Search NASA⌕ Search

SEARCH · Search NASA

Results for “field protocols”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Electrical Interrogation of Thickness‐Dependent Multiferroic Phase Transitions in the 2D Antiferromagnetic Semiconductor NiI 2

Abstract 2D magnetic materials hold promise for quantum and spintronic applications. 2D antiferromagnetic materials are of particular interest due to their relative insensitivity to external magnetic fields and higher switching speeds compared to 2D ferromagnets. However, their lack of macroscopic magnetization impedes detection and control of antiferromagnetic order, thus motivating magneto‐electrical measurements for these purposes. Additionally, many 2D magnetic materials are ambient‐reactive and electrically insulating or highly resistive below their magnetic ordering temperatures, which imposes severe constraints on electronic device fabrication and characterization. Herein, these issues are overcome via a fabrication protocol that achieves electrically conductive devices from the ambient‐reactive 2D antiferromagnetic semiconductor NiI 2 . The resulting gate‐tunable transistors show band‐like electronic transport below the antiferromagnetic and multiferroic transition temperatures of NiI 2 , revealing a Hall mobility of 15 cm 2 V −1 s −1 at 1.7 K. These devices also allow direct electrical probing of the thickness‐dependent multiferroic phase transition temperature of NiI 2 from 59 K (bulk) to 28 K (monolayer).

2D magnets↗

Accelerated Total Lymphoid Irradiation-containing Salvage Regimen for Patients With Refractory and Relapsed Hodgkin Lymphoma: 20 Years of Experience

Purpose: We report the long-term results of integrated accelerated involved field radiation therapy (IFRT) followed by total lymphoid irradiation (TLI) as part of the high-dose salvage regimen followed by autologous bone marrow transplantation or autologous stem cell transplantation in patients with relapsed or refractory Hodgkin lymphoma (HL). Methods and Materials: From November 1985 to July 2008, 186 previously unirradiated patients with relapsed or refractory HL underwent salvage therapy on 4 consecutive institutional review board–approved protocols. All patients had biopsy-proven primary refractory or relapsed HL. After standard-dose salvage chemotherapy (SC), accelerated IFRT (18-20 Gy) was given to relapsed or refractory sites, followed by TLI (15-18 Gy) and high-dose chemotherapy. Overall survival (OS) and event-free survival (EFS) were analyzed by Cox analysis and disease-specific survival (DSS) by competing-risk regression. Results: With a median follow-up period of 57 months among survivors, 5- and 10-year OS rates were 68% and 56%, respectively; 5- and 10-year EFS rates were 62% and 56%, respectively; and 5- and 10-year cumulative incidences of HL-related deaths were 21% and 29%, respectively. On multivariate analysis, complete response to SC was independently associated with improved OS and EFS. Primary refractory disease and extranodal disease were independently associated with poor DSS. Eight patients had grade 3 or higher cardiac toxicity, with 3 deaths. Second malignancies developed in 10 patients, 5 of whom died. Conclusions: Accelerated IFRT followed by TLI and high-dose chemotherapy is an effective, feasible, and safe salvage strategy for patients with relapsed or refractory HL with excellent long-term OS, EFS, and DSS. Complete response to SC is the most important prognostic factor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analytical solution for nonadiabatic quantum annealing to arbitrary Ising spin Hamiltonian

Abstract Ising spin Hamiltonians are often used to encode a computational problem in their ground states. Quantum Annealing (QA) computing searches for such a state by implementing a slow time-dependent evolution from an easy-to-prepare initial state to a low energy state of a target Ising Hamiltonian of quantum spins, H I . Here, we point to the existence of an analytical solution for such a problem for an arbitrary H I beyond the adiabatic limit for QA. This solution provides insights into the accuracy of nonadiabatic computations. Our QA protocol in the pseudo-adiabatic regime leads to a monotonic power-law suppression of nonadiabatic excitations with time T of QA, without any signature of a transition to a glass phase, which is usually characterized by a logarithmic energy relaxation. This behavior suggests that the energy relaxation can differ in classical and quantum spin glasses strongly, when it is assisted by external time-dependent fields. In specific cases of H I , the solution also shows a considerable quantum speedup in computations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

