Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Motion as a perturbation: Measurement-guided dose estimates to moving patient voxels during modulated arc deliveries

Purpose: To present a framework for measurement-guided VMAT dose reconstruction to moving patient voxels from a known motion kernel and the static phantom data, and to validate this perturbation-based approach with the proof-of-principle experiments. Methods: As described previously, the VMAT 3D dose to a static patient can be estimated by applying a phantom measurement-guided perturbation to the treatment planning system (TPS)-calculated dose grid. The fraction dose to any voxel in the presence of motion, assuming the motion kernel is known, can be derived in a similar fashion by applying a measurement-guided motion perturbation. The dose to the diodes in a helical phantom is recorded at 50 ms intervals and is transformed into a series of time-resolved high-density volumetric dose grids. A moving voxel is propagated through this 4D dose space and the fraction dose to that voxel in the phantom is accumulated. The ratio of this motion-perturbed, reconstructed dose to the TPS dose in the phantom serves as a perturbation factor, applied to the TPS fraction dose to the similarly situated voxel in the patient. This approach was validated by the ion chamber and film measurements on four phantoms of different shape and structure: homogeneous and inhomogeneous cylinders, a homogeneous cube, and an anthropomorphic thoracic phantom. A 2D motion stage was used to simulate the motion. The stage position was synchronized with the beam start time with the respiratory gating simulator. The motion patterns were designed such that the motion speed was in the upper range of the expected tumor motion (1-1.4 cm/s) and the range exceeded the normally observed limits (up to 5.7 cm). The conformal arc plans for X or Y motion (in the IEC 61217 coordinate system) consisted of manually created narrow (3 cm) rectangular strips moving in-phase (tracking) or phase-shifted by 90 Degree-Sign (crossing) with respect to the phantom motion. The XY motion was tested with the computer-derived VMAT MLC sequences. For all phantoms and plans, time-resolved (10 Hz) ion chamber dose was collected. In addition, coronal (XY) films were exposed in the cube phantom to a VMAT beam with two different starting phases, and compared to the reconstructed motion-perturbed dose planes. Results: For the X or Y motions with the moving strip and geometrical phantoms, the maximum difference between perturbation-reconstructed and ion chamber doses did not exceed 1.9%, and the average for any motion pattern/starting phase did not exceed 1.3%. For the VMAT plans on the cubic and thoracic phantoms, one point exhibited a 3.5% error, while the remaining five were all within 1.1%. Across all the measurements (N = 22), the average disagreement was 0.5 {+-} 1.3% (1 SD). The films exhibited {gamma}(3%/3 mm) passing rates {>=}90%. Conclusions: The dose to an arbitrary moving voxel in a patient can be estimated with acceptable accuracy for a VMAT delivery, by performing a single QA measurement with a cylindrical phantom and applying two consecutive perturbations to the TPS-calculated patient dose. The first one accounts for the differences between the planned and delivered static doses, while the second one corrects for the motion.

60 APPLIED LIFE SCIENCES↗

Patterning approach for detecting defect in device manufacturing

Compact handheld devices which were a dream in the past are now a reality; this has been enabled by miniaturization of circuit architectures including power devices. Scaling down of the design feature sizes does come with a price with an increase in systematic defects during chip manufacturing. There are generally two methods of inline defect detection adopted to monitor the semiconductor device fabrication—optical inspection and electron beam inspection. The optical inspection uses ultra-violet and deep ultra-violet (UV/DUV) light to find patterning defects on the wafer. While the electron-beam inspection uses electron charge and discharge measurement to find electrical connection defects, both are a costly procedure in terms of resources and time. The physical limit of feature resolution of the optical source is now making the defect inspection job difficult in miniaturized application specific integrated circuit (ASIC). This study is designed to test the patterning optimization approach on both inspection platforms. Using hotspot analysis weak locations are identified in the full chip design, and then they are verified in the inline wafer inspection. The criterion for hot-spot determination is also discussed in this paper.

36 MATERIALS SCIENCE↗

Graphene milling dynamics during helium ion beam irradiation

We explore the potential of the Helium Ion Microscope (HIM) as a tool for direct-write patterning of graphene and describe the underlying processes of graphene milling with image data processing. Controlled helium ion irradiation of suspended graphene conducted while monitoring the mill in-situ revealed the localized formation of nanopores, their growth, and coalescence. We also explore the effects of defects on the milling dynamics, and show that pre-exposed membranes rupture by cracking and rapid crack propagation at the edges of the growing defects. The mechanism for the rupturing process is described by local defect formation by excessive irradiation of helium ions, dictated by the scanning direction of the beam. As a result, these findings enrich fundamental understanding of the graphene milling process with a helium ion beam that, is necessary for high-resolution and high throughput patterning of graphene with nanoscale precision.

