Search NASA⌕ Search

SEARCH · Search NASA

Results for “random response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Overview of Integrated Random Vibration Testing of the NASA Orion Crew Survival Suit

The launch ascent and abort random vibration environments from NASA’s Orion spacecraft drove the need to test the NASA Orion Crew Survival Suit as an integrated system with exposure to the design levels. In order to properly characterize component responses, a series of integrated tests were designed to incorporate the interaction between a crew member, suit, seat, and the attenuation system. The first Development Test (2017) included human subjects, and was performed with early development seat and suit components, and low level inputs. It provided a baseline for frequency response and behavior of the integrated system. The next two tests, Development Test (2019) and Qualification Test (2020), used manikin surrogates to represent the crew member and increasing levels of component hardware fidelity in order to test to higher input levels. Testing was performed at NASA Johnson Space Center (JSC) and Kennedy Space Center (KSC) Vibration Labs and provided the input levels required to represent the ascent and abort vehicle profiles as well as recorded component response behavior from accelerometer instrumentation and high speed cameras. Inspection of the suit and related components showed that for all seat orientations, and input environments, no damage occurred. Additional pre and post-test checks confirmed the functionality of all suited hardware. Response data of the suited components generally showed heavy attenuation across most of the tested frequency range. Transmissibility plots showed some amplification of components at lower frequency ranges. Overall this series of integrated tests showed that 1) the use of surrogate manikins in the tests were adequate for representing crew in a vibration environment, 2) full vibration levels for ascent and abort were heavily attenuated in the suit components and were non-damaging, and 3) the suit and related components are qualified for the Orion random vibration environments.

Jeffrey Suhey↗

Observation of spatter-induced stochastic lack-of-fusion in laser powder bed fusion using in situ process monitoring

Material produced via additive manufacturing (AM) continues to exhibit variable mechanical properties despite apparent optimization of processing parameters, inhibiting qualification efforts and limiting use in critical applications. Stochastic lack-of-fusion flaws may help explain this variability, but the origin of these seemingly random defects has to this point remained unclear. In this work, we show that spatter particles, material ejected from the laser melt pool, are directly responsible for generating stochastic lack-of-fusion in laser-based powder bed fusion components through the application of spatial statistics. Herein a statistically significant, causal relationship between spatter particles and stochastic lack-of-fusion is established, and the spatial and morphological relationships between spatter and internal flaws are investigated. The occurrence of spatter-induced lack-of-fusion in relation to the inert gas flow and laser trajectory direction is also investigated, and recommendations for mitigating the occurrence of spatter are evaluated.

36 MATERIALS SCIENCE↗

H{beta} LINE WIDTHS AS AN ORIENTATION INDICATOR FOR LOW-IONIZATION BROAD ABSORPTION LINE QUASARS

There is evidence from radio-loud quasars to suggest that the distribution of the H{beta} broad emission line (BEL) gas is arranged in a predominantly planar orientation, and this result may well also apply to radio-quiet quasars. This would imply that the observed FWHM of the H{beta} BELs is dependent on the orientation of the line of sight to the gas. If this view is correct then we propose that the FWHM can be used as a surrogate, in large samples, to determine the line of sight to the H{beta} BELs in broad absorption line quasars (BALQSOs). The existence of broad UV absorption lines (BALs) means that the line of sight to BALQSOs must also pass through the BAL out-flowing gas. It is determined that there is a statistically significant excess of narrow-line profiles in the SDSS DR7 archival spectra of low-ionization broad absorption line quasars (LoBALQSOs), indicating that BAL gas flowing close to the equatorial plane does not commonly occur in these sources. We also find that the data is not well represented by random lines of sight to the BAL gas. Our best fit indicates two classes of LoBALQSOs, the majority ({approx}2/3) are polar outflows that are responsible for the enhanced frequency of narrow-line profiles, and the remainder are equatorial outflows. We further motivated the line of sight explanation of the narrow-line excess in LoBALQSOs by considering the notion that the skewed distribution of line profiles is driven by an elevated Eddington ratio in BALQSOs. We constructed a variety of control samples comprised of non-LoBALQSOs matched to a de-reddened LoBALQSO sample in redshift, luminosity, black hole mass, and Eddington ratio. It is demonstrated that the excess of narrow profiles persists within the LoBALQSO sample relative to each of the control samples with no reduction of the statistical significance. Thus, we eliminate the possibility that the excess narrow lines seen in the LoBALQSOs arise from an enhanced Eddington ratio.

