Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization efficiency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Cesium control and diagnostics in surface plasma negative ion sources

For efficient and reliable negative ion generation it is very important to improve a cesium control and diagnostics. Laser beam attenuation and resonance fluorescence can be used for measurement of cesium distribution and cesium control. Resonant laser excitation and two-photon excitation can be used for improved cesium ionization and cesium trapping in the discharge chamber. Simple and inexpensive diode lasers can be used for cesium diagnostics and control. Cesium migration along the surface is an important mechanism of cesium escaping. It is important to develop a suppression of cesium migration and cesium accumulation on the extraction system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evidence for ionization damage in mid-wave infrared nBn detectors

The effects of 63 MeV proton and 60Co gamma irradiation on the operation of 4.3 μm cutoff nBn photodetectors are demonstrated separately, and both are shown to yield a total ionizing dose (TID) effect. The effect is shown here in an InAsSbBi nBn detector and has been observed in other bulk alloy nBn detectors, and is unusual as it is notably absent in superlattice nBn detectors. The non-antireflection coated detectors exhibit a pre-radiation quantum efficiency of 17% at 3.3 μm wavelength and a dark current density of 50 μA/cm2, or roughly 300× the Rule 07 expectation, at their ideal operating voltage of −0.4 V bias at 150 K. Step-wise proton irradiation and in situ measurement indicate that the dark current increases to about 400× Rule 07 at the highest proton dose level of 150 krad(Si) (9.10 × 1011 p+/cm2), while the quantum efficiency is degraded at a relatively faster rate than the majority of analogous detectors characterized by our lab. Both the photocurrent and dark current are also shown to exhibit a turn-on voltage magnitude reduction of 100 mV following either gamma or proton irradiation, a trend which is attributable to negative trapped charge at the barrier interface (TID effect). This theory is further supported by an observed capacitance density magnitude reduction with dose and affirmed with Silvaco TCAD simulations. Following both proton exposure and subsequent anneal and gamma exposure and subsequent anneal; dark current, photocurrent, and CV all approach their pre-radiation baseline values.

Physics↗

First direct measurement of resonance strengths in {sup 17}O({alpha},{gamma}){sup 21}Ne

The reaction {sup 17}O({alpha},{gamma}){sup 21}Ne has been measured by in-beam {gamma} spectroscopy for the first time in the energy range E{sub {alpha}=}750-1650 keV using highly enriched anodized Ta{sub 2}({sup 17}O){sub 5} targets. Resonances were found at E{sub {alpha}=} 1002, 1386, and 1619 keV. Their strengths and primary {gamma}-ray branchings are given. The new results exclude the low reaction rate of Descouvemont and support the rate of Caughlan and Fowler. Implications for the neutron poisoning efficiency of {sup 16}O in the weak s-process are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for heavy Majorana neutrinos in pp collisions at √s = 8 TeV with the CMS detector & photodetector and calorimeter R&D for particle colliders

