Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Data Preservation at MINERvA

Over the past ten years, MINERvA has collected an accelerator neutrino interaction dataset that is uniquely relevant to the energy range of DUNE. These are the only currently available data at intermediate and high momentum transfers for multiple nuclear targets in the same beam. MINERvA is undertaking a campaign to preserve these data and make them publicly available so that they may be analyzed beyond the end of the MINERvA collaboration. We encourage the community to consider the development of centralized resources to enable long-term access to these data and analysis tools for the entire HEP community.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multipass Beam Breakup Study at Jefferson Lab for the 12 Ge V CEBAF U pgrade

Recirculating linear accelerators (linacs) provide a compact and efficient way of accelerating particle beams to medium and high energies by reusing the same linac for multiple passes. In recirculating linacs, maximum current can be limited by multipass beam breakup (BBU), which occurs when an electron beam interacts with the higher order modes (HOMs) of accelerating cavities during multipass recirculations. The average current of the CEBAF 12 GeV Upgrade accelerator at Jefferson Lab, a 5-pass recirculating linac, may be limited by multipass BBU. This disserta- tion work was performed as part of the 12 GeV Upgrade project at Jefferson Lab to investigate limits on average beam currents from the BBU instability. Exper- imental and simulation studies were carried out, and revealed that the multipass BBU will not be a limiting factor to the average beam current in the 12 GeV Upgrade of the CEBAF accelerator. This dissertation includes the theoretical calculation for longitudinal BBU, which revealed that the maximum current limit from longitudinal BBU is much higher than the transverse one. Therefore, longitudinal BBU will not become a problem, as long as transverse BBU does not cause instability. A cumulative BBU simulation study for a new injector in the 12 GeV accelerator also was conducted. The results showed that the transient behavior of cumulative BBU in the injector is not problematic.

Shin, Ilkyoung↗

Spatial Combining of Laser-Diode Beams for Pumping an NPRO

A free-space optical beam combiner now undergoing development makes it possible to use the outputs of multiple multimode laser diodes to pump a neodymium-doped yttrium aluminum garnet (Nd:YAG) non-planar ring oscillator (NPRO) laser while ensuring that the laser operates at only a single desired frequency. Heretofore, a Nd:YAG NPRO like the present one has been pumped by a single multimode laser-diode beam delivered via an optical fiber. It would be desirable to use multiple pump laser diodes to increase reliability beyond that obtainable from a single pump laser diode. However, as explained in this article, simplistically coupling multiple multimode laser-diode beams through a fiber-optic combiner would entail a significant reduction in coupling efficiency, and lasing would occur at one or more other frequencies in addition to the single desired frequency. To minimize coupling loss, one must ensure that the NA (approximately equal to 0.3) of the combined laser-diode beams is less than the NA of the fiber. The A(Omega) of the laser-diode beam in the slow-axis plane is 1/1.3 as large as that of the fiber. This A(Omega) is small enough to enable efficient coupling of light into the optical fiber, but too large for combining of beams in the slow-axis plane. Therefore, a pair of cylindrical lenses is used to cancel the slow-axis plane magnification introduced by the on-cylindrical lenses used to effect magnification in the fast-axis plane.

Gelsinger, Paul↗

SU-E-T-133: Dosimetric Impact of Scan Orientation Relative to Target Motion During Spot Scanning Proton Therapy