79 ASTRONOMY AND ASTROPHYSICS↗

Classification of light sources and their interaction with active and passive environments

Emission from a molecular light source depends on its optical and chemical environment. This dependence is different for various sources. We present a general classification in terms of constant-amplitude and constant-power sources. Using this classification, we have described the response to both changes in the local density of states and stimulated emission. The unforeseen consequences of this classification are illustrated for photonic studies by random laser experiments and are in good agreement with our correspondingly developed theory. Our results require a revision of studies on sources in complex media.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic domain dynamics in an insulating quantum ferromagnet

The statistics and form of avalanches in a driven system reveal the nature of the underlying energy landscape and dynamics. In conventional metallic ferromagnets, eddy-current back action can dominate the dynamics. Here, we study Barkhausen noise in Li(Ho,Y)F 4 , an insulating Ising ferromagnet that cannot sustain eddy currents. In addition, for large avalanches at temperatures approaching the Curie point, we find a symmetric response free of drag effects. In the low-temperature limit, drag effects contribute to the dynamics, which we link to enhanced pinning from local random fields that are enabled by the microscopic dipole-coupled Hamiltonian (the Ising model in transverse field).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Itinerant approach to magnetic neutron scattering of FeSe: Effect of orbital selectivity

Current STM experiments and theoretical considerations have highlighted the role of interaction-driven orbital selectivity in FeSe, and its role in generating the extremely anisotropic superconducting gap structure in this material. We study here the magnetic excitation spectrum resulting from the coherent quasiparticles within the same renormalized random phase approximation approach used to explain the STM experiments, and show that it agrees well with the low-energy momentum and energy dependent response measured by inelastic neutron scattering experiments. We find a correlation-induced suppression of (π,π) scattering due to a small quasiparticle weight of states of d xy character. We compare predictions for twinned and untwinned crystals, and predict in particular a strongly (π,0)-dominated response at low energies in untwinned systems, in contrast to previous itinerant theories.

36 MATERIALS SCIENCE↗

Canonical-basis time-dependent Hartree-Fock-Bogoliubov theory and linear-response calculations

We present simple equations for a canonical-basis (Cb) formulation of the time-dependent Hartree-Fock-Bogoliubov (TDHFB) theory. The equations are obtained from the TDHFB theory with an approximation that the pair potential is assumed to be diagonal in the Cb. The Cb formulation significantly reduces the computational cost. We apply the method to linear-response calculations for even-even light nuclei and demonstrate its capability and accuracy by comparing our results with recent calculations of the quasiparticle random-phase approximation with Skyrme functionals. We show systematic studies of E1 strength distributions for Ne and Mg isotopes. The evolution of the low-lying pygmy strength seems to be determined by the interplay of several factors, which include the neutron excess, the separation energy, the neutron-shell effects, the deformation, and the pairing.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Distributed Automatic Generation Control Considering DPV Using T&D Dynamic Co-Simulation

The increasing adoption of distributed energy resources (DERs) over the last decade warrants a reconsideration of control of generation resources. This paper proposes a distributed Automatic Generation Control (AGC) using transmission-and-distribution (T&D) dynamic co-simulation framework for the efficient DPV frequency regulation services. The co-simulation framework allows AGC units to exchange the information for distributed AGC, based on their adopted communication network topology. As a result, a cost-effective automatic generation control is achieved with DPV and conventional generators. The proposed distributed AGC is based on the gossip algorithm in which the neighboring AGC units share the relevant local information with each other and updates their share of AGC regulation signal. Distributed photovoltaics (DPV) unit contribute to AGC response based on their headroom capacity via DER aggregators. The algorithm is tested on IEEE-14 bus transmission system under conditions of generation failure and random load variation to observe effective frequency regulations service offered by DPVs and other AGC units. The study shows that DPV can effectively participate in AGC with the proposed distributed control framework.

automatic generation control↗

Computer-aided detection of breast masses: Four-view strategy for screening mammography

