Search NASA⌕ Search

SEARCH · Search NASA

Results for “errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Error Bounds for Dynamical Spectral Estimation

Dynamical spectral estimation is a well-established numerical approach for estimating eigenvalues and eigenfunctions of the Markov transition operator from trajectory data. Although the approach has been widely applied in biomolecular simulations, its error properties remain poorly understood. Here we analyze the error of a dynamical spectral estimation method called “the variational approach to conformational dynamics" (VAC). We bound the approximation error and estimation error for VAC estimates. Our analysis establishes VAC's convergence properties and suggests new strategies for tuning VAC to improve accuracy.

97 MATHEMATICS AND COMPUTING↗

Class-specific Error Bounds for Ensemble Classifiers

The generalization error, or probability of misclassification, of ensemble classifiers has been shown to be bounded above by a function of the mean correlation between the constituent (i.e., base) classifiers and their average strength. This bound suggests that increasing the strength and/or decreasing the correlation of an ensemble's base classifiers may yield improved performance under the assumption of equal error costs. However, this and other existing bounds do not directly address application spaces in which error costs are inherently unequal. For applications involving binary classification, Receiver Operating Characteristic (ROC) curves, performance curves that explicitly trade off false alarms and missed detections, are often utilized to support decision making. To address performance optimization in this context, we have developed a lower bound for the entire ROC curve that can be expressed in terms of the class-specific strength and correlation of the base classifiers. We present empirical analyses demonstrating the efficacy of these bounds in predicting relative classifier performance. In addition, we specify performance regions of the ROC curve that are naturally delineated by the class-specific strengths of the base classifiers and show that each of these regions can be associated with a unique set of guidelines for performance optimization of binary classifiers within unequal error cost regimes.

99 GENERAL AND MISCELLANEOUS↗

Extending Moore's Law via Computationally Error Tolerant Computing.

Dennard scaling has ended. Lowering the voltage supply (V dd ) to sub-volt levels causes intermittent losses in signal integrity, rendering further scaling (down) no longer acceptable as a means to lower the power required by a processor core. However, it is possible to correct the occasional errors caused due to lower V dd in an efficient manner and effectively lower power. By deploying the right amount and kind of redundancy, we can strike a balance between overhead incurred in achieving reliability and energy savings realized by permitting lower V dd . One promising approach is the Redundant Residue Number System (RRNS) representation. Unlike other error correcting codes, RRNS has the important property of being closed under addition, subtraction and multiplication, thus enabling computational error correction at a fraction of an overhead compared to conventional approaches. We use the RRNS scheme to design a Computationally-Redundant, Energy-Efficient core, including the microarchitecture, Instruction Set Architecture (ISA) and RRNS centered algorithms. Finally, from the simulation results, this RRNS system can reduce the energy-delay-product by about 3× for multiplication intensive workloads and by about 2× in general, when compared to a non-error-correcting binary core.

97 MATHEMATICS AND COMPUTING↗

Nonlinear Advection Algorithms Applied to Inter-related Tracers: Errors and Implications for Modeling Aerosol-Cloud Interactions

Monotonicity constraints and gradient preserving flux corrections employed by many advection algorithms used in atmospheric models make these algorithms non-linear. Consequently, any relations among model variables transported separately are not necessarily preserved in such models. These errors cannot be revealed by traditional algorithm testing based on advection of a single tracer. New type of tests are developed and conducted to evaluate the preservation of a sum of several number mixing ratios advected independently of each other, as is the case, for example, in models using bin or sectional representation of aerosol or cloud particle size distribution. The tests show that when three tracers are advected in 1D uniform constant velocity flow, local errors in the sum can be on the order of 10%. When cloud-like interactions are allowed among the tracers, errors in total sum of three mixing ratios can reach up to 30%. Several approaches to eliminate the error are suggested, all based on advecting the sum as a separate variable and then normalizing mixing ratios for individual tracers to match the total sum. A simple scalar normalization preserves the total number mixing ratio and positive definiteness of the variables but the monotonicity constraint for individual tracers is no longer maintained. More involved flux normalization procedures are developed for the flux based advection algorithms to maintain the monotonicity for individual scalars and their sum.

