Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

PETSc Users Manual (Rev. 3.4)

This manual describes the use of PETSc for the numerical solution of partial differential equations and related problems on high-performance computers. The Portable, Extensible Toolkit for Scientific Computation (PETSc) is a suite of data structures and routines that provide the building blocks for the implementation of large-scale application codes on parallel (and serial) computers. PETSc uses the MPI standard for all message-passing communication. PETSc includes an expanding suite of parallel linear, nonlinear equation solvers and time integrators that may be used in application codes written in Fortran, C, C++, Python, and MATLAB (sequential). PETSc provides many of the mechanisms needed within parallel application codes, such as parallel matrix and vector assembly routines. The library is organized hierarchically, enabling users to employ the level of abstraction that is most appropriate for a particular problem. By using techniques of object-oriented programming, PETSc provides enormous flexibility for users. PETSc is a sophisticated set of software tools; as such, for some users it initially has a much steeper learning curve than a simple subroutine library. In particular, for individuals without some computer science background, experience programming in C, C++ or Fortran and experience using a debugger such as gdb or dbx, it may require a significant amount of time to take full advantage of the features that enable efficient software use. However, the power of the PETSc design and the algorithms it incorporates may make the efficient implementation of many application codes simpler than “rolling them” yourself; For many tasks a package such as MATLAB is often the best tool; PETSc is not intended for the classes of problems for which effective MATLAB code can be written. PETSc also has a MATLAB interface, so portions of your code can be written in MATLAB to “try out” the PETSc solvers. The resulting code will not be scalable however because currently MATLAB is inherently not scalable; and PETSc should not be used to attempt to provide a “parallel linear solver” in an otherwise sequential code. Certainly all parts of a previously sequential code need not be parallelized but the matrix generation portion must be parallelized to expect any kind of reasonable performance. Do not expect to generate your matrix sequentially and then “use PETSc” to solve the linear system in parallel. Since PETSc is under continued development, small changes in usage and calling sequences of routines will occur. PETSc is supported; see the web site http://www.mcs.anl.gov/petsc for information on contacting support. A http://www.mcs.anl.gov/petsc/publications may be found a list of publications and web sites that feature work involving PETSc. We welcome any reports of corrections for this document.

97 MATHEMATICS AND COMPUTING↗

PETSc Users Manual (Rev. 3.5)

This manual describes the use of PETSc for the numerical solution of partial differential equations and related problems on high-performance computers. The Portable, Extensible Toolkit for Scientific Computation (PETSc) is a suite of data structures and routines that provide the building blocks for the implementation of large-scale application codes on parallel (and serial) computers. PETSc uses the MPI standard for all message-passing communication. PETSc includes an expanding suite of parallel linear, nonlinear equation solvers and time integrators that may be used in application codes written in Fortran, C, C++, Python, and MATLAB (sequential). PETSc provides many of the mechanisms needed within parallel application codes, such as parallel matrix and vector assembly routines. The library is organized hierarchically, enabling users to employ the level of abstraction that is most appropriate for a particular problem. By using techniques of object-oriented programming, PETSc provides enormous flexibility for users. PETSc is a sophisticated set of software tools; as such, for some users it initially has a much steeper learning curve than a simple subroutine library. In particular, for individuals without some computer science background, experience programming in C, C++ or Fortran and experience using a debugger such as gdb or dbx, it may require a significant amount of time to take full advantage of the features that enable efficient software use. However, the power of the PETSc design and the algorithms it incorporates may make the efficient implementation of many application codes simpler than “rolling them” yourself. ;For many tasks a package such as MATLAB is often the best tool; PETSc is not intended for the classes of problems for which effective MATLAB code can be written. PETSc also has a MATLAB interface, so portions of your code can be written in MATLAB to “try out” the PETSc solvers. The resulting code will not be scalable however because currently MATLAB is inherently not scalable; and PETSc should not be used to attempt to provide a “parallel linear solver” in an otherwise sequential code. Certainly all parts of a previously sequential code need not be parallelized but the matrix generation portion must be parallelized to expect any kind of reasonable performance. Do not expect to generate your matrix sequentially and then “use PETSc” to solve the linear system in parallel. Since PETSc is under continued development, small changes in usage and calling sequences of routines will occur. PETSc is supported; see the web site http://www.mcs.anl.gov/petsc for information on contacting support. A http://www.mcs.anl.gov/petsc/publications may be found a list of publications and web sites that feature work involving PETSc. We welcome any reports of corrections for this document.

