Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

2D-imaging of absolute OH and H 2 O 2 profiles in a He–H 2 O nanosecond pulsed dielectric barrier discharge by photo-fragmentation laser-induced fluorescence

We report pulsed dielectric barrier discharges (DBD) in He–H 2 O and He–H 2 O–O 2 mixtures are studied in near atmospheric conditions using temporally and spatially resolved quantitative 2D imaging of the hydroxyl radical (OH) and hydrogen peroxide (H 2 O 2 ). The primary goal was to detect and quantify the production of these strongly oxidative species in water-laden helium discharges in a DBD jet configuration, which is of interest for biomedical applications such as disinfection of surfaces and treatment of biological samples. Hydroxyl profiles are obtained by laser-induced fluorescence (LIF) measurements using 282 nm laser excitation. Hydrogen peroxide profiles are measured by photo-fragmentation LIF (PF-LIF), which involves photo-dissociating H 2 O 2 into OH with a 212.8 nm laser sheet and detecting the OH fragments by LIF. The H 2 O 2 profiles are calibrated by measuring PF-LIF profiles in a reference mixture of He seeded with a known amount of H 2 O 2 . OH profiles are calibrated by measuring OH-radical decay times and comparing these with predictions from a chemical kinetics model. Two different burst discharge modes with five and ten pulses per burst are studied, both with a burst repetition rate of 50 Hz. In both cases, dynamics of OH and H 2 O 2 distributions in the afterglow of the discharge are investigated. Gas temperatures determined from the OH-LIF spectra indicate that gas heating due to the plasma is insignificant. The addition of 5% O 2 in the He admixture decreases the OH densities and increases the H 2 O 2 densities. The increased coupled energy in the ten-pulse discharge increases OH and H 2 O 2 mole fractions, except for the H 2 O 2 in the He–H 2 O–O 2 mixture which is relatively insensitive to the additional pulses.

hydrogen peroxide↗

Experimental 3-dimensional tracking of the dynamics of a single electron in the Fermilab Integrable Optics Test Accelerator (IOTA)

We present the results of experimental studies on the transverse and longitudinal dynamics of a single electron in the IOTA storage ring. IOTA is a flexible machine dedicated to beam physics experiments with electrons and protons. A method was developed to reliably inject and circulate a controlled number of electrons in the ring. A key beam diagnostic system is the set of sensitive high-resolution digital cameras for the detection of synchrotron light emitted by the electrons. With 60–130 electrons in the machine, we measured beam lifetime and derived an absolute calibration of the optical system. At exposure times of 0.5 s, the cameras were sensitive to individual electrons. Camera images were used to reconstruct the time evolution of oscillation amplitudes of a single electron in all 3 degrees of freedom. The evolution of amplitudes directly showed the interplay between synchrotron-radiation damping, quantum excitations, and scattering with the residual gas. From the distribution of measured single-electron oscillation amplitudes, we deduced transverse emittances, momentum spread, damping times, and beam energy. Estimates of residual-gas density and composition were calculated from the measured distributions of vertical scattering angles. Combining scattering and lifetime data, we also provide an estimate of the aperture of the ring. To our knowledge, this is the first time that the dynamics of a single electron are tracked in all three dimensions with digital cameras in a storage ring.

43 PARTICLE ACCELERATORS↗

Weak lensing measurement of the mass–richness relation of SDSS redMaPPer clusters

Here, we perform a measurement of the mass–richness relation of the redMaPPer galaxy cluster catalogue using weak lensing data from the Sloan Digital Sky Survey. We carefully characterized a broad range of systematic uncertainties, including shear calibration errors, photo-zz biases, dilution by member galaxies, source obscuration, magnification bias, incorrect assumptions about cluster mass profiles, cluster centering, halo triaxiality, and projection effects. We then compare measurements of the lensing signal from two independently-produced shear and photometric redshift catalogues to characterize systematic errors in the lensing signal itself. Using a sample of 5,570 clusters from 0.1 ≤ zz ≤ 0.33, the normalization of our power-law mass vs. λ relation is log 10 [M 200m /h -1 M ⊙ ] = 14.344 ± 0.021 (statistical) ±0.023 (systematic) at a richness λ = 40, a 7 per cent calibration uncertainty, with a power-law index of 1.33+0.09-0.101.33$+0.09\atop{-0.10}$ (1σ). Finally, the detailed systematics characterization in this work renders it the definitive weak lensing mass calibration for SDSS redMaPPer clusters at this time.

