Search NASA⌕ Search

SEARCH · Search NASA

Results for “dilation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,050 records · Page 59

Diagnosing Thermonuclear Burn in Fusion Implosions using Ultra-Fast Gas Cherenkov Detectors [Slides]

This presentations addresses these questions. What is fusion and what is ignition? How does LASER driven Inertial Confinement Fusion work? What can we measure and what does it tell us about fusion? How do Gas Cherenkov detectors work and what do they tell us? What are our plans for the future? In brief, the take away messages for this presentation are as follows: DT fusion reaction history provides crucial physics for ICF; gamma reaction history diagnostics are ready to resolve burn width on ignition shots; and GCDs have a lot of potential solving some of the questions related to fusion science.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stress- and Chemistry-Mediated Permeability Enhancement/Degradation in Stimulated Critically-Stressed Fractures

This work has investigated the interactions between stress and chemistry in controlling the evolution of permeability in stimulated fractured reservoirs through an integrated program of experimentation and modeling. Flow-through experiments on natural and artificial fractures in Coso diorite have examined the evolution of permeability under paths of mean and deviatoric stresses, including the role of dissolution and precipitation. Models accommodating these behaviors have examined the importance of incorporating the complex couplings between stress and chemistry in examining the evolution of permeability in EGS reservoirs. This document reports the findings of experiment [1,2] and analysis [3,4], in four sequential chapters.

15 GEOTHERMAL ENERGY↗

Thermodynamic Relations among Isotropic Material Properties in Conditions of Plane Shear Stress

We present new general relationships among the material properties of an isotropic material kept in homogeneous stress conditions with hydrostatic pressure and plane shear. The derivation is not limited to the proximity of the zero shear-stress and -strain condition, which allows us to identify the relationship between adiabatic and isothermal shear compliances (inverse of the moduli of rigidity) along with new links, among others, between isobaric and isochoric shear thermal expansion coefficients and heat capacities at constant stress and constant shear strain. Such relationships are important for a variety of applications, including the determination of constitutive equations, the characterization of nanomaterials, and the identification of properties related to earthquakes precursors and complex media (e.g., soil) behavior. The results may be useful to investigate the behavior of materials during phase transitions involving shear or in non-homogeneous conditions within a local thermodynamic equilibrium framework.

36 MATERIALS SCIENCE↗

Qubit Lattice Algorithms Based on the Schrödinger-Dirac Representation of Maxwell Equations and Their Extensions

It is well known that Maxwell equations can be expressed in a unitary Schrodinger-Dirac representation for homogeneous media. However, difficulties arise when considering inhomogeneous media. A Dyson map points to a unitary field qubit basis, but the standard qubit lattice algorithm of interleaved unitary collision-stream operators must be augmented by some sparse non-unitary potential operators that recover the derivatives on the refractive indices. Here, the effect of the steepness of these derivatives on two-dimensional scattering is examined with simulations showing quite complex wavefronts emitted due to transmissions/reflections within the dielectric objects. Maxwell equations are extended to handle dissipation using Kraus operators. Then, our theoretical algorithms are extended to these open quantum systems. A quantum circuit diagram is presented as well as estimates on the required number of quantum gates for implementation on a quantum computer.

2D electromagnetic scattering↗

Pulmonary venous flows reflect changes in left atrial hemodynamics during mitral balloon valvotomy

Patients with mitral stenosis have usually blunted pulmonary venous (PV) flow, because of decreased mitral valve area and diastolic dysfunction. The authors compared changes in Doppler PV velocities by using transesophageal echocardiography (TEE) against hemodynamics parameters before and after mitral balloon valvotomy to observe relevance of PV velocities and endsystolic left atrial (LA) pressure-volume relationship. In 25 patients (aged 35 +/- 17 years) with mitral stenosis in sinus rhythm, changes in LA pressure and volumes were compared with PV velocities before and after valvotomy. Mitral valve area, mitral gradients, and deceleration time were obtained. Mitral valve area and mitral gradients changed from 1 +/- 0.2 cm2 and 14.6 +/- 5.4 mmHg to 1.9 +/- 0.3 cm2 and 6.3 +/- 1.7 mmHg, respectively (p<0.001). AR peak reverse flow velocity and AR duration decreased from 29 +/- 13 cm/s and 110 =/- 30 msec to 19 +/- 6 cm/s and 80 +/- 29 msec respectively (p<0.001). Transmitral Doppler E wave deceleration time decreased from 327 +/- 85 to 209 +/- 61 s and cardiac output increased from 4.2 +/- 1.0 to 5.2 +/- 1.1 L/minute (p<0.001). The changes in LA pressure were correlated with changes in S/D (r=0.57, p<0.05). The changes in endsystolic LA pressure-volume relationship were also correlated with changes in S/D (r=0.52, p<0.05). Endsystolic LA pressure-volume relationship decreased after mitral balloon valvotomy, as a result of a large decrease in pressure. PV systolic/diastolic (S/D) waves ratio reflects endsystolic LA pressure-volume relationship and may be used as another indicator of successful valvotomy.

Non-NASA Center↗

Anatomical and functional characteristics of carotid sinus stimulation in humans

Transmission characteristics of pneumatic pressure to the carotid sinus were evaluated in 19 subjects at rest and during exercise. Either a percutaneous fluid-filled (n = 12) or balloon-tipped catheter (n = 7) was placed at the carotid bifurcation to record internal transmission of external neck pressure/neck suction (NP/NS). Sustained, 5-s pulses, and rapid ramping pulse protocols (+40 to -80 Torr) were recorded. Transmission of pressure stimuli was less with the fluid-filled catheter compared with that of the balloon-tipped catheter (65% vs. 82% negative pressure, 83% vs. 89% positive pressure; P < 0.05). Anatomical location of the carotid sinus averaged 3.2 cm (left) and 3.6 cm (right) from the gonion of the mandible with a range of 0-7.5 cm. Transmission was not altered by exercise or Valsalva maneuver, but did vary depending on the position of the carotid sinus locus beneath the sealed chamber. These data indicate that transmission of external NP/NS was higher than previously recorded in humans, and anatomical variation of carotid sinus location and equipment design can affect transmission results.

Randomized Controlled Trial↗