Search NASA⌕ Search

SEARCH · Search NASA

Results for “response surface methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Absolute Cavity Pyrgeometer to Measure the Absolute Outdoor Longwave Irradiance with Traceability to International System of Units, SI

This article describes a method of measuring the absolute outdoor longwave irradiance using an absolute cavity pyrgeometer (ACP), U.S. Patent application no. 13/049, 275. The ACP consists of domeless thermopile pyrgeometer, gold-plated concentrator, temperature controller, and data acquisition. The dome was removed from the pyrgeometer to remove errors associated with dome transmittance and the dome correction factor. To avoid thermal convection and wind effect errors resulting from using a domeless thermopile, the gold-plated concentrator was placed above the thermopile. The concentrator is a dual compound parabolic concentrator (CPC) with 180{sup o} view angle to measure the outdoor incoming longwave irradiance from the atmosphere. The incoming irradiance is reflected from the specular gold surface of the CPC and concentrated on the 11 mm diameter of the pyrgeometer's blackened thermopile. The CPC's interior surface design and the resulting cavitation result in a throughput value that was characterized by the National Institute of Standards and Technology. The ACP was installed horizontally outdoor on an aluminum plate connected to the temperature controller to control the pyrgeometer's case temperature. The responsivity of the pyrgeometer's thermopile detector was determined by lowering the case temperature and calculating the rate of change of the thermopile output voltage versus the changing net irradiance. The responsivity is then used to calculate the absolute atmospheric longwave irradiance with an uncertainty estimate (U{sub 95}) of {+-}3.96 W m{sup 02} with traceability to the International System of Units, SI. The measured irradiance was compared with the irradiance measured by two pyrgeometers calibrated by the World Radiation Center with traceability to the Interim World Infrared Standard Group, WISG. A total of 408 readings were collected over three different nights. The calculated irradiance measured by the ACP was 1.5 W/m{sup 2} lower than that measured by the two pyrgeometers that are traceable to WISG, with a standard deviation of {+-}0.7 W m{sup -2}. These results suggest that the ACP design might be used for addressing the need to improve the international reference for broadband outdoor longwave irradiance measurements.

14 SOLAR ENERGY↗

CIAM Climatological Isolation and Attraction Model–Climatological Lagrangian Coherent Structures

Matlab code to compute climatological Lagrangian Coherent Structures. Climatological Lagrangian Coherent Structures have been shown to be effective in identifying regions that persistently attract or isolate trajectories at the sea surface, while also identifying recurrent transport patterns and transport barriers. It is therefore known as the Climatological Isolation and Attraction Model within NETL DoE. This repository also includes the information necessary to replicate the cCLS published in the paper which is freely available at: https://www.nature.com/articles/s41598-018-23121-y The method is developed in: Duran, R., F. J. Beron-Vera, M. J. Olascoaga (2018). Extracting quasi-steady Lagrangian transport patterns from the ocean circulation: An application to the Gulf of Mexico. Scientific Reports, 8(1), 5218. https://www.nature.com/articles/s41598-018-23121-y The method is successfully evaluated with a large dataset of satellite-tracked drifters, and with a different ocean model in: Gough M.K., F. J. Beron-Vera, M. J. Olascoaga, J. Sheinbaum, J. Jouenno, R. Duran (2019). Persistent Lagrangian transport patterns in the northwestern Gulf of Mexico. J. Phys. Oceanogr., 49, 353–367, https://doi.org/10.1175/JPO-D-17-0207.1 and with floats and yet a different model in: Maslo, A., Azevedo Correia de Souza, J. M., Andrade-Canto, F., & Rodríguez Outerelo, J. (2020). Connectivity of deep waters in the Gulf of Mexico. Journal of Marine Systems, 203, 103267. https://doi.org/10.1016/j.jmarsys.2019.103267

CIAM↗

TRIPOLI-4{sup R} version 9 Shielding for the Shielding Community: Overview, Relevant Benchmarking for Shielding and Licensing Policy - Paper 49

