Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct simulation Monte Carlo methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

A study of phonon anisotropic scattering effect on silicon thermal conductivity at nanoscale

Previous studies have shown that anisotropy in phonon transport exist because of the difference in phonon dispersion relation due to different lattice direction, as observed by a difference in in-plane and cross-plane thermal conductivity. The directional preference (such as forward or backward scattering) in phonon propagation however, remains a relatively unexplored frontier. Our current work adopts a simple scattering probability in radiative transfer, which is called Henyey and Greenstein probability density function, and incorporates it into the phonon Monte Carlo simulation to investigate the effect of directional scattering in phonon transport. In this work, the effect of applying the anisotropy scattering is discussed, as well as its impact on the simulated thermal conductivity of silicon thin films. While the forward and backward scattering will increase and decrease thermal conductivity respectively, the extent of the effect is non-linear such that forward scattering has a more obvious effect than backward scattering.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Kilovoltage energy imaging with a radiotherapy linac with a continuously variable energy range

Purpose: In this paper, the effect on image quality of significantly reducing the primary electron energy of a radiotherapy accelerator is investigated using a novel waveguide test piece. The waveguide contains a novel variable coupling device (rotovane), allowing for a wide continuously variable energy range of between 1.4 and 9 MeV suitable for both imaging and therapy.Method: Imaging at linac accelerating potentials close to 1 MV was investigated experimentally and via Monte Carlo simulations. An imaging beam line was designed, and planar and cone beam computed tomography images were obtained to enable qualitative and quantitative comparisons with kilovoltage and megavoltage imaging systems. The imaging beam had an electron energy of 1.4 MeV, which was incident on a water cooled electron window consisting of stainless steel, a 5 mm carbon electron absorber and 2.5 mm aluminium filtration. Images were acquired with an amorphous silicon detector sensitive to diagnostic x-ray energies. Results: The x-ray beam had an average energy of 220 keV and half value layer of 5.9 mm of copper. Cone beam CT images with the same contrast to noise ratio as a gantry mounted kilovoltage imaging system were obtained with doses as low as 2 cGy. This dose is equivalent to a single 6 MV portal image. While 12 times higher than a 100 kVp CBCT system (Elekta XVI), this dose is 140 times lower than a 6 MV cone beam imaging system and 6 times lower than previously published LowZ imaging beams operating at higher (4-5 MeV) energies. Conclusions: The novel coupling device provides for a wide range of electron energies that are suitable for kilovoltage quality imaging and therapy. The imaging system provides high contrast images from the therapy portal at low dose, approaching that of gantry mounted kilovoltage x-ray systems. Additionally, the system provides low dose imaging directly from the therapy portal, potentially allowing for target tracking during radiotherapy treatment. There is the scope with such a tuneable system for further energy reduction and subsequent improvement in image quality.

43 PARTICLE ACCELERATORS↗

MO-E-17A-05: Individualized Patient Dosimetry in CT Using the Patient Dose (PATDOSE) Algorithm

Purpose: Radiation dose to the patient undergoing a CT examination has been the focus of many recent studies. While CTDIvol and SSDE-based methods are important tools for patient dose management, the CT image data provides important information with respect to CT dose and its distribution. Coupled with the known geometry and output factors (kV, mAs, pitch, etc.) of the CT scanner, the CT dataset can be used directly for computing absorbed dose. Methods: The HU numbers in a patient's CT data set can be converted to linear attenuation coefficients (LACs) with some assumptions. With this (PAT-DOSE) method, which is not Monte Carlo-based, the primary and scatter dose are computed separately. The primary dose is computed directly from the geometry of the scanner, x-ray spectrum, and the known patient LACs. Once the primary dose has been computed to all voxels in the patient, the scatter dose algorithm redistributes a fraction of the absorbed primary dose (based on the HU number of each source voxel), and the methods here invoke both tissue attenuation and absorption and solid angle geometry. The scatter dose algorithm can be run N times to include Nth-scatter redistribution. PAT-DOSE was deployed using simple PMMA phantoms, to validate its performance against Monte Carlo-derived dose distributions. Results: Comparison between PAT-DOSE and MCNPX primary dose distributions showed excellent agreement for several scan lengths. The 1st-scatter dose distributions showed relatively higher-amplitude, long-range scatter tails for the PAT-DOSE algorithm then for MCNPX simulations. Conclusion: The PAT-DOSE algorithm provides a fast, deterministic assessment of the 3-D dose distribution in CT, making use of scanner geometry and the patient image data set. The preliminary implementation of the algorithm produces accurate primary dose distributions however achieving scatter distribution agreement is more challenging. Addressing the polyenergetic x-ray spectrum and spatially dependent scatter fractions will improve algorithm accuracy. Funding Support: UC Davis Clinical and Translational Science Center (CTSC) Award; NIH IMSD Student Fellowship; Saxon Student Fellowship Disclosure: PATENT Royalties from Samsung for dosimetry algorithm.

