At least 1,063 records · Page 59

Enriched Boron-Doped Amorphous Selenium Based Position-Sensitive Solid-State Thermal Neutron Detector for MPACT Applications

High-efficiency thermal neutron detectors with compact size, low power-rating and high spatial, temporal and energy resolution are essential to execute non-proliferation and safeguard protocols. The demands of such detector are not fully covered by the current detection system such as gas proportional counters or scintillator-photomultiplier tube combinations, which are limited by their detection efficiency, stability of response, speed of operation, and physical size. Furthermore, world-wide shortage of 3 He gas, required for widely used gas detection method, has further prompted to design an alternative system. Therefore, a solid-state neutron detection system without the requirement of 3 He will be very desirable. To address the above technology gap, we had proposed to develop new room temperature solidstate thermal neutron detectors based on enriched boron ( 10 B) and enriched lithium ( 6 Li) doped amorphous Se (As- 0.52%, Cl 5 ppm) semiconductor for MPACT applications. The proposed alloy materials have been identified for its many favorable characteristics - a wide bandgap (~2.2 eV at 300 K) for room temperature operation, high glass transition temperature (t g ~ 85°C), a high thermal neutron cross-section (for boron ~ 3840 barns, for lithium ~ 940 barns, 1 barn = 10 -24 cm 2 ), low effective atomic number of Se for small gamma ray sensitivity, and high radiation tolerance due to its amorphous structure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SATS Transient Fission Gas Release Test with Irradiated Fuel under Loss of Coolant Accident Conditions

The transient fission gas release (tFGR) during the temperature ramp associated with a loss-of-coolant accident (LOCA) in light-water reactors (LWRs) is likely a significant contribution to the total pressure in a fuel rod and may cause an unexpected rod burst. The lack of data related to tFGR continues to be a key gap in understanding LWR cladding burst behavior under LOCA conditions. To fully characterize this behavior, tFGR data must be collected from several different systems that can capture all relevant testing conditions. Oak Ridge National Laboratory (ORNL) has developed a system to measure the integral tFGR from irradiated fuel segments. This system was designed to integrate with the existing Severe Accident Test Station (SATS) and to build upon decades of experience capturing fission gas to characterize fuel behavior. The tFGR system consists of a sweep gas system to transport gases from the in-cell SATS apparatus to an out-of-cell fission gas detection system composed of a series of cold traps to capture the off-gas from the heating tests and a gamma spectrometry system to detect and measure 85 Kr. Initial system testing operations were completed during which 85 Kr collection and measurement were verified along with the ability to detect stable inert gases. A tFGR test with a high-burnup fuel specimen was successfully conducted by the in-cell SATS-tFGR system at ORNL. The posttest examination is under way, the result of which will be reported in FY24.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Real-time Intrusion Detection for High-bandwidth Research Networks using Unsupervised Deep Learning

Nowadays, data generated by large-scale scientific experiments are on the scale of petabytes per month. These data are transferred through dedicated high-bandwidth networks across distributed collaboration sites for processing, storage, and analysis. Like general purpose networks, research networks experience attacks. However, monitoring traffic in such high-bandwidth network environments is challenging with conventional deep packet inspection (DPI)- based network intrusion detection systems (NIDS). Recently, machine learning (ML) algorithms have shown potential in detecting anomalous patterns with better generalizability and faster speed. Compared to the general purpose networks, traffic movement in research network is less volatile and more likely to benefit from the ML-based anomaly analysis. We present ThunderSecure, an efficient AI-powered system for detecting anomalies in 100G research networks. ThunderSecure implements a high-throughput packet processing infrastructure using multi-cores and GPUs. It takes time-series statistics from a variety of network measurements and uses 2D Convolutional Neural Network (CNN) to explore both spatial and temporal dependencies in network data stream. Patterns of science data traffic are learned with a one-class neural network, which blends an Adversarial Autoencoder (AAE) with Gaussian mixture density estimation. Testing traffic flows exhibiting significant deviations from the learned baseline of normality are marked as anomalies. We trained ThunderSecure on hundreds of billions of science data packets recorded from a 100G research network at Fermi National Accelerator Laboratory. The detection performance was evaluated on traffic captured from the same research network days and weeks after the training with different types of attack flows injected. To the best of our knowledge, this is the first ML work in the area of network anomaly detection that has been validated on such extreme scale datasets. Results show that ThunderSecure can recognize science data traffic that are captured long after the training and make nearly certain detection on those with anomalous flows injected, even in the case when the anomaly-to-normal mixing ratio is 0.1%.

