Search NASA⌕ Search

SEARCH · Search NASA

Results for “high-temperature testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Magnet Architectures and Active Radiation Shielding Study (MAARSS)

This report describes the analysis of several magnetic radiation shield architectures and the spacecraft systems associated with them, such as quench detection, thermal management, and compensation coils. This work was performed as part of the NASA Institute of Advanced Concepts (NIAC) Grant Phase II effort. Because radiation exposure during long duration space missions poses a significant risk for crewed space-flight, Advanced Magnetic Lab, Inc. (AML) and NASA are studying magnetic radiation shielding, which may generate low-mass protection. Recent technological developments in high-temperature superconducting technology suggest the possibility of such shielding. This report analyzes some of the technical difficulties involved in such a system and identifies technology areas where further investment would be warranted. Most analysis was performed on a baseline configuration (8-meter diameter coils, with 1 tesla field). However, a baseline design with an expandable coil configuration (16 meter diameter coils, 1.5 tesla field) has a significant potential to increase shielding efficiency. The magnetic forces on the magnetic shield's components are large enough to require detailed structural design. Analysis of the thermal structural response of a yttrium-barium-copper-oxide (YBCO) high-temperature, superconducting (HTS) tape in a large-scale solenoid magnet showed that structural and thermal performance improved by replacing Hastelloy® with graphene in the tape. Integrating graphene into the high-strength fiber (HSF) support structure brings even greater benefits. The energy stored in a shield system's magnetic field must be safely dissipated if a quench-type failure occurs. Analysis of quench detection by fiber-optic thermal sensing and improvement of quench characteristics using graphene showed quench is manageable. Low-temperature superconductors can quench when subjected to movement, but lab tests of coil expansion testing showed that HTS materials do not quench when subject to the movement associated with coil expansion. Compensation coils are necessary to reduce the magnetic field in the crew habitat. Analysis showed that subdividing the compensation coil into individually controlled sections allows for a robust, adjustable system. AML analyzed the forces on an approaching capsule that were a result of eddy currents in its structure induced by its motion through the magnetic field from the coils. AML also analyzed coil-to-coil forces. Thermal control to maintain the HTS material at a suitable temperature is challenging. The sunshield technology review revealed a greater possibility of thermal insulation of the coils and use of passive cooling. The availability of suitable cryocoolers was also reviewed. A parametric graph estimating mass and shielding effectiveness for strength and thickness was developed, and allows spacecraft designers to assess the tradeoffs of using a magnetic radiation shield.

Spacecraft↗

Internal Electrostatic Discharge Testing of Inert Solid Rocket Motor Materials

Jupiter’s moon Europa is believed to have a global liquid-water ocean beneath its icy surface. As such, it is a highly interesting destination for explorers seeking signs of life outside of Earth. This interest has given rise to the Europa Lander Mission [Hand, et al., 2017]. The central goal of the Europa Lander Mission is to place a stationary lander on Europa and make surface and sub-surface measurements, dramatically improving understanding of this Jovian moon, and potentially detecting signs of life.Placing a lander on Europa will require multiple spacecraft elements deployed across a multi-year mission timeline. Some of the key elements include: a large payload capacity rocket, such as the Space Launch System (SLS), capable of providing direct Jupiter orbit insertion; a solar-powered carrier; a de-orbit system; a sky crane landing system; and, of course, the surface lander. A noteworthy fact is that the current design requires a large solid rocket motor to provide the necessary braking thrust for the de-orbit stage. While solid rocket motors have been used extensively by NASA during launch, in-space use has been limited. In addition to the normal challenges associated with a long-distance planetary mission, the Europa Lander Mission must also contend with the high-radiation environment associated with the Jovian system. The size of Jupiter, combined with its magnetic field strength, and rotation speed, result in a harsh radiation environment composed of high energy charged particles (ions and electrons) as well as high-temperature plasmas [de Soria-Santacruz Pich, 2016]. Due to this high-radiation environment, each component of the Europa Lander spacecraft must be evaluated to determine its radiation dose tolerance and its likelihood for experiencing electrostatic charging (and discharging). In general, metal components in a Jovian environment do not pose a concern for radiation degradation; in fact, metal structures and closeouts can act as radiation shielding for the more sensitive components. Charging of a metal component is only an issue if the component is not properly grounded to the spacecraft chassis. However, electrically insulating materials, such as polymers, are subject to radiation degradation as well as surface and internal charging, and therefore require extra scrutiny. The focus of this paper will be on the insulating materials that are commonly used inside solid rocket motors. The special application of a solid rocket motor used in space after a relatively long duration flight, combined with the high energy electron environment in the Jovian system, raises concerns about the possibility of significant charging and discharging leading to reduced performance.