False vacuum decay and nucleation dynamics in neutral atom systems

Metastable states of quantum many-body systems with confinement offer a means to simulate false vacuum phenomenology, including nonequilibrium dynamical processes like decay by nucleation, in truncated limits. Recent work has examined the decay process in one-dimensional (1D) ferromagnetic Ising spins and superfluids. Here, in this paper, we study nucleation dynamics in 1D antiferromagnetic neutral atom chains with Rydberg interactions, using both numerical simulations and analytic modeling. We apply a staggered local detuning field to generate the metastable and ground states. Our efforts focus on two dynamical regimes: decay and annealing. In the first, we corroborate the phenomenological decay rate scaling and determine the associated parameter range for the decay process; in the second, we uncover and elucidate a procedure to anneal the metastable state from the initial to the final system, with intermediate nucleation events. We further propose experimental protocols to prepare the required states and perform quenches on near-term neutral atom quantum simulators, examining the experimental feasibility of our proposed setup and parameter regime.

97 MATHEMATICS AND COMPUTING↗

SU-E-T-309: Dosimetric Comparison of Simultaneous Integrated Boost Treatment Plan Between Intensity Modulated Radiotherapies (IMRTs), Dual Arc Volumetric Modulated Arc Therapy (DA-VMAT) and Single Arc Volumetric Modulated Arc Therapy (SA-VMAT) for Nasopharyngeal Carcinoma (NPC)

Purpose: To compare the plan quality and performance of Simultaneous Integrated Boost (SIB) Treatment plan between Seven field (7F) and Nine field(9F) Intensity Modulated Radiotherapies and Single Arc (SA) and Dual Arc (DA) Volumetric Modulated Arc Therapy( VMAT). Methods: Retrospective planning study of 16 patients treated in Elekta Synergy Platform (mlci2) by 9F-IMRT were replanned with 7F-IMRT, Single Arc VMAT and Dual Arc VMAT using CMS, Monaco Treatment Planning System (TPS) with Monte Carlo simulation. Target delineation done as per Radiation Therapy Oncology Protocols (RTOG 0225&0615). Dose Prescribed as 70Gy to Planning Target Volumes (PTV70) and 61Gy to PTV61 in 33 fraction as a SIB technique. Conformity Index(CI), Homogeneity Index(HI) were used as analysis parameter for Target Volumes as well as Mean dose and Max dose for Organ at Risk(OAR,s).Treatment Delivery Time(min), Monitor unit per fraction (MU/fraction), Patient specific quality assurance were also analysed. Results: A Poor dose coverage and Conformity index (CI) was observed in PTV70 by 7F-IMRT among other techniques. SA-VMAT achieved poor dose coverage in PTV61. No statistical significance difference observed in OAR,s except Spinal cord (P= 0.03) and Right optic nerve (P=0.03). DA-VMAT achieved superior target coverage, higher CI (P =0.02) and Better HI (P=0.03) for PTV70 other techniques (7F-IMRT/9F-IMRT/SA-VMAT). A better dose spare for Parotid glands and spinal cord were seen in DA-VMAT. The average treatment delivery time were 5.82mins, 6.72mins, 3.24mins, 4.3mins for 7F-IMRT, 9F-IMRT, SA-VMAT and DA-VMAT respectively. Significance difference Observed in MU/fr (P <0.001) and Patient quality assurance pass rate were >95% (Gamma analysis (Γ3mm, 3%). Conclusion: DA-VAMT showed better target dose coverage and achieved better or equal performance in sparing OARs among other techniques. SA-VMAT offered least Treatment Time than other techniques but achieved poor target coverage. DA-VMAT offered shorter delivery time than 7F-IMRT and 9F-IMRT without compromising the plan quality.