Gong, Qian↗

False Data Injection and Detection in LQG Systems: A Game Theoretic Approach

Cyber-physical systems are vulnerable to false data injection by adversaries who compromise cyber communication links. In this paper, an infinite horizon linear quadratic Gaussian (LQG) system is considered wherein the control inputs transmitted over cyber links are vulnerable to compromise and false data injection by adversaries. The adversarial cyber-attack is driven to minimize the performance of the LQG system, and the controller is equipped with an intrusion detection system that monitors the sequence of internal physical states to detect adversarial input modification. The problem is formulated as a two-player zero-sum game with the false alarm probability as the reward, wherein the attacker aims to achieve a target increase in controller cost while maximizing the false alarm probability, and a detector who wishes to minimize the false alarm probability while remaining consistent. It is shown that in such a game, an ε-equilibrium exists. The equilibrium attacker strategy is the one that minimizes the Kullback-Leibler distance between legitimate and falsified state dynamics, and the equilibrium detector strategy is the corresponding likelihood-ratio test. Numerical simulations are presented that showcase the equilibrium strategy pair and the intuitive strategies comparisons.

97 MATHEMATICS AND COMPUTING↗

Networked Gamma Radiation System for Tactical Deployment

A networked gamma radiation detection system with directional sensitivity and energy spectral data acquisition capability is being developed by the National Security Technologies, LLC, Remote Sensing Laboratory to support the close and intense tactical engagement of law enforcement who carry out counterterrorism missions. In the proposed design, three clusters of 2" × 4" × 16" sodium iodide crystals (4 each) with digiBASE-E (for list mode data collection) would be placed on the passenger side of a minivan. To enhance localization and facilitate rapid identification of isotopes, advanced smart real-time localization and radioisotope identification algorithms like WAVRAD (wavelet-assisted variance reduction for anomaly detection) and NSCRAD (nuisance-rejection spectral comparison ratio anomaly detection) will be incorporated. We will test a collection of algorithms and analysis that centers on the problem of radiation detection with a distributed sensor network. We will study the basic characteristics of a radiation sensor network and focus on the trade-offs between false positive alarm rates, true positive alarm rates, and time to detect multiple radiation sources in a large area. Empirical and simulation analyses of critical system parameters, such as number of sensors, sensor placement, and sensor response functions, will be examined. This networked system will provide an integrated radiation detection architecture and framework with (i) a large nationally recognized search database equivalent that would help generate a common operational picture in a major radiological crisis; (ii) a robust reach back connectivity for search data to be evaluated by home teams; and, finally, (iii) a possibility of integrating search data from multi-agency responders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high accuracy femto-/picosecond laser damage test facility dedicated to the study of optical thin films

