Search NASA⌕ Search

SEARCH · Search NASA

Results for “functional regression”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

High Resolution ECG for Evaluation of Heart Function During Exposure to Subacute Hypobaric Hypoxia

High altitude climbing presents a wide spectrum of health risks, including exposure to hypobaric hypoxia. Risks are also typically exacerbated by the difficulty in appropriately monitoring for early signs of organ dysfunction in remote areas. We investigated whether high resolution advanced ECG analysis might be helpful as a non-invasive and easy-to-use tool (e.g., instead of Doppler echocardiography) for evaluating early signs of heart overload in hypobaric hypoxia. Nine non-acclimatized healthy trained alpine rescuers (age 43.7 plus or minus 7.3 years) climbed in four days to the altitude of 4,200 m on Mount Ararat. Five-minute high-resolution 12-lead electrocardiograms (ECGs) were recorded (Cardiosoft) in each subject at rest in the supine position on different days but at the same time of day at four different altitudes: 400 m (reference altitude), 1,700 m, 3,200 m and 4,200 m. Changes in conventional and advanced resting ECG parameters, including in beat-to-beat QT and RR variability, waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG was estimated by calculation of the regression coefficients in independent linear regression models. A p-value of less than 0.05 was adopted as statistically significant. As expected, the RR interval and its variability both decreased with increasing altitude, with trends k = -96 ms/1000 m with p = 0.000 and k = -9 ms/1000 m with p = 0.001, respectively. Significant changes were found in P-wave amplitude, which nearly doubled from the lowest to the highest altitude (k = 41.6 microvolt/1000 m with p = 0.000), and nearly significant changes in P-wave duration (k = 2.9 ms/1000 m with p = 0.059). Changes were less significant or non-significant in other studied parameters including those of waveform complexity, signal-averaged, high-frequency and spatial/spatiotemporal ECG. High resolution ECG analysis, particularly of the P wave, shows promise as a tool for monitoring early changes in heart function due to exposure to high altitude.

Zupet, Petra↗

Spirometric traits show quantile-dependent heritability, which may contribute to their gene-environment interactions with smoking and pollution

Background: “Quantile-dependent expressivity” refers to a genetic effect that is dependent upon whether the phenotype (e.g., spirometric data) is high or low relative to its population distribution. Forced vital capacity (FVC), forced expiratory volume in 1 second (FEV 1 ), and the FEV 1 /FVC ratio are moderately heritable spirometric traits. The aim of the analyses is to test whether their heritability (h 2 ) is constant over all quantiles of their distribution. Methods: Quantile regression was applied to the mean age, sex, height and smoking-adjusted spirometric data over multiple visits in 9,993 offspring-parent pairs and 1,930 sibships from the Framingham Heart Study to obtain robust estimates of offspring-parent (β OP ), offspring-midparent (β OM ), and full-sib regression slopes (β FS ). Nonparametric significance levels were obtained from 1,000 bootstrap samples. β OP s were used as simple indicators of quantile-specific heritability (i.e.,h 2 = 2β OP /(1+r spouse ), where r spouse was the correlation between spouses). Results: β OP ± standard error (SE) decreased by 0.0009 ± 0.0003 (P = 0.003) with every one-percent increment in the population distribution of FEV 1 /FVC, i.e., β OP ± SE were: 0.182 ± 0.031, 0.152 ± 0.015; 0.136 ± 0.011; 0.121 ± 0.013; and 0.099 ± 0.013 at the 10th, 25th, 50th, 75th, and 90th percentiles of the FEV 1 /FVC distribution, respectively. These correspond to h 2 ± SEs of 0.350 ± 0.060 at the 10th, 0.292 ± 0.029 at the 25th, 0.262 ± 0.020 at the 50th, 0.234 ± 0.025 at the 75th, and 0.191 ± 0.025 at the 90th percentiles of the FEV 1 /FVC ratio. Maximum mid-expiratory flow (MMEF) h 2 ± SEs increased 0.0025 ± 0.0007 (P = 0.0004) with every one-percent increment in its distribution, i.e.: 0.467 ± 0.046, 0.467 ± 0.033, 0.554 ± 0.038, 0.615 ± 0.042, and 0.675 ± 0.060 at the 10th, 25th, 50th, 75th, and 90th percentiles of its distribution. This was due to forced expiratory flow at 75% of FVC (FEF75%), whose quantile-specific h 2 increased an average of 0.0042 ± 0.0008 for every one-percent increment in its distribution. It is speculated that previously reported gene-environment interactions may be partially attributable to quantile-specific h 2 , i.e., greater heritability in individuals with lower FEV 1 /FVC due to smoking or airborne particles exposure vs. nonsmoking, unexposed individuals. Conclusion: Heritabilities of FEV 1 /FVC, MMEF, and FEF75% from quantile-regression of offspring-parent and sibling spirometric data suggest their quantile-dependent expressivity.