This thesis contains both physics analysis and hardware studies. It consists of two primary sections: the results of a search for heavy Majorana mass neutrinos, using the event signature of same (like) sign charged electron pairs ($e^{\pm} e^{\pm}$ ) and two jets, and the results of studies to upgrade the Hadronic Forward (HF) and Hadronic Endcap (HE) subdetectors in the Compact Muon Solenoid (CMS) detector in response to the high intensity proton-proton collisions generated at the Large Hadron Collider (LHC) at European Organization for Nuclear Research (CERN, Conseil Europ\'{e}en pour la Recherche Nucl\'{e}aire). In this search for Majorana mass neutrinos, same sign dielectron ($e^{\pm} e^{\pm}$) + dijet events in the final state have been considered as a signature for neutrino particles. The analyzed data corresponds to an integrated luminosity of 19.7 fb\textsuperscript{-1} of proton-proton collisions at a center of mass energy of $\sqrt{s} = 8 \text{TeV}$, collected using the CMS detector during the 2012 operation at the LHC. Monte Carlo simulations accounting for the theoretical expectations of the Standard Model (SM) and the detector limitations are used to prototype the experiment and to test proposed analysis steps. No excess of events is observed in the data beyond the expected SM background. Upper limits are set on the mixing element squared, $|{V}_{eN}|^{2}$, of the heavy Majorana neutrino with standard model neutrinos, as a function of Majorana neutrino mass for masses in the range of 40-500 $GeV/c^2$. The detector upgrade search comprises three sections of this thesis. The first section describes the test results of 1785 multianode Hamamatsu R7600U-200-M4 photomultiplier tubes (PMT) in numerous parameters such as gain, dark current, and timing characteristics, which provide insights on the expected performance of the upgraded CMS-HF detector. These PMTs replaced the previous single anode R7525 PMTs because the glass windows of previous PMTs are the source of Cherenkov radiation, which causes a background noise in the experiment. The second section reports characterization results of two types of PMTs in a novel operation mode for Secondary Emission (SE) Ionization Calorimetry, which is a novel technique to measure electromagnetic shower particles in extreme radiation environments. The third section presents the test results of novel scintillating materials for CMS experiment in specific and future particle accelerators in general. These materials are Polyethylene Naphthalate (PEN), Polyethylene Terephthalate (PET), high efficiency mirror (HEM) and quartz plates with various organic and inorganic coating materials such as p-Terphenyl (pTp), Anthracene and Gallium-doped Zinc Oxide (ZnO:Ga). We have investigated them for radiation hardness, light yield, timing characteristics, and scintillation and transmission properties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Capillary Isotachophoresis-Nanoelectrospray Ionization-Selected Reaction Monitoring MS via a Novel Sheathless Interface for High Sensitivity Sample Quantification

A novel sheathless CITP/CZE-MS interface featuring a large i.d. separation capillary and a detachable small i.d. ESI emitter was developed in this study to simultaneously achieve large sample loading capacity and stable nanoESI operation. Crucial operating parameters, including sample loading volume, flow rate, and separation window, were systematically investigated to attain optimum CITP/CZE separation efficiency and MS detection sensitivity. The performance of CITP/CZE-nanoESI-MS using the new sheathless interface was evaluated for its achievable low limit of quantitation (LOQ) by analyzing targeted peptides, leu-enkephalin and angiotensin II, spiked in a BSA tryptic digest matrix at different concentrations. A linear dynamic range spanning 4.5 orders of magnitude and a 10 pM LOQ with excellent measurement reproducibility were obtained experimentally for both targeted peptides, representing a 5-fold sensitivity improvement as compared to using the sheath liquid interface developed previously.

Environmental Molecular Sciences Laboratory↗

EFFICIENT COSMIC RAY ACCELERATION, HYDRODYNAMICS, AND SELF-CONSISTENT THERMAL X-RAY EMISSION APPLIED TO SUPERNOVA REMNANT RX J1713.7-3946

We model the broadband emission from supernova remnant (SNR) RX J1713.7-3946 including, for the first time, a consistent calculation of thermal X-ray emission together with non-thermal emission in a nonlinear diffusive shock acceleration model. Our model tracks the evolution of the SNR including the plasma ionization state between the forward shock and the contact discontinuity. We use a plasma emissivity code to predict the thermal X-ray emission spectrum assuming the initially cold electrons are heated either by Coulomb collisions with the shock-heated protons (the slowest possible heating), or come into instant equilibration with the protons. For either electron heating model, electrons reach {approx}>10{sup 7} K rapidly and the X-ray line emission near 1 keV is more than 10 times as luminous as the underlying thermal bremsstrahlung continuum. Since recent Suzaku observations show no detectable line emission, this places strong constraints on the unshocked ambient medium density and on the relativistic electron-to-proton ratio. For the uniform circumstellar medium (CSM) models that we consider, the low densities and high relativistic electron-to-proton ratios required to match the Suzaku X-ray observations definitively rule out pion decay as the emission process producing GeV-TeV photons. We show that leptonic models, where inverse-Compton scattering against the cosmic background radiation dominates the GeV-TeV emission, produce better fits to the broadband thermal and non-thermal observations in a uniform CSM.