79 ASTRONOMY AND ASTROPHYSICS↗

Bell state optimizations for reliable quantum applications

Well-defined and stable quantum networks are essential to realize functional quantum communication applications. In particular, the quantum states must be precisely controlled to produce meaningful results. To counteract the unstable phase shifts in photonic systems, we apply local Bell state measurements to calibrate a non-local quantum channel. The calibration procedure is tested by applying a time encoded quantum key distribution procedure using entangled photons.

Dasari, Venkat↗

Fractionated stereotactic radiotherapy: A method to evaluate geometric and dosimetric uncertainties using radiochromic films

In the authors' hospital, stereotactic radiotherapy treatments are performed with a Varian Clinac 600C equipped with a BrainLAB m3 micro-multileaf-collimator generally using the dynamic conformal arc technique. Patient immobilization during the treatment is achieved with a fixation mask supplied by BrainLAB, made with two reinforced thermoplastic sheets fitting the patient's head. With this work the authors propose a method to evaluate treatment geometric accuracy and, consequently, to determine the amount of the margin to keep in the CTV-PTV expansion during the treatment planning. The reproducibility of the isocenter position was tested by simulating a complete treatment on the anthropomorphic phantom Alderson Rando, inserting in between two phantom slices a high sensitivity Gafchromic EBT film, properly prepared and calibrated, and repeating several treatment sessions, each time removing the fixing mask and replacing the film inside the phantom. The comparison between the dose distributions measured on films and computed by TPS, after a precise image registration procedure performed by a commercial piece of software (FILMQA, 3cognition LLC (Division of ISP), Wayne, NJ), allowed the authors to measure the repositioning errors, obtaining about 0.5 mm in case of central spherical PTV and about 1.5 mm in case of peripheral irregular PTV. Moreover, an evaluation of the errors in the registration procedure was performed, giving negligible values with respect to the quantities to be measured. The above intrinsic two-dimensional estimate of treatment accuracy has to be increased for the error in the third dimension, but the 2 mm margin the authors generally use for the CTV-PTV expansion seems adequate anyway. Using the same EBT films, a dosimetric verification of the treatment planning system was done. Measured dose values are larger or smaller than the nominal ones depending on geometric irradiation conditions, but, in the authors' experimental conditions, always within 4%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-120: Dosimetric Characteristics Study of NanoDotâ,,¢ for In-Vivo Dosimetry

Purpose: The purpose of the study was to analyze the dosimetric characteristics (energy dependence, reproducibility and dose linearity) of nanoDot™ optically stimulated luminescence dosimeters (OSLDs) and validate their potential use during in-vivo dosimetry, specifically TBI. The manufacturer stated accuracy is ±10% for standard nanoDot™. Methods: At AKUH, the InLight microStar OSL dosimetry system for patient in-vivo dosimetry is in use since 2012. Twenty-five standard nanoDot™ were used in the analysis. Sensitivity and reproducibility was tested in the first part with 6MV and 18 MV Varian x-ray beams. Each OSLD was irradiated to 100cGy dose at nominal SSD (100 cm). All the OSLDs were read 3 times for average reading. Dose linearity and calibration were also performed with same beams in common clinical dose range of 0 - 500 cGy. In addition, verification of TBI absolute dose at extended SSD (500cm) was also performed. Results: The reproducibility observed with the OSLD was better than the manufacturer stated limits. Measured doses vary less than ±2% in 19(76%) OSLDs, whereas less than ±3% in 6(24%) OSLDs. Their sensitivity was approximately 525 counts per cGy. Better agreement was observed between measurements, with a standard deviation of 1.8%. A linear dose response was observed with OSLDs for both 6 and 18MV beams in 0 - 500 cGy dose range. TBI measured doses at 500 cm SSD were also confirmed to be within ±0.5% and ±1.3% of the ion chamber measured doses for 6 and 18MV beams respectively. Conclusion: The dosimetric results demonstrate that nanoDot™ can be potentially used for in-vivo dosimetry verification in various clinical situations, with a high degree of accuracy and precision. In addition OSLDs exhibit better dose reproducibility with standard deviation of 1.8%. There was no significant difference in their response to 6 and 18MV beams. The dose response was also linear.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP3-01: Better Kerma-Area-Product (KAP) Estimation Using the System Parameters in Radiography and Fluoroscopy