Purpose: This study seeks to evaluate the dosimetric effects of intra-fraction motion during spot scanning proton beam therapy as a function of beam-scan orientation and target motion amplitude. Method: Multiple 4DCT scans were collected of a dynamic anthropomorphic phantom mimicking respiration amplitudes of 0 (static), 0.5, 1.0, and 1.5 cm. A spot-scanning treatment plan was developed on the maximum intensity projection image set, using an inverse-planning approach. Dynamic phantom motion was continuous throughout treatment plan delivery.The target nodule was designed to accommodate film and thermoluminescent dosimeters (TLD). Film and TLDs were uniquely labeled by location within the target. The phantom was localized on the treatment table using the clinically available orthogonal kV on-board imaging device. Film inserts provided data for dose uniformity; TLDs provided a 3% precision estimate of absolute dose. An inhouse script was developed to modify the delivery order of the beam spots, to orient the scanning direction parallel or perpendicular to target motion.TLD detector characterization and analysis was performed by the Imaging and Radiation Oncology Core group (IROC)-Houston. Film inserts, exhibiting a spatial resolution of 1mm, were analyzed to determine dose homogeneity within the radiation target. Results: Parallel scanning and target motions exhibited reduced target dose heterogeneity, relative to perpendicular scanning orientation. The average percent deviation in absolute dose for the motion deliveries relative to the static delivery was 4.9±1.1% for parallel scanning, and 11.7±3.5% (p<<0.05) for perpendicularly oriented scanning. Individual delivery dose deviations were not necessarily correlated to amplitude of motion for either scan orientation. Conclusions: Results demonstrate a quantifiable difference in dose heterogeneity as a function of scan orientation, more so than target amplitude. Comparison to the analyzed planar dose of a single field hint that multiple-field delivery alters intra-fraction beam-target motion synchronization and may mitigate heterogeneity, though further study is warranted.

60 APPLIED LIFE SCIENCES↗

Enabling Affordable Communications for the Burgeoning Deep Space Cubesat Fleet

The low costs of development and launch, coupled with new propulsive technologies, have made CubeSats increasingly popular for use in science investigations beyond geosynchronous orbit. As this deep space CubeSat fleet grows in size, the challenge of trying to provide affordable communications for it grows commensurately. The mass, power, and volume constraints inherent to CubeSats limit the antenna size and transmit power that they can use to close the deep space link. As a consequence, CubeSats need to rely more heavily on ground antennas that are characterized by large aperture, low noise temperatures, and relatively high-power transmitters. Such antennas are not in great abundance, nor are they inexpensive to build. For this reason, NASA’s Deep Space Network has been advocating a three-pronged approach to meeting anticipated CubeSat demand: development of simultaneous, shared-beam multi-spacecraft communications capabilities, development of large-antenna cross-support arrangements with other agencies and universities, and development of less uplink-intensive navigation techniques. This paper focuses on the pursuit of simultaneous, shared-beam multi-spacecraft communications capabilities. While the Multiple Spacecraft per Antenna (MSPA) technique has existed for over a decade, it has generally been limited to supporting downlink for just two in-beam spacecraft at a time. This limitation has largely been a function of the number and cost of available receivers. A relatively new technique that potentially overcomes this limitation is Opportunistic MSPA (OMSPA). Instead of relying on additional receivers, OMSPA makes use of a digital recorder at each ground station that is capable of capturing the intermediate frequency (IF) signals from every spacecraft in the antenna beam within the frequency bands of interest. When CubeSat projects see one or more opportunities for their CubeSat(s) to intercept the traditionally scheduled antenna beam of a “host” spacecraft, they can arrange for the CubeSat(s) to transmit open loop during those opportunities. Via a secure Internet site, the CubeSat mission operators can then retrieve the time- and frequency-relevant portions of the digital recording for subsequent demodulation and decoding, or subscribe to a service that does it for them. This “opportunistic” use of a host spacecraft’s ground antenna beam potentially enables CubeSat projects to make use of large ground antennas for downlink without having to compete with bigger, better-funded missions for antenna time in the formal scheduling process. In so doing, it also potentially enables CubeSat projects to avoid the aperture fees associated with formally scheduled downlink time - fees that factor into the “bottom-line” of competitively-bid NASA missions and that actually get charged to non-NASA missions. Taking advantage of these potential OMSPA benefits, however, will require CubeSat projects to pursue mission designs that ensure at least periodic in-beam operations relative to a “host” spacecraft. In the case of a constellation of CubeSats with inter-spacecraft distances that do not extend outside of the beam-width of the desired ground antenna at the given range, one CubeSat can serve as the “host” and have a formally scheduled downlink while the rest of the CubeSats can downlink essentially for “free” via OMSPA. Deep space CubeSats, of course, will need uplink in addition to downlink. Beyond commanding, this need is driven by the use of two-way ranging and Doppler for navigation. While OMSPA may not directly facilitate uplink, it does have the potential to free up antennas for those spacecraft that periodically require formally scheduled links for commanding and two-way radio metrics. NASA is also exploring the physical feasibility of an in-beam, simultaneous multi-spacecraft uplink technique. As with OMSPA, if successful, it will require little new equipment, further enabling affordable deep space CubeSat communications.