36 MATERIALS SCIENCE↗

Microstructural strain mapping during in-situ cyclic testing of ductile iron

Highlights: • A method for quantitative study of crack formation and propagation during cyclic loading was developed. • Focused Ion Beam Milling was shown to be an effective method to generate a high quality speckle pattern for Digital Image Correlation measurements • The method enabled a high-resolution measurement of localized strain in the microstructure of ductile iron • The peak strain and the strain distribution ahead of the growing crack under load were quantified - Abstract: This paper focuses on local strain distribution in the microstructure of high silicon ductile iron during cyclic loading. In-situ cyclic test was performed on compact-tension (CT) samples inside the scanning electron microscope (SEM) to record the whole deformation and obtain micrographs for microstructural strain measurement by means of digital image correlation (DIC) technique. Focused ion beam (FIB) milling was used to generate speckle patterns necessary for DIC measurement. The equivalent Von Mises strain distribution was measured in the microstructure at the maximum applied load. The results revealed a heterogeneous strain distribution at the microstructural level with higher strain gradients close to the notch of the CT sample and accumulated strain bands between graphite particles. Local strain ahead of the early initiated micro-cracks was quantitatively measured, showing high strain localization, which decreased by moving away from the micro-crack tip. It could be observed that the peak of strain in the field of view was not necessarily located ahead of the micro-cracks tip which could be because of the (i) strain relaxation due to the presence of other micro-cracks and/or (ii) presence of subsurface microstructural features such as graphite particles that influenced the strain concentration on the surface.

36 MATERIALS SCIENCE↗

A thin-walled composite beam model for light-weighted structures interacting with fluids

A thin-walled beam model is proposed for structures of variable cross-section, which can be either open or closed and includes multicellular cross-sections with either isotropic or orthotropic materials. The proposed model does not require any priori definition of cross-sectional warping which instead results from the solution of the problem. To achieve that a special deformation pattern is superimposed on the bending deformation described by Euler–Bernoulli beam theory. All sectional properties are automatically incorporated in the analysis as a result of the usual variational formulation of the system of equations. The proposed model is specifically designed to simulate the dynamics of wind/hydrokinetic turbine blade with low computational cost, especially in fluid–structure interaction (FSI) simulation. A number of test cases have been carried out to validate the proposed structural model which show good agreement between the results obtained her e and the solutions available in literature. Finally, FSI simulation of a hydrokinetic blade under field condition is carried out to illustrate the capability of the current thin-walled beam model in practice.

42 ENGINEERING↗

Speckle contrast of interfering fluorescence X-rays

With the development of X-ray free-electron lasers (XFELs), producing pulses of femtosecond durations comparable with the coherence times of X-ray fluorescence, it has become possible to observe intensity–intensity correlations due to the interference of emission from independent atoms. This has been used to compare durations of X-ray pulses and to measure the size of a focused X-ray beam, for example. Here it is shown that it is also possible to observe the interference of fluorescence photons through the measurement of the speckle contrast of angle-resolved fluorescence patterns. Speckle contrast is often used as a measure of the degree of coherence of the incident beam or the fluctuations of the illuminated sample as determined from X-ray diffraction patterns formed by elastic scattering, rather than from fluorescence patterns as addressed here. Commonly used approaches to estimate speckle contrast were found to suffer when applied to XFEL-generated fluorescence patterns due to low photon counts and a significant variation of the excitation pulse energy from shot to shot. A new method to reliably estimate speckle contrast under such conditions, using a weighting scheme, is introduced. The method is demonstrated by comparing the speckle contrast of fluorescence observed with pulses of 3 fs to 15 fs duration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Controlling magnetic anisotropy in La{sub 0.7}Sr{sub 0.3}MnO{sub 3} nanostructures

We have developed a chlorine based dry etching process for nanopatterning the ferromagnetic oxide La{sub 0.7}Sr{sub 0.3}MnO{sub 3} (LSMO). Large arrays of millions of identical structures have been fabricated from thin LSMO films by electron-beam lithography and reactive ion etching. SQUID magnetometry demonstrates that patterned nanostructures with lateral dimensions down to 100 nm retain their full magnetization and the Curie temperature of the bulk layer. In addition, their shape anisotropy is sufficient to overcome the crystalline anisotropy of the bulk. High resolution scanning transmission electron microscopy shows that crystallinity is preserved even at the edges of the nanostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Selective formation of porous silicon

A pattern of porous silicon is produced in the surface of a silicon substrate by forming a pattern of crystal defects in said surface, preferably by applying an ion milling beam through openings in a photoresist layer to the surface, and then exposing said surface to a stain etchant, such as HF:HNO3:H20. The defected crystal will preferentially etch to form a pattern of porous silicon. When the amorphous content of the porous silicon exceeds 70 percent, the porous silicon pattern emits visible light at room temperature.