59 BASIC BIOLOGICAL SCIENCES↗

Lack of anti-tumor activity with the β-catenin expression inhibitor EZN-3892 in the C57BL/6J Min/+ model of intestinal carcinogenesis

Highlights: • Wnt/β-catenin signaling is aberrantly activated in most colorectal cancers. • Locked nucleic acid (LNA)-based antisense is a novel tool for cancer therapy. • β-Catenin inhibition was observed in mature intestinal tissue of LNA-treated mice. • Further investigation of Wnt/β-catenin targeted therapies is warranted. - Abstract: Background: Previously, we showed that short-term inhibition of β-catenin expression and reversal of aberrant β-catenin subcellular localization by the selective COX-2 inhibitor celecoxib is associated with adenoma regression in the C57BL/6J Min/+ mouse. Conversly, long-term administration resulted in tumor resistance, leading us to investigate alternative methods for selective β-catenin chemoprevention. In this study, we hypothesized that disruption of β-catenin expression by EZN-3892, a selective locked nucleic acid (LNA)-based β-catenin inhibitor, would counteract the tumorigenic effect of Apc loss in Min/+ adenomas while preserving normal intestinal function. Materials and methods: C57BL/6J Apc{sup +/+} wild-type (WT) and Min/+ mice were treated with the maximum tolerated dose (MTD) of EZN-3892 (30 mg/kg). Drug effect on tumor numbers, β-catenin protein expression, and nuclear β-catenin localization were determined. Results: Although the tumor phenotype and β-catenin nuclear localization in Min/+ mice did not change following drug administration, we observed a decrease in β-catenin expression levels in the mature intestinal tissue of treated Min/+ and WT mice, providing proof of principle regarding successful delivery of the LNA-based antisense vehicle. Higher doses of EZN-3892 resulted in fatal outcomes in Min/+ mice, likely due to β-catenin ablation in the intestinal tissue and loss of function. Conclusions: Our data support the critical role of Wnt/β-catenin signaling in maintaining intestinal homeostasis and highlight the challenges of effective drug delivery to target disease without permanent toxicity to normal cellular function.

60 APPLIED LIFE SCIENCES↗

SU-D-BRB-02: Patient-Specific Rectal Toxicity Predictor Based Plan Quality Control for Prostate Stereotactic Body Radiation Therapy (SBRT)

Purpose: To develop a patient-specific rectal toxicity predictor guided plan quality control tool for prostate SBRT plans. Methods: For prostate SBRT cases, four segments of rectal walls including peri-prostatic anterior rectal wall, peri-prostatic lateral rectal walls, peri-prostatic posterior rectal wall and rectum superior to prostate are identified as organs at risk and the circumference of rectal wall receiving more than 39 Gy (CRW39) and 24 Gy (CRW24) are rectal toxicity predictors. In this new geometry-dosimetry model, a patient geometry descriptor, differential circumference of rectal wall (dCRW) is used as model input geometry parameters and plan dosimetric endpoints CRW39 and CRW24 are output dosimetric parameters. Linear models are built to correlate dCRW to both CRW39 and CRW24 and established with both a linear regression method and a modified bagging ensemble machine learning method. 27 SBRT prostate cases are retrospectively studied from a dose-escalated clinical trial research. 20 prescribed 50 Gy SBRT cases are recruited to train the model and the other rescaled 7 cases are used to evaluated model feasibility and accuracy. Results: Each solved linear coefficient sequence related to CRW39 or CRW24 is a one-dimensional decreasing function of the distance from the PTV boundary, indicating that the different locations of each rectal circumference have different contributions to each particular dosimetric endpoint. The fitting errors for those trained 20 prostate SBRT cases are small with mean values of 2.39%, 2.45% relative to the endpoint values for SBRT rectal toxicity predictor CRW39 and CRW24 respectively. 1 out of 7 evaluation plans is identified as poor quality plan. After re-planning, the CRW39 and CRW24 can be reduced by 3.34% and 3%, without sacrificing PTV coverage. Conclusion: The proposed patient geometry-plan toxicity predictor model for SBRT plans can be successfully applied to plan quality control for prostate SBRT cases.

