Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Phenomenological study on correlation between flow harmonics and mean transverse momentum in nuclear collisions

To assess the properties of the quark-gluon plasma formed in nuclear collisions, the Pearson correlation coefficient between flow harmonics and mean transverse momentum, \rho\left(v_{n}^{2},\left[p_{\mathrm{T}}\right]\right) ρ ( v n 2 , [ p T ] ) , reflecting the overlapped geometry of colliding atomic nuclei, is measured. \rho\left(v_{2}^{2},\left[p_{\mathrm{T}}\right]\right) ρ ( v 2 2 , [ p T ] ) was found to be particularly sensitive to the quadrupole deformation of the nuclei. We study the influence of the nuclear quadrupole deformation on \rho\left(v_{n}^{2},\left[p_{\mathrm{T}}\right]\right) ρ ( v n 2 , [ p T ] ) in Au+Au and U+U collisions at RHIC energy using AMPT transport model, and show that the \rho\left(v_{2}^{2},\left[p_{\mathrm{T}}\right]\right) ρ ( v 2 2 , [ p T ] ) is reduced by the quadrupole deformation \beta_2 β 2 and turns to change sign in ultra-central collisions (UCC).

Zhang, Chunjian↗

Use Case Realization Report: UCR-03.02.08 Compares Events

This architecturally significant use case describes how the Analyst compares events to determine how similar events were constructed. The Analyst compares waveforms from comparison events by visually inspecting an overlay of the waveforms to determine if the events are from a similar source. The Analyst searches for comparison events or creates agglomerative hierarchical clusters of waveforms from events and determines that the events are from a similar source if the correlation coefficient is above a selected threshold. This use case is architecturally significant due to the introduction of the capability to compare events within an operational context.

97 MATHEMATICS AND COMPUTING↗

Arctic Clouds Infrared Imaging Field Campaign Report

The Infrared Cloud Imager (ICI), a passive thermal imaging system, was deployed at the North Slope of Alaska site in Barrow, Alaska, from July 2012 to July 2014 for measuring spatial-temporal cloud statistics. Thermal imaging of the sky from the ground provides high radiometric contrast during night and polar winter when visible sensors and downward-viewing thermal sensors experience low contrast. In addition to demonstrating successful operation in the Arctic for an extended period and providing data for Arctic cloud studies, a primary objective of this deployment was to validate novel instrument calibration algorithms that will allow more compact ICI instruments to be deployed without the added expense, weight, size, and operational difficulty of a large-aperture onboard blackbody calibration source. This objective was successfully completed with a comparison of the two-year data set calibrated with and without the onboard blackbody. The two different calibration methods produced daily-average cloud amount data sets with correlation coefficient = 0.99, mean difference = 0.0029 (i.e., 0.29% cloudiness), and a difference standard deviation = 0.054. Finally, the ICI instrument generally detected more thin clouds than reported by other ARM cloud products available as of late 2015.

54 ENVIRONMENTAL SCIENCES↗

Assimilation of Wave Imaging Radar Observations for Real-time Wave-by-Wave Forecasting

