Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Local Measurement in Annular Flows Using a Two-Sensor Droplet-Capable Conductivity Probe

Two-sensor electrical conductivity probes have been widely used for detailed local measurement in two-phase flow systems. However application of conductivity probes in liquid-dispersed flows has been limited. In the churn-turbulent to annular transition and annular flow regimes, the liquid phase exists as a continuous phase in the film and ligaments, and as a dispersed phase in the droplets. The conventional design of a conductivity probe is not valid because it cannot distinguish the dispersed liquid phase from the gas phase. In this paper, the Two-Sensor Droplet-Capable Conductivity Probe (DCCP-2) is designed in order to extend measurement capability to liquid-dispersed flows. The liquid phase is classified into droplets and ligaments. The interface velocity, volume fraction, interfacial area concentration, as well as the chord length of liquid droplets and ligaments, can be calculated from the raw signal. The radial distribution of these parameters and the probability distribution of chord length and velocity are obtained for downwards flow in a vertical pipe. The results show that although the average volume fraction of droplets is only on the order of 1%, droplets contribute to around 20%-30% to the entrained liquid phase in the gas core, the remainder as ligaments. The interfacial area concentration from droplets and ligaments are in the order of 300 m{sup -1}. (authors)

42 ENGINEERING↗

Digital Twin Technology for Safety, Security, and Training in Spent Nuclear Fuel Handling

The increasing complexity of spent nuclear fuel handling requires significant resources to ensure safety, security, and personnel training. As nuclear facilities have continued to advance in scale and technology, the integration of digital tools has become indispensable. Among these tools, digital twins, which are virtual models of physical systems, are emerging as invaluable tools for enhancing safety protocols, security measures, and training in the nuclear sector. These models were conceptualized in the Industry 4.0 revolution. Digital twins can process data from physical systems in real time (by using sensors), include multiple code packages to enable simulations of different physics applications, and even implement artificial intelligence or machine learning techniques for advanced data processing. Despite the advantages that digital twins provide, challenges still exist regarding their widespread implementation. For instance, data used by a digital twin must be accurate to ensure that the digital twin is accurately tuned. Furthermore, if insecure digital twins are targeted by hackers, then they can pose serious risks to the security and safety of nuclear facilities.

Digital twins↗

Wireless energizing system for an automated implantable sensor

The wireless drive of an automated implantable electronic sensor has been explored for health monitoring applications. The proposed system comprises of an automated biomedical sensing system which is energized through resonant inductive coupling. The implantable sensor unit is able to monitor the body temperature parameter and sends back the corresponding telemetry data wirelessly to the data recoding unit. It has been observed that the wireless power delivery system is capable of energizing the automated biomedical implantable electronic sensor placed over a distance of 3 cm from the power transmitter with an energy transfer efficiency of 26% at the operating resonant frequency of 562 kHz. This proposed method ensures real-time monitoring of different human body temperatures around the clock. The monitored temperature data have been compared with a calibrated temperature measurement system to ascertain the accuracy of the proposed system. The investigated technique can also be useful for monitoring other body parameters such as blood pressure, bladder pressure, and physiological signals of the patient in vivo using various implantable sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enrichment Assay Methods Development for the Integrated Cylinder Verification System

International Atomic Energy Agency (IAEA) inspectors currently perform periodic inspections at uranium enrichment plants to verify UF 6 cylinder enrichment declarations. Measurements are typically performed with handheld high-resolution sensors on a sampling of cylinders taken to be representative of the facility's entire product-cylinder inventory. Pacific Northwest National Laboratory (PNNL) is developing a concept to automate the verification of enrichment plant cylinders to enable 100 percent product-cylinder verification and potentially, mass-balance calculations on the facility as a whole (by also measuring feed and tails cylinders). The Integrated Cylinder Verification System (ICVS) could be located at key measurement points to positively identify each cylinder, measure its mass and enrichment, store the collected data in a secure database, and maintain continuity of knowledge on measured cylinders until IAEA inspector arrival. The three main objectives of this FY09 project are summarized here and described in more detail in the report: (1) Develop a preliminary design for a prototype NDA system, (2) Refine PNNL's MCNP models of the NDA system, and (3) Procure and test key pulse-processing components. Progress against these tasks to date, and next steps, are discussed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Self characterization of a coded aperture array for neutron source imaging