Abraham, Douglas S.↗

SU-E-T-462: Fixed-Jaw Optimization for Critical Structure Sparing in IMRT Treatment Planning: Beam Modeling Cautions for Non-Routine Use

Purpose: Multiple publications exist concerning fixed-jaw utilization to avoid linac carriage shifts and reduce intensity modulated radiotherapy (IMRT) treatment times. The purpose of this work is to demonstrate delivery QA discrepancies and illustrate the need for improved treatment planning system (TPS) commissioning for non-routine use. Methods: A 6cm diameter spherical target was delineated on a virtual phantom containing the Iba Matrixx linear array within the Varian Eclipse TPS. Optimization was performed for target coverage for the following 3 scenarios: a single open, zero degree field where the X and Y jaws completely cover the target; the same field using an asymmetric, fixed-jaw technique where the upper Y jaw does not cover the superior 2cm of the target; and both of the aforementioned directed at the target at 315 and 45 degree gantry angles, respectively. This final orientation was also irradiated on a linac for delivery analysis. A sarcoma patient case was also analyzed where the fixed jaw technique was utilized for kidney sparing. Results: The open beam results were as predicted but the fixed-jaw results demonstrate a pronounced fluence increase along the asymmetric, upper jaw. Analysis of the delivery of the combined beam plan Resultin 83% of pixels evaluated passing gamma criteria of 3%, 3mm DTA. Analysis for the sarcoma patient, in the plane of the shielded kidney, indicated 93% passing although the maximum dose discrepancies in this region were approximately 23%. Conclusion: Optimization within the target is routinely performed using MLC leaf-end characteristics. The fixed-jaw technique forces optimization of target coverage to utilize the penumbra profiles of the associated beamdefining jaw. If the profiles were collected using a common 0.125cc ionization chamber, the resolution may be insufficient resulting in a planvs.-delivery mismatch. It is recommended that high-resolution beam characteristics be considered when non-routine planning methods are utilized.

60 APPLIED LIFE SCIENCES↗

Energy enhancement for deuteron beam fast ignition of a precompressed inertial confinement fusion target

Fast Ignition (FI) is recognized as a potentially promising approach to achieve the high-energy-gain target performance needed for commercial inertial confinement fusion. Here we consider deuteron beam driven FI which provides not only the 'hot spot' ignition spark, but also extra ''bonus'' fusion energy through reactions in the target. In this study, we estimate the impact of the added deposition energy due to the fusion reactions occurring, based on calculations using a modified energy multiplication factor F{sub c}. The deuteron beam energy deposition range and time are also evaluated in order to estimate the desired deuteron initial energy. It is shown that an average of 30% extra energy can be gained from deuterons with 1 MeV initial energy and 12% from deuterons with 3 MeV initial energy. These results indicate that the energy benefit of this approach could be significant, but a much more comprehensive calculation is needed to realize a full 3D design for realistic experimental studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An MCNPX Monte Carlo model of a discrete spot scanning proton beam therapy nozzle