This project addressed Topic 3: “Wave Measurement Instrumentation for Feed Forward Controls” under the FOA number DE-FOA-0000971. The overall goal of the program was to develop a phase-resolving wave forecasting technique for application to the active control of Wave Energy Conversion (WEC) devices. We have developed an approach that couples a wave imaging marine radar with a phase-resolving linear wave model for real-time wave field reconstruction and forward propagation of the wave field in space and time. The scope of the project was to develop and assess the performance of this novel forecasting system. Specific project goals were as follows: Develop and verify a fast, GPU-based (Graphical Processing Unit) wave propagation model suitable for phase-resolved computation of nearshore wave transformation over variable bathymetry; Compare the accuracy and speed of performance of the wave model against a deep water model in their ability to predict wave field transformation in the intermediate water depths (50 to 70 m) typical of planned WEC sites; Develop and implement a variational assimilation algorithm that can ingest wave imaging radar observations and estimate the time-varying wave conditions offshore of the domain of interest such that the observed wave field is best reconstructed throughout the domain and then use this to produce model forecasts for a given WEC location; Collect wave-resolving marine radar data, along with relevant in situ wave data, at a suitable wave energy test site, apply the algorithm to the field data, assess performance, and identify any necessary improvements; and Develop a production cost estimate that addresses the affordability of the wave forecasting technology and include in the Final Report. The developed forecasting algorithm (“Wavecast”) was evaluated for both speed and accuracy against a substantial synthetic dataset. Early in the project, performance tests definitively demonstrated that the system was capable of forecasting in real-time, as the GPU-based wave model backbone was very computationally efficient. The data assimilation algorithm was developed on a polar grid domain in order to match the sampling characteristics of the observation system (wave imaging marine radar). For verification purposes, a substantial set of synthetic wave data (i.e. forward runs of the wave model) were generated to be used as ground truth for comparison to the reconstructions and forecasts produced by Wavecast. For these synthetic cases, Wavecast demonstrated very good accuracy, for example, typical forecast correlation coefficients were between 0.84-0.95 when compared to the input data. Dependencies on shadowing, observational noise, and forecast horizon were also identified. During the second year of the project, a short field deployment was conducted in order to assess forecast accuracy under field conditions. For this, a radar was installed on a fishing vessel and observations were collected at the South Energy Test Site (SETS) off the coast of Newport, OR. At the SETS site, simultaneous in situ wave observations were also available owing to an ongoing field project funded separately. Unfortunately, the position and heading information that was available for the fishing vessel were not of sufficient accuracy in order to validate the forecast in a phase-resolving sense. Instead, a spectral comparison was made between the Wavecast forecast and the data from the in situ wave buoy. Although the wave and wind conditions during the field test were complex, the comparison showed a promising reconstruction of the wave spectral shape, where both peaks in the bimodal spectrum were represented. However, the total reconstructed spectral energy (across all directions and frequencies) was limited to 44% of the observed spectrum. Overall, wave-by-wave forecasting using a data assimilation approach based on wave imaging radar observations and a physics-based wave model shows promise for short-term phase-resolved predictions. Two recommendations for future work are as follows: first, we would recommend additional focused field campaigns for algorithm validation. The field campaign should be long enough to capture a range of wave conditions relevant to the target application and WEC site. In addition, it will be crucial to make sure the vessel of choice has high accuracy position and heading instrumentation (this instrumentation is commercially available but not standard on commercial fishing vessels). The second recommendation is to expand the model physics in the wave model backbone to include some nonlinear effects. Specifically, the third-order correction to the wave speed due to amplitude dispersion would be the next step in order to more accurately represent the phase speeds of large amplitude waves.

16 TIDAL AND WAVE POWER↗

Genetic Algorithm for Hyperparameter Optimization in Gaussian Process Modeling

A genetic algorithm is developed and applied to optimize hyperparameters of convolutional recursively determined dual neural network-Gaussian process (NNGP) kernels. As a specific application of the combined GPNN-GA algorithm, it is applied to image classification in publicly available data of Hyper Suprime-Cam Subaru Strategic Program. Matthews correlation coefficient is calculated based on results of binary star-galaxy classification and used as a fitting function of the GA module of the algorithm. The simulation results confirm significant improvement of the classification accuracy with optimized hyperparameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Nuclear Data and Cross Section Testing Using ENDF/B-VIII.0

