Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth profiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Ion velocity effect governs damage annealing process in defective KTaO 3

Effects of electronic to nuclear energy losses (S e /S n ) ratio on damage evolution in defective KTaO 3 have been investigated by irradiating pre-damaged single crystal KTaO 3 with intermediate energy O ions (6 MeV, 8 MeV and 12 MeV) at 300 K. By exploring these processes in pre-damaged KTaO 3 containing a fractional disorder level of 0.35, the results demonstrate the occurrence of a precursory stage of damage production before the onset of damage annealing process in defective KTaO 3 that decreases with O ion energy. The observed ionization-induced annealing process by ion channeling analysis has been further mirrored by high resolution transmission electron microscopy analysis. In addition, the reduction of disorder level is accompanied by the broadening of the disorder profiles to greater depth with increasing ion fluence, and enhanced migration is observed with decreasing O ion energy. Since S e (~3.0 keV nm –1 ) is nearly constant for all 3 ion energies across the pre-damaged depth, the difference in behavior is due to the so-called 'velocity effect': the lower ion velocity below the Bragg peak yields a confined spread of the electron cascade and hence an increased energy deposition density. Here, the inelastic thermal spike calculation has further confirmed the existence of a velocity effect, not previously reported in KTaO 3 or very scarcely reported in other materials for which the existence of ionization-induced annealing has been reported. In other words, understanding of ionization-induced annealing has been advanced by pointing out that ion velocity effect governs the healing of pre-existing defects, which may have significant implication for the creation of new functionalities in KTaO 3 through atomic-level control of microstructural modifications, but may not be limited to KTaO 3 .

74 ATOMIC AND MOLECULAR PHYSICS↗

Femtosecond X-Ray Diffraction Studies of the Reversal of the Microstructural Effects of Plastic Deformation during Shock Release of Tantalum

Here, we have used femtosecond x-ray diffraction to study laser-shocked fiber-textured polycrystalline tantalum targets as the 37–253 GPa shock waves break out from the free surface. We extract the time and depth-dependent strain profiles within the Ta target as the rarefaction wave travels back into the bulk of the sample. In agreement with molecular dynamics simulations, the lattice rotation and the twins that are formed under shock compression are observed to be almost fully eliminated by the rarefaction process.

36 MATERIALS SCIENCE↗

Design and evaluation of a HDR skin applicator with flattening filter

The purposes of this study are: (i) to design field flattening filters for the Leipzig applicators of 2 and 3 cm of inner diameter with the source traveling parallel to the applicator contact surface, which are accessories of the microSelectron-HDR afterloader (Nucletron, Veenendaal, The Netherlands). These filters, made of tungsten, aim to flatten the heterogeneous dose distribution obtained with the Leipzig applicators. (ii) To estimate the dose rate distributions for these Leipzig+filter applicators by means of the Monte Carlo (MC) method. (iii) To experimentally verify these distributions for prototypes of these new applicators, and (iv) to obtain the correspondence factors to measure the output of the applicators by the user using an insert into a well chamber. The MC GEANT4 code has been used to design the filters and to obtain the dose rate distributions in liquid water for the two Leipzig+filter applicators. In order to validate this specific application and to guarantee that realistic source-applicator geometry has been considered, an experimental verification procedure was implemented in this study, in accordance with the updated recommendations of the American Association of Physicists in Medicine Task Group No. 43 U1 Report. Thermoluminescent dosimeters, radiochromic film, and a pin-point ionization chamber in a plastic [polymethylmethacrylate (PMMA)] phantom were used to verify the MC results for the two applicators of a microSelectron-HDR afterloader with the mHDR-v2 source. To verify the output of the Leipzig+filter applicators, correspondence factors were deduced for the well chambers HDR100-plus (Standard Imaging, Inc., Middleton, WI) and TM33004 (PTW, Freiburg, Germany) using a specific insert for both applicators. The doses measured in the PMMA phantom agree within experimental uncertainties with the dose obtained by the MC calculations. Percentage depth dose and off-axis profiles were obtained normalized at a depth of 3 mm along the central applicator axis in a cylindrical 20x20 cm water phantom. A table of output factors, normalized to 1 U of source air kerma strength at this depth, is presented. Correspondence factors were obtained for the two well chambers considered. The matrix data obtained in the MC simulation with a grid separation of 0.5 mm has been used to build a data set in a convenient format to model these distributions for routine use with a brachytherapy treatment planning system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Initial evaluation of a commercial EPID modified to a novel direct-detection configuration for radiotherapy dosimetry

