Search NASA⌕ Search

SEARCH · Search NASA

Results for “array detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Decay properties of long-lived isomers in the odd-odd N=81 nucleus {sup 146}Tb compared to the {sup 148}Ho and {sup 150}Tm nuclei

Excited states of the {sup 146}Tb nucleus have been studied using {gamma}-ray and electron spectroscopy in off-beam and in-beam modes following {sup 112}Sn({sup 40}Ar,3n3p) reaction with the use of the OSIRIS-II, HPGe detector array and the conversion electron spectrometer. The multipolarity of the 343 keV transition deexciting the (7{sup -}) level in {sup 146}Tb shows mainly an E2 nature and the first excited state above the 23 s isomer is assigned as a (5{sup -},6{sup -}) state. The log ft values have been deduced for 11 {beta}{sup +}/EC transitions populating excited states in {sup 146}Gd. The systematic behavior of spins and parities of the long-lived levels at 0+x keV and the first excited states above them in the N=81 isotones {sup 146}Tb, {sup 148}Ho, and {sup 150}Tm is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

BrachyView, a novel in-body imaging system for HDR prostate brachytherapy: Experimental evaluation

Purpose: This paper presents initial experimental results from a prototype of high dose rate (HDR) BrachyView, a novel in-body source tracking system for HDR brachytherapy based on a multipinhole tungsten collimator and a high resolution pixellated silicon detector array. The probe and its associated position estimation algorithms are validated and a comprehensive evaluation of the accuracy of its position estimation capabilities is presented. Methods: The HDR brachytherapy source is moved through a sequence of positions in a prostate phantom, for various displacements in x, y, and z. For each position, multiple image acquisitions are performed, and source positions are reconstructed. Error estimates in each dimension are calculated at each source position and combined to calculate overall positioning errors. Gafchromic film is used to validate the accuracy of source placement within the phantom. Results: More than 90% of evaluated source positions were estimated with an error of less than one millimeter, with the worst-case error being 1.3 mm. Experimental results were in close agreement with previously published Monte Carlo simulation results. Conclusions: The prototype of HDR BrachyView demonstrates a satisfactory level of accuracy in its source position estimation, and additional improvements are achievable with further refinement of HDR BrachyView’s image processing algorithms.

60 APPLIED LIFE SCIENCES↗

Search for light mediators in the low-energy data of the CONNIE reactor neutrino experiment

The CONNIE experiment is located at a distance of 30 m from the core of a commercial nuclear reactor, and has collected a 3.7 kg-day exposure using a CCD detector array sensitive to an~1 keV threshold for the study of coherent neutrino-nucleus elastic scattering. Here we demonstrate the potential of this low-energy neutrino experiment as a probe for physics Beyond the Standard Model, by using the recently published results to constrain two simplified extensions of the Standard Model with light mediators. We compare the new limits with those obtained for the same models using neutrinos from the Spallation Neutron Source. Our new constraints represent the best limits for these simplified models among the experiments searching for CE$ν$NS for a light vector mediator with mass $ {M}_{Z^{\prime }} $< 10 MeV, and for a light scalar mediator with mass M$_{\phi}$< 30 MeV. These results constitute the first use of the CONNIE data as a probe for physics Beyond the Standard Model.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

{gamma}-ray spectroscopy of {sub {lambda}}{sup 16}O and {sub {lambda}}{sup 15}N hypernuclei via the {sup 16}O(K{sup -},{pi}{sup -}{gamma}) reaction

The bound-state level structures of the {sub {lambda}}{sup 16}O and {sub {lambda}}{sup 15}N hypernuclei were studied by {gamma}-ray spectroscopy using a germanium detector array (Hyperball) via the {sup 16}O (K{sup -},{pi}{sup -}{gamma}) reaction. A level scheme for {sub {lambda}}{sup 16}O was determined from the observation of three {gamma}-ray transitions from the doublet of states (2{sup -},1{sup -}) at {approx}6.7 MeV to the ground-state doublet (1{sup -},0{sup -}). The {sub {lambda}}{sup 15}N hypernuclei were produced via proton emission from unbound states in {sub {lambda}}{sup 16}O. Three {gamma} rays were observed, and the lifetime of the 1/2{sup +};1 state in {sub {lambda}}{sup 15}N was measured by the Doppler shift attenuation method. By comparing the experimental results with shell-model calculations, the spin dependence of the {lambda}N interaction is discussed. In particular, the measured {sub {lambda}}{sup 16}O ground-state doublet spacing of 26.4{+-}1.6{+-}0.5 keV determines a small but nonzero strength of the {lambda}N tensor interaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pseudospin-doublet bands and Gallagher Moszkowski doublet bands in 100 Y

