Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vulnerabilities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Reverse Engineering of Medical Devices for Innovation and Advancement in Healthcare

• Medical technology is rapidly evolving and introducing new functionality and methodologies that suggest a higher risk for common vulnerability exposures (CVE) • Introduction of functionalities like Wi-Fi, Bluetooth, and internet connectivity require devices to be rigorously evaluated for vulnerabilities • Subsequently like many other fields cell-phone interconnectivity suggests a significantly higher level of risk to critical infrastructure and data security

Baldwin, David [Savannah River National Laboratory↗

Deploying Adversarial Attacks in Super-Resolution Models

Reliable super-resolution methods are crucial for applications like remote sensing, grid resilience and disaster impact analysis, and standoff biometrics. These methods infuse additional high-frequency information into reconstructions, allowing for better contextualization and image intelligence. However, super-resolution models can also introduce hallucinations or other unseen vulnerabilities that could be exploited by an adversary. This is further compounded by the prominence of deep learning in these models, as models are often blindly applied on out-of-distribution images. In this work, we implement adversarial attacks in common open-source super-resolution models and examine their impact on reconstructions and downstream classification tasks. We find that an adversarially trained super-resolution model can produce high-quality reconstructions that degrade downstream classifications. Moreover, these attacks do not require access to low-resolution imagery or class labels at inference time. These results demonstrate the vulnerability of super-resolution methods to malicious actors and motivates the development of a detector for super-resolution adversarial attacks. Further exploration of adversarial attacks in this domain is required to ensure trustworthiness and robustness of super-resolution models for national security applications.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Enhancing Power Resilience for Remote Communities: A Comprehensive Renewable Energy Solution for Itbayat Island

The island of Itbayat, Philippines, faces significant challenges in maintaining a reliable and resilient power supply due to its current reliance on a vulnerable power distribution system managed by a local electric cooperative. The existing infrastructure, which includes diesel generators and a radial network configuration with some above-ground lines, is highly susceptible to frequent typhoons and adverse weather conditions. These factors, combined with inadequate staffing and high operational costs, result in frequent power outages that disrupt daily life and hinder economic development. This white paper proposes a comprehensive solution to enhance the resilience and reliability of Itbayat's power system by integrating renewable energy sources, specifically solar photovoltaic (PV) systems, battery storage, and a microgrid controller. The proposed solution aims to reduce dependency on diesel fuel, optimize energy use, and provide a sustainable and robust power supply for the island. Key components of the solution include: 1. Solar PV Installation: Deploying solar PV panels to harness abundant solar energy, reducing reliance on diesel fuel. 2. Battery Storage Systems: Installing battery storage to store excess solar energy and ensure a continuous power supply during low solar generation periods. 3. Microgrid Controller: Implementing a microgrid controller to manage and optimize the integration of solar PV, battery storage, and existing diesel generators. The proposed solution addresses several critical issues, including system vulnerability, generator dependency, and operational inefficiencies. By adopting this innovative approach, Itbayat Island can achieve a more resilient, efficient, and sustainable energy infrastructure, ensuring a stable power supply for its residents and enhancing overall energy security.

14 SOLAR ENERGY↗

Strategic Energy Plan: City of Key West, Florida

This Strategic Energy Plan for the city of Key West, Florida—developed through the U.S. Department of Energy’s Energy Technology Innovation Partnership Project (ETIPP)—outlines a comprehensive strategy to advance the city’s energy vision: to improve energy efficiency and independence using local energy resources to foster long-term resilience. To guide this effort, the plan is structured around four focus areas: • Energy efficiency: Reduce overall energy consumption and utility costs across municipal, residential, and commercial buildings. • Local energy generation: Increase the share of energy produced from local sources to enhance energy independence. • Resilience: Strengthen critical infrastructure and community preparedness for flooding, hurricanes, and other natural weather hazards. • Electric transportation: Support the addition of new electric vehicles (EVs) and develop reliable charging infrastructure to reduce reliance on imported fuels. ETIPP provides strategic energy planning, technical assistance, and direct funding to U.S. coastal, remote, and island communities to improve energy resilience. Key West was part of ETIPP’s fourth cohort. As a low-lying island community vulnerable to infrastructure damage due to natural weather hazards, Key West seeks to reduce its dependence on external energy and build long-term sustainability. The Strategic Energy Plan identifies specific challenges, sets clear goals, and proposes actionable opportunities with implementation timelines and key stakeholders. A baseline assessment reveals significant energy consumption in both city-owned and residential/commercial buildings, limited local energy generation, and an early-stage EV market with vulnerable charging infrastructure. The proposed solutions emphasize a multifaceted approach, leveraging both established and innovative technologies, while addressing financial, technical, and community engagement challenges. The baseline assessment provided a snapshot of current energy conditions in Key West, evidencing key challenges and opportunities across the city’s energy priorities. Building on the baseline assessment and extensive input from city staff, local stakeholders, and community partners, a set of targeted opportunities was identified to address Key West’s energy goals. Each was evaluated in terms of its potential benefits, key implementation steps, associated challenges and mitigation strategies, and the city departments and stakeholders best positioned to lead or support progress.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