97 MATHEMATICS AND COMPUTING↗

Fourier functional analysis for unsteady aerodynamic modeling

A method based on Fourier analysis is developed to analyze the force and moment data obtained in large amplitude forced oscillation tests at high angles of attack. The aerodynamic models for normal force, lift, drag, and pitching moment coefficients are built up from a set of aerodynamic responses to harmonic motions at different frequencies. Based on the aerodynamic models of harmonic data, the indicial responses are formed. The final expressions for the models involve time integrals of the indicial type advocated by Tobak and Schiff. Results from linear two- and three-dimensional unsteady aerodynamic theories as well as test data for a 70-degree delta wing are used to verify the models. It is shown that the present modeling method is accurate in producing the aerodynamic responses to harmonic motions and the ramp type motions. The model also produces correct trend for a 70-degree delta wing in harmonic motion with different mean angles-of-attack. However, the current model cannot be used to extrapolate data to higher angles-of-attack than that of the harmonic motions which form the aerodynamic model. For linear ramp motions, a special method is used to calculate the corresponding frequency and phase angle at a given time. The calculated results from modeling show a higher lift peak for linear ramp motion than for harmonic ramp motion. The current model also shows reasonably good results for the lift responses at different angles of attack.

Lan, C. Edward↗

Fourier functional analysis for unsteady aerodynamic modeling

A method based on Fourier analysis is developed to analyze the force and moment data obtained in large amplitude forced oscillation tests at high angles of attack. The aerodynamic models for normal force, lift, drag, and pitching moment coefficients are built up from a set of aerodynamic responses to harmonic motions at different frequencies. Based on the aerodynamic models of harmonic data, the indicial responses are formed. The final expressions for the models involve time integrals of the indicial type advocated by Tobak and Schiff. Results from linear two- and three-dimensional unsteady aerodynamic theories as well as test data for a 70-degree delta wing are used to verify the models. It is shown that the present modeling method is accurate in producing the aerodynamic responses to harmonic motions and the ramp type motions. The model also produces correct trend for a 70-degree delta wing in harmonic motion with different mean angles-of-attack. However, the current model cannot be used to extrapolate data to higher angles-of-attack than that of the harmonic motions which form the aerodynamic model. For linear ramp motions, a special method is used to calculate the corresponding frequency and phase angle at a given time. The calculated results from modeling show a higher lift peak for linear ramp motion than for harmonic ramp motion. The current model also shows reasonably good results for the lift responses at different angles of attack.

Chin, Suei↗

Exciton dynamics in individual semimagnetic (Zn,Mn)Te/(Zn,Mg)Te nanowires

Dynamics and mechanisms of photocreated carriers decay in individual core/shell (Zn,Mn)Te/(Zn,Mg)Te semimagnetic nanowires are studied with a high temporal resolution. Exciton lifetime determined to 44 ± 5 ps is found to increase to 78 ± 5 ps upon application of magnetic field of up to 10 T. A quantitative modeling attributes the effects observed in time-resolved and time-integrated micro-photoluminescence to the magnetic field induced quenching of exchange Auger type, non-radiative carrier recombination related to Mn{sup 2+} ions. The reported properties of the semimagnetic nanowires are promising for their implementation in high-speed devices exploiting light-induced conductivity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neural Networks for Nuclear Reactions in MAESTROeX

We demonstrate the use of neural networks to accelerate the reaction steps in the MAESTROeX stellar hydrodynamics code. A traditional MAESTROeX simulation uses a stiff ODE integrator for the reactions; here, we employ a ResNet architecture and describe details relating to the architecture, training, and validation of our networks. Our customized approach includes options for the form of the loss functions, a demonstration that the use of parallel neural networks leads to increased accuracy, and a description of a perturbational approach in the training step that robustifies the model. We test our approach on millimeter-scale flames using a single-step, 3-isotope network describing the first stages of carbon fusion occurring in Type Ia supernovae. We train the neural networks using simulation data from a standard MAESTROeX simulation, and show that the resulting model can be effectively applied to different flame configurations. This work lays the groundwork for more complex networks, and iterative time-integration strategies that can leverage the efficiency of the neural networks.