Electronic portal imaging devices (EPIDs) integrated with medical linear accelerators utilize an indirect-detection EPID configuration (ID-EPID). Amorphous silicon ID-EPIDs provide high quality low dose images for verification of radiotherapy treatments but they have limitations as dosimeters. The standard ID-EPID configuration includes a high atomic number phosphor scintillator screen, a 1 mm copper layer, and other nonwater equivalent materials covering the detector. This configuration leads to marked differences in the response of an ID-EPID compared to standard radiotherapy dosimeters such as ion chambers in water. In this study the phosphor and copper were removed from a standard commercial EPID to modify the configuration to a direct-detection EPID (DD-EPID). Using solid water as the buildup and backscatter for the detector, dosimetric measurements were performed on the DD-EPID and compared to standard dose-in-water data for 6 and 18 MV photons. The sensitivity of the DD-EPID was approximately eight times less than the ID-EPID but the signal was sufficient to produce accurate and reproducible beam profile measurements for open beams and an intensity-modulated beam. Due to the lower signal levels it was found necessary to ensure that the dark field correction (no radiation) DD-EPID signal was stable or updated frequently. The linearity of dose response was comparable to the ID-EPID but with a greater under-response at low doses. DD-EPID measurements of field size output factors and beam profiles at the depth of maximum dose (d{sub max}), and tissue-maximum ratios between the depths of 0.5 and 10 cm, were in close agreement with dose in water measurements. At depths beyond d{sub max} the DD-EPID showed a greater change in response to field size than ionisation chamber measurements and the beam penumbrae were broader compared to diode scans. The modified DD-EPID configuration studied here has the potential to improve the performance of EPIDs for dose verification of radiotherapy treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

The use of a diode matrix in commissioning activities for electron energies {>=}9 MeV: A feasibility study

The contribution of a commercially available diode matrix (MapCHECK trade mark sign , provided by Sun Nuclear, Melbourne, FL) for the commissioning procedures of the voxel based Monte Carlo (VMC++) algorithm for electron beams of MasterPlan treatment planning system was investigated. The attention is mainly focused on the calculation in homogeneous and heterogeneous phantoms. With this aim, following a data set similar to that proposed by Electron Collaborative Working Group (ECWG), the dose profiles and two-dimensional (2D) dose distributions measured by the diode matrix were compared with the calculated ones using the gamma analysis method with acceptance criteria for the dose difference and the distance to agreement equal to 4% and 4 mm, respectively. The average and standard deviation of the percentage of points satisfying the constraint {gamma}{<=}1 are 98.3{+-}4.1% and 99.3{+-}1.7% for the 9 and 12 MeV electron beam, respectively, showing that the accuracy of MasterPlan electron beam algorithm is good for simple two-dimensional geometries as well as for more complicated three-dimensional ones. The results are in agreement with those reported in literature by Cygler et al. [''Evaluation of the first commercial Monte Carlo dose calculation engine for electron beam treatment planning,'' Med. Phys. 31, 142-153 (2004)]. In addition, the authors have also analyzed the response of the 2D array in terms of dose profiles at different depths, comparing the results with those obtained in water phantom using an electron diode. The results show that in the low gradient regions there were no deviations larger than the criteria of acceptability set by Van Dyk et al. [''Commissioning and quality assurance of treatment planning computers,'' Int. J. Radiat. Oncol. Biol. Phys. 26, 261-273 (1993)]; in the high gradient region, the maximum deviations are less than 2 mm with most of the values less than 1 mm. The present article shows that MapCHECK trade mark sign can play a useful role in the commissioning of electron algorithms of treatment planning systems in the evaluation of the 2D dose distributions in homogeneous and heterogeneous phantoms. In fact, it provides accurate results with the merit of expediting the commissioning process by using measuring device that requires minimal setup time and data processing time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of a novel phase-space-based cylindrical dose kernel for IMRT optimization

