Search NASA⌕ Search

SEARCH · Search NASA

Results for “comparators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Comparative studies of 2HDMs under the Higgs boson precision measurements

We perform comparative studies for four types of the two Higgs Doublet Models (2HDMs) under the precision measurements of the Standard Model (SM) Higgs observables at the proposed Higgs factories. We explore the discovery potential based on the hypothetical deviations in the precision data for the 2HDMs up to one-loop level. We find 5σ observability from the χ2 fitting in a significant theory parameter space at future Higgs factories. For the Type-I 2HDM, regions with cos(β - α) ≲ -0.1 or cos(β - α) ≳ 0.08 are discoverable at more than 5σ level. For the other three types of 2HDMs, the 5σ region is even bigger: | cos(β - α)| ≳ 0.02 for tan β ~ 1. At small and large values of tan β, the region in cos(β - α) is further tightened. We examine the extent to which the different 2HDM theories may be distinguishable from one to the other at the 95% Confidence Level with four benchmark points as case studies. We show that a large part of the parameter space of the other types of 2HDMs can be distinguished from the benchmark points of the target model. The impacts of loop corrections are found to be significant in certain parameter regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comparing elliptic and toric hypersurface Calabi-Yau threefolds at large Hodge numbers

We compare the sets of Calabi-Yau threefolds with large Hodge numbers that are constructed using toric hypersurface methods with those can be constructed as elliptic fibrations using Weierstrass model techniques motivated by F-theory. There is a close correspondence between the structure of “tops” in the toric polytope construction and Tate form tunings of Weierstrass models for elliptic fibrations. We find that all of the Hodge number pairs ( h 1,1 , h 2,1 ) with h 1,1 or h 2,1 ≥ 240 that are associated with threefolds in the Kreuzer-Skarke database can be realized explicitly by generic or tuned Weierstrass/Tate models for elliptic fibrations over complex base surfaces. This includes a relatively small number of somewhat exotic constructions, including elliptic fibrations over non-toric bases, models with new Tate tunings that can give rise to exotic matter in the 6D F-theory picture, tunings of gauge groups over non-toric curves, tunings with very large Hodge number shifts and associated nonabelian gauge groups, and tuned Mordell-Weil sections associated with U(1) factors in the corresponding 6D theory.

43 PARTICLE ACCELERATORS↗

A comparative study of Higgs boson production from vector-boson fusion

The data taken in Run II at the Large Hadron Collider have started to probe Higgs boson production at high transverse momentum. Future data will provide a large sample of events with boosted Higgs boson topologies, allowing for a detailed understanding of electroweak Higgs boson plus two-jet production, and in particular the vector-boson fusion mode (VBF). We perform a detailed comparison of precision calculations for Higgs boson production in this channel, with particular emphasis on large Higgs boson transverse momenta, and on the jet radius dependence of the cross section. We study fixed-order predictions at next-to-leading order and next-to-next-to-leading order QCD, and compare the results to NLO plus parton shower (NLOPS) matched calculations. The impact of the NNLO corrections on the central predictions is mild, with inclusive scale uncertainties of the order of a few percent, which can increase with the imposition of kinematic cuts. We find good agreement between the fixed-order and matched calculations in non-Sudakov regions, and the various NLOPS predictions also agree well in the Sudakov regime. We analyze backgrounds to VBF Higgs boson production stemming from associated production, and from gluon-gluon fusion. At high Higgs boson transverse momenta, the Δy$_{jj}$ and/or m$_{jj}$ cuts typically used to enhance the VBF signal over background lead to a reduced efficiency. We examine this effect as a function of the jet radius and using different definitions of the tagging jets. QCD radiative corrections increase for all Higgs production modes with increasing Higgs boson p$_{T}$, but the proportionately larger increase in the gluon fusion channel results in a decrease of the gluon-gluon fusion background to electroweak Higgs plus two jet production upon requiring exclusive two-jet topologies. We study this effect in detail and contrast in particular a central jet veto with a global jet multiplicity requirement.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Developing a Consistent Travel-Time Framework for Comparing Three-Dimensional Velocity Models for Seismic Location Accuracy