The neutron imaging system at the National Ignition Facility (NIF) is an important diagnostic tool for measuring the two-dimensional size and shape of the neutrons produced in the burning deuterium-tritium plasma during the stagnation stage of inertial confinement fusion implosions. Since the neutron source is small (∼100 μm) and neutrons are deeply penetrating (>3 cm) in all materials, the apertures used to achieve the desired 10-μm resolution are 20-cm long, triangular tapers machined in gold foils. These gold foils are stacked to form an array of 20 apertures for pinhole imaging and three apertures for penumbral imaging. These apertures must be precisely aligned to accurately place the field of view of each aperture at the design location, or the location of the field of view for each aperture must be measured. In this paper we present a new technique that has been developed for the measurement and characterization of the precise location of each aperture in the array. We present the detailed algorithms used for this characterization and the results of reconstructed sources from inertial confinement fusion implosion experiments at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity analysis of single-layer graphene resonators using atomic finite element method

Atomic finite element simulation is applied to study the natural frequency and sensitivity of a single-layer graphene-based resonator with CCCC, SSSS, CFCF, SFSF, and CFCF boundary conditions using the commercial code ANSYS. The fundamental frequencies of the graphene sheet are compared with the results of the previous finite element study. In addition, the sensitivity of the resonator is compared with the early work based on nonlocal elasticity theory. The results of the comparison are very good in all considered cases. The sensitivities of the resonator with different boundary conditions are obtained, and the order based on the boundary condition is CCCC > SSSS > CFCF > SFSF > CFFF. The highest sensitivity is obtained when the attached mass is located at the center of the resonator. This is useful for the design of a highly sensitive graphene-based mass sensor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NASA Tech Briefs, January 2008

Topics covered include: Induction Charge Detector with Multiple Sensing Stages; Generic Helicopter-Based Testbed for Surface Terrain Imaging Sensors; Robot Electronics Architecture; Optimized Geometry for Superconducting Sensing Coils; Sensing a Changing Chemical Mixture Using an Electronic Nose; Inertial Orientation Trackers with Drift Compensation; Microstrip Yagi Antenna with Dual Aperture-Coupled Feed; Patterned Ferroelectric Films for Tunable Microwave Devices; Micron-Accurate Laser Fresnel-Diffraction Ranging System; Efficient G(sup 4)FET-Based Logic Circuits; Web-Enabled Optoelectronic Particle-Fallout Monitor; SiO2/TiO2 Composite for Removing Hg from Combustion Exhaust; Lightweight Tanks for Storing Liquefied Natural Gas; Hybrid Wound Filaments for Greater Resistance to Impacts; Making High-Tensile-Strength Amalgam Components; Bonding by Hydroxide-Catalyzed Hydration and Dehydration; Balanced Flow Meters without Moving Parts; Deflection-Compensating Beam for Use inside a Cylinder; Four-Point-Latching Microactuator; Curved Piezoelectric Actuators for Stretching Optical Fibers; Tunable Optical Assembly with Vibration Dampening; Passive Porous Treatment for Reducing Flap Side-Edge Noise; Cylindrical Piezoelectric Fiber Composite Actuators; Patterning of Indium Tin Oxide Films; Gimballed Shoulders for Friction Stir Welding; Improved Thermal Modulator for Gas Chromatography; Nuclear-Spin Gyroscope Based on an Atomic Co-Magnetometer; Utilizing Ion-Mobility Data to Estimate Molecular Masses; Optical Displacement Sensor for Sub-Hertz Applications; Polarization/Spatial Combining of Laser-Diode Pump Beams; Spatial Combining of Laser-Diode Beams for Pumping an NPRO; Algorithm Optimally Orders Forward-Chaining Inference Rules; Project Integration Architecture; High Power Amplifier and Power Supply; Estimating Mixing Heights Using Microwave Temperature Profiler; and Multiple-Cone Sunshade for a Spaceborne Telescope.

