Search NASA⌕ Search

SEARCH · Search NASA

Results for “code verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

IEEE STD. 1012 and NEI 96-07, Appendix D - Strange bedfellows? - 149

The final draft of a revision to IEEE Std. 1012-2012, 'IEEE Standard for System, Software and Hardware Verification and Validation', is expected to be approved for publication in June 2017. A draft of NEI 96-07, Appendix D, 'Supplemental Guidance for Application of 10 CFR 50.59 to Digital Modifications', has been submitted to the NRC staff for review and endorsement. What, if any, relationship exists between these two documents? How can the nuclear industry utilize the first one to help ensure success when applying the second one? NRC Regulatory Guides only endorse digital system and software related industry standards for application to safety-related systems and components, but the vast majority of digital modifications are made to non-safety related systems and components, so are these industry standards of little or no use when performing digital upgrades to non-safety related equipment? This paper answers these and other related questions and shows how application of a graded approach to verification and validation, utilizing the IEEE Std. 1012 concept of 'integrity level', can increase the likelihood of a 10 CFR 50.59 evaluation outcome that does not require prior NRC review and approval for non-safety related digital modifications. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An Open-Source Python Package for CFD Solution Verification

Informed decision-making using computational fluid dynamics (CFD) results requires quantifying the errors and uncertainties of a simulation. Verification, validation, and uncertainty quantification (VVUQ) methods were developed to address this need and have matured. However, these VVUQ analyses are often non-trivial and require CFD analysts and practitioners to have specific skill sets. This has led to the uneven adoption of VVUQ analyses, in part, based on the availability of software tools to aid CFD analysts and practitioners. Solution verification, a procedure to evaluate the accuracy of a simulation by estimating potential errors arising from the computational model and computing the uncertainties without comparing to results from a physical system, is one of the lagging VVUQ analyses as the absence of software has forced CFD analysts and practitioners to develop their own codes or piece together incomplete software from across the internet. This work presents an opensource Python package, CFDverify, to lower the barrier of entry and fill in the technological gap in solution verification. CFDverify also provides a streamlined framework to remove some potential errors in post-processing CFD results. The hope is that CFDverify can improve the quality and quantity of CFD solution verification in scientific and research studies and attract interest in developing a communal tool. This paper describes the design, features, and an example use of CFDverify.

Weinmeister, Justin [ORNL] (ORCID:0000000160090237↗

Divertor heat load estimates on NSTX and DIII-D using new and open-source 2D inversion analysis code

A thermography inversion algorithm has been developed in the open-source Python-based computer code, HYPERION, to calculate the heat flux incident on plasma-facing components (PFCs) in axisymmetric tokamaks. The chosen mesh size at the surface significantly affects the calculated transient heat flux results. The calculated transient heat flux will exceed the real value when the mesh size tends to zero but will underestimate the real value when the mesh size is large. A criterion for determining the appropriate mesh size for the transient heat flux calculation will be discussed. The numerical scheme for HYPERION uses a 2D fully implicit finite-difference approach, allowing temperature-dependent thermal properties of PFC materials. The inversion algorithm is benchmarked against established heat flux calculation codes, TACO and THEODOR, based on thermography data from NSTX and DIII-D respectively. The primary benefits of HYPERION compared to TACO and THEODOR are that it is open-source and it allows for the optimization of mesh thickness along the substrate. The algorithm also accounts for the thermal properties of thin surface layers that characteristically form on PFCs due to plasma-material interactions. The agreement between HYPERION and THEODOR is excellent, as the percent difference between the codes is ~5% on average in the case of the DIII-D data for moderate to high heat flux. Verification tests with TACO show slightly higher average percent differences of 8% and 12%. In using HYPERION to study filaments in heat flux, the initial results indicate that small ELMs filaments significantly broaden the divertor heat flux, and decrease divertor peak flux. Compared to the inter-ELM, the small ELM filaments decrease the divertor peak surface temperature. With intermittent divertor filaments, the divertor heat flux width is comparable with that found in L-mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application Results on Early Exascale Hardware