Purpose: The purposes of this study were to validate a discrete spot scanning proton beam nozzle using the Monte Carlo (MC) code MCNPX and use the MC validated model to investigate the effects of a low-dose envelope, which surrounds the beam's central axis, on measurements of integral depth dose (IDD) profiles. Methods: An accurate model of the discrete spot scanning beam nozzle from The University of Texas M. D. Anderson Cancer Center (Houston, Texas) was developed on the basis of blueprints provided by the manufacturer of the nozzle. The authors performed simulations of single proton pencil beams of various energies using the standard multiple Coulomb scattering (MCS) algorithm within the MCNPX source code and a new MCS algorithm, which was implemented in the MCNPX source code. The MC models were validated by comparing calculated in-air and in-water lateral profiles and percentage depth dose profiles for single pencil beams with their corresponding measured values. The models were then further tested by comparing the calculated and measured three-dimensional (3-D) dose distributions. Finally, an IDD profile was calculated with different scoring radii to determine the limitations on the use of commercially available plane-parallel ionization chambers to measure IDD. Results: The distance to agreement, defined as the distance between the nearest positions of two equivalent distributions with the same value of dose, between measured and simulated ranges was within 0.13 cm for both MCS algorithms. For low and intermediate pencil beam energies, the MC simulations using the standard MCS algorithm were in better agreement with measurements. Conversely, the new MCS algorithm produced better results for high-energy single pencil beams. The IDD profile calculated with cylindrical tallies with an area equivalent to the area of the largest commercially available ionization chamber showed up to 7.8% underestimation of the integral dose in certain depths of the IDD profile. Conclusions: The authors conclude that a combination of MCS algorithms is required to accurately reproduce experimental data of single pencil beams and 3-D dose distributions for the scanning beam nozzle. In addition, the MC simulations showed that because of the low-dose envelope, ionization chambers with radii as large as 4.08 cm are insufficient to accurately measure IDD profiles for a 221.8 MeV pencil beam in the scanning beam nozzle.

60 APPLIED LIFE SCIENCES↗

Sr flux stability against oxidation in oxide-molecular-beam-epitaxy environment: Flux, geometry, and pressure dependence

Maintaining stable fluxes for multiple source elements is a challenging task when the source materials have significantly different oxygen affinities in a complex-oxide molecular-beam-epitaxy (MBE) environment. Considering that Sr is one of the most easily oxidized and widely used elements in various complex oxides, we took Sr as a probe to investigate the flux-stability problem in a number of different conditions. Source oxidation was less for higher flux, extended port geometry, and unmelted source shape. The extended port geometry also eliminated the flux transient after opening a source shutter as observed in the standard port. We also found that the source oxidation occurred more easily on the crucible wall than on the surface of the source material. Atomic oxygen, in spite of its stronger oxidation effectiveness, did not make any difference in source oxidation as compared to molecular oxygen in this geometry. Our results may provide a guide for solutions to the source oxidation problem in oxide-MBE system.

36 MATERIALS SCIENCE↗

Multi-particle trapping and manipulation by a high-frequency array transducer

We report the multiple micro-particle trapping and manipulation by a single-beam acoustic tweezer using a high-frequency array transducer. A single acoustic beam generated by a 30 MHz ultrasonic linear array transducer can entrap and transport multiple micro-particles located at the main lobe and the grating lobes. The distance between trapped particles can be adjusted by changing the transmit arrangement of array-based acoustic tweezers and subsequently the location of grating lobes. The experiment results showed that the proposed method can trap and manipulate multiple particles within a range of hundreds of micrometers. Due to its simplicity and low acoustic power, which is critical to protect cells from any thermal and mechanical damages, the technique may be used for transportation of cells in cell biology, biosensors, and tissue engineering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Configurable luminaire

An array of LEDs is supported by a support mechanism that both supports conductors leading to the LEDs and sinks heat from the LEDs. The support mechanism may be a transparent heat-conducting sheet or an array of cantilevered arms at different angles that support the LEDs and sink heat. This reduces the blockage of light. The LEDs are positioned generally in the focal plane of an array of concave mirrors that collimate the light. The LEDs and array of mirrors are translatable with respect to one another to steer the aggregate light beam to customize the emission. In another embodiment, multiple LEDs are positioned over each mirror in the mirror array, and the combination of LEDs illuminated over each mirror is used to steer the aggregate light beam from the luminaire.