Source record↗

Magnetic field sensors using 13-spin cat states

Measurement devices could benefit from entangled correlations to yield a measurement sensitivity approaching the physical Heisenberg limit. Building upon previous magnetometric work using pseudoentangled spin states in solution-state NMR, we present two conceptual advancements to better prepare and interpret the pseudoentanglement resource. We apply these to a 13-spin cat state to measure the local magnetic field with a 12.2 sensitivity increase over an equivalent number of isolated spins.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Validation of Calorimetric Electron Capture Spectral Theory with 193 Pt

Using microcalorimeters, a high statistics, high-resolution calorimetric spectrum of electron capture in 163 Ho can be used to determine the neutrino mass. The spectral shape can be calculated from first principles with various assumptions and approximations. To determine the validity of these choices, the theoretical calculations must be compared to data from multiple isotopes. In this work, new calorimetric data for a 193 Pt-in-Pt absorber measured with a transition edge sensor are presented and compared to theoretical calculations and values from the literature.

74 ATOMIC AND MOLECULAR PHYSICS↗

MULTI-MODAL global surveillance methodology for predictive and on-demand characterization of localized processes using cube satellite platforms and deep learning techniques

This paper presents the work completed towards the development of a multi-modal global surveillance methodology using cube satellite (CubeSat) platforms and novel data analysis techniques. A CubeSat system equipped with adequate sensors and data analytics capabilities can autonomously characterize various phenomena of interest on the Earth’s surface. CubeSats are advantageous over conventional satellites in certain remote monitoring applications because of their reduced construction costs (due to the availability of commercially-off-the-shelf components) and are easier to launch. The CubeSat surveillance system developed in this paper focused on phenomena of interest surrounding the nuclear fuel cycle in support of nuclear non-proliferation and emergency response. To observe the phenomena, a constellation of 3U and 6U CubeSats deployed from the ISS with adequate components was chosen. Four different sensor configurations were identified for remote sensing: panchromatic/multispectral in the visible and near-infrared spectrum, multispectral in infrared spectrum, hyperspectral in infrared spectrum, and multispectral in ultraviolet spectrum. While a panchromatic/multispectral sensor configuration has CubeSat flight heritage at the required spatial resolutions, the other three sensor types need future 3 development to meet signature and system requirements. Once each sensor onboard the CubeSat system collects data on a target of interest, the onboard computers would then apply the deep learning-based characterization methodology developed in this paper to identify phenomena. Four surrogate datasets containing representative simplified “images” were created for each sensor type to train the characterization methodology. A convolutional neural network was applied to each dataset and produced recall rates for the phenomena between 89.7% - 99.3% and precision rates between 92.3% - 99.9%. Each phenomenon’s presence probability from each network is then combined into a final characterization solution for a target area. This paper covers multiple interdisciplinary areas to develop the foundation for a CubeSat surveillance system focused on phenomena surrounding the nuclear fuel cycle.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Monitoring Waste Tanks Using Guided Wave Technology - 18576

