Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid responsive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

VSC-HVDC Interties for Urban Power Grid Enhancement

Urban power grids are facing many operational and expansion challenges to meet further demand growth and increased reliability requirements. Advanced transmission technologies have been considered by the electric utilities to effectively increase the utilization of existing infrastructure and operational flexibility. The focus of this paper is on VSC-HVDC technologies for urban power grid enhancement and modernization. First, a potential technical scheme is proposed for converting an existing AC circuit to DC operation, which could boost the power transfer capability of the critical transmission corridor and increase network operational flexibility. Second, this paper proposes three operation modes for the VSC-HVDC interties in urban power grids corresponding to normal, emergency and island operating conditions, respectively. An integrated, adaptive emergency control strategy (AEC) is proposed that can enable adaptive power flow responses of the VSC-HVDC intertie under varying system operating conditions and critical contingencies. The flexibility and effectiveness of the proposed operational principles of urban VSC-HVDC intertie and the corresponding control strategies are verified in PSCAD/EMTDC using a realistic urban power grid in China.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Systemic Drivers of Electric-Grid-Caused Catastrophic Wildfires: Implications for Resilience in the United States

Wildfires are projected to increase in severity and frequency due to climate change, and the electric grid is both a cause of wildfires and is vulnerable to wildfires. Equipment from the electric grid accounts for 10% of fires burned in California and 3% of fires nationally. Recent catastrophic wildfires, such as the Lahaina Fire, Camp Fire, Marshall Fire, and Smokehouse Creek fires, were all started by electrical equipment and show how devastating these events can be because they threaten lives and structures. Vegetation structure, weather and winds, climate and vegetation response, land use, and human activities all impact the likelihood of severe wildfires. We explore the relationship between the built environment, electric grid infrastructure specifically, and its role in causing catastrophic wildfires to find lessons learned for increasing resilience. Electric grid utility companies currently employ multiple methods to mitigate fire, including (1) early detection, (2) grid hardening, (3) vegetation management, and (4) pre-emptive shutoffs. Utility companies need to consider the conditions for wildfire and the impact that each mitigation strategy has on drivers of wildfire behavior, as a single solution will not be adequate. Utility companies need to work with stakeholders to develop a holistic strategy to reduce ignition likelihood and spread likelihood to reduce catastrophic wildfires and improve resiliency.

Eagleston, Holly (ORCID:0000000178175116)↗

Decarbonization of the Electric Power Sector and Implications for Low-Cost Hydrogen Production from Water Electrolysis

Increasing development of wind and solar generation in the power sector can create economic opportunities for the deployment of water electrolyzers that produce hydrogen. Temporal variation in the marginal cost of energy in future decarbonized grids can make it favorable for electrolyzers to dispatchably ramp hydrogen production up and down in response to low- and high-cost times. Using this strategy, low-cost hydrogen production is enabled by electrolyzers that are low-capital cost and tolerant to frequent on/off cycling. Ramping down hydrogen production to a designated turndown ratio can avoid performance degradation caused by on/off cycling by not shutting the electrolyzer completely off. This comes with a slight cost penalty which can be minimized if the turndown ratio is low (i.e., the system ramps down hydrogen production to close to zero). These results suggest that electrolyzers integrated into future power systems are likely to benefit from the ability to ramp operation up and down quickly and operate in a standby mode. This analysis forms a basis for comparative tradeoffs between electrolyzer capital cost, operating strategy, and system durability and demonstrates the importance of considering all three factors in technoeconomic analysis.

capital cost↗

Detection of young (≤20 Myr) stellar populations in apparently quenched low-mass galaxies using red spectral line indices

ABSTRACT We report on the detection of a small contribution (around and below 1 per cent in mass) from young stellar components with ages ≤20 Myr in low-mass galaxies purposely selected from the MaNGA survey to be already-quenched systems. Among the sample of 28 galaxies, 8 of them show signatures of having suffered a very recent burst of star formation. The detection has been done through the analysis of line-strength indices in the red spectral range [5700,8800] Å. The increasing contribution of red supergiants to this red regime is responsible for a deviation of the index measurements with respect to their position within the model grids in the standard spectral range [3600,5700] Å. We demonstrate that a combination of red indices, as well as a qualitative assessment of the mean luminosity-weighted underlying stellar population, is required in order to distinguish between a true superyoung population and other possible causes of this deviation, such as abundance ratio variations. Our result implies that many presumably quenched low-mass galaxies actually contain gas that is triggering some level of star formation. They have, therefore, either accreted external gas, internally recycled enough gas from stellar evolution to trigger new star formation, or they kept a gas reservoir after the harassment or stripping process that quenched them in the first place. Internal processes are favoured since we find no particular trends between our non-quenched galaxies and their environment, although more work is needed to fully discard an external influence.