60 APPLIED LIFE SCIENCES↗

Association Between Anticholinergic Medication Use and Cognition, Brain Metabolism, and Brain Atrophy in Cognitively Normal Older Adults

Importance of this Paper: The use of anticholinergic (AC) medication is linked to cognitive impairment and an increased risk of dementia. To our knowledge, this is the first study to investigate the association between AC medication use and neuroimaging biomarkers of brain metabolism and atrophy as a proxy for understanding the underlying biology of the clinical effects of AC medications. Objective: To assess the association between AC medication use and cognition, glucose metabolism, and brain atrophy in cognitively normal older adults from the Alzheimer’s Disease Neuroimaging Initiative (ADNI) and the Indiana Memory and Aging Study (IMAS). Design, Setting, and Participants: The ADNI and IMAS are longitudinal studies with cognitive, neuroimaging, and other data collected at regular intervals in clinical and academic research settings. For the participants in the ADNI, visits are repeated 3, 6, and 12 months after the baseline visit and then annually. For the participants in the IMAS, visits are repeated every 18 months after the baseline visit (402 cognitively normal older adults in the ADNI and 49 cognitively normal older adults in the IMAS were included in the present analysis). Participants were either taking (hereafter referred to as the AC + participants [52 from the ADNI and 8 from the IMAS]) or not taking (hereafter referred to as the AC - participants [350 from the ADNI and 41 from the IMAS]) at least 1 medication with medium or high AC activity. Data analysis for this study was performed in November 2015. Main Outcomes and Measures: Cognitive scores, mean fludeoxyglucose F 18 standardized uptake value ratio (participants from the ADNI only), and brain atrophy measures from structural magnetic resonance imaging were compared between AC + participants and AC - participants after adjusting for potential confounders. The total AC burden score was calculated and was related to target measures. The association of AC use and longitudinal clinical decline (mean [SD] follow-up period, 32.1 [24.7] months [range, 6-108 months]) was examined using Cox regression. Results: The 52 AC + participants (mean [SD] age, 73.3 [6.6] years) from the ADNI showed lower mean scores on Weschler Memory Scale–Revised Logical Memory Immediate Recall (raw mean scores: 13.27 for AC + participants and 14.16 for AC - participants; P = .04) and the Trail Making Test Part B (raw mean scores: 97.85 seconds for AC + participants and 82.61 seconds for AC - participants; P = .04) and a lower executive function composite score (raw mean scores: 0.58 for AC + participants and 0.78 for AC - participants; P = .04) than the 350 AC - participants (mean [SD] age, 73.3 [5.8] years) from the ADNI. Reduced total cortical volume and temporal lobe cortical thickness and greater lateral ventricle and inferior lateral ventricle volumes were seen in the AC + participants relative to the AC - participants. Conclusions and Relevance of this Paper: The use of AC medication was associated with increased brain atrophy and dysfunction and clinical decline. Thus and finally, use of AC medication among older adults should likely be discouraged if alternative therapies are available.