New transitions in neutron-rich 100 Y have been identified in a 9 Be + 238 U experiment with mass and Z gates to provide full fragment identification. These transitions and high spin levels of 100 Y have been investigated by analyzing the high statistics γ–γ–γ and γ–γ–γ–γ coincidence data from the spontaneous fission of 252 Cf at the Gammasphere detector array. Two new bands, 14 new levels, and 23 new transitions have been identified. The K π = 4 + new band decaying to a 1s isomeric state is assigned to be the high-K Gallagher-Moszkowski (GM) partner of the known K π = 1 + band, with the π5/2[522]Ⓧν3/2[411] configuration. This 4 + band is also proposed to be the pseudospin partner of the new K π = 5 + band with a 5 + π5/2[422] Ⓧ ν5/2[413] configuration, to form a π5/2[422] Ⓧ ν[3125/2,3/2] neutron pseudospin doublet. Here, constrained triaxial covariant density-functional theory and quantal particle rotor model calculations have been applied to interpret the band structure and available electromagnetic transition probabilities and are found to be in good agreement with experimental values.

100Y↗

Complementary studies of T=2 {sup 30}Al and the systematics of intruder states

Low-spin states were studied in {sup 30}Al following the {beta} decay of {sup 30}Mg produced in the fragmentation of 140-MeV/AMU {sup 48}Ca. Analysis of the {beta}-{gamma} and {beta}-{gamma}-{gamma} coincidences revealed a new 1{sup +} state at 2413 keV, confirmation of the level scheme, and a more accurate half-life measurement of 315(6) ms for the {sup 30}Mg ground state. Higher-spin states were investigated in the reaction of {sup 14}C on {sup 18}O at 22 MeV. Protons and deuterons were detected in a segmented E-{delta}E Si telescope in coincidence with one or two {gamma} rays in the FSU Ge detector array. A comparison of the resulting level and decay scheme with predictions of the sd shell model shows good agreement with all but six of the states in both excitation energy and {gamma}-decay branching ratios. The root-mean-square deviations in energy of these states using the older USD and newer USDA and USDB interactions were 265, 176, and 173 keV, respectively. The remaining six states are well described as 4{sup -} to 7{sup -} states, similar in relative energy to those in {sup 28}Al but shifted down by about 1200 keV. These states also agree well with the predictions of shell-model calculations using the WBP interaction. A comparison of the lowest 4{sup -} states in even A Na, Al, and P isotopes shows a systematic decrease in energy with increasing N and with decreasing Z. The energies of the 4{sup -} states are almost identical in nuclei with the same N-Z values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of the Ion Beam Focusing in a Mass Spectrometer using an IonCCD™ Detector

A position sensitive pixel-based detector array, referred to as the IonCCDTM, has been employed to characterize the ion optics and ion beam focusing in a custom built mass spectrometer designed for soft and reactive landing of mass-selected ions onto surfaces. The IonCCDTM was placed at several stages along the path of the ion beam to determine the focusing capabilities of the various ion optics which include an electrodynamic ion funnel, two radiofrequency (RF) only collision quadrupoles, a mass resolving quadrupole, a quadrupole bender, and two Einzel lens assemblies. The focusing capabilities of the RF-only collision quadrupoles and Einzel lenses are demonstrated by large decreases in the diameter of the ion beam. In contrast, the mass resolving quadrupole is shown to significantly defocus the mass-selected ion beam resulting in an expansion of the measured ion beam diameter. Combined with SIMION simulations we demonstrate that the IonCCDTM can identify minor errors in the alignment of charged-particle optics that result in erratic trajectories and significant deflections of the ion beam.. This information can be used to improve the design assembly and maintenance of custom-built mass spectrometry instrumentation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prompt and delayed spectroscopy of {sup 142}Tb using recoil-isomer tagging

