Search NASA⌕ Search

SEARCH · Search NASA

Results for “image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Toward the Development of Group III-V Photodetectors and Imaging Arrays

A collaboration between researchers at NASA Goddard Space Flight Center (GSFC) (Code 718.1) and the Johns Hopkins University Applied Physics Laboratory (APL) on the development of gallium nitride (GaN) based photodetectors has been in existence since July 1994. This collaboration, based on APL undertaking the material growth and GSFC undertaking the device processing, has led to discrete GaN photoconductive detectors with superior characteristics to those of similar devices reported in the literature and, more recently, to the development of state-of-the art 256x256 imaging arrays with the pixels indium bump-bonded to a silicon readout circuit (RIOC). The object of this proposal is to continue the collaboration for the period 1998-2002 by outlining a program of work at the APL on the metalorganic chemical vapor deposition (MOCVD) growth of GaN and related materials for UV detector applications. In particular, emphasis will be placed on the optimization of growth on 2 in diameter substrates, on the growth of In(sub x)Ga(1-x)N and Al(sub x)Ga(1-x)N alloy structures to produce devices with a wider range of tailored cut-off wavelengths, and on the growth of pn-junction structures for photovoltaic devices.

Wickenden, Dennis K.↗

Optimization of energy window for {sup 90}Y bremsstrahlung SPECT imaging for detection tasks using the ideal observer with model-mismatch

Purpose: In yttrium-90 ({sup 90}Y) microsphere brachytherapy (radioembolization) of unresectable liver cancer, posttherapy {sup 90}Y bremsstrahlung single photon emission computed tomography (SPECT) has been used to document the distribution of microspheres in the patient and to help predict potential side effects. The energy window used during projection acquisition can have a significant effect on image quality. Thus, using an optimal energy window is desirable. However, there has been great variability in the choice of energy window due to the continuous and broad energy distribution of {sup 90}Y bremsstrahlung photons. The area under the receiver operating characteristic curve (AUC) for the ideal observer (IO) is a widely used figure of merit (FOM) for optimizing the imaging system for detection tasks. The IO implicitly assumes a perfect model of the image formation process. However, for {sup 90}Y bremsstrahlung SPECT there can be substantial model-mismatch (i.e., difference between the actual image formation process and the model of it assumed in reconstruction), and the amount of the model-mismatch depends on the energy window. It is thus important to account for the degradation of the observer performance due to model-mismatch in the optimization of the energy window. The purpose of this paper is to optimize the energy window for {sup 90}Y bremsstrahlung SPECT for a detection task while taking into account the effects of the model-mismatch. Methods: An observer, termed the ideal observer with model-mismatch (IO-MM), has been proposed previously to account for the effects of the model-mismatch on IO performance. In this work, the AUC for the IO-MM was used as the FOM for the optimization. To provide a clinically realistic object model and imaging simulation, the authors used a background-known-statistically and signal-known-statistically task. The background was modeled as multiple compartments in the liver with activity parameters independently following a Gaussian distribution; the signal was modeled as a tumor with a Gaussian-distributed activity parameter located randomly with equal probability at one of three positions. The IO test statistics (i.e., likelihood ratios) were estimated using Markov-chain Monte Carlo methods. The authors realistically modeled human anatomy using a digital phantom code, and realistically simulated {sup 90}Y bremsstrahlung SPECT imaging with a clinical SPECT system and typical imaging parameters using a previously validated Monte Carlo bremsstrahlung simulation method. Model-mismatch was included by modeling image formation process in the calculation of IO test statistics using an analytic modeling method previously developed for quantitative {sup 90}Y bremsstrahlung SPECT. To demonstrate the effects of the model-mismatch on the detection task, the authors optimized the energy window both with and without model-mismatch included in the IO. Results: For all the energy windows, the AUC values for the IO-MM were smaller than that for the IO. The optimal windows for the IO-MM and the IO were 80-180 and 60-400 keV, respectively. Conclusions: The authors have demonstrated the degradation of the ideal performance due to model-mismatch and optimized the energy window for {sup 90}Y bremsstrahlung SPECT for detection tasks by accounting for the effects of the model-mismatch. The obtained optimal window was much narrower when taking into account the model-mismatch and similar to that obtained previously for estimation tasks.