TASTI-GRID: a holistic view of Florida's grid resilience opportunities

In December of 2025, the American Society of Civil Engineers updated Florida’s infrastructure grade to a ”C+” – reflecting overall investments in recent years. With the recommendation to further strengthen the electric grid and establish consistent building standards, extreme weather, aging infrastructure, and population in-migration are still compounding Florida’s grid vulnerabilities. Key challenges related to hurricane and other tropical & marine weather events are not unique to Florida. However, the state’s topography, location, demographics, and variation among rural and urban centers for tourism and industry, demonstrate the need for unique approaches to advancing critical infrastructure resilience, particularly for large concentrations of elderly residents or in areas of historic underinvestment. Florida’s grid asset advancements are credited with a reduction in average power outage durations. Yet, improvements since 2021 have set the stage for future resilience activities – as modernization efforts have greatly improved data collection – enabling better understanding of vulnerabilities and trends across counties and localities (particularly in Central Florida).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Reactor Designs Security Analysis, Risk, and Recommendations: Risks, Consequences, and Possible by-Design Mitigation Approaches Associated with Select Advanced Reactors

Next-generation advanced reactors (ARs) incorporate enhanced safety systems, have smaller source terms, and feature compact modular designs, which should lessen their collective risk profiles. However, to fully evaluate risk, security needs to be a part of the equation. Without taking security into consideration, safety systems and components in the new ARs may be vulnerable to sabotage. These base attributes, coupled with enhanced security features specific to AR design through sound engineering and security-by-design (SeBD), should provide developers and operators with lower inherent security risk profiles. Building security early into the AR design may remove or passively secure potential critical targets from an adversary’s reach , thereby increasing overall safety and security. An integrated approach and diverse design team that includes engineering, operations, and security experts are fundamental to building security into the design without sacrificing fundamental operational efficiencies and principles. The objective of this project was to evaluate the security and safety interfaces for five classes of reactors, identify potential security vulnerabilities of structures, systems, and components (SSC), and underscore the need to consider security alongside safety in the design o f these concepts. The five reactor classes evaluated in this project and presented in this report are molten-salt reactors (MSR), high temperature gas reactors (HTGR), sodium-fast reactors (SFR), advanced light-water reactors (ALWR), and microreactors. These designs were selected because they reflect the concepts that are closest to market deployment and have received significant resource investments from the public and private sector. This project assesses the inherent security risks posed by common classes of ARs, provides a methodology and framework to assess security along with safety, and offers an analysis of potential mitigation strategies that could be incorporated. For each AR technology, the SSCs that relate to radionuclide source safety functions are discussed to understand the SSC contribution to safety and relative importance in the protective strategy for the design. The assumptions that went into evaluating each reactor concept originated from generic publicly available nonproprietary information and should not directly be used to qualify an absolute risk profile nor to rank specific AR designs. Instead, the purpose of the analysis is to understand and compare the generic inherent security risks of different AR technologies.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Securing the Modern Grid: Federal Investments, Digitization, and Supply Chain Strategy