Schneider, Todd A.↗

Progress in Additively Manufactured Copper-Alloy GRCop-84, GRCop-42, and Bimetallic Combustion Chambers for Liquid Rocket Engines

Additive Manufacturing (AM) has significantly evolved over the last decade for use in the aerospace industry, particularly for liquid rocket engines. AM offers a considerable departure from traditional manufacturing to rapidly fabricate components with complex internal features. High performance liquid rocket engine combustion chambers that operate in a high heat flux environment are fabricated using a copper-alloy liner with a series of integral coolant channels. Copper-alloys provide the necessary conductivity and material strength for adequate design margins offering high performance without the need for film coolant. Copper-alloys present unique challenges to properly melt the powder in laser-based AM processes due to their high reflectivity and conductivity. Starting in 2014, NASA’s Marshall Space Flight Center (MSFC) and Glenn Research Center (GRC) have developed a process for AM of GRCop (Copper- Chrome-Niobium) alloys using Selective Laser Melting (SLM). GRCop, originally developed at GRC, is a high conductivity, high-strength, dispersion strengthened copper-alloy for use in high-temperature, high heat flux applications. NASA has completed significant material characterization and testing, along with hot-fire testing, to demonstrate that GRCop-42 and GRCop-84 alloys are suitable for use in combustion chambers. Additional development and testing has been completed on AM bimetallic chambers using GRCop-84 liners and superalloy jackets, fabricated using two Directed Energy Deposition (DED) processes: Electron Beam Freeform Fabrication (EBF³) and Blown Powder DED. NASA completed hot-fire testing on various AM chambers using GRCop-84, GRCop-42, and bimetallic chambers in Liquid Oxygen (LOX)/Hydrogen, LOX/Methane, and LOX/Kerosene propellants.

Gradl, Paul R.↗

TPSAS-NF1676L-24485-DND

Hybrid composite laminates that contain alternating layers of titanium alloys and carbon fabric reinforced polyimide matrix composites (PMC) are excellent candidates for light-weight, high-temperature structural materials for high-speed aerospace vehicles. The delamination resistance of the hybrid titanium-PMC interface is of crucial consideration for structural integrity during service. Here, we report the first investigations on the use of laser ablation in combination with sol-gel treatment technique on Ti/NiTi foil surfaces in co-cured hybrid polyimide matrix composite laminates. Mode-I and mode-II fracture toughness of the hybrid Ti/NiTi-PMC interface as a function of temperature were determined via experimental testing and finite element analysis.

John Connell↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods.This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel. An ultrasonic scanner was enclosed in a nitrogen-cooled insulating box that prevented thermal damage from the industrial oven to the temperature-sensitive electronics. Inspection of the composite part was performed through the bottom of the enclosure, which served as the tool plate for the part. In this study, a porosity gradient was introduced through a misfit of the part and caul plate. Using the data obtained from B-scans and amplitude C-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

In-process, Defect Detection, Cure Monitoring, Por↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) Solar Sounding Rocket Campaign – Calibration and Performance