79 ASTRONOMY AND ASTROPHYSICS↗

Poplar Genomics: State of the Science

Populus has become a model for genomics research in woody perennial plants due to the release of its genome sequence and the important roles it has been playing in research areas related to alternative energy and climate change. Over the past five years, enormous advances have been made in both experimental and computational genomics in Populus. In the area of Populus experimental genomics, traditional genetic approaches have been advanced to the genome scale with resolution to the gene and/or single nucleotide level on the one hand, and on the other hand, the modern omics approaches have been successfully applied to analyses of gene functions, including transcriptome profiling using microarrays as well as the next-generation DNA sequencing technology, proteome analysis using matrix assisted laser desorption ionization timeof-flight mass spectrometry, and metabolome characterization using gas chromatography/timeof-flight mass spectrometry. In the area of Populus computational genomics, significant progress has been made in sequence-based discovery of predicted gene function, comparative analysis of gene families, development of online genomic databases, and studies of the evolutionary dynamics at both the gene and genome level. While exciting achievements have been obtained in Populus genomics, several challenges need to be addressed in the future: 1) better annotation of the Populus genome; 2) robust technology for large-scale gene expression analysis; 3) an efficient system for genome-wide mutagenesis; and 4) high performance computational pipelines to keep up with the pace of the rapid accumulation of data and to integrate omics data into functional systems biology platforms.

54 ENVIRONMENTAL SCIENCES↗

Performance evaluation of the SPES FEBIAD ion source

SPES (Selective Production of Exotic Species) is the Radioactive Ion Beam (RIB) facility that is currently in the installation phase at the Istituto Nazionale di Fisica Nucleare in the Laboratori Nazionali di Legnaro (LNL-INFN). The main purpose of the facility is to deliver neutron-rich radioactive beams with a range of mass between 60 and 160 amu produced as fission products originated within a Uranium Carbide (UC x ) target impinged by high energy protons (40–70 MeV). In the last few years, the SPES group and their collaborators have focused on multiple aspects: development of various ISOL targets, ion sources, a high-power beam dump, versatile Front-End designs, primary proton beam and RIB diagnostics, design of beam optic components, and remote target handling. The development and optimization of ionization sources represents one of the most important R&D activities. The collaboration between SPES and ISOLDE (CERN) groups has enabled the evaluation of the performances of a novel FEBIAD ion source taking advantage of the ISOLDE off-line Front-End. In this paper, the results of efficiency and transversal emittance measurements of the new SPES FEBIAD ion source are presented and discussed. Particular attention is dedicated to the description of the experimental setup and to the comparison of experimental data with simulation to promote the reproducibility of the experimental tests with other types of sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the silicon coated film characteristics on tungsten surface in EAST fusion device

Siliconization using 10 % SiD 4 + 90 % He assisted by ion cyclotron range of frequency discharge (ICRF) or glow discharge (GD) was performed in EAST with full tungsten (W) diverters. It was found that the coated Si film on W sample at a higher baking temperature (160 °C) was smoother than that at a lower baking temperature (60 °C). This was mainly because physically adsorbed gaseous impurities were released at a higher baker temperature. This process improved the adhesion between the film and the surface of W. An increase in the ICRF working power from 20 kW to 40 kW further increased the Si content and the film thickness by 1.5 times. The cleaning efficiency of ICRF on the surface of the W sample before siliconization was higher at 40 kW than that at 20 kW, which facilitated the removal of oxides and other compounds from the surface of W. The ratio of silicon/oxygen (Si/O) and the thickness improved considerably due to greater ionization and deposition of SiD 4 . Additionally, siliconization via GD was more uniform and 1.5 nm thicker than that via ICRF, which was because of the greater working gas pressure, coating duration, and homogeneity in GD. These results might be used as a reference for evaluating the effect of siliconization on plasma performance and its application in fusion devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved spatial resolution for spot sampling in thermal desorption atomic force microscopy – mass spectrometry via rapid heating functions