Purpose: To improve the performance of a computer-aided detection (CAD) system for mass detection by using four-view information in screening mammography. Methods: The authors developed a four-view CAD system that emulates radiologists' reading by using the craniocaudal and mediolateral oblique views of the ipsilateral breast to reduce false positives (FPs) and the corresponding views of the contralateral breast to detect asymmetry. The CAD system consists of four major components: (1) Initial detection of breast masses on individual views, (2) information fusion of the ipsilateral views of the breast (referred to as two-view analysis), (3) information fusion of the corresponding views of the contralateral breast (referred to as bilateral analysis), and (4) fusion of the four-view information with a decision tree. The authors collected two data sets for training and testing of the CAD system: A mass set containing 389 patients with 389 biopsy-proven masses and a normal set containing 200 normal subjects. All cases had four-view mammograms. The true locations of the masses on the mammograms were identified by an experienced MQSA radiologist. The authors randomly divided the mass set into two independent sets for cross validation training and testing. The overall test performance was assessed by averaging the free response receiver operating characteristic (FROC) curves of the two test subsets. The FP rates during the FROC analysis were estimated by using the normal set only. The jackknife free-response ROC (JAFROC) method was used to estimate the statistical significance of the difference between the test FROC curves obtained with the single-view and the four-view CAD systems. Results: Using the single-view CAD system, the breast-based test sensitivities were 58% and 77% at the FP rates of 0.5 and 1.0 per image, respectively. With the four-view CAD system, the breast-based test sensitivities were improved to 76% and 87% at the corresponding FP rates, respectively. The improvement was found to be statistically significant (p<0.0001) by JAFROC analysis. Conclusions: The four-view information fusion approach that emulates radiologists' reading strategy significantly improves the performance of breast mass detection of the CAD system in comparison with the single-view approach.

60 APPLIED LIFE SCIENCES↗

Reducing radiation dose to the female breast during CT coronary angiography: A simulation study comparing breast shielding, angular tube current modulation, reduced kV, and partial angle protocols using an unknown-location signal-detectability metric

Purpose: The authors compared the performance of five protocols intended to reduce dose to the breast during computed tomography (CT) coronary angiography scans using a model observer unknown-location signal-detectability metric.Methods: The authors simulated CT images of an anthropomorphic female thorax phantom for a 120 kV reference protocol and five “dose reduction” protocols intended to reduce dose to the breast: 120 kV partial angle (posteriorly centered), 120 kV tube-current modulated (TCM), 120 kV with shielded breasts, 80 kV, and 80 kV partial angle (posteriorly centered). Two image quality tasks were investigated: the detection and localization of 4-mm, 3.25 mg/ml and 1-mm, 6.0 mg/ml iodine contrast signals randomly located in the heart region. For each protocol, the authors plotted the signal detectability, as quantified by the area under the exponentially transformed free response characteristic curve estimator (A-caret{sub FE}), as well as noise and contrast-to-noise ratio (CNR) versus breast and lung dose. In addition, the authors quantified each protocol's dose performance as the percent difference in dose relative to the reference protocol achieved while maintaining equivalent A-caret{sub FE}.Results: For the 4-mm signal-size task, the 80 kV full scan and 80 kV partial angle protocols decreased dose to the breast (80.5% and 85.3%, respectively) and lung (80.5% and 76.7%, respectively) with A-caret{sub FE} = 0.96, but also resulted in an approximate three-fold increase in image noise. The 120 kV partial protocol reduced dose to the breast (17.6%) at the expense of increased lung dose (25.3%). The TCM algorithm decreased dose to the breast (6.0%) and lung (10.4%). Breast shielding increased breast dose (67.8%) and lung dose (103.4%). The 80 kV and 80 kV partial protocols demonstrated greater dose reductions for the 4-mm task than for the 1-mm task, and the shielded protocol showed a larger increase in dose for the 4-mm task than for the 1-mm task. In general, the CNR curves indicate a similar relative ranking of protocol performance as the corresponding A-caret{sub FE} curves, however, the CNR metric overestimated the performance of the shielded protocol for both tasks, leading to corresponding underestimates in the relative dose increases compared to those obtained when using the A-caret{sub FE} metric.Conclusions: The 80 kV and 80 kV partial angle protocols demonstrated the greatest reduction to breast and lung dose, however, the subsequent increase in image noise may be deemed clinically unacceptable. Tube output for these protocols can be adjusted to achieve a more desirable noise level with lesser breast dose savings. Breast shielding increased breast and lung dose when maintaining equivalent A-caret{sub FE}. The results demonstrated that comparisons of dose performance depend on both the image quality metric and the specific task, and that CNR may not be a reliable metric of signal detectability.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nanomagnet-Based Physically Unclonable Functions

Physically unclonable functions are physical entities or devices that generate unique, unpredictable responses to inputs. They are important in many security applications, including encryption, authentication, anti-counterfeiting, etc. Physical unclonable functions are based on the unavoidable randomness in the manufacturing processes and are impossible to duplicate, even by the original manufacturer. In this project, we studied the feasibility of using hardened SmCo nanomagnets as the physical implementation of physically unclonable functions. Hardened SmCo nano-magnets were fabricated through a lift-off process as well as an etch-back process. The magnetization of these nano-magnets was mapped out as a function of shapes, dimensions, and processing conditions, using magnetic force microscopy. A systematic, uncontrolled bias in the polarity was identified. Attempts to mitigate this bias were made but were unsuccessful. Nevertheless, we found in the process that blanket SmCo films themselves may serve as the desired physically unclonable functions.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Flaw Tolerance of Octet Truss Lattices with Random Flaws