With the release of the Evaluated Nuclear Data File (ENDF)/B-VIII.0 library, nuclear criticality safety practitioners and engineers have access to the latest cross section sets available for their analyses. However, these cross sections must be rigorously tested and validated to ensure that the nuclear data are responsive to the needs of the individuals responsible for developing, implementing, and maintaining computational tools for criticality safety applications. Thus, the ENDF/B-VIII.0 library is tested and validated with a large collection of experiments that were vetted by the International Criticality Safety Benchmark Evaluation Project and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments. A selection of benchmark experiments for use within the criticality safety community were prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID), which is maintained by the Nuclear Energy and Fuel Cycle Division at Oak Ridge National Laboratory. The performance of the ENDF/B-VIII.0 library is assessed by using VALID models of benchmark experiments with the beta 12 version of SCALE 6.3 KENO V.a and KENO-VI Monte Carlo codes. The performance is compared with the results obtained from with the ENDF/B-VII.1 library. This report considers multigroup (MG) and continuous energy (CE) formats of the ENDF/B-VIII.0 and -VII.1 libraries. The benchmark experiments within VALID that validate the ENDF/B-VIII.0 library cover 15 broad system categories by using a range of fissile materials, uranium enrichments, plutonium isotopic vectors, and mixed uranium/plutonium systems. These forms are represented as metals, solutions, or various arrays of rods or plates that cover a variety of neutron energy spectra: thermal, fast, mixed, and intermediate. Over 600 cases were considered for use with the KENO V.a and KENO-VI codes with the ENDF/B-VIII.0 library. The results of the Monte Carlo comparison of ENDF/B-VIII.0 to ENDF/B-VII.1 with both KENO V.a and KENO-VI indicate that there is a less than 0.53% Δk difference between the bias of calculated k eff from the expected values. The CE ENDF/B-VIII.0 library results in smaller magnitude biases than the ENDF/B-VII.1 data for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-SOL-THERM, PU-SOL-THERM, and U233-MET-FAST systems, while the MG results yielded smaller magnitude biases for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-COMP-THERM, LEU-SOL THERM, MIX-COMP-FAST, and U233-MET-FAST systems. Most notable are the adjustments to the plutonium and 233 U cross section data, which has resulted in noticeably lower biases in the ENDF/B VIII.0 results for the mixed, plutonium, and 233 U systems. Results of the sensitivity data file comparison generated from TSUNAMI-3D for selected VALID cases for the ENDF/B-VIII.0 library indicate a very high level of agreement with correlation coefficients of the effect of nuclear data uncertainty on k eff (the c k integral parameter) all above 0.99. This indicates that cases with the ENDF/B-VIII.0 library would see very similar responses to any nuclear data errors or change as those with the ENDF/B-VII.1 library.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation of the High-Resolution Salish Sea Tidal Hydrodynamic Model

In this study, a tidal hydrodynamic model was developed and validated to simulate tidal currents in Puget Sound, Washington, to support tidal energy resource characterization using the unstructured-grid, Finite Volume Community Ocean Model (FVCOM). The Salish Sea tidal hydrodynamic model was driven by tides along two open boundaries at the entrance of the Strait of Juan de Fuca and north end of Georgia Strait, and river flows from 19 major rivers in the Salish Sea. To simulate the tidal current in Puget Sound, a high-resolution model grid is required to accurately represent the complex coastlines and bathymetry. The spatial resolution of the model grid varies from ~10 m near river boundaries and ~30 m in small tidal channels and estuaries to near 1000 m inside Georgia Strait and at the open boundaries. Model validation was carried out by comparing simulated and observed water levels at 12 tidal stations and currents at 135 Acoustic Doppler Current Profiler stations in the model domain. A set of model performance metrics, including root mean square error, scatter index, bias, and linear correlation coefficient, were used to quantify the model skills in simulating the tidal hydrodynamics in Puget Sound. Error statistics showed an overall good agreement between simulated and observed tidal elevations and currents, which demonstrated that the Puget Sound tidal model can be used to accurately characterize the tidal stream energy resource in Puget Sound.