This is a review paper of the Shielding only version of TRIPOLI-4. TRIPOLI-4 and TRIPOLI-4 S: TRIPOLI{sup R} represents a family of radiation transport codes using the Monte Carlo method (1,2). It has been continuously developed at CEA since the mid 60's. TRIPOLI-4{sup R}, being the fourth generation, has been developed starting from the mid 90's in C++. It tracks neutrons from 20 MeV down to 10{sup -5} eV, photons, electrons and positrons from 100 MeV to 1 keV, in 3D arbitrary geometries either in TRIPOLI{sup R} proprietary format or ROOT(4) format. It reads its continuous energy nuclear data from any evaluation in ENDF format, including but not limited to JEFF-3.1.1 and ENDF/BVII.0. It has various simulation modes, fixed-source (with or without fission), criticality, or both of them chained. A variety of tallies are available: averaged flux in a volume (track length and collision estimators), surface flux and current, point flux, reaction rates, deposited energy, dpa, pka, gamma spectroscopy, mesh tallies, tallies for criticality (k{sub eff}, beta eff, kinetic parameters). It provides the user with embedded response functions from IRDF and EAF as well. Several variance reduction techniques (3), including automated ones, make it particularly suitable to deep penetration problems (implicit capture, Russian roulette, exponential biasing with automatic estimation of the importance map). It may run in parallel, on single multi-core machines as well as heterogeneous networks of stations or massively parallel machines. It comes with productivity tools designed to speed-up the elaboration and verification of the input deck as well as the output analysis: 2D interactive display of geometry; 2D display of mesh tallies and collision sites; 3D input deck modeler; compatibility with ROOT tools to post-process TRIPOLI{sup R} outputs. Its V and V test base is made of more than 1000 internationally accepted benchmarks from ICSBEP and SINBAD (REPLICA, ASPIS, NESDIP) and covers all its application domains, including several shielding cases which will be detailed in the talk. TRIPOLI-4{sup R} is the reference Monte Carlo code for CEA, EDF, and also for AREVA for a number of applications. A 'Shielding-only' version has been designed to specifically answer the needs of the shielding community. It is distributed through the NEA Databank with a license for R and D, covering the fusion applications, whose terms are detailed in the paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

BISON validation of FeCrAl cladding mechanical failure during simulated reactivity-initiated accident conditions*

Here, a reactivity-initiated accident (RIA) is a postulated design basis accident in light water reactors (LWRs) in which a rapid reactivity insertion induces a fission rate increase and a fuel pellet temperature rise. During RIA, the fuel pellet thermally expands and may cause pellet-cladding mechanical interaction (PCMI). Separate effects PCMI tests were performed on C26M FeCrAl cladding tube samples, introducing biaxial stress via a well understood modified burst test (MBT) system. A high-speed camera in the MBT system captured the projections, covering a 360° view of the cladding deformation and enabling a digital image correlation (DIC) method to quantify the surface strains with high fidelity. Representative hot zero-power RIA mechanical loading conditions were applied to the sample, and the test duration ranged from 20 to 500 ms at an average temperature of 573 K. BISON finite element–based fuel performance code modeling was performed against the high-fidelity DIC data produced from the MBTs. Validation calculations were conducted with 2D models and systematically compared with test data of the burst time, burst pressure, burst hoop strains, and hoop strain rates. Based on the behaviors from the separate effects test, BISON calculations satisfactorily predicted the cladding deformation behaviors. Sensitivity analysis was conducted to identify highly influential mechanical properties responsible for the cladding failure behavior during the MBT experiments. The results highlight the significance of the cladding's mechanical strength in governing cladding strain, followed by the significance of the mechanical interactions between the pellet and the cladding.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nominations for the 2017 NNSA Pollution Prevention Awards

In the field of nuclear forensics, one of the biggest challenges is to dissolve postdetonation debris for analysis. Debris generated after a nuclear detonation is a glassy material that is difficult to dissolve with chemicals. Traditionally, concentrated nitric acid, hydrofluoric acid, or sulfuric acid are employed during the dissolution. These acids, due to their corrosive nature, are not suitable for in-field/on-site sample preparations. Uranium oxides are commonly present in nuclear fuel processing plants and nuclear research facilities. In uranium oxides, the level of uranium isotope enrichment is a sensitive indicator for nuclear nonproliferation and is monitored closely by the International Atomic Energy Agency (IAEA) to ensure there is no misuse of nuclear material or technology for nuclear weapons. During an IAEA on-site inspection at a facility, environmental surface swipe samples are collected and transported to the IAEA headquarters or network of analytical laboratories for further processing. Uranium oxide particles collected on the swipe medium are typically dissolved with inorganic acids and are then analyzed for uranium isotopic compositions. To improve the responsiveness of on-site inspections, in-field detection techniques have been recently explored. However, in-field analysis is bottlenecked by time-consuming and hazardous dissolution procedures, as corrosive inorganic acids must be used. Corrosive chemicals are difficult to use in the field due to personnel safety considerations, and the transportation of such chemicals is highly regulated. It was therefore necessary to develop fast uranium oxide dissolution methods using less hazardous chemicals in support of the rapid infield detection of anomalies in declared nuclear processes.