Purpose: Improving dose calculation accuracy is crucial in intensity-modulated radiation therapy (IMRT). We have developed a method for generating a phase-space-based dose kernel for IMRT planning of lung cancer patients. Methods: Particle transport in the linear accelerator treatment head of a 21EX, 6 MV photon beam (Varian Medical Systems, Palo Alto, CA) was simulated using the EGSnrc/BEAMnrc code system. The phase space information was recorded under the secondary jaws. Each particle in the phase space file was associated with a beamlet whose index was calculated and saved in the particle's LATCH variable. The DOSXYZnrc code was modified to accumulate the energy deposited by each particle based on its beamlet index. Furthermore, the central axis of each beamlet was calculated from the orientation of all the particles in this beamlet. A cylinder was then defined around the central axis so that only the energy deposited within the cylinder was counted. A look-up table was established for each cylinder during the tallying process. The efficiency and accuracy of the cylindrical beamlet energy deposition approach was evaluated using a treatment plan developed on a simulated lung phantom. Results: Profile and percentage depth doses computed in a water phantom for an open, square field size were within 1.5% of measurements. Dose optimized with the cylindrical dose kernel was found to be within 0.6% of that computed with the nontruncated 3D kernel. The cylindrical truncation reduced optimization time by approximately 80%. Conclusions: A method for generating a phase-space-based dose kernel, using a truncated cylinder for scoring dose, in beamlet-based optimization of lung treatment planning was developed and found to be in good agreement with the standard, nontruncated scoring approach. Compared to previous techniques, our method significantly reduces computational time and memory requirements, which may be useful for Monte-Carlo-based 4D IMRT or IMAT treatment planning.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-51: Dose Response of Common Solid State Detectors in Homogeneous Transverse and Longitudinal Magnetic Fields

Purpose: Solid state radiation detectors are often used for dose profiles and percent depth dose measurements. The dose response of selected solid state detectors is evaluated in varying transverse and longitudinal magnetic fields for eventual use in MR-Linac devices. Methods: A PTW 60003 and IBA PFD detector were modeled in the Monte Carlo code PENELOPE, incorporating a magnetic field which was varied in strength and oriented both transversely and longitudinally with respect to the incident photon beam. The detectors' long axis was in turn oriented either parallel or perpendicular to the photon beam. Dose to the active volume of each detector was scored, and its ratio to dose with zero magnetic field strength (dose response) was determined. Accuracy of the simulations was evaluated by measurements using both chambers taken at low field with a small electromagnet. Simulations were also performed in a water phantom to compare to the in air results. Results: Significant dose response was found in transverse field geometries, nearing 20% at 1.5T. The response is highly dependent on relative orientations to the magnetic field and photon beam, and on detector composition. Low field measurements confirm these results. In the presence of longitudinal magnetic fields, the detectors exhibit little dose response, reaching 0.5–1% at 1.5T regardless of detector orientation. Water tank simulations compared well to the in air simulations when not at the beam periphery, where in transverse magnetic fields only, the water tank simulations differed from the in air results. Conclusion: Transverse magnetic fields can cause large deviations in dose response, and are highly position orientation dependent. Comparatively, longitudinal magnetic fields exhibit little to no dose response in each detector as a function of magnetic field strength. Water tank simulations show longitudinal fields are generally easier to work with, but each detector must be evaluated separately.

07 ISOTOPE AND RADIATION SOURCES↗

TU-F-CAMPUS-T-04: An Evaluation of Out-Of-Field Doses for Electron Beams From Modern Varian and Elekta Linear Accelerators

