Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplicative correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

A prediction model for lift-fan simulator performance

The performance characteristics of a model VTOL lift-fan simulator installed in a two-dimensional wing are presented. The lift-fan simulator consisted of a 15-inch diameter fan driven by a turbine contained in the fan hub. The performance of the lift-fan simulator was measured in two ways: (1) the calculated momentum thrust of the fan and turbine (total thrust loading), and (2) the axial-force measured on a load cell force balance (axial-force loading). Tests were conducted over a wide range of crossflow velocities, corrected tip speeds, and wing angle of attack. A prediction modeling technique was developed to help in analyzing the performance characteristics of lift-fan simulators. A multiple linear regression analysis technique is presented which calculates prediction model equations for the dependent variables.

Yuska, J. A.↗

Atmospheric refraction errors in laser ranging systems

The effects of horizontal refractivity gradients on the accuracy of laser ranging systems were investigated by ray tracing through three dimensional refractivity profiles. The profiles were generated by performing a multiple regression on measurements from seven or eight radiosondes, using a refractivity model which provided for both linear and quadratic variations in the horizontal direction. The range correction due to horizontal gradients was found to be an approximately sinusoidal function of azimuth having a minimum near 0 deg azimuth and a maximum near 180 deg azimuth. The peak to peak variation was approximately 5 centimeters at 10 deg elevation and decreased to less than 1 millimeter at 80 deg elevation.

Gardner, C. S.↗

Photometry of Asteroid (101955) Bennu with OVIRS on OSIRIS-REx

NASA’s OSIRIS-REx spacecraft arrived at its sampling target, asteroid (101955) Bennu, in December 2018 and started a series of global observation campaigns. Here we investigate the global photometric properties of Bennu as observed by the OSIRIS-REx Visible and InfraRed Spectrometer (OVIRS) over the time period December 9, 2018, to September 26, 2019. In this study we used observations obtained over wavelengths ranging from 0.4 to 3.7 μm, with a solar phase angle range of 5.3° to 132.6°. Our aim is to characterize the global average disk-resolved photometric properties of Bennu with multiple models. The best-fit model is a McEwen model with an exponential phase function and an exponential polynomial partition function. We use this model to correct the OVIRS spectra of Bennu to a standard reference viewing and illumination geometry at visible to infrared wavelengths for the purposes of global spectral mapping. We derive a bolometric Bond albedo map in which Bennu’s surface values range from 0.021 to 0.027. We find a phase reddening effect, and our model is effective at removing this phase reddening. Our average model albedo shows a blueish spectrum with a >10% absorption feature centered at 2.74 μm. Of all comparisons with previously visited asteroids and comets, only 28P/Neujmin, 2P/Encke, and (162173) Ryugu are darker than Bennu. We find that Bennu is a few percent brighter than Ryugu in the wavelengths respectively observed by the OSIRIS-REx and Hayabusa2 missions (from 0.48 to 0.86 μm). We also compare our spectroscopic photometry of Bennu with the OSIRIS-REx imaging photometry and with ground-based predictions.

Asteroid Bennu↗

Applying the System Complexity Metric (SCM)

A fundamental cause of difficulty in larger engineering projects is their inherent complexity. An impression of complexity occurs if a system is simply difficult to understand, so that there is no obvious mental model that correctly predicts its behavior. Higher complexity is usually associated with higher cost and higher failure rate. Complexity is indicated by a system having more and diverse components, multiple interactions and feedback loops, transients and dynamic behavior, and often the emergence of unanticipated failure modes. Identifying and removing these signs of complexity should reduce complexity and improve performance. Here we limit complexity measurement to the number of components and their interactions. A System Complexity Metric (SCM) is defined as equal to the sum of the number of parts in a system, N, plus the sum of the one-way interconnections between them, I. SCM = N + I. The SCM is easily determined by direct inspection of system block diagrams. Previous work found that life support system cost was directly proportional to SCM and that failure rate increased faster than SCM squared. SCM can be used to compare systems or to guide their redesign to reduce cost and failure rate. Carbon dioxide removal systems will be analyzed using SCM, cost, and failure rate.