16 TIDAL AND WAVE POWER↗

Verification Testing of OLI Systems Mixed Solvent Electrolyte Model for the Na-K-Mg-Ca-H-Cl-SO 4 -OH-HCO 3 -CO 3 -CO 2 -H 2 ) System to High Ionic Strength at 25°C

This technical report summarizes model verification results and summary statistics for 41 evaporite mineral solubility cases evaluated by Savannah River National Laboratory using OLI Systems’ aqueous electrolyte thermodynamic modeling software. The 41 verification cases containing a total of 60 solubility curves comprise mineral solubility data from low to high ionic strength at 25°C for the eight-component system Na-K-Mg-Ca-H-Cl-SO 4 -OH-HCO 3 -CO 3 -CO 2 -H 2 O as reported by Harvie et al. (1984). Thermodynamic calculations were executed using OLI Systems’ Stream Analyzer computation module within the OLI Studio software platform (Ver. 11.0, Rev. 11.0.1.9). The Mixed Solvent Electrolyte (MSE) thermodynamic framework was chosen for this investigation because of its superiority in modeling high ionic-strength inorganic salt solutions and actinide redox chemistry and solubility, both of which are relevant to the geological repository conditions at the Waste Isolation Pilot Plant in Carlsbad, New Mexico. Mineral solubility data in various inorganic salt solutions were digitized and extracted from figures generated by Harvie et al. (1984). For each of the 60 solubility curves, a case-specific chemistry model and input file were generated in OLI Studio using OLI Stream Analyzer and the MSE (H 3 O + ion) public databank provided by OLI Systems. Model simulation results were exported to Microsoft Excel to calculate summary statistics and to generate graphs comparing the OLI model predictions to the solubility data. Summary statistics include residuals (model – data) and concordance (accuracy × precision, where precision is indicated by the Pearson correlation coefficient and accuracy accounts for bias and scale differential). Private databanks were not developed, and activity coefficient model regressions were not performed to improve OLI model fits to the data. Of the 41 model verification plots, 83% have a mean of the percent residuals less than or equal to 25%. Similarly, 75% display a concordance greater than or equal to 0.75. Only seven of the 41 verification plots fail to show good agreement between the model and data. Of these seven, three are relevant to the WIPP repository because they involve the Mg-OH-Cl-SO 4 -CO 3 aqueous system. The remaining four address salt solubilities at the pH extremes (strong acid and strong base). It should be noted that in two of the three Mg-OH-Cl-SO 4 -CO 3 system cases, the regressed Harvie et al. (1984) solubility curve also deviated from the data. Lack of agreement between the OLI model-predicted solubility curves and the data is attributable to one or more of the following: specific solid species are not included in the OLI MSE databank; there is significant variation among the different solubility datasets chosen by Harvie et al. (1984); the OLI MSE model’s thermodynamic parameters were determined using different solubility datasets; and the activity coefficient parameters for certain relevant ion-ion and ion-molecule pairs have not been optimized via data regression. Two recommendations for future work are to (1) evaluate solubility data for the Mg-OH-Cl-SO 4 -CO 3 system at high ionic strength and, if necessary, develop a private OLI MSE database that includes missing species and, where necessary, regressed standard state properties and interaction parameters; (2) perform similar verification testing of the OLI model for actinide solubility data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

How Dynamic Time Warping Can Assist Conventional Cross-correlation

Waveform cross-correlation is a sensitive phase-matched filtering technique that can detect seismic events for nuclear explosion monitoring. However, there are outstanding challenges with correlation detectors, most notably a direct dependence on the completeness of the waveform template library. To ameliorate these challenges, we investigate how dynamic time warping (DTW) may make waveform correlation more robust. DTW analyzes the differences between two time series and attempts to “warp” one time series relative to another in a recursive manner. We apply DTW to synthetic earthquake and recorded explosion templates to expand the capability of correlation detectors. We explore what conditions (e.g., source, station distance, frequency bands) and/or DTW algorithms generate stronger correlation scores. We show that DTW performs well on noisy signals and can dramatically improve the cross-correlation coefficient between a template and data-stream waveform. We conclude with recommendations on how to utilize DTW in nuclear monitoring detection.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Pebble Tanker Model for Nuclear Criticality Safety Needs