Purpose: Accurately determining out-of-field doses when using electron beam radiotherapy is of importance when treating pregnant patients or patients with implanted electronic devices. Scattered doses outside of the applicator field in electron beams have not been broadly investigated, especially since manufacturers have taken different approaches in applicator designs. Methods: In this study, doses outside of the applicator field were measured for electron beams produced by a 10×10 applicator on two Varian 21iXs operating at 6, 9, 12, 16, and 20 MeV, a Varian TrueBeam operating at 6, 9, 12, 16, and 20 MeV, and an Elekta Versa HD operating at 6, 9, 12 and 15 MeV. Peripheral dose profiles and percent depth doses were measured in a Wellhofer water phantom at 100 cm SSD with a Farmer ion chamber. Doses were compared to peripheral photon doses from AAPM’s Task Group #36 report. Results: Doses were highest for the highest electron energies. Doses typically decreased with increasing distance from the field edge but showed substantial increases over some distance ranges. Substantial dose differences were observed between different accelerators; the Elekta accelerator had much higher doses than any Varian unit examined. Surprisingly, doses were often similar to, and could be much higher than, doses from photon therapy. Doses decreased sharply with depth before becoming nearly constant; the dose was found to decrease to a depth of approximately E(MeV)/4 in cm. Conclusion: The results of this study indicate that proper shielding may be very important when utilizing electron beams, particularly on a Versa HD, while treating pregnant patients or those with implanted electronic devices. Applying a water equivalent bolus of Emax(MeV)/4 thickness (cm) on the patient would reduce fetal dose drastically for all clinical energies and is a practical solution to manage the potentially high peripheral doses seen from modern electron beams. Funding from NIH Grant number: #CA180803.

60 APPLIED LIFE SCIENCES↗

CO2 and CH4 leaf-level fluxes and soil porewater concentrations from common vegetation patches in Louisiana’s coastal wetlands

This dataset contains leaf-level flux and soil porewater concentration measurements of carbon dioxide (CO2) and methane (CH4 ) in plots in the footprint of Ameriflux sites US-LA2 and US-LA3. Leaf fluxes in US-LA2 were measured on patches dominated by Sagittaria lancifolia and co-dominated by Sagittaria lancifolia and Typha latifolia. In US-LA3, fluxes were measured from distinct Juncus roemerianus and Spartina alterniflora patches. The porewater concentrations were collected across a vertical profile (~50 cm depth) at centric locations within 25 m2 plots where we measured the leaf fluxes. US-LA3 included an additional set of measurements in open water spots. We aimed to evaluate differences in leaf fluxes and porewater pools of CO2 and CH4 of representative ecohydrological patches across a salinity gradient. We also used this dataset to help develop ELM-Wet, a more realistic representation of wetland carbon biogeochemical processes within the U.S. Department of Energy’s Energy Exascale Earth System Model (E3SM) Land Model version 1 (ELM v.1). The files can be opened with regular text editors or spreadsheet programs. Version 2.0 (8/26/2025): This is the latest version of this dataset. The update includes additional samples of soil porewater CH4/CO2 concentrations from June-2021 to November-2022, as well as minor adjustments made to V1 samples via changing Henry's solubility to account for porewater salinity. Additionally leaf-level measurments of spectral indices, PSRI, NDVI, and PRI have been added to complement Leaf-level flux measurements. All V1 data sets have been integrated into V2 sheets, ensuring data from the previous version is contained with the additional samples and consistent with V2 metadata.

54 ENVIRONMENTAL SCIENCES↗

Effects of 9.5 Years of Whole-Soil Warming on the Fatty Acid and n-Alkanes Composition in Bulk Soil and Density Fractions at Blodgett Experimental Forest, California, USA