54 ENVIRONMENTAL SCIENCES↗

Bacteria-Mineral Interactions on the Surfaces of Metal-Resistant Bacteria

The extraordinary ability of indigenous microorganisms, like metal-resistant bacteria, for biotransformation of toxic compounds is of considerable interest for the emerging area of environmental bioremediation. However, the underlying mechanisms by which metal-resistant bacteria transform toxic compounds are currently unknown and await elucidation. The project's objective was to study stress-induced responses of metal-resistant bacteria to environmental changes and chemical stimulants. This project involved a multi-institutional collaboration of our LLNL group with the group of Dr. H.-Y. Holman (Lawrence Berkeley National Laboratory). In this project, we have utilized metal-resistant bacteria Arthrobacter oxydans as a model bacterial system. We have utilized atomic force microscopy (AFM) to visualize for the first time at the nanometer scale formation of stress-induced structures on bacterial surfaces in response to Cr (VI) exposure. We have demonstrated that structure, assembly, and composition of these stress-induced structures are dependent on Cr (VI) concentrations. Our AFM observations of the appearance and development of stress-induced layers on the surfaces of Arthrobacter oxydans bacteria exposed to Cr (VI) were confirmed by Dr. Holman's biochemical, electron microscopy, and synchrotron infrared spectromicroscopy studies. In general, in vitro imaging of live microbial and cellular systems represents one of the most challenging issues in application of AFM. Various approaches for immobilization of bacteria on the substrate for in vitro imaging were tested in this project. Imaging of live bacteria was achieved, however further optimization of experimental methods are needed for high-resolution visualization of the cellular environmental structural dynamics by AFM. This project enhanced the current insight into molecular architecture, structural and environmental variability of bacterial systems. The project partially funded research for two book chapters (1,2), and we anticipate one more publication (3). The publications describe development of methods and results of studies of structural dynamics of metal-resistant bacteria that contribute to more comprehensive understanding of the architecture, function, and environmental dynamics of bacterial and cellular systems. The results of this LDRD were presented in invited talks and contributed presentations at five national and international conferences and five seminar presentations at the external institutions. These included invited talks at the conferences of Gordon Research, Materials Research and American Chemical Societies. Our scientific results and methodologies developed in this project enabled us to receive new funding for the multiyear project 'Chromium transformation pathways in metal-reducing bacteria' funded by the University of California Lab Fees Program ($500,000, 5/1/09 - 4/30/2012), with our proposal being ranked 1st from a total of 138 in the Earth, Energy, Environmental & Space Sciences panel.

59 BASIC BIOLOGICAL SCIENCES↗

Linear and nonlinear light scattering and absorption in free-electron nanoclusters with diffuse surface: General considerations and linear response

Both linear and nonlinear scattering and absorption of a laser pulse by spherical nanoclusters with free electrons and with a diffuse surface are considered in the collisionless hydrodynamics approximation. The developed model of forced collective motion of electrons confined to a cluster permits one consistently to introduce into the theory all the sources of nonlinearity, as well as the inhomogeneity of the cluster near its boundary. Two different perturbation theories corresponding to different laser intensity ranges are developed in this context, and both cold metal clusters and hot laser-heated or -ionized clusters are considered within the same approach. In the present article, after developing the full nonlinear model, the linear response to the laser field of the free-electron cluster with diffuse surface is investigated in detail, especially the properties of the linear Mie resonance (width and position). Under certain conditions, depending on the various cluster parameters secondary resonances are found. The properties of resonance-enhanced third-order harmonic generation and nonlinear laser absorption and their dependence on the shape of the diffuse surface will be presented separately.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optimization of Beidellite/Polyaniline Production Conditions by Central Composite Design for Removal of Acid Yellow 194