60 APPLIED LIFE SCIENCES↗

SU-C-206-07: A Practical Sparse View Ultra-Low Dose CT Acquisition Scheme for PET Attenuation Correction in the Extended Scan Field-Of-View

Purpose: To further reduce CT dose, a practical sparse-view acquisition scheme is proposed to provide the same attenuation estimation as higher dose for PET imaging in the extended scan field-of-view. Methods: CT scans are often used for PET attenuation correction and can be acquired at very low CT radiation dose. Low dose techniques often employ low tube voltage/current accompanied with a smooth filter before backprojection to reduce CT image noise. These techniques can introduce bias in the conversion from HU to attenuation values, especially in the extended CT scan field-of-view (FOV). In this work, we propose an ultra-low dose CT technique for PET attenuation correction based on sparse-view acquisition. That is, instead of an acquisition of full amount of views, only a fraction of views are acquired. We tested this technique on a 64-slice GE CT scanner using multiple phantoms. CT scan FOV truncation completion was performed based on the published water-cylinder extrapolation algorithm. A number of continuous views per rotation: 984 (full), 246, 123, 82 and 62 have been tested, corresponding to a CT dose reduction of none, 4x, 8x, 12x and 16x. We also simulated sparse-view acquisition by skipping views from the fully-acquired view data. Results: FBP reconstruction with Q. AC filter on reduced views in the full extended scan field-of-view possesses similar image quality to the reconstruction on acquired full view data. The results showed a further potential for dose reduction compared to the full acquisition, without sacrificing any significant attenuation support to the PET. Conclusion: With the proposed sparse-view method, one can potential achieve at least 2x more CT dose reduction compared to the current Ultra-Low Dose (ULD) PET/CT protocol. A pre-scan based dose modulation scheme can be combined with the above sparse-view approaches, which can even further reduce the CT scan dose during a PET/CT exam.

60 APPLIED LIFE SCIENCES↗

Publication and Retrieval of Computational Chemical-Physical Data Via the Semantic Web. Final Technical Report

This research showed the feasibility of applying the concepts of the Semantic Web to Computation Chemistry. We have created the first web portal (www.chemsem.com) that allows data created in the calculations of quantum chemistry, and other such chemistry calculations to be placed on the web in a way that makes the data accessible to scientists in a semantic form never before possible. The semantic web nature of the portal allows data to be searched, found, and used as an advance over the usual approach of a relational database. The semantic data on our portal has the nature of a Giant Global Graph (GGG) that can be easily merged with related data and searched globally via a SPARQL Protocol and RDF Query Language (SPARQL) that makes global searches for data easier than with traditional methods. Our Semantic Web Portal requires that the data be understood by a computer and hence defined by an ontology (vocabulary). This ontology is used by the computer in understanding the data. We have created such an ontology for computational chemistry (purl.org/gc) that encapsulates a broad knowledge of the field of computational chemistry. We refer to this ontology as the Gainesville Core. While it is perhaps the first ontology for computational chemistry and is used by our portal, it is only a start of what must be a long multi-partner effort to define computational chemistry. In conjunction with the above efforts we have defined a new potential file standard (Common Standard for eXchange – CSX for computational chemistry data). This CSX file is the precursor of data in the Resource Description Framework (RDF) form that the semantic web requires. Our portal translates CSX files (as well as other computational chemistry data files) into RDF files that are part of the graph database that the semantic web employs. We propose a CSX file as a convenient way to encapsulate computational chemistry data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Studies of Trace Gas Chemical Cycles Using Inverse Methods and Global Chemical Transport Models

We report progress in the first year, and summarize proposed work for the second year of the three-year dynamical-chemical modeling project devoted to: (a) development, testing, and refining of inverse methods for determining regional and global transient source and sink strengths for long lived gases important in ozone depletion and climate forcing, (b) utilization of inverse methods to determine these source/sink strengths using either MATCH (Model for Atmospheric Transport and Chemistry) which is based on analyzed observed wind fields or back-trajectories computed from these wind fields, (c) determination of global (and perhaps regional) average hydroxyl radical concentrations using inverse methods with multiple titrating gases, and (d) computation of the lifetimes and spatially resolved destruction rates of trace gases using 3D models. Important goals include determination of regional source strengths of methane, nitrous oxide, methyl bromide, and other climatically and chemically important biogenic/anthropogenic trace gases and also of halocarbons restricted by the Montreal protocol and its follow-on agreements and hydrohalocarbons now used as alternatives to the restricted halocarbons.

