Search NASA⌕ Search

SEARCH · Search NASA

Results for “beam driven”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Estimating Beam-Target Heating

At Los Alamos National Laboratory, two high-current linear induction accelerators (LIAs) are used to produce bremsstrahlung source spots for flash radiography of high-explosive driven hydrodynamic experiments at the Dual Axis Radiographic Hydrodynamic Test (DARHT) facility. Measurements of the electron-beam current density profile are valuable for understanding the beam dynamics in order to improve the quality of the radiography source spot. A technique commonly used at DARHT is to image the profile in Cerenkov or Optical Transition Radiation (OTR) light created by the beam striking a thin target inserted into the beam line. Target materials include aluminized dielectrics and titanium foils for OTR, and fused silica wafers for Cerenkov radiation. A practical complication with this technique is heating of the target by the electron beam. If the beam density is too great, the target can be destroyed. Moreover, even if the beam density is kept low enough to be nondestructive, the beam can heat the target to a high enough temperature to desorb gas from the surface. In that case, direct impact ionization of the gas by beam electrons can partially neutralize the beam, causing it to over-focus, thereby spoiling the data, if not destroying the target. The purpose of this note is to review some of the fundamental physics of electron beam heating in order to provide some elementary guidance for design of these imaging experiments to avoid overheating the target. Some specific examples for materials that we often use for imaging targets and beam-target experiments are provided.

43 PARTICLE ACCELERATORS↗

3D theory of microscopic instabilities driven by space-charge forces

Microscopic, or short-wavelength, instabilities are known for a drastic reduction of the beam quality and strong amplification of the noise in a beam. Space charge and coherent synchrotron radiation are known to be the leading causes of such instabilities. In this paper, we present a rigorous 3D theory of such instabilities driven by the space-charge forces. We define the condition when our theory is applicable to an arbitrary accelerator system with 3D coupling. Finally, we derive a linear integral equation describing such instability and identify conditions when it can be reduced to an ordinary second-order differential equation.

43 PARTICLE ACCELERATORS↗

Maintenance and operation procedure, and feedback controls of the J-PARC RF-driven H{sup −} ion source

In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second stage requirements of an H{sup −} ion beam of 60mA within normalized emittances of 1.5πmm•mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500μs×25Hz) and a life-time of longer than 1month, the J-PARC cesiated RF-driven H{sup −} ion source was developed by using an internal-antenna developed at the Spallation Neutron Source (SNS). The maintenance and operation procedure to minimize the plasma chamber (PCH) replacement time on the beam line, which is very important to maximize the J-PARC beam time especially for an antenna failure, is presented in this paper. The PCH preserved by filling argon (Ar) gas inside after pre-conditioning including pre-cesiation to produce the required beam at a test-stand successfully produced the required beam on the beam line with slight addition of cesium (Cs). The methods of the feedback controls of a 2MHz-RF-matching, an H{sup −} ion beam intensity and the addition of Cs are also presented. The RF-matching feedback by using two vacuum variable capacitors (VVCs) and RF-frequency shift produced the almost perfect matching with negligibly small reflected RF-power. The H{sup −} ion beam intensity was controlled within errors of ±0.1mA by the RF-power feedback. The amount of Cs was also controlled by remotely opening a Cs-valve to keep the RF-power lower than a settled value.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nanometer Structures for Fuel Cells and Displays, etc (Final Report)

Low-energy ion beam bombardment induced self-assembly has been used to form various periodic nano-size wave-ordered structures (WOS). Such WOS can be used as hard etching masks to produce nanowire arrays, trenches etc., on other materials by means of traditional etching or ion sputtering. These periodic nano-size structures have a wide range of applications, including flat panel displays, optical electronics, and clean energy technologies (solar and fuel cells, lithium batteries). In order to achieve high throughput of the above processes, a large area RF-driven multicusp nitrogen ion source has been developed for the application of nitrogen ion beam induced surface modification. An integrated ion beam system, which can house either a large area RF-driven multicusp ion source or a commercially available microwave ion source (Roth & Rau AG Tamiris 400-f) have been designed, manufactured, assembled, and tested.