We investigate the behavior of octet truss lattices in which some proportion of the bars are randomly removed from a perfect lattice. Using a lattice specimen of 9 × 9 × 9 octet truss unit cells as the nominal design, we simulate the response of prefect and flawed lattices with a finite element method implementation of rod theory. For each of two simple load cases, we perform a Monte Carlo analysis where we consider many instantiations of flawed lattices where between 1% and 20% of the bars are missing, and compare the axial loads in the remaining bars to those in the perfect lattice. We also compare the overall stiffness of the flawed lattices to the perfect lattice. Our results show progressive deterioration of lattice strength and stiffness with increasing proportion of missing bars, as expected, with the location and magnitude of the highest-loaded (most failure-prone) bars depending more on the load case and bar orientation than on the location and connectivity of missing bars. As such, the results reported herein may not be directly transferable to different lattice geometries.

36 MATERIALS SCIENCE↗

A new test statistic for climate models that includes field and spatial dependencies using Gaussian Markov random fields

Abstract. A new test statistic for climate model evaluation has been developed that potentially mitigates some of the limitations that exist for observing and representing field and space dependencies of climate phenomena. Traditionally such dependencies have been ignored when climate models have been evaluated against observational data, which makes it difficult to assess whether any given model is simulating observed climate for the right reasons. The new statistic uses Gaussian Markov random fields for estimating field and space dependencies within a first-order grid point neighborhood structure. We illustrate the ability of Gaussian Markov random fields to represent empirical estimates of field and space covariances using "witch hat" graphs. We further use the new statistic to evaluate the tropical response of a climate model (CAM3.1) to changes in two parameters important to its representation of cloud and precipitation physics. Overall, the inclusion of dependency information did not alter significantly the recognition of those regions of parameter space that best approximated observations. However, there were some qualitative differences in the shape of the response surface that suggest how such a measure could affect estimates of model uncertainty.

54 ENVIRONMENTAL SCIENCES↗

Analytical prediction of the interior noise for cylindrical models of aircraft fuselages for prescribed exterior noise fields. Phase 1: Development and validation of preliminary analytical models

The basic theoretical work required to understand sound transmission into an enclosed space (that is, one closed by the transmitting structure) is developed for random pressure fields and for harmonic (tonal) excitation. The analysis is used to predict the noise reducton of unpressurized unstiffened cylinder, and also the interior response of the cylinder given a tonal (plane wave) excitation. Predictions and measurements are compared and the transmission is analyzed. In addition, results for tonal (harmonic) mechanical excitation are considered.

Pope, L. D.↗

Vibration Modal Characterization of a Stirling Convertor via Base-Shake Excitation

The U.S. Department of Energy (DOE), Lockheed Martin (LM), Stirling Technology Company (STC), and NASA John H. Glenn Research Center (GRC) are currently developing a high-efficiency Stirling convertor for use in a Stirling Radioisotope Generator (SRG). NASA and DOE have identified the SRG for potential use as an advanced power system for future NASA Space Science missions, providing spacecraft onboard electric power for deep space missions and power for unmanned Mars rovers. Low-level, baseshake sine vibration tests were conducted on the Stirling Technology Demonstration Convertor (TDC), at NASA GRC's Structural Dynamics Laboratory, in February 2001, as part of the development of this Stirling technology. The purpose of these tests was to provide a better understanding of the TDC's internal dynamic response to external vibratory base excitations. The knowledge obtained can therein be used to help explain the success that the TDC enjoyed in its previous random vibration qualification tests (December 1999). This explanation focuses on the TDC s internal dynamic characteristics in the 50 to 250 Hz frequency range, which corresponds to the maximum input levels of its qualification random vibration test specification. The internal dynamic structural characteristics of the TDC have now been measured in two separate tests under different motoring and dynamic loading conditions: (1) with the convertor being electrically motored, under a vibratory base-shake excitation load, and (2) with the convertor turned off, and its alternator internals undergoing dynamic excitation via hammer impact loading. This paper addresses the test setup, procedure and results of the base-shake vibration testing conducted on the motored TDC, and will compare these results with those results obtained from the dynamic impact tests (May 2001) on the nonmotored TDC.