61 RADIATION PROTECTION AND DOSIMETRY↗

A NEW RAYTRACER FOR MODELING AU-SCALE IMAGING OF LINES FROM PROTOPLANETARY DISKS

The material that formed the present-day solar system originated in feeding zones in the inner solar nebula located at distances within approx20 AU from the Sun, known as the planet-forming zone. Meteoritic and cometary material contain abundant evidence for the presence of a rich and active chemistry in the planet-forming zone during the gas-rich phase of solar system formation. It is a natural conjecture that analogs can be found among the zoo of protoplanetary disks around nearby young stars. The study of the chemistry and dynamics of planet formation requires: (1) tracers of dense gas at 100-1000 K and (2) imaging capabilities of such tracers with 5-100 mas (0.5-20 AU) resolution, corresponding to the planet-forming zone at the distance of the closest star-forming regions. Recognizing that the rich infrared (2-200 mum) molecular spectrum recently discovered to be common in protoplanetary disks represents such a tracer, we present a new general ray-tracing code, RADLite, that is optimized for producing infrared line spectra and images from axisymmetric structures. RADLite can consistently deal with a wide range of velocity gradients, such as those typical for the inner regions of protoplanetary disks. The code is intended as a back-end for chemical and excitation codes, and can rapidly produce spectra of thousands of lines for grids of models for comparison with observations. Such radiative transfer tools will be crucial for constraining both the structure and chemistry of planet-forming regions, including data from current infrared imaging spectrometers and extending to the Atacama Large Millimeter Array and the next generation of Extremely Large Telescopes, the James Webb Space Telescope and beyond.

79 ASTRONOMY AND ASTROPHYSICS↗

Multifrequency Models of Black Hole Photon Rings from Low-luminosity Accretion Disks

Images of black holes encode both astrophysical and gravitational properties. Detecting highly lensed features in images can differentiate between these two effects. We present an accretion disk emission model coupled to the Adaptive Analytical Ray Tracing (AART) code that allows a fast parameter space exploration of black hole photon ring images produced from synchrotron emission from 10 to 670 GHz. As an application, we systematically study several disk models and compute their total flux density, average radii, and optical depth. The model parameters are chosen around fiducial values calibrated to general relativistic magnetohydrodynamic (GRMHD) simulations and observations of M87*. For the parameter space studied, we characterize the transition between optically thin and thick regimes and the frequency at which the first photon ring is observable. Our results highlight the need for careful definitions of photon ring radius in the image domain, as in certain models the highly lensed photon ring is dimmer than the direct emission at certain angles. We find that at low frequencies the ring radii are set by the electron temperature, while at higher frequencies the magnetic field strength plays a more significant role, demonstrating how multifrequency analysis can also be used to infer plasma parameters. Lastly, we show how our implementation can qualitatively reproduce multifrequency black hole images from GRMHD simulations when adding time variability to our disk model through Gaussian random fields. This approach provides a new method for simulating observations from the Event Horizon Telescope and the proposed Black Hole Explorer space mission.

79 ASTRONOMY AND ASTROPHYSICS↗

Preliminary analysis of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) for mineralogic mapping at sites in Nevada and Colorado

Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data for sites in Nevada and Colorado were evaluated to determine their utility for mineralogical mapping in support of geologic investigations. Equal energy normalization is commonly used with imaging spectrometer data to reduce albedo effects. Spectra, profiles, and stacked, color-coded spectra were extracted from the AVIRIS data using an interactive analysis program (QLook) and these derivative data were compared to Airborne Imaging Spectrometer (AIS) results, field and laboratory spectra, and geologic maps. A feature extraction algorithm was used to extract and characterize absorption features from AVIRIS and laboratory spectra, allowing direct comparison of the position and shape of absorption features. Both muscovite and carbonate spectra were identified in the Nevada AVIRIS data by comparison with laboratory and AIS spectra, and an image was made that showed the distribution of these minerals for the entire site. Additional, distinctive spectra were located for an unknown mineral. For the two Colorado sites, the signal-to-noise problem was significantly worse and attempts to extract meaningful spectra were unsuccessful. Problems with the Colorado AVIRIS data were accentuated by the IAR reflectance technique because of moderate vegetation cover. Improved signal-to-noise and alternative calibration procedures will be required to produce satisfactory reflectance spectra from these data. Although the AVIRIS data were useful for mapping strong mineral absorption features and producing mineral maps at the Nevada site, it is clear that significant improvements to the instrument performance are required before AVIRIS will be an operational instrument.