30 DIRECT ENERGY CONVERSION↗

DEVELOPMENT OF THE SNS EXTERNAL ANTENNA H- ION SOURCE

The U.S. Spallation Neutron Source (SNS) is an accelerator-based, pulsed neutron-scattering facility currently in the process of ramping up neutron production. To meet present and future beam current and reliability requirements we are developing an RF-driven, H- ion source based on a ceramic aluminium nitride (AlN) plasma chamber surrounded by an external RF antenna. This report recounts the design of the prototype source, describes the Cs collar variations tested, enumerates recent modifications made to the source to prepare a production version, and summarizes the results of runs on the SNS test stand and Front End (FE) of the SNS accelerator. Up to ~100 mA unanalyzed beam currents (60Hz, 1ms) have been measured on the SNS ion source test stand, and up to 42mA have been successfully accelerated by the RFQ on the SNS front-end at lower RF power.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ion Beam Collimation For Improved Resolution In Associated Particle Imaging

Beam spot size on target for a Penning ion source has been measured under different source operating pressures as a function of the extraction channel length and beam energy. A beam halo/core structure was observed for ion extraction at low extraction voltages, and was greatly reduced at higher beam energy. Collimation through use of longer extraction channels results in reduced ion current on target; the resultant reduction in neutron yield for an API system driven by such an ion source can be compensated for by use of even higher beam energies.

43 PARTICLE ACCELERATORS↗

A Comparison Between Electronic Portal Imaging Device and Cone Beam CT in Radiotherapy Verification of Nasopharyngeal Carcinoma

The demand of greater accuracy in intensity-modulated radiotherapy (IMRT) has driven the development of more advanced verification systems. The purpose of this study is to investigate the differences in verification accuracy in terms of the position error detected between cone-beam computed tomography (CBCT) and electronic portal imaging device (EPID) in the IMRT of nasopharyngeal carcinoma (NPC). Two groups of NPC patients (n = 22 and n = 28) verified by CBCT (G1-CB), EPID (G1-EP), and EPID (G2-EP) only, respectively, were recruited. The positional errors between the G1-CB group and the G2-EP group were compared. In addition, the magnitudes of the position errors of EPID taken in the same session of the CBCT, but after necessary corrections (G1-EP), were analyzed. In the CBCT group, 455 CBCT images (G1-CB) and 206 EPID images (G1-EP) were collected, whereas 319 EPID images (G2-EP) for the EPID group, were recorded. The median position errors detected in CBCT were between 0.80 and 0.90 mm in the antero-posterior (A-P), left-right (L-R), and supero-inferior (S-I) directions, whereas those of the EPID were all 0.50 mm. The magnitude of position deviation detected by the CBCT was higher than that of the EPID and their differences were extremely significant (p < 0.001). The frequencies in the G2-EP group with position errors greater than the tolerance (2 mm) were 32, 42, and 27 in the A-P, L-R, and S-I directions, respectively, which accounted for 16.5%, 21.6%, and 13.9% of the total number of EPID. There was difference in verification capability between the CBCT and EPID when applied to IMRT of NPC patients. Because an average of 1 of 6 verifications in EPID was inferior to that of the CBCT, verification by CBCT is recommended.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Explainable Graph Learning for Particle Accelerator Operations

Particle accelerators are vital tools in physics, medicine, and industry, requiring precise tuning to ensure optimal beam performance. However, real-world deviations from idealized simulations make beam tuning a time-consuming and error-prone process. In this work, we propose an explanation-driven framework for providing actionable insight into beamline operations, with a focus on the injector beamline at the Continuous Electron Beam Accelerator Facility (CEBAF). We represent beamline configurations as heterogeneous graphs, where setting nodes represent elements that human operators can actively adjust during beam tuning, and reading nodes passively provide diagnostic feedback. To identify the most influential setting nodes responsible for differences between any two beamline configurations, our approach first predicts the resulting changes in reading nodes caused by variations in settings, and then learns importance scores that capture the joint influence of multiple setting nodes. Experimental results on real-world CEBAF injector data demonstrate the framework’s ability to generate interpretable insights that can assist human operators in beamline tuning and reduce operational overhead.

Wang, Song [Univ. of Virginia, Charlottesville, VA↗

The NO v A simulation chain

The NO v A experiment is a two-detector, long-baseline neutrino experiment operating in the recently upgraded NuMI muon neutrino beam. Simulating neutrino interactions and backgrounds requires many steps including: the simulation of the neutrino beam flux using FLUKA and the FLUGG interface, cosmic ray generation using CRY, neutrino interaction modeling using GENIE, and a simulation of the energy deposited in the detector using GEANT4. To shorten generation time, the modeling of detector-specific aspects, such as photon transport, detector and electronics noise, and readout electronics, employs custom, parameterized simulation applications. We will describe the NO v A simulation chain, and present details on the techniques used in modeling photon transport near the ends of cells, and in developing a novel data-driven noise simulation. Due to the high intensity of the NuMI beam, the Near Detector samples a high rate of muons originating in the surrounding rock. In addition, due to its location on the surface at Ash River, MN, the Far Detector collects a large rate ((˜) 140 kHz) of cosmic muons. Furthermore, we will discuss the methods used in NO v A for overlaying rock muons and cosmic ray muons with simulated neutrino interactions and show how realistically the final simulation reproduces the preliminary NO v A data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One-dimensional particle simulation of the filamentation instability: Electrostatic field driven by the magnetic pressure gradient force