Harry W Jones↗

Using the System Complexity Metric (SCM) to Compare CO2 Removal Systems

A fundamental cause of difficulty in large engineering projects is their inherent complexity. An impression of complexity occurs if a system is simply difficult to understand, where there is no obvious mental model that correctly predicts its behavior. Higher system complexity is usually associated with higher cost and higher failure rate. Complexity is perceived if a system has many diverse components, multiple interactions and feedback loops, transients and dynamic behavior, and unanticipated failure modes. Identifying and removing these signs of complexity should improve performance and reduce the cost and failure rate. Complexity can be directly measured by the number of components and their interactions. The System Complexity Metric (SCM) is defined as the sum of the number of parts in a system, N, plus the number of the one-way interconnections between them, I. SCM = N + I. The SCM is easily determined by direct inspection of the system block diagram. SCM can be used to compare systems and to guide their redesign to reduce cost and failure rate. Carbon dioxide removal systems are analyzed using SCM, cost, and failure rate. As in previous work, cost is directly proportional to SCM and that failure rate increases as a power of SCM for large differences in SCM. The SCM ranking of carbon dioxide removal systems is the same as their ranking in detailed analysis and practice.

Harry W. Jones↗

Using the System Complexity Metric (SCM) to Compare CO2 Reduction Systems

A fundamental cause of difficulty in large engineering projects is their inherent complexity. An impression of complexity occurs if a system is simply difficult to understand, where there is no obvious mental model that correctly predicts its behavior. Higher system complexity is usually associated with higher cost and higher failure rate. Complexity is perceived if a system has many diverse components, multiple interactions and feedback loops, transients and dynamic behavior, and unanticipated failure modes. Identifying and removing these signs of complexity should improve performance and reduce the cost and failure rate. Complexity can be directly measured by the number of components and their interactions. The System Complexity Metric (SCM) is defined as the sum of the number of parts in a system, N, plus the number of the one-way interconnections between them, I. SCM = N + I. The SCM is easily determined by direct inspection of the system block diagram. SCM can be used to compare systems and to guide their redesign to reduce cost and failure rate. Carbon dioxide reduction systems are analyzed using SCM, cost, and failure rate. As in previous work, cost is directly proportional to SCM and that failure rate increases as a power of SCM for large differences in SCM. The SCM ranking of carbon dioxide reduction systems is the same as their ranking in detailed analysis and practice.

Harry W. Jones↗

A Bayesian Method for Identifying Contaminated Detectors in Low-Level Alpha Spectrometers

Analyses used for radiobioassay and other radiochemical tests are normally designed to meet specified quality objectives, such relative bias, precision, and minimum detectable activity (MDA). In the case of radiobioassay analyses for alpha emitting radionuclides, a major determiner of the process MDA is the instrument background. Alpha spectrometry detectors are often restricted to only a few counts over multi-day periods in order to meet required MDAs for nuclides such as plutonium-239 and americium-241. A detector background criterion is often set empirically based on experience, or frequentist or classical statistics are applied to the calculated background count necessary to meet a required MDA. An acceptance criterion for the detector background is set at the multiple of the estimated background standard deviation above the assumed mean that provides an acceptably small probability of observation if the mean and standard deviation estimate are correct. The major problem with this method is that the observed background counts used to estimate the mean, and thereby the standard deviation when a Poisson distribution is assumed, are often in the range of zero to three counts. At those expected count levels it is impossible to obtain a good estimate of the true mean from a single measurement. As an alternative, Bayesian statistical methods allow calculation of the expected detector background count distribution based on historical counts from new, uncontaminated detectors. This distribution can then be used to identify detectors showing an increased probability of contamination. The effect of varying the assumed range of background counts (i.e., the prior probability distribution) from new, uncontaminated detectors will be is discussed.

alpha↗

A Forward Branching Phase-Space Generator

We develop a forward branching phase-space generator for use in next-to-leading order parton level event generators. By performing 2 -> 3 branchings from a fixed jet phase-space point, all bremsstrahlung events contributing to the given jet configuration are generated. The resulting phase-space integration is three-dimensional irrespective of the considered jet multiplicity. In this first study, we use the forward branching phase-space generator to calculate in the leading-color approximation next-to-leading order corrections to fully differential gluonic jet configurations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Support Vector Machines for Improved Peptide Identification from Tandem Mass Spectrometry Database Search

Accurate identification of peptides is a current challenge in mass spectrometry (MS) based proteomics. The standard approach uses a search routine to compare tandem mass spectra to a database of peptides associated with the target organism. These database search routines yield multiple metrics associated with the quality of the mapping of the experimental spectrum to the theoretical spectrum of a peptide. The structure of these results make separating correct from false identifications difficult and has created a false identification problem. Statistical confidence scores are an approach to battle this false positive problem that has led to significant improvements in peptide identification. We have shown that machine learning, specifically support vector machine (SVM), is an effective approach to separating true peptide identifications from false ones. The SVM-based peptide statistical scoring method transforms a peptide into a vector representation based on database search metrics to train and validate the SVM. In practice, following the database search routine, a peptides is denoted in its vector representation and the SVM generates a single statistical score that is then used to classify presence or absence in the sample

