Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Constraining the physical conditions in the jets of γ-ray flaring blazars using centimeter-band polarimetry and radiative transfer simulations. I. Data and models for 0420–014, OJ 287, and 1156+295

To investigate parsec-scale jet flow conditions during GeV γ-ray flares detected by the Fermi Large Angle Telescope, we obtained centimeter-band total flux density and linear polarization monitoring observations from 2009.5 through 2012.5 with the 26 m Michigan radio telescope for a sample of core-dominated blazars. We use these data to constrain radiative transfer simulations incorporating propagating shocks oriented at an arbitrary angle to the flow direction in order to set limits on the jet flow and shock parameters during flares temporally associated with γ-ray flares in 0420–014, OJ 287, and 1156+295; these active galactic nuclei exhibited the expected signature of shocks in the linear polarization data. Both the number of shocks comprising an individual radio outburst (3 and 4) and the range of the compression ratios of the individual shocks (0.5-0.8) are similar in all three sources; the shocks are found to be forward-moving with respect to the flow. While simulations incorporating transverse shocks provide good fits for 0420–014 and 1156+295, oblique shocks are required for modeling the OJ 287 outburst, and an unusually low value of the low-energy cutoff of the radiating particles' energy distribution is also identified. Our derived viewing angles and shock speeds are consistent with independent Very Long Baseline Array results. While a random component dominates the jet magnetic field, as evidenced by the low fractional linear polarization, to reproduce the observed spectral character requires that a significant fraction of the magnetic field energy is in an ordered axial component. Both straight and low pitch angle helical field lines are viable scenarios.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of Photon-Counting Detector Responsivity for Non-Linear Two-Photon Absorption Process

Sub-band absorption at 1550 nm has been demonstrated and characterized on silicon Geiger mode detectors which normally would be expected to have no response at this wavelength. We compare responsivity measurements to singlephoton absorption for wavelengths slightly above the bandgap wavelength of silicon (approx. 1100 microns). One application for this low efficiency sub-band absorption is in deep space optical communication systems where it is desirable to track a 1030 nm uplink beacon on the same flight terminal detector array that monitors a 1550 nm downlink signal for pointingcontrol. The currently observed absorption at 1550 nm provides 60-70 dB of isolation compared to the response at 1064 nm, which is desirable to avoid saturation of the detector by scattered light from the downlink laser.

Geiger mode detector↗

THE SUPER-LINEAR SLOPE OF THE SPATIALLY RESOLVED STAR FORMATION LAW IN NGC 3521 AND NGC 5194 (M51a)

We have conducted interferometric observations with the Combined Array for Research in Millimeter Astronomy (CARMA) and an on-the-fly mapping with the 45 m telescope at Nobeyama Radio Observatory (NRO45) in the CO (J = 1-0) emission line of the nearby spiral galaxy NGC 3521. Using the new combined CARMA + NRO45 data of NGC 3521, together with similar data for NGC 5194 (M51a) and archival SINGS H{alpha}, 24 {mu}m THINGS H I, and Galaxy Evolution Explorer/Far-UV (FUV) data for these two galaxies, we investigate the empirical scaling law that connects the surface density of star formation rate (SFR) and cold gas (known as the Schmidt-Kennicutt law or S-K law) on a spatially resolved basis and find a super-linear slope for the S-K law when carefully subtracting the background emissions in the SFR image. We argue that plausibly deriving SFR maps of nearby galaxies requires the diffuse stellar and dust background emission to be subtracted carefully (especially in the mid-infrared and to a lesser extent in the FUV). Applying this approach, we perform a pixel-by-pixel analysis on both galaxies and quantitatively show that the controversial result whether the molecular S-K law (expressed as {Sigma}{sub SFR{proportional_to}{Sigma}H{sub 2}{sup {gamma}}{sub H{sup 2}}) is super-linear or basically linear is a result of removing or preserving the local background. In both galaxies, the power index of the molecular S-K law is super-linear ({gamma}{sub H{sub 2}}{approx}>1.5) at the highest available resolution ({approx}230 pc) and decreases monotonically for decreasing resolution. We also find in both galaxies that the scatter of the molecular S-K law ({sigma}{sub H{sub 2}}) monotonically increases as the resolution becomes higher, indicating a trend for which the S-K law breaks down below some scale. Both {gamma}{sub H{sub 2}} and {sigma}{sub H{sub 2}} are systematically larger in M51a than in NGC 3521, but when plotted against the de-projected scale ({delta}{sub dp}), both quantities become highly consistent for the two galaxies, tentatively suggesting that the sub-kpc molecular S-K law in spiral galaxies depends only on the scale being considered, without varying among spiral galaxies. A logarithmic function {gamma}{sub H{sub 2}}=-1.1 log [{delta}{sub dp}/kpc]+1.4 and a linear relation {sigma}{sub H{sub 2}}=-0.2 [{delta}{sub dp}/kpc]+0.7 are obtained through fitting to the M51a data, which describes both galaxies impressively well on sub-kpc scales. A larger sample of galaxies with better sensitivity, resolution, and broader field of view are required to test the general applicability of these relations.