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket experiment that is designed to observe, for the first time, soft X-ray spectra of high-temperature, low-emission plasma of coronal structures spatially resolved along a narrow slit.MaGIXS observation involves a set of high temperature spectral lines in soft X-rays from 0.5 - 2.0 keV from an active region core,which will extend the DEM coverage from 3MK to 10MK constraining the slope of the DEM fall-off. The novel instrument designincludes a Wolter-I type telescope and a 3-optic grazing-incidence spectrometer. The spectrometer consists of a finite conjugatemirror pair and a blazed planar, varied line spaced grating, which disperses the rays on to a CCD and provides a high spatial andspectral resolution. Component level instrument testing, integration of the instrument and end-to-end X-ray calibration are carriedout using the X-ray and Cryogenic Facility (XRCF) at NASA Marshall Space Flight Center. MaGIXS is scheduled for launch in2021. We will present the results of X-ray calibration tests for MaGIXS and discuss the expected inflight performance throughdifferent solar observation scenarios.

P. S. Athiray↗

Analysis of PICA-NuSil at the Hypersonic Materials Environmental Test System (HyMETS)

Phenolic Impregnated Carbon Ablator (PICA) gained heritage during the stardust mission and is the baseline material for missions to Mars. The phenolic phase of PICA is friable, and therefore the surface is treated with a siloxane resin (NuSil) to mitigate the shedding of particulate matter. Historically, material response models have not accounted for the presence of this coating. Therefore, a test campaign was executed at the Hypersonic Materials Environmental Test System (HyMETS) to investigate the performance of NuSil under multiple heating rates and gas composition. Sphere-cone models were instrumented with thermocouples to measure the in-depth temperature response, and surface temperatures were monitored with a pyrometer. Furthermore, emission spectrometers were used to collect spectra from species emitting at the surface of the test article and the post-shock stagnation region. Post-test analysis suggests that the coating decomposes according to multiple stages. Inspection of silicon emission data reveals a rapid rise and decline in intensity within the first couple of seconds of testing, which is attributed to pyrolysis of NuSil. Pyrolysis is followed by a stagnation in silicon emission and surface temperature which are attributed to the formation of a thin layer of oxidation-resistant silicon oxycarbide. Moreover, the presence of the silicon oxycarbide layer significantly reduces the in-depth thermal response when compared to the baseline material. Eventually, the silicon oxycarbide layer decomposes via high-temperature reactions, which expose the underlying char layer to a highly reactive flow.

PICA-NuSil↗

Material Properties and Modeling of Room Temperature Vulcanizing Silicone

Room Temperature Vulcanizing silicone (RTV) is a high-temperature adhesive that has successfully been used as a gap-filler between Thermal Protection System (TPS) tiles for heatshields on numerous missions. It is also used to bond instrumentation plugs such as temperature and pressure sensors into the heatshields. While RTV has been traditionally assumed to be a non-porous and non-ablating material, numerous experiments have shown that RTV pyrolyzes and becomes highly porous as it is heated. Heating RTV has also shown swelling, or intumescence, which can pose unique problems that lead to roughness induced boundary-layer transition, surface oxide formation and contamination of heat shield sensors. Therefore, it is crucial to understand and model the intumescence phenomenon of RTV. As data for RTV material properties is limited, the first step in modeling RTV is to collect material properties such as pyrolysis mass-loss, microstructure change, virgin and char porosity, etc. which was performed in our initial study. Additionally, thermomechanical properties such as Young’s modulus and Poisson ratio are required for modeling the intumescence of RTV, which were taken from literature and the coefficient of thermal expansion was collected using in-situ heating and Micro Computed Tomography (µ-CT) in previous studies. Finally, numerous other properties such as pyrolysis gas properties, virgin and char thermal conductivity and specific heat were compiled from previous experiments and literature into a material database that can be used for simulations. In Porous Material Analysis Toolbox based on OpenFOAM (PATO) [4], structural mechanics coupled with material response was used for simulating the intumescence of RTV as it is heated. However, since the permeability of the material is very low, the pyrolysis gas creates an internal pressure build-up as the material is being heated, significantly contributing to the deformation of the material. To correctly characterize this phenomenon, additional physics models were implemented into PATO's stress analysis solver, and results were compared with RTV dilatometry test data as a preliminary verification case. Future work will include experiments of RTV at the Plasmatron X facility and the in-situ heating cell with µ-CT, and improvement of simulation tools to more accurately model RTV intumescence.