79 ASTRONOMY AND ASTROPHYSICS↗

The Splitting of Double-component Active Asteroid P/2016 J1 (PANSTARRS)

We present deep imaging observations, orbital dynamics, and dust-tail model analyses of the double-component asteroid P/2016 J1 (J1-A and J1-B). The observations were acquired at the Gran Telescopio Canarias (GTC) and the Canada–France–Hawaii Telescope (CFHT) from mid-March to late July of 2016. A statistical analysis of backward-in-time integrations of the orbits of a large sample of clone objects of P/2016 J1-A and J1-B shows that the minimum separation between them occurred most likely ∼2300 days prior to the current perihelion passage, i.e., during the previous orbit near perihelion. This closest approach was probably linked to a fragmentation event of their parent body. Monte Carlo dust-tail models show that those two components became active simultaneously ∼250 days before the current perihelion, with comparable maximum loss rates of ∼0.7 and ∼0.5 kg s{sup −1}, and total ejected masses of 8 × 10{sup 6} and 6 × 10{sup 6} kg for fragments J1-A and J1-B, respectively. Consequently, the fragmentation event and the present dust activity are unrelated. The simultaneous activation times of the two components and the fact that the activity lasted 6–9 months or longer, strongly indicate ice sublimation as the most likely mechanism involved in the dust emission process.

79 ASTRONOMY AND ASTROPHYSICS↗

Greenhouse production contributes to pesticide occurrences in Swedish streams

Greenhouse and other covered cultivation systems have increased globally over the past several decades, leading to considerably improved product quality and productivity per land area unit. However, there is a paucity in information regarding the environmental impacts of covered production systems, especially regarding pesticides entering the surrounding environment. Aiming to address this knowledge gap, we collected grab samples downstream of greenhouses from seven Swedish streams every 14 days during a 12 month period. In three of the streams, samples were also taken upstream of the greenhouses and in four of the streams time-integrated samples were collected by TIMFIE samplers in the period between grab sampling occasions. The samples were analyzed for 28 substances (27 that were permitted for use in greenhouse production systems in Sweden and one degradation product to a permitted substance). Pesticide use journals were collected from the greenhouse producers for the 12 month period. The results were examined for indications of greenhouse contributions to detection frequencies, maximum and average concentrations, and potential ecotoxicicity in several ways: (1) comparing locations downstream of greenhouses with registered use of a substance with those without registered use, (2) comparing results from this study with those from the Swedish environmental monitoring program of pesticides in surface water from catchments with no greenhouses from the same period and region, (3) comparing concentration trends with registered pesticide application times in the greenhouses, and (4) comparing up- and downstream concentrations. The results strongly suggest that greenhouse applications do contribute to pesticide occurrences, maximum and median concentrations for most of the pesticides included in this study, and to potential toxicity to aquatic organisms for several of them, most notably imidacloprid, acetamiprid, carbendazim, and pirimicarb.

54 ENVIRONMENTAL SCIENCES↗

Gamma-Ray Imaging to Monitor Accumulating Holdup

Over time, nuclear materials can accumulate in process equipment and keeping track of such material is of interest to many stakeholder communities including safeguards, process monitoring, criticality safety, and radiological safety. Passive gamma-ray imaging provides a visual and quantitative tool that can be applied to this problem, allowing one to determine the amount of material present from the images. In this work we emulate the accumulation of highly enriched uranium (HEU) in a large rectangular stainless-steel duct by stacking 5, 27 × 50 cm2 cards, each of which has approximately 11 g of 235U in oxide form distributed across its surface, behind each other. A series of images were collected using a coded-aperture gamma-ray imager, starting with a single card, adding a second card, etc. Long integrations were collected to allow evaluating the performance of the approach as a function of integration time. The images are analyzed using first principles to determine the amount of material in each image. The results are compared to the known amount of material in each configuration, and as a function of time. The analysis includes a first-principles error propagation and to further evaluate the uncertainty, a boot-strap sampling approach is also applied to the data. The work offers a proof of concept for unattended monitoring of uranium holdup with a quantitative gamma-ray imaging technique.