The key to advancing materials is to understand and control their structure and chemistry. However, thorough chemical characterization is challenging since existing techniques characterize only a few properties of the specimen, thereby necessitating multiple measurement platforms to acquire the necessary information. The multimodal combination of atomic force microscopy (AFM) and mass spectrometry (MS) transcends existing analytical capabilities for nanometer scale spatially resolved correlation of the chemical and physical properties of a sample surface. One such hybrid system employs heated AFM cantilevers for thermal desorption (TD) sampling of molecules from a surface and subsequent gas phase ionization and detection of the liberated species by MS. Here in this paper, we report on the use of voltage pulse trains to tailor cantilever heating such that spot sampling size was reduced and mass spectral signal was improved compared to constant voltage, static heating of the cantilever. Desorption efficiency (DE), defined as the quotient of the mass spectral signal intensity and the volume of the desorption crater, was used to judge the effectiveness of a particular tailored heating function. To guide the development and optimization of the heating functions and aid in interpreting experimental results, a 1D finite element model was developed that predicted the cantilever response to different heating functions. Three tailored heating functions that used different combinations, magnitudes, and durations of rectangular voltage pulses, were used for surface spot sampling. The resultant sampling spot size and DE were compared to the same metrics obtained with the conventional method that uses a single voltage pulse. Using a model system composed of a thin film of ink containing pigment yellow 74 as a model system, desorption craters shrunk from 2 μm, using the conventional approach, to 310 nm using the optimum tailored heating function. This same pulsed heating function produced a 381× improvement in the DE and an 8× improvement in spatial resolution compared to the conventional heating approach showing that signal/amount of material sampled was improved significantly by this new cantilever heating strategy.

36 MATERIALS SCIENCE↗

Numerical study of boundary layer separation control using magnetogasdynamic plasma actuators

In this study, an efficient, time dependent, two-dimensional Navier-Stokes numerical code for shockwave boundary layer interaction in air is developed. Nonthermal surface plasma actuation is evaluated for effective shockwave induced boundary layer separation control within supersonic inlets. Specifically, high speed magnetogasdynamic plasma actuators are of interest. In these, localized ionization is produced close to the wall surface and then the flow is accelerated using strong magnetic fields. To replicate the experiments done at large boundary layer thickness, the code is divided into time independent and time dependent regimes to significantly reduce computation time. Computational results are in good agreement with experiments in terms of the flow structure as shown by Schlieren imaging, acetone planar laser scattering, and the static pressure profile on the test section wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Coincidence ion imaging with a fast frame camera

A new time- and position-sensitive particle detection system based on a fast frame CMOS (complementary metal-oxide semiconductors) camera is developed for coincidence ion imaging. The system is composed of four major components: a conventional microchannel plate/phosphor screen ion imager, a fast frame CMOS camera, a single anode photomultiplier tube (PMT), and a high-speed digitizer. The system collects the positional information of ions from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of a PMT processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of ion spots on each camera frame with the peak heights on the corresponding time-of-flight spectrum of a PMT. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hybrid particle-in-cell simulations of electromagnetic coupling and waves from streaming burst debris

Various systems can be modeled as a point-like explosion of ionized debris into a magnetized, collisionless background plasma-including astrophysical examples, active experiments in space, and laser-driven laboratory experiments. Debris streaming from the explosion parallel to the magnetic field may drive multiple resonant and non-resonant ion-ion beam instabilities, some of which can efficiently couple the debris energy to the background and may even support the formation of shocks. We present a large-scale hybrid (kinetic ions + fluid electrons) particle-in-cell simulation, extending hundreds of ion inertial lengths from a 3D explosion, that resolves these instabilities. We show that the character of these instabilities differs notably from the 1D equivalent by the presence of unique transverse structure. Additional 2D simulations explore how the debris beam length, width, density, and speed affect debris-background coupling, with implications for the generation of quasi-parallel shocks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ionization-induced thermally activated defect-annealing process in SiC