This report documents a study performed to investigate the requirements for criticality safety benchmark experiments for high-assay, low-enriched uranium (HALEU) fuel in transportation applications. In this work, an exploratory application model, the “Pebble Tanker,” was developed to represent TRISO fuel in a transportation scenario for an analysis of the validation basis in industrial quantities. An aspect of the criticality validation process involves assessing the “similarity” between application and experimental benchmark systems through an integral index parameter evaluation. Here, this includes propagating nuclear data uncertainties and calculating a correlation coefficient (hereinafter referred to as “c k ”) to evaluate the similarity of benchmark experiments compared with the application Pebble Tanker model. Finding sufficient critical benchmark experiments allows for the evaluation of bias and bias uncertainty, thus determining the upper subcritical limit (USL) of the transportation package. A target k eff of ~0.94 was used in this work to establish appropriate modeling conditions, reflecting a reasonable estimate for a USL. Two container models were investigated: one with the Hermes-type pebble and one with the Pebble Bed Modular Reactor (PBMR)–type pebble. The models were simplified, considering only fuel, containment structure, and either water or air. This allows a focus on the underlying physics of applications involving TRISO fuel pebbles using the Pebble Tanker model. A crucial consideration is the transport package's ability to safely hold pebbles while flooded, maintaining subcritical conditions. Tools available in the SCALE 6.3.1 suite—the CSAS6-Shift, TSUNAMI-3D-Shift, and TSUNAMI-IP sequences—were employed for neutronics and sensitivity and uncertainty (S/U) analysis of the Pebble Tanker. Findings demonstrated sufficient available critical experiment benchmarks to perform a validation of the Pebble Tanker in the most reactive state, i.e., when the Tanker is flooded.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation Gap Assessment of a MAP Package Containing Fresh, Metallic Sodium-Cooled Fuel

This report describes an assessment of sodium fast reactor assemblies loaded within an AREVA MAP package. The assessment was performed to determine the state of the validation basis for sodium fast reactor fuel within a transportation package originally intended for fresh, light-water reactor fuel assemblies. A similar study is being simultaneously released (Cumberland, 2025), and substantial parts of the explanatory text are identical to that parallel work, which follows the same workflow. Both studies employed the TSUNAMI-3D and TSUNAMI-IP sequences from the SCALE code system to determine correlation coefficients between various configurations and databases of validation assessments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Validation Gap Assessment of a TN B1 Package Containing Fresh, Metallic Sodium-Cooled Fuel

This report describes an assessment of sodium fast reactor assemblies loaded inside a Transnuclear B1 package. The assessment was performed to determine the state of the validation basis for sodium fast reactor fuel within a transportation package originally intended for fresh, light-water reactor fuel assemblies. The study employed the TSUNAMI-3D and TSUNAMI-IP sequences from the SCALE code system to determine correlation coefficients between various configurations and databases of validation assessments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Comprehensive Docking and MM/GBSA Rescoring Study of Ligand Recognition upon Binding Antithrombin

A high-throughput virtual screening pipeline has been extended from single energetically minimized structure Molecular Mechanics/Generalized Born Surface Area (MM/GBSA) rescoring to ensemble-average MM/GBSA rescoring. The correlation coefficient (R2) of calculated and experimental binding free energies for a series of antithrombin ligands has been improved from 0.36 to 0.69 when switching from the single-structure MM/GBSA rescoring to ensemble-average one. The electrostatic interactions in both solute and solvent are identified to play an important role in determining the binding free energy after the decomposition of the calculated binding free energy. Furthermore, the increasing negative charge of the compounds provides a more favorable electrostatic energy change but creates a higher penalty for the solvation free energy. Such a penalty is compensated by the electrostatic energy change, which results in a better binding affinity. A highly hydrophobic ligand is determined by the docking program to be a non-specific binder. Finally, these results have demonstrated that it is very important to keep a few top poses for rescoring, if the binding is non-specific or the binding mode is not well determined by the docking calculation.