Prinn, Ronald G.↗

Revisiting the West Clearwater Lake Impact Structure, Canada

The West and East Clearwater Lake impact structures are two of the most distinctive and recognizable impact structures on Earth. Known regionally as the "Clearwater Lake Complex", these structures are located in northern Quebec, Canada (56 deg 10 N, 74 deg 20 W) approximately 125 km east of Hudson Bay. The currently accepted diameters are 36 km and 26 km for the West and East structures, respectively. Long thought to represent a rare example of a double impact, recent age dating has called this into question with ages of approximately 286 Ma and approximately 460-470 Ma being proposed for the West and East structures, respectively. Relatively little is known about the East Clearwater Lake structure. There is no surface exposure and what information there is comes from geophysics and two drill cores obtained in the 1960s. In contrast, the West Clearwater Lake structure is relatively well preserved with large ring of islands in the approximately 30 km diameter lake. Much of the work done on West Clearwater stems from field investigations carried out in 1977 driven by the Apollo program, with a focus on the impact melt rocks and other impactites, which are well exposed on the ring of islands. To our knowledge, the Clearwater Lake impact structures have not been the focus of detailed impact geology field investigations since the 1977 expedition and the only geological map that exists is from the 1960s and is at the reconnaissance level. Our knowledge of impact cratering processes have increased substantially since this time, as have the analytical techniques available for samples. This provided the motivation for a joint Canadian-US-UK expedition to the West Clearwater Lake impact structure in August and September 2015, under the auspices of the FINESSE (Field Investigations to Enable Solar System Science and Exploration) project, part of NASA's Solar System Exploration Research Virtual Institute (SSERVI). We focus here on the impactites of the West Clearwater Lake impact structure. Other ongoing studies, also presented at this conference, focus on central uplift formation, the impact-generated hydrothermal system, xxxx and using WCIS as an analog test site for crew studies of sampling protocols].

West Clearwater Lake↗

RoboCount{sup TM} 2020 - A Robotic Non-Destructive Waste Assay System - 19331

A robotic system for non-destructive assay of radioactive waste - RoboCount{sup TM} 2020ab - has been designed, manufactured, and a prototype delivered to a customer. RoboCount{sup TM} 2020 is based on an industrial 6-axis articulating robot platform, combined with a dedicated waste package platform and a high-resolution HPGe gamma spectrometer. The system enables measurement of waste packages including drums (100-l, 200-l, 400-l), crates (up to 1200 x 800 x 800 mm), 1 m{sup 3} flexible intermediate bulk containers (FIBC), and others. Assay type can be freely defined, ranging from currently accepted protocols such as segmented gamma scan (SGS) or integral gamma scan (IGS) to new protocols developed for specific non-cylindrical waste packages, e.g., measurement of FIBCs from all four sides and the top. As a result of the robotic hardware flexibility, reconfiguration of the system for a new task is a matter of software changes only. In addition, while primarily geared towards waste characterization, the system can be configured for free release (clearance) by installing a second detector and field-of-view shielding. The prototype is currently in operation at a NPP site in Europe where it is used for D and D waste characterization in crates and FIBCs. Additional features beyond the basic functionality have been implemented such as an automatic lead collimator change based on measured HPGe detector dead time and an automatic liquid nitrogen refill, performed by the robot via a docking station at predefined time intervals. (Use of electrically cooled HPGe detectors is also possible). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Biofilm monitoring using complex permittivity.