de Lorenzo-Cáceres, A.↗

Hierarchical Model-Free Transactive Control of Residential Building Loads: An Actual Deployment

The transformation of electricity systems into more sustainable configurations brought some new challenges. The uncertain, intermittent, and variable nature of renewable energy sources require a significant amount of load demand flexibility, in which grid-interactive buildings (GEBs) are important flexible assets for electricity systems. In this regard, many demand response (DR) tools have been developed to harness this demand flexibility. However, such tools are mostly simulation-based or deal with a single load, which may not be sufficient to demonstrate their effectiveness. Towards this end, this paper presents a real-world field implementation and testing of a hierarchical model-free transactive DR control approach on actual GEBs. The control implementation incorporates elements of virtual battery, game theory, and model-free control mechanisms. The proposed approach was tested using a total of five GEBs, each having three zones. The results show that the proposed approach can mostly achieve all intended objectives, including flexibility estimation, peak load reduction, power tracking, and controlling GEBs while maintaining occupants’ comfort.

Amasyali, Kadir↗

Robust Stabilization of Inverter-Based Resources Using Virtual Resistance-Based Control

This letter proposes a virtual resistance-based nonlinear control to stabilize and robustify the current layer of inverter-based resources, subject to the grid voltage disturbances, and the grid parameter uncertainties. A class of virtual resistances is proposed and analyzed using concepts from dissipative systems theory. Moreover, specific nonlinear virtual resistance-based controllers are derived, with their corresponding performance analytically bounded. Here, the theoretical and simulation results show that the proposed nonlinear virtual resistance-based controllers significantly reduce the L 2 gain of the closed-loop error system to grid voltage variation and parametric uncertainties. Significant improvements of the transient and steady-state current responses are also demonstrated over linear virtual resistance counterparts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resident Tolerance to Transitional Temperature Deviation in Smart Communities

Choosing the right HVAC system or the right algorithm of implementing demand response may create significant energy and environmental gains while maintaining resident comfort. But these questions are closely related to the concept of user comfort, which in turn requires a reasonable fit between user preferences and temperature setpoints. While setting the temperature right is a well-researched question, systems in transition from one setpoint to another are currently not thoroughly addressed in research. But how tolerant the residents really are if a system spends a large share of time outside of the comfort setpoint. This study gives some early insights on how the deviation of temperature from the setpoint affect perceived resident comfort. We use two weeks of data for a smart neighborhood located in Atlanta, GA. We find that the system spends 20% - 50% of time deviating from the setpoint by more than 1℉. However, we do not find that increasing deviations cause resident complaints or increasing overrides.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Market-Based Coordination of Thermostatically Controlled Loads—Part II: Unknown Parameters and Case Studies

This two-part paper considers the coordination of a population of Thermostatically Controlled Loads (TCLs) with unknown parameters to achieve group objectives. The problem involves designing the bidding and market clearing strategy to motivate self-interested users to realize efficient energy allocation subject to a peak power constraint. The companion paper (Part I) formulates the problem and proposes a load coordination framework using the mechanism design approach. To address the unknown parameters, Part II of this paper presents a joint state and parameter estimation framework based on the expectation maximization algorithm. The overall framework is then validated using real-world weather data and price data, and is compared with other approaches in terms of aggregated power response. Simulation results indicate that our coordination framework can effectively improve the efficiency of the power grid operations and reduce power congestion at key times.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Improving Primary Frequency Response to Support Networked Microgrid Operations

Individual microgrids have proven their ability to provide uninterrupted power to critical end-use load during severe events. Building on the performance of individual microgrids during extreme events, there has been an increasing interest in the operations of network microgrids. By networking microgrids during extreme events, it is possible to share resources, increase the duration for which they can operate islanded, and increase the resiliency of critical end-use loads. While there are benefits to networking the operations of resiliency-based microgrids, the switching operations that they require introduce transients which can result in a loss of dynamic stability. The issue of dynamic stability is especially acute in microgrids with high penetrations of inverter-connected generation, and a correspondingly low system inertia. While the low-inertia of these microgrids can be increased by over-sizing the rotating generators, the increased capital and operating costs can become a barrier to deployment. This work will present a method of augmenting primary frequency controls to support the switching transients necessary for the operation of networked microgrids, without the need to over-size rotating machines.