Across the United States (U.S.) grid expansion and modernization is underway, paving the way for accelerated load growth and intelligent resource management. Digitization of the grid is supported by several state and federal programs, providing support for utilities installing advanced metering infrastructure (AMI), AI-powered analytics systems, battery energy storage systems (BESS), and distributed energy resource management systems (DERMS) to transform the grid from a one-way power delivery system into an intelligent, responsive network that will enable faster load growth and power expansion of data centers for advanced artificial intelligence (AI) applications. The digital transformation of America's grid presents opportunity for increased efficiency and resiliency but also introduces new digital risks that require careful management. Digital equipment often contains several vulnerabilities such as unencrypted communication protocols, and persistent remote access capabilities that could be exploited to manipulate device settings, coordinate service disruptions, or inject false data into grid operations. These digital risks become particularly important as the grid must rapidly scale to support AI-driven data centers, which the administration has identified as essential for maintaining U.S. technological leadership and economic competitiveness. These vulnerabilities are compounded by supply chain realities: Chinese manufacturers currently produce 70-90% of essential grid components including inverters, batteries, and control systems, with the U.S. lacking domestic manufacturing capacity for critical assets like extra-high voltage transformers. Recent federal legislation has established Foreign Entity of Concern (FEOC) restrictions to address these risks, requiring projects to achieve escalating thresholds of non-FEOC content to receive tax credits while utilities work to expand sourcing channels for their supply chains and strengthen security measures. These restrictions arrive precisely when utilities face unprecedented electricity demand growth driven by the rapid growth in data centers, creating a considerable challenge: rapidly expanding infrastructure while navigating complex compliance requirements while lacking viable alternatives for many critical components. Idaho National Laboratory (INL) and its partners have developed practical approaches to help utilities navigate these intersecting challenges as they leverage federal investment to strengthen and grow the grid. These solutions include Cyber-Informed Engineering (CIE) principles that build resilience directly into systems, the Cirrus tool for secure cloud migration, and enhanced procurement guidance that embeds security requirements throughout equipment lifecycles. Federal initiatives, such as the Technical Assistance for Digital Assurance (TADA) project, provide direct support to utilities implementing these approaches while facilitating knowledge sharing across the industry. While these tools and frameworks cannot eliminate all risks inherent in foreign supply chain dependencies, they offer pragmatic pathways for strengthening security posture without sacrificing the deployment momentum essential to meeting surging electricity demand. Ultimately, securing America's digital energy infrastructure demands dedicated coordination across multiple fronts: building domestic supply chains, implementing robust digital assurance practices, and maintaining the aggressive modernization timeline necessary for reliability, resilience, and energy independence.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Utilizing Time Reversal Ultrasonics to Detect the Removal of Nuclear Materials from Geological Repositories (FY26 Mid-Year)

Detecting unauthorized nuclear material removal from storage environments, such as geological repositories, is a critical safeguards task essential to ensuring the integrity and non-diversion of nuclear materials. However, this process is fraught with significant technical challenges. Storage configurations often involve tightly packed nuclear material containers or obstructed environments, making detection of removal events exceedingly difficult. Optical surveillance cameras, which are commonly used for monitoring, suffer from substantial limitations, including restricted coverage, reliance on line-of-sight measurements, and vulnerability to environmental conditions in certain storage scenarios. As the global inventory of monitored nuclear materials increases and storage configurations become more complex— such as deep geological repositories, inaccessible storage vaults, and tightly packed containers—there is an urgent need for innovative detection technologies that can reliably identify unauthorized diversion events in these challenging environments. The challenge of detecting nuclear material removal in complex storage environments is both significant and urgent. Preventing unauthorized access, diversion, or tampering with nuclear materials is a cornerstone of global nuclear safeguards and nonproliferation efforts. Current detection methods are increasingly inadequate as storage configurations become more intricate and inaccessible. The limitations of existing technologies—such as their inability to detect changes behind obstructions, reliance on costly and labor-intensive processes, and vulnerability to environmental conditions—pose risks to the effectiveness of safeguards systems. Addressing this challenge is critical to maintaining international trust in nuclear safeguards frameworks and ensuring compliance with nonproliferation agreements. Our project builds on the proven concept of TRU technology that can address this unmet need. TRU has demonstrated exceptional spatial sensitivity and change detection capabilities in complex non-line-ofsight environments, making it uniquely suited for detecting unauthorized nuclear material removal in challenging storage configurations. Unlike optical methods, TRU is not limited by line-of-sight constraints or environmental conditions, enabling reliable detection of subtle alterations even behind obstructions. By leveraging TRU’s ability to identify removal or tampering events, we aim to develop a robust detection system that enhances safeguards in geological repositories, storage vaults, and other complex environments.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Precursor Analysis Report: SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003

The SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003 Precursor Analysis Report leverages publicly available information about Davis-Besse’s 2003 cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 25 January 2003, the SQL Slammer worm infected more than 90% of vulnerable hosts and crashed the internet in 10 to 15 minutes, making it one of the fastest spreading worms in history. SQL Slammer is a fileless, memory-resident worm that remotely exploits a stack-based buffer overflow vulnerability on local hosts to intensively scan and rapidly self-propagate across the internet. The worm infected approximately 300,000 unpatched hosts running Microsoft Structured Query Language (SQL) Server 2000 or Microsoft Desktop Engine (MSDE) 2000 with SQL Server Resolution Service. The SQL Slammer worm indirectly infected FirstEnergy’s Davis-Besse nuclear power plant by first infecting a consultant’s company network server and then propagating through an external misconfigured connection into Davis-Besse’s site network. The infection caused major network congestion, slow performance, data overloads, and the inability of local hosts to communicate with each other, which eventually caused a loss of availability and a loss of view when the Safety Parameter Display System (SPDS) and Plant Process Computer (PPC) crashed. At the time of the infection, the plant was already offline, the digital monitoring systems had redundant analog backups, and the plant control and safety functions were not affected, so there were no concerns of a safety breach. However, this incident resulted in many lessons learned and spawned important discussions about cybersecurity’s role in nuclear safety and electric power reliability regulation, policy, and guidance. Researchers and analysts identified 10 unique techniques utilized during the attack with a total of 640 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Eight of the identified techniques used during Davis-Besse cyber attack were precursors to the triggering event. Analysis identified 596 observables associated with these precursor techniques, 428 of which were assessed to have an increased likelihood of being perceived in the 331 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Advanced Reactor Safeguards & Security Program: Cybersecurity Scenarios

The use of digital control systems and automation in advanced nuclear power systems introduces different types of vulnerabilities compared to legacy (i.e. analog) control systems that cyber adversaries can exploit. These vulnerabilities pose a challenge to reactor operators and cyber operations staff due to the dynamic nature of the event in which a human response or a lack of response can potentially evolve into a worsening plant condition. Using the Department of Homeland Security Cyber and Infrastructure Security Agency’s (CISA) critical infrastructure exercise framework, this document presents several cyber security scenarios typical of digital control systems that could be used in advanced reactor designs. These scenarios can be used in tabletop exercises to evaluate cyber security posture or conduct training on different aspects of cyber security, including detection, threat hunting using indicators of compromise, evaluating incident response, risk mitigation, incident reporting, information sharing and recovery.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Data Center Cybersecurity, Supply Chain Risk Management, and Emerging Regulation Cohort Summary: Takeaways and Action Plans

This report summarizes the outcomes of the Data Center Cohort under the Department of Energy’s Technical Assistance for Digital Assurance (TADA) initiative, aimed at enhancing grid resilience through cybersecurity, supply chain risk management (SCRM), and Cyber-Informed Engineering (CIE). The cohort engaged 17 organizations across utilities, data center operators, vendors, and technology providers in three sessions combining presentations, discussions, and exercises. Key topics included AI-driven load behavior, cybersecurity vulnerabilities in UPS/BESS and cooling systems, governance gaps at utility–data center boundaries, and supply chain integrity. Five cross-cutting themes emerged: interconnection architecture vulnerabilities, fragmented governance, AI-driven stability risks, lack of regulatory frameworks, and long-term supply chain concerns. Actionable recommendations were developed, including implementing DMZ segmentation, formalizing vendor access agreements, designing AI workload limits, and advancing standards through NERC and state-level programs. These strategies aim to strengthen resilience, clarify responsibilities, and ensure secure integration of data centers into the grid.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

FIC Consequence Profile - Hypothetical Cybercrime Syndicate Adversary Dossier

The FIC team has engaged PNNL’s Shamrock Cyber team to produce this Consequence Profile. This Consequence Profile is an Adversary Dossier, which provides the foundation for a thorough understanding of unacceptable mission outcomes, and the threats and vulnerabilities that make these outcomes plausible. The dossier helps stakeholders and development teams understand each other’s viewpoints. It also provides a means for reducing overall risk by prioritizing threats and vulnerabilities based on unacceptable outcomes. The Consequence Profile can be used as is, or as content to inform other reports tailored to a specific audience. It is intended to enable decision makers at all levels to improve the security posture of the system.