There is strong interest in the detection and monitoring of bio-fouling. Bio-fouling problems are common in numerous water treatments systems, medical and dental apparatus and food processing equipment. Current bio-fouling control protocols are time consuming and costly. New early detection techniques to monitor bio-forming contaminates are means to enhanced efficiency. Understanding the unique dielectric properties of biofilm development, colony forming bacteria and nutrient background will provide a basis to the effectiveness of controlling or preventing biofilm growth. Dielectric spectroscopy measurements provide values of complex permittivity, {var_epsilon}*, of biofilm formation by applying a weak alternating electric field at various frequencies. The dielectric characteristic of the biofilm, {var_epsilon}{prime}, is the real component of {var_epsilon}* and measures the biofilm's unique ability to store energy. Graphically observed dependencies of {var_epsilon}{prime} to frequency indicate dielectric relaxation or dielectric dispersion behaviors that mark the particular stage of progression during the development of biofilms. In contrast, any frequency dependency of the imaginary component, {var_epsilon}{double_prime} the loss factor, is expressed as dielectric losses from the biofilm due to dipole relaxation. The tangent angle of these two component vectors is the ratio of the imaginary component to the real component, {var_epsilon}{double_prime}/{var_epsilon}{prime} and is referred to as the loss angle tangent (tan {delta}) or dielectric loss. Changes in tan {delta} are characteristic of changes in dielectric losses during various developmental stages of the films. Permittivity scans in the above figure are of biofilm growth from P. Fluorescens (10e7 CFU's at the start). Three trends are apparent from these scans, the first being a small drop in the imaginary permittivity over a 7 hours period, best seen in the Cole-Cole plot (a). The second trend is observed two hours after inoculation when the permittivity begins to increase slightly over the next 20 hours, best seen in the shift from 1000 Hz to 5000 Hz in tan {delta} at the high frequencies (c). Because of similar dielectric relaxation properties noted by the comparable size of the semicircles, plot (a), and the height of tan {delta}, plot (c), within the first 29 hours, cell activity levels did not appreciably change. The third trend is observed when the complex permittivity value drops by orders of magnitude between 29 hours and 37 hours, best seen in the log [E] plot (b), and in the drop of the dielectric loss, tan {delta}, to 0. This change in the dielectric properties in the bio environment is nearly independent of all frequencies (c) and dissimilar from the original condition when only bacteria and nutrient was present in the biofilm chambers. The semicircles in plot (a) for this period decreased below the resolution of the graph, implying a large difference in the dielectric behavior of the cells/biofilms consisting of low dielectric losses. We believe these large changes are related to the on-set of biofilms.

36 MATERIALS SCIENCE↗

Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source

Purpose: Historically, treatment of malignant surface lesions has been achieved with linear accelerator based electron beams or superficial x-ray beams. Recent developments in the field of brachytherapy now allow for the treatment of surface lesions with specialized conical applicators placed directly on the lesion. Applicators are available for use with high dose rate (HDR){sup 192}Ir sources, as well as electronic brachytherapy sources. Part I of this paper will discuss the applicators used with electronic brachytherapy sources; Part II will discuss those used with HDR {sup 192}Ir sources. Although the use of these applicators has gained in popularity, the dosimetric characteristics including depth dose and surface dose distributions have not been independently verified. Additionally, there is no recognized method of output verification for quality assurance procedures with applicators like these. Existing dosimetry protocols available from the AAPM bookend the cross-over characteristics of a traditional brachytherapy source (as described by Task Group 43) being implemented as a low-energy superficial x-ray beam (as described by Task Group 61) as observed with the surface applicators of interest. Methods: This work aims to create a cohesive method of output verification that can be used to determine the dose at the treatment surface as part of a quality assurance/commissioning process for surface applicators used with HDR electronic brachytherapy sources (Part I) and{sup 192}Ir sources (Part II). Air-kerma rate measurements for the electronic brachytherapy sources were completed with an Attix Free-Air Chamber, as well as several models of small-volume ionization chambers to obtain an air-kerma rate at the treatment surface for each applicator. Correction factors were calculated using MCNP5 and EGSnrc Monte Carlo codes in order to determine an applicator-specific absorbed dose to water at the treatment surface from the measured air-kerma rate. Additionally, relative dose measurements of the surface dose distributions and characteristic depth dose curves were completed in-phantom. Results: Theoretical dose distributions and depth dose curves were generated for each applicator and agreed well with the measured values. A method of output verification was created that allows users to determine the applicator-specific dose to water at the treatment surface based on a measured air-kerma rate. Conclusions: The novel output verification methods described in this work will reduce uncertainties in dose delivery for treatments with these kinds of surface applicators, ultimately improving patient care.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Versatile Microfluidic Device for Automating Synthetic Biology