Purpose: Accurate values for Kerma-Area-Product (KAP) are needed for patient dosimetry and quality control for exams utilizing radiographic and/or fluoroscopic imaging. The KAP measured using a typical direct KAP meter built with parallel-plate transmission ionization chamber is not precise and depends on the energy spectrum of diagnostic x-rays. This study compared the accuracy and reproducibility of KAP derived from system parameters with values measured with a direct KAP meter. Methods: IEC tolerance for displayed KAP is specified up to ± 35% above 2.5 Gy-cm{sup 2} and manufacturer’s specifications are typically ± 25%. KAP values from the direct KAP meter drifts with time leading to replacement or re-calibration. More precise and consistent KAP is achievable utilizing a database of known radiation output for various system parameters. The integrated KAP meter was removed from a radiography system. A total of 48 measurements of air kerma were acquired at x-ray tube potential from 40 to 150 kVp with 10 kVp increment using ion chamber type external dosimeter at free-in-air geometry for four different types of filter combinations following the manufacturer’s service procedure. These data were used to create updated correction factors that determine air kerma computationally for given system parameters. Results of calculated KAP were evaluated against results using a calibrated ion chamber based dosimeter and a computed radiography imaging plate to measure x-ray field size. Results: The accuracy of calculated KAP from the system parameters was better within 4% deviation in all diagnostic x-ray tube potentials tested from 50 to 140 kVp. In contrast, deviations of up to 25% were measured from KAP displayed from the direct KAP meter. Conclusion: The “calculated KAP” approach provides the nominal advantage of improved accuracy and precision of displayed KAP as well as reduced cost of calibrating or replacing integrated KAP meters.

60 APPLIED LIFE SCIENCES↗

Camp Fire processed Landsat 8 images, pre-fire, during-fire, post-fire

The Camp Fire rapidly spread across a landscape in Butte County, California, toward the city of Paradise in the early morning hours of 8 November 2018. GEE acquires L8 data products from USGS that include Real-Time Tier 1 DN values, representing scaled, calibrated at-sensor radiance, and Level-1 Precision Terrain (L1TP) processing. We carried out additional processing on the pre- and post-fire images, including an illumination correction to account for effects of steep topography, and radiometric normalization to ensure homogeneity between images. We also identified and processed high-quality images for both the pre-fire condition(25 Oct 2013), and the post-fire burn scar (26 Dec 2018). Using the tools we provided in the paper, we estimate that, over the first hour, the Camp Fire was consuming ~200 ha/minute of vegetation with a linear spread rate of 14 km over the fire’s first 25 minutes, or ~33km/hr. We briefly discuss broader use of remote sensing and geospatial analysis for fire research and risk management. A visualization app (sliderApp) that includes pre-fire, active fire, and post-fire images: https://caralyngorman.users.earthengine.app/view/camp-fire-sliding-map-3-9-19

54 ENVIRONMENTAL SCIENCES↗

Biomass Compositional Analysis: NIR Rapid Methods (Fact Sheet)

NREL biomass analysis scientists use near-infrared (NIR) spectroscopy correlated with compositional data, produced using traditional wet chemical techniques, to develop rapid calibration models. These models dramatically decrease the time required for (and the cost of) routine compositional analyses. NREL has models to predict the composition of a variety of biomass types.

09 BIOMASS FUELS↗

Fall 2016 Solicitation Projects Website Info

Spark-ignition engines are the backbone behind people transportation around the world. The efficiency of spark-ignition engines is limited in practice by variations between engine cycles and cylinders within an engine that result from the manufacturing processes/tolerances. These variations impact knock limits and dilution tolerance, which results in more conservative settings for design and calibration settings, such as compression ratio, valve timing, and exhaust gas recirculation rates. Engine variations also have a significant impact on emissions generation, which can have a secondary impact on efficiency. A deeper understanding of the relative importance of these variations and their interactions on the charge preparation process can guide future decisions on machining tolerances and control strategies. This project will develop simulation tools and methodology to include the effects of some key manufacturing tolerances and their impact on engine performance and emissions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

CFD Study of Impact of Part-to-Part Variations on Spark-Ignition Engine Charge Formation

Spark-ignition engines are the backbone behind people transportation around the world. The efficiency of spark-ignition engines is limited in practice by variations between engine cycles and cylinders within an engine that result from the manufacturing processes/tolerances. These variations impact knock limits and dilution tolerance, which results in more conservative settings for design and calibration settings, such as compression ratio, valve timing, and exhaust gas recirculation rates. Engine variations also have a significant impact on emissions generation, which can have a secondary impact on efficiency. A deeper understanding of the relative importance of these variations and their interactions on the charge preparation process can guide future decisions on machining tolerances and control strategies. This project will develop simulation tools and methodology to include the effects of some key manufacturing tolerances and their impact on engine performance and emissions.