59 BASIC BIOLOGICAL SCIENCES↗

Convolution Correction Factor Adjustments on Static PRA Models for Event Assessment

Current probabilistic risk assessment (PRA) models will contain cut sets that have time-constrained basic events such as switched components, recovery of failed components, and failures in time. For these cut sets that have multiple time-constrained events that interact (e.g., offsite power recover at the same time as multiple diesel generators fail to run), there is the possibility that the minimal cut set quantified result is too large. Since current PRA models typically assume that the accident scenario starts at “time zero,” the fails-to-run basic events use this starting time as the basis for their respective reliability models. Over time, the standard practice was to recognize this issue and accept it as part of the conservatism built into the event tree/fault tree PRA models. However, now that these same PRA models are being used in a regulatory forum, this conservatism needs to be addressed. Further, this issue exists not only for the baseline PRA results, but for deficiencies that have been observed or those that have the potential of occurrence, whether the deficiency is complete failure or just a degraded condition. We have found that this conservatism becomes very important when evaluating scenarios such as station blackout sequences and other loss of offsite power sequences. This paper will address the theory and implemented process used by the Systems Analysis Programs for Hands-on Integrated Reliability Evaluations (SAPHIRE) PRA software. Starting with SAPHIRE version 8, the process that was developed is to calculate a “convolution correction factor” based on three distinct calculations. The first calculation is the cut set based frequency calculated via the standard event tree/fault tree PRA model (assuming all run failures start at time equal to zero). The second calculation is to perform the exact time-constrained calculation by integrating the component failure models over the time period of interest (e.g., time to recover, a mission time). For example, this exact calculation for the case of the diesel generators is to convolve their failure models with the offsite power recovery model to obtain the exact frequency. The third calculation is to produce the convolution correction factor by dividing the exact frequency calculation by the standard cut set frequency. This convolution correction factor is then applied to the PRA cut sets in order to remove the time-constrained conservatism. The process used to obtain the convolution correction factor for the baseline PRA is important; however, in this paper we also describe what happens when there is degradation of a component or a potential deficiency. These issues become very important in order to ensure that the convolution correction factor is re-calculated correctly. If the correction factor does not get re-calculated and the same baseline convolution correction factor is used, the final analysis result could be over conservative or under conservative. This paper will discuss how these issues are addressed and provide examples on how SAPHIRE automatically makes the necessary adjustments. MathCad verification results can be computed using the provided equations and input data.

99 GENERAL AND MISCELLANEOUS↗

Automated registration of multispectral MR vessel wall images of the carotid artery

Purpose: Atherosclerosis is the primary cause of heart disease and stroke. The detailed assessment of atherosclerosis of the carotid artery requires high resolution imaging of the vessel wall using multiple MR sequences with different contrast weightings. These images allow manual or automated classification of plaque components inside the vessel wall. Automated classification requires all sequences to be in alignment, which is hampered by patient motion. In clinical practice, correction of this motion is performed manually. Previous studies applied automated image registration to correct for motion using only nondeformable transformation models and did not perform a detailed quantitative validation. The purpose of this study is to develop an automated accurate 3D registration method, and to extensively validate this method on a large set of patient data. In addition, the authors quantified patient motion during scanning to investigate the need for correction. Methods: MR imaging studies (1.5T, dedicated carotid surface coil, Philips) from 55 TIA/stroke patients with ipsilateral <70% carotid artery stenosis were randomly selected from a larger cohort. Five MR pulse sequences were acquired around the carotid bifurcation, each containing nine transverse slices: T1-weighted turbo field echo, time of flight, T2-weighted turbo spin-echo, and pre- and postcontrast T1-weighted turbo spin-echo images (T1W TSE). The images were manually segmented by delineating the lumen contour in each vessel wall sequence and were manually aligned by applying throughplane and inplane translations to the images. To find the optimal automatic image registration method, different masks, choice of the fixed image, different types of the mutual information image similarity metric, and transformation models including 3D deformable transformation models, were evaluated. Evaluation of the automatic registration results was performed by comparing the lumen segmentations of the fixed image and moving image after registration. Results: The average required manual translation per image slice was 1.33 mm. Translations were larger as the patient was longer inside the scanner. Manual alignment took 187.5 s per patient resulting in a mean surface distance of 0.271 ± 0.127 mm. After minimal user interaction to generate the mask in the fixed image, the remaining sequences are automatically registered with a computation time of 52.0 s per patient. The optimal registration strategy used a circular mask with a diameter of 10 mm, a 3D B-spline transformation model with a control point spacing of 15 mm, mutual information as image similarity metric, and the precontrast T1W TSE as fixed image. A mean surface distance of 0.288 ± 0.128 mm was obtained with these settings, which is very close to the accuracy of the manual alignment procedure. The exact registration parameters and software were made publicly available. Conclusions: An automated registration method was developed and optimized, only needing two mouse clicks to mark the start and end point of the artery. Validation on a large group of patients showed that automated image registration has similar accuracy as the manual alignment procedure, substantially reducing the amount of user interactions needed, and is multiple times faster. In conclusion, the authors believe that the proposed automated method can replace the current manual procedure, thereby reducing the time to analyze the images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

