULAR CLUSTER NGC 6626 (M28) IN THE GALACTIC BULGE

Using wide-field J, H, and K{sub s} images obtained with the WIRCam near-infrared camera on the Canada-France-Hawaii Telescope, we investigated the spatial density configuration of stars within the tidal radius of metal-poor globular cluster NGC 6626, which is known to be located near the bulge region and have a thick-disk orbit motion. In order to trace the stellar density around a target cluster, we sorted the cluster's member stars using a mask-filtering algorithm and weighted the stars on the color-magnitude diagram. From the weight-summed surface density map, we found that the spatial density distribution of stars within the tidal radius is asymmetric with distorted overdensity features. The extending overdensity features are likely associated with the effects of the dynamic interaction with the Galaxy and the cluster's space motion. An interesting finding is that the prominent overdensity features extend toward the direction of the Galactic plane. This orientation of stellar density distribution can be interpreted with the result of the disk-shock effect of the Galaxy, previously experienced by the cluster. Indeed, the radial surface density profile accurately describes this overdensity feature with a break in the slope inside the tidal radius. Thus, the observed results indicate that NGC 6626 experienced a strong dynamical interaction with the Galaxy. Based on the result of strong tidal interaction with the Galaxy and previously published results, we discussed possible origins and evolutions of the cluster: (1) the cluster might have formed in satellite galaxies that were merged and created the Galactic bulge region in the early universe, after which time its dynamical properties were modified by dynamical friction, or (2) the cluster might have formed in primordial and rotationally supported massive clumps in the thick disk of the Galaxy.

79 ASTRONOMY AND ASTROPHYSICS↗

Latitudinal variation of wind erosion of crater ejecta deposits on Mars

The characteristics of wind erosion as the dominant process involved in eroding crater ejecta deposits on Mars are studied. Present-day crater formation in mid to high latitudes involves impact into some thickness of aeolian debris, while impact in the equatorial zone is more likely to involve target materials consisting of coarse-grained aeolian lag deposits or even bedrock. Latitudinal variation dominates differences in ejecta emplacement mechanisms and probably differences in patterns of wind erosion of ejecta and surrounding intercrater materials. Escarpments develop as the deposits are eroded back toward crater rims. Erosion only takes places at escarpment edges where surface roughness may be low enough to allow particle entrainment. Preferential preservation of ejecta emplaced in thick debris may occur. An empirical model developed for wind erosion of ejecta deposits in nonmantled areas suggests that removal of ejecta materials on the average is exceedingly slow. Results suggest high differential aeolian erosion rates that are a function of both grain sizes and large-scale surface roughness.

Arvidson, R. E.↗

High precision 5 MeV Mott polarimeter

We report on the design and performance of a Mott polarimeter optimized for a nominal 5-MeV electron beam from the Continuous Electron Beam Accelerator Facility (CEBAF) injector. The rf time structure of this beam allows the use of time of flight in the scattered electron detection, making it possible to cleanly isolate those detected electrons that originate from the scattering foil, and resulting in measured scattering asymmetries which are exceptionally stable over a broad range of beam conditions, beam currents, and foil thicknesses. In two separate series of measurements from two different photocathode electron sources, we have measured the Mott scattering asymmetries produced by an approximately 86% transversely polarized electron beam incident on ten gold foils with nominal thicknesses between 50 and 1000 nm. The statistical uncertainty of the measured asymmetry from each foil is below 0.25%. Within this statistical precision, the measured asymmetry was unaffected by ±1-mm shifts in the beam position on the target foil, and by beam current changes and dead-time effects over a wide range of beam currents. The overall uncertainty of our beam polarization measurement, arising from the uncertainty in the value of the scattering asymmetry at zero foil thickness as determined from our fits to the measured asymmetries versus scattering foil thicknesses, the estimated systematic effects, and the (dominant) uncertainty from the calculation of the theoretical Sherman function, is 0.61%. A simulation of the polarimeter using geant4 has confirmed that double scattering in the target foil is the sole source of the dependence of the measured asymmetry on foil thickness, and gives a result for the asymmetry versus foil thickness in good agreement with both our measurements and a simple calculation. Future measurements at different beam energies and with target foils of different atomic numbers will seek to bound uncertainties from small effects such as radiative corrections to the calculation of the polarimeter analyzing power. A simultaneous high-precision measurement of the beam polarization with a different polarimeter, AESOP (Accurate Electron Spin Optical Polarimeter), under development at the University of Nebraska, clearly possible at the CEBAF accelerator, will allow a high-precision comparison of our measured asymmetries with theoretical calculations of the Mott analyzing power. Finally, the improved precision of the current Mott polarimeter along with similar improvements to other Jefferson Lab polarimeters warrants another precision comparison of all of these polarimeters when measuring a beam of the same polarization.