In the adsorption process, the adsorbent structure and its interaction with wastewater are the main determinant of the process efficiency. For this reason, the correct selection of the production conditions for the produced adsorbents is critical. In this study, the reaction time and the concentration of acid, oxidant, substrate, and monomer were selected as independent variables which effect the structure of the polyaniline based composite material. These production variables of polyaniline/beidellite (PANI/BEI) composites were designed by response surface methodology (RSM). According to RSM, 46 different PANI/BEI composites were synthesized and were used as an adsorbent in the removal of acid yellow 194. Thus, the optimum PANI/BEI production conditions were determined. After the identification of the optimum PANI/BEI production conditions, the effect of adsorption conditions such as pH, mixing time, and dye concentration were studied by batch experiments. The maximum adsorption capacity was obtained as 123 (mg g{sup −1}) at the T = 25 °C, t = 24 h, pH 3, m{sub s} = 0.15 g adsorbent, V{sub s} = 50 ml dye solution, and ω = 200 rpm. The results presented in this study revealed that the central composite design is a suitable method to optimize the production conditions of PANI/BEI and the prepared PANI/BEI composites has an important potential as an adsorbent for the removal of metal-complex dyes such as AY194. In addition, the polymerization of aniline and the removal of dye were confirmed by different analytical techniques such as BET, XRD, SEM, and EDAX.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Exploring Approaches for Accelerated Mass Spectrometric Detection of Fluorochemicals from Aqueous Solutions Using Indirect, Adsorbent-Facilitated Desorption Ionization

There is a growing need for rapid, low-cost analytical tools to screen water supplies for persistent contaminants. Due to their ubiquitous presence in the environment and their detrimental effects on human health, there is a public interest in widespread testing for perfluoroalkyl substances (PFAS). However, the most common methods for PFAS analysis can be time-intensive, requiring a preconcentration step followed by liquid chromatography–mass spectrometry (LC–MS), and are cost-prohibitive for most members of the public. To address these challenges, this study explores a novel method for rapid analysis of aqueous analytes by concentrating analytes on solid adsorbents and detecting them using mass spectrometric analysis via desorption ionization directly from the adsorbent surface. We demonstrate this general approach of indirect solution analysis (ISA) with desorption electrospray ionization (ISA-DESI) and laser desorption ionization (ISA-LDI). Various adsorbent materials were screened, including commercial mesoporous carbons, alumina, and metal–organic frameworks (MOFs). Using ISA-DESI, we consistently detect concentrations as low as 5–100 parts per trillion (ppt) for perfluorooctanoic acid (PFOA) and 10–100 ppt for perfluoroundecanoic acid (PFUnDA). This approach enables rapid detection in under 5 min, making it suitable for applications requiring trace detection with fast response times. We further demonstrate the use of ISA-DESI on a range of environmentally relevant contaminants. Advantages of this indirect solution analysis approach include simplified sample preparation, accelerated analysis, and low cost with readily available materials, making it a promising tool to accelerate mass spectrometric PFAS detection for identifying contaminated sites, performing laboratory studies, and monitoring industrial waste streams.

Bays, Nathan Robert [Sandia National Laboratories ↗

Application of gas-coupled laser acoustic detection to gelatins and underwater sensing

Gas-coupled Laser Acoustic Detection (GCLAD) has been used as a method to sense ultrasound waves in materials without contact of the material surface. To sense the waveform, a laser beam is directed parallel to the material surface and displaced or deflected when the radiated waveform traverses the beam. We present recent tests that demonstrate the potential of using this technique for detecting ultrasound in gelatin phantoms and in water. As opposed to interferometric detection, GCLAD operates independently of the optical surface properties of the material. This allows the technique to be used in cases where the material is transparent or semi-transparent. We present results on sensing ultrasound in gelatin phantoms that are used to mimic biological materials. As with air-coupled transducers, the frequency response of GCLAD at high frequencies is limited by the high attenuation of ultrasound in air. In contrast, water has a much lower attenuation. Here we demonstrate the use of a GCLAD-like system in water, measuring the directivity response at 1 MHz and sensing waveforms with higher frequency content.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of LiMn 2 O 4 cathodes by electrochemical strain microscopy