Ziock, Klaus-Peter↗

Performance of a Biomass Boiler in a Load Profile Test

In this report, results are presented of the performance evaluation of a modern residential cordwood-fired hydronic heater. This unit was tested under a specific load and operating profile that includes cold start, four load levels, reload, and cycling in response to an emulated thermostat. The protocol can be completed in a single day, which allows for replicate runs in about a week of testing. This can characterize variability with greater confidence than current methods used in certification testing, reduces time to conduct certification tests, and moves toward greater representative operations as the test includes start-up and requires boilers to respond to a variety of heat loads in a manner that better reflects day-to-day operations. Detailed in the report are the results of triplicate testing of one U.S. Environmental Protection Agency-certified cordwood-fired outdoor wood boiler. Cold start emissions were the greatest among all testing periods. In triplicate testing, emission output values for the cold start tests were 9.52, 4.74, and 6.63 lb/MMBtu of output for Test 1, 2, and 3, respectively. The overall emission output values for Test 1, 2, and 3 were 0.44, 0.34, and 0.19 lb/MMBtu of output, respectively. Additionally, the work in this project found significant differences in filter sampling methods with different integrated time periods. The use of real-time particulate matter emission measurement devices was explored. Specifically, sampling with one filter over a long test with various phases (cold starts, reloads, high and low burns) yielded lower particulate mass than sampling phase by phase (one filter for high burns, one filter for low burns, etc.). Perhaps the use of a real-time particulate matter emission measurement device can be used to distinguish different burn phases without having to change filters multiple times throughout a varied load test method

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Global Top-Down Smoke-Aerosol Emissions Estimation Using Satellite Fire Radiative Power Measurements

Fire emissions estimates have long been based on bottom-up approaches that are not only complex, but also fraught with compounding uncertainties. We present the development of a global gridded (1 deg ×1 deg) emission coefficients (Ce) product for smoke total particulate matter (TPM) based on a top-down approach using coincident measurements of fire radiative power (FRP) and aerosol optical thickness (AOT) from the Moderate-resolution Imaging Spectroradiometer (MODIS) sensors aboard the Terra and Aqua satellites. This new Fire Energetics and Emissions Research version 1.0 (FEER.v1) Ce product has now been released to the community and can be obtained from http://feer.gsfc. nasa.gov/, along with the corresponding 1-to-1 mapping of their quality assurance (QA) flags that will enable the Ce values to be filtered by quality for use in various applications. The regional averages of Ce values for different ecosystem types were found to be in the ranges of 16-21/gMJ−1 for savanna and grasslands, 15-32/gMJ−1 for tropical forest, 9-12/gMJ−1 for North American boreal forest, and 18- 26/MJ−1 for Russian boreal forest, croplands and natural vegetation. The FEER.v1 Ce product was multiplied by time-integrated FRP data to calculate regional smoke TPM emissions, which were compared with equivalent emissions products from three existing inventories. FEER.v1 showed higher and more reasonable smoke TPM estimates than two other emissions inventories that are based on bottom-up approaches and already reported in the literature to be too low, but portrayed an overall reasonable agreement with another top-down approach. This suggests that top-down approaches may hold better promise and need to be further developed to accelerate the reduction of uncertainty associated with fire emissions estimation in air-quality and climate research and applications. Results of the analysis of FEER.v1 data for 2004-2011 show that 65-85 Tg yr−1 of TPM is emitted globally from open biomass burning, with a generally decreasing trend over this short time period. The FEER.v1 Ce product is the first global gridded product in the family of "emission factors", that is based essentially on satellite measurements, and requires only direct satellite FRP measurements of an actively burning fire anywhere to evaluate its emission rate in near-real time, which is essential for operational activities, such as the monitoring and forecasting of smoke emission impacts on air quality.

biomass burning↗

The Plasmasphere as "Seen" by the IMAGE Mission

The Imager for Magnetopause-to-Aurora Global Exploration (IMAGE) is the first mission designed exclusively to remotely measure the magnetosphere. As such, it will reveal the ring current, plasmasphere, polar cusp, and magnetopause as whole extended, interacting systems. For the first time, our impressions of the global magnetosphere, synthesized through many years of whistler and in situ measurement, will be replaced by images. The overall morphology of each system of plasma and the correspondence of changes between them in response to the sun and solar wind will become available. The Extreme Ultraviolet Imager (EUV) and the Radio Plasma Imager (RPI) are the two IMAGE instruments which will remotely measure and image the plasmasphere. What we expect to "see" from these instruments and how it may be interpreted is the subject of this presentation. The EUV instrument includes three optical cameras, with an almost 90 degree field of view, transverse to the spin axis. EUV is designed to see He+ ions in resonantly scatter solar light at 30.4rim. The IMAGE spacecraft will spin with a period of about 2 minutes, with its spin axis parallel to the orbit normal. The IMAGE orbit will be highly inclined, with a high latitude apogee at a geocentric distance of 8RE and perigee of about 1.2RE. The normal observing integration time of 10 minutes will easily see to the outer edge of the plasmasphere. The RPI instrument makes use of three orthoganal dipole antennas: two in the spin plane with a tip-to-tip length of 500m and one along the spin axis with a length of 20 meters. Using coded pulse transmissions, the RPI instrument will broadcast from 3kHz to 3MHz. With one minute resolution, plasma densities from about 0.1 cm(exp -3) to 100,000 cm(exp -3), along with line-of-sight bulk velocities and locations, will be obtained from all returned radio wave signals. When transmitting from the high latitude magnetospheric cavity, RPI will measure density profiles for the major plasma structures in the magnetosphere, including the magnetopause, polar cusp, and plasmasphere. RPI should also see isolated density irregularities and possibly the plasma sheet. Observations The EUV instrument will return line-of-sight integrated images through the optically thin helium medium of the plasmasphere and magnetosphere. A variety of techniques have been suggested for the translation of the images into physically useful data, such as plasmapause location and three dimensional density distribution. The RPI instrument will return quantitative density values and line-of-sight velocity as a function of position along reflecting wave propagation paths. How they may be used individually and together to study plasmaspheric dynamics and global structure will be discussed. Attention will also be given to the data products and how access to IMAGE data will be provided by the IMAGE team and the NSSDC.