24 POWER TRANSMISSION AND DISTRIBUTION↗

EMOS (Energy Management Optimization System) [SWR-21-46]

EMOS software performs a real-time hierarchal optimal control for energy systems like multi-port electric vehicles charging site with distributed energy resources (DERs) and energy storage systems (ESSs). It gathers information in real-time from electric vehicles, power grid, and DERs, solves a multi-objective energy management optimization problem, and output setpoint for chargers, ESS converters, DERs converters, and grid converters. The software incorporates a novel integration of two control tasks: a) An Energy Management Optimization (EMO), which is the brain of EMOS controller that gathers information in real-time from EVs [e.g., battery size, state-of-charge (SOC), desired SOC, and charge acceptance curve], grid (e.g., electricity price, allowed feeder capacity, ramp rate limit, and reactive power), and DERs (e.g., prediction for solar generation for PV systems). It solves a control optimization problem in real-time to find optimal setpoint for ESSs power dispatch, EVs charging rate, and grid inverters. The objectives are to (1) minimize the charging cost considering grid energy, demand charges, and battery energy, (2) minimize charging time to meet fast charging criterion, (3) keep high energy level on ESSs at the end of an operating period, while satisfying constraints related to grid, EVs, and power converters. b) Real-Time Energy Management System (RT-EMS) is a rule-based algorithm that has faster response than EMO. It receives optimal setpoint from EMO and actual measurements from the system and modify the setpoint to compensate for any fast disturbance in the system, until a new optimum solution is received. Fast disturbances may include vehicle connect/disconnect, unpredicted variation in DERs profiles, variation in grid voltage, errors in PV generation prediction, and others. In addition, RT-EMS regulates voltage at point of common coupling (PCC) by managing reactive power of grid converters.

Mohamed, Ahmed↗

VOLTTRON 2016

VOLTTRON is a flexible, reliable, and scalable platform for distributed control and sensing. VOLTTRON serves in four primary roles: •A reference platform for researchers to quickly develop control applications for transactive energy. •A reference platform with flexible data store support for energy analytics applications either in academia or in commercial enterprise. •A platform from which commercial enterprise can develop products without license issues and easily integrate into their product line. •An accelerator to drive industry adoption of transactive energy and advanced building energy analytics. Pacific Northwest National Laboratory, with funding from the U.S. Department of Energy’s Building Technologies Office, developed and maintains VOLTTRON as an open-source community project. VOLTTRON source code includes agent execution software; agents that perform critical services that enable and enhance VOLTTRON functionality; and numerous agents that utilize the platform to perform a specific function (fault detection, demand response, etc.). The platform supports energy, operational, and financial transactions between networked entities (equipment, organizations, buildings, grid, etc.) and enhance the control infrastructure of existing buildings through the use of open-source device communication, control protocols, and integrated analytics.

97 MATHEMATICS AND COMPUTING↗

Atmospheric System Research Treatment of Convection in Next-Generation Climate Models: Challenges and Opportunities Workshop Report

A workshop sponsored by the U.S. Department of Energy (DOE) Atmospheric System Research (ASR) Program was held at the Pacific Northwest National Laboratory (PNNL) on 3-5 February 2016. This workshop was a response to the rapid approach of climate models with cloud-permitting (1- to 10-km grid spacing) resolutions. The expansion of computational resources and advances in numerical methods are making such models a reality. The workshop participants considered specifically the new set of challenges for representing convective cloud processes in this generation of models. The challenges arise from the fact that some aspects of convection are partly resolved. Short- and long-term strategies that would lead to accurately representing convection in these models were discussed, and opportunities for the ASR program to effectively leverage DOE’s unique capabilities, high-performance computing resources, and Atmospheric Radiation Measurement (ARM) Climate Research Facility observational facilities to this end were identified. The workshop was organized around the premise that a strategy to accurately treat convection in the next generation of climate models comprises addressing challenges on three core themes and their integration.

54 ENVIRONMENTAL SCIENCES↗

NASTRAN maintenance and enhancement experiences

The current capability is described which includes isoparametric elements, optimization of grid point sequencing, and eigenvalue routine. Overlay and coding errors were corrected for cyclic symmetry, transient response, and differential stiffness rigid formats. Error corrections and program enhancements are discussed along with developments scheduled for the current year and a brief description of analyses being performed using the program.