Electrochemical strain microscopy (ESM) is a scanning probe microscopy(SPM) method in which the local electrodiffusion is probed via application of AC voltage to the SPM tip and registration of resulting electrochemical strain. In this study, we implemented ESM to measure local strain in bulk LiMn 2 O 4 cathodes of a commercial Li-battery in different states of charge to investigate distribution of Li-ion mobility and concentration. Ramped AC ESM imaging and voltage spectroscopy were used to find the most reliable regime of measurements allowing separating and diminishing different contributions to ESM. This is not a trivial task due to complex geometry of the sample and various obstacles resulting in less predictable contributions of different origins into ESM response: electrostatic tip–surface interactions, charge injection, electrostriction, and flexoelectricity. Finally, understanding and control of these contributions is an important step towards quantitative interpretation of ESM data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Velocity distribution function of sputtered gallium atoms during inductively coupled argon plasma treatment of a GaAs surface

A GaN laser diode at 403.3 nm is used to measure the velocity distribution function (vdf) of Ga atoms sputtered from a radio-frequency biased GaAs substrate in a low pressure inductively coupled plasma (ICP) argon discharge. To investigate both perpendicular (V{sub z} normal to wafer) and longitudinal (V{sub x} parallel to wafer) velocity components, laser induced fluorescence (LIF) measurements are performed in the z direction and atomic absorption spectroscopy (AAS) in the x direction. The longitudinal vdf of Ga sputtered atoms is very close to a Lorentzian function with V{sub x} comprised between 0 and 7500 m s{sup -1}, while the perpendicular velocities V{sub z} can reach 10 000 m s{sup -1}. Experimental results are compared to molecular dynamics (MD) simulations of Ar{sup +} ion sputtering of GaAs under 200 eV bombardment. MD predictions and experiments are in fairly good agreement, which confirms the existence of products sputtered from the surface with kinetic energies larger than 10 eV. In etching processes dominated by physical bombardment, these energetic atoms could alter passivation layers on sidewalls and be responsible for defects observed in nanodevices. The best fit of the Doppler-broadened LIF and AAS profiles with the vdfs predicted by sputtering theory allows one to estimate the surface binding energy of Ga atoms in GaAs, E{sub b}, to be around 3 eV.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On the importance of species immiscibility in mixing-layer dynamics at supercritical pressures

The mixing dynamics of injected propellants is a key factor in determining the ignition performance and combustion-instability response of rocket engines, internal combustion engines, and gas turbines. A key source of uncertainty in the prediction of phase-exchange dynamics is the immiscibility of the injected propellants at supercritical pressure conditions, which induces liquid/vapor phase separation and surface-tension dynamics. While experimental observations indicate the presence of liquid/vapor interfacial structures, this interfacial dynamics is typically neglected in numerical analyses. To address this issue, the objective of the present study is to systematically evaluate the importance of species immiscibility on the phase-exchange dynamics of cryogenic LOX/GH2 mixing layers at typical rocket engine injection conditions. This is accomplished by comparing simulations of (i) a recently developed interface-capturing Regularized-Interface Method (RIM) formulation, and (ii) the commonly employed Diffuse-Interface Method (DIM) formulation. Analysis shows that the interfacial dynamics significantly impact the atomization and mixing of the propellants in the near-injector region, which is not captured by the DIM formulation. The findings of this study extend to other immiscible injection systems, such as LOX/kerosene and hydrocarbon-fuel/air, thereby highlighting the importance of resolving species immiscibility in simulating high-pressure combustion engines.

diffused-interface method↗

Functionalized mesoporous silica materials for molsidomine adsorption: Thermodynamic study