54 ENVIRONMENTAL SCIENCES↗

Spatial Variability of Winds and HRRR–NCEP Model Error Statistics at Three Doppler-Lidar Sites in the Wind-Energy Generation Region of the Columbia River Basin

Annually and seasonally averaged wind profiles from three Doppler lidars were gathered from sites in the Columbia River basin of east-central Oregon and Washington, a major region of wind-energy production, for the Second Wind Forecast Improvement Project (WFIP2) experiment. The profile data are used to quantify the spatial variability of wind flows in this area of complex terrain, to assess the HRRR-NCEP model's ability to capture spatial and temporal variability of wind profiles, and to evaluate model errors. Annually averaged measured wind speed differences over the 70-km extent of the lidar measurements reached 1 m s -1 within the wind-turbine rotor layer, and 2 m s -1 for 200-500 m AGL. Stronger wind speeds in the lowest 500 m occurred at sites higher in elevation, farther from the river, and farther west - closer to the Cascade Mountain barrier. Validating against the lidar data, the HRRR model underestimated strong wind speeds (>12 m s -1 ) and, consequently, their frequency of occurrence, especially at the two lowest-elevation sites, producing annual low biases in rotor-layer wind speed of 0.5 m s -1 . The RMSE between measured and modeled winds at all sites was about 3 m s -1 and did not degrade significantly with forecast lead time. The nature of the model errors was different for different seasons. Furthermore, although the three sites were located in the same basin terrain, the nature of the model errors was different at each site. Thus, if only one of the sites had been instrumented, different conclusions would have been drawn as to the major sources of model error, depending on where the measurements were made.

17 WIND ENERGY↗

Real-time detection and elimination of nonorthogonality error in interference fringe processing

In the measurement system of interference fringe, the nonorthogonality error is a main error source that influences the precision and accuracy of the measurement system. The detection and elimination of the error has been an important target. A novel method that only uses the cross-zero detection and the counting is proposed to detect and eliminate the nonorthogonality error in real time. This method can be simply realized by means of the digital logic device, because it does not invoke trigonometric functions and inverse trigonometric functions. And it can be widely used in the bidirectional subdivision systems of a Moire fringe and other optical instruments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-step retrace error calibration removing tilt ambiguity in coherence scanning interferometry

In interferometry measurement, the retrace error often limits its high-precision metrology applications. Retrace error calibration with tilted flats can give a relation between the retrace error and the introduced tilt angles, but there is still an ambiguity between the introduced tilt angles and the tilt terms in the created retrace error. Here, we propose a novel, to the best of our knowledge, two-step calibration method to resolve this tilt ambiguity. It involves additional measurements of spherical mirror(s) with known curvature(s). The experiment shows that the curvature deviation due to the tilt ambiguity can be significantly reduced after applying the proposed method.

36 MATERIALS SCIENCE↗

A Bayesian Calibration Framework with Embedded Model Error for Model Diagnostics

We study the utility and performance of a Bayesian model error embedding construction in the context of molecular dynamics modeling of metallic alloys, where we embed model error terms in existing interatomic potential model parameters. To alleviate the computational burden of this approach, we propose a framework combining likelihood approximation and Gaussian process surrogates. Here we leverage sparse Gaussian process techniques to construct a hierarchy of increasingly accurate but more expensive surrogate models. This hierarchy is then exploited by multilevel Markov chain Monte Carlo methods to efficiently sample from the target posterior distribution. We illustrate the utility of this approach by calibrating an interatomic potential model for a family of gold-copper alloys. In particular, this case study highlights effective means for dealing with computational challenges with Bayesian model error embedding in large-scale physical models, and the utility of embedded model error for model diagnostics.

Bayesian inference↗

JLEIC electron ring dynamic aperture with non-linear field errors

We present results of dynamic aperture study for the updated electron ring lattice of the Jefferson Lab Electron- Ion Collider (JLEIC). The lattice design features low emittance arcs with local compensation of sextupole nonlinear effects, and low emittance non-linear chromaticity correction sections. Dynamic aperture tracking simulations are performed to evaluate the effects of non-linear field errors, the sensitivity to betatron tune, and the impact of momentum error. Dynamic aperture is also evaluated with the measured PEP-II field errors. Preliminary tolerances to the non-linear field errors in the Final Focus quadrupoles are estimated.

