Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

Design and Evaluation of a Tethered, Open Port Sampling Interface for Liquid Extraction-Mass Spectrometry Chemical Analysis

Presented in this work is a tethered, liquid-extraction-sampling interface designed for the mass spectrometric surface sampling/analysis of 3D objects. The tethered, open port sampling interface (TOPSI) incorporates a vacuum line between the sampling probe and ionization source, which enables the ability for an extended, tethered sample transfer line. Herein, several designs of the hand-held TOPSI are presented and evaluated on the basis of the analytical metrics of analyte transport time, peak width, and analyte sensitivity. The best analytical metrics were obtained with capillary flow resistances arranged in a particular order and the vacuum region set at 6.2 kPa. This TOPSI design incorporated a transfer capillary 1 m in length, while retaining a fast analyte transport time (12 s), short signal peak width (5 s baseline-to-baseline), and high analyte signal at 90% of that obtained with a regular open port sampling interface (OPSI). The hand-held TOPSI was demonstrated for the characterization of extracted small molecules and metabolites from the surface of mint and rosemary leaves.

47 OTHER INSTRUMENTATION↗

Improved explosive collection and detection with rationally assembled surface sampling materials

Sampling and detection of trace explosives is a key analytical process in modern transportation safety. In this work we have explored some of the fundamental analytical processes for collection and detection of trace level explosive on surfaces with the most widely utilized system, thermal desorption IMS. The performance of the standard muslin swipe material was compared with chemically modified fiberglass cloth. The fiberglass surface was modified to include phenyl functional groups. When compared to standard muslin, the phenyl functionalized fiberglass sampling material showed better analyte release from the sampling material as well as improved response and repeatability from multiple uses of the same swipe. The improved sample release of the functionalized fiberglass swipes resulted in a significant increase in sensitivity. Various physical and chemical properties were systematically explored to determine optimal performance. The results herein have relevance to improving the detection of other explosive compounds and potentially to a wide range of other chemical sampling and field detection challenges.

Explosive detection↗

Note: A sample holder design for sensitive magnetic measurements at high temperatures in a magnetic properties measurement system

A sample holder design for high temperature measurements in a commercial MPMS SQUID magnetometer from Quantum Design is presented. It fulfills the requirements for the simultaneous use of the oven and reciprocating sample option (RSO) options, thus allowing sensitive magnetic measurements up to 800 K. Alternating current susceptibility can also be measured, since the holder does not induce any phase shift relative to the ac driven field. It is easily fabricated by twisting Constantan Copyright-Sign wires into a braid nesting the sample inside. This design ensures that the sample be placed tightly into a tough holder with its orientation fixed, and prevents any sample displacement during the fast movements of the RSO transport, up to high temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact cold stage for micro-computerized tomography imaging of chilled or frozen samples

High resolution X-ray microCT (computerized tomography) can be used to image a variety of objects, including temperature-sensitive materials. In cases where the sample must be chilled or frozen to maintain sample integrity, either the microCT machine itself must be placed in a refrigerated chamber, or a relatively expensive commercial cold stage must be purchased. We describe here the design and construction of a low-cost custom cold stage suitable for use in a microCT imaging system. Our device uses a boron nitride sample holder, two-stage Peltier cooler, fan-cooled heat sink, and electronic controller to maintain sample temperatures as low as −25 °C ± 0.2 °C for the duration of a tomography acquisition. The design does not require modification to the microCT machine, and is easily installed and removed. Our custom cold stage represents a cost-effective solution for refrigerating CT samples for imaging, and is especially useful for shared equipment or machines unsuitable for cold room use.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ANALYZING STAR CLUSTER POPULATIONS WITH STOCHASTIC MODELS: THE HUBBLE SPACE TELESCOPE/WIDE FIELD CAMERA 3 SAMPLE OF CLUSTERS IN M83