Original data of molecular data (fatty acids and n-alkanes) including concentrations and calculated molecular proxies in a whole-soil warming experiment at the Blodgett Forest Research Station after 9.5 years of warming. The study site has a Mediterranean climate with annual average temperature of 12.5 ℃ and annual average precipitation of 1774 mm. The study site is characterized by a mesic Ultic Alfisol formed from granitic parent material, corresponding to a Dystric Cambisol under the World Reference Base for Soil Resources (WRB) classification system. Experimental warming is applied throughout the soil profile to a depth of 1 m using vertically embedded heating cables that raise soil temperature by 4 °C relative to ambient conditions. Soil samples were collected on 1 May 2023, after the experiment had been operating continuously for about 9.5 years since its initiation in January 2014.The data has been processed from raw data and cross-validated by other peers. The dataset includes: - Bulk_Fattyacid_9.5-year_Soil_Warming_Blodgett, California, USA: fatty acid concentrations and proxies including Carbon Preference Index (CPI) and Average Chain Length (ACL) of bulk soil organic carbon; - Fractions_Fattyacid_9.5-year_Soil_Warming_Blodgett, California, USA: fatty acid concentrations and proxies including CPI and ACL of free particulate organic matter (fPOM) and mineral-associated organic matter (MAOM); - Bulk_Alkanes_9.5-year_Soil_Warming_Blodgett, California, USA: n-alkanes concentrations and proxies including CPI and ACL of bulk soil organic carbon; - Fractions_Alkanes_9.5-year_Soil_Warming_Blodgett, California, USA: n-alkanes concentrations and proxies including CPI and ACL of fPOM and MAOM; - n-Alkanes_All_Monomer_Concentration_9.5-year_Soil_Warming_Blodgett, California, USA: concentration of all the n-alkane monomers identified and integrated for bulk soil, fPOM and MAOM; - Fattyacid_All_Monomer_Concentration_9.5-year_Soil_Warming_Blodgett, California, USA: concentration of all the fatty acid monomers including diacids identified and integrated for bulk soil, fPOM, and MAOM. All data are provided in CSV format and can be viewed using Microsoft Excel. We specifically look at fatty acids (FA) and n-alkanes in bulk soil, fPOM and MAOM and calculated molecular proxies such as CPI and ACL to understand the source of oragnic carbon (with ACL) and degree of decomposition (CPI) of each soil fraction. Due to lack of long-chain fatty acids (carbon number ⩾ 20), microorganism-derived organic carbon is characterized by shorter ACL in comparison to plant-derived organic carbon. Fresh SOC is characterized by even-over-odd dominance for fatty acids and odd-over-even dominance for n-alkanes. Therefore, CPI indicates whether soil organic carbon (SOC) represents fresh input (CPI > 10) or is strongly decomposed (close to 1). The research questions should be then, after 9.5-year warming: 1. whether the relative contribution between microorganism-derived and plant-derived SOC in each soil fraction? 2. whether fPOM became more decomposed whereas MAOM remained relatively persistent in each soil fraction across the soil depth?

Carbon↗

Experimental Studies and Model Analysis of Noble Gas Fractionation in Porous Media

Core Ideas Ambient noble gases in porous media fractionate from through‐flow of other gases. CO 2 fluxes and noble‐gas fractionation are measured in simple sandbox experiments. Modeled fractionation provides indirect proxy, e.g., of steady CO 2 leakage fluxes. The noble gases, which are chemically inert under normal terrestrial conditions but vary systematically across a wide range of atomic mass and diffusivity, offer a multicomponent approach to investigating gas dynamics in unsaturated soil horizons, including transfer of gas between saturated zones, unsaturated zones, and the atmosphere. To evaluate the degree to which fractionation of noble gases in the presence of an advective–diffusive flux agrees with existing theory, a simple laboratory sand column experiment was conducted. Pure CO 2 was injected at the base of the column, providing a series of constant CO 2 fluxes through the column. At five fixed sampling depths within the system, samples were collected for CO 2 and noble gas analyses, and ambient pressures were measured. Both the advection–diffusion and dusty gas models were used to simulate the behavior of CO 2 and noble gases under the experimental conditions, and the simulations were compared with the measured depth‐dependent concentration profiles of the gases. Given the relatively high permeability of the sand column (5 × 10 −11 m 2 ), Knudsen diffusion terms were small, and both the dusty gas model and the advection–diffusion model accurately predicted the concentration profiles of the CO 2 and atmospheric noble gases across a range of CO 2 flux from ∼700 to 10,000 g m −2 d −1 . The agreement between predicted and measured gas concentrations demonstrated that, when applied to natural systems, the multi‐component capability provided by the noble gases can be exploited to constrain component and total gas fluxes of non‐conserved (CO 2 ) and conserved (noble gas) species or attributes of the soil column relevant to gas transport, such as porosity, tortuosity, and gas saturation.

54 ENVIRONMENTAL SCIENCES↗

Cavity length dependence of mode beating in passively Q-switched Nd-solid state lasers

The beat frequencies, temporal intensity profile, and modulation depth of a flash lamp pumped passively Q-switched, Nd:Cr:GSGG monoblock laser with a Cr +4 :YAG Q switch are investigated as a function of cavity length. The measured temporal widths are linearly correlated with cavity length and the modulation depths of the temporal waveforms are periodic in nature with cavity length, peaking at integer multiples of c/2nL. Simulations support measured trends in the pulse widths and beat frequencies as a function of cavity length.