79 ASTRONOMY AND ASTROPHYSICS↗

Radially scanning magnetic probes to study local helicity injection dynamics

Two new magnetic probes have been deployed on the Pegasus spherical tokamak to study the dynamics of local helicity injection non-solenoidal plasma start-up and current drive. The magnetic radial array probe consists of 15 pickup coils (~5 × 8 mm each) that measure B z (R) over a 15 cm linear extent. The coils consist of traces embedded in a printed circuit board. Three coil designs are utilized to balance frequency response and coil sensitivity. Helmholtz coil measurements are used to measure coil and full assembly bandwidths (~2 MHz and ~200 kHz, respectively) and sensitivities (0.18/0.35/0.96 mV T -1 s). The magnetic radial scanning probe is an array of Hall effect sensors that measure field strength ( |B| 177 mT) and direction at 8 spatial points (ΔR = 1.5 cm), supporting the studies of equilibrium field structure and low-frequency (≤5 kHz) current dynamics. It uses commercial surface-mount Hall effect sensors with chip-integrated amplifiers and compensators that are mounted in a 3-D printed frame. Helmholtz coil measurements indicate negligible cross-field gain nonlinearity and provide absolute calibration of the diagnostic. Both probes are constructed as an electrostatically shielded insertable air-side assembly that mounts within a radially translatable ultrahigh vacuum assembly from an existing probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear gyrokinetic simulations of toroidal Alfvén eigenmodes in the Mega-Amp Spherical Tokamak

Linear gyrokinetic (GK) simulations using the Gyrokinetic Toroidal Code (GTC) have been performed to investigate Toroidicity-driven Alfvén Eigenmodes (TAEs) driven by the neutral beam injection (NBI) induced fast ions in the Mega-Amp Spherical Tokamak (MAST) to identify the non-perturbative and kinetic effects of thermal plasma. A specific TAE in MAST discharge 26887, with an on-axis NBI power of approximately 1.5 MW and plasma current around 800 kA, exhibited frequency chirping, and the tangential soft x-ray camera array resolved the radial mode structure peaked near |q|=1.5. Various excitation methods were used in the GTC linear simulations, illustrating this code's capability to realistically represent the mechanisms and behaviors of fast ion-driven TAEs in spherical tokamaks. The radial structures from these GK simulations closely match measurements and calculations performed using the NOVA ideal MHD code, though with the frequencies approximately 10 kHz lower, likely due to various kinetic and non-perturbative effects. The simulations measured the damping rates due to continuum damping, radiative damping, and ion Landau damping, revealing that ion Landau damping has the most significant contribution to the total damping rate of the TAE. A comparison of growth rates of TAEs excited by fast ion Maxwellian and slowing-down distributions shows that the TAEs excited by a fast ion anisotropic pitch distribution (as part of the slowing-down distributions) are more unstable compared to those excited by a Maxwellian distribution with an equivalent fast ion beta. This shows that the use of fast ion anisotropy alters the number of fast ions to be in shear Alfvén resonance, and hence, it can greatly affect the stability of TAEs. These tests can be performed with the GTC but impossible with ideal MHD simulations, highlighting the necessity of kinetic simulations such as the GTC for a precise prediction of the TAE stability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Inflatable L-Band Microstrip SAR Array