This Exascale Computing Project (ECP) milestone report summarizes the status of 27 of the 31 ECP Applications Development (AD) subprojects at the end of FY21. In November and December of 2021, a comprehensive assessment of AD projects was conducted by the ECP leadership along with external subject matter experts (SMEs). (NNSA application projects are reviewed separately using the ASC milestone process.) The AD review committee—consisting of the AD lead, AD deputy, Level 3 (L3), and at least one external project SME—was tasked with evaluating each project’s progress relative to ECP project goals specified in the FY21 timeline. Key areas of focus were code maturity and performance on pre-exascale systems, an in-depth analysis of final key performance parameter (KPP) verification contracts, and future R&D priorities in the final year of ECP and beyond. As such, this report contains not only an accurate snapshot of each subproject’s current status but also represents a broad account of successes and challenges in porting large scientific applications to DOE’s next-generation high-performance computing architectures – the Frontier and Aurora systems.

97 MATHEMATICS AND COMPUTING↗

Requirements Description of GAMSOR and GAMSRC

This report presents the modeling and simulation capabilities of Argonne National Laboratory’s GAMSOR and GAMSRC code that is used in present reactor analysis activities. These capabilities will then be used to establish the set of verification tasks necessary to verify GAMSOR for use on commercial projects. A similar approach was taken for the PERSENT, REBUS and DIF3D software packages. The GAMSOR program is a modified version of DIF3D used to obtain the coupled neutron gamma flux distributions for a given reactor system. GAMSOR was first developed in the 1980s and its work has progressed in parallel with DIF3D throughout its various development phases. While GAMSOR is compatible with DIF3D-FD and DIF3D-Nodal, DIF3D-VARIANT is most commonly used today and will be the focus of the present verification effort. As covered in [1], GAMSOR was built to provide more accurate heating distributions by explicitly solving for both the gamma and neutron heating distributions. Without this consideration, gamma heat is normally assumed to be deposited locally at the site of gamma production. This is acceptable for modeling some phenomena because the total energy production is preserved, but it can lead to inaccurate approximations of fluence-dependent behaviors such as fuel performance, swelling, cladding embrittlement, radiation induced creep, and power peaking. The outputs from GAMSOR are contained in multiple intermediate and final output files: FIXSRC, VARSRC, GTFLUX, GHFLUX, PWDINT, NPDINT, and GPDINT. DIF3D normally produces a PWDINT file containing power density results, with the assumption that gamma rays are absorbed where they are emitted (i.e., energy deposition is local with no modeled transport). With GAMSOR, neutron power density (NPDINT) and gamma power density (GPDINT) are both produced, with their summed power densities replacing the results in PWDINT for total heating (i.e., recoverable) power density.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Cylinder Occupancy and Measurement Suite

This software automatically records data from the Unattended Cylinder Verification Station, determines the state of the instrument, captures images of uranium hexafluoride shipment cylinders, and determines their weight. The code has been developed primarily for the International Atomic Energy Agency, but this type of instrument could be of interest to any facility operator in the uranium supply chain that handles uranium hexafluoride shipment cylinders (e.g. the 30B and 48Y cylinder). Operators may be interested in having this instrument confirm shipper declared measurement values upon receipt of a cylinder. They may also use it to aid in process monitoring if the quantity of material in the cylinder changes due to a processing activity.

Stewart, Scott L↗

[Presentation Slides] Code-to-Code Benchmark Study for Thermal Stress Modeling and Preliminary Analysis of the High-temperature Single Heat-Pipe Experiment

In the heat-pipe-cooled microreactor, heat pipes remove heat from the reactor core as a passive heat-transfer device, so the fluid circulation is not required for cooling, which can substantially simplify the overall reactor design. However, given the extremely high temperatures in the core region and potentially large temperature gradients across the structure materials, thermal stresses need to be well-analyzed to ensure structural integrity during normal operations and accident scenarios. This presentation slides discuss finite element method-based thermal-stress analysis for the high-temperature single heat-pipe test article in the Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL), using two commercial software packages, Abaqus and Star-CCM+. A code-to-code benchmark study was performed to crosscheck the model setup and capability of each code and to gain preliminary insights into the potential thermal stress concerns from the current experimental setup. It is observed the significant thermal stresses happen at the inner surface of the heat pipe hole surrounded by electric heaters where the largest temperature gradients appear. The temperature fields have good agreements between Abaqus and Star-CCM+, while the induced thermal stresses show modest deviations probably due to differences of meshing engines used in these two codes. It is found that the local maximum thermal stresses may reach close to the ultimate tensile strength and yield strength of structural material depending on the heater power. Ultimately, the coupled thermal-structural analysis will help guide the current experimental plan and ensure the facility safety for future experimental study.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Verification and Validation of the ENDF/B-VII.1 v4.3m1 MPACT 51-Group Cross Section Library