Ionizing events can lead to panoply of irradiation effects, and in silicon carbide (SiC), they drastically modify the defect production rate or the initial density. To better comprehend this phenomenon, 6H-SiC single crystals were first predamaged using low-velocity 100-keV Fe + ions at three fluences in the range of 10 14 cm -2 to induce three different initial disorder levels peaking at values between ~0.8 and 1 (1 corresponding to full amorphization). Crystals were then submitted to swift heavy ion irradiation in the 10 13 cm -2 fluence range at both low (~100 K) and high (~770 K) temperature. Rutherford backscattering spectrometry in channeling conditions revealed that swift ions allow annealing part of the initial damage, the recovery efficiency increasing with the irradiation temperature and reaching 75% in initially severely disordered crystals. This temperature effect has been qualitatively predicted by molecular dynamics simulations. Transmission electron microscopy allowed imaging both the recovery and the difference in the microstructure of the layers irradiated at low or high temperature. Recovery cross sections are discovered to lie in the range of a few square nanometers, consistent with previously reported values. A scenario for a general, two-step annealing mechanism referred to as an ionization-activated, thermally assisted defect-annealing (IATADA) process is proposed. This mechanism rationalizes the diverse descriptions reported so far in the literature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On-Chip Spyhole Nanoelectrospray Ionization Mass Spectrometry for Sensitive Biomarker Detection in Small Volumes

A polyimide microfluidic chip with a microhole emitter (Ø 10–12 μm) created on top of a microchannel by scanning laser ablation has been designed for nanoelectrospray ionization (spyhole-nanoESI) to couple microfluidics with mass spectrometry. The spyhole-nanoESI showed higher sensitivity compared to standard ESI and microESI from the end of the microchannel. The limits of detection (LOD) for peptide with the spyhole-nanoESI MS reached 50 pM, which was 600 times lower than that with standard ESI. The present microchip emitter allows the analysis of small volumes of samples. As an example, a small cell lung cancer biomarker, neuron-specific enolase (NSE), was detected by monitoring the transition of its unique peptide with the spyhole-nanoESI MS/MS. NSE at 0.2 nM could be well identified with a signal to noise ratio (S/N) of 50, and thereby its LOD was estimated to be 12 pM. The potential application of the spyhole-nanoESI MS/MS in cancer diagnosis was further demonstrated with the successful detection of 2 nM NSE from 1 μL of human serum. Before the detection, the serum sample spiked with NSE was first depleted with immune spin column, then desalted by centrifugal filter device, and finally digested by trypsin, without any other complicated preparation steps. The concentration matched the real condition of clinical samples. In addition, the microchips can be disposable to avoid any cross contamination. The present technique provides a highly efficient way to couple microfluidics with MS, which brings additional values to various microfluidics and MS-based analysis. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