New microbes are being engineered that contain the genetic circuitry, metabolic pathways, and other cellular functions required for a wide range of applications such as producing biofuels, biobased chemicals, and pharmaceuticals. Although currently available tools are useful in improving the synthetic biology process, further improvements in physical automation would help to lower the barrier of entry into this field. We present an innovative microfluidic platform for assembling DNA fragments with 10× lower volumes (compared to that of current microfluidic platforms) and with integrated region-specific temperature control and on-chip transformation. Integration of these steps minimizes the loss of reagents and products compared to that with conventional methods, which require multiple pipetting steps. For assembling DNA fragments, we implemented three commonly used DNA assembly protocols on our microfluidic device: Golden Gate assembly, Gibson assembly, and yeast assembly (i.e., TAR cloning, DNA Assembler). Here, we demonstrate the utility of these methods by assembling two combinatorial libraries of 16 plasmids each. Each DNA plasmid is transformed into Escherichia coli or Saccharomyces cerevisiae using on-chip electroporation and further sequenced to verify the assembly. Lastly, we anticipate that this platform will enable new research that can integrate this automated microfluidic platform to generate large combinatorial libraries of plasmids and will help to expedite the overall synthetic biology process.

59 BASIC BIOLOGICAL SCIENCES↗

Deterministic generation of a three-dimensional entangled state via quantum Zeno dynamics

A scheme is proposed for the generation of a three-dimensional entangled state for two atoms trapped in a cavity via quantum Zeno dynamics. Because the scheme is based on the resonant interaction, the time required to produce entanglement is very short compared with the dispersive protocols. We show that the resulting effective dynamics allows for the creation of robust qutrit-qutrit entanglement. The influence of various decoherence processes such as spontaneous emission and photon loss on the fidelity of the entangled state is investigated. Numerical results show that the scheme is robust against the cavity decay since the evolution of the system is restricted to a subspace with null-excitation cavity fields. Furthermore, the present scheme has been generalized to realize N-dimensional entanglement for two atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Information-Guided Dynamic Nuclear Polarization

A spin ensemble in thermal equilibrium continuously undergoes random fluctuations analogous to those observed in Brownian motion, a process known as spin noise. Here, we investigate the dynamics of a system comprising a spin-1 paramagnetic center and a hyperfine-coupled spin-1/2 nucleus in the vicinity of a level crossing. We theoretically show that nuclear spins polarize efficiently under the combined action of thermal fluctuations and a closed-loop feedback protocol. The latter articulates periodic observations of the electronic magnetization and radio-frequency pulses connecting hybrid states with opposite nuclear spin alignment. Since nuclear polarization emerges from electronic spin fluctuations, not spin order, this microwave-free technique generically benefits from warmer, not colder, operation temperatures. Furthermore, because the spin dynamics at play near a level crossing is rather insensitive to the absolute value of the magnetic field, our work promises opportunities for high-field dynamic nuclear polarization, which is difficult to attain through present methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Directional and polarimetric effects in the optical domain