Abstract Location algorithms have historically relied on simple, one-dimensional (1D) velocity models for fast seismic event locations. 1D models are generally used as travel-time lookup tables, one for each seismic phase, with travel-times pre-calculated for event distance and depth. These travel-time lookup tables are extremely fast to use and this fast computational speed makes them the preferred type of velocity model for operational needs. Higher-dimensional (i.e., three-dimensional—3D) seismic velocity models are becoming readily available and provide more accurate event locations over 1D models. The computational requirements of these 3D models tend to make their operational use prohibitive. Additionally, comparing location accuracy for 3D seismic velocity models tends to be problematic, as each model is determined using different ray-tracing algorithms. Attempting to use a different algorithm than the one used to develop a model usually results in poor travel-time prediction. We demonstrate and test a framework to create first-P and first-S 3D travel-time correction surfaces using an open-source framework ( PCalc + GeoTess , https://www.sandia.gov/salsa3d/software/geotess ) that easily stores 3D travel-time and uncertainty data. This framework produces fast travel-time and uncertainty predictions and overcomes the ray-tracing algorithm hurdle because the lookup tables can be generated using the exact ray-tracing algorithm that is preferred for a model.

3D velocity models↗

Comparing the effect of virtual and in-person instruction on students’ performance in a design for additive manufacturing learning activity

The goal of this work is to compare the outcome of a design for additive manufacturing (DfAM) heuristics lesson conducted in a virtual learning environment to the same in an in-person learning environment. Prior work revealed that receiving DfAM heuristics at different points in the design process impacts the quality and novelty of designs produced afterward, but this work may have been limited by the solely virtual format. In this work, an identical experiment was performed in a face-to-face learning environment. Results indicate that neither learning format presents an advantage over the other when it comes to the quality of designs produced during the intervention. Participants across all experimental groups reported an increase in self-efficacy after the intervention, with improved performance on quiz-type questions. Furthermore, the novelty and variety of the designs produced by the in-person experimental groups were significantly lower than that of the virtual experimental groups. In addition to validating the effectiveness of virtual instruction as a teaching method, these results also support the authors’ hypothesis that the priming effect is stronger in an in-person classroom than in a virtual classroom.

Design for additive manufacturing↗

Comparing Transcriptomic Points of Departure to Apical Effect Concentrations For Larval Fathead Minnow Exposed to Chemicals with Four Different Modes Of Action

It is postulated that below a transcriptomic-based point of departure, adverse effects are unlikely to occur, thereby providing a chemical concentration to use in screening level hazard assessment. The present study extends previous work describing a high-throughput fathead minnow assay that can provide full transcriptomic data after exposure to a test chemical. One-day post-hatch fathead minnows were exposed to ten concentrations of three representatives of four chemical modes of action: organophosphates, ecdysone receptor agonists, plant photosystem II inhibitors, and estrogen receptor agonists for 24 h. Concentration response modeling was performed on whole body gene expression data from each exposure, using measured chemical concentrations when available. Transcriptomic points of departure in larval fathead minnow were lower than apical effect concentrations across fish species but not always lower than toxic effect concentrations in other aquatic taxa like crustaceans and insects. The point of departure was highly dependent on measured chemical concentration which were often lower than the nominal concentration. Differentially expressed genes between chemicals within modes of action were compared and often showed statistically significant overlap. In addition, reproducibility between identical exposures using a positive control chemical (CuSO 4 ) and variability associated with the transcriptomic point of departure using in silico sampling were considered. Results extend a transcriptomic-compatible fathead minnow high-throughput assay for possible use in ecological hazard screening.