PATO↗

Improving Adhesive Bondline Time of Flight Predictions During Autoclave Cure Utilizing Machine Learning

Composite materials are increasingly being used in aerospace applications due to their superior strength-to-weight ratio compared to commonly used metals. A current limitation to widespread adoption is the certification of adhesively bonded joints. One approach to improving adhesive bonding in composites is accurately measuring the thickness of adhesive bondlines in composite laminates. Precise bondline thickness control is essential for aerospace applications where adhesive layer thickness directly affects joint fracture properties and structural performance. This study focused on implementing machine learning techniques to determine the ultrasonic time of flight (directly correlated to thickness) in adhesive bondlines throughout autoclave cure cycles. A high-temperature (use up to 180°C) ultrasonic scanning system was deployed in an autoclave to provide time of flight data through composite panels. Three experiments were conducted on the curing of 305 mm × 305 mm unidirectional composite panels. In the first experiment, a piecewise function was fit for the temperature correction factor to account for changing autoclave temperatures. Due to deficiencies in the first calibration experiment, a second experiment was run, and the results were used to train a machine learning model. The revised experiment, in combination with the machine learning model, significantly increased the accuracy of the bondline time of flight predictions (~14% error reduced to <1%). Data was processed using the Regression Learner Application in MATLAB®, with a Support Vector Machine selected for the model. The result was a machine learning algorithm capable of reliably quantifying ultrasonic time of flight through adhesive bondlines. The third experiment provided independent test data for the machine learning model, demonstrating that the model produces accurate predictions from data beyond its training set.

Machine Learning↗

Advanced Materials for the Lunar Surface: Multiscale Computational Design of Refractory Alloys and Carbides

Emerging operational environments, such as the lunar surface, present novel challenges for NASA and drive the need for advanced materials in applications like fission surface power systems. To address these demands, computational materials science is rapidly evolving to augment or replace costly and hazardous empirical testing. Although materials selection at NASA remains predominantly experimentally driven, advanced simulation methodologies are being steadily integrated into the engineering lifecycle. This work details the application of multiscale simulation techniques—including first-principles calculations, CALPHAD, dislocation dynamics, and molecular dynamics—at NASA's Ames Research Center to evaluate advanced materials for extreme environments. First, we present contributions to the Space Nuclear Propulsion Project. Be-cause propellant channel coatings in nuclear thermal rockets must withstand high-pressure, high-temperature hydro-gen, optimizing these materials is critical. First-principles calculations were employed to establish a rigorous quantitative and qualitative understanding of the behavior of the refractory carbides ZrC, NbC, and their mixtures in high-enthalpy hydrogen environments. This necessitated the generation of high-fidelity thermodynamic models for both stoichiometric and carbon-depleted carbides, both with and without the presence of hydrogen. Furthermore, we highlight efforts under the Refractory Alloy Additive Manufacturing Build Optimization (RAAMBO) project, where existing and novel alloy compositions were assessed for additive manufacturing printability and subsequent performance in applications such as heat pipes and rocket nozzle extensions. This was accomplished through a comprehensive multiscale simulation framework that bridged the gap from the nanometer to the millimeter scale. Across both initiatives, rigorous validation against empirical data was prioritized. By systematically employing a verified and validated computational frame-work, we demonstrate how simulation effectively supports multidisciplinary engineering efforts, builds project-wide confidence, and drives critical materials development.

computational materials↗

Multi-physics Modeling of Radiative Heat Transfer and Fluid Flow for the Reactor Cavity Cooling System