Zameroski, Nathan D.↗

Using AMIE data to study cloud processes within the Madden-Julian Oscillation

This study uses AMIE data to show how the small clouds in the Madden-Julian Oscillation first organize into lines and other patterns, how they develop the first rainshowers, how those showers deposit cool air over the ocean surface, how this cool air spreads and triggers deeper convection, how the deep convection develops into mesoscale systems, how the mesoscale systems modify the heating profile through the depth of the troposphere, and how the development of the clouds responds to and interacts with large-scale waves circumnavigating the globe at upper levels, and how equatorial trapped waves at lower levels modulates the development of the cloud population. The techniques used to analyze the radar and sounding data collected in AMIE to achieve the above results are innovative, and to obtain more general results we have used regional modeling with a variety of cloud microphysical schemes in combination with the data analyses.

58 GEOSCIENCES↗

Understanding Mechanistic Controls of Heterotrophic CO 2 and CH 4 Fluxes in a Peatland with Deep Soil Warming and Atmospheric CO 2 Enrichment

This project was funded from August 1, 2016 – July 31, 2019 with a no-cost extension until July 31, 2020 (and built upon the PI-team’s previous work supported by DE-SC0008092 (June 2012 – September 2016)). Our project focused on the Spruce and Peatland Responses Under Changing Environments (SPRUCE: https://mnspruce.ornl.gov/) experiment taking place in the S1 Bog in the Marcell Experimental Forest in northern Minnesota, USA. The SPRUCE project is a unique whole-ecosystem experiment where a bog peatland is subjected to warming and atmospheric carbon dioxide (CO 2 ) enrichment. Deep peat heating of the soil profile (to a depth of at least 2 m) began in June of 2014 and was followed by whole-ecosystem warming in August of 2015. Warming treatments included +0 °C, +2.25 °C, +4.5 °C, +6.75 °C, and +9 °C above ambient temperatures, with 2 experimental chambers for each warming treatment. Half of these chambers received ambient atmospheric CO 2 concentrations, and starting in June of 2016, the other half received elevated atmospheric CO 2 concentrations (~ +500 ppm(v) above ambient). Our primary goal with this project was to explore the mechanistic controls of anaerobic carbon cycling – especially the dynamics of the potent greenhouse gas methane (CH 4 ) – within the SPRUCE experiment.

54 ENVIRONMENTAL SCIENCES↗

Subsurface Temperature, Moisture, Thermal Conductivity and Heat Flux, Area A, B, C, and D, Utqiagvik (Barrow), Alaska, Ongoing from 2012

Subsurface soil monitoring stations are located across each of the four NGEE Arctic, Utqiagvik (Barrow), Alaska, intensive study Areas: (A) low-centered polygons with well-defined troughs, (B) high-centered polygons, (C) flat-centered or transitional polygons, and (D) inundated low-centered polygons with no troughs. Two data products are being generated - both with high temporal (hourly) and spatial resolution (within polygon and with depth): (1) soil profile temperature measurements and (2) active layer and permafrost temperature and moisture measurements from instrumented soil pits. This data package currently contains seventy-nine .csv files, one .xlsx (with complimentary .csv file), and one .pdf. Data from September 2012 through August 2022 are available as annual files. Additional data will be added annually after quality checks have been completed. These data are being collected to better understand the thermal dynamics of the active layer and permafrost. Together this information serves as calibration and evaluation data for fine-scale simulations of polygons. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

The multi-scattering model for calculations of positron spatial distribution in the multilayer stacks, useful for conventional positron measurements

The spatial distribution of positrons emitted from radioactive isotopes into stacks or layered samples is a subject of the presented report. It was found that Monte Carlo (MC) simulations using GEANT4 code are not able to describe correctly the experimental data of the positron fractions in stacks. The mathematical model was proposed for calculations of the implantation profile or positron fractions in separated layers or foils being components of a stack. The model takes into account only two processes, i.e., the positron absorption and backscattering at interfaces. The mathematical formulas were applied in the computer program called LYS-1 (layers profile analysis). The theoretical predictions of the model were in the good agreement with the results of the MC simulations for the semi infinite sample. The experimental verifications of the model were performed on the symmetrical and non-symmetrical stacks of different foils. The good agreement between the experimental and calculated fractions of positrons in components of a stack was achieved. Also the experimental implantation profile obtained using the depth scanning of positron implantation technique is very well described by the theoretical profile obtained within the proposed model. The LYS-1 program allows us also to calculate the fraction of positrons which annihilate in the source, which can be useful in the positron spectroscopy.