There are many challenges associated with the inspections of double-shell storage tanks containing radioactive waste, including limited space for accessibility and maneuverability, environments with high radiation, temperature and toxicity, and unknown physical conditions. Contents of the tank and limited space may prevent access of scanning devices that employ conventional NDE techniques such as ultrasonics, eddy current, or magnetic based methods. Resolving these challenges will become more urgent as the nuclear industry is forced to address the complications of the aging nuclear infrastructure - specifically at tank storage locations on laboratory sites across the DOE complex. A powerful, new approach to inspecting and monitoring the structural integrity of large structures, such as double-shelled tanks, is being developed using ultrasonic guided waves. Acoustic waves that propagate in a plate or other structure where the wavelength is larger than the thickness of the structure are known as ultrasonic guided waves. Ultrasonic guided waves can potentially propagate distances of tens to hundreds of feet in plate-like structures, such as those that comprise the walls and bottom of a storage tank. Guided waves enable the examination of relatively large inspection volumes from the outside surface of the structure. In double-shell tanks, the technology offers promise for examining the floor of the structure or the walls by placing guided wave sensors at accessible locations in the annulus. This guided wave technology has the capability to detect and localize areas of damage or degradation. While guided wave has recently been used in the nuclear and oil and gas industries for inspecting one-dimensional piping systems, current research is developing methods to apply this technology to the two-dimensional surfaces of double-shell storage tanks. Permanently installed sensors are being developed which would remotely collect data that would be analyzed to monitor the structural condition of the tank. Initial tests have been conducted on single plate structures to study guided wave interaction with various shapes and sizes of pertinent simulated damage mechanisms, and the experimental results were compared with hybrid finite-element numerical models. Dispersion curves were calculated to study guided wave modes and their properties in carbon steel plates and to evaluate behaviors at joints between plates. The next steps in the research process include applying the transmitters and sensors to full scale mockups, developing more mature data interpretation, and then demonstrations at an actual site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Touch sensors based on planar liquid crystal-gated-organic field-effect transistors

We report a tactile touch sensor based on a planar liquid crystal-gated-organic field-effect transistor (LC-g-OFET) structure. The LC-g-OFET touch sensors were fabricated by forming the 10 μm thick LC layer (4-cyano-4{sup ′}-pentylbiphenyl - 5CB) on top of the 50 nm thick channel layer (poly(3-hexylthiophene) - P3HT) that is coated on the in-plane aligned drain/source/gate electrodes (indium-tin oxide - ITO). As an external physical stimulation to examine the tactile touch performance, a weak nitrogen flow (83.3 μl/s) was employed to stimulate the LC layer of the touch device. The LC-g-OFET device exhibited p-type transistor characteristics with a hole mobility of 1.5 cm{sup 2}/Vs, but no sensing current by the nitrogen flow touch was measured at sufficiently high drain (V{sub D}) and gate (V{sub G}) voltages. However, a clear sensing current signal was detected at lower voltages, which was quite sensitive to the combination of V{sub D} and V{sub G}. The best voltage combination was V{sub D} = −0.2 V and V{sub G} = −1 V for the highest ratio of signal currents to base currents (i.e., signal-to-noise ratio). The change in the LC alignment upon the nitrogen flow touch was assigned as the mechanism for the present LC-g-OFET touch sensors.

36 MATERIALS SCIENCE↗

Space charge dosimeters for extremely low power measurements of radiation in shipping containers

Methods and apparatus are described for space charge dosimeters for extremely low power measurements of radiation in shipping containers. A method includes insitu polling a suite of passive integrating ionizing radiation sensors including reading-out dosimetric data from a first passive integrating ionizing radiation sensor and a second passive integrating ionizing radiation sensor, where the first passive integrating ionizing radiation sensor and the second passive integrating ionizing radiation sensor remain situated where the dosimetric data was integrated while reading-out. Another method includes arranging a plurality of ionizing radiation sensors in a spatially dispersed array; determining a relative position of each of the plurality of ionizing radiation sensors to define a volume of interest; collecting ionizing radiation data from at least a subset of the plurality of ionizing radiation sensors; and triggering an alarm condition when a dose level of an ionizing radiation source is calculated to exceed a threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robot for Investigations and Assessments of Nuclear Areas