A series of unmodified and organically modified mesoporous silica materials was prepared. The unmodified mesoporous silica was synthesized via sol–gel synthesis in the presence of D-glucose as pore-forming agent. The functionalized by phenyl, aminopropyl and mercaptopropyl groups silica materials were prepared via grafting. The fabricated adsorbent materials were characterized by Fourier transform infrared spectroscopy (FTIR) analysis, N{sub 2} adsorption/desorption and elemental analysis methods. Then their adsorption properties for mesoionic dug molsidomine were investigated at 290–313 K and physiological pH value. Thermodynamic parameters of molsidomine adsorption on the synthesized materials have been calculated. The obtained results showed that the adsorption process of molsidomine on the phenyl modified silica is the most quantitatively and energetically favorable. The unmodified and mercaptopropyl modified silica materials exhibit significantly higher adsorption capacities and energies for molsidomine than the aminopropyl modified sample. The effects are discussed from the viewpoint of nature of specific interactions responsible for the adsorption. - Graphical abstract: Comparative analysis of the thermodynamic characteristics of molsidomine adsorption showed that the adsorption process on mesoporous silica materials is controlled by chemical nature of surface functional groups. Molsidomine adsorption on the phenyl modified silica is the most quantitatively and energetically favorable. Taking into account ambiguous nature of mesoionic compounds, it was found that molsidomine is rather aromatic than dipolar. Display Omitted - Highlights: • Unmodified and organically modified mesoporous silica materials were prepared. • Molsidomine adsorption on the silica materials was studied. • Phenyl modified silica shows the highest adsorption capacity and favorable energy. • Molsidomine exhibits the lowest affinity to aminopropyl modified silica.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rationalizing the suitability of rhodamines as chromophores in dye-sensitized solar cells: A systematic molecular design study

Here, rhodamines are chromophores that are employed in many dye applications. Their strong optical absorption in the visible region of the electromagnetic spectrum renders them attractive dye candidates for dye-sensitized solar cells (DSCs). However, they have not yet been systematically tested in DSCs as single- or co-sensitizers. Recent advances in concerted experimental and computational workflows involving molecular design protocols can afford a better understanding of the molecular origins of the optoelectronic properties in these sensitizers. Herein, we examine the suitability of rhodamines R560 (1), R575 (2), R590 (3), R610 (4), R620 (5), R640 (6), and R3B (7) as chromophores in co-sensitized DSCs. Our study follows a stepwise approach. Initially, structural and optical properties of the dyes are investigated by experimental and computational methods to reveal structure-property relationships and other useful features for DSC applications. Subsequently, 1-7 are investigated at the dye···TiO 2 interface, both by calculations of dye-adsorption onto the surface of a modeled (TiO 2 ) 9 cluster, and by experimental studies of dye-adsorption on TiO 2 . For that purpose, a selection of rhodamine dyes are paired together (1 and 5) and (1 and 7) for co-sensitization, among which 5 is also co-adsorbed with a fluorescein dye in order to explore chemical compatibility factors. The best dye candidates are identified from the findings of these adsorption studies in terms of dye aggregation, anchoring modes, and panchromatic response. Despite their promising dye…TiO 2 adsorption and optical prospects, our results show that rhodamines lack a suitable intramolecular charge transfer pathway for dye-to-TiO 2 electron injection to occur, thus precluding their photovoltaic function as DSC dyes. Our results are then assessed against ostensibly disparate reports of rhodamines performing successfully in DSC devices; this comparison necessitated the internal reproduction of previously reported co-sensitization experiments on 2 with the industrial standard reference dye, N3. We achieve reconciliation between our results and those in the literature by reasoning that while rhodamines cannot deliver photovoltaic function in DSCs in their own right, they can either act to facilitate or deplete the photovoltaic output of a DSC indirectly by affecting the TiO 2 adsorption prospects of a photovoltaic-active dye with which a rhodamine is co-sensitized.

14 SOLAR ENERGY↗

Environmental Remediation Activities in Japan Following the Fukushima Dai-ichi Reactor Incident - 12603