The MPACT neutronics module of the Consortium for Advanced Simulation of Light Water Reactors (CASL) core simulator is a 3-D whole core transport code being developed for the Virtual Environment for Reactor Analysis (VERA) CASL toolset. Key characteristics of the MPACT code include (1) a subgroup method for resonance selfshielding and (2) a whole-core transport solver with a 2-D/1-D synthesis method. The MPACT code requires a cross section library to support all of its core simulation capabilities; a cross section library would be MPACT’s most influencing component for simulation accuracy. Due to the limitation of computing capacity even in high performance computing, the cross section library must be developed to enhance computational efficiency in memory and computing time without losing accuracy and generality. This requires a very coarse energy group structure with about 50 groups. Multigroup (MG) neutron cross section libraries for the CASL VERA-CS neutronics simulator MPACT have been created by using the AMPX/SCALE code package developed at Oak Ridge National Laboratory (ORNL). A new 51-group structure was developed for efficient simulation to be applicable for both pressurized water reactor (PWR) and boiling water reactor (BWR) simulations. New v4.3m1 MPACT 51-group library with the ENDF/B- VII.1 nuclear data were developed for MPACT. Since SCALE KENO has some issues in the probability table and has a low cutoff energy for the free gas model, this issue has been corrected. This study focused on the development of the ENDF/B-VII.1 v4.3m1 MPACT MG library, including verification and validation. This document includes the library generation methodology and procedure, the verification procedure, and benchmark results compared to continuous energy Monte Carlo results using newly developed cross section libraries.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Source strength verification and quality assurance of preloaded brachytherapy needles using a CMOS flat panel detector

Purpose: Current methods of low dose rate brachytherapy source strength verification for sources preloaded into needles consist of either assaying a small number of seeds from a separate sample belonging to the same lot used to load the needles or performing batch assays of a subset of the preloaded seed trains. Both of these methods are cumbersome and have the limitations inherent to sampling. The purpose of this work was to investigate an alternative approach that uses an image-based, autoradiographic system capable of the rapid and complete assay of all sources without compromising sterility. Methods: The system consists of a flat panel image detector, an autoclavable needle holder, and software to analyze the detected signals. The needle holder was designed to maintain a fixed vertical spacing between the needles and the image detector, and to collimate the emissions from each seed. It also provides a sterile barrier between the needles and the imager. The image detector has a sufficiently large image capture area to allow several needles to be analyzed simultaneously.Several tests were performed to assess the accuracy and reproducibility of source strengths obtained using this system. Three different seed models (Oncura 6711 and 9011 {sup 125}I seeds, and IsoAid Advantage {sup 103}Pd seeds) were used in the evaluations. Seeds were loaded into trains with at least 1 cm spacing. Results: Using our system, it was possible to obtain linear calibration curves with coverage factor k = 1 prediction intervals of less than ±2% near the centre of their range for the three source models. The uncertainty budget calculated from a combination of type A and type B estimates of potential sources of error was somewhat larger, yielding (k = 1) combined uncertainties for individual seed readings of 6.2% for {sup 125}I 6711 seeds, 4.7% for {sup 125}I 9011 seeds, and 11.0% for Advantage {sup 103}Pd seeds. Conclusions: This study showed that a flat panel detector dosimetry system is a viable option for source strength verification in preloaded needles, as it is capable of measuring all of the sources intended for implantation. Such a system has the potential to directly and efficiently estimate individual source strengths, the overall mean source strength, and the positions within the seed-spacer train.