Nosochkov, Yuri↗

Dynamic Aperture of JLEIC Electron Collider Ring with Errors and Correction

Design of the electron and ion rings of the Jefferson Lab Electron-Ion Collider (JLEIC) features the low-beta Interaction Regions (IR) with detector solenoid, non-linear chromaticity compensation blocks (CCB), and spin rotator optics with solenoids. The high beta functions in the IR final focus quadrupoles (FFQ) and in the CCB magnets result in strong effects of errors in these magnets. Performance of the spin rotators may also be sensitive to the errors. The first part of this study includes the design of orbit correction system for both rings and evaluation of dynamic aperture (DA) with misalignment and the correction. The second part is devoted to the DA study with the FFQ non-linear field errors. The orbit correction design, the dynamic aperture, and the impact on error specifications are presented.

Lin, F.↗

Error Field Correction in DIII-D Ohmic Plasmas With Either Handedness

Error field correction results in DIII-D plasmas are presented in various configurations. In both left-handed and right-handed plasma configurations, where the intrinsic error fields become different due to the opposite helical twist (handedness) of the magnetic field, the optimal error correction currents and the toroidal phases of internal(I)-coils are empirically established. Applications of the Ideal Perturbed Equilibrium Code to these results demonstrate that the field component to be minimized is not the resonant component of the external field, but the total field including ideal plasma responses. Consistency between experiment and theory has been greatly improved along with the understanding of ideal plasma responses, but non-ideal plasma responses still need to be understood to achieve the reliable predictability in tokamak error field correction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Discretization error estimation and exact solution generation using the method of nearby problems.

The Method of Nearby Problems (MNP), a form of defect correction, is examined as a method for generating exact solutions to partial differential equations and as a discretization error estimator. For generating exact solutions, four-dimensional spline fitting procedures were developed and implemented into a MATLAB code for generating spline fits on structured domains with arbitrary levels of continuity between spline zones. For discretization error estimation, MNP/defect correction only requires a single additional numerical solution on the same grid (as compared to Richardson extrapolation which requires additional numerical solutions on systematically-refined grids). When used for error estimation, it was found that continuity between spline zones was not required. A number of cases were examined including 1D and 2D Burgers equation, the 2D compressible Euler equations, and the 2D incompressible Navier-Stokes equations. The discretization error estimation results compared favorably to Richardson extrapolation and had the advantage of only requiring a single grid to be generated.

99 GENERAL AND MISCELLANEOUS↗

Sensitivity to Error Fields in NSTX High β Plasmas

It was found that error field threshold decreases for high β in NSTX, although the density correlation in conventional threshold scaling implies the threshold would increase since higher β plasmas in our study have higher plasma density. This greater sensitivity to error field in higher β plasmas is due to error field amplification by plasmas. When the effect of amplification is included with ideal plasma response calculations, the conventional density correlation can be restored and threshold scaling becomes more consistent with low β plasmas. However, it was also found that the threshold can be significantly changed depending on plasma rotation. When plasma rotation was reduced by non-resonant magnetic braking, the further increase of sensitivity to error field was observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enabling Predictive Simulation and UQ of Complex Multiphysics PDE Systems by the Development of Goal-Oriented Variational Sensitivity Analysis and A Posteriori Error Estimation Methods

It was demonstrated that a posteriori analyses in general and in particular one that uses adjoint methods can accurately and efficiently compute numerical error estimates and sensitivity for critical Quantities of Interest (QoIs) that depend on a large number of parameters. Activities include: analysis and implementation of several time integration techniques for solving system of ODEs as typically obtained from spatial discretization of PDE systems; multirate integration methods for ordinary differential equations; formulation and analysis of an iterative multi-discretization Galerkin finite element method for multi-scale reaction-diffusion equations; investigation of an inexpensive postprocessing technique to estimate the error of finite element solution of the second-order quasi-linear elliptic problems measured in some global metrics; investigation of an application of the residual-based a posteriori error estimates to symmetric interior penalty discontinuous Galerkin method for solving a class of second order quasi-linear elliptic problems; a posteriori analysis of explicit time integrations for system of linear ordinary differential equations; derivation of accurate a posteriori goal oriented error estimates for a user-defined quantity of interest for two classes of first and second order IMEX schemes for advection-diffusion-reaction problems; Postprocessing finite element solution; and A Bayesian Framework for Uncertain Quantification of Porous Media Flows.