Kruse, Fred A.↗

Spatiotemporal evolution of runaway electrons from synchrotron images in Alcator C-Mod

We report in the Alcator C-Mod tokamak, relativistic runaway electron (RE) generation can occur during the flattop current phase of low density, diverted plasma discharges. Due to the high toroidal magnetic field (B 0 = 5.4 T), RE synchrotron radiation is measured by a wide-view camera in the visible wavelength range (λ ≈ 400–900 nm). In this paper, a statistical analysis of over one thousand camera images is performed to investigate the plasma conditions under which synchrotron emission is observed in C-Mod. In addition, the spatiotemporal evolution of REs during one particular discharge is explored in detail via a thorough analysis of the distortion-corrected synchrotron images. To accurately predict RE energies, the kinetic solver CODE is used to evolve the electron momentum-space distribution at six locations throughout the plasma: the magnetic axis and flux surfaces q = 1, 4/3, 3/2, 2, and 3. These results, along with the experimentally-measured magnetic topology and camera geometry, are input into the synthetic diagnostic SOFT to simulate synchrotron emission and detection. Interesting spatial structure near the surface q = 2 is found to coincide with the onset of a locked mode and increased MHD activity. Furthermore, the RE density profile evolution is fit by comparing experimental to synthetic images, providing important insight into RE spatiotemporal dynamics.

synthetic diagnostic↗

A gallery of HCMM images

A gallery of what might be called the ""Best of HCMM'' imagery is presented. These 100 images, consisting mainly of Day-VIS, Day-IR, and Night-IR scenes plus a few thermal inertia images, were selected from the collection accrued in the Missions Utilization Office (Code 902) at the Goddard Space Flight Center. They were selected because of both their pictorial quality and their information or interest content. Nearly all the images are the computer processed and contrast stretched products routinely produced by the image processing facility at GSFC. Several LANDSAT images, special HCMM images made by HCMM investigators, and maps round out the input.

Source record↗

Accuracy of cranial coplanar beam therapy using an oblique, stereoscopic x-ray image guidance system

A system for measuring two-dimensional (2D) dose distributions in orthogonal anatomical planes in the cranium was developed and used to evaluate the accuracy of coplanar conformal therapy using ExacTrac image guidance. Dose distributions were measured in the axial, sagittal, and coronal planes using a CIRS (Computerized Imaging Reference Systems, Inc.) anthropomorphic head phantom with a custom internal film cassette. Sections of radiographic Kodak EDR2 film were cut, processed, and digitized using custom templates. Spatial and dosimetric accuracy and precision of the film system were assessed. BrainScan planned a coplanar-beam treatment to conformally irradiate a 2-cm-diameterx2-cm-long cylindrical planning target volume. Prior to delivery, phantom misalignments were imposed in combinations of {+-}8 mm offsets in each of the principal directions. ExacTrac x-ray correction was applied until the phantom was within an acceptance criteria of 1 mm/1 deg. (first two measurement sets) or 0.4 mm/0.4 deg. (last two measurement sets). Measured dose distributions from film were registered to the treatment plan dose calculations and compared. Alignment errors, displacement between midpoints of planned and measured 70% isodose contours ({delta}c), and positional errors of the 80% isodose line were evaluated using 49 2D film measurements (98 profiles). Comparison of common, but independent measurements of {delta}c showed that systematic errors in the measurement technique were 0.2 mm or less along all three anatomical axes and that random error averaged ({sigma}{+-}{sigma}{sub {sigma}}) 0.29{+-}0.06 mm for the acceptance criteria of 1 mm/1 deg. and 0.15{+-}0.02 mm for the acceptance criteria of 0.4 mm/0.4 deg. . The latter was consistent with independent estimates that showed the precision of the measurement system was 0.3 mm (2{sigma}). Values of {delta}c were as great as 0.9, 0.3, and 1.0 mm along the P-A, R-L, and I-S axes, respectively. Variations in {delta}c along the P-A axis were correlated to misalignments between laser isocenter and radiation isocenter as documented by daily clinical Lutz tests. Based on results of comparisons of measured with calculated positions of the 80% dose lines along the major anatomical axes, a 1.25, 1.0, and 1.0 mm (0.75, 0.5, and 0.25 mm) gross tumor volume (GTV)-planning target volume (PTV) margin to account for delivery error would be appropriate for the P-A, R-L, and I-S axes, respectively, for an acceptance criteria of 1 mm/1 deg. (0.4 mm/0.4 deg. ). It typically took 2 (3) ExacTrac x-ray image sets to achieve and verify acceptance criteria of 1 mm/1 deg. (0.4 mm/0.4 deg. ). Our results demonstrated a measurement technique using a CIRS anthropomorphic head phantom with a modified film cassette, radiographic film (Kodak EDR2) with a custom film cutting template, and film dosimetry software has been developed and successfully applied to our clinic. It is recommended that a third party offer this service. Our goal of achieving accuracy of delivery of 1 mm or better in each of the three major anatomical axes was almost, but not quite achieved, not because of the accuracy of the image guidance system, but likely due to inaccuracy of laser isocenter and other systematic errors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-I-11: Software Development for 4D-CBCT Research of Real-Time-Image Gated Spot Scanning Proton Therapy