42 ENGINEERING↗

Production of extended plasma channels in atmospheric air by amplitude-modulated UV radiation of GARPUN-MTW Ti : sapphire-KrF laser. Part 1. Regenerative amplification of subpicosecond pulses in a wide-aperture electron beam pumped KrF amplifier

Regenerative amplification of single and multiple ultrashort subpicosecond UV pulses in a wide-aperture KrF amplifier with an unstable confocal resonator was investigated on the GARPUN-MTW hybrid laser system. Amplitude-modulated 100-ns long UV radiation pulses with an energy of several tens of joules were obtained at the output of the system. The pulses were a combination of a quasi-stationary oscillation pulse and a train of amplified ultrashort pulses (USPs) with a peak power of 0.2-0.3 TW, which exceeded the power of free-running lasing pulse by three orders of magnitude. The population inversion recovery time in the active KrF laser medium was estimated: {tau}{sub c} {<=} 2.0 ns. Trains of USPs spaced at an interval {Delta}t Almost-Equal-To {tau}{sub c} were shown to exhibit the highest amplification efficiency. The production of amplitude-modulated UV pulses opens up the way to the production and maintenance of extended plasma channels in atmospheric air. (extreme light fields and their applications)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diffractive Combiner of Single-Mode Pump Laser-Diode Beams

An optical beam combiner now under development would make it possible to use the outputs of multiple single-mode laser diodes to pump a neodymium: yttrium aluminum garnet (Nd:YAG) nonplanar ring oscillator (NPRO) laser while ensuring that the laser operates at only a single desired frequency. Heretofore, an Nd:YAG NPRO like the present one has been pumped by a single multimode laser-diode beam delivered via an optical fiber. It would be desirable to use multiple pump laser diodes to increase reliability beyond that obtainable from a single pump laser diode. However, as explained below, simplistically coupling multiple multimode laser-diode beams through a fiber-optic combiner would entail a significant reduction in coupling efficiency, and lasing would occur at one or more other frequencies in addition to the single desired frequency. Figure 1 schematically illustrates the principle of operation of a laser-diode-pumped Nd:YAG NPRO. The laser beam path is confined in a Nd:YAG crystal by means of total internal reflections on the three back facets and a partial-reflection coating on the front facet. The wavelength of the pump beam - 808 nm - is the wavelength most strongly absorbed by the Nd:YAG crystal. The crystal can lase at a wavelength of either 1,064 nm or 1,319 nm - which one depending on the optical coating on the front facet. A thermal lens effect induced by the pump beam enables stable lasing in the lowest-order transverse electromagnetic mode (the TEM00 mode). The frequency of this laser is very stable because of the mechanical stability of the laser crystal and the unidirectional nature of the lasing. The unidirectionality is a result of the combined effects of (1) a Faraday rotation induced by an externally applied magnetic field and (2) polarization associated with non-normal incidence and reflection on the front facet.