60 APPLIED LIFE SCIENCES↗

Dietary B group vitamin intake and the bladder cancer risk: a pooled analysis of prospective cohort studies

Abstract Purpose Diet may play an essential role in the aetiology of bladder cancer (BC). The B group complex vitamins involve diverse biological functions that could be influential in cancer prevention. The aim of the present study was to investigate the association between various components of the B group vitamin complex and BC risk. Methods Dietary data were pooled from four cohort studies. Food item intake was converted to daily intakes of B group vitamins and pooled multivariate hazard ratios (HRs), with corresponding 95% confidence intervals (CIs), were obtained using Cox-regression models. Dose–response relationships were examined using a nonparametric test for trend. Results In total, 2915 BC cases and 530,012 non-cases were included in the analyses. The present study showed an increased BC risk for moderate intake of vitamin B1 (HR B1 : 1.13, 95% CI: 1.00–1.20). In men, moderate intake of the vitamins B1, B2, energy-related vitamins and high intake of vitamin B1 were associated with an increased BC risk (HR (95% CI): 1.13 (1.02–1.26), 1.14 (1.02–1.26), 1.13 (1.02–1.26; 1.13 (1.02–1.26), respectively). In women, high intake of all vitamins and vitamin combinations, except for the entire complex, showed an inverse association (HR (95% CI): 0.80 (0.67–0.97), 0.83 (0.70–1.00); 0.77 (0.63–0.93), 0.73 (0.61–0.88), 0.82 (0.68–0.99), 0.79 (0.66–0.95), 0.80 (0.66–0.96), 0.74 (0.62–0.89), 0.76 (0.63–0.92), respectively). Dose–response analyses showed an increased BC risk for higher intake of vitamin B1 and B12. Conclusion Our findings highlight the importance of future research on the food sources of B group vitamins in the context of the overall and sex-stratified diet.

60 APPLIED LIFE SCIENCES↗

PCAfold 2.0—Novel tools and algorithms for low-dimensional manifold assessment and optimization

We describe an update to our open-source Python package, PCAfold, designed to help researchers generate, analyze and improve low-dimensional data manifolds. In the current version, PCAfold 2.0, we introduce novel tools and algorithms for assessing and optimizing low-dimensional manifolds. This includes a method that generates a “map” of local feature sizes that can help pinpoint researchers to problematic regions on a manifold. We introduce a novel cost function that characterizes the quality of a manifold topology with a single number. We develop two algorithms for feature selection based on principal component analysis (PCA) that use the cost function as an objective function to minimize. We introduce a quantity of interest (QoI)-aware dimensionality reduction strategy where data projections are computed using an artificial neural network and are directly optimized towards representing various projection-independent and projection-dependent QoIs. We also introduce an implementation of partition of unity networks (POUnets) for efficient reconstruction of QoIs from low-dimensional manifolds based on combining neural network classification with localized polynomial regression. Our software can be broadly applicable in all domains of science and engineering that aim to reduce data dimensionality, as well as in the fundamental research on representation learning.

97 MATHEMATICS AND COMPUTING↗

Software aspects of the Geant4 validation repository

The Geant4, GeantV and GENIE collaborations regularly perform validation and regression tests for simulation results. DoSSiER (Database of Scientic Simulation and Experimental Results) is being developed as a central repository to store the simulation results as well as the experimental data used for validation. DoSSiER is easily accessible via a web application. In addition, a web service allows for programmatic access to the repository to extract records in JSON or XML exchange formats. In this article, we describe the functionality and the current status of various components of DoSSiER as well as the technology choices we made.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Southern Photometric Quasar Catalog from the Dark Energy Survey Data Release 2