Purpose: To acquire correct information for inside the body in patient positioning of Real-time-image Gated spot scanning Proton Therapy (RGPT), utilization of tomographic image at exhale phase of patient respiration obtained from 4-dimensional Cone beam CT (4D-CBCT) has been desired. We developed software named “Image Analysis Platform” for 4D-CBCT researches which has technique to segment projection-images based on 3D marker position in the body. The 3D marker position can be obtained by using two axes CBCT system at Hokkaido University Hospital Proton Therapy Center. Performance verification of the software was implemented. Methods: The software calculates 3D marker position retrospectively by using matching positions on pair projection-images obtained by two axes fluoroscopy mode of CBCT system. Log data of 3D marker tracking are outputted after the tracking. By linking the Log data and gantry-angle file of projection-image, all projection-images are equally segmented to spatial five-phases according to marker 3D position of SI direction and saved to specified phase folder. Segmented projection-images are used for CBCT reconstruction of each phase. As performance verification of the software, test of segmented projection-images was implemented for sample CT phantom (Catphan) image acquired by two axes fluoroscopy mode of CBCT. Dummy marker was added on the images. Motion of the marker was modeled to move in 3D space. Motion type of marker is sin4 wave function has amplitude 10.0 mm/5.0 mm/0 mm, cycle 4 s/4 s/0 s for SI/AP/RL direction. Results: The marker was tracked within 0.58 mm accuracy in 3D for all images, and it was confirmed that all projection-images were segmented and saved to each phase folder correctly. Conclusion: We developed software for 4D-CBCT research which can segment projection-image based on 3D marker position. It will be helpful to create high quality of 4D-CBCT reconstruction image for RGPT.

60 APPLIED LIFE SCIENCES↗

CHARACTERIZATION OF THE INNER DISK AROUND HD 141569 A FROM KECK/NIRC2 L-BAND VORTEX CORONAGRAPHY

HD 141569 A is a pre-main sequence B9.5 Ve star surrounded by a prominent and complex circumstellar disk, likely still in a transition stage from protoplanetary to debris disk phase. Here, we present a new image of the third inner disk component of HD 141569 A made in the L ′ band (3.8 μ m) during the commissioning of the vector vortex coronagraph that has recently been installed in the near-infrared imager and spectrograph NIRC2 behind the W.M. Keck Observatory Keck II adaptive optics system. We used reference point-spread function subtraction, which reveals the innermost disk component from the inner working distance of ≃23 au and up to ≃70 au. The spatial scale of our detection roughly corresponds to the optical and near-infrared scattered light, thermal Q , N , and 8.6 μ m PAH emission reported earlier. We also see an outward progression in dust location from the L ′ band to the H band (Very Large Telescope/SPHERE image) to the visible ( Hubble Space Telescope ( HST )/STIS image), which is likely indicative of dust blowout. The warm disk component is nested deep inside the two outer belts imaged by HST-NICMOS in 1999 (at 406 and 245 au, respectively). We fit our new L ′-band image and spectral energy distribution of HD 141569 A with the radiative transfer code MCFOST. Our best-fit models favor pure olivine grains and are consistent with the composition of the outer belts. While our image shows a putative very faint point-like clump or source embedded in the inner disk, we did not detect any true companion within the gap between the inner disk and the first outer ring, at a sensitivity of a few Jupiter masses.