Inflatable structures have been identified as one of the enabling technologies to achieve low mass, high packaging efficiency, and reliable deployment for future NASA spaceborne synthetic aperture radar (SAR) array antennas. A current L-band SAR antenna development, with aperture size of 10 m x 3 m, is required to have the capabilities of dual-linear polarization, 80-MHz bandwidth, electronic beam scanning, and less than 100 kg of mass. An inflatable concept, which employs the inflatable tubular frame structure to support a multilayer, thin membrane, microstrip array radiating aperture, has been identified. It uses a "roll-up" concept, for deploying the thin membranes to form a planar array aperture. To demonstrate this concept, two contracts were independently given to ILC Dover, Inc. and L'Garde Corp. for each to construct a 1/3 size (3.3 m x 1.0 m) functional model with an inflatable structure at L-band frequency. JPL provided both contractors with the antenna RF design and the etched thin membranes. The ILC Dover model has been delivered to JPL and gone through a series of deployment and RF tests. This is believed to be the first inflatable array antenna ever developed. This paper presents the mechanical and electrical constructions of this inflatable array and its test results.

Huang, J.↗

No evidence for the blue-tilted power spectrum of relic gravitational waves

In this paper, we constrain the tilt of the power spectrum of relic gravitational waves by combining the data from BICEP2/Keck Array and Planck (BKP) and the Laser Interferometer Gravitational-Waves Observatory (LIGO). Supposing the linearly uniform priors for both the tensor-to-scalar ratio r and the tensor tilt n{sub t}, we find n{sub t}=0.66{sup +1.83}{sub −1.44} at the 68% confidence level from the data of BKP B-modes. By further adding the LIGO upper limit on the intensity of stochastic gravitational-wave background, the constraint becomes n{sub t}=−0.76{sup +1.37}{sub −0.52} at the 68% confidence level by assuming that the tensor amplitude has the similar order of the upper bounds from current CMB experiments. We find that there is no evidence for a blue-tilted power spectrum of relic gravitational waves and either sign of the index of tensor power spectrum is compatible with the current data.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of U 238 ( n , n ' γ ) cross section data and their impact on reaction models

A better knowledge of (n,xn) reaction cross sections is important for both reaction modeling and energy applications. This article focuses on inelastic scattering of neutrons off 238 U for which improvements are needed to better constrain evaluations and solve inconsistencies in nuclear power reactor calculations. A new precise measurement of (n,xnγ) reaction cross sections on 238 U has been performed at the GELINA (Geel Electron LINear Accelerator) neutron facility operated by EC-JRC-Geel (Belgium) with the GRAPhEME (GeRmanium array for Actinides PrEcise MEasurements) setup. The prompt γ-ray spectroscopy method coupled to time-of-flight measurements is used to extract (n,xnγ) cross section values which can be further combined to infer the total neutron inelastic scattering cross section. Cross section data for 18 γ transitions (five never measured before) are presented and compared to the data in the literature. Here, emphasis is especially given to the uncertainty determination to produce partial cross section data as accurate as possible. Due to intrinsic limitations of the experimental method, the use of additional nuclear structure information coupled with theoretical modeling is required to determine the total (n, n') cross section over the whole neutron energy range. We have investigated modeling aspects of the 238 U(n,n'γ) cross sections related to the description of compound nucleus and preequilibirum mechanisms as well as the discrete part of nuclear structure. Through comparison between experimental and calculated (n,n'γ) cross sections, we pinpoint inaccuracies in the description of specific reaction mechanisms and challenge recently implemented models. This helps improving the whole modeling of the (n, n') reaction.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DPC Disposal Thermal Scoping Analysis

This is a progress report on thermal modeling for dual-purpose canister (DPCs) direct disposal that covers several available calculation methods and addresses creep and temperature-dependent properties in a salt repository. Three modeling approaches are demonstrated: A semi-analytical calculation method that uses linear solutions with superposition and imaging, to represent a central waste package in a larger array; A finite difference model of coupled thermal creep, implemented in FLAC2D; and An integrated finite difference thermal-hydrologic modeling approach for repositories in different generic host media, implemented in PFLOTRAN. These approaches are at different levels of maturity, and future work is expected to add refinements and establish the best applications for each.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Major determinants of the biogeographic pattern of the shallow-sea fauna