REGULATION OF BLACK HOLE WINDS AND JETS ACROSS THE MASS SCALE

We present a study of the mechanical power generated by both winds and jets across the black hole mass scale. We begin with the study of ionized X-ray winds and present a uniform analysis using Chandra grating spectra. The high-quality grating spectra facilitate the characterization of the outflow velocity, ionization, and column density of the absorbing gas. We find that the kinetic power of the winds, derived from these observed quantities, scales with increasing bolometric luminosity as log (L {sub wind,42}/C{sub v} ) = (1.58 {+-} 0.07)log (L {sub Bol,42}) - (3.19 {+-} 0.19). This suggests that supermassive black holes may be more efficient than stellar-mass black holes in launching winds, per unit filling factor, C{sub v} . If the black hole binary (BHB) and active galactic nucleus (AGN) samples are fit individually, the slopes flatten to {alpha}{sup BHB} = 0.91 {+-} 0.31 and {alpha}{sup AGN} = 0.63 {+-} 0.30 (formally consistent within errors). The broad fit and individual fits both characterize the data fairly well, and the possibility of common slopes may point to common driving mechanisms across the mass scale. For comparison, we examine jet production, estimating jet power based on the energy required to inflate local bubbles. The jet relation is log (L {sub Jet,42}) = (1.18 {+-} 0.24)log (L {sub Bondi,42}) - (0.96 {+-} 0.43). The energetics of the bubble associated with Cygnus X-1 are particularly difficult to determine, and the bubble could be a background supernova remnant. If we exclude Cygnus X-1 from our fits, then the jets follow a relation consistent with the winds, but with a higher intercept, log (L {sub Jet,42}) = (1.34 {+-} 0.50)log (L {sub Bondi,42}) - (0.80 {+-} 0.82). The formal consistency in the wind and jet scaling relations, when assuming that L {sub Bol} and L {sub Bondi} are both proxies for mass accretion rate, suggests that a common launching mechanism may drive both flows; magnetic processes, such as magnetohydrodynamics and magnetocentrifugal forces, are viable possibilities. We also examine winds that are moving at especially high velocities, v > 0.01c. These ultra-fast outflows tend to resemble the jets more than the winds in terms of outflow power, indicating that we may be observing a regime in which winds become jets. A transition at approximately L {sub Bol} Almost-Equal-To 10{sup -2} L {sub Edd} is apparent when outflow power is plotted versus Eddington fraction. At low Eddington fractions, the jet power is dominant, and at high Eddington fractions, the wind power is dominant. This study allows for the total power from black hole accretion, both mechanical and radiative, to be characterized in a simple manner and suggests possible connections between winds and jets. X-ray wind data and jet cavity data will enable stronger tests.

79 ASTRONOMY AND ASTROPHYSICS↗

IONIZED ABSORBERS AS EVIDENCE FOR SUPERNOVA-DRIVEN COOLING OF THE LOWER GALACTIC CORONA

We show that the ultraviolet absorption features, newly discovered in Hubble Space Telescope spectra, are consistent with being formed in a layer that extends a few kpc above the disk of the Milky Way. In this interface between the disk and the Galactic corona, high-metallicity gas ejected from the disk by supernova feedback can mix efficiently with the virial-temperature coronal material. The mixing process triggers the cooling of the lower corona down to temperatures encompassing the characteristic range of the observed absorption features, producing a net supernova-driven gas accretion onto the disk at a rate of a few M{sub Sun} yr{sup -1}. We speculate that this mechanism explains how the hot mode of cosmological accretion feeds star formation in galactic disks.

79 ASTRONOMY AND ASTROPHYSICS↗

Why ionizing radiation enhances surface wettability

Radiation-Induced Surface Activation is an inherent phenomenon where surfaces that are exposed to gamma irradiation are observed to undergo an increase in wettability. This increase in wettability as a result of the ionizing radiation exposure has so far been demonstrated to have a pronounced impact on Leidenfrost temperature and two-phase fluid dynamics. Test results from previous experiments have shown that incorporation of this effect on heat transfer equipment design may increase the thermal-hydraulic margin leading to higher thermal efficiency. However, the mechanism behind the increased wettability is not clearly understood. In the present work, three different materials (Zircaloy-4, 316 stainless steel, and copper) were exposed at two different dose rates with use of two different gamma irradiation facilities. A detailed surface characterization on the post-irradiated samples is carried out to understand the changes in surface chemistry, wettability and surface morphology. It is observed from the experiments that the increase in wettability upon irradiation depended on the total dose and not on the dose rate. Moreover, localized oxidation and porosity induced by radiolysis was seen to be the predominant mechanism behind increased wettability which leads to improved Leidenfrost temperature.

36 MATERIALS SCIENCE↗