We present a catalog of 1.4 million photometrically selected quasar candidates in the southern hemisphere over the ~5000 deg 2 Dark Energy Survey (DES) wide survey area. We combine optical photometry from the DES second data release (DR2) with available near-infrared (NIR) and the all-sky unWISE mid-infrared photometry in the selection. We build models of quasars, galaxies, and stars with multivariate skew-t distributions in the multidimensional space of relative fluxes as functions of redshift (or color for stars) and magnitude. Our selection algorithm assigns probabilities for quasars, galaxies, and stars and simultaneously calculates photometric redshifts (photo-z) for quasar and galaxy candidates. Benchmarking on spectroscopically confirmed objects, we successfully classify (with photometry) 94.7% of quasars, 99.3% of galaxies, and 96.3% of stars when all IR bands (NIR YJHK and WISE W1W2) are available. The classification and photo-z regression success rates decrease when fewer bands are available. Our quasar (galaxy) photo-z quality, defined as the fraction of objects with the difference between the photo-z z p and the spectroscopic redshift z s , |Δz| ≡ |z s - z p |/(1 + z s ) ≤ 0.1, is 92.2% (98.1%) when all IR bands are available, decreasing to 72.2% (90.0%) using optical DES data only. Our photometric quasar catalog achieves an estimated completeness of 89% and purity of 79% at r < 21.5 (0.68 million quasar candidates), with reduced completeness and purity at 21.5 < r ≲ 24. Among the 1.4 million quasar candidates, 87,857 have existing spectra, and 84,978 (96.7%) of them are spectroscopically confirmed quasars. Finally, we provide quasar, galaxy, and star probabilities for all (0.69 billion) photometric sources in the DES DR2 coadded photometric catalog.

79 ASTRONOMY AND ASTROPHYSICS↗

Galactic cosmic radiation model and its applications

A model for the differential energy spectra of galactic cosmic radiation as a function of solar activity is described. It is based on the standard diffusion-convection theory of solar modulation. Estimates of the modulation potential based on fitting this theory to observed spectral measurements from 1954 to 1989 are correlated to the Climax neutron counting rates and to the sunspot numbers at earlier times taking into account the polarity of the interplanetary magnetic field at the time of observations. These regression lines then provide a method for predicting the modulation at later times. The results of this model are quantitatively compared to a similar Moscow State University (MSU) model. These model cosmic ray spectra are used to predict the linear energy transfer spectra, differential energy spectra of light (charge less than or = 2) ions, and single event upsets rates in memeory devices. These calculations are compared to observations made aboard the Space Shuttle.

Badhwar, G. D.↗

A Vehicle Management End-to-End Testing and Analysis Platform for Validation of Mission and Fault Management Algorithms to Reduce Risk for NASAs Space Launch System