Two counterpropagating cool and equally dense electron beams are modeled with particle-in-cell simulations. The electron beam filamentation instability is examined in one spatial dimension, which is an approximation for a quasiplanar filament boundary. It is confirmed that the force on the electrons imposed by the electrostatic field, which develops during the nonlinear stage of the instability, oscillates around a mean value that equals the magnetic pressure gradient force. The forces acting on the electrons due to the electrostatic and the magnetic field have a similar strength. The electrostatic field reduces the confining force close to the stable equilibrium of each filament and increases it farther away, limiting the peak density. The confining time-averaged total potential permits an overlap of current filaments with an opposite flow direction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oblique propagation and temperature effects on the resonant right-hand ion beam instability

The resonant right-hand instability (RHI) is often the dominant mode driven by reflected ions upstream of Earth’s quasi-parallel bow shock. In the tradition of Peter Gary, this paper further explores the right-hand instability using numerical solutions of the plasma dispersion relation and non-linear kinetic simulations, with parameters inspired by observations from NASA’s Magnetospheric Multiscale (MMS) mission. Agreement is found between the ion distributions in the particle-in-cell simulations and Magnetospheric Multiscale spacecraft data, which show the gyrophase bunching characteristic of the instability. The non-linear structures created by right-hand instability tend to be stronger when the plasma beta is lower. These structures have sizes of around 100 to 200 ion inertial lengths perpendicular to the magnetic field, presenting planet-sized disturbances to the magnetosphere. 2d and 3D hybrid particle-in-cell simulations show that modes with a range of propagation angles oblique to the magnetic field are excited, providing a ground to understand previous statistical studies of observed foreshock waves.

79 ASTRONOMY AND ASTROPHYSICS↗

Oblique Propagation and Temperature Effects on the Resonant Right-Hand Ion Beam Instability

The resonant right-hand instability (RHI) is often the dominant mode driven by reflected ions upstream of Earth’s quasi-parallel bow shock. In the tradition of Peter Gary, this paper further explores the right-hand instability using numerical solutions of the plasma dispersion relation and non-linear kinetic simulations, with parameters inspired by observations from NASA’s Magnetospheric Multiscale (MMS) mission. Agreement is found between the ion distributions in the particle-in-cell simulations and Magnetospheric Multiscale spacecraft data, which show the gyrophase bunching characteristic of the instability. The non-linear structures created by right-hand instability tend to be stronger when the plasma beta is lower. These structures have sizes of around 100 to 200 ion inertial lengths perpendicular to the magnetic field, presenting planet-sized disturbances to the magnetosphere. 2d and 3D hybrid particle-in-cell simulations show that modes with a range of propagation angles oblique to the magnetic field are excited, providing a ground to understand previous statistical studies of observed foreshock waves.

Ari Le↗

New methodology for measuring electron density perturbations caused by plasma coherent modes using profile reflectometry: Magnitudes and radial profiles in DIII-D

New capabilities of fast-sweep frequency-modulated profile reflectometry are explored to measure electron density ne perturbation magnitudes and radial profiles due to plasma coherent modes in DIII-D. The first approach is based on the frequency analysis of phase perturbations associated with high frequency (~MHz) Alfvén eigenmodes (AEs). The measurement of ~5.5 MHz fast-ion-driven global Alfvén eigenmodes (GAEs) is demonstrated in a neutral beam-heated DIII-D plasma. The GAE induced a broad radial distribution of phase perturbations in the profile reflectometer data. Analysis of these data determined the effective cutoff location displacement and the estimated ne fluctuation profile. In the second approach, high resolution ne profiles are used directly to determine the radial structure of ne perturbations due to a neo-classical tearing mode. These new measurements broaden the application of profile reflectometry and advance the development of AE spectroscopy as a tool for non-invasive diagnosis of fast-ion-driven modes in DIII-D and burning plasmas such as ITER.