QED nuclear medium effects at EIC energies

Here, we present the first calculation of quantum electrodynamics (QED) nuclear medium effects under the experimental conditions of future Electron-Ion Collider (EIC) experiments. Our work offers numerical estimates, particularly in the context of inclusive deep inelastic scattering on a $^{208}_{82}$Pb nucleus. While prior studies have predominantly focused on elastic scattering, our investigation extends to the more complex scenarios of inelastic processes within a nuclear medium. Our findings suggest that the cross section corrections due to QED nuclear medium effects could be substantial, reaching or exceeding the level of experimental precision. This work further compares the effects of single rescattering events with those of multiple rescatterings, as particles travel the nuclear volume. We estimate the dominant source of the uncertainties associated with our formalism by varying the scale of the atomic physics where the screening of the electric field of the nucleus happens. This calculation not only contributes to the understanding of QED nuclear medium effects, but also offers a path to a more precise extraction of the process-independent nonperturbative structure of nuclei.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Can a radiological event impact a criticality safety program: Lessons learned at WIPP - 14350

Any accident at a nuclear facility impacts all departments involved in the operation of the facility. The radiological release that occurred on February 14, 2014 has halted all waste disposal operations at the Waste Isolation Pilot Plant (WIPP) and has resulted in detailed reviews of all safety management programs. This paper describes the initial reactions to the event, criticality issues with recovery operations, corrective actions for the criticality safety program from independent reviews, and the importance of configuration management to criticality safety. The nature, location, and timing of the event resulted in significant delays in determining the cause of the event. During this time multiple theories on the initiator of the event were postulated including and inadvertent criticality event. However, the timing of the event, average fissile gram equivalent (FGE) loading of waste containers compared to analyzed FGE loads, and isotopic analysis of fixed air samples taken during the event proved it was not an inadvertent criticality event. Recovery activities such as replacing contaminated high efficiency particulate (HEPA), filters and disposing of site generated waste have also been reviewed to prevent criticality safety issues. Post event corrective actions in all departments have impacted how future operations at WIPP will be conducted, including corrective actions for the criticality safety program. The event has also proven the importance of configuration management and the effect a change can have on a process. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-P-07: Retrospective Analysis of Incident Reports at a Radiology Department: Feedback From Incident Reporting System

Purpose: To provide an overview of reported incidents that occurred in a radiology department and to describe the most common causal source of incidents. Methods: Incident reports from the radiology department at the University of the Ryukyus Hospital between 2008 and 2013 were collected and analyzed retrospectively. The incident report form contains the following items, causal factors of the incident and desirable corrective actions to prevent recurrence of similar incidents. These items allow the institution to investigate/analyze root causes of the incidents and suggest measures to be taken to prevent further, similar incidents. The ‘causal factors of the incident’ item comprises multiple selections from among 24 selections and includes some synonymous selections. In this study, this item was re-categorized into four causal source types: (i) carelessness, (ii) lack of skill or knowledge, (iii) deficiencies in communication, and (iv) external factors. Results: There were a total of 7490 incident reports over the study period and 276 (3.7%) were identified as originating from the radiology department. The most frequent causal source type was carelessness (62%). The other three types showed similar frequencies (10–14%). The staff members involved in incidents indicate three predominant desirable corrective actions to prevent or decrease the recurrence of similar incidents. These are ‘improvement in communication’ (24%), ‘staff training/education’ (19%), and ‘daily medical procedures’ (22%), and the most frequent was ‘improvement in communication’. Even though the most frequent causal factor was related to carelessness, the most desirable corrective action indicated by the staff members was related to communication. Conclusion: Our finding suggests that the most immediate causes are strongly related to carelessness. However, the most likely underlying causes of incidents would be related to deficiencies in effective communication. At our department, therefore, the primary action to prevent/reduce similar incidents should be ‘communication improvement’.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improvement of structural models using covariance analysis and nonlinear generalized least squares