A laser damage test facility delivering pulses from 100 fs to 3 ps and designed to operate at 1030 nm is presented. The different details of its implementation and performances are given. The originality of this system relies the online damage detection system based on Nomarski microscopy and the use of a non-conventional energy detection method based on the utilization of a cooled CCD that offers the possibility to obtain the laser induced damage threshold (LIDT) with high accuracy. Applications of this instrument to study thin films under laser irradiation are presented. Particularly the deterministic behavior of the sub-picosecond damage is investigated in the case of fused silica and oxide films. It is demonstrated that the transition of 0-1 damage probability is very sharp and the LIDT is perfectly deterministic at few hundreds of femtoseconds. The damage process in dielectric materials being the results of electronic processes, specific information such as the material bandgap is needed for the interpretation of results and applications of scaling laws. A review of the different approaches for the estimation of the absorption gap of optical dielectric coatings is conducted and the results given by the different methods are compared and discussed. The LIDT and gap of several oxide materials are then measured with the presented instrument: Al{sub 2}O{sub 3}, Nb{sub 2}O{sub 5}, HfO{sub 2}, SiO{sub 2}, Ta{sub 2}O{sub 5}, and ZrO{sub 2}. The obtained relation between the LIDT and gap at 1030 nm confirms the linear evolution of the threshold with the bandgap that exists at 800 nm, and our work expands the number of tested materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mobile Pit verification system design based on passive special nuclear material verification in weapons storage facilities

A mobile 'drive by' passive radiation detection system to be applied in special nuclear materials (SNM) storage facilities for validation and compliance purposes has been designed through the use of computational modeling and new radiation detection methods. This project was the result of work over a 1 year period to create optimal design specifications to include creation of 3D models using both Monte Carlo and deterministic codes to characterize the gamma and neutron leakage out each surface of SNM-bearing canisters. Results were compared and agreement was demonstrated between both models. Container leakages were then used to determine the expected reaction rates using transport theory in the detectors when placed at varying distances from the can. A 'typical' background signature was incorporated to determine the minimum signatures versus the probability of detection to evaluate moving source protocols with collimation. This established the criteria for verification of source presence and time gating at a given vehicle speed. New methods for the passive detection of SNM were employed and shown to give reliable identification of age and material for highly enriched uranium (HEU) and weapons grade plutonium (WGPu). The finalized 'Mobile Pit Verification System' (MPVS) design demonstrated that a 'drive-by' detection system, collimated and operating at nominally 2 mph, is capable of rapidly verifying each and every weapon pit stored in regularly spaced, shelved storage containers, using completely passive gamma and neutron signatures for HEU and WGPu. This system is ready for real evaluation to demonstrate passive total material accountability in storage facilities. (authors)

97 MATHEMATICS AND COMPUTING↗

Optimizing Ventilation Using Low-Cost Sensors to Improve Health, Safety, and Energy Efficiency

Air is the primary carrier of hazards within a space, whether it be hazardous bi-products of research activities or airborne pathogens. As a result, building ventilation is the primary defense against unseen airborne hazards. Critical laboratory facilities already demand the need for effective mitigation of exposure to research-related, airborne hazards, providing a proving ground for effective ventilation strategies that optimize safety of occupants and reduce energy use. The heart of smart laboratory building operation is dynamic, analytics-based ventilation, which requires an intimate knowledge of building environmental conditions achieved through contaminant-detection systems. Unfortunately, currently available contaminant-detection solutions are expensive, elaborate systems that raise barriers for building managers on a limited budget. Through the successful deployment of a novel low-cost, modular sensor technology, we have developed a demand-control ventilation protocol effective in improving safety and reducing energy in the critical laboratory environment. In this session, we will highlight best practices and lessons learned through this deployment that can be applied beyond laboratories without breaking the bank. This paper describes a low-cost solution for providing a safe, healthy building environment and reducing energy use through effective, efficient ventilation.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Optimizing Ventilation Using Low-Cost Sensors to Improve Health, Safety, and Energy Efficiency