97 MATHEMATICS AND COMPUTING↗

Systematic Error Study for ALICE charged-jet v2 Measurement

We study the treatment of systematic errors in the determination of v 2 for charged jets in √ sNN = 2:76 TeV Pb-Pb collisions by the ALICE Collaboration. Working with the reported values and errors for the 0-5% centrality data we evaluate the Χ 2 according to the formulas given for the statistical and systematic errors, where the latter are separated into correlated and shape contributions. We reproduce both the Χ 2 and p-values relative to a null (zero) result. We then re-cast the systematic errors into an equivalent co-variance matrix and obtain identical results, demonstrating that the two methods are equivalent.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Error studies of Halbach Magnets

These error studies were done on the Halbach magnets for the CBETA “First Girder” as described in note [CBETA001]. The CBETA magnets have since changed slightly to the lattice in [CBETA009]. However, this is not a large enough change to significantly affect the results here. The QF and BD arc FFAG magnets are considered. For each assumed set of error distributions and each ideal magnet, 100 random magnets with errors are generated. These are then run through an automated version of the iron wire multipole cancellation algorithm. The maximum wire diameter allowed is 0.063” as in the proof-of-principle magnets. Initially, 32 wires (2 per Halbach wedge) are tried, then if this does not achieve 1e-­4 level accuracy in the simulation, 48 and then 64 wires. By “1e-4 accuracy”, it is meant the FOM defined by √(Σ n≥sextupole a n 2 +b n 2 ) is less than 1 unit, where the multipoles are taken at the maximum nominal beam radius, R=23mm for these magnets. The algorithm initially uses 20 convergence interations. If 64 wires does not achieve 1e-­4 accuracy, this is increased to 50 iterations to check for slow converging cases. There are also classifications for magnets that do not achieve 1e-4 but do achieve 1e-3 (FOM ≤ 10 units). This is technically within the spec discussed in the Jan 30, 2017 review; however, there will be errors in practical shimming not dealt with in the simulation, so it is preferable to do much better than the spec in the simulation.

43 PARTICLE ACCELERATORS↗

AEDAM: Whole Program Adaptive Error Detection and Mitigation (Final Report)

The overall goals of the AEDAM project were to fundamentally transform software transient-error detection through the design of configurable specialized detectors, quantitative characterization of hardware resilience and software vulnerabilities, and composition of the specialized detectors to most efficiently protect the whole program. Within this scope, UT Austin's research contribution related to enabling and studying the composition of detectors and possible different hardware errors, specifically: (1) developed the Hamartia open-source error injection framework that is designed to make composition studies simple, and (2) develop the methodology and demonstrate the potential benefits of error detector composition.

97 MATHEMATICS AND COMPUTING↗

Applying Multi-Frequency AC LOCO for Finding Sextupole Errors

A fast and precise technique of multi-frequency AC LOCO has been developed and tested for finding the sextupole alignment and field-offset errors at NSLS-II. This technique is based on sine-wave beam excitation simultaneously at multiple frequencies via different fast correctors. The unique combination of the fast speed and high measurement accuracy opens the door for two different types of potential applications: finding the sextupole alignment and field-offset errors. Beam excitation via fast correctors results in the elimination of the systematic error caused by the hysteresis effect. Systematic errors of the sextupole alignment caused by orbit drift and power supply calibration are also eliminated because the measurement takes only two minutes and does not depend on the current-to-field conversion of sextupole magnets. Furthermore, the simulation studies indicate that multi-frequency AC LOCO together with an orbit bump bigger than 0.5 mm can be applied to measure the relative field offset of a sextupole magnet with a precision better than 10%. The measurement technique is described and the results of two proof-of-principle experiments carried out at NSLS-II are presented.

43 PARTICLE ACCELERATORS↗