High-temperature gas-cooled reactors (HTGRs) are notable for their high thermal efficiency and potential for combined heat and power applications. These reactors are particularly appealing due to their advanced passive safety features. HTGRs utilize passive safety systems that function without requiring active components like pumps or compressors during emergencies. These reactor designs depend on a Reactor Cavity Cooling System (RCCS) to manage decay heat removal from the reactor pressure vessel (RPV) during accident conditions. The RCCS consists of vertical rectangular channels known as "risers" or riser ducts positioned around the RPV. These risers receive heat from the RPV through both convective and radiative heat transfer mechanisms. Understanding the interplay of multiple physical phenomena, such as fluid dynamics, heat transfer, and neutron interactions, is essential for the effective design and operation of nuclear reactors, particularly for systems like the RCCS. Multi-physics simulations provide a comprehensive approach to studying these interactions, offering detailed insights and enhancing accuracy. They are especially important in RCCS designs, where the interaction between radiative and convective heat transfer can significantly impact system performance. By leveraging multi-physics simulations, complex reactor behaviors can be modeled without compromising the fidelity of the underlying physical processes. This work aims to establish a robust methodology for coupling multiple physical processes in an air-cooled RCCS. By focusing on validating this multi-physics approach, the study involves designing test cases that simulate various conditions to verify the numerical models employed. The outcomes of this research will provide critical insights for accurately modeling and optimizing complex nuclear systems like the RCCS.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computational Fluid Dynamics Simulations of Glass Vitrification Refractory Coupon Tests

The Waste Treatment and Immobilization Plant (WTP) at the Hanford site is nearing the start of the Direct-Feed Low-Activity Waste (DFLAW) operations. DFLAW is destined to convert a pretreated low activity waste portion of the 56 million gallons of tank waste into a stable solid glass. In the subsequent decade completion of the high-level waste (HLW) facility is anticipated. Sustained operational missions of both LAW and HLW melter facilities are expected over multiple decades. In high-temperature glass melters, the refractory lining corrodes over time, which could potentially be an issue for longer term operations, this refractory corrosion is higher at the level of the glass-air interface due to surface tension driven flow. The glass viscosity, melt pool temperature, and glass chemical composition can impact the rate at which the refractory corrodes. This rate is important to quantify for the various waste glasses to be produced at the WTP since the integrity of the refractory should not be a limiting factor affecting the lifetime of the melter. To this end, a series of glasses representative of the first batches of waste glass produced by the WTP will be melted in small-scale crucibles with Monofrax® K-3 coupons inserted. The corrosion of the K-3 will be measured in the melt and at the meltline (or neckline). A model for the corrosion rate will be constructed and implemented into a previously developed framework for a computational fluid dynamics (CFD) model of the full-scale WTP. To assist with experimental design and validate the implementation of the model in the full-scale melter, CFD simulations of the small-scale crucible tests were performed. The bubbling that occurs in the small-scale crucible is initially validated here with a model that uses silicone oil at room temperature. The viscosity of the oil ranges from 1 to 100 Pa•s, which corresponds to operating glass pool temperatures near 1150 °C down to idling temperatures near 950 °C. The simulation results show good agreement with the bubble sizes that form during experiments. CFD modeling of the crucible setup was used to determine bubbling characteristics to match the range of near-wall velocities expected in the full-scale WTP. This study presents the initial CFD modeling results, corrosion testing plan, and some preliminary corrosion samples with an outline for the next steps for the development of the corrosion model.