The benthic shallow-sea is defined as the region of sea floor lying between the supralittoral zone at the shoreline and the impingement of the thermocline separating a warm shallow and variable portion of the water column from rather homogeneous and constant cooler waters beneath. Three types of shallow-sea provinces can be recognized: (1) one-dimensional, linear shelves; (2) two-dimensional shelves; and (3) scattered islands in two-dimensional arrays. Dispersal powers of marine invertebrates vary with developmental mode, and patterns of dispersal, endemism and speciation vary among the different provincial types. Invertebrate developmental modes vary systematically with geography, and presumably are adaptive to environmental conditions. Clades with only a single mode of development tend to be restricted to regions appropriate to that mode, significantly affecting their biogeographic patterns. The consequences of geographic and other environmental changes are reviewed.

Valentine, J. W.↗

Effects of excitation level on the stability of an axisymmetric mixing layer

The effect of various levels of excitation on the stability and development of an axisymmetric mixing layer was studied experimentally. The flow was excited axisymmetrically by a single speaker placed at the base of the plenum chamber. Measurements of mean and phase-averaged velocity profiles were made using an array of hot-wire probes. The measured profiles were compared to eigenfunctions calculated from linear, viscous stability theory. It is shown that the theoretical predictions, based on measured profiles of mean velocity, compare very well with the phase-averaged measurements, even when the local disturbance reaches levels as high as 24 percent of the jet speed. The cumulative effect of excitation on the mean flow is examined as a function of local Strouhal number as well as excitation level.

Samet, M. M.↗

Employment of CB models for non-linear dynamic analysis

The non-linear dynamic analysis of large structures is always very time, effort and CPU consuming. Whenever possible the reduction of the size of the mathematical model involved is of main importance to speed up the computational procedures. Such reduction can be performed for the part of the structure which perform linearly. Most of the time, the classical Guyan reduction process is used. For non-linear dynamic process where the non-linearity is present at interfaces between different structures, Craig-Bampton models can provide a very rich information, and allow easy selection of the relevant modes with respect to the phenomenon driving the non-linearity. The paper presents the employment of Craig-Bampton models combined with Newmark direct integration for solving non-linear friction problems appearing at the interface between the Hubble Space Telescope and its solar arrays during in-orbit maneuvers. Theory, implementation in the FEM code ASKA, and practical results are shown.

Klein, M. R. M.↗

An analysis of fiber-matrix interface failure stresses for a range of ply stress states

A graphite/bismaleimide laminate was prepared without the usual fiber treatment and was tested over a wide range of stress states to measure its ply cracking strength. These tests were conducted using off-axis flexure specimens and produced fiber-matrix interface failure data over a correspondingly wide range of interface stress states. The absence of fiber treatment, weakened the fiber-matrix interfaces and allowed these tests to be conducted at load levels that did not yield the matrix. An elastic micromechanics computer code was used to calculate the fiber-matrix interface stresses at failure. Two different fiber-array models (square and diamond) were used in these calculations to analyze the effects of fiber arrangement as well as stress state on the critical interface stresses at failure. This study showed that both fiber-array models were needed to analyze interface stresses over the range of stress states. A linear equation provided a close fit to these critical stress combinations and, thereby, provided a fiber-matrix interface failure criterion. These results suggest that prediction procedures for laminate ply cracking can be based on micromechanics stress analyses and appropriate fiber-matrix interface failure criteria. However, typical structural laminates may require elastoplastic stress analysis procedures that account for matrix yielding, especially for shear-dominated ply stress states.

Crews, J. H.↗

Deconvolution methods and systems for the mapping of acoustic sources from phased microphone arrays

A method and system for mapping acoustic sources determined from a phased microphone array. A plurality of microphones are arranged in an optimized grid pattern including a plurality of grid locations thereof. A linear configuration of N equations and N unknowns can be formed by accounting for a reciprocal influence of one or more beamforming characteristics thereof at varying grid locations among the plurality of grid locations. A full-rank equation derived from the linear configuration of N equations and N unknowns can then be iteratively determined. A full-rank can be attained by the solution requirement of the positivity constraint equivalent to the physical assumption of statically independent noise sources at each N location. An optimized noise source distribution is then generated over an identified aeroacoustic source region associated with the phased microphone array in order to compile an output presentation thereof, thereby removing the beamforming characteristics from the resulting output presentation.