Recoil-isomer tagging has been used to characterize the states built upon an I{sup {pi}}=8{sup +} isomer in {sup 142}Tb. High-spin states of the neutron-deficient nucleus {sup 142}Tb were populated using an {sup 54}Fe beam, accelerated onto a {sup 92}Mo target of thickness {approx}500 {mu}g/cm{sup 2} at energies of 245, 252, and 265 MeV using the K130 cyclotron at the University of Jyvaeskylae, Finland. Use of the JUROGAM target-position Ge-detector array coupled with the GREAT focal-plane spectrometer at the RITU gas-filled recoil separator has significantly increased the efficiency of the isomer-tagging technique. The rotational band built upon the I{sup {pi}}=8{sup +} isomeric state was established with isomer-tagged {gamma}-{gamma} coincidence data and angular distributions were measured for some of the more intensely populated states. Two previously unobserved bands that bypass the isomer were also established. The new data have been interpreted within the framework of the cranked-shell model. The data show good agreement with the calculated triaxial nuclear shape with {gamma}=-30 deg. for the {sup 142m2}Tb isomeric state. The B(M1)/B(E2) branching ratios, nuclear alignment, signature splitting, and reduced transition probability, B(E1), of the isomeric state have been systematically compared with those of the neighboring nuclei. These comparisons give further evidence for the {pi}h{sub 11/2} x {nu}h{sub 11/2} configuration of the isomer.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

OPTIMIZATION OF A TWO-STAGE ADR FOR THE SOFT X-RAY SPECTROMETER (SXS) INSTRUMENT ON THE ASTRO-H MISSION

NASA/Goddard Space Flight Center has begun developing the Soft X-ray Spectrometer (SXS) instrument that will be flown on the Japanese Astro-H mission. The SXS's 36-pixel detector array will be cooled to 50 mK using a two-stage adiabatic demagnetization refrigerator (ADR). A complicating factor for its design is that the ADR will be integrated into a superfluid helium dewar at 1.3 K that will be coupled to a 1.8 K Joule-Thomson (JT) stage through a heat switch. When liquid helium is present, the coupling will be weak, and the JT stage will act primarily as a shield to reduce parasitic heat loads. When the liquid is depleted, the heat switch will couple more strongly so that the ADR can continue to operate using the JT stage as its heat sink. A two-stage ADR is the most mass efficient option and it has the operational flexibility to work well with a stored cryogen and a cryocooler. The stages are operated independently, and this opens up a very large parameter space for optimizing the design. This paper discusses the optimization process and most relevant trades considered in the design of the SXS ADR, and its expected performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the U 235 ( n , f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy from 1 MeV to 20 MeV

The characterization of fission-driven nuclear systems primarily relies on calculations of neutron-induced chain reactions, and these calculations require evaluated nuclear data as input. Calculation accuracy heavily depends on input nuclear data evaluation accuracy, and thus high precision on the experimental input to the nuclear data evaluation is essential for fundamental quantities like the energy spectrum of neutrons emitted from neutron-induced fission (i.e., the prompt fission neutron spectrum, PFNS). Despite decades of measurement efforts, prior to the measurements described in this work there were only three literature data sets for the 235 U(n,f) PFNS at incident neutron energies above 1.0 MeV considered reliable for inclusion in nuclear data evaluations and no reliable data sets above 3.0 MeV incident neutron energy. In this work we report on new measurements of the 235 U(n,f) PFNS spanning a grid of 1.0–20.0 MeV in incident neutron energy and 0.01–10.0 MeV in outgoing (PFNS) neutron energy. These measurements were carried out at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center and used a multifoil parallel-plate avalanche counter target with both a Li-glass and a liquid scintillator detector array in separate experiments to span the quoted outgoing neutron energy ranges. The PFNS results are shown in terms of the energy spectra themselves as well as the average PFNS energy $(\langle{E}\rangle)$ and ratios of $\langle{E}\rangle$ at forward and backward angles. Here, the results are compared with literature data and selected nuclear data evaluations. Generally, the data agree with the ENDF/B-VIII.0 evaluation below 5.0-MeV incident neutron energy and more closely with the JEFF-3.3 evaluation above 5.0 MeV, though no evaluations considered for comparison in this work agree with the data across all of the incident and outgoing neutron energies shown, especially in regions where the third-chance fission process becomes available. Additionally, we show a ratio of the present PFNS results for 235 U(n, f) with a recent and highly correlated experiment to measure the 239 Pu(n, f) PFNS at the same experimental facility and with nearly identical equipment and analysis procedures. Many observations reported in this work are the first of their kind and represent significant advancements for knowledge of the 235 U(n, f) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Majorana Demonstrator: A Search for Neutrinoless Double-beta Decay of 76 Ge