Fathauer, Jones↗

Selective formation of porous silicon

A pattern of porous silicon is produced in the surface of a silicon substrate by forming a pattern of crystal defects in said surface, preferably by applying an ion milling beam through openings in a photoresist layer to the surface, and then exposing said surface to a stain etchant, such as HF:HNO3:H2O. The defected crystal will preferentially etch to form a pattern of porous silicon. When the amorphous content of the porous silicon exceeds 70 percent, the porous silicon pattern emits visible light at room temperature.

Fathauer, Robert W.↗

Least-work analysis of the problem of shear lag in box beams

The distribution of stress in the cover sheets of thin-wall box beams is analyzed, with regard to the effect of shear deformation in the cover sheets, by the method of least work. Explicit results are obtained for a number of representative cases that show the influence of the following factors on the stress patterns. (1) Variation of stress in spanwise direction as given by elementary beam theory. (2) Value of a parameter called shear-lag aspect ratio which designates the product of span-width ratio of the beam and of the square root of the ratio of effective shear modulus and tensing modulus of the cover sheets. (3) Value of ratio of cover-sheet stiffness to side-web stiffness. (4) Variation of beam height in span direction. (5) Variation of beam width in span direction. (6) Variation of cover-sheet thickness in span direction. General conclusions are drawn from the results obtained. Among them the most important one appears to be the fact that the shear-lag effect depends primarily on the following tow quantities: (1) the value of the shear-lag aspect ratio. (2) the shape of the curve representing the product of the stress of elementary beam theory and of the cover-sheet thickness.

STRESS CALCULATIONS, LEAST-WORK↗

Feasibility and robustness of dose painting by numbers in proton therapy with contour-driven plan optimization

Purpose: To prove the ability of protons to reproduce a dose gradient that matches a dose painting by numbers (DPBN) prescription in the presence of setup and range errors, by using contours and structure-based optimization in a commercial treatment planning system. Methods: For two patients with head and neck cancer, voxel-by-voxel prescription to the target volume (GTV{sub PET}) was calculated from {sup 18}FDG-PET images and approximated with several discrete prescription subcontours. Treatments were planned with proton pencil beam scanning. In order to determine the optimal plan parameters to approach the DPBN prescription, the effects of the scanning pattern, number of fields, number of subcontours, and use of range shifter were separately tested on each patient. Different constant scanning grids (i.e., spot spacing = Δx = Δy = 3.5, 4, and 5 mm) and uniform energy layer separation [4 and 5 mm WED (water equivalent distance)] were analyzed versus a dynamic and automatic selection of the spots grid. The number of subcontours was increased from 3 to 11 while the number of beams was set to 3, 5, or 7. Conventional PTV-based and robust clinical target volumes (CTV)-based optimization strategies were considered and their robustness against range and setup errors assessed. Because of the nonuniform prescription, ensuring robustness for coverage of GTV{sub PET} inevitably leads to overdosing, which was compared for both optimization schemes. Results: The optimal number of subcontours ranged from 5 to 7 for both patients. All considered scanning grids achieved accurate dose painting (1% average difference between the prescribed and planned doses). PTV-based plans led to nonrobust target coverage while robust-optimized plans improved it considerably (differences between worst-case CTV dose and the clinical constraint was up to 3 Gy for PTV-based plans and did not exceed 1 Gy for robust CTV-based plans). Also, only 15% of the points in the GTV{sub PET} (worst case) were above 5% of DPBN prescription for robust-optimized plans, while they were more than 50% for PTV plans. Low dose to organs at risk (OARs) could be achieved for both PTV and robust-optimized plans. Conclusions: DPBN in proton therapy is feasible with the use of a sufficient number subcontours, automatically generated scanning patterns, and no more than three beams are needed. Robust optimization ensured the required target coverage and minimal overdosing, while PTV-approach led to nonrobust plans with excessive overdose. Low dose to OARs can be achieved even in the presence of a high-dose escalation as in DPBN.

60 APPLIED LIFE SCIENCES↗

Wurtzite ZnO (001) films grown on cubic MgO (001) with bulk-like opto-electronic properties

We report the growth of ZnO (001) wurtzite thin films with bulk-like opto-electronic properties on MgO (001) cubic substrates using plasma-assisted molecular beam epitaxy. In situ reflection high-energy electron diffraction patterns and ex situ high resolution transmission electron microscopy images indicate that the structure transition from the cubic MgO substrates to the hexagonal films involves 6 ZnO variants that have the same structure but different orientations. This work demonstrates the possibility of integrating wurtzite ZnO films and functional cubic substrates while maintaining their bulk-like properties.