Brooks, Thomas F.↗

Monte Carlo simulation of the dose response of a novel 2D silicon diode array for use in hybrid MRI–LINAC systems

Purpose: MRI-guided radiation therapy systems (MRIgRT) are being developed to improve online imaging during treatment delivery. At present, the operation of single point dosimeters and an ionization chamber array have been characterized in such systems. This work investigates a novel 2D diode array, named “magic plate,” for both single point calibration and 2D positional performance, the latter being a key element of modern radiotherapy techniques that will be delivered by these systems. Methods: GEANT4 Monte Carlo methods have been employed to study the dose response of a silicon diode array to 6 MV photon beams, in the presence of in-line and perpendicularly aligned uniform magnetic fields. The array consists of 121 silicon diodes (dimensions 1.5 × 1.5 × 0.38 mm{sup 3}) embedded in kapton substrate with 1 cm pitch, spanning a 10 × 10 cm{sup 2} area in total. A geometrically identical, water equivalent volume was simulated concurrently for comparison. The dose response of the silicon diode array was assessed for various photon beam field shapes and sizes, including an IMRT field, at 1 T. The dose response was further investigated at larger magnetic field strengths (1.5 and 3 T) for a 4 × 4 cm{sup 2} photon field size. Results: The magic plate diode array shows excellent correspondence (< ± 1%) to water dose in the in-line orientation, for all beam arrangements and magnetic field strengths investigated. The perpendicular orientation, however, exhibits a dose shift with respect to water at the high-dose-gradient beam edge of jaw-defined fields [maximum (4.3 ± 0.8)% over-response, maximum (1.8 ± 0.8)% under-response on opposing side for 1 T, uncertainty 1σ]. The trend is not evident in areas with in-field dose gradients typical of IMRT dose maps. Conclusions: A novel 121 pixel silicon diode array detector has been characterized by Monte Carlo simulation for its performance inside magnetic fields representative of current prototype and proposed MRI–linear accelerator systems. In the in-line orientation, the silicon dose is directly proportional to the water dose. In the perpendicular orientation, there is a shift in dose response relative to water in the highest dose gradient regions, at the edge of jaw-defined and single-segment MLC fields. The trend was not observed in-field for an IMRT beam. The array is expected to be a valuable tool in MRIgRT dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Mapping Spiking Neural Networks to Heterogeneous Crossbar Architectures using Integer Linear Programming

Advances in novel hardware devices and architectures allow Spiking Neural Network (SNN) evaluation using ultra-low power, mixed-signal, memristor crossbar arrays. As individual network sizes quickly scale beyond the dimensional capabilities of single crossbars, networks must be mapped onto multiple crossbars. Crossbar sizes within modern Memristor Crossbar Architectures (MCAs) are determined predominately not by device technology but by network topology; more, smaller crossbars consume less area thanks to the high structural sparsity found in larger, brain-inspired SNNs. Motivated by continuing increases in SNN sparsity due to improvements in training methods, we propose utilizing heterogeneous crossbar sizes to further reduce area consumption. This approach was previously unachievable as prior compiler studies only explored solutions targeting homogeneous MCAs. Our work improves on the state-of-the-art by providing Integer Linear Programming (ILP) formulations supporting arbitrarily heterogeneous architectures. By modeling axonal interactions between neurons, our methods produce better mappings while removing inhibitive a priori knowledge requirements. We first show a 16.7-27.6% reduction in area consumption for square-crossbar homogeneous architectures. Then, we demonstrate 66.9-72.7% further reduction when using a reasonable configuration of heterogeneous crossbar dimensions. Next, we present a new optimization formulation capable of minimizing the number of inter-crossbar routes. When applied to solutions already near-optimal in area, an 11.9-26.4% routing reduction is observed without impacting area consumption. Finally, we present a profile-guided optimization capable of minimizing the number of runtime spikes between crossbars. Compared to the best-area-then-route optimized solutions, we observe a further 0.5-14.8% inter-crossbar spike reduction while requiring 1–3 orders of magnitude less solver time.