Air is the primary carrier of hazards within a space, whether it be hazardous byproducts of laboratory research activities or airborne pathogens. As a result, building ventilation is a primary defense against unseen airborne hazards. Critical laboratory facilities require effective mitigation of exposure to research-related, airborne hazards, providing a proving ground for effective ventilation strategies that optimize safety of occupants and reduce energy use. The heart of smart laboratory building operation is dynamic, analytics-based ventilation, which requires an in-depth intimate knowledge of building environmental conditions achieved through contaminant-detection systems. Unfortunately, currently many contaminant-detection solutions are expensive, elaborate systems that raise barriers for building managers. Through the successful deployment of a novel low-cost, modular sensor technology, we have developed a demand-control ventilation protocol effective in improving safety and reducing energy in critical laboratory environments. In this article, we will highlight best practices and lessons learned through this deployment that can be applied beyond laboratories. This article describes a low-cost sensor to support providing a safe, healthy building environment and reduce energy use through effective and efficient ventilation.

dynamic management of indoor air quality↗

Development of a Real-Time Neutron Noise Analysis System for Fuel Debris Removal at Fukushima Daiichi

The decommissioning of Units 1, 2, and 3 at Fukushima Daiichi presents unique challenges, particularly in mitigating the risk of re-criticality during fuel debris removal. Disturbing previously stable debris configurations has the potential to cause changes in the multiplication of the system, necessitating real-time monitoring to ensure operational safety. Current neutron detection systems, primarily passive, are not optimized for continuous real-time analysis and are limited in their ability to detect rapid changes in system reactivity.

Neutron Detection Systems↗

Buried object detection in GPR images

A method and system for detecting the presence of subsurface objects within a medium is provided. In some embodiments, the imaging and detection system operates in a multistatic mode to collect radar return signals generated by an array of transceiver antenna pairs that is positioned across the surface and that travels down the surface. The imaging and detection system pre-processes the return signal to suppress certain undesirable effects. The imaging and detection system then generates synthetic aperture radar images from real aperture radar images generated from the pre-processed return signal. The imaging and detection system then post-processes the synthetic aperture radar images to improve detection of subsurface objects. The imaging and detection system identifies peaks in the energy levels of the post-processed image frame, which indicates the presence of a subsurface object.

97 MATHEMATICS AND COMPUTING↗

Real-Time Model-Based Leak-Through Detection within Cryogenic Flow Systems

The timely detection of leaks within cryogenic fuel replenishment systems is of significant importance to operators on account of the safety and economic impacts associated with material loss and operational inefficiencies. Associated loss in control of pressure also effects the stability and ability to control the phase of cryogenic fluids during replenishment operations. Current research dedicated to providing Prognostics and Health Management (PHM) coverage of such cryogenic replenishment systems has focused on the detection of leaks to atmosphere involving relatively simple model-based diagnostic approaches that, while effective, are unable to isolate the fault to specific piping system components. The authors have extended this research to focus on the detection of leaks through closed valves that are intended to isolate sections of the piping system from the flow and pressurization of cryogenic fluids. The described approach employs model-based detection of leak-through conditions based on correlations of pressure changes across isolation valves and attempts to isolate the faults to specific valves. Implementation of this capability is enabled by knowledge and information embedded in the domain model of the system. The approach has been used effectively to detect such leak-through faults during cryogenic operational testing at the Cryogenic Testbed at NASA's Kennedy Space Center.

Walker, M.↗

Detection of Gas Slugs in Heat Pipes

Temperature sensing system detects presence of gas slugs in heat pipes. System designed for operation between zero and 70 degrees C and detects noncondensable pockets of gas that result from decomposition of ammonia cooling fluid. Slugs 1 in. (25mm) in length detected.

Jones, J. A.↗

Fire Detection Tradeoffs as a Function of Vehicle Parameters

Fire survivability depends on the detection of and response to a fire before it has produced an unacceptable environment in the vehicle. This detection time is the result of interplay between the fire burning and growth rates; the vehicle size; the detection system design; the transport time to the detector (controlled by the level of mixing in the vehicle); and the rate at which the life support system filters the atmosphere, potentially removing the detected species or particles. Given the large differences in critical vehicle parameters (volume, mixing rate and filtration rate) the detection approach that works for a large vehicle (e.g. the ISS) may not be the best choice for a smaller crew capsule. This paper examines the impact of vehicle size and environmental control and life support system parameters on the detectability of fires in comparison to the hazard they present. A lumped element model was developed that considers smoke, heat, and toxic product release rates in comparison to mixing and filtration rates in the vehicle. Recent work has quantified the production rate of smoke and several hazardous species from overheated spacecraft polymers. These results are used as the input data set in the lumped element model in combination with the transport behavior of major toxic products released by overheating spacecraft materials to evaluate the necessary alarm thresholds to enable appropriate response to the fire hazard.