Gallagher, D. L.↗

An adjoint method for a high-order discretization of deforming domain conservation laws for optimization of flow problems

We report the fully discrete adjoint equations and the corresponding adjoint method are derived for a globally high-order accurate discretization of conservation laws on parametrized, deforming domains. The conservation law on the deforming domain is transformed into one on a fixed reference domain by the introduction of a time-dependent mapping that encapsulates the domain deformation and parametrization, resulting in an Arbitrary Lagrangian–Eulerian form of the governing equations. A high-order discontinuous Galerkin method is used to discretize the transformed equation in space and a high-order diagonally implicit Runge–Kutta scheme is used for the temporal discretization. Quantities of interest that take the form of space–time integrals are discretized in a solver-consistent manner. The corresponding fully discrete adjoint method is used to compute exact gradients of quantities of interest along the manifold of solutions of the fully discrete conservation law. These quantities of interest and their gradients are used in the context of gradient-based PDE-constrained optimization. The adjoint method is used to solve two optimal shape and control problems governed by the isentropic, compressible Navier–Stokes equations. The first optimization problem seeks the energetically optimal trajectory of a 2D airfoil given a required initial and final spatial position. The optimization solver, driven by gradients computed via the adjoint method, reduced the total energy required to complete the specified mission nearly an order of magnitude. The second optimization problem seeks the energetically optimal flapping motion and time-morphed geometry of a 2D airfoil given an equality constraint on the x-directed impulse generated on the airfoil. The optimization solver satisfied the impulse constraint to greater than 8 digits of accuracy and reduced the required energy between a factor of 2 and 10, depending on the value of the impulse constraint, as compared to the nominal configuration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lamb pulse observed in nature

It is shown that seismograms observed at Longmire, Washington, for four eruptions of Mt. St. Helens, those on May 18, June 13, August 7, and August 8, 1980, can be interpreted as Lamb pulses excited by a nearly vertical single force representing the counter force of the eruption. These data furnish reliable estimates of the impulse of the force K (time integral of the force), from which the total momentum and the kinetic energy, E, of the ejecta associated with the eruption can be estimated. The estimates made of K are 1.4 x 10 to the 19th, 1.4 x 10 to the 16th, 3.7 x 10 to the 15th, and 2.8 x 10 to the 15th dynes-sec for the four eruptions (given chronologically). The corresponding estimates for E range from 0.70 to 2.6 x 10 to the 23rd, 0.70 to 2.6 x 10 to the 20th, 1.9 x 10 to the 19th, and 1.4 to 5.3 x 10 to the 19th erg using values of ejecta velocity ranging from 100 to 375 m/sec. The ratio of K to the amplitude of the air wave excited by the eruption is found to be 20 to 40 times larger for the main event on May 18 than for the other events, indicating a significant difference in the eruptive mechanism. A digital seismograph in the vicinity of a volcano is shown to provide a simple means for quantifying the explosive power of a volcanic eruption.