60 APPLIED LIFE SCIENCES↗

Minimally Invasive Treatment for Benign Prostatic Hyperplasia: Economic Evaluation from a Standardized Hospital Case Costing System

Purpose: Minimally invasive alternatives to transurethral resection of the prostate (TURP) such as prostate arterial embolization (PAE) and photoselective vaporization of the prostate (PVP) are being explored as adjuncts in the care of patients with benign prostatic hyperplasia. However, there are conflicting reports of the costs of these procedures. The purpose of this study was to compare the direct and indirect hospital costs of TURP, PAE and PVP. Materials and Methods: A chart review was performed in patients who underwent TURP, PVP and PAE from April 2015 to March 2017. All hospital costs were collected in accordance with the Ontario Case Costing Initiative, a standardized medical case costing system. Costs were characterized as direct or indirect and fixed or variable. Probabilistic sensitivity analysis was conducted to study cost uncertainty. Results: During the study period, a total of 209 men underwent TURP, 28 PVP and 21 PAE. Mean age (years) was as follows: TURP 71.43; PVP 73.66; PAE 70.77 (p = 0.366). Mean length of stay (days) was as follows: TURP 1.63; PVP 1.55; PAE 1 (p = 0.076). Total costs of the PAE group ($3829, SD $1582) were less than both PVP ($5719, SD $1515) and TURP groups ($5034, SD $1997, p < 0.001). There was no significant difference in direct costs between the groups. Monte Carlo simulation demonstrated that PAE was the least costly alternative majority of the time. Conclusions: The total hospital costs of PAE at our institution are significantly lower than those of PVP and TURP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SEC ‐ SAXS / MC Ensemble Structural Studies of the Microtubule Binding Protein Cdt1 Show Monomeric, Folded‐Over Conformations

ABSTRACT Cdt1 is a mixed folded protein critical for DNA replication licensing and it also has a “moonlighting” role at the kinetochore via direct binding to microtubules and the Ndc80 complex. However, it is unknown how the structure and conformations of Cdt1 could allow it to participate in these multiple, unique sets of protein complexes. While robust methods exist to study entirely folded or unfolded proteins, structure–function studies of combined, mixed folded/disordered proteins remain challenging. In this work, we employ orthogonal biophysical and computational techniques to provide structural characterization of mitosis‐competent human Cdt1. Thermal stability analyses shows that both folded winged helix domains1 are unstable. CD and NMR show that the N‐terminal and linker regions are intrinsically disordered. DLS shows that Cdt1 is monomeric and polydisperse, while SEC‐MALS confirms that it is monomeric at high concentrations, but without any apparent inter‐molecular self‐association. SEC‐SAXS enabled computational modeling of the protein structures. Using the program SASSIE, we performed rigid body Monte Carlo simulations to generate a conformational ensemble of structures. We observe that neither fully extended nor extremely compact Cdt1 conformations are consistent with SAXS. The best‐fit models have the N‐terminal and linker disordered regions extended into the solution and the two folded domains close to each other in apparent “folded over” conformations. We hypothesize the best‐fit Cdt1 conformations could be consistent with a function as a scaffold protein that may be sterically blocked without binding partners. Our study also provides a template for combining experimental and computational techniques to study mixed‐folded proteins.

Cell Biology↗

Ensemble approximate control variate estimators: Applications to multi-fidelity importance sampling.