59 BASIC BIOLOGICAL SCIENCES↗

Comparative accuracy of qualitative and quantitative 18F-FDG PET/CT analysis in detection of lymph node metastasis from anal cancer

Purpose: To compare the diagnostic performance of qualitative and quantitative 18F-FDG PET/CT in detection of regional and distant lymph node metastasis in patients with anal cancer. Methods: Between 2004 and 2017, 28 patients with anal cancer who had staging PET/CT and pathological assessment of suspicious lymph nodes were included. For qualitative analysis, positive lymph nodes were defined as uptake visually higher than the liver reference uptake. For quantitative study, lymph nodes were contoured to determine maximum standard uptake value (SUV{sub max}) and metabolic tumor volume (MTV). Receiver operating characteristic (ROC) curves were plotted to extract the optimal cut-offs and area under the curve (AUC) of SUV{sub max}, lesion to background (L/B) ratio, short axis diameter (SAD), and MTV of lymph nodes. Histopathologic analysis was a reference standard. Results: A total of 28 lymph nodes (24 inguinal, 2 external iliac, 1 internal iliac, and 1 paraaortic nodes) in 28 patients on PET/CT were included. With the qualitative visual analysis, 19 patients were categorized as positive for nodal metastasis with sensitivity, specificity, and accuracy of 85%, 75%, and 82%. The optimal SUV{sub max} and L/B ratio cut-offs were 2.6 and 1.0 with both sensitivity and specificity of 95% and 75% (AUC of SUV{sub max} = 0.893, AUC of L/B ratio = 0.912). Using the best cut-off of 1.6 cm for SAD and 3.65 cm{sup 3} for MTV, both sensitivity and specificity were 80% and 100% (AUC of SAD = 0.950, AUC of MTV = 0.931). Conclusions: SUV{sub max} optimization may be helpful in enhancing the diagnostic accuracy of 18F-FDG PET/CT in nodal staging patients with anal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing Scales of Environmental Effects from Gasoline and Ethanol Production

Understanding the environmental effects of alternative fuel production is critical to characterizing the sustainability of energy resources to inform policy and regulatory decisions. The magnitudes of these environmental effects vary according to the intensity and scale of fuel production along each step of the supply chain. We compare the scales (i.e., spatial extent and temporal duration) of ethanol and gasoline production processes and environmental effects based on a literature review, and then synthesize the scale differences on space-time diagrams. Comprehensive assessment of any fuel-production system is a moving target, and our analysis shows that decisions regarding the selection of spatial and temporal boundaries of analysis have tremendous influences on the comparisons. Effects that strongly differentiate gasoline and ethanol supply chains in terms of scale are associated with when and where energy resources are formed and how they are extracted. Although both gasoline and ethanol production may result in negative environmental effects, this study indicates that ethanol production traced through a supply chain may impact less area and result in more easily reversed effects of a shorter duration than gasoline production.

biofuel↗

Detection of Cement Leakage After Vertebroplasty with a Non-Flat-Panel Angio Unit Compared to Multidetector Computed Tomography - An Ex Vivo Study

The purpose of this study was to investigate the detection of cement leakages after vertebroplasty using angiographic computed tomography (ACT) in a non-flat-panel angio unit compared to multidetector computed tomography (MDCT). Vertebroplasty was performed in 19 of 33 cadaver vertebrae (23 thoracic and 10 lumbar segments). In the angio suite, ACT (190{sup o}; 1.5{sup o} per image) was performed to obtain volumetric data. Another volumetric data set of the specimen was obtained by MDCT using a standard algorithm. Nine multiplanar reconstructions in standardized axial, coronal, and sagittal planes of every vertebra were generated from both data sets. Images were evaluated on the basis of a nominal scale with 18 criteria, comprising osseous properties (e.g., integrity of the end plate) and cement distribution (e.g., presence of intraspinal cement). MDCT images were regarded as gold standard and analyzed by two readers in a consensus mode. Rotational acquisitions were analyzed by six blinded readers. Results were correlated with the gold standard using Cohen's {kappa}-coefficient analysis. Furthermore, interobserver variability was calculated. Correlation with the gold standard ranged from no correlation (osseous margins of the neuroforamen, {kappa} = 0.008) to intermediate (trace of vertebroplasty canula; {kappa} = 0.615) for criteria referring to osseous morphology. However, there was an excellent correlation for those criteria referring to cement distribution, with {kappa} values ranging from 0.948 (paravertebral cement distribution) to 0.972 (intraspinal cement distribution). With a minimum of {kappa} = 0.768 ('good correlation') and a maximum of {kappa} = 0.91 ('excellent'), interobserver variability was low. In conclusion, ACT in an angio suite without a flat-panel detector depicts a cement leakage after vertebroplasty as well as MDCT. However, the method does not provide sufficient depiction of osseous morphology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Outcomes of Patients with Lumbar Disc Herniation Treated with Percutaneous Discectomy: Comparative Study with Microendoscopic Discectomy