97 MATHEMATICS AND COMPUTING↗

Evaluation of clinical IMRT treatment planning using the GATE Monte Carlo simulation platform for absolute and relative dose calculations

Purpose: The objective of this study was to evaluate and validate the use of the Geant4 application for emission tomography (GATE) Monte Carlo simulation platform for clinical intensity modulated radiotherapy (IMRT) dosimetry studies. Methods: The first step consisted of modeling a 6 MV photon beam linear accelerator (LINAC), with its corresponding validation carried out using percent depth dose evaluation, transverse profiles, tissue phantom ratio, and output factor on water phantom. The IMRT evaluation was performed by comparing simulation and measurements in terms of absolute and relative doses using IMRT dedicated quality assurance phantoms considering seven different patient datasets. Results: Concerning the LINAC simulated model validation tissue phantom ratios at 20 and 10 cm in water TPR{sub 10}{sup 20} obtained from GATE and measurements were 0.672 {+-} 0.063 and 0.675, respectively. In terms of percent depth dose and transverse profiles, error ranges were, respectively: 1.472%{+-} 0.285% and 4.827%{+-} 1.323% for field size of 4 Multiplication-Sign 4, 5 Multiplication-Sign 5, 10 Multiplication-Sign 10, 15 Multiplication-Sign 15, 20 Multiplication-Sign 20, 25 Multiplication-Sign 25, 30 Multiplication-Sign 30, and 40 Multiplication-Sign 40 cm{sup 2}. Most errors were observed at the edge of radiation fields because of higher dose gradient in these areas. Output factors showed good agreement between simulation and measurements with a maximum error of 1.22%. Finally, for IMRT simulations considering seven patient datasets, GATE provided good results with a relative error of 0.43%{+-} 0.25% on absolute dose between simulated and measured beams (measurements at the isocenter, volume 0.125 cm{sup 3}). Planar dose comparisons were also performed using gamma-index analysis. For the whole set of beams considered the mean gamma-index value was 0.497 {+-} 0.152 and 90.8%{+-} 3.6% of the evaluated dose points satisfied the 5%/ 4 mm criterion. Conclusions: These results show that GATE allows reliable simulation of complex beams in radiotherapy after an accurate LINAC modeling is validated. A simple cross-calibration procedure proposed in this work allows obtaining absolute dose values even in complex fields.

60 APPLIED LIFE SCIENCES↗

Poster - 20: Detector selection for commissioning of a Monte Carlo based electron dose calculation algorithm

Objective: Commissioning of a Monte Carlo based electron dose calculation algorithm requires percentage depth doses (PDDs) and beam profiles which can be measured with multiple detectors. Electron dosimetry is commonly performed with cylindrical chambers but parallel plate chambers and diodes can also be used. The purpose of this study was to determine the most appropriate detector to perform the commissioning measurements. Methods: PDDs and beam profiles were measured for beams with energies ranging from 6 MeV to 15 MeV and field sizes ranging from 6 cm × 6 cm to 40 cm × 40 cm. Detectors used included diodes, cylindrical and parallel plate ionization chambers. Beam profiles were measured in water (100 cm source to surface distance) and in air (95 cm source to detector distance). Results: PDDs for the cylindrical chambers were shallower (1.3 mm averaged over all energies and field sizes) than those measured with the parallel plate chambers and diodes. Surface doses measured with the diode and cylindrical chamber were on average larger by 1.6 % and 3% respectively than those of the parallel plate chamber. Profiles measured with a diode resulted in penumbra values smaller than those measured with the cylindrical chamber by 2 mm. Conclusion: The diode was selected as the most appropriate detector since PDDs agreed with those measured with parallel plate chambers (typically recommended for low energies) and results in sharper profiles. Unlike ion chambers, no corrections are needed to measure PDDs, making it more convenient to use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