microgravity↗

Fire Detection Tradeoffs as a Function of Vehicle Parameters

Fire survivability depends on the detection of and response to a fire before it has produced an unacceptable environment in the vehicle. This detection time is the result of interplay between the fire burning and growth rates; the vehicle size; the detection system design; the transport time to the detector (controlled by the level of mixing in the vehicle); and the rate at which the life support system filters the atmosphere, potentially removing the detected species or particles. Given the large differences in critical vehicle parameters (volume, mixing rate and filtration rate) the detection approach that works for a large vehicle (e.g. the ISS) may not be the best choice for a smaller crew capsule. This paper examines the impact of vehicle size and environmental control and life support system parameters on the detectability of fires in comparison to the hazard they present. A lumped element model was developed that considers smoke, heat, and toxic product release rates in comparison to mixing and filtration rates in the vehicle. Recent work has quantified the production rate of smoke and several hazardous species from overheated spacecraft polymers. These results are used as the input data set in the lumped element model in combination with the transport behavior of major toxic products released by overheating spacecraft materials to evaluate the necessary alarm thresholds to enable appropriate response to the fire hazard.

microgravity↗

Development of Algorithms and Error Analyses for the Short Baseline Lightning Detection and Ranging System

NASA, at the John F. Kennedy Space Center (KSC), developed and operates a unique high-precision lightning location system to provide lightning-related weather warnings. These warnings are used to stop lightning- sensitive operations such as space vehicle launches and ground operations where equipment and personnel are at risk. The data is provided to the Range Weather Operations (45th Weather Squadron, U.S. Air Force) where it is used with other meteorological data to issue weather advisories and warnings for Cape Canaveral Air Station and KSC operations. This system, called Lightning Detection and Ranging (LDAR), provides users with a graphical display in three dimensions of 66 megahertz radio frequency events generated by lightning processes. The locations of these events provide a sound basis for the prediction of lightning hazards. This document provides the basis for the design approach and data analysis for a system of radio frequency receivers to provide azimuth and elevation data for lightning pulses detected simultaneously by the LDAR system. The intent is for this direction-finding system to correct and augment the data provided by LDAR and, thereby, increase the rate of valid data and to correct or discard any invalid data. This document develops the necessary equations and algorithms, identifies sources of systematic errors and means to correct them, and analyzes the algorithms for random error. This data analysis approach is not found in the existing literature and was developed to facilitate the operation of this Short Baseline LDAR (SBLDAR). These algorithms may also be useful for other direction-finding systems using radio pulses or ultrasonic pulse data.

Starr, Stanley O.↗

Data vs. MC Comparison of Light Signal from Cosmic Rays in the ICARUS Detectors

Currently, the ICARUS-T600 liquid argon TPC is collecting data exposed to Booster Neutrino and Numi off-axis beams within the SBN program at Fermilab. A light detection system, based on PMTs deployed behind the TPC wire chambers, is in place to detect vacuum ultraviolet photons produced by ionizing particles in LAr. This system is fundamental for the detector operation, providing an efficient trigger and contributing to the 3D reconstruction of events. Moreover, since the TPC is exposed to a huge flux of cosmic rays due to its operations at shallow depths, the light detection system allows for the time reconstruction of events, contributing to the identification and to the selection of neutrino interactions within the beam spill gates. This contribution will primarily focus on the comparative study (data vs. MC) of light signal of cosmic muons to validate the light emulation.

43 PARTICLE ACCELERATORS↗