Liu, Duncan↗

SU-F-T-495: Method for Simultaneous Commissioning of Multiple Truebeam (TB) Linacs: Small Field Data and the Choice of Dosimetric Lead Gap (DLG)

Purpose: Many times a set of multiple Varian-Truebeam (TB) linacs are acquired by an institution. Since “beam matching” is an important requirement for many facilities, we developed a strategy to perform a “simultaneous” commissioning between multiple linacs.Methods and Materials: We first commissioned the required photon beam data for eclipse on the 1st TB for all the energy modalities with a beam scanning system, while integrated measurements for output factors, of all field sizes (from 1×1 to 40×40cm{sup 2}) were conducted on the 2nd TB. Care was exercised during small field dosimetry so the appropriate detectors were used with data taken between two detectors be “linked” to a larger field size (4×4cm{sup 2}) with the “daisy-chaining” technique via: OF=[M-PTW(fs)×(M-PTW(4×4))-1]×[MA12s(4×4)×(M-A12S(10×10))−1]. For all energy modalities, data that span the entire range of field size, was repeated on the next TB linac, for verification. The primarily energy-dependent dosimetric leaf gap (DLG) which was measured separately on each TB. The modeled data was validated with special measurements conducted on both linacs during commissioning. Results: Our data agreed with the “TB representative beam data” to within 0.5% for all energy modalities and field sizes ≥3×3cm2. Sample depth-doses and cross-profiles of a 3×3cm2 between the linacs agreeing to within 1% between linacs. The measured DLGs were quite different with a uniform difference of 1.3% between the two linacs. The measured DLG values are independent of the average dose rate and medium used for the measurements. Conclusion: A comprehensive method of commissioning identical Varian-TB linacs, outlining the critical issues, especially small field dosimetry and DLG. The dosimetric effect of different DLG values, when it comes to, dynamic delivery and data comparisons will be presented. The dependence of DLG value on the measurement medium (in-air vs. water) or dose rate used will also be discussed. This work was supported by CAMC Cancer Center and Alliance Oncology.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-266: Development of Evaluation System of Optimal Synchrotron Controlling Parameter for Spot Scanning Proton Therapy with Multiple Gate Irradiations in One Operation Cycle

Purpose: We have developed a gated spot scanning proton beam therapy system with real-time tumor-tracking. This system has the ability of multiple-gated irradiation in a single synchrotron operation cycle controlling the wait-time for consecutive gate signals during a flat-top phase so that the decrease in irradiation efficiency induced by irregular variation of gate signal is reduced. Our previous studies have shown that a 200 ms wait-time is appropriate to increase the average irradiation efficiency, but the optimal wait-time can vary patient by patient and day by day. In this research, we have developed an evaluation system of the optimal wait-time in each irradiation based on the log data of the real-time-image gated proton beam therapy (RGPT) system. Methods: The developed system consists of logger for operation of RGPT system and software for evaluation of optimal wait-time. The logger records timing of gate on/off, timing and the dose of delivered beam spots, beam energy and timing of X-ray irradiation. The evaluation software calculates irradiation time in the case of different wait-time by simulating the multiple-gated irradiation operation using several timing information. Actual data preserved in the log data are used for gate on and off time, spot irradiation time, and time moving to the next spot. Design values are used for the acceleration and deceleration times. We applied this system to a patient treated with the RGPT system. Results: The evaluation system found the optimal wait-time of 390 ms that reduced the irradiation time by about 10 %. The irradiation time with actual wait-time used in treatment was reproduced with accuracy of 0.2 ms. Conclusion: For spot scanning proton therapy system with multiple-gated irradiation in one synchrotron operation cycle, an evaluation system of the optimal wait-time in each irradiation based on log data has been developed. Funding Support: Japan Society for the Promotion of Science (JSPS) through the FIRST Program.

60 APPLIED LIFE SCIENCES↗

Development of activity pencil beam algorithm using measured distribution data of positron emitter nuclei generated by proton irradiation of targets containing {sup 12}C, {sup 16}O, and {sup 40}Ca nuclei in preparation of clinical application