The majority of clusters in the universe have masses well below 10{sup 5} M{sub Sun }. Hence, their integrated fluxes and colors can be affected by the presence or absence of a few bright stars introduced by stochastic sampling of the stellar mass function. Specific methods are being developed to extend the analysis of cluster energy distributions into the low-mass regime. In this paper, we apply such a method to real observations of star clusters, in the nearby spiral galaxy M83. We reassess the ages and masses of a sample of 1242 clusters for which UBVIH{alpha} fluxes were obtained from observations with the Wide Field Camera 3 instrument on board the Hubble Space Telescope. Synthetic clusters with known properties are used to characterize the limitations of the method (valid range and resolution in age and mass, method artifacts). The ensemble of color predictions of the discrete cluster models are in good agreement with the distribution of observed colors. We emphasize the important role of the H{alpha} data in the assessment of the fraction of young objects, particularly in breaking the age-extinction degeneracy that hampers an analysis based on UBVI data only. We find the mass distribution of the cluster sample to follow a power law of index -2.1 {+-} 0.2, and the distribution of ages a power law of index -1.0 {+-} 0.2 for log (M/ M{sub Sun }) > 3.5, and ages between 10{sup 7} and 10{sup 9} yr. An extension of our main method, which makes full use of the probability distributions of age and mass obtained for the individual clusters of the sample, is explored. It produces similar power-law slopes and will deserve further investigation. Although the properties derived for individual clusters significantly differ from those obtained with traditional, non-stochastic models in about 30% of the objects, the first-order aspect of the age and mass distributions is similar to those obtained previously for this M83 sample in the range of overlap of the studies. We extend the power-law description to lower masses with better mass and age resolution and without most of the artifacts produced by the classical method.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmic ray sampling of a clumpy interstellar medium

How cosmic rays sample the multi-phase interstellar medium (ISM) in starburst galaxies has important implications for many science goals, including evaluating the cosmic ray calorimeter model for these systems, predicting their neutrino fluxes, and modeling their winds. Here, we use Monte Carlo simulations to study cosmic ray sampling of a simple, two-phase ISM under conditions similar to those of the prototypical starburst galaxy M82. The assumption that cosmic rays sample the mean density of the ISM in the starburst region is assessed over a multi-dimensional parameter space where we vary the number of molecular clouds, the galactic wind speed, the extent to which the magnetic field is tangled, and the cosmic ray injection mechanism. We evaluate the ratio of the emissivity from pion production in molecular clouds to the emissivity that would be observed if the cosmic rays sampled the mean density, and seek areas of parameter space where this ratio differs significantly from unity. The assumption that cosmic rays sample the mean density holds over much of parameter space; however, this assumption begins to break down for high cloud density, injection close to the clouds, and a very tangled magnetic field. We conclude by evaluating the extent to which our simulated starburst region behaves as a proton calorimeter and constructing the time-dependent spectrum of a burst of cosmic rays.

79 ASTRONOMY AND ASTROPHYSICS↗

Pi sampling: a methodical and flexible approach to initial macromolecular crystallization screening

Pi sampling, derived from the incomplete factorial approach, is an effort to maximize the diversity of macromolecular crystallization conditions and to facilitate the preparation of 96-condition initial screens. The Pi sampling method is derived from the incomplete factorial approach to macromolecular crystallization screen design. The resulting ‘Pi screens’ have a modular distribution of a given set of up to 36 stock solutions. Maximally diverse conditions can be produced by taking into account the properties of the chemicals used in the formulation and the concentrations of the corresponding solutions. The Pi sampling method has been implemented in a web-based application that generates screen formulations and recipes. It is particularly adapted to screens consisting of 96 different conditions. The flexibility and efficiency of Pi sampling is demonstrated by the crystallization of soluble proteins and of an integral membrane-protein sample.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Alignment of sample position and rotation during in situ synchrotron X-ray micro-diffraction experiments using a Laue cross-correlation approach