We assessed the long-term outcomes of patients with lumbar disc herniation treated with percutaneous lumbar discectomy (PLD) or microendoscopic discectomy (MED). A retrospective study was performed in consecutive patients with lumbar disc herniation treated with PLD (n = 129) or MED (n = 101) in a single hospital from January 2000 to March 2002. All patients were followed up with MacNab criteria and self-evaluation questionnaires comprising the Oswestry Disability Index and Medical Outcomes Study 36-Item Short-Form Health Survey. Several statistical methods were used for analyses of the data, and a p value of <0.05 was considered to be statistically significant. A total of 104 patients (80.62%) with PLD and 82 patients (81.19%) with MED were eligible for analyses, with a mean follow-up period of 6.64 {+-} 0.67 years and 6.42 {+-} 0.51 years, respectively. There were no significant differences between the two groups in age, number of lesions, major symptoms and physical signs, and radiological findings. According to the MacNab criteria, 75.96% in the PLD group and 84.15% in the MED group achieved excellent or good results, respectively, this was statistically significant (p = 0.0402). With the Oswestry Disability Index questionnaires, the average scores and minimal disability, respectively, were 6.97 and 71.15% in the PLD group and 4.89 and 79.27% in the MED group. Total average scores of Medical Outcomes Study 36-Item Short-Form Health Survey were 75.88 vs. 81.86 in PLD group vs. MED group (p = 0.0582). The cost and length of hospitalization were higher or longer in MED group, a statistically significant difference (both p < 0.0001). Long-term complications were observed in two patients (2.44%) in the MED group, no such complications were observed in the PLD group. Both PLD and MED show an acceptable long-term efficacy for treatment of lumbar disc herniation. Compared with MED patients, long-term satisfaction is slightly lower in the PLD patients; complications, hospitalization duration, and costs in PLD group are also lower.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Subclavian Vein Versus Arm Vein for Totally Implantable Central Venous Port for Patients with Head and Neck Cancer: A Retrospective Comparative Analysis

Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access-the subclavian vein and arm vein-in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achieved in all patients. The median follow-up period was 94 (range, 1-891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Standard Pushable Coils with Fibered Interlock Detachable Coils

The purpose of this study was compare embolization of the gastroduodenal artery (GDA) using standard pushable coils with the Interlock detachable coil (IDC), a novel fibered mechanically detachable long microcoil, in patients scheduled for selective internal radiotherapy (SIRT). Fifty patients (31 male and 19 female; median age 66.6 {+-} 8.1 years) were prospectively randomized for embolization using either standard coils or IDCs. Procedure time, radiation dose, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography were recorded. The procedures differed significantly in time (14:32 {+-} 5:56 min for standard coils vs. 2:13 {+-} 1:04 min for IDCs; p < 0.001); radiation dose for coil deployment (2479 {+-} 1237 cGycm Superscript-Two for standard coils vs. 275 {+-} 268 cGycm Superscript-Two for IDCs; p < 0.001); and vessel occlusion (17:18 {+-} 6:39 min for standard coils vs. 11:19 {+-} 7:54 min for IDCs; p = 0.002). A mean of 6.2 {+-} 1.8 coils (n = 27) were used in the standard coil group, and 1.3 {+-} 0.9 coils (p < 0.0001) were used in the IDC group (n = 23) because additional pushable coils were required to achieve GDA occlusion in 4 patients. In 2 patients, the IDC could not be deployed through a Soft-VU catheter. One standard coil dislodged in the hepatic artery and was retrieved. Vessel reperfusion was noted in only 1 patient in the standard coil group. Controlled embolization of the GDA with fibered IDCs was achieved more rapidly than with pushable coils. However, vessel occlusion may not be obtained using a single device only, and the use of sharply angled guiding catheters hampered coil pushability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Safety and Effectiveness of Percutaneously Inserted Peritoneal Ports Compared to Surgically Inserted Ports in a Retrospective Study of 87 Patients with Ovarian Carcinoma over a 10-Year Period