60 APPLIED LIFE SCIENCES↗

Microbial Taxonomy Run Amok

DNA sequencing has led to an explosion in discovery of microbial phylogenetic novelty, especially that represented by uncultivated taxa, to which the traditional system of prokaryotic taxonomy has not adapted. A lack of expansion of the International Code of Nomenclature of Prokaryotes (ICNP, 'the Code') to effectively capture this information has created a 'wild west' situation where names are published or appear in popular reference databases without further verification or validation. The rapid propagation of variant and questionable naming methods has led to widespread confusion and undermines prior accomplishments. Furthermore, we exemplify inconsistencies that have arisen from this practice and endanger the interoperability of scientific findings. The immediate solution to this problem is to develop and adopt universal best practices that are accepted by expert researchers, major publishers, the International Committee on Systematics of Prokaryotes (ICSP), and international microbiological societies.

59 BASIC BIOLOGICAL SCIENCES↗

Aeroelastic Modeling for Distributed Wind Turbines: March 11, 2021 - November 10, 2021

Aeroelastic modeling (AM) is the primary methodology for structural and performance assessment of any wind turbine whereby providing an understanding of the impact of design parameters on its loading and power response before witnessing it in the field. Despite these advantages, the use of AM in the Distributed Wind Technology (DWT) sector is limited, especially within the less established manufacturers. This project represents an in-depth assessment of the status of AM and its role within the Standards for the DWT industry. The study gathered input and feedback from a large number of national and international stakeholders, reviewed technical strengths and weaknesses of the current edition of the design standards, analyzed recent industry workshops' and meetings' minutes, collected publicly available AM templates, and provided an evaluation of the existing AM codes. The study achieved several goals including providing strategies for the load assessment categorization of turbines based on rotor swept area and archetype, and guidance for AM verification and validation (V&V), which includes discussions of measurement requirements and a sample test-plan useful for future V&V campaigns and design standard development. This document summarizes the different tasks conducted in the course of the project and highlights the steps required to improve the AM adoption based on a multifaceted approach that encompasses: 1) augmenting AM software capabilities, 2) publishing AM best-practices and design-basis, 3) creating new model templates, 4) providing guidance for V&V of codes and specific turbine models leveraging field testing best-practice, and 5) addressing weaknesses in the current standards. Many of the future objectives identified in this study could leverage NREL's upcoming testing campaigns of three modern distributed wind turbines. Recommendations within this study will advance the value and the ease-of-use of AM, thereby allowing the industry to better capitalize this underutilized tool resulting in a more efficient design process, an easier path to certification, and overall better and more distributed reliable wind turbine products.

17 WIND ENERGY↗

Intrafraction Verification of Gated RapidArc by Using Beam-Level Kilovoltage X-Ray Images

Purpose: To verify the geometric accuracy of gated RapidArc treatment using kV images acquired during dose delivery. Methods and Materials: Twenty patients were treated using the gated RapidArc technique with a Varian TrueBeam STx linear accelerator. One to 7 metallic fiducial markers were implanted inside or near the tumor target before treatment simulation. For patient setup and treatment verification purposes, the internal target volume (ITV) was created, corresponding to each implanted marker. The gating signal was generated from the Real-time Position Management (RPM) system. At the beginning of each fraction, individualized respiratory gating amplitude thresholds were set based on fluoroscopic image guidance. During the treatment, we acquired kV images immediately before MV beam-on at every breathing cycle, using the on-board imaging system. After the treatment, all implanted markers were detected, and their 3-dimensional (3D) positions in the patient were estimated using software developed in-house. The distance from the marker to the corresponding ITV was calculated for each patient by averaging over all markers and all fractions. Results: The average 3D distance between the markers and their ITVs was 0.8 {+-} 0.5 mm (range, 0-1.7 mm) and was 2.1 {+-} 1.2 mm at the 95th percentile (range, 0-3.8 mm). On average, a left-right margin of 0.6 mm, an anterior-posterior margin of 0.8 mm, and a superior-inferior margin of 1.5 mm is required to account for 95% of the intrafraction uncertainty in RPM-based RapidArc gating. Conclusion: To our knowledge, this is the first clinical report of intrafraction verification of respiration-gated RapidArc treatment in stereotactic ablative radiation therapy. For some patients, the markers deviated significantly from the ITV by more than 2 mm at the beginning of the MV beam-on. This emphasizes the need for gating techniques with beam-on/-off controlled directly by the actual position of the tumor target instead of external surrogates such as RPM.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single-Bubble Flow Boiling Phenomena - Interface Tracking Simulation