Beaman, Jacob E.↗

Evaluation of Hardware and Software Bill of Materials (HBOMs/SBOMs) Extraction Methods

Hardware and software bills of materials (HBOMs and SBOMs) provide important visibility into the components, dependencies, and supply chain relationships within programmable digital devices. This visibility is critical for advanced nuclear reactor applications, where use of common or shared hardware components, software libraries, suppliers, or manufacturing processes may create common cause failure (CCF) vulnerabilities despite apparent diversity. This paper evaluates current approaches for obtaining and analyzing HBOMs and SBOMs in support of CCF, diversity and defense-in-depth (D3) assessments, and begins to explore potential methods for artificial intelligence/machine learning-based analysis. The availability of BOM information from advanced reactor manufacturers and vendors, representative hardware and software categories found in advanced reactor systems continues to limit research [13]. This paper compares commonly used BOM formats, including CycloneDX, SPDX, and SWID. It also surveys publicly available tools for generating BOMs from source code, compiled binaries, and hardware-related information, noting limitations in language coverage, system age, and format interoperability. Finally, this paper evaluates methods for correlating BOM data with vulnerability and exploitability information, including VEX, CVE, and CWE resources. The findings indicate that publicly available nuclear-vendor BOMs are limited, making third-party extraction and research into novel analysis techniques necessary.

Cybersecurity↗

Tritium Transport at the Rulison Site, a Nuclear-stimulated Low-permeability Natural Gas Reservoir

The U.S. Department of Energy (DOE) and its predecessor agencies conducted a program in the 1960s and 1970s that evaluated technology for the nuclear stimulation of low-permeability natural gas reservoirs. The second project in the program, Project Rulison, was located in west-central Colorado. A 40-kiltoton nuclear device was detonated 2,568 m below the land surface in the Williams Fork Formation on September 10, 1969. The natural gas reservoirs in the Williams Fork Formation occur in low permeability, fractured sandstone lenses interbedded with shale. Radionuclides derived from residual fuel products, nuclear reactions, and activation products were generated as a result of the detonation. Most of the radionuclides are contained in a cooled, solidified melt glass phase created from vaporized and melted rock that re-condensed after the test. Of the mobile gas-phase radionuclides released, tritium ({sup 3}H or T) migration is of most concern. The other gas-phase radionuclides ({sup 85}Kr, {sup 14}C) were largely removed during production testing in 1969 and 1970 and are no longer present in appreciable amounts. Substantial tritium remained because it is part of the water molecule, which is present in both the gas and liquid (aqueous) phases. The objectives of this work are to calculate the nature and extent of tritium contamination in the subsurface from the Rulison test from the time of the test to present day (2007), and to evaluate tritium migration under natural-gas production conditions to a hypothetical gas production well in the most vulnerable location outside the DOE drilling restriction. The natural-gas production scenario involves a hypothetical production well located 258 m horizontally away from the detonation point, outside the edge of the current drilling exclusion area. The production interval in the hypothetical well is at the same elevation as the nuclear chimney created by the detonation, in order to evaluate the location most vulnerable to tritium migration.

02 PETROLEUM↗

Cyber Security Assessment Report: Adventium Labs

Major control system components often have life spans of 15-20 years. Many systems in our Nation's critical infrastructure were installed before the Internet became a reality and security was a concern. Consequently, control systems are generally insecure. Security is now being included in the development of new control system devices; however, legacy control systems remain vulnerable. Most efforts to secure control systems are aimed at protecting network borers, but if an intruder gets inside the network these systems are vulnerable to a cyber attack.

Source record↗

Evaluation Report on "The Department's Unclassified Cyber Security Program"