79 ASTRONOMY AND ASTROPHYSICS↗

Spatiotemporal evolution of runaway electrons from synchrotron images in Alcator C-Mod

In the Alcator C-Mod tokamak, relativistic runaway electron (RE) generation can occur during the flattop current phase of low density, diverted plasma discharges. Due to the high toroidal magnetic field (B0 = 5.4 T), RE synchrotron radiation is measured by a wide-view camera in the visible wavelength range (~400-900 nm). In this paper, a statistical analysis of over one thousand camera images is performed to investigate the plasma conditions under which synchrotron emission is observed in C-Mod. In addition, the spatiotemporal evolution of REs during one particular discharge is explored in detail via a thorough analysis of the distortion-corrected synchrotron images. To accurately predict RE energies, the kinetic solver CODE [Landreman et al 2014 Comput. Phys. Commun. 185 847-855] is used to evolve the electron momentum-space distribution at six locations throughout the plasma: the magnetic axis and flux surfaces q = 1, 4/3, 3/2, 2, and 3. These results, along with the experimentally-measured magnetic topology and camera geometry, are input into the synthetic diagnostic SOFT [Hoppe et al 2018 Nucl. Fusion 58 026032] to simulate synchrotron emission and detection. Interesting spatial structure near the surface q = 2 is found to coincide with the onset of a locked mode and increased MHD activity. Furthermore, the RE density profile evolution is fit by comparing experimental to synthetic images, providing important insight into RE spatiotemporal dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Verification and validation of linear gyrokinetic simulation of Alfven eigenmodes in the DIII-D tokamak

A verification and validation study is carried out for a sequence of reversed shear Alfven instability time slices. The mode frequency increases in time as the minimum (q{sub min}) in the safety factor profile decreases. Profiles and equilibria are based upon reconstructions of DIII-D discharge (no. 142111) in which many such frequency up-sweeping modes were observed. Calculations of the frequency and mode structure evolution from two gyrokinetic codes, GTC and GYRO, and a gyro-Landau fluid code TAEFL are compared. The experimental mode structure of the instability was measured using time-resolved two-dimensional electron cyclotron emission imaging. The three models reproduce the frequency upsweep event within {+-}10% of each other, and the average of the code predictions is within {+-}8% of the measurements; growth rates are predicted that are consistent with the observed spectral line widths. The mode structures qualitatively agree with respect to radial location and width, dominant poloidal mode number, ballooning structure, and the up-down asymmetry, with some remaining differences in the details. Such similarities and differences between the predictions of the different models and the experimental results are a valuable part of the verification/validation process and help to guide future development of the modeling efforts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using an EPID for patient-specific VMAT quality assurance

Purpose: A patient-specific quality assurance (QA) method was developed to verify gantry-specific individual multileaf collimator (MLC) apertures (control points) in volumetric modulated arc therapy (VMAT) plans using an electronic portal imaging device (EPID). Methods: VMAT treatment plans were generated in an Eclipse treatment planning system (TPS). DICOM images from a Varian EPID (aS1000) acquired in continuous acquisition mode were used for pretreatment QA. Each cine image file contains the grayscale image of the MLC aperture related to its specific control point and the corresponding gantry angle information. The TPS MLC file of this RapidArc plan contains the leaf positions for all 177 control points (gantry angles). In-house software was developed that interpolates the measured images based on the gantry angle and overlays them with the MLC pattern for all control points. The 38% isointensity line was used to define the edge of the MLC leaves on the portal images. The software generates graphs and tables that provide analysis for the number of mismatched leaf positions for a chosen distance to agreement at each control point and the frequency in which each particular leaf mismatches for the entire arc. Results: Seven patients plans were analyzed using this method. The leaves with the highest mismatched rate were found to be treatment plan dependent. Conclusions: This in-house software can be used to automatically verify the MLC leaf positions for all control points of VMAT plans using cine images acquired by an EPID.