Abboud, Alexander W. [Idaho National Lab]↗

Report on the Assessment of Ion Irradiations on High Entropy Alloys

Idaho National Laboratory (INL) initiated a joint international effort with the Czech Republic to explore the feasibility of manufacturing High Entropy Alloys for high-temperature nuclear applications using Additive Manufacturing. This effort was funded at INL by the United States Department of Energy’s Office of Nuclear Energy under the Advanced Reactor Technologies and Advanced Materials and Manufacturing Technologies (AMMT) Program. The High Entropy Alloys were specifically designed for the corrosive and irradiation environments as experienced in gas fast reactors, molten salt reactors, and fusion power. These alloys were manufactured by multiple processes to determine the impact of manufacturing processes on the performance of the alloys in corrosive and irradiation environments. Preliminary results show that MoNbTiV and MoNbTi alloys exhibit no degradation after multiple corrosion tests. These MoNbTiV and MoNbTi alloys were also evaluated after irradiation experiments were conducted at the Michigan Ion Beam Laboratory at the University of Michigan, which is the focus of this milestone report. For these irradiation experiments, the MoNbTiV and MoNbTi alloys manufactured by arc melting and Electric Field Assisted Sintering (EFAS) were tested at 500 C at a dose of 30 dpa to evaluate the microstructural stability and decomposition.

36 - MATERIALS SCIENCE↗

MARVEL Reactor Fuel Performance Report

The Microreactor Applications Research Validation and EvaLuation (MARVEL) project is producing a high temperature liquid metal-cooled nuclear test bed at Idaho National Laboratory (INL) to ultimately improve the integration of microreactors to end-user applications. This ambitious effort seeks to design, authorize, construct, test, and operate the reactor within five years. In order to construct and operate the MARVEL reactor in a timely manner, the system will utilize materials and component designs which have already been used, qualified, or licensed from previous reactors. The MARVEL reactor will be located at the INL Transient Reactor Test (TREAT) facility in the north high-bay equipment pit and will use the existing 304 stainless steel-clad U-ZrH1.6 pin-type fuel system developed by General Atomics and purchased from TRIGA International. This fuel has been previously qualified under the United States Department of Energy’s (US DOE) Reduced Enrichment for Research and Test Reactors (RERTR) Program. Even though the regulator of the MARVEL reactor is the US DOE, the standards and overall approach recommended by the Nuclear Regulatory Commission is well-defined and utilized here. Following NUREG-1537 regulatory guidance, this report documents the authorization case for the MARVEL fuel system’s application to MARVEL and establishes stable and predictable fuel performance during the most thermophysically unfavorable conditions achievable in the MARVEL reactor. To that end, this report provides a comprehensive survey of the known thermophysical properties, performance, and quantitative relationships associated with the MARVEL reactor fuel element and uses this information to determine its mechanical integrity and risk of reaching unacceptable conditions during the most extreme accident scenarios predicted for the reactor using the most conservative assumptions available. The information contained herein is compiled from a combination of historical reports and peer reviewed scientific publication manuscripts. Known mechanisms under which the fuel is susceptible to failure are highlighted and compared to conditions that could exist in the MARVEL reactor during an unanticipated transient or accident scenario. The two scenarios considered for analysis in this report are (1) an unprotected loss of flow accident and (2) a hypothetical unprotected loss of coolant accident during the loss of flow accident. Preliminary 2D steady-state analyses herein indicate that both fuel-cladding chemical interactions and fuel-cladding mechanical interactions are negligible throughout the fuel’s operational cycle under both normal and high temperature accident scenario conditions. Although higher fidelity 3D time-dependent modeling and simulations are planned, the following may be concluded presently. The MARVEL fuel element maintains its geometric stability and structural integrity during the most extreme accident scenarios predicted for the MARVEL reactor. The hoop stress during the unprotected loss of flow accident reaches about -1.27 MPa; this negative stress indicates that it is compressive rather than tensile. The compressive stress is a result of the NaK pressure on the outside of the fuel element, caused by the restricted thermal expansion of the NaK coolant, exceeding the internal pressures generated inside of the fuel element. The hoop stress generated in the cladding during the unprotected loss of coolant accident reaches a maximum of about approximately 10 MPa, which is nearly an order of magnitude less than the predicted yield strength of the cladding under high-temperature accident scenario conditions. Calculations were compared with results from high performance computational simulations using BISON and are in very close agreement. A conservative MARVEL fuel meat peak temperature limit of 900 °C is recommended presently, which is about 180 °C higher than the peak fuel temperature predicted to occur during the most extreme accident. Based on the known properties and behavior of the MARVEL fuel element, the fuel successfully meets its design and safety requirements under normal and most extreme accident conditions with a large safety margin.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Status Report on the Development of Cladding Inner-wall and Outer-wall Coatings