The recent growth in multifidelity uncertainty quantification has given rise to a large set of variance reduction techniques that leverage information from model ensembles to provide variance reduction for estimates of the statistics of a high-fidelity model. In this paper we provide two contributions: (1) we utilize an ensemble estimator to account for uncertainties in the optimal weights of approximate control variate (ACV) approaches and derive lower bounds on the number of samples required to guarantee variance reduction; and (2) we extend an existing multifidelity importance sampling (MFIS) scheme to leverage control variates. Our approach directly addresses a limitation of many multifidelity sampling strategies that require the usage of pilot samples to estimate covariances. As such we make significant progress towards both increasing the practicality of approximate control variates—for instance, by accounting for the effect of pilot samples—and using multifidelity approaches more effectively for estimating low-probability events. The numerical results indicate our hybrid MFIS-ACV estimator achieves up to 50% improvement in variance reduction over the existing state-of-the-art MFIS estimator, which had already shown an outstanding convergence rate compared to the Monte Carlo method, on several problems of computational mechanics.

97 MATHEMATICS AND COMPUTING↗

Studies of a lattice model of water confined in a slit pore.

We describe an extension of the Bell-Salt lattice model of water to the study of water confined in a slit pore. Wall-fluid interactions are chosen to be qualitatively representative of water interacting with a graphite surface. We have calculated the bulk vapor-liquid phase coexistence for the model through direct Monte Carlo simulations of the vapor-liquid interface. Adsorption and desorption isotherms in the slit pore were calculated using grand canonical ensemble Monte Carlo simulations. In addition, the thermodynamic conditions of vapor-liquid equilibrium for the confined fluid were determined. Our results are consistent with recent calculations for off-lattice models of confined water that show metastable vapor states of confined water persisting beyond the bulk saturation conditions, except for the narrowest pores. The results are similarly consistent with recent experiments on water adsorption in graphitized carbon black.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computation of the Transmitted and Polarized Scattered Fluxes by the Exoplanet HD 189733b in X-Rays

Thousands of exoplanets have been detected, but only one exoplanetary transit was potentially observed in X-rays from HD 189733A. What makes the detection of exoplanets so difficult in this band? To answer this question, we run Monte-Carlo radiative transfer simulations to estimate the amount of X-ray flux reprocessed by HD 189733b. Despite its extended evaporating atmosphere, we find that the X-ray absorption radius of HD 189733b at 0.7 keV, which is the mean energy of the photons detected in the 0.25–2 keV energy band by XMM-Newton , is ∼1.01 times the planetary radius for an atmosphere of atomic hydrogen and helium (including ions), and produces a maximum depth of ∼2.1% at ∼±46 minutes from the center of the planetary transit on the geometrically thick and optically thin corona. We compute numerically in the 0.25–2 keV energy band that this maximum depth is only of ∼1.6% at ∼±47 minutes from the transit center, and not very sensitive to the metal abundance, assuming that adding metals in the atmosphere would not dramatically change the density–temperature profile. Regarding a direct detection of HD 189733b in X-rays, we find that the amount of flux reprocessed by the exoplanetary atmosphere varies with the orbital phase, spanning between three and five orders of magnitude fainter than the flux of the primary star. Additionally, the degree of linear polarization emerging from HD 189733b is <0.003%, with maximums detected near planetary greatest elongations. This implies that both the modulation of the X-ray flux with the orbital phase and the scatter-induced continuum polarization cannot be observed with current X-ray facilities.

79 ASTRONOMY AND ASTROPHYSICS↗

Predicting Flow in Fracture Networks With Quantum Algorithms

Uncertainty quantification plays a crucial role in the modeling of subsurface flow. For instance, uncertainties in the properties of geologic fracture networks significantly impact flow, requiring numerous simulations to accurately estimate quantities of interest. However, each simulation is computationally expensive because it requires solving a large linear system to capture features that involve both small and large fractures. An example is in percolation, where the interaction of many small fractures (which cumulatively can have a large surface area) with the rock matrix must be modeled precisely. Quantum computing is an emerging tool with the potential to address this issue. Quantum algorithms offer a significant speedup in solving linear systems, achieving efficiencies that are challenging to match with classical approaches. These classical approaches include direct solvers, such as LU decomposition, and iterative methods, notably preconditioned conjugate gradient, commonly used in subsurface modeling to solve large sparse systems. However, applying quantum algorithms to geologic fracture flow requires careful attention to algorithmic and problem-specific constraints to fully realize this quantum advantage. In this work we describe a quantum algorithm for generalized Monte Carlo applications with a quadratic speedup over the classical approaches which can be combined with the quantum speedup, currently under investigation, for solving quantum linear systems for subsurface flow. We show that for quantum algorithms the computational cost of estimating a quantity of interest for a statistical ensemble of networks is roughly the same as that of a single realization, essentially implying that one can get uncertainty quantification for free.