Grames, J. M. (ORCID:0000000193908752)↗

Deposition of zinc films by laser method

Conditions of laser irradiation of a zinc target under which large droplets of a laser target material are not formed in the erosion plume are found, and zinc nanofilms with a minimum number of large particles on the surface are produced. The surface structure, thickness and optical characteristics of zinc films are determined as functions of the power density of laser radiation falling on a zinc target. The evaporation threshold for a zinc target irradiated by nanosecond laser pulses is found. (laser technologies)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom

Purpose: MRI is increasingly being used for radiotherapy planning, simulation, and in-treatment-room motion monitoring. To provide more detailed temporal and spatial MR data for these tasks, we have recently developed a novel self-gated (SG) MRI technique with advantage of k-space phase sorting, high isotropic spatial resolution, and high temporal resolution. The current work describes the validation of this 4D-MRI technique using a MRI- and CT-compatible respiratory motion phantom and comparison to 4D-CT. Methods: The 4D-MRI sequence is based on a spoiled gradient echo-based 3D projection reconstruction sequence with self-gating for 4D-MRI at 3 T. Respiratory phase is resolved by using SG k-space lines as the motion surrogate. 4D-MRI images are reconstructed into ten temporal bins with spatial resolution 1.56 × 1.56 × 1.56 mm{sup 3}. A MRI-CT compatible phantom was designed to validate the performance of the 4D-MRI sequence and 4D-CT imaging. A spherical target (diameter 23 mm, volume 6.37 ml) filled with high-concentration gadolinium (Gd) gel is embedded into a plastic box (35 × 40 × 63 mm{sup 3}) and stabilized with low-concentration Gd gel. The phantom, driven by an air pump, is able to produce human-type breathing patterns between 4 and 30 respiratory cycles/min. 4D-CT of the phantom has been acquired in cine mode, and reconstructed into ten phases with slice thickness 1.25 mm. The 4D images sets were imported into a treatment planning software for target contouring. The geometrical accuracy of the 4D MRI and CT images has been quantified using target volume, flattening, and eccentricity. The target motion was measured by tracking the centroids of the spheres in each individual phase. Motion ground-truth was obtained from input signals and real-time video recordings. Results: The dynamic phantom has been operated in four respiratory rate (RR) settings, 6, 10, 15, and 20/min, and was scanned with 4D-MRI and 4D-CT. 4D-CT images have target-stretching, partial-missing, and other motion artifacts in various phases, whereas the 4D-MRI images are visually free of those artifacts. Volume percentage difference for the 6.37 ml target ranged from 5.3% ± 4.3% to 10.3% ± 5.9% for 4D-CT, and 1.47 ± 0.52 to 2.12 ± 1.60 for 4D-MRI. With an increase of respiratory rate, the target volumetric and geometric deviations increase for 4D-CT images while remaining stable for the 4D-MRI images. Target motion amplitude errors at different RRs were measured with a range of 0.66–1.25 mm for 4D-CT and 0.2–0.42 mm for 4D-MRI. The results of Mann–Whitney tests indicated that 4D-MRI significantly outperforms 4D-CT in phase-based target volumetric (p = 0.027) and geometric (p < 0.001) measures. Both modalities achieve equivalent accuracy in measuring motion amplitude (p = 0.828). Conclusions: The k-space self-gated 4D-MRI technique provides a robust method for accurately imaging phase-based target motion and geometry. Compared to 4D-CT, the current 4D-MRI technique demonstrates superior spatiotemporal resolution, and robust resistance to motion artifacts caused by fast target motion and irregular breathing patterns. The technique can be used extensively in abdominal targeting, motion gating, and toward implementing MRI-based adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-G-201-14: Is Maximum Skin Dose a Reliable Metric for Accelerated Partial Breast Irradiation with Brachytherapy?