Boiling, as one of the most efficient heat transfer mechanisms, is widely used in various engineering systems. Better understanding and modeling of this process remains a major challenge in multiphase flow research. The distribution of vapor in boiling system affects the heat transfer rate and may cause unfavorable conditions, such as heater burn-out. A number of flow regimes have been observed experimentally. In general, there are three regimes under boiling conditions: nucleate boiling, transition boiling, and film boiling. The nucleate boiling regime is categorized into partial boiling regime and fully developed nucleate boiling, according to behavior of bubble dynamics and heat transfer characteristics. In the first region, as the wall temperature increases, the fraction of the wall surface subject to nucleate boiling increases until bubble formation occupies the entire heated surface. Heat transfer in this region is a complex mixture of single-phase forced convection and nucleate boiling. As bubble density increases, bubbles turn to coalesce and form insulating vapor patches, which impedes liquid flow back to the surface. The heat transfer rate under this condition reduces dramatically. This point is called Critical Heat Flux (CHF), which leads to boiling crisis. The behavior of boiling crisis is dependent on local fluid conditions due to bubble growth and departure. Experiments are the ultimate tool for boiling model development and verification, but they still lack some capabilities needed for better understanding of the local mechanism of this phenomena. It's difficult to capture many important details at the pressure/temperature conditions of interest using experimental techniques, such as full three dimensional measurements of velocity and temperature distribution and estimates of heat flux partitioning during the boiling process. The interface tracking simulation (ITS) is one of the promising approaches to describe heat transfer of boiling phenomena and their underlying mechanisms. The advances of high performance computing (HPC) in recent years made it possible to apply DNS to a wide variety of adiabatic flows. Some work has been done to implement evaporation / condensation models as well. Lee and Nydahl performed a numerical simulation of bubble growth and departure assuming that the bubble has the shape of a truncated sphere and a micro-layer exists during bubble growth. A 2-D cylindrical bubbles simulation has been done by Son with a simplified model to predict the heat flux in a thin liquid micro-layer. A direct simulation of 2D film boiling is conducted by Juric and Tryggvason. The film boiling, below critical pressure with a modified Level Set Method, is studied by Son and Dhir. Ose and Kunugi have developed a boiling and condensation model on subcooled boiling phenomena. Fuchs performed numerical simulations of bubble growth and departure considering wall conduction effects. Fully transient heat and fluid flow is modeled with a free surface of a rising bubble and a periodic calculation of the whole cycling of a growing, detaching, and rising bubble. Mukherjee and Kandikar have done a numerical simulation of an evaporating meniscus on a moving heated surface with level set method. The heat transfer associated with the advancing and receding contact angle has been studied. To develop the capability of physics-based boiling process, in the presented work the energy and momentum equations are coupled to simulate single-bubble growth scenarios. For a single bubble simulation in infinite liquid, the analytical solution exists and can be compared with the numerical results for verification purposes. The presented capabilities will be utilized in the large scale DNS of boiling flows in the future. The finite-element based code, PHASTA is used for the simulation. It is a parallel, hierarchic, higher-order accurate, adaptive, stabilized, transient analysis flow solver, which has been shown to be an effective tool for a wide range of single and two-phase flow problems. It has been shown to be highly scalable on top supercomputers ({approx}85% scaling on up to 3 million mesh partitions using a 92 billion element mesh . PHASTA has been shown to reliably predict the details of adiabatic bubbly flows as well as single-phase flows with heat transfer. To develop the capability of physics-based boiling process, in the presented work the energy and momentum equations are coupled to simulate a single-bubble growth scenario. For a single bubble growth in superheated water, the analytical solution exists and can be compared with the numerical results for verification purposes. The second-order accurate spatial and time discretization is used for the flow solver in the presented work. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SAPHIRE 8 Quality Assurance Software Metrics Report