Laue micro-diffraction has proven to be able to reveal material properties at the sub-grain scale for many polycrystalline materials and is now routinely available at several synchrotron facilities, providing an approach for nondestructive three-dimensional probing of the microstructures and mechanical states of materials. However, for in situ experiments, maintaining the positioning of the sample throughout the experiment, to achieve a good alignment of the characterized volumes, is a challenging issue. The aim of the present work is to address this problem by developing an approach based on digital image correlation of focused-beam Laue diffraction patterns. The method uses small changes in the diffraction signal as a focused X-ray beam is scanned over a surface region to allow corrections to be made for both sample lateral movement and rotation. The method is demonstrated using a tensile deformation experiment on an Al sample with 2.5 µm average grain size. The results demonstrate an accuracy of 0.5 µm for sample position registration and a precision in sample rotation of ~0.01°. Finally, the proposed method is fast to implement and does not require the use of additional surface markers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Power Grid Reliability Estimation via Adaptive Importance Sampling

Electricity production currently generates approximately 25% of greenhouse gas emissions in the USA. Thus, increasing the amount of renewable energy is a key step to carbon neutrality. However, integrating a large amount of fluctuating renewable generation is a significant challenge for power grid operating and planning. Grid reliability, i.e., an ability to meet operational constraints under power fluctuations, is probably the most important of them. In this letter, we propose computationally efficient and accurate methods to estimate the probability of line overflow, i.e., reliability constraints violation, under a known distribution of renewable energy generation. To this end, we investigate an importance sampling approach, a flexible extension of Monte-Carlo methods, which adaptively changes the sampling distribution to generate more samples near the reliability boundary. The approach allows to estimate overload probability in real-time based only on a few dozens of random samples, compared to thousands required by the plain Monte-Carlo. Our study focuses on high voltage direct current power transmission grids with linear reliability constraints on power injections and line currents. Herein, we propose a novel theoretically justified physics-informed adaptive importance sampling algorithm and compare its performance to state-of-the-art methods on multiple IEEE power grid test cases.

power system faults↗

Sample Complexity of Power System State Estimation Using Matrix Completion

In this paper, we propose an analytical framework to quantify the amount of data samples needed to obtain accurate state estimation in a power system - a problem known as sample complexity analysis in computer science. Motivated by the increasing adoption of distributed energy resources into the distribution-level grids, it becomes imperative to estimate the state of distribution grids in order to ensure stable operation. Traditional power system state estimation techniques mainly focus on the transmission network which involve solving an overdetermined system and eliminating bad data. However, distribution networks are typically underdetermined due to the large number of connection points and high cost of pervasive installation of measurement devices. In this paper, we consider the recently proposed state-estimation method for underdetermined systems that is based on matrix completion. In particular, a constrained matrix completion algorithm was proposed, wherein the standard matrix completion problem is augmented with additional equality constraints representing the physics (namely power-flow constraints). We analyze the sample complexity of this general method by proving an upper bound on the sample complexity that depends directly on the properties of these constraints that can lower number of needed samples as compared to the unconstrained problem. To demonstrate the improvement that the constraints add to state estimation, we test the method on a 141-bus distribution network case study and compare it to the traditional least squares minimization state estimation method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

False-Negative Rate and Recovery Efficiency Performance of a Validated Sponge Wipe Sampling Method

Recovery of spores from environmental surfaces varies due to sampling and analysis methods, spore size and characteristics, surface materials, and environmental conditions. Tests were performed to evaluate a new, validated sponge wipe method using Bacillus atrophaeus spores. Testing evaluated the effects of spore concentration and surface material on recovery efficiency (RE), false-negative rate (FNR), limit of detection (LOD), and their uncertainties. Ceramic tile and stainless steel had the highest mean RE values (48.9 and 48.1%, respectively). Faux leather, vinyl tile, and painted wood had mean RE values of 30.3, 25.6, and 25.5, respectively, while plastic had the lowest mean RE (9.8%). Results show roughly linear dependences of RE and FNR on surface roughness, with smoother surfaces resulting in higher mean REs and lower FNRs. REs were not influenced by the low spore concentrations tested (3.10x10^-3 to 1.86 CFU/cm^2). Stainless steel had the lowest mean FNR (0.123), and plastic had the highest mean FNR (0.479). The LOD90 (>1 CFU detected 90% of the time) varied with surface material, from 0.015 CFU/cm^2 on stainless steel up to 0.039 on plastic. It may be possible to improve sampling results by considering surface roughness in selecting sampling locations and interpreting spore recovery data. Further, FNR values (calculated as a function of concentration and surface material) can be used presampling to calculate the numbers of samples for statistical sampling plans with desired performance and postsampling to calculate the confidence in characterization and clearance decisions.