Purpose: The purpose of this study is to develop a new calculation algorithm that is satisfactory in terms of the requirements for both accuracy and calculation time for a simulation of imaging of the proton-irradiated volume in a patient body in clinical proton therapy. Methods: The activity pencil beam algorithm (APB algorithm), which is a new technique to apply the pencil beam algorithm generally used for proton dose calculations in proton therapy to the calculation of activity distributions, was developed as a calculation algorithm of the activity distributions formed by positron emitter nuclei generated from target nuclear fragment reactions. In the APB algorithm, activity distributions are calculated using an activity pencil beam kernel. In addition, the activity pencil beam kernel is constructed using measured activity distributions in the depth direction and calculations in the lateral direction. {sup 12}C, {sup 16}O, and {sup 40}Ca nuclei were determined as the major target nuclei that constitute a human body that are of relevance for calculation of activity distributions. In this study, ''virtual positron emitter nuclei'' was defined as the integral yield of various positron emitter nuclei generated from each target nucleus by target nuclear fragment reactions with irradiated proton beam. Compounds, namely, polyethylene, water (including some gelatin) and calcium oxide, which contain plenty of the target nuclei, were irradiated using a proton beam. In addition, depth activity distributions of virtual positron emitter nuclei generated in each compound from target nuclear fragment reactions were measured using a beam ON-LINE PET system mounted a rotating gantry port (BOLPs-RGp). The measured activity distributions depend on depth or, in other words, energy. The irradiated proton beam energies were 138, 179, and 223 MeV, and measurement time was about 5 h until the measured activity reached the background level. Furthermore, the activity pencil beam data were made using the activity pencil beam kernel, which was composed of the measured depth data and the lateral data including multiple Coulomb scattering approximated by the Gaussian function, and were used for calculating activity distributions. Results: The data of measured depth activity distributions for every target nucleus by proton beam energy were obtained using BOLPs-RGp. The form of the depth activity distribution was verified, and the data were made in consideration of the time-dependent change of the form. Time dependence of an activity distribution form could be represented by two half-lives. Gaussian form of the lateral distribution of the activity pencil beam kernel was decided by the effect of multiple Coulomb scattering. Thus, the data of activity pencil beam involving time dependence could be obtained in this study. Conclusions: The simulation of imaging of the proton-irradiated volume in a patient body using target nuclear fragment reactions was feasible with the developed APB algorithm taking time dependence into account. With the use of the APB algorithm, it was suggested that a system of simulation of activity distributions that has levels of both accuracy and calculation time appropriate for clinical use can be constructed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Focusing giga-electronvolt heavy ions to micrometers at the Institute of Modern Physics

To study the radiation effect of cosmic heavy ions of low fluxes in electronics and living samples, a focusing heavy ion microbeam facility, for ions with energies of several MeV/u up to 100 MeV/u, was constructed in the Institute of Modern Physics of the Chinese Academy of Sciences. This facility has a vertical design and an experiment platform for both in-vacuum analysis and in-air irradiation. Recently, microbeam of {sup 12}C{sup 6+} with energy of 80.55 MeV/u was successfully achieved at this interdisciplinary microbeam facility with a full beam spot size of 3 {mu}m Multiplication-Sign 5 {mu}m on target in air. Different from ions with energy of several MeV/u, the very high ion energy of hundred MeV/u level induces problems in beam micro-collimation, online beam spot diagnosis, radiation protection, etc. This paper presents the microbeam setup, difficulties in microbeam formation, and the preliminary experiments performed with the facility.

36 MATERIALS SCIENCE↗

Solar radiation on Mars: Update 1991

Detailed information on solar radiation characteristics on Mars are necessary for effective design of future planned solar energy systems operating on the surface of Mars. A procedure and solar radiation related data are presented from which the daily variation of the global, direct beam and diffuse insolation on Mars are calculated. Given the optical depth of the Mars atmosphere, the global radiation is calculated from the normalized net flux function based on multiple wavelength and multiple scattering of the solar radiation. The direct beam was derived from the optical depth using Beer's law, and the diffuse component was obtained from the difference of the global and the direct beam radiation. The optical depths of the Mars atmosphere were derived from images taken of the Sun with a special diode on the cameras used on the two Viking Landers.

Appelbaum, Joseph↗