59 BASIC BIOLOGICAL SCIENCES↗

COVID-19–Related School Closures, United States, July 27, 2020–June 30, 2022

As part of a multiyear project that monitored illness-related school closures, we conducted systematic daily online searches during July 27, 2020–June 30, 2022, to identify public announcements of COVID-19–related school closures (COVID-SCs) in the United States lasting ≥1 day. We explored the temporospatial patterns of COVID-SCs and analyzed associations between COVID-SCs and national COVID-19 surveillance data. COVID-SCs reflected national surveillance data: correlation was highest between COVID-SCs and both new PCR test positivity (correlation coefficient [r] = 0.73, 95% CI 0.56–0.84) and new cases (r = 0.72, 95% CI 0.54–0.83) during 2020–21 and with hospitalization rates among all ages (r = 0.81, 95% CI 0.67–0.89) during 2021–22. The numbers of reactive COVID-SCs during 2020–21 and 2021–22 greatly exceeded previously observed numbers of illness-related reactive school closures in the United States, notably being nearly 5-fold greater than reactive closures observed during the 2009 influenza (H1N1) pandemic.

60 APPLIED LIFE SCIENCES↗

Developing predictive models for µ opioid receptor binding using machine learning and deep learning techniques

Opioids exert their analgesic effect by binding to the µ opioid receptor (MOR), which initiates a downstream signaling pathway, eventually inhibiting pain transmission in the spinal cord. However, current opioids are addictive, often leading to overdose contributing to the opioid crisis in the United States. Therefore, understanding the structure-activity relationship between MOR and its ligands is essential for predicting MOR binding of chemicals, which could assist in the development of non-addictive or less-addictive opioid analgesics. This study aimed to develop machine learning and deep learning models for predicting MOR binding activity of chemicals. Chemicals with MOR binding activity data were first curated from public databases and the literature. Molecular descriptors of the curated chemicals were calculated using software Mold2. The chemicals were then split into training and external validation datasets. Random forest, k-nearest neighbors, support vector machine, multi-layer perceptron, and long short-term memory models were developed and evaluated using 5-fold cross-validations and external validations, resulting in Matthews correlation coefficients of 0.528–0.654 and 0.408, respectively. Furthermore, prediction confidence and applicability domain analyses highlighted their importance to the models’ applicability. Our results suggest that the developed models could be useful for identifying MOR binders, potentially aiding in the development of non-addictive or less-addictive drugs targeting MOR.

Research & Experimental Medicine↗

ACCRUE—An Integral Index for Measuring Experimental Relevance in Support of Neutronic Model Validation

A key challenge for the introduction of any design changes, e.g., advanced fuel concepts, first-of-a-kind nuclear reactor designs, etc., is the cost of the associated experiments, which are required by law to validate the use of computer models for the various stages, starting from conceptual design, to deployment, licensing, operation, and safety. To achieve that, a criterion is needed to decide on whether a given experiment, past or planned, is relevant to the application of interest. This allows the analyst to select the best experiments for the given application leading to the highest measures of confidence for the computer model predictions. The state-of-the-art methods rely on the concept of similarity or representativity, which is a linear Gaussian-based inner-product metric measuring the angle—as weighted by a prior model parameters covariance matrix—between two gradients, one representing the application and the other a single validation experiment. This manuscript emphasizes the concept of experimental relevance which extends the basic similarity index to account for the value accrued from past experiments and the associated experimental uncertainties, both currently missing from the extant similarity methods. Accounting for multiple experiments is key to the overall experimental cost reduction by prescreening for redundant information from multiple equally-relevant experiments as measured by the basic similarity index. Accounting for experimental uncertainties is also important as it allows one to select between two different experimental setups, thus providing for a quantitative basis for sensor selection and optimization. The proposed metric is denoted by ACCRUE, short for Accumulative Correlation Coefficient for Relevance of Uncertainties in Experimental validation. Using a number of criticality experiments for highly enriched fast metal systems and low enriched thermal compound systems with accident tolerant fuel concept, the manuscript will compare the performance of the ACCRUE and basic similarity indices for prioritizing the relevance of a group of experiments to the given application.