58 GEOSCIENCES↗

Demonstration of Comprehensive Ex-Vessel Fluence Capability

Several recent developments in the Consortium for Advanced Simulation of Light Water Reactors’ (CASL) Virtual Environment for Reactor Applications (VERA) were tested to highlight its capability to perform ex-vessel fluence and reaction rate calculations. VERA offers unique capabilities for integrating the deterministic neutronics code, MPACT, with Shift, a Monte Carlo code, to perform high-fidelity in-core and ex-core radiation transport. Applications such as pressure vessel fluence, ex-core detector response, and coupon irradiation analyses take advantage of this coupling. For these applications, MPACT performs the in-core radiation transport with temperature feedback and isotopic depletion through the direct coupling with the CTF subchannel thermal-hydraulics code. Then, MPACT provides the fission source to Shift for a follow-on fixed source radiation transport calculation that tallies all the ex-core responses of interest for each time-dependent statepoint. The variance reduction method, CADIS, which is implemented in Shift, allows for efficient performance of ex-core transport for calculation of ex-core quantities of interest. This milestone report identifies limitations to the current methodology in place and showcases VERA’s current capability to model ex-core quantities of interest.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Improvement and Verification of Online Cross Section Generation Capability of Griffin for TRISO-fueled Reactors

Griffin, a MOOSE-based reactor multiphysics code jointly developed by Idaho National Laboratory and Argonne National Laboratory under the DOE Office of Nuclear Energy’s NEAMS program, has pursued the development of an online multigroup cross section generation capability for a few years to enable high-fidelity, problem-dependent neutronics analyses of advanced thermal reactors. Recent advancements in Griffin’s online multigroup cross section generation capability have significantly improved the accuracy, robustness, and efficiency of self-shielding calculations for both prismatic and pebble-bed TRISO-fueled reactor applications. Key developments include a unified fuel self-shielding method applicable to both TRISO and annular compact/spherical shell fuel zone geometries; an advanced Dancoff Category-based Equivalence Theory using a bell function for non-fuel resonance treatment, achieving more than an order-of-magnitude speedup compared to the Tone method; an on-the-fly multigroup equivalence approach to mitigate group condensation errors; and a streaming correction method for pebble-bed homogenization. A proof-of-concept demonstration of on-the-fly group condensation with consistent P0 transport correction was also achieved. The method reproduced direct fine-group solutions with excellent accuracy (eigenvalue errors within 10 pcm and pin-power differences within 0.5%), but due to performance limitations of the current fixed-source solver, improvements to solver efficiency will be addressed in future work. Verification tests were performed on graphite-moderated TRISO-fueled two-dimensional core benchmark problems representing gas-cooled microreactors, heat pipe-cooled microreactors, gas-cooled pebble-bed reactors, and fluoride salt-cooled high-temperature reactors. Across all cases, Griffin showed excellent agreement with Serpent2 continuous energy Monte Carlo solutions: eigenvalue errors within 200 pcm, pin-power root-mean-square errors within 2%, and control rod and drum worth errors less than 2%. It should be noted that, for the benchmark problem, cross section generation contributed less than 3% of the total simulation times. These results demonstrate that Griffin’s online cross section generation capability delivers accurate and efficient reactor physics solutions across a wide spectrum of TRISO-fueled advanced reactor designs. With further improvements to the fine-group fixed-source solver and planned extensions to depletion, transients, and coupled neutron–gamma transport, Griffin will be well-positioned to become a powerful and comprehensive tool for advanced reactor analysis.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The 3-D world modeling with updating capability based on combinatorial geometry

A 3-D world modeling technique using range data is discribed. Range data quantify the distances from the sensor focal plane to the object surface, i.e., the 3-D coordinates of discrete points on the object surface are known. The approach proposed herein for 3-D world modeling is based on the Combinatorial Geometry (CG) method which is widely used in Monte Carlo particle transport calculations. First, each measured point on the object surface is surrounded by a small sphere with a radius determined by the range to that point. Then, the 3-D shapes of the visible surfaces are obtained by taking the (Boolean) union of all the spheres. The result is an unambiguous representation of the object's boundary surfaces. The pre-learned partial knowledge of the environment can be also represented using the CG Method with a relatively small amount of data. Using the CG type of representation, distances in desired directions to boundary surfaces of various objects are efficiently calculated. This feature is particularly useful for continuously verifying the world model against the data provided by a range finder, and for integrating range data from successive locations of the robot during motion. The efficiency of the proposed approach is illustrated by simulations of a spherical robot in a 3-D room in the presence of moving obstacles and inadequate prelearned partial knowledge of the environment.