Industry experts report that security challenges and threats are continually evolving as malicious activity has become more web-based and attackers are able to rapidly adapt their attack methods. In addition, the number of data breaches continues to rise. In an effort to mitigate and address threats and protect valuable information, the Department of Energy anticipated spending about $275 million in Fiscal Year (FY) 2009 to implement cyber security measures necessary to protect its information technology resources. These systems and data are designed to support the Department's mission and business lines of energy security, nuclear security, scientific discovery and innovation, and environmental responsibility. The Federal Information Security Management Act of 2002 (FISMA) provides direction to agencies on the management and oversight of information security risks, including design and implementation of controls to protect Federal information and systems. As required by FISMA, the Office of Inspector General conducts an annual independent evaluation to determine whether the Department's unclassified cyber security program adequately protects its information systems and data. This memorandum and the attached report present the results of our evaluation for FY 2009. The Department continued to make incremental improvements in its unclassified cyber security program. Our evaluation disclosed that most sites had taken action to address weaknesses previously identified in our FY 2008 evaluation report. They improved certification and accreditation of systems; strengthened configuration management of networks and systems; performed independent assessments; and, developed and/or refined certain policies and procedures. In addition, the Department instituted a centralized incident response organization designed to eliminate duplicative efforts throughout the Department. As we have noted in previous reports, the Department continued to maintain strong network perimeter defenses against malicious intruders and other externals threats. These are positive accomplishments. However, in our judgment, additional action is required to further enhance the Department's unclassified cyber security program and help reduce risks to its systems and data. For example, our current review identified opportunities for improvements in areas such as security planning and testing, systems inventory, access controls, and configuration management. In particular, we issued a number of findings at sites managed by the National Nuclear Security Administration (NNSA). We also identified weaknesses across various Department program elements. Issues that warrant further attention include: (1) Weaknesses such as outdated security plans and not completing annual security control self-assessments were identified at several sites; (2) The Department had not yet resolved systems inventory issues and had yet to deploy a complex-wide automated asset management tool to help track information technology resources and identify interfaces between systems or networks; (3) Although certain improvements had been made to enhance access controls, we noted deficiencies such as a lack of periodic account reviews and inadequate password management at a number of sites; and (4) Previously identified weaknesses in configuration management had been corrected, however, we found problems related to weak administrator account settings and failure to install software patches, as well as incomplete implementation of the Federal Desktop Core Configuration. These internal control weaknesses existed, at least in part, because certain cyber security roles and responsibilities were not clearly delineated. Program officials also had not effectively performed monitoring and review activities essential for evaluating the adequacy of cyber security performance. In some cases, officials had not ensured that weaknesses discovered during audits and other evaluations were recorded and tracked to resolution in the organizations' Plans of Action and Milestones. Our testing disclosed that about 39 percent of existing corrective action milestones had missed estimated remediation dates, with many exceeding planned completion dates by at least one year. As a consequence, the risk of compromise to the Department's information and systems remained higher than necessary. To assist the continuing efforts to improve, we made several recommendations designed to help the Department's managers to strengthen the unclassified cyber security program and, thereby, protect its computer resources from unauthorized modification, loss, or disclosure of information. Due to security considerations, information on specific vulnerabilities and locations has been omitted from this report. Management officials at the sites evaluated were provided with detailed information regarding identified vulnerabilities, and, in many instances, initiated corrective actions.

99 GENERAL AND MISCELLANEOUS↗

COMPENDIUM: SURVEYS EVALUATING KNOWLEDGE AND OPINIONS CONCERNING HYDROGEN AND FUEL CELL TECHNOLOGIES

This compendium updates a 2003 literature review of surveys of knowledge and opinions of hydrogen and fuel cell technologies. Its purpose is to ensure that results of comparable surveys are considered in surveys conducted by the U.S. Department of Energy (DOE). Over twice as many studies related to the DOE survey have been published since 2003 than prior to that date. The fact that there have been significantly more studies implies that there have been further demonstration projects and/or increased interest in hydrogen and fuel cell technologies. The primary findings of these 15 new surveys, all of which were conducted in Europe (E) or North America (NA), to the DOE surveys are as follows: 1.Respondents who are more educated are more accepting of hydrogen technologies (NA). 2.Respondents who are more knowledgeable about hydrogen and/or fuel cells are more accepting of hydrogen technologies (E, NA). 3.When asked about issues of trust, respondents generally expressed distrust of the government or political parties but trusted scientists and environmental protection organizations (E). 4.Technical knowledge about hydrogen and fuel cell technologies is low (E, NA). 5.Respondents may express opinions about a technology even when they are lacking in knowledge of that technology (E). 6.Women and men have different priorities when deciding on an automobile purchase (E). 7.Public acceptance to hydrogen is vulnerable to perceptions of decreased safety (E, NA). 8.Public acceptance to hydrogen is vulnerable to perceptions of increased cost (E, NA). The DOE surveys are similar to surveys that examine technical knowledge of hydrogen and fuel cell technologies, although the technical questions are certainly different. The DOE surveys are also similar to the opinion surveys in that they address many of the same issues, such as safety, sources of energy information, or trust. There are many differences between the surveys reviewed in this compendium and the DOE surveys. The information for many of the surveys is collected face-to-face or electronically; however, all of the DOE surveys are conducted via telephone interviews. Most of the surveys concentrated on a specific population group, while the DOE surveys addressed five different populations (general public, students, government agencies, end users, and safety and codes officials). No survey (except the DOE survey) conducted since 2003 surveyed students knowledge and opinions of hydrogen and fuel cells. Although several surveys have solicited opinions of users (e.g., passengers of fuel-cell vehicles), no surveys were conducted of end users (industrial users needing large power supplies, commercial users needing uninterrupted power, or transportation businesses). While the International Organization for Standardization (ISO) has surveyed its membership concerning standards, the population of safety and codes officials has not been surveyed. The greatest impact and importance of the DOE surveys is that five distinct population groups are surveyed for both knowledge and opinions on hydrogen and fuel cells. Knowledge levels can be computed for each population group and can be compared across the populations and across time. Opinions can be compared with knowledge levels. A baseline of knowledge levels was derived using the results of the 2004 surveys; this baseline will be compared with the results of the knowledge evaluation for the surveys of 2008/2009 and 2011/2012. The DOE knowledge and opinion surveys are unique in coverage and purpose. It must be noted, however, that response rates for telephone surveys have decreased dramatically over time. Developments in survey methodology research will have to be followed over the next few years so that necessary adjustments are made in the 20112012 DOE hydrogen survey design, to account for cell-phone-only individuals as well as other changes in telephone usage demographics.