97 MATHEMATICS AND COMPUTING↗

Establishment of a reverse transcription real-time quantitative PCR method for Getah virus detection and its application for epidemiological investigation in Shandong, China

Getah virus (GETV) is a mosquito-borne, single-stranded, positive-sense RNA virus belonging to the genus Alphavirus of the family Togaviridae . Natural infections of GETV have been identified in a variety of vertebrate species, with pathogenicity mainly in swine, horses, bovines, and foxes. The increasing spectrum of infection and the characteristic causing abortions in pregnant animals pose a serious threat to public health and the livestock economy. Therefore, there is an urgent need to establish a method that can be used for epidemiological investigation in multiple animals. In this study, a real-time reverse transcription fluorescent quantitative PCR (RT-qPCR) method combined with plaque assay was established for GETV with specific primers designed for the highly conserved region of GETV Nsp1 gene. The results showed that after optimizing the condition of RT-qPCR reaction, the minimum detection limit of the assay established in this study was 7.73 PFU/mL, and there was a good linear relationship between viral load and Cq value with a correlation coefficient ( R 2 ) of 0.998. Moreover, the method has good specificity, sensitivity, and repeatability. The established RT-qPCR is 100-fold more sensitive than the conventional RT-PCR. The best cutoff value for the method was determined to be 37.59 by receiver operating characteristic (ROC) curve analysis. The area under the curve (AUC) was 0.956. Meanwhile, we collected 2,847 serum specimens from swine, horses, bovines, sheep, and 17,080 mosquito specimens in Shandong Province in 2022. The positive detection rates by RT-qPCR were 1%, 1%, 0.2%, 0%, and 3%, respectively. In conclusion, the method was used for epidemiological investigation, which has extensive application prospects.

Cao, Xinyu↗

Comparison of venous and pooled capillary hemoglobin levels for the detection of anemia among adolescent girls

Introduction: Blood source is a known preanalytical factor affecting hemoglobin (Hb) concentrations, and there is evidence that capillary and venous blood may yield disparate Hb levels and anemia prevalence. However, data from adolescents are scarce. Objective: To compare Hb and anemia prevalence measured by venous and individual pooled capillary blood among a sample of girls aged 10–19 years from 232 schools in four regions of Ghana in 2022. Methods: Among girls who had venous blood draws, a random subsample was selected for capillary blood. Hb was measured using HemoCue® Hb-301. We used Lin’s concordance correlation coefficient (CCC) to quantify the strength of the bivariate relationship between venous and capillary Hb and a paired t-test for difference in means. We used McNemar’s test for discordance in anemia cases by blood source and weighted Kappa to quantify agreement by anemia severity. A multivariate generalized estimating equation was used to quantify adjusted population anemia prevalence and assess the association between blood source and predicted anemia risk. Results: We found strong concordance between Hb measures (CCC = 0.86). The difference between mean venous Hb (12.8 g/dL, ± 1.1) and capillary Hb (12.9 g/dL, ± 1.2) was not significant (p = 0.26). Crude anemia prevalence by venous and capillary blood was 20.6% and 19.5%, respectively. Adjusted population anemia prevalence was 23.5% for venous blood and 22.5% for capillary ( = 0.45). Blood source was not associated with predicted anemia risk (risk ratio: 0.99, 95% CI: 0.96, 1.02). Discordance in anemia cases by blood source was not significant (McNemar p = 0.46). Weighted Kappa demonstrated moderate agreement by severity (k =0.67). Among those with anemia by either blood source (n = 111), 59% were identified by both sources. Conclusion: In Ghanaian adolescent girls, there was no difference in mean Hb, anemia prevalence, or predicted anemia risk by blood source. However, only 59% of girls with anemia by either blood source were identified as having anemia by both sources. These findings suggest that pooled capillary blood may be useful for estimating Hb and anemia at the population level, but that caution is needed when interpreting individual-level data.

59 BASIC BIOLOGICAL SCIENCES↗