Anthrax↗

Trigger Detection for Adaptive Scientific Workflows Using Percentile Sampling

The increasing complexity of both scientific simulations and high-performance computing system architectures are driving the need for adaptive workflows, in which the composition and execution of computational and data manipulation steps dynamically depend on the evolutionary state of the simulation itself. Consider, for example, the frequency of data storage. Critical phases of the simulation should be captured with high frequency and with high fidelity for postanalysis; however, we cannot afford to retain the same frequency for the full simulation due to the high cost of data movement. We can instead look for triggers, indicators that the simulation will be entering a critical phase, and adapt the workflow accordingly. In this paper, we present a methodology for detecting triggers and demonstrate its use in the context of direct numerical simulations of turbulent combustion using S3D. We show that chemical explosive mode analysis (CEMA) can be used to devise a noise-tolerant indicator for rapid increase in heat release. However, exhaustive computation of CEMA values dominates the total simulation, and thus is prohibitively expensive. To overcome this computational bottleneck, we propose a quantile sampling approach. Our sampling-based algorithm comes with provable error/confidence bounds, as a function of the number of samples. Most importantly, the number of samples is independent of the problem size, and thus our proposed sampling algorithm offers perfect scalability. Our experiments on homogeneous charge compression ignition and reactivity controlled compression ignition simulations show that the proposed method can detect rapid increases in heat release, and its computational overhead is negligible. Our results will be used to make dynamic workflow decisions regarding data storage and mesh resolution in future combustion simulations.

97 MATHEMATICS AND COMPUTING↗

Ensemble approximate control variate estimators: Applications to multi-fidelity importance sampling.

The recent growth in multifidelity uncertainty quantification has given rise to a large set of variance reduction techniques that leverage information from model ensembles to provide variance reduction for estimates of the statistics of a high-fidelity model. In this paper we provide two contributions: (1) we utilize an ensemble estimator to account for uncertainties in the optimal weights of approximate control variate (ACV) approaches and derive lower bounds on the number of samples required to guarantee variance reduction; and (2) we extend an existing multifidelity importance sampling (MFIS) scheme to leverage control variates. Our approach directly addresses a limitation of many multifidelity sampling strategies that require the usage of pilot samples to estimate covariances. As such we make significant progress towards both increasing the practicality of approximate control variates—for instance, by accounting for the effect of pilot samples—and using multifidelity approaches more effectively for estimating low-probability events. The numerical results indicate our hybrid MFIS-ACV estimator achieves up to 50% improvement in variance reduction over the existing state-of-the-art MFIS estimator, which had already shown an outstanding convergence rate compared to the Monte Carlo method, on several problems of computational mechanics.

97 MATHEMATICS AND COMPUTING↗

Spatial Study 2021: Sample-Based Surface Water Chemistry and Organic Matter Characterization across Watersheds in the Yakima River Basin, Washington, USA (v3)

This dataset supports a broader study examining the drivers of spatial variability in sediment respiration rates in the Yakima River Basin. The dataset provides geochemistry and organic matter characterization data generated from samples collected during the same two-week period at 47 sites within multiple rivers throughout the Yakima River Basin in Washington, USA. Related sensor data are published at https://data.ess-dive.lbl.gov/datasets/doi:10.15485/1892054. This data package was originally published September 2022. It was updated May 2023 (modified files) and November 2024 (new and modified files). See the change history section in the readme for more details. This dataset is comprised of one main data folder containing (1) file-level metadata; (2) data dictionary; (3) field metadata; (4) dissolved inorganic carbon (DIC), dissolved organic carbon (DOC; reported as non-purgeable organic carbon; NPOC), total nitrogen (TN), total suspended solids (TSS), ions, and benzene polycarboxylic acid (BPCA) concentration and stable isotope data; (5) averaged values from water chemistry data; (6) surface water sampling protocol; (7) sensor protocol (8) readme; (9) methods codes; (10) international generic-sample number (IGSN) mapping file; and (11) folder of high resolution characterization of organic matter via 12 Tesla Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) through the Environmental Molecular Sciences Laboratory (EMSL; https://www.pnnl.gov/environmental-molecular-sciences-laboratory). This folder contains two subfolders, one containing the .xml data files and the other containing instructions for using Formultitude (https://github.com/PNNL-Comp-Mass-Spec/Formultitude) and an R script to process the data based on the user's specific needs. All files are .csv, .pdf, .R, .ref, or .xml. We thank the United States Forest Service, Washington Department of Natural Resources, Washington Department of Fish and Wildlife, Washington State Parks, Confederated Tribes and Bands of the Yakama Nation, and Cowiche Canyon Conservancy for access to field locations where these samples were collected. We also thank the Yakama Nation Tribal Council and Yakama Nation Fisheries for working with us to facilitate sample collection and optimization of data usage according to their values and worldview.