Pohl, Devin [ORNL] (ORCID:0009000040149027)↗

SU-C-BRB-03: Novel Technique to Implement GRID Therapy in a Commercial Treatment Planning System

Purpose: Due to the difficulty of creating an accurate multi-aperture block in treatment planning systems (TPS), spatially fractionated radiation therapy (GRID Therapy) is limited to clinical setups using simple monitor unit calculations. In this work, we present a novel approach to accurately model a grid block in a TPS and evaluate its dosimetric accuracy. Methods: An acrylic GRID block was fashioned such that the hole size and spacing were the same dimensions of the brass GRID block (dotDecimal) at isocenter. Holes were non-divergent and drilled 1 cm deep. CT scans (RT Lightspeed, GE Healthcare) of the block were acquired using axial slices with a thickness of 0.625 mm. These were imported into Eclipse (version 11, Varian Medical Systems) and holes were auto-contoured into structures. The GRID block was created in Eclipse by forming apertures around the hole structures using a simple three step process. Treatment plans were created in a water-equivalent phantom using 6 and 10 MV beams, delivered with a linear accelerator (Clinac iX, Varian Medical Systems) and measured using a water tank, film and a diode array. Results: Comparisons of percent depth dose curves and profiles at depths of maximum dose, 5cm, and 10cm for field sizes ranging from 5 cm{sup 2} to 25 cm{sup 2} using water and film were within 3% of their respective positions in Eclipse. GRID plans utilizing various jaw sizes and MLC blocking measured with film and a diode array showed pass rates with an average of 97% using Gamma analysis at 3%/ 3 mm and no lower than 93%. Conclusion: We have developed a simple yet accurate method of incorporating a GRID block into a commercially available TPS and demonstrated that the TPS accurately reflects the dose delivered. This will allow for real-time planning using patient scans and encourage new methods for GRID therapy. Support provided by dotDecimal, Sanford, FL.

60 APPLIED LIFE SCIENCES↗

LOW-FREQUENCY OBSERVATIONS OF LINEARLY POLARIZED STRUCTURES IN THE INTERSTELLAR MEDIUM NEAR THE SOUTH GALACTIC POLE

We present deep polarimetric observations at 154 MHz with the Murchison Widefield Array (MWA), covering 625 deg{sup 2} centered on α = 0{sup h}and δ = −27°. The sensitivity available in our deep observations allows an in-band, frequency-dependent analysis of polarized structure for the first time at long wavelengths. Our analysis suggests that the polarized structures are dominated by intrinsic emission but may also have a foreground Faraday screen component. At these wavelengths, the compactness of the MWA baseline distribution provides excellent snapshot sensitivity to large-scale structure. The observations are sensitive to diffuse polarized emission at ∼54′ resolution with a sensitivity of 5.9 mJy beam{sup −1} and compact polarized sources at ∼2.′4 resolution with a sensitivity of 2.3 mJy beam{sup −1} for a subset (400 deg{sup 2}) of this field. The sensitivity allows the effect of ionospheric Faraday rotation to be spatially and temporally measured directly from the diffuse polarized background. Our observations reveal large-scale structures (∼1°–8° in extent) in linear polarization clearly detectable in ∼2 minute snapshots, which would remain undetectable by interferometers with minimum baseline lengths of >110 m at 154 MHz. The brightness temperature of these structures is on average 4 K in polarized intensity, peaking at 11 K. Rotation measure synthesis reveals that the structures have Faraday depths ranging from −2 to 10 rad m{sup −2} with a large fraction peaking at approximately +1 rad m{sup −2}. We estimate a distance of 51 ± 20 pc to the polarized emission based on measurements of the in-field pulsar J2330–2005. We detect four extragalactic linearly polarized point sources within the field in our compact source survey. Based on the known polarized source population at 1.4 GHz and non-detections at 154 MHz, we estimate an upper limit on the depolarization ratio of 0.08 from 1.4 GHz to 154 MHz.

79 ASTRONOMY AND ASTROPHYSICS↗