The purpose of this review of software metrics is to examine the quality of the metrics gathered in the 2010 IV&V and to set an outline for results of updated metrics runs to be performed. We find from the review that the maintenance of accepted quality standards presented in the SAPHIRE 8 initial Independent Verification and Validation (IV&V) of April, 2010 is most easily achieved by continuing to utilize the tools used in that effort while adding a metric of bug tracking and resolution. Recommendations from the final IV&V were to continue periodic measurable metrics such as McCabe's complexity measure to ensure quality is maintained. The four software tools used to measure quality in the IV&V were CodeHealer, Coverage Validator, Memory Validator, Performance Validator, and Thread Validator. These are evaluated based on their capabilities. We attempted to run their latest revisions with the newer Delphi 2010 based SAPHIRE 8 code that has been developed and was successful with all of the Validator series of tools on small tests. Another recommendation from the IV&V was to incorporate a bug tracking and resolution metric. To improve our capability of producing this metric, we integrated our current web reporting system with the SpiraTest test management software purchased earlier this year to track requirements traceability.

97 MATHEMATICS AND COMPUTING↗

CFD Model Development and validation for High Temperature Gas Cooled Reactor Cavity Cooling System (RCCS) Applications

The Reactor Cavity Cooling Systems (RCCS) is a passive safety system that will be incorporated in the VTHR design. The system was designed to remove the heat from the reactor cavity and maintain the temperature of structures and concrete walls under desired limits during normal operation (steady-state) and accident scenarios. A small scale (1:23) water-cooled experimental facility was scaled, designed, and constructed in order to study the complex thermohydraulic phenomena taking place in the RCCS during steady-state and transient conditions. The facility represents a portion of the reactor vessel with nine stainless steel coolant risers and utilizes water as coolant. The facility was equipped with instrumentation to measure temperatures and flow rates and a general verification was completed during the shakedown. A model of the experimental facility was prepared using RELAP5-3D and simulations were performed to validate the scaling procedure. The experimental data produced during the steady-state run were compared with the simulation results obtained using RELAP5-3D. The overall behavior of the facility met the expectations. The facility capabilities were confirmed to be very promising in performing additional experimental tests, including flow visualization, and produce data for code validation.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

2D lag and signal nonlinearity correction in an amorphous silicon EPID and their impact on pretreatment dosimetric verification

Purpose: This investigation provides measurements of signal lag and nonlinearity separately for the Varian aS500 electronic portal imaging device (EPID), and an algorithm to correct for these effects in 2D; their potential impact on intensity modulated radiation therapy (IMRT) verification is also investigated. The authors quantify lag, as a function of both delivered monitor units (MU) and time, by using a range of MUs delivered at a clinically used rate of 400 MU/min. Explicit cumulative lag curves are thus determined for a range of MUs and times between the end of irradiation and the end of image acquisition. Signal nonlinearity is also investigated as a function of total MUs delivered. The family of cumulative lag curves and signal nonlinearity are then used to determine their effects on dynamic multileaf collimator (MLC) (IMRT) deliveries, and to correct for theses effects in 2D. Methods: Images acquired with an aS500 EPID and Varis Portal-Vision software were used to quantify detector lag and signal-nonlinearity. For the signal lag investigation, Portal-Vision's service monitor was used to acquire EPID images at a rate of 8 frames/s. The images were acquired during irradiation and 66 s thereafter, by inhibiting the M-holdoff-In signal of the Linac for a range of 4.5-198.5 MUs. Relative cumulative lag was calculated by integrating the EPID signal for a time after beam-off, and normalizing this to the integrated EPID signal accumulated during radiation. Signal nonlinearity was studied by acquiring 10 Multiplication-Sign 10 cm{sup 2} open-field EPID images in 'integrated image' mode for a range of 2-500 MUs, and normalized to the 100 MU case. All data were incorporated into in-house written software to create a 2D correction map for these effects, using the field's MLC file and a field-specific calculated 2D 'time-map,' which keeps track of the time elapsed from the last fluence delivered at each given point in the image to the end of the beam delivery. Results: Relative cumulative lag curves reveal that the lag alone can deviate the EPID's perceived dose by as large as 6% (1 MU delivery, 60 s postirradiation). For signal nonlinearity relative to 100 MU, EPID signals per MU of 0.84 and 1.01 were observed for 2 and 500 MUs, respectively. Correction maps were applied to a 1 cm sweeping-window 14 Multiplication-Sign 14 cm{sup 2} field and clinical head-and-neck IMRT field. A mean correction of 1.028 was implemented in the head-and-neck field, which significantly reduced lag-related asymmetries in the EPID images, and restored linearity to the EPID imager's dose response. Corrections made to the sweeping-field showed good agreement with the treatment planning system-predicted field, yielding an average percent difference of 0.05%{+-} 0.91%, compared to the -1.32%{+-} 1.02% before corrections, or 1.75%{+-} 1.04% when only a signal nonlinearity correction is made. Conclusions: Lag and signal-nonlinearity have been quantified for an aS500 EPID imager, and an effective 2D correction method has been developed which effectively removes nonlinearity and lag effects. Both of these effects were shown to negatively impact IMRT verifications. Especially fields that involve prolonged irradiation and small overall MUs should be corrected for in 2D.