In March 2011, the Fukushima Dai-ichi reactor power plant was crippled by the Great Pacific earthquake and subsequent tsunami. Much of the focus in the news was on the reactor site itself as the utility company (TEPCO), the Japanese government, and experts from around the world worked to bring the damaged plants into a safe shutdown condition and stem the release of radioactivity to the environment. Most of the radioactivity released was carried out to sea with the prevailing winds. Still, as weather patterns changed and winds shifted, a significant plume of radioactive materials released from the plant deposited in the environment surrounding the plant, contaminating large land areas of the Fukushima Prefecture. The magnitude of the radiological impact to the surrounding environmental is so large that the Japanese government has had to reevaluate the meaning of 'acceptably clean'. In many respects, 'acceptably clean' cannot be a one-size-fits-all standard. The economics costs of such an approach would make impossible what is already an enormous and costly environmental response and remediation task. Thus, the Japanese government has embarked upon an approach that is both situation-specific and reasonably achievable. For example, the determination of acceptably clean for a nursery school or kindergarten play yard may be different from that for a parking lot. The acceptably clean level of residual radioactivity in the surface soil of a rice paddy is different from that in a forested area. The recognized exposure situation (scenario) thus plays a large role in the decision process. While sometimes complicated to grasp or implement, such an approach does prioritize national resources to address environment remediation based upon immediate and significant risks. In addition, the Japanese government is testing means and methods, including advanced or promising technologies, that could be proven to be effective in reducing the amount of radioactivity in the environment beyond a fixed, concentration based limit. Essentially, the definition of acceptably clean includes the concept of reasonably achievable, given the available technology, means and methods, and the cost to implement such. The Japanese government recently issued three technology demonstration contracts expressly designed to test and evaluate the available technologies, means, and methods, which, if implemented, might produce the greatest risk reduction from environmental contamination for the best value. One of the Japanese contract holders, Obayashi JV, has teamed with AMEC to demonstrate the applicability and capabilities of the Orion ScanPlot{sup SM} and ScanSort{sup SM} technologies in radiologically impacted towns both inside and immediately outside the 20 km restricted zone. This presentation provides some unique images and informative insight into the environmental radioactive impacts in and around the exclusion zone. It will provide a look at one element of the Japanese government?s efforts to achieve the greatest risk reduction that is reasonably achievable. The Orion ScanPlot{sup SM} and ScanSort{sup SM} are being used with success on the Japan Town Demonstration Project to assess pre-remedial action contamination levels, document the post-remedial action contamination levels and to precisely measure and segregate excavated soils based on their radioactive content and the prescribed segregation limits (DCS). Initial results suggest that these technologies could provide capabilities to the remedial action efforts that would result in considerable improvements in field data certainty and compliance with remedial objectives while reducing overall costs. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

2D Spatial Frequency Considerations in Comparing 1D Power Spectral Density Measurements

The frequency footprint of ID and 2D profiling instruments needs to be carefully considered in comparing ID surface roughness spectrum measurements made by different instruments. Contributions from orthogonal direction frequency components can not be neglected. The use of optical profiling instruments is ubiquitous in the measurement of the roughness of optical surfaces. Their ease-of-use and non-contact measurement method found widespread use in the optics industry for measuring the quality of delicate optical surfaces. Computerized digital data acquisition with these instruments allowed for quick and easy calculation of surface roughness statistics, such as root-mean-square (RMS) roughness. The computing power of the desktop computer allowed for the rapid conversion of spatial domain data into the frequency domain, enabling the application of sophisticated signal processing techniques to be applied to the analysis of surface roughness, the most powerful of which is the power spectral density (PSP) function. Application of the PSD function to surface statistics introduced the concept of 'bandwidth-limited' roughness, where the value of the RMS roughness depends critically upon the spatial frequency response of the instrument. Different instruments with different spatial frequency response characteristics give different answers when measuring the same surface.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulated effect of defect volume and location on very high cycle fatigue of laser beam powder bed fused AlSi10Mg

This study quantifies the interaction between volumetric defect location and size on the very high cycle fatigue (VHCF) of laser beam powder bed fused (LB-PBF) AlSi10Mg. Crystal plasticity finite element method (CPFEM) simulations were used to investigate the effects of defect location and size on the driving force for crack initiation. The CPFEM model was calibrated against uniaxial and cyclic experimental data of LB-PBF AlSi10Mg. Defect characteristics were informed by experimental data from the specimens produced in various geometries to create realistic representative volume elements (RVEs) with equivalent volume fractions of defects. By embedding defects of varying sizes and locations within the RVEs, fatigue indicator parameters (FIPs) were calculated to analyze the impact of defects’ characteristics on fatigue performance. Different combinations of defect volume and locations were generated for various microstructure instantiations, providing insight into extreme value fatigue responses. Larger defect volumes located on free surfaces consistently generated the highest FIPs, suggesting defect size and boundary proximity intensify stress concentration effects. RVEs with multiple smaller defects produced lower FIPs than those with single large critical defects. These findings underscore the critical role of defect characteristics on fatigue life, providing a foundation for future predictive modeling in fatigue-sensitive AM applications.

AlSi10Mg↗