Purpose: To evaluate the reliability of the maximum point dose (Dmax) to the skin surface as a dosimetric constraint, we investigated the correlation between Dmax at the skin surface and dose metrics at various definitions of skin thickness. Methods: 42 patients treated with APBI using a Strut Adjusted Volume Implant (SAVI) applicator between 2010 and 2014 were retrospectively reviewed. Target (PTV-EVAL) and organs at risk (OARs: skin, lung, and ribs) were delineated on a CT following NSABP B-39 guidelines. Six skin structures were contoured: a rind 3cm external to the body surface and 1, 2, 3, 4, and 5mm thick rinds deep to the body surface. Inverse planning simulated annealing optimization was used to deliver 32–34Gy in 8-10 fractions to the target while minimizing OAR doses. Dmax, D0.1cc, D1.0cc, and D2.0cc to the various skin structures were calculated. Linear regressions between the metrics were evaluated using the coefficient of determination (R{sup 2}). Results: The average±SD PTV-EVAL volume and cavity-to-skin distances were 71.1±28.5cc and 6.9±5.0mm. The target V90 and V95 were 97.3±2.3% and 95.1±3.2%. The Dmax to the skin structures were 78.7±10.2% (skin surface), 82.2±10.7% (skin-1mm), 89.4±12.6% (skin-2mm), 97.9±15.4% (skin-3mm), 114.1±32.5% (skin-4mm), and 157.0±85.3% (skin-5mm). Linear regression analysis showed D1.0cc and D2.0cc to the skin 1mm and Dmax to the skin-4mm and 5mm were poorly correlated with other metrics (R{sup 2}=0.413±0.204). Dmax to the skin surface was well correlated (R{sup 2}=0.910±0.047) and D1.0cc to the skin-3mm was strongly correlated with all subsurface skin layers (R{sup 2}=0.935±0.050). Conclusion: Dmax to the skin surface is a relevant metric for breast skin dose. Contouring discontinuities in the skin with a 1mm subsurface rind and the active dwells in the skin 4 and 5mm introduced significant variations in skin DVH. D0.1cc, D1.0cc, and D2.0cc to a 3mm skin rind are more robust metrics in breast brachytherapy.

60 APPLIED LIFE SCIENCES↗

Experimental evidence for short-pulse laser heating of solid-density target to high bulk temperatures

Heating efficiently solid-density, or even compressed, matter has been a long-sought goal in order to allow investigation of the properties of such state of matter of interest for various domains, e.g. astrophysics. High-power lasers, pinches, and more recently Free-Electron-Lasers (FELs) have been used in this respect. Here we show that by using the high-power, high-contrast “PEARL” laser (Institute of Applied Physics-Russian Academy of Science, Nizhny Novgorod, Russia) delivering 7.5J in a 60 fs laser pulse, such coupling can be efficiently obtained, resulting in heating of a slab of solid-density Al of 0.8µm thickness at a temperature of 300eV, and with minimal density gradients. The characterization of the target heating is achieved combining X-ray spectrometry and measurement of the protons accelerated from the Al slab. The measured heating conditions are consistent with a three-temperatures model that simulates resistive and collisional heating of the bulk induced by the hot electrons. Such effective laser energy deposition is achieved owing to the intrinsic high contrast of the laser which results from the Optical Parametric Chirped Pulse Amplification technology it is based on, allowing to attain high target temperatures in a very compact manner, e.g. in comparison with large-scale FEL facilities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Angular distributions of reflected and refracted relativistic electron beams crossing a thin planar target at a small angle to its surface