60 APPLIED LIFE SCIENCES↗

Digital tomosynthesis (DTS) for verification of target position in early stage lung cancer patients

Purpose: The ability to verify intrafraction tumor position is clinically useful for hypofractionated treatments. Short arc kV digital tomosynthesis (DTS) could facilitate more frequent target verification. The authors used DTS combined with triangulation to determine the mean temporal position of small-volume lung tumor targets treated with stereotactic radiotherapy. DTS registration results were benchmarked against online clinical localization using registration between free-breathing cone-beam computed tomography (CBCT) and the average intensity projection (AvIP) of the planning 4DCT.Methods: In this retrospective study, 76 sets of kV-projection images from online CBCT scans of 13 patients were used to generate DTS image slices (CB-DTS) with nonclinical research software (DTS Toolkit, Varian Medical Systems). Three-dimensional tumor motion was 1.3–4 mm in six patients and 6.1–25.4 mm in seven patients on 4DCT (significant difference in the mean of the groups, P < 0.01). The 4DCT AvIP was used to digitally reconstruct the Reference-DTS. DTS registration and DTS registration combined with triangulation were investigated. Progressive shortening of total DTS arc lengths from 95° to 35° around 0° gantry position was evaluated for different scenarios: DTS registration using the entire arc; DTS registration plus triangulation using two nonoverlapping arcs; and for 55° and 45° total gantry rotation, DTS registration plus triangulation using two overlapping arcs. Finally, DTS registration plus triangulation performed at eight gantry angles, each separated by 45° was evaluated using full fan kV projection data for one patient with an immobile tumor and five patients with mobile tumors.Results: For DTS registration alone, shortening arc length did not influence accuracy in X- and Y-directions, but in Z-direction, mean deviations from online CBCT localization systematically increased for shorter arc length (P < 0.05). For example, using a 95° arc mean DTS-CBCT difference was 0.8 mm (1 SD = 0.6 mm) and for a 35° arc the mean was 2.4 mm (1 SD = 1.7 mm). DTS plus triangulation using nonoverlapping-arcs increased accuracy in Z-direction for tested arc lengths ≤55° (P < 0.01). Overlapping arcs increased accuracy in Y-direction for tumors with motion >4 mm (P < 0.02) but increased Z-direction accuracy was only observed with 55° total gantry rotation. The 95th percentile deviations with this overlapping technique in X-, Y-, and Z-directions were 1.3, 2.0, and 2.5 mm, respectively. For the five patients with mobile tumors where DTS + triangulation was performed with 45° intervals, the pooled deviation from online CBCT correction showed, for X-, Y-, and Z-directions, mean of 1.1 mm, standard deviations (SD) of 0.9, 1.0, and 0.9 mm, respectively. The mean + 2 SD was <3 mm for each direction.Conclusions: Short-arc DTS verification of time averaged lung tumor position is feasible using free-breathing kV projection data and the AvIP of the 4DCT as a reference. Observed differences between DTS and online CBCT registration with AvIP were ≤3 mm (mean + 2 SD), however, the increased temporal resolution of DTS + triangulation also identified short period deviations from the average target position on the CBCT. Short-arc DTS appears promising for intrafraction tumor position monitoring during stereotactic lung radiotherapy delivered with a rotational technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