Goldstein, M.↗

Simulation Study of Toroidal Shear Flow Generation by a Local ICRF Heating

The toroidal shear flow generation by a local ICRF heating is studied using GNET code, in which the drift kinetic equation is solved in 5D phase-space. Verification of the Ohkawa model [T. Ohkawa and Miller, Phys. Plasmas 12(2005) 094506.] predicting the toroidal shear flow generation is done including the finite orbit effect of energetic ions in a tokamak configuration. The Alcator C-mod plasma is assumed as a first step. A co-directional toroidal flow outside of the power absorption region (resonance position) is observed. The dominant part of toroidal flow dose not depend on the sign k{sub ||} and this fact indicates that the driving mechanism of the dominant part is different from that proposed by the Ohkawa model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stellar granulation as the source of high-frequency flicker in Kepler light curves

A large fraction of cool, low-mass stars exhibit brightness fluctuations that arise from a combination of convective granulation, acoustic oscillations, magnetic activity, and stellar rotation. Much of the short-timescale variability takes the form of stochastic noise, whose presence may limit the progress of extrasolar planet detection and characterization. In order to lay the groundwork for extracting useful information from these quasi-random signals, we focus on the origin of the granulation-driven component of the variability. We apply existing theoretical scaling relations to predict the star-integrated variability amplitudes for 508 stars with photometric light curves measured by the Kepler mission. We also derive an empirical correction factor that aims to account for the suppression of convection in F-dwarf stars with magnetic activity and shallow convection zones. So that we can make predictions of specific observational quantities, we performed Monte Carlo simulations of granulation light curves using a Lorentzian power spectrum. These simulations allowed us to reproduce the so-called flicker floor (i.e., a lower bound in the relationship between the full light-curve range and power in short-timescale fluctuations) that was found in the Kepler data. The Monte Carlo model also enabled us to convert the modeled fluctuation variance into a flicker amplitude directly comparable with observations. When the magnetic suppression factor described above is applied, the model reproduces the observed correlation between stellar surface gravity and flicker amplitude. Observationally validated models like these provide new and complementary evidence for a possible impact of magnetic activity on the properties of near-surface convection.

79 ASTRONOMY AND ASTROPHYSICS↗

Testicular Doses in Image-Guided Radiotherapy of Prostate Cancer

Purpose: To investigate testicular doses contributed by kilovoltage cone-beam computed tomography (kVCBCT) during image-guided radiotherapy (IGRT) of prostate cancer. Methods and Materials: An EGS4 Monte Carlo code was used to calculate three-dimensional dose distributions from kVCBCT on 3 prostate cancer patients. Absorbed doses to various organs were compared between intensity-modulated radiotherapy (IMRT) treatments and kVCBCT scans. The impact of CBCT scanning mode, kilovoltage peak energy (kVp), and CBCT field span on dose deposition to testes and other organs was investigated. Results: In comparison with one 10-MV IMRT treatment, a 125-kV half-fan CBCT scan delivered 3.4, 3.8, 4.1, and 5.7 cGy to the prostate, rectum, bladder, and femoral heads, respectively, accounting for 1.7%, 3.2%, 3.2%, and 8.4% of megavoltage photon dose contributions. However, the testes received 2.9 cGy from the same CBCT scan, a threefold increase as compared with 0.7 cGy received during IMRT. With the same kVp, full-fan mode deposited much less dose to organs than half-fan mode, ranging from 9% less for prostate to 69% less for testes, except for rectum, where full-fan mode delivered 34% more dose. As photon beam energy increased from 60 to 125 kV, kVCBCT-contributed doses increased exponentially for all organs, irrespective of scanning mode. Reducing CBCT field span from 30 to 10 cm in the superior-inferior direction cut testicular doses from 5.7 to 0.2 cGy in half-fan mode and from 1.5 to 0.1 cGy in full-fan mode. Conclusions: Compared with IMRT, kVCBCT-contributed doses to the prostate, rectum, bladder, and femoral heads are clinically insignificant, whereas dose to the testes is threefold more. Full-fan CBCT usually deposits much less dose to organs (except for rectum) than half-fan mode in prostate patients. Kilovoltage CBCT-contributed doses increase exponentially with photon beam energy. Reducing CBCT field significantly cuts doses to testes and other organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modulation of intensity emerging from zero effort (MIEZE) with extended Fourier time at large scattering angle