Papers focused on land surface, atmospheric, and ocean properties are reported. Specific comments pertaining to polarization, models and inversion, and measurements, are given. Recommendations are: continued research into the application potential of the BRDF (Bidirectional Reflectance Distribution Function) and polarization properties of ground surface and atmospheric targets; three dimensional models, which account for the statistical behavior of remotely sensed data, should be extended and inverted in order to support analysis of data potentially covering rolling terrain such that pixels represent heterogeneous mixtures of surface cover types and project ground footprints with sizes between 10 to 6 km, the ground pixel sizes of planned future sensors; available reflectance models should be further validated by means of multi dimensional (directional, spectral, temporal) field data and existing models should be intercompared in more depth to evaluate their performance and limitations; existing methods for model inversion should be validated in more depth in order to quantify the practical limitations and the expected accuracy of the parameters retrieved and new approaches should be developed based upon apriori knowledge of plant canopy development and spectral BRDF properties; there is a need to establish a protocol of validation and intercomparison of the indices and compositing techniques which have been proposed during these last years.

Vanderbilt, V. C.↗

Integrated Quantum-Classical Protocol for the Realistic Description of Solvated Multinuclear Mixed-Valence Transition-Metal Complexes and Their Solvatochromic Properties

Linear cyanide-bridged polymetallic complexes, which undergo photoinduced metal-to-metal charge transfer, represent prototypical systems for studying long-range electron-transfer reactions and understanding the role played by specific solute–solvent interactions in modulating the excited-state dynamics. Here, to tackle this problem, while achieving a statistically meaningful description of the solvent and of its relaxation, one needs a computational approach capable of handling large polynuclear transition-metal complexes, both in their ground and excited states, as well as the ability to follow their dynamics in several environments up to nanosecond time scales. Here, we present a mixed quantum classical approach, which combines large-scale molecular dynamics (MD) simulations based on an accurate quantum mechanically derived force field (QMD-FF) and self-consistent QMD polarized point charges, with IR and UV–vis spectral calculations to model the solvation dynamics and optical properties of a cyano-bridged trinuclear mixed-valence compound (trans-[(NC) 5 Fe III (μ-CN)Ru II (pyridine) 4 (μ-NC)Fe III (CN) 5 ] 4– ). We demonstrate the reliability of the QMD-FF/MD approach in sampling the solute conformational space and capturing the local solute–solvent interactions by comparing the results with higher-level quantum mechanics/molecular mechanics (QM/MM) MD reference data. The IR spectra calculated along the classical MD trajectories in different solvents correctly predict the red shift of the CN stretching band in the aprotic medium (acetonitrile) and the subtle differences measured in water and methanol, respectively. By explicitly including the solvent molecules around the cyanide ligands and calculating the thermal averaged absorption spectra using time-dependent density functional theory calculations within the Tamm–Dancoff approximation, the experimental solvatochromic shift is quantitatively reproduced going from water to methanol, while it is overestimated for acetonitrile. This discrepancy can likely be traced back to the lack of important dispersion interactions between the solvent cyano groups and the pyridine substituents in our micro solvation model. The proposed protocol is applied to the ground state in water, methanol, and acetonitrile and can be flexibly generalized to study excited-state nonequilibrium solvation dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ceci N’est Pas Une Bombe: Lessons from a Field Experiment Using Neutron and Gamma Measurements to Confirm the Absence of Nuclear Weapons

In March 2023, the UN Institute for Disarmament Research held a verification experiment that included a mockup onsite inspection at a former military facility in the municipality of Menzingen, Switzerland. The experiment included a visit to the site by an inspection team, accompanied by the host team. Among other activities, radiation measurements were used to confirm the non-nuclear nature of selected items stored onsite. In this paper, we discuss the neutron and gamma measurement systems used during the experiment and the inspection protocols followed to confirm the absence of nuclear weapons. Furthermore, results from the experiment and a laboratory reproduction are presented, before concluding with lessons learned for how absence-confirmation measurements can help support verification of future arms control agreements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