33 ADVANCED PROPULSION SYSTEMS↗

Fork Experiments in the Hot Cell Using Spent Fuel Rods for International Nuclear Safeguards

This work leveraged the rare availability of 25 full-length pressurized water reactor spent fuel rods and 1 irradiated mixed-oxide rod at an Oak Ridge National Laboratory hot cell. This was done to collect measurement data with two Fork detectors to assess the detectors’ capability of verifying operator declaration data and detecting partial defects in spent fuel, which are the two primary goals of international safeguards on spent nuclear fuel. The data can also be used to benchmark the ORIGEN module, which has been adopted in the International Atomic Energy Agency’s (IAEA’s)/European Atomic Energy Community’s (Euratom’s) Integrated Review and Analysis Program to predict the Fork detector count rates in real time. In this project, the authors first calibrated two Fork detectors—a standard one and a modified one—by using known strong neutron and gamma sources. Then, the authors measured all 26 fuel rods at multiple locations along the length. The fuel rods were then assembled into three arrays—2 × 2, 3 × 3, and 5 × 5—by using specially designed support grids to mimic fuel assemblies and measure the arrays with both detectors. For the 5 × 5 array, 4 and 8 fuel rods of the array were replaced in two separate cases with short stainless-steel rods to mimic two partial defect scenarios, and the arrays were measured before and after the replacements. Polyethylene blocks were used in this experiment to mimic water. The results show that the Fork detectors were able to verify operator declarations and detect partial defects in spent fuel, and the authors were the first to demonstrate this through experiments. A discovery was also made that determined the root cause of the nonlinear response to gamma dose in the ion chambers used in IAEA and Euratom’s Fork detectors. After the experiments, both detectors were retrieved from the hot cell for future use. The data collected in this project will be used in a parallel International Nuclear Safeguards Engagement Program (INSEP) project to enhance the safeguards in the Finnish spent fuel encapsulation plant, and the data will be useful to other projects in the future given the increased safeguards needs due to spent fuel transfer and disposal activities worldwide.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Extend an innovative HPC-Compatible Multiple Temporal-spatial Resolution Concurrent Finite Element Modeling Approach to Guide Laser Powder Bed Fusion Additive

Laser power bed fusing (PBF) additive manufacturing is a key enabling technology to manufacture highly complex and integrated automotive structures. However, the geometric complexity of PBF-AM technique also leads to highly non-uniform heating and cooling rate in the manufactured part, which may cause flaw formation and produce excessive and nonuniform residual stresses, which increase quality uncertainties and manufacture issues, leading to increases in cost and energy consumption in the form of rejected parts. In this research project, we developed an innovative Multi-Spatial-Temporal-Resolution Finite Element (MUST-FE) method and completed the corresponding high performance computation (HPC) platform-based in-house code, which enables high accuracy prediction of temperature and residual stress fields for component-scale PBF-AM manufacture in efficient computation time. The MUST-FE model is calibrated and validated with a “2D pad” AlSi10Mg experiments by matching the melt pool shape and dimension, and with a “XY-cross” AlSi10Mg experiment by matching the thermal distortion and residual stress. The innovative multi-resolution and concurrent modeling approach adopted in this code ensures accuracy and computational efficiency, which will enable energy-efficient and high-yield, low-cost manufacturing of optimized, qualifiable automotive structures and contribute towards reaching technical targets outlined in AMO’s Program Plan to develop additive manufacturing systems that deliver consistently reliable parts with predictable properties.