The engineering development of the National Aeronautics and Space Administration's (NASA) new Space Launch System (SLS) requires cross discipline teams with extensive knowledge of launch vehicle subsystems, information theory, and autonomous algorithms dealing with all operations from pre-launch through on orbit operations. The nominal and off-nominal characteristics of SLS's elements and subsystems must be understood and matched with the autonomous algorithm monitoring and mitigation capabilities for accurate control and response to abnormal conditions throughout all vehicle mission flight phases, including precipitating safing actions and crew aborts. This presents a large and complex systems engineering challenge, which is being addressed in part by focusing on the specific subsystems involved in the handling of off-nominal mission and fault tolerance with response management. Using traditional model-based system and software engineering design principles from the Unified Modeling Language (UML) and Systems Modeling Language (SysML), the Mission and Fault Management (M&FM) algorithms for the vehicle are crafted and vetted in Integrated Development Teams (IDTs) composed of multiple development disciplines such as Systems Engineering (SE), Flight Software (FSW), Safety and Mission Assurance (S&MA) and the major subsystems and vehicle elements such as Main Propulsion Systems (MPS), boosters, avionics, Guidance, Navigation, and Control (GNC), Thrust Vector Control (TVC), and liquid engines. These model-based algorithms and their development lifecycle from inception through FSW certification are an important focus of SLS's development effort to further ensure reliable detection and response to off-nominal vehicle states during all phases of vehicle operation from pre-launch through end of flight. To test and validate these M&FM algorithms a dedicated test-bed was developed for full Vehicle Management End-to-End Testing (VMET). For addressing fault management (FM) early in the development lifecycle for the SLS program, NASA formed the M&FM team as part of the Integrated Systems Health Management and Automation Branch under the Spacecraft Vehicle Systems Department at the Marshall Space Flight Center (MSFC). To support the development of the FM algorithms, the VMET developed by the M&FM team provides the ability to integrate the algorithms, perform test cases, and integrate vendor-supplied physics-based launch vehicle (LV) subsystem models. Additionally, the team has developed processes for implementing and validating the M&FM algorithms for concept validation and risk reduction. The flexibility of the VMET capabilities enables thorough testing of the M&FM algorithms by providing configurable suites of both nominal and off-nominal test cases to validate the developed algorithms utilizing actual subsystem models such as MPS, GNC, and others. One of the principal functions of VMET is to validate the M&FM algorithms and substantiate them with performance baselines for each of the target vehicle subsystems in an independent platform exterior to the flight software test and validation processes. In any software development process there is inherent risk in the interpretation and implementation of concepts from requirements and test cases into flight software compounded with potential human errors throughout the development and regression testing lifecycle. Risk reduction is addressed by the M&FM group but in particular by the Analysis Team working with other organizations such as S&MA, Structures and Environments, GNC, Orion, Crew Office, Flight Operations, and Ground Operations by assessing performance of the M&FM algorithms in terms of their ability to reduce Loss of Mission (LOM) and Loss of Crew (LOC) probabilities. In addition, through state machine and diagnostic modeling, analysis efforts investigate a broader suite of failure effects and associated detection and responses to be tested in VMET to ensure reliable failure detection, and confirm responses do not create additional risks or cause undesired states through interactive dynamic effects with other algorithms and systems. VMET further contributes to risk reduction by prototyping and exercising the M&FM algorithms early in their implementation and without any inherent hindrances such as meeting FSW processor scheduling constraints due to their target platform - the ARINC 6535-partitioned Operating System, resource limitations, and other factors related to integration with other subsystems not directly involved with M&FM such as telemetry packing and processing. The baseline plan for use of VMET encompasses testing the original M&FM algorithms coded in the same C++ language and state machine architectural concepts as that used by FSW. This enables the development of performance standards and test cases to characterize the M&FM algorithms and sets a benchmark from which to measure their effectiveness and performance in the exterior FSW development and test processes. This paper is outlined in a systematic fashion analogous to a lifecycle process flow for engineering development of algorithms into software and testing. Section I describes the NASA SLS M&FM context, presenting the current infrastructure, leading principles, methods, and participants. Section II defines the testing philosophy of the M&FM algorithms as related to VMET followed by section III, which presents the modeling methods of the algorithms to be tested and validated in VMET. Its details are then further presented in section IV followed by Section V presenting integration, test status, and state analysis. Finally, section VI addresses the summary and forward directions followed by the appendices presenting relevant information on terminology and documentation.

Trevino, Luis↗

Improving Adhesive Bondline Time of Flight Predictions During Autoclave Cure Utilizing Machine Learning

Composite materials are increasingly being used in aerospace applications due to their superior strength-to-weight ratio compared to commonly used metals. A current limitation to widespread adoption is the certification of adhesively bonded joints. One approach to improving adhesive bonding in composites is accurately measuring the thickness of adhesive bondlines in composite laminates. Precise bondline thickness control is essential for aerospace applications where adhesive layer thickness directly affects joint fracture properties and structural performance. This study focused on implementing machine learning techniques to determine the ultrasonic time of flight (directly correlated to thickness) in adhesive bondlines throughout autoclave cure cycles. A high-temperature (use up to 180°C) ultrasonic scanning system was deployed in an autoclave to provide time of flight data through composite panels. Three experiments were conducted on the curing of 305 mm × 305 mm unidirectional composite panels. In the first experiment, a piecewise function was fit for the temperature correction factor to account for changing autoclave temperatures. Due to deficiencies in the first calibration experiment, a second experiment was run, and the results were used to train a machine learning model. The revised experiment, in combination with the machine learning model, significantly increased the accuracy of the bondline time of flight predictions (~14% error reduced to <1%). Data was processed using the Regression Learner Application in MATLAB®, with a Support Vector Machine selected for the model. The result was a machine learning algorithm capable of reliably quantifying ultrasonic time of flight through adhesive bondlines. The third experiment provided independent test data for the machine learning model, demonstrating that the model produces accurate predictions from data beyond its training set.