Neutrinoless double-beta (0νββ) decay is a hypothesized process where in some even-even nuclei it might be possible for two neutrons to simultaneously decay into two protons and two electrons without emitting neutrinos. This is possible only if neutrinos are Majorana particles, i.e. fermions that are their own antiparticles. Neutrinos being Majorana particles would explicitly violate lepton number conservation, and might play a role in the matter-antimatter asymmetry in the universe. The observation of neutrinoless double-beta decay would also provide complementary information related to neutrino masses. The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, a 40-kg modular germanium detector array, to search for the 0νββ decay of 76Ge and to demonstrate a background rate at or below 3 counts/(ROI-t-y) in the 4 keV region of interest (ROI) around the 2039 keV Q-value for 76Ge 0νββ decay. In this paper, we discuss the physics of neutrinoless double beta decay and then focus on the MAJORANA DEMONSTRATOR, including its design and approach to achieve ultra-low backgrounds and the status of the experiment.

Xu, W.↗

A CUPID Li2100MoO4 scintillating bolometer tested in the CROSS underground facility

A scintillating bolometer based on a large cubic Li$_{2}$$^{100}$MoO$_4$ crystal (45 mm side) and a Ge wafer (scintillation detector) has been operated in the CROSS cryogenic facility at the Canfranc underground laboratory in Spain. The dual-readout detector is a prototype of the technology that will be used in the next-generation $0\nu2\beta$ experiment CUPID. The measurements were performed at 18 and 12 mK temperature in a pulse tube dilution refrigerator. This setup utilizes the same technology as the CUORE cryostat that will host CUPID and so represents an accurate estimation of the expected performance. The Li$_{2}$$^{100}$MoO$_4$ bolometer shows a high energy resolution of 6 keV FWHM at the 2615 keV $\gamma$ line. The detection of scintillation light for each event triggered by the Li$_{2}$$^{100}$MoO$_4$ bolometer allowed for a full separation ($\sim$8$\sigma$) between $\gamma$($\beta$) and $\alpha$ events above 2 MeV. The Li$_{2}$$^{100}$MoO$_4$ crystal also shows a high internal radiopurity with $^{228}$Th and $^{226}$Ra activities of less than 3 and 8 $\mu$Bq/kg, respectively. Taking also into account the advantage of a more compact and massive detector array, which can be made of cubic-shaped crystals (compared to the cylindrical ones), this test demonstrates the great potential of cubic Li$_{2}$$^{100}$MoO$_4$ scintillating bolometers for high-sensitivity searches for the $^{100}$Mo $0\nu2\beta$ decay in CROSS and CUPID projects.

47 OTHER INSTRUMENTATION↗

Skipper-CCD sensors for the Oscura experiment: requirements and preliminary tests

Oscura is a proposed multi-kg skipper-CCD experiment designed for a dark matter (DM) direct detection search that will reach unprecedented sensitivity to sub-GeV DM-electron interactions with its 10 kg detector array. Oscura is planning to operate at SNOLAB with 2070 m overburden, and aims to reach a background goal of less than one event in each electron bin in the 2–10 electron ionization-signal region for the full 30 kg-year exposure, with a radiation background rate of 0.01 dru.[1 dru (differential rate unit) corresponds to 1 event/kg/day/keV.] In order to achieve this goal, Oscura must address each potential source of background events, including instrumental backgrounds. In this work, we discuss the main instrumental background sources and the strategy to control them, establishing a set of constraints on the sensors' performance parameters. We present results from the tests of the first fabricated Oscura prototype sensors, evaluate their performance in the context of the established constraints and estimate the Oscura instrumental background based on these results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feeding of the 11/2{sup -} isomers in stable Ir and Au isotopes