RIANA is a remote controlled Robot dedicated for Investigations and Assessments of Nuclear Areas. The development of RIANA is motivated by the need to have at disposal a proven robot, tested in hot cells; a robot capable of remotely investigate and characterise the inside of nuclear facilities in order to collect efficiently all the required data in the shortest possible time. It is based on a wireless medium sized remote carrier that may carry a wide variety of interchangeable modules, sensors and tools. It is easily customised to match specific requirements and quickly configured depending on the mission and the operator's preferences. RIANA integrates localisation and navigation systems. The robot will be able to generate / update a 2D map of its surrounding and exploring areas. The position of the robot is given accurately on the map. Furthermore, the robot will be able to autonomously calculate, define and follow a trajectory between 2 points taking into account its environment and obstacles. The robot is configurable to manage obstacles and restrict access to forbidden areas. RIANA allows an advanced control of modules, sensors and tools; all collected data (radiological and measured data) are displayed in real time in different format (chart, on the generated map...) and stored in a single place so that may be exported in a convenient format for data processing. This modular design gives RIANA the flexibility to perform multiple investigation missions where humans cannot work such as: visual inspections, dynamic localization and 2D mapping, characterizations and nuclear measurements of floor and walls, non destructive testing, samples collection: solid and liquid. The benefits of using RIANA are: - reducing the personnel exposures by limiting the manual intervention time, - minimizing the time and reducing the cost of investigation operations, - providing critical inputs to set up and optimize cleanup and dismantling operations. (authors)

42 ENGINEERING↗

Development of a Plasma Panel Muon Detector

A radiation detector technology based on Plasma Display Panels (PDP), the underlying engine of panel plasma television displays is being investigated. Emerging from this well established television technology is the Plasma Panel Sensor (PPS), a novel variant of the micropattern radiation detector. The PPS is fundamentally a fast, high resolution detector comprised of an array of plasma discharge cells operating in a hermetically sealed gas mixture. We report on the PPS development effort, including proof-of-principle results of laboratory signal observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear reactor radiation and temperature effects on piezoelectric surface acoustic wave devices

Surface acoustic wave (SAW) resonators were characterized in-situ in a nuclear reactor environment at high temperature. Devices based on lithium niobate (LiNbO 3 ), aluminum nitride (sc-AlN), and thin-film aluminum nitride on sapphire substrate (AlN/sapphire) were tested up to 400 °C temperature and 1.9 × 10 12 n/cm 2 s neutron flux. Shifts in device resonant frequency were detected in response to temperature and neutron flux. Devices undergo a frequency change when exposed to neutron flux. At 300 °C, AlN/sapphire produced the strongest neutron flux response about 1.02 ppm at 1.27 × 10 12 n/cm 2 s neutron flux (5.7 × 10 4 rad-Si/hr neutron dose rate), compared to 0.30 ppm for LiNbO 3 and 0.17 ppm for sc-AlN. While the transient kinetics in response to step change in neutron flux support the defect-accumulation mechanism, the concurrent measurement of device temperature using resistive temperature sensor suggests additional heating caused by absorption of gamma rays can also play a role. These results make SAW devices attractive candidates for sensor applications in extreme environments.

Aluminum nitride↗

Validating Safecast data by comparisons to a U. S. Department of Energy Fukushima Prefecture aerial survey

Safecast is a volunteered geographic information (VGI) project where the lay public collects radiation measurements via hand-held sensors that are uploaded to a central server and then made freely available. However, Safecast data fidelity is uncertain given that the these sensors are hand assembled with various levels of technical proficiency, and that the sensors may not be properly deployed. We validated Safecast data gathered in the Fukushima Prefecture shortly after the Daiichi nuclear power plant catastrophe by comparing it with authoritative data collected by the Department of Energy (DOE) and the National Nuclear Security Administration (NNSA) during the same period. We found that the two data sets were highly correlated, though the DOE/NNSA observations were generally higher than the Safecast measurements. We concluded that this high correlation alone makes Safecast a viable data source for detecting and monitoring fallout during radiological emergencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