Machine Learning↗

Decline in Tested and Self-Reported Cognitive Functioning After Prophylactic Cranial Irradiation for Lung Cancer: Pooled Secondary Analysis of Radiation Therapy Oncology Group Randomized Trials 0212 and 0214

Purpose: To assess the impact of prophylactic cranial irradiation (PCI) on self-reported cognitive functioning (SRCF), a functional scale on the European Organization for Research and Treatment of Cancer Core Quality of Life Questionnaire (EORTC QLQ-C30). Methods and Materials: Radiation Therapy Oncology Group (RTOG) protocol 0214 randomized patients with locally advanced non-small cell lung cancer to PCI or observation; RTOG 0212 randomized patients with limited-disease small cell lung cancer to high- or standard-dose PCI. In both trials, Hopkins Verbal Learning Test (HVLT)-Recall and -Delayed Recall and SRCF were assessed at baseline (after locoregional therapy but before PCI or observation) and at 6 and 12 months. Patients developing brain relapse before follow-up evaluation were excluded. Decline was defined using the reliable change index method and correlated with receipt of PCI versus observation using logistic regression modeling. Fisher's exact test correlated decline in SRCF with HVLT decline. Results: Of the eligible patients pooled from RTOG 0212 and RTOG 0214, 410 (93%) receiving PCI and 173 (96%) undergoing observation completed baseline HVLT or EORTC QLQ-C30 testing and were included in this analysis. Prophylactic cranial irradiation was associated with a higher risk of decline in SRCF at 6 months (odds ratio 3.60, 95% confidence interval 2.34-6.37, P<.0001) and 12 months (odds ratio 3.44, 95% confidence interval 1.84-6.44, P<.0001). Decline on HVLT-Recall at 6 and 12 months was also associated with PCI (P=.002 and P=.002, respectively) but was not closely correlated with decline in SRCF at the same time points (P=.05 and P=.86, respectively). Conclusions: In lung cancer patients who do not develop brain relapse, PCI is associated with decline in HVLT-tested and self-reported cognitive functioning. Decline in HVLT and decline in SRCF are not closely correlated, suggesting that they may represent distinct elements of the cognitive spectrum.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Jensen–Shannon divergence based novel loss functions for Bayesian neural networks

Bayesian neural networks (BNNs) are state-of-the-art machine learning methods that can naturally regularize and systematically quantify uncertainties using their stochastic parameters. Kullback–Leibler (KL) divergence-based variational inference used in BNNs suffer from unstable optimization and challenges in approximating light-tailed posteriors due to the unbounded nature of the KL divergence. To resolve these issues, we formulate a novel loss function for BNNs based on a new modification to the generalized Jensen–Shannon (JS) divergence, which is bounded. In addition, we propose a Geometric JS divergence-based loss, which is computationally efficient since it can be evaluated analytically. We found that the JS divergence-based variational inference is intractable, and hence employed a constrained optimization framework to formulate these losses. Our theoretical analysis and empirical experiments on multiple regression and classification data sets suggest that the proposed losses perform better than the KL divergence-based loss, especially when the data sets are noisy or biased. Specifically, there are approximately 5% and 8% improvements in accuracy for a noise-added CIFAR-10 dataset and a regression dataset, respectively. There is about 13% reduction in false negative predictions of a biased histopathology dataset. Additionally, we quantify and compare the uncertainty metrics for the regression and classification tasks.

97 MATHEMATICS AND COMPUTING↗

Experimental demonstration of a data-driven control system for subcritical nuclear facility

Here this paper presents an experimental demonstration of a data-driven control system (DCS) designed for the MIT Graphite Exponential Pile (MGEP). The DCS aims to regulate the neutron flux profile such that symmetry is preserved. Neutron flux perturbations are introduced into the MGEP to test the DCS's capabilities by the movement of an initiating control rod (ICR). To realize this functionality, a control system that relies on an artificial neural network (ANN) was developed, and then demonstrated on the MGEP. A Helium-3 ( 3 He) neutron detector and dual control rods, including their moving mechanisms, were fabricated. The perturbed flux profile was monitored by the moving neutron detector. The prediction accuracy of the neural network (NN) was examined and the DCS response was presented. Our results show that neural network regression model trained by experimental data can achieve a prediction error of less than 2.5 cm with a 95% confidence interval. The demonstration experiment also shows that a perturbation of the ICR can be captured by the control system and flux symmetry can be maintained within 1% after the response of the responding control rod (RCR).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Conditional diffusion machine-learning framework for mapping valence electron distribution from convergent beam electron diffraction