The next generation of large, flexible space structures will be too light to support their own weight, requiring a system of structural supports for ground testing. The authors have proposed multiple boundary-condition testing (MBCT), using more than one support condition to reduce uncertainties associated with the supports. MBCT would revise the mass and stiffness matrix, analytically qualifying the structure for operation in space. The same procedure is applicable to other common test conditions, such as empty/loaded tanks and subsystem/system level tests. This paper examines three techniques for constructing the covariance matrix required by nonlinear generalized least squares (NGLS) to update structural models based on modal test data. The methods range from a complicated approach used to generate the simulation data (i.e., the correct answer) to a diagonal matrix based on only two constants. The results show that NGLS is very insensitive to assumptions about the covariance matrix, suggesting that a workable NGLS procedure is possible. The examples also indicate that the multiple boundary condition procedure more accurately reduces errors than individual boundary condition tests alone.

Glaser, R. J.↗

Simulation of Rate-Related (Dead-Time) Losses In Passive Neutron Multiplicity Counting Systems

Passive Neutron Multiplicity Counting (PNMC) based on Multiplicity Shift Register (MSR) electronics (a form of time correlation analysis) is a widely used non-destructive assay technique for quantifying spontaneously fissile materials such as Pu. At high event rates, dead-time losses perturb the count rates with the Singles, Doubles and Triples being increasingly affected. Without correction these perturbations are a major source of inaccuracy in the measured count rates and assay values derived from them. This paper presents the simulation of dead-time losses and investigates the effect of applying different dead-time models on the observed MSR data. Monte Carlo methods have been used to simulate neutron pulse trains for a variety of source intensities and with ideal detection geometry, providing an event by event record of the time distribution of neutron captures within the detection system. The action of the MSR electronics was modelled in software to analyse these pulse trains. Stored pulse trains were perturbed in software to apply the effects of dead-time according to the chosen physical process; for example, the ideal paralysable (extending) and non-paralysable models with an arbitrary dead-time parameter. Results of the simulations demonstrate the change in the observed MSR data when the system dead-time parameter is varied. In addition, the paralysable and non-paralysable models of deadtime are compared. These results form part of a larger study to evaluate existing dead-time corrections and to extend their application to correlated sources. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation and Calibration of Nuclear Thermal Hydraulics Multiscale Multiphysics Models - Subcooled Flow Boiling Study

In addition to validation data plan, development of advanced techniques for calibration and validation of complex multiscale, multiphysics nuclear reactor simulation codes are a main objective of the CASL VUQ plan. Advanced modeling of LWR systems normally involves a range of physico-chemical models describing multiple interacting phenomena, such as thermal hydraulics, reactor physics, coolant chemistry, etc., which occur over a wide range of spatial and temporal scales. To a large extent, the accuracy of (and uncertainty in) overall model predictions is determined by the correctness of various sub-models, which are not conservation-laws based, but empirically derived from measurement data. Such sub-models normally require extensive calibration before the models can be applied to analysis of real reactor problems. This work demonstrates a case study of calibration of a common model of subcooled flow boiling, which is an important multiscale, multiphysics phenomenon in LWR thermal hydraulics. The calibration process is based on a new strategy of model-data integration, in which, all sub-models are simultaneously analyzed and calibrated using multiple sets of data of different types. Specifically, both data on large-scale distributions of void fraction and fluid temperature and data on small-scale physics of wall evaporation were simultaneously used in this work’s calibration. In a departure from traditional (or common-sense) practice of tuning/calibrating complex models, a modern calibration technique based on statistical modeling and Bayesian inference was employed, which allowed simultaneous calibration of multiple sub-models (and related parameters) using different datasets. Quality of data (relevancy, scalability, and uncertainty) could be taken into consideration in the calibration process. This work presents a step forward in the development and realization of the “CIPS Validation Data Plan” at the Consortium for Advanced Simulation of LWRs to enable quantitative assessment of the CASL modeling of Crud-Induced Power Shift (CIPS) phenomenon, in particular, and the CASL advanced predictive capabilities, in general. This report is prepared for the Department of Energy’s Consortium for Advanced Simulation of LWRs program’s VUQ Focus Area.

97 MATHEMATICS AND COMPUTING↗

Corrective Action Study for the Former CCC/USDA Facility in Powhattan, Kansas (TR-18-01)

Low concentrations of carbon tetrachloride and chloroform have been identified in soil and groundwater in Powhattan, Kansas, at and near areas where grain handling operations have occurred for more than a century. Since about 1890, grain has been stored at several locations on the Chicago Rock Island and Pacific Railroad right-of-way by multiple parties, including the Brown County Cooperative Association (now Ag Partners Cooperative, Inc.), and — from 1949 to approximately1966 — the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA).

54 ENVIRONMENTAL SCIENCES↗