Suarez, Vicente J.↗

A Nonlinear Viscoelastic Model for Ceramics at High Temperatures

High-temperature creep behavior of ceramics is characterized by nonlinear time-dependent responses, asymmetric behavior in tension and compression, and nucleation and coalescence of voids leading to creep rupture. Moreover, creep rupture experiments show considerable scatter or randomness in fatigue lives of nominally equal specimens. To capture the nonlinear, asymmetric time-dependent behavior, the standard linear viscoelastic solid model is modified. Nonlinearity and asymmetry are introduced in the volumetric components by using a nonlinear function similar to a hyperbolic sine function but modified to model asymmetry. The nonlinear viscoelastic model is implemented in an ABAQUS user material subroutine. To model the random formation and coalescence of voids, each element is assigned a failure strain sampled from a lognormal distribution. An element is deleted when its volumetric strain exceeds its failure strain. Element deletion has been implemented within ABAQUS. Temporal increases in strains produce a sequential loss of elements (a model for void nucleation and growth), which in turn leads to failure. Nonlinear viscoelastic model parameters are determined from uniaxial tensile and compressive creep experiments on silicon nitride. The model is then used to predict the deformation of four-point bending and ball-on-ring specimens. Simulation is used to predict statistical moments of creep rupture lives. Numerical simulation results compare well with results of experiments of four-point bending specimens. The analytical model is intended to be used to predict the creep rupture lives of ceramic parts in arbitrary stress conditions.

Powers, Lynn M.↗

Modeling Techniques for Evaluation the Effectiveness of Particle Damping in Turbomachinery

High power turbopumps are frequently used to supply propellants to the combustion chambers of rocket engines. Due to the high pressures and flow-rates required, turbopump components are subjected to harsh environments which include dynamic excitation due to random, sine, and acoustic vibration. Additionally, fluid-induced forces can couple with the dynamics of the structure resulting in flow induced instabilities (flutter). Structural response to these forms of excitation results in reduced fatigue life and increases the likelihood of an operational failure. Particle damping has been used successfully on vibration problems in the past by increasing the damping and therefore reducing the response to acceptable levels. Empirical methods have typically been employed to evaluate the performance of the particles in reducing the structural response. This report explores the use of finite element methods to estimate the effectiveness of particle damping in a typical non-rotating turbopump component. Axisymmetric harmonic models are used to estimate the increase in modal damping produced by the addition of particles in the cavity of an axisymmetric seal. Target modes of vibration are evaluated to quantify how the effective particle damping is altered by geometry changes in the seal design. A new method to predict the performance of particle dampers is developed and shown to provide more reasonable estimates of damping.

Ehrgott, R.↗

An At-Home Evaluation of a Light Intervention to Mitigate Sleep Inertia Symptoms

Introduction: Sleep inertia symptoms typically occur after waking from nocturnal sleep. Under laboratory settings, light exposure upon waking has been shown to improve alertness, mood, and vigilant attention. We investigated whether a field-deployable light-emitting device would help to improve alertness and working memory in a real-world setting. Methods: Thirty-five participants (18 female; 26.4 ± 6.0 y) completed an at-home, within-subject, randomized crossover study. Participants wore actiwatches during their normal sleep-wake schedule for five nights ahead of the adaptation and experimental nights. On the experimental night, participants performed baseline testing before their self-selected bedtime. Forty-five minutes after bedtime, participants received a phone call and were instructed to perform test bouts while wearing light-emitting glasses with the light either on (light condition) or off (control). A 3-minute descending subtraction task (DST) and the Karolinska Sleepiness Scale (KSS) were performed at +7, +17, +27, and +37 minutes after the call. Participants were then instructed to go back to sleep and were called 45 minutes after lights out to repeat the test bouts in the opposite condition. A series of mixed-effects models were performed with fixed effects of condition, test bout, and their interaction, and a random effect of participant. Condition order, sex, and baseline were included as covariates. Results: There was a significant effect of test bout for DST total responses (χ2 [3] = 17.42; p < .001) and total correct (χ2 [3] = 21.29; p < .001) with improved performance at +27 and +37 minutes compared to +7 minutes. Sex was a significant predictor for KSS (F1,30 = 10.26; p = .003), with females (8.20 ± 0.23) rating higher sleepiness than males (7.10 ± 0.25). There were no other significant effects for DST or KSS outcomes (p > .05). Conclusion: These results suggest that the intervention was not able to improve working memory or alertness under naturalistic at-home settings. Further analysis is needed to determine whether these results are applicable to other cognitive performance domains.

light↗