Quantitative convergent beam electron diffraction (CBED) enables determination of aspherical valence electron distributions through refinement of low-order structure factors, which are highly sensitive to chemical bonding and charge density variations. However, conventional quantitative CBED (QCBED) requires solving a highly nonlinear inverse problem with many coupled parameters, and computationally intensive dynamical diffraction calculations, making it time-consuming and difficult to apply to complex systems. More broadly, reconstructing charge density and orbital electron distribution from diffraction data has long been a central challenge in both x-ray and electron crystallography. Here, in this study, we introduce an artificial-intelligence (AI)-based framework that replaces traditional refinement with a data-driven inverse solver. Using a large synthetic CBED dataset generated by Bloch-wave simulations, we train a conditional diffusion model to directly infer crystal structural parameters and multipole density formalism parameters, and hence valence electron distributions, from CBED patterns alone. By learning from forward simulations across realistic parameter space, the model effectively solves the inverse problem. Compared with direct regression approaches, the diffusion-based framework provides posterior parameter distributions for rigorous uncertainty quantification while preserving quantitative fidelity and reducing analysis time by orders of magnitude. By eliminating the need for external single-crystal x-ray diffraction data and complex nonlinear refinement, this approach enables practical, high-throughput, and in situ quantitative CBED, enabling real-time mapping of valence electron distributions and their correlation with functional responses in quantum and energy materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Generative Ensemble Regression: Learning Particle Dynamics from Observations of Ensembles with Physics-informed Deep Generative Models

Here, we propose a new method for inferring the governing stochastic ordinary differential equations (SODEs) by observing particle ensembles at discrete and sparse time instants, i.e., multiple “snapshots.” Particle coordinates at a single time instant, possibly noisy or truncated, are recorded in each snapshot but are unpaired across the snapshots. By training a physics-informed generative model that generates “fake” sample paths, we aim to fit the observed particle ensemble distributions with a curve in the probability measure space, which is induced from the inferred particle dynamics. We employ different metrics to quantify the differences between distributions, e.g., the sliced Wasserstein distances and the adversarial losses in generative adversarial networks. We refer to this method as generative “ensemble-regression” (GER), in analogy to the classic “point-regression,” where we infer the dynamics by performing regression in the Euclidean space. We illustrate the GER by learning the drift and diffusion terms of particle ensembles governed by SODEs with Brownian motions and Lévy processes up to 100 dimensions. We also discuss how to treat cases with noisy or truncated observations. Apart from systems consisting of independent particles, we also tackle nonlocal interacting particle systems with unknown interaction potential parameters by constructing a physics-informed loss function. Finally, we investigate scenarios of paired observations and discuss how to reduce the dimensionality in such cases by proving a convergence theorem that provides theoretical support.

97 MATHEMATICS AND COMPUTING↗

Framework for a space shuttle main engine health monitoring system

A framework developed for a health management system (HMS) which is directed at improving the safety of operation of the Space Shuttle Main Engine (SSME) is summarized. An emphasis was placed on near term technology through requirements to use existing SSME instrumentation and to demonstrate the HMS during SSME ground tests within five years. The HMS framework was developed through an analysis of SSME failure modes, fault detection algorithms, sensor technologies, and hardware architectures. A key feature of the HMS framework design is that a clear path from the ground test system to a flight HMS was maintained. Fault detection techniques based on time series, nonlinear regression, and clustering algorithms were developed and demonstrated on data from SSME ground test failures. The fault detection algorithms exhibited 100 percent detection of faults, had an extremely low false alarm rate, and were robust to sensor loss. These algorithms were incorporated into a hierarchical decision making strategy for overall assessment of SSME health. A preliminary design for a hardware architecture capable of supporting real time operation of the HMS functions was developed. Utilizing modular, commercial off-the-shelf components produced a reliable low cost design with the flexibility to incorporate advances in algorithm and sensor technology as they become available.

Hawman, Michael W.↗