Advanced cladding is critical for nuclear reactors with enhanced performance in radiation tolerance, neutron transparency and reactor safety. Using advanced cladding will ensure the adequate thermal conductivity and mechanical stability of the cladding base material, corrosion resistance and high-temperature coolant compatibility of the cladding surface, and chemical stability in the cladding inner wall against fuel cladding chemical interaction (FCCI). An innovative cladding with a three-layer structure (i.e., a modified outer surface, a robust clad base material, and a modified inner wall) promises to meet all these requirements. In this status report, the initial efforts on the development of cladding inner-wall and outer-wall coatings are summarized. The activities covered in this report are (1) High-resolution TEM studies of TiN/HT-9 interface atomic structure and chemistry after ion irradiation, (2) High-resolution TEM studies of TiN/14YWT ODS interface atomic structure after thermal cycling, (3) Inner-wall TiN coating for an experimental 14YWT ODS cladding, and (4) Corrosion test of TiN coated Ziracloy-4 bar samples.

36 - MATERIALS SCIENCE↗

Evaporator Temperature Transient Testing of a High-Performance Sodium Filled Heat Pipe

Heat pipes are two-phase heat transfer devices that enable passive removal of heat from the reactor core to the power conversion system in heat pipe-cooled microreactor designs. Experimental investigations of heat pipe transients are needed for technology demonstration, verification and validation of numerical codes, and the establishment of regulatory requirements. The Single Primary Heat Extraction and Removal Emulator (SPHERE) facility at Idaho National Laboratory (INL) serves as a platform for evaluating the dynamic response of high-temperature heat pipes under a variety of operating conditions. The present work details the experimental investigation of a high-performance, defined as over 2 kW sodium heat pipe subjected to rapid input power fluctuations induced by sudden changes in the evaporator temperature setpoint. In addition, the heat pipe was subjected to an asymmetrical heat load where a subset of heaters operated at 30% and 70% below their nominal power. These experimental conditions were chosen to simulate thermal and operational stresses expected to be encountered in microreactors to provide data on heat pipe behavior during such important transient events. Key data and performance metrics, including time series of temperatures and strains, axial temperature profiles, thermal response times, and heat transfer capabilities, the thermal output over thermal input, were reported and discussed. The results highlight the resilience of heat pipes, revealing their potential to maintain thermal stability and efficiency under varying power loads. Lastly, the paper concludes with a discussion on the significance of the results and their implications for future research.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Laser-Induced Breakdown Spectroscopy (LIBS) Sensing for Environmental and Subsurface Monitoring

Groundwater monitoring is essential to timely and accurately reflect the current situations and the trends of water quality. However, the long-term stability and survival of any potential in-situ monitoring method is threatened by the harsh conditions and the groundwater monitoring in downhole environments poses numerous challenges to the sensor community. Laser induced breakdown spectroscopy (LIBS) has been demonstrated as a promising technology for chemical monitoring in high-temperature high-pressure (HTHP) environments and hard to reach places. The technique demonstrates several advantages, such as rapid, real-time, in-situ, and simultaneous detection of multiple elements with simple or no sample preparation. This chapter includes a brief review of the field-portable LIBS systems, and development of a compact, robust, and simple LIBS instrument for downhole HTHP water quality monitoring. The fieldable prototype sensor is tested in an onsite monitoring well where trace elements’ concentrations are tracked over an extended period. The testing has verified that the fiber coupled design performs as desired. The system shows good calibration linearity for tested elements and collection times, and Limits of Detection (LODs) that are comparable to those of tabletop LIBS instruments. In addition to groundwater quality monitoring, the fabricated LIBS-based sensor could have widespread sub-surface detection applications.

Jain, Jinesh [NETL Site Support Contractor, Nation↗