36 MATERIALS SCIENCE↗

Methodology for Digital Image Correlation and Infrared Measurement of Melting Aluminum Bars

Ultimately, our experiment measures two quantities on an aluminum bar: motion (which modeling must predict) and temperature (which sets thermal boundary conditions). For motion, stereo DIC is a technique to use imaging data to provide displacements relative to a reference image down to 1/100th of a pixel. We use a calibrated infrared imaging method for accurate temperature measurements. We will be capturing simultaneous data and then registering temperature data in space to the same coordinate system as the displacement data. While we will later show that our experiments are repeatable, indicating that separate experiments for motion and temperature would provide similar data, the simultaneous and registered data removes test to test variability as a source of uncertainty for model calibration and reduces the number of time-consuming tests that must be performed.

36 MATERIALS SCIENCE↗

Applying Linear Optics from Closed Orbits Modulation for finding beam-based alignment of harmonic sextupoles

A fast and accurate beam-based alignment (BBA) method for harmonic sextupoles has been devel oped at NSLS-II using Linear Optics from Closed Orbit Modulation (LOCOM). The approach excites the beam with simultaneous sine-wave signals at two fast correctors, chosen with an appropriate phase advance to span the full betatron phase space. This strategy suppresses systematic errors from hysteresis, while additional errors from orbit drift and power-supply calibration are minimized by the short measurement time (a few minutes) and reliance solely on beam-based current-to-field conver sion of the sextupoles, with hysteresis explicitly included. Simulations indicate that Linear Optics from Closed Orbits (LOCO) combined with 0.5 mm local orbit bumps can resolve relative sextupole field offsets (∆k₂) with precision better than 10% of k₂, reflecting to beam-based alignment (BBA) accuracy finer than 50 µm. Moreover, employing machine-learning-optimized local orbit bumps en hances sextupole-induced quadrupole signals in a deterministic manner and maintains orbit stability under large sextupole strength variations (±40%). The proposed method is experimentally validated through proof-of-principle measurements at NSLS-II, demonstrating its potential as a fast, precise, and robust tool for harmonic sextupole alignment.

43 PARTICLE ACCELERATORS↗

The Third Data Release of the KODIAQ Survey

We present and make publicly available the third data release (DR3) of the Keck Observatory Database of Ionized Absorption toward Quasars (KODIAQ) survey. KODIAQ DR3 consists of a fully reduced sample of 727 quasars at 0.1 < z {sub em} < 6.4 observed with the Echellette Sepctrograph and Imager at moderate resolution (4000 ≤ R ≤ 10,000). DR3 contains 872 spectra available in flux calibrated form, representing a sum total exposure time of ∼2.8 megaseconds. These coadded spectra arise from a total of 2753 individual exposures of quasars taken from the Keck Observatory Archive (KOA) in raw form and uniformly processed using a data reduction package made available through the XIDL distribution. DR3 is publicly available to the community, housed as a higher level science product at the KOA and in the igmspec database.

74 ATOMIC AND MOLECULAR PHYSICS↗

Photospheric Emission in the Joint GBM and Konus Prompt Spectra of GRB 120323A

GRB 120323A is a very intense short gamma -ray burst (GRB) detected simultaneously during its prompt γ -ray emission phase with the Gamma-ray Burst Monitor (GBM) on board the Fermi Gamma-ray Space Telescope and the Konus experiment on board the Wind satellite. GBM and Konus operate in the keV–MeV regime; however, the GBM range is broader toward both the low and the high parts of the γ -ray spectrum. Analyses of such bright events provide a unique opportunity to check the consistency of the data analysis as well as cross-calibrate the two instruments. We performed time-integrated and coarse time-resolved spectral analysis of GRB 120323A prompt emission. We conclude that the analyses of GBM and Konus data are only consistent when using a double-hump spectral shape for both data sets; in contrast, the single hump of the empirical Band function, traditionally used to fit GRB prompt emission spectra, leads to significant discrepancies between GBM and Konus analysis results. Our two-hump model is a combination of a thermal-like and a non-thermal component. We interpret the first component as a natural manifestation of the jet photospheric emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Water Vapor Isotopic Composition from the ARM ENA Site, March 2018-March 2019

Humidity and water vapor &delta;D and &delta;18O measurements were collected for a period of one year (March 1, 2018 to February 28, 2019) at the Department of Energy Atmospheric Radiation Measurement facility on Graciosa Island, Azores. Continuous in-situ measurements were collected in the boundary layer using a Los Gatos Research Triple Water Vapor Isotope Analyzer. Stable Isotope measurements were corrected for humidity-induced bias, calibrated to international standards, accounted for time-drift, and are presented as 3-hour averages.

54 ENVIRONMENTAL SCIENCES↗