61 RADIATION PROTECTION AND DOSIMETRY↗

BFSVBF (BatFinder Smart Video BioFilter) [SWR-22-87] and Multi-class BatFinder Smart Video BioFilter Keras

Bats are notoriously difficult to study, therefore, identifying specific behavioral trends and the precise environmental conditions at the time of collision requires a monitoring solution that can reliably collect relevant data. To date, thermal infrared video surveillance has been extensively applied to study bats and has proven to be a powerful yet cumbersome tool. Current analytical approaches are time consuming because data processing data has not been fully automated. In the past, steps have been taken to record avian and bat activity in conjunction with complicated image processing techniques that separate species from other moving objects within the field of view (i.e. clouds and portions of the wind turbine). Once the videos are collected, the post-processing does not allow real time monitoring and identification, leading to a delay in both studying the behavior of these species and determining the effectiveness of any impact reduction strategy being studied. Moreover, object identification capability is lacking, thus limiting the usefulness of video data. To resolve these issues, we are using open source computer vision and machine learning techniques allowing for automatic detection of objects in real-time with the ability to correlate these objects with environmental variables and recording the flight paths of each object. The code has gone through five rounds of development with images used to train the models. This advancement allows for automated real-time data collection, identification, and tracking, thereby eliminating the need for long and tedious post-analysis processing of the videos. We will discuss the two open source and publicly available machine learning models developed within this scope of this work: 1) a binary model with a 97.5% accuracy in identifying the difference between an object and an empty scene, including wind turbine and clouds; and 2) a multiple classification model with the capability of identifying the type of object detected: bats (90% accuracy), birds (83% accuracy), insects (69% accuracy) and non-biological (99% accuracy).

Yarbrough, John↗

Panchromatic Imaging of a Transitional Disk: The Disk of GM AUR in Optical and FUV Scattered Light

We have imaged GM Aurigae with the Hubble Space Telescope, detected its disk in scattered light at 1400 and 1650 A, and compared these with observations at 3300 A, 5550 A, 1.1 micron, and 1.6 micron. The scattered light increases at shorter wavelengths. The radial surface brightness profile at 3300 A shows no evidence of the 24 au radius cavity that has been previously observed in submillimeter observations. Comparison with dust grain opacity models indicates that the surface of the entire disk is populated with submicron grains. We have compiled a spectral energy distribution from 0.1 micron to 1 mm and used it to constrain a model of the star + disk system that includes the submillimeter cavity using the Monte Carlo radiative transfer code by Barbara Whitney. The best-fit model image indicates that the cavity should be detectable in the F330W bandpass if the cavity has been cleared of both large and small dust grains, but we do not detect it. The lack of an observed cavity can be explained by the presence of submicron grains interior to the submillimeter cavity wall. We suggest one explanation for this that could be due to a planet of mass less than 9M(sub J) interior to 24 au. A unique cylindrical structure is detected in the far- UV data from the Advanced Camera for Surveys/Solar Blind Channel. It is aligned along the system semiminor axis, but does not resemble an accretion-driven jet. The structure is limb brightened and extends 190 +/- 35 au above the disk midplane. The inner radius of the limb brightening is 40 +/- 10 au, just beyond the submillimeter cavity wall.