PurposePlacement of peritoneal ports has become a favorable technique for direct chemotherapy infusion in treating peritoneal metastases from ovarian cancer. We aim to outline an approach to the percutaneous insertion of peritoneal ports and to characterize success and complication rates compared to surgically inserted ports.Materials and MethodsRetrospective analysis was collected from 87 patients who had peritoneal port insertion (28 inserted surgically and 59 percutaneously) for treatment of peritoneal metastases from ovarian cancer from July 2004 to July 2014. Complications were classified according to the SIR Clinical Practice Guidelines as major or minor.ResultsTechnical success rates for surgically and percutaneously inserted ports were 100 and 96.7 %, respectively (p = 0.44), with the two percutaneous failures successful at a later date. There were no major complications in either group. Minor complication rates for surgically versus percutaneously inserted ports were 46.4 versus 22.0 %, respectively (p = 0.02). The infection rate for surgically inserted versus percutaneously inserted ports was 14.3 and 0 %, respectively (p = 0.002). The relative risk of developing a complication from percutaneous peritoneal port insertion without ascites was 3.4 (p = 0.04). For percutaneously inserted ports, the mean in-room procedure time was 81 ± 1.3 min and mean fluoroscopy time was 5.0 ± 4.5 min.ConclusionPercutaneously inserted peritoneal ports are a safe alternative to surgically inserted ports, demonstrating similar technical success and lower complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparing published scientific journal articles to their pre-print versions

Academic publishers claim that they add value to scholarly communications by coordinating reviews and contributing and enhancing text during publication. These contributions come at a considerable cost: US academic libraries paid $1.7 billion for serial subscriptions in 2008 alone. Library budgets, in contrast, are flat and not able to keep pace with serial price inflation. Here, we have investigated the publishers’ value proposition by conducting a comparative study of pre-print papers from two distinct science, technology, and medicine corpora and their final published counterparts. This comparison had two working assumptions: (1) If the publishers’ argument is valid, the text of a pre-print paper should vary measurably from its corresponding final published version, and (2) by applying standard similarity measures, we should be able to detect and quantify such differences. Our analysis revealed that the text contents of the scientific papers generally changed very little from their pre-print to final published versions. These findings contribute empirical indicators to discussions of the added value of commercial publishers and therefore should influence libraries’ economic decisions regarding access to scholarly publications.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Soil carbon sensitivity to temperature and carbon use efficiency compared across microbial-ecosystem models of varying complexity

Global ecosystem models may require microbial components to accurately predict feedbacks between climate warming and soil decomposition, but it is unclear what parameters and levels of complexity are ideal for scaling up to the globe. Here we conducted a model comparison using a conventional model with first-order decay and three microbial models of increasing complexity that simulate short- to long-term soil carbon dynamics. We focused on soil carbon responses to microbial carbon use efficiency (CUE) and temperature. Three scenarios were implemented in all models: constant CUE (held at 0.31), varied CUE ( 0.016 C 1), and 50 % acclimated CUE ( 0.008 C 1). Whereas the conventional model always showed soil carbon losses with increasing temperature, the microbial models each predicted a temperature threshold above which warming led to soil carbon gain. The location of this threshold depended on CUE scenario, with higher temperature thresholds under the acclimated and constant scenarios. This result suggests that the temperature sensitivity of CUE and the structure of the soil carbon model together regulate the long-term soil carbon response to warming. Equilibrium soil carbon stocks predicted by the microbial models were much less sensitive to changing inputs compared to the conventional model. Although many soil carbon dynamics were similar across microbial models, the most complex model showed less pronounced oscillations. Thus, adding model complexity (i.e. including enzyme pools) could improve the mechanistic representation of soil carbon dynamics during the transient phase in certain ecosystems. This study suggests that model structure and CUE parameterization should be carefully evaluated when scaling up microbial models to ecosystems and the globe.