Modulation of Intensity Emerging from Zero Effort (MIEZE) is a neutron resonant spin echo technique that allows one to measure time correlation scattering functions in materials by implementing radio-frequency (RF) intensity modulation at the sample and the detector. The technique avoids neutron spin manipulation between the sample and the detector and, thus, could find applications in cases where the sample depolarizes the neutron beam. However, the finite sample size creates a variance in the path length between the locations where scattering and detection happen, which limits the contrast in intensity modulation that one can detect, in particular, toward long correlation times or large scattering angles. We propose a modification to the MIEZE setup that will enable one to extend those detection limits to longer times and larger angles. Furthermore, we use Monte Carlo simulations of a neutron scattering beamline to show that by tilting the RF flippers in the primary spectrometer with respect to the beam direction, one can shape the wave front of the intensity modulation at the sample to compensate for the path variance from the sample and the detector. The simulation results indicate that this change enables one to operate a MIEZE instrument at much increased RF frequencies, thus improving the effective energy resolution of the technique. For the MIEZE instrument simulated, it shows that for an incident beam with the maximum divergence of 0.33°, the maximum Fourier time can be increased by a factor of 3.

47 OTHER INSTRUMENTATION↗

High average-flux laser-driven neutron source

Laser-driven neutron generation is an attractive alternative to more established methods for compact, short-pulse-duration neutron sources with applications in medical science, material science and imaging. Despite extensive investigation of various techniques, achieving performance comparable to nuclear reactors or conventional accelerators remains challenging. In this work, we generate a stable, high-repetition-rate laser-driven neutron source reaching a record average flux of 7.8 × 10 7 n/sr/s, improving on other existing laser-based sources by more than one order of magnitude. Our approach is based on a two-step process where electrons are accelerated to relativistic energies via laser wakefield acceleration (LWFA), and subsequently generate neutrons through Bremsstrahlung emission followed by photonuclear reactions in a tungsten converter. Experimental results, supported by Monte Carlo simulations, show a neutron flux of 3.0 × 10 7 n/cm 2 /s near the target, on par with some compact accelerator-based neutron sources. Additionally, a direct comparison with the target-normal sheath acceleration (TNSA) pitcher-catcher scheme, performed on the same laser system, reveals a significantly higher total neutron yield of 3.9 × 10 8 neutrons per shot, outperforming the TNSA scheme by several orders of magnitude. These findings represent a significant advancement towards the development of practical laser-driven neutron sources and highlight the advantages of LWFA-based neutron generation for future applications.

Vallières, Simon [Institut National de la Recherch↗

Non-destructive Assay Measurements Using the RPI Lead Slowing Down Spectrometer

The use of a Lead Slowing-Down Spectrometer (LSDS) is consid- ered as a possible option for non-destructive assay of fissile material of used nuclear fuel. The primary objective is to quantify the 239Pu and 235U fissile content via a direct measurement, distinguishing them through their characteristic fission spectra in the LSDS. In this pa- per, we present several assay measurements performed at the Rensse- laer Polytechnic Institute (RPI) to demonstrate the feasibility of such a method and to provide benchmark experiments for Monte Carlo cal- culations of the assay system. A fresh UOX fuel rod from the RPI Criticality Research Facility, a 239PuBe source and several highly en- riched 235U discs were assayed in the LSDS. The characteristic fission spectra were measured with 238U and 232Th threshold fission cham- bers, which are only sensitive to fission neutron with energy above the threshold. Despite the constant neutron and gamma background from the PuBe source and the intense interrogation neutron flux, the LSDS system was able to measure the characteristic 235U and 239Pu responses. All measurements were compared to Monte Carlo simula- tions. It was shown that the available simulation tools and models are well suited to simulate the assay, and that it is possible to calculate the absolute count rate in all investigated cases.

Lead Slowing Down Spectrometer↗