circumstellar matter aEuro" protoplanetary disks a↗

PANCHROMATIC IMAGING OF A TRANSITIONAL DISK: THE DISK OF GM AUR IN OPTICAL AND FUV SCATTERED LIGHT

We have imaged GM Aurigae with the Hubble Space Telescope , detected its disk in scattered light at 1400 and 1650 Å, and compared these with observations at 3300 Å, 5550 Å, 1.1 μ m, and 1.6 μ m. The scattered light increases at shorter wavelengths. The radial surface brightness profile at 3300 Å shows no evidence of the 24 au radius cavity that has been previously observed in submillimeter observations. Comparison with dust grain opacity models indicates that the surface of the entire disk is populated with submicron grains. We have compiled a spectral energy distribution from 0.1 μ m to 1 mm and used it to constrain a model of the star + disk system that includes the submillimeter cavity using the Monte Carlo radiative transfer code by Barbara Whitney. The best-fit model image indicates that the cavity should be detectable in the F330W bandpass if the cavity has been cleared of both large and small dust grains, but we do not detect it. The lack of an observed cavity can be explained by the presence of submicron grains interior to the submillimeter cavity wall. We suggest one explanation for this that could be due to a planet of mass <9 M {sub J} interior to 24 au. A unique cylindrical structure is detected in the far-UV data from the Advanced Camera for Surveys/Solar Blind Channel. It is aligned along the system semiminor axis, but does not resemble an accretion-driven jet. The structure is limb brightened and extends 190 ± 35 au above the disk midplane. The inner radius of the limb brightening is 40 ± 10 au, just beyond the submillimeter cavity wall.

79 ASTRONOMY AND ASTROPHYSICS↗

HipGISAXS : a high-performance computing code for simulating grazing-incidence X-ray scattering data

This article describes the development of a flexible grazing-incidence small-angle X-ray scattering (GISAXS) simulation code in the framework of the distorted wave Born approximation that effectively utilizes the parallel processing power provided by graphics processors and multicore processors. The code, entitled High-Performance GISAXS , computes the GISAXS image for any given superposition of user-defined custom shapes or morphologies in a material and for various grazing-incidence angles and sample orientations. These capabilities permit treatment of a wide range of possible sample structures, including multilayered polymer films and nanoparticles on top of or embedded in a substrate or polymer film layers. In cases where the material displays regions of significant refractive index contrast, an algorithm has been implemented to perform a slicing of the sample and compute the averaged refractive index profile to be used as the reference geometry of the unperturbed system. A number of case studies are presented, which demonstrate good agreement with the experimental data for a variety of polymer and hybrid polymer/nanoparticle composite materials. The parallelized simulation code is well suited for addressing the analysis efforts required by the increasing amounts of GISAXS data being produced by high-speed detectors and ultrafast light sources.

Chemistry↗

SU-E-J-08: Comparison of Unintended Radiation Doses to Organs at Risk Resulting From the Out-Of-Field Therapeutic Beams and From Image-Guidance X-Ray Procedures

Purpose: The unintended radiation dose to organs at risk (OAR) can be contributed from imaging guidance procedures as well as from leakage and scatter of therapeutic beams. This study compares the imaging dose with the unintended out-of-field therapeutic dose to patient sensitive organs. Methods: The Monte Carlo EGSnrc user codes, BEAMnrc and DOSXYZnrc, were used to simulate kV X-ray sources from imaging devices as well as the therapeutic IMRT/VMAT beams and to calculate doses to target and OARs on patient treatment planning CT images. The accuracy of the Monte Carlo simulations was benchmarked against measurements in phantoms. The dose-volume histogram was utilized in analyzing the patient organ doses. Results: The dose resulting from Standard Head kV-CBCT scans to bone and soft tissues ranges from 0.7 to 1.1 cGy and from 0.03 to 0.3 cGy, respectively. The dose resulting from Thorax scans on the chest to bone and soft tissues ranges from 1.1 to 1.8 cGy and from 0.3 to 0.6 cGy, respectively. The dose resulting from Pelvis scans on the abdomen to bone and soft tissues range from 3.2 to 4.2 cGy and from 1.2 to 2.2 cGy, respectively. The out-of-field doses to OAR are sensitive to the distance between the treated target and the OAR. For a typical Head-and-Neck IMRT/VMAT treatment the out-of-field doses to eyes are 1–3% of the target dose, or 2–6 cGy per fraction. Conclusion: The imaging doses to OAR are predictable based on the imaging protocols used when OARs are within the imaged volume and can be estimated and accounted for by using tabulated values. The unintended out-of-field doses are proportional to the target dose, strongly depend on the distance between the treated target and OAR, and are generally higher comparing to the imaging dose. This work was partially supported by Varian research grant VUMC40590.

60 APPLIED LIFE SCIENCES↗