Schmitz, R. P.↗

Design efficiency evaluation for transonic airfoil optimization - A case for Navier-Stokes design

A constrained-optimization design method which improves the aerodynamic performance of transonic airfoils is evaluated from a design-quality and design-efficiency viewpoint. Design efficiency is a measure of the performance improvement and the design time (CPU time). Total-airfoil design and upper-surface design are performed using the Euler and Navier-Stokes equations with several grids, and are evaluated using the Navier-Stokes equations to determine the anticipated physical design response. Even though the cost of the Euler design is lower than Navier-Stokes design, the Navier-Stokes evaluation indicates that the Euler design does not necessarily improve the aerodynamic performance. Therefore, the design optimization should be based on an accurate flow simulation to achieve an actual performance improvement, and the design time is a secondary concern.

Hager, J. O.↗

NASA Tech Briefs, October 2005

Topics covered include: Insect-Inspired Optical-Flow Navigation Sensors; Chemical Sensors Based on Optical Ring Resonators; A Broad-Band Phase-Contrast Wave-Front Sensor; Progress in Insect-Inspired Optical Navigation Sensors; Portable Airborne Laser System Measures Forest-Canopy Height; Deployable Wide-Aperture Array Antennas; Faster Evolution of More Multifunctional Logic Circuits; Video-Camera-Based Position-Measuring System; N-Type delta Doping of High-Purity Silicon Imaging Arrays; Avionics System Architecture Tool; Updated Chemical Kinetics and Sensitivity Analysis Code; Predicting Flutter and Forced Response in Turbomachinery; Upgrades of Two Computer Codes for Analysis of Turbomachinery; Program Facilitates CMMI Appraisals; Grid Visualization Tool; Program Computes Sound Pressures at Rocket Launches; Solar-System Ephemeris Toolbox; Data-Acquisition Software for PSP/TSP Wind-Tunnel Cameras; Corrosion-Prevention Capabilities of a Water-Borne, Silicone-Based, Primerless Coating; Sol-Gel Process for Making Pt-Ru Fuel-Cell Catalysts; Making Activated Carbon for Storing Gas; System Regulates the Water Contents of Fuel-Cell Streams; Five-Axis, Three-Magnetic-Bearing Dynamic Spin Rig; Modifications of Fabrication of Vibratory Microgyroscopes; Chamber for Growing and Observing Fungi; Electroporation System for Sterilizing Water; Thermoelectric Air/Soil Energy-Harvesting Device; Flexible Metal-Fabric Radiators; Actuated Hybrid Mirror Telescope; Optical Design of an Optical Communications Terminal; Algorithm for Identifying Erroneous Rain-Gauge Readings; Condition Assessment and End-of-Life Prediction System for Electric Machines and Their Loads; Lightweight Thermal Insulation for a Liquid-Oxygen Tank; Stellar Gyroscope for Determining Attitude of a Spacecraft; and Lifting Mechanism for the Mars Explorer Rover.

Source record↗

Grid Sensitivity Study for Slat Noise Simulations

The slat noise from the 30P/30N high-lift system is being investigated through computational fluid dynamics simulations in conjunction with a Ffowcs Williams-Hawkings acoustics solver. Many previous simulations have been performed for the configuration, and the case was introduced as a new category for the Second AIAA workshop on Benchmark problems for Airframe Noise Configurations (BANC-II). However, the cost of the simulations has restricted the study of grid resolution effects to a baseline grid and coarser meshes. In the present study, two different approaches are being used to investigate the effect of finer resolution of near-field unsteady structures. First, a standard grid refinement by a factor of two is used, and the calculations are performed by using the same CFL3D solver employed in the majority of the previous simulations. Second, the OVERFLOW code is applied to the baseline grid, but with a 5th-order upwind spatial discretization as compared with the second-order discretization used in the CFL3D simulations. In general, the fine grid CFL3D simulation and OVERFLOW calculation are in very good agreement and exhibit the lowest levels of both surface pressure fluctuations and radiated noise. Although the smaller scales resolved by these simulations increase the velocity fluctuation levels, they appear to mitigate the influence of the larger scales on the surface pressure. These new simulations are used to investigate the influence of the grid on unsteady high-lift simulations and to gain a better understanding of the physics responsible for the noise generation and radiation.

Lockard, David P.↗