Li, Jianwei↗

Benefits of mitigation for future heat extremes under RCP4.5 compared to RCP8.5

We investigate changes in statistics of extreme daily temperature using ensembles from the Community Earth System Model (CESM) under a high and a lower emission scenarios, . The ensembles provide large samples for a robust application of extreme value theory. We estimate return values and return periods for annual maxima of the daily high and low temperatures as well as the 3-day averages of the same variables in current and future climate. Results indicate statistically significant increases (compared to the reference period of 1996–2005) in extreme temperatures over all land areas as early as 2025 under both scenarios, with statistically significant differences between them becoming pervasive over the globe by 2050. The substantially smaller changes, for all indices, produced under the lower emission case translate into sizeable benefits from emission mitigation: By 2075, in terms of reduced changes in 1-day heat extremes, about 95 % of land regions would see benefits of 1 °C or more under the lower emissions scenario, and 50 % or more of the land areas would benefit by at least 2 °C. 6 % of the land area would benefit by 3 °C or more in projected extreme minimum temperatures and 13 % would benefit by this amount for extreme maximum temperature. Benefits for 3-day metrics are similar. The future frequency of current extremes is also greatly reduced by mitigation: by the end of the century, under RCP8.5 more than half the land area experiences the current 20-year events every year while only between about 10 and 25 % of the area is affected by such severe changes under RCP4.5.

54 ENVIRONMENTAL SCIENCES↗

A comparative study of thermal- and electrocatalytic conversion of furfural: methylfuran as a primary and major product

Controlling reaction selectivity represents a fundamental challenge in heterogeneous catalysis. Here, we compare the selectivity in aqueous-phase thermal catalytic and electrocatalytic conversion of furfural and report the fundamental difference in elementary steps in the two reaction systems. Specifically, we observed that furfural alcohol and 2-methylfuran, which is the hydrogenation and hydrogenolysis product of furfural, respectively, are both primary products in electrocatalysis over a Cu electrode, with 2-methylfuran dominating the product distribution under electrode potentials between -0.55 and -0.75 V versus RHE. By contrast, in an aqueous-phase thermal reaction using a SiO 2 -supported Cu catalyst, furfural alcohol and its derivatives from the ring-rearrangement reaction are the major products, without production of 2-methylfuran, at the reaction temperature between 140 and 200 °C. Here, we propose that the distinct selectivity trends for oxygenate conversion via thermal and electrocatalytic reduction result from the distinct sequence of proton attack to the aldehyde group and may be generally true for reduction reactions of other biomass-derived oxygenates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A universal method to compare parts from STEP files

Abstract Model Based Definition (MBD) captures the complete specification of a part in digital form and leverages (at least) the universal “Standard for the Exchange of Product” (STEP) file format. MBD has revolutionized manufacturing due to time and cost savings associated with containing all engineering data within a single digital source. This work presents a novel method to transform digital definitions in any given STEP file into a tensor-like structure that is unique for each part and can be used to regenerate the original STEP file completely. Resulting STEP tensors are amenable to part comparison based on various part specifications in a general and straightforward manner. Here, part similarity is evaluated among sets of parts according to specific geometry, material composition, and design intent. Importantly, specification similarity can be quantified using only the tensors’ structure. As such, this approach is not limited to families of geometric shapes, part types, or fabrication methods; nor does it require any prior knowledge about the parts being compared.

36 MATERIALS SCIENCE↗