Excited states in {sup 191}Ir, {sup 193}Ir, and {sup 197}Au were studied and absolute partial {gamma}-ray cross sections were measured using the (n,n{sup '}{gamma}) reaction. A Compton-suppressed germanium-detector array (GEANIE) for {gamma}-ray spectroscopy was used for the measurement and the broad-spectrum pulsed neutron source of the Los Alamos Neutron Science Center's WNR facility provided energetic neutrons. The energy of the incident neutrons was determined using the time-of-flight technique. Absolute partial {gamma}-ray cross sections were measured up to incident neutron energy of 20 MeV for several transitions feeding directly the 11/2{sup -} isomers and ground states in {sup 191}Ir, {sup 193}Ir, and {sup 197}Au. The feeding of the 11/2{sup -} isomers, which originate from the odd proton occupying the h{sub 11/2} orbital, was found for the three targets to be very similar and increasing relative to the feeding of the corresponding ground state with increasing neutron energy up to E{sub n}{approx}10 MeV. Above this neutron energy the opening of the (n,2n) reaction channel strongly affects the population of the isomers and leads to a decrease of their relative population compared to the population of the ground states. The experimental results are compared with theoretical predictions from the GNASH reaction model calculation implementing a version of the spin distribution for the pre-equilibrium reaction piece with either a compound nucleus spin distribution (CN-GNASH) or a Feshbach-Kerman-Koonin (FKK-GNASH) quantum mechanical spin distribution. The effects of the spin cutoff parameter values on the population of states are examined. Evidence is presented that FKK-GNASH provides a description of the experimental data that mitigates the need for adjustment of the level density parameter to fit the data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Persistence of chlorfluazuron in cabbage under different agro-climatic conditions of India and its risk assessment

Here, a multilocational field trial was conducted at 4 locations in India—Rajasthan, Gujarat, Madhya Pradesh, and West Bengal—to determine the persistence in cabbage of chlorfluazuron applied twice at 75 and 150 g active ingredient ha -1 . Cabbage head samples were collected from each replicated plot on 0 (2 h after spraying), 1, 3, 5, 7, 10, and 15 d after final insecticide application, including an untreated control. Chlorfluazuron residue in cabbage and field soil was estimated by high-performance liquid chromatography using a photo diode array detector. The limit of determination and limit of quantification of the method were recorded as 0.05 and 0.10 μg g -1 , respectively. Results revealed that chlorfluazuron dissipated linearly with progress of time, following first-order kinetics. The mean (± standard deviation) half-life value of chlorfluazuron in cabbage was found to be 7.18 ± 0.71 d, considering different locations and treatments. The residue was below the level of quantification in the harvested cabbage and soil samples. Harvesting cabbage in the experimental location, at least on day 7, after 2 applications of chlorfluazuron at the recommended dose, may not pose any ill effect for Indian adults.

59 BASIC BIOLOGICAL SCIENCES↗

The POLARBEAR Cosmic Microwave Background Polarization Experiment

The polarbear cosmic microwave background (CMB) polarization experiment has been observing since early 2012 from its 5,200 m site in the Atacama Desert in Northern Chile. polarbear's measurements will characterize the expected CMB polarization due to gravitational lensing by large scale structure, and search for the possible B-mode polarization signature of inflationary gravitational waves. polarbear's 250 mK focal plane detector array consists of 1,274 polarization-sensitive antenna-coupled bolometers, each with an associated lithographed band-defining filter and contacting dielectric lenslet, an architecture unique in current CMB experiments. The status of the polarbear instrument, its focal plane, and the analysis of its measurements are presented.

CMB polarization↗

Integrated SQUID/Sensor Metallic Magnetic Microcalorimeter for Gamma-Ray Spectroscopy

Metallic magnetic microcalorimeters (MMCs) achieve energy resolution comparable to transition-edge sensors (TESs) but rely on different measurement physics that may allow MMCs to surpass TESs in some future applications. We have recently completed fabrication of new MMC γ-ray detector arrays using several exploratory sensor designs. All designs integrate the SQUID and sensor on the same chip and use a superconducting cap layer on the paramagnet, but explore different combinations of combined/separate sensing and magnetization coils and direct/flux transformer coupling to the input SQUIDs. This report describes the design and initial testing of one of these devices, which has so far demonstrated an energy resolution of 38 eV at 60 keV near 10 mK using natural-abundance silver–erbium paramagnet.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