The scattering of electrons by aluminum, copper, and lead foils, as well as by bimetallic aluminum-lead and aluminum-copper foils, has been studied experimentally. A microtron with an energy of particles of 7.4 MeV has been used as a source of electrons. The beam of particles incident on a target at small angles is split into particles reflected from the foil, which constitute a reflected beam, and particles crossing the foil, which constitute a refracted beam. The effect of the material and thickness of the foil, as well as the angle between the initial trajectory of the beam and the plane of the target, on the direction of motion and the angular divergence of the beam crossing the foil and the beam reflected from the foil has been analyzed. Furthermore, the effect of the sequence of metal layers in bimetallic films on the angles of refraction and reflection of the beam has been examined.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Advanced-Ignition-Concept Exploration on OMEGA

Advanced ignition concepts, such as fast ignition and shock ignition, are being investigated at the Omega Laser Facility. Integrated fast-ignition experiments with room-temperature re-entrant cone targets have begun, using 18 kJ of 351 nm drive energy to implode empty 40μm thick CD shells, followed by 1.0 kJ of 1053 nm wavelength, short-pulse energy. Short pulses of 10 ps width have irradiated the inside of a hollow gold re-entrant cone at the time of peak compression. A threefold increase in the time-integrated, 2 to 7 keV x-ray emission was observed with x-ray pinhole cameras, indicating that energy is coupled from the short-pulse laser into the core by fast electrons. In shock-ignition experiments, spherical plastic-shell targets were compressed to high areal densities on a low adiabat, and a strong shock wave was sent into the converging, compressed capsule. In one experiment, 60 beams were used with an intensity spike at the end of the laser pulse, and the implosion performance was studied through neutron-yield and areal-density measurements. In a second experiment, the 60 OMEGA beams were split into a 40+20 configuration, with 40 low-intensity beams used for fuel assembly and 20 delayed beams with a short, high-intensity pulse shape (up to 1×1016 Wcm^-2) for shock generation.

Theobald, W↗

Advanced-Ignition-Concept Exploration on OMEGA

Advanced ignition concepts, such as fast ignition and shock ignition, are being investigated at the Omega Laser Facility. Integrated fast-ignition experiments with room-temperature re-entrant cone targets have begun, using 18 kJ of 351 nm drive energy to implode empty 40μm thick CD shells, followed by 1.0 kJ of 1053 nm wavelength, short-pulse energy. Short pulses of 10 ps width have irradiated the inside of a hollow gold re-entrant cone at the time of peak compression. A threefold increase in the time-integrated, 2 to 7 keV x-ray emission was observed with x-ray pinhole cameras, indicating that energy is coupled from the short-pulse laser into the core by fast electrons. In shock-ignition experiments, spherical plastic-shell targets were compressed to high areal densities on a low adiabat, and a strong shock wave was sent into the converging, compressed capsule. In one experiment, 60 beams were used with an intensity spike at the end of the laser pulse, and the implosion performance was studied through neutron-yield and areal-density measurements. In a second experiment, the 60 OMEGA beams were split into a 40+20 configuration, with 40 low-intensity beams used for fuel assembly and 20 delayed beams with a short, high-intensity pulse shape (up to 1×10 16 Wcm -2 ) for shock generation.

42 ENGINEERING↗

Nanomechanical and topographical imaging of living cells by atomic force microscopy with colloidal probes

Atomic Force Microscopy (AFM) has a great potential as a tool to characterize mechanical and morphological properties of living cells; these properties have been shown to correlate with cells’ fate and patho-physiological state in view of the development of novel early-diagnostic strategies. Although several reports have described experimental and technical approaches for the characterization of cellular elasticity by means of AFM, a robust and commonly accepted methodology is still lacking. Here, we show that micrometric spherical probes (also known as colloidal probes) are well suited for performing a combined topographic and mechanical analysis of living cells, with spatial resolution suitable for a complete and accurate mapping of cell morphological and elastic properties, and superior reliability and accuracy in the mechanical measurements with respect to conventional and widely used sharp AFM tips. We address a number of issues concerning the nanomechanical analysis, including the applicability of contact mechanical models and the impact of a constrained contact geometry on the measured Young’s modulus (the finite-thickness effect). We have tested our protocol by imaging living PC12 and MDA-MB-231 cells, in order to demonstrate the importance of the correction of the finite-thickness effect and the change in Young’s modulus induced by the action of a cytoskeleton-targeting drug.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