Kanamori, H.↗

Preconditioned conjugate gradient methods for the Navier-Stokes equations

A preconditioned Krylov subspace method (GMRES) is used to solve the linear systems of equations formed at each time-integration step of the unsteady, two-dimensional, compressible Navier-Stokes equations of fluid flow. The Navier-Stokes equations are cast in an implicit, upwind finite-volume, flux-split formulation. Several preconditioning techniques are investigated to enhance the efficiency and convergence rate of the implicit solver based on the GMRES algorithm. The superiority of the new solver is established by comparisons with a conventional implicit solver, namely line Gauss-Seidel relaxation (LGSR). Computational test results for low-speed (incompressible flow over a backward-facing step at Mach 0.1), transonic flow (trailing edge flow in a transonic turbine cascade), and hypersonic flow (shock-on-shock interactions on a cylindrical leading edge at Mach 6.0) are presented. For the Mach 0.1 case, overall speedup factors of up to 17 (in terms of time-steps) and 15 (in terms of CPU time on a CRAY-YMP/8) are found in favor of the preconditioned GMRES solver, when compared with the LGSR solver. The corresponding speedup factors for the transonic flow case are 17 and 23, respectively. The hypersonic flow case shows slightly lower speedup factors of 9 and 13, respectively. The study of preconditioners conducted in this research reveals that a new LUSGS-type preconditioner is much more efficient than a conventional incomplete LU-type preconditioner.

Ajmani, Kumud↗

PETSc/TAO Users Manual (Rev. 3.19)

This manual describes the use of the Portable, Extensible Toolkit for Scientific Computation (PETSc) and the Toolkit for Advanced Optimization (TAO) for the numerical solution of partial differential equations and related problems on high-performance computers. PETSc/TAO is a suite of data structures and routines that provide the building blocks for the implementation of large-scale application codes on parallel (and serial) computers. PETSc uses the MPI standard for all distributed memory communication. PETSc/TAO includes a large suite of parallel linear solvers, nonlinear solvers, time integrators, and opti mization that may be used in application codes written in Fortran, C, C++, and Python (via petsc4py; see Getting Started). PETSc provides many of the mechanisms needed within parallel application codes, such as parallel matrix and vector assembly routines. The library is organized hierarchically, enabling users to employ the level of abstraction that is most appropriate for a particular problem. By using techniques of object-oriented programming, PETSc provides enormous flexibility for users. PETSc is a sophisticated set of software tools; as such, for some users it initially has a much steeper learning curve than packages such as MATLAB or a simple subroutine library. In particular, for individuals without some computer science background, experience programming in C, C++, python, or Fortran and experience using a debugger such as gdb or lldb, it may require a significant amount of time to take full advantage of the features that enable efficient software use. However, the power of the PETSc design and the algorithms it incorporates may make the efficient implementation of many application codes simpler than “rolling them” yourself. For many tasks a package such as MATLAB is often the best tool; PETSc is not intended for the classes of problems for which effective MATLAB code can be written. There are several packages, built on PETSc, that may satisfy your needs without requiring directly using PETSc. We recommend reviewing these packages functionality before starting to code directly with PETSc. PETSc can be used to provide a “MPI parallel linear solver” in an otherwise sequential, or OpenMP parallel code. This approach cannot provide extremely large improvements in the application time by utilizing large numbers of MPI processes but can still improve the performance. Certainly all parts of a previously sequential code need not be parallelized but the matrix generation portion must be parallelized to expect true scalability to large numbers of MPI processes. See PCMPI for details on how to utilize the PETSc MPI linear solver server. Since PETSc is under continued development, small changes in usage and calling sequences of routines will occur. PETSc has been supported for twenty-five years; see mailing list information on our website for information on contacting support.

97 MATHEMATICS AND COMPUTING↗

Advancements of On-Line Monitoring and Real-Time Characterization of Actual Low-Level Hanford Tank-Waste Samples

Waste and process stream characterization is essential to the safe, efficient, and cost-effective processing of Hanford Site materials. The demand for materials characterization including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward Hanford waste treatment and immobilization. Our past work has applied Raman on-line monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105 and has demonstrated the quantitative measurement of nine analytes within this waste. To demonstrate broader applicability, this method has now been expanded to waste from two additional Hanford tanks, AW-102 and AP-107, and the offgas condensate from lab-scale melter runs of actual-tank waste feeds. To enhance the performance of the Raman method, instruments with various excitation wavelengths were compared, since it is known that the Raman response is enhanced by shorter wavelength excitation. The laser excitations for the three systems tested were 404 nm, 532 nm, and 671 nm. In addition to laser wavelength selection, the laser power, measurement integration times, and signal averaging techniques were also investigated to determine their effect on detection limits for oxy-anion analytes within tank wastes. These advancements in Raman capability are compared with past standards and will be presented.

Bryan, Samuel A.↗