08 HYDROGEN↗

An Overview of Liquid Fluoride Salt Heat Transport Systems

Heat transport is central to all thermal-based forms of electricity generation. The ever increasing demand for higher thermal efficiency necessitates power generation cycles transitioning to progressively higher temperatures. Similarly, the desire to provide direct thermal coupling between heat sources and higher temperature chemical processes provides the underlying incentive to move toward higher temperature heat transfer loops. As the system temperature rises, the available materials and technology choices become progressively more limited. Superficially, fluoride salts at {approx}700 C resemble water at room temperature being optically transparent and having similar heat capacity, roughly three times the viscosity, and about twice the density. Fluoride salts are a leading candidate heat-transport material at high temperatures. Fluoride salts have been extensively used in specialized industrial processes for decades, yet they have not entered widespread deployment for general heat transport purposes. This report does not provide an exhaustive screening of potential heat transfer media and other high temperature liquids such as alkali metal carbonate eutectics or chloride salts may have economic or technological advantages. A particular advantage of fluoride salts is that the technology for their use is relatively mature as they were extensively studied during the 1940s-1970s as part of the U.S. Atomic Energy Commission's program to develop molten salt reactors (MSRs). However, the instrumentation, components, and practices for use of fluoride salts are not yet developed sufficiently for commercial implementation. This report provides an overview of the current understanding of the technologies involved in liquid salt heat transport (LSHT) along with providing references to the more detailed primary information resources. Much of the information presented here derives from the earlier MSR program. However, technology has evolved over the intervening years, and this report also describes more recently developed technologies such as dry gas seals. This report also provides a high-level, parametric evaluation of LSHT loop performance to allow general intercomparisons between heat-transport fluid options as well as provide an overview of the properties and requirements for a representative loop. A compilation of relevant thermophysical properties of useful fluoride salts is also included for salt heat transport systems. Fluoride salts can be highly corrosive depending on the container materials selected, the salt chemistry, and the operating procedures used. The report includes an overview of the state-of-the-art in reduction-oxidation chemistry control methodologies employed to minimize corrosion issues. Salt chemistry control technology, however, remains at too low a level of understanding for widespread industrial usage. Loop operational issues such as start-up procedures and system freeze-up vulnerability are also discussed. Liquid fluoride salts are a leading candidate heat transport medium for high-temperature applications. This report provides an overview of the current status of liquid salt heat transport technology. The report includes a high-level, parametric evaluation of liquid fluoride salt heat transport loop performance to allow intercomparisons between heat-transport fluid options as well as providing an overview of the properties and requirements for a representative loop. Much of the information presented here derives from the earlier molten salt reactor program and a significant advantage of fluoride salts, as high temperature heat transport media is their consequent relative technological maturity. The report also includes a compilation of relevant thermophysical properties of useful heat transport fluoride salts. Fluoride salts are both thermally stable and with proper chemistry control can be relatively chemically inert. Fluoride salts can, however, be highly corrosive depending on the container materials selected, the salt chemistry, and the operating procedures used. The report also provides an overview of the state-of-the-art in reduction-oxidation chemistry control methodologies employed to minimize salt corrosion as well as providing a general discussion of heat transfer loop operational issues such as start-up procedures and freeze-up vulnerability.

heat transfer↗