47 OTHER INSTRUMENTATION↗

Emittance measurements for optimum operation of the J-PARC RF-driven H{sup −} ion source

In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second stage requirements of an H{sup −} ion beam of 60mA within normalized emittances of 1.5πmm•mrad both horizontally and vertically, a flat top beam duty factor of 1.25% (500μs×25Hz) and a life-time of longer than 1month, the J-PARC cesiated RF-driven H{sup −} ion source was developed by using an internal-antenna developed at the Spallation Neutron Source (SNS). The transverse emittances of the source were measured with various conditions to find out the optimum operation conditions minimizing the horizontal and vertical rms normalized emittances. The transverse emittances were most effectively reduced by operating the source with the plasma electrode temperature lower than 70°C. The optimum value of the cesium (Cs) density around the beam hole of the plasma electrode seems to be proportional to the plasma electrode temperature. The fine control of the Cs density is indispensable, since the emittances seem to increase proportionally to the excessiveness of the Cs density. Furthermore, the source should be operated with the Cs density beyond a threshold value, since the plasma meniscus shape and the ellipse parameters of the transverse emittances seem to be changed step-function-likely on the threshold Cs value.

43 PARTICLE ACCELERATORS↗

First-ever deployment of a SiPM-on-tile calorimeter in a collider: a parasitic test with 200 GeV p p collisions at RHIC.

We describe the testing of a prototype SiPM-on-tile iron-scintillator calorimeter at the Relativistic Heavy Ion Collider (RHIC) during its 200 GeV p p run in 2024. The prototype, measuring 20 × 20 cm 2 and 24 radiation lengths in depth, was positioned in the STAR experimental hall, approximately 8 m from the interaction point and 65 cm from the beam line, covering a pseudorapidity range of about 3.1 < η < 3.4. By using the dark current of a reference SiPM as a radiation monitor, we estimate that the prototype was exposed to a fluence of about 10 10 1-MeV n eq /cm 2 . Channel-by-channel calibration was performed in a data-driven way with the signature from minimum-ionizing particles during beam-on conditions. AGeant4 detector simulation, with inputs from thePythia8 event generator, describes measurements of energy spectra and hit multiplicities reasonably well. These results mark the first deployment, commissioning, calibration, and long-term operation of a SiPM-on-tile calorimeter in a collider environment. This experimental campaign will guide detector designs and operational strategies for the ePIC detector at the future EIC, as well as other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Breathing oscillations in enlarged cylindrical-anode-layer Hall plasma accelerator

Breathing oscillations in the discharge of an enlarged cylindrical-anode-layer Hall plasma accelerator are investigated by three-dimensional particle-in-cell (PIC) simulation. Different from the traditional breathing mode in a circular Hall plasma accelerator, the bulk plasma oscillation here is trigged by the potential barrier generated by the concentrated ion beam and substantial enough to compete with the anode voltage. The electric field near the anode is suppressed by the potential barrier thereby decreasing the electron density by {approx}36%. The discharge is restored to the normal level after the concentrated beam explodes and then it completes one cycle of electro-driven breathing oscillation. The breathing mode identified by the PIC simulation has a frequency range of {approx}156 kHz-{approx}250 kHz and does not vary monotonically with the discharge voltage.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reliability test of an electron cyclotron resonance ion source for accelerator driven sub-critical system

The reliability test of an electron cyclotron resonance ion source developed for accelerator driven sub-critical system is carried out in China Institute of Atomic Energy. A unique technique to improve the reliability is adopted. The source is operated for more than 200 h at 75 keV, 100 mA extracted hydrogen current, while 2 beam trips are recorded in the period, and uninterrupted operation time is about 150 h. The experimental result is described.

43 PARTICLE ACCELERATORS↗

Active beam position stabilization of pulsed lasers for long-distance ion profile diagnostics at the Spallation Neutron Source (SNS)

A high peak-power Q-switched laser has been used to monitor the ion beam profiles in the superconducting linac at the Spallation Neutron Source (SNS). The laser beam suffers from position drift due to movement, vibration, or thermal effects on the optical components in the 250-meter long laser beam transport line. We have designed, bench-tested, and implemented a beam position stabilization system by using an Ethernet CMOS camera, computer image processing and analysis, and a piezo-driven mirror platform. The system can respond at frequencies up to 30 Hz with a high position detection accuracy. With the beam stabilization system, we have achieved a laser beam pointing stability within a range of 2 rad (horizontal) to 4 rad (vertical), corresponding to beam drifts of only 0.5 mm 1 mm at the furthest measurement station located 250 meters away from the light source.

43 PARTICLE ACCELERATORS↗