36 MATERIALS SCIENCE↗

Sizing Up the Situation

Hailstorm damage to the Space Shuttle's External Tank inspired a NASA innovation with extensive photography applications. In order to measure the defects caused by the storm, Kennedy Space Center used telephoto lenses to zoom in on the tank and view the damage clearly. However, since there was no reference object in the image, the engineers could not determine the scale of the damage. In photographic situations similar to this, an object, such as a ruler, is placed within the field of view. This allows a person to look at a photograph and have a visual indication of the scale of the objects in it. In the External Tank situation, however, this procedure was not possible. As a solution, Kennedy developed the Scaling and Measurement Device for Photographic Images, which provides a non-intrusive means of adding a scale to a photograph. In addition to meeting Kennedy's needs, scaling images is extremely important in crime and accident scene investigations, oil and chemical tank monitoring, and aerial photography. The innovation consists of a tool that attaches directly to a camera or charge coupled device using a standard screw. Two lasers fitted to the device provide parallel beams that are set 1 inch apart. These lasers enable the device to project a pattern into the field of view. When a photograph is taken, the image of the laser pattern appears, along with the image of the object under investigation, allowing the viewer quantifiable information as to the size of the object. The laser beams are accurate to approximately 200 feet. Windows-based software was developed to work with the scaling device tool. The software provides further techniques to measure objects in photographs and digital images. By using the software, any object in the image can be measured diagonally, vertically, and horizontally. The device and its software enable the user to determine two-dimensional measurements within a photograph.

Source record↗

Structure of the runaway electron loss during induced disruptions in TEXTOR

The loss of runaway electrons during an induced disruption is recorded by a synchrotron imaging technique using a fast infrared CCD camera. The loss is predominantly diffuse. During the “spiky-loss phase”, when the runaway beam moves close to the wall, a narrow channel between the runaway column and a scintillator probe is formed and lasts until the runaway beam is terminated. In some cases, the processed images show a stripe pattern at the plasma edge. A comparison between the MHD dominated disruptions and the MHD-free disruption is performed. A new mechanism of plasma disruptions with the runaway electron generation and a novel model which reproduces many characteristic features of the plasma beam evolution during a disruption is briefly described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synchronized voltage contrast display analysis system

An apparatus and method for comparing internal voltage potentials of first and second operating electronic components such as large scale integrated circuits (LSI's) in which voltage differentials are visually identified via an appropriate display means are described. More particularly, in a first embodiment of the invention a first and second scanning electron microscope (SEM) are configured to scan a first and second operating electronic component respectively. The scan pattern of the second SEM is synchronized to that of the first SEM so that both simultaneously scan corresponding portions of the two operating electronic components. Video signals from each SEM corresponding to secondary electron signals generated as a result of a primary electron beam intersecting each operating electronic component in accordance with a predetermined scan pattern are provided to a video mixer and color encoder.

Johnston, M. F.↗

Selective CW Laser Synthesis of MoS2 and Mixture of MoS2 and MoO2 from (NH4)2MoS4 Film

Very recently, the synthesis of 2D MoS2 and WS2 through pulsed laser-directed thermolysis can achieve wafer-scale and large-area structures, in ambient conditions. In this paper, we report the synthesis of MoS2 and MoS2 oxides from (NH4)2MoS4 film using a visible continuous-wave (CW) laser at 532 nm, instead of the infrared pulsed laser for the laser-directed thermolysis. The (NH4)2MoS4 film is prepared by dissolving its crystal powder in DI water, sonicating the solution, and dip-coating onto a glass slide. We observed a laser intensity threshold for the laser synthesis of MoS2, however, it occurred in a narrow laser intensity range. Above that range, a mixture of MoS2 and MoO2 is formed, which can be used for a memristor device, as demonstrated by other research groups. We did not observe a mixture of MoS2 and MoO3 in the laser thermolysis of (NH4)2MoS4. The laser synthesis of MoS2 in a line pattern is also achieved through laser scanning. Due to of the ease of CW beam steering and the fine control of laser intensities, this study can lead toward the CW laser-directed thermolysis of (NH4)2MoS4 film for the fast, non-vacuum, patternable, and wafer-scale synthesis of 2D MoS2.

(NH4)2MoS4↗

Diverse corrugation pattern in radially shrinking carbon nanotubes

Stable cross sections of multiwalled carbon nanotubes subjected to electron-beam irradiation are investigated in the realm of the continuum mechanics approximation. The self-healing nature of sp{sup 2} graphitic sheets implies that selective irradiation of the outermost walls causes their radial shrinkage with the remaining inner walls undamaged. The shrinking walls exert high pressure on the interior part of nanotubes, yielding a wide variety of radial-corrugation patterns (i.e., circumferentially wrinkling structures) in the cross section. All corrugation patterns can be classified into two deformation phases for which the corrugation amplitudes of the innermost wall differ significantly.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