54 ENVIRONMENTAL SCIENCES↗

ANALYSIS OF SAMPLES FROM TANK 6F CHEMICAL CLEANING

Savannah River Remediation (SRR) is preparing Tank 6F for closure. The first step in preparing the tank for closure is mechanical sludge removal. In mechanical sludge removal, personnel add liquid (e.g., inhibited water or supernate salt solution) to the tank to form a slurry. They mix the liquid and sludge with pumps, and transfer the slurry to another tank for further processing. Mechanical sludge removal effectively removes the bulk of the sludge from a tank, but is not able to remove all of the sludge. In Tank 6F, SRR estimated a sludge heel of 5,984 gallons remained after mechanical sludge removal. To remove this sludge heel, SRR performed chemical cleaning. The chemical cleaning included two oxalic acid strikes, a spray wash, and a water wash. SRR conducted the first oxalic acid strike as follows. Personnel added 110,830 gallons of 8 wt % oxalic acid to Tank 6F and mixed the contents of Tank 6F with two submersible mixer pumps (SMPs) for approximately four days. Following the mixing, they transferred 115,903 gallons of Tank 6F material to Tank 7F. The SMPs were operating when the transfer started and were shut down approximately five hours after the transfer started. SRR collected a sample of the liquid from Tank 6F and submitted it to SRNL for analysis. Mapping of the tank following the transfer indicated that 2,400 gallons of solids remained in the tank. SRR conducted the second oxalic acid strike as follows. Personnel added 28,881 gallons of 8 wt % oxalic acid to Tank 6F. Following the acid addition, they visually inspected the tank and transferred 32,247 gallons of Tank 6F material to Tank 7F. SRR collected a sample of the liquid from Tank 6F and submitted it to SRNL for analysis. Mapping of the tank following the transfer indicated that 3,248 gallons of solids remained in the tank. Following the oxalic acid strikes, SRR performed Spray Washing with oxalic acid to remove waste collected on internal structures, cooling coils, tank top internals, and tank walls. The Acid Spray Wash was followed by a Water Spray Wash to remove oxalic acid from the tank internals. SRR conducted the Spray Wash as follows. Personnel added 4,802 gallons of 8 wt % oxalic acid to Tank 6F through the spray mast installed in Riser 2, added 4,875 gallons of oxalic acid through Riser 7, added 5,000 gallons of deionized water into the tank via Riser 2, and 5,000 gallons of deionized water into the tank via Riser 7. Following the Spray Wash, they visually inspected the tank and transferred 22,430 gallons of Tank 6F material to Tank 7F. SRR collected a sample of the liquid from Tank 6F and submitted it to SRNL for analysis. Following the Spray Wash and transfer, Savannah River Site (SRS) added 113,935 gallons of well water to Tank 6F. They mixed the tank contents with a single SMP and transferred 112,699 gallons from Tank 6F to Tank 7F. SRR collected a sample of the liquid from Tank 6F and submitted to SRNL for analysis. Mapping of the tank following the transfer indicated that 3,488 gallons of solids remained in the tank. Following the Water Wash, SRR personnel collected a solid sample and submitted it to SRNL for analysis to assess the effectiveness of the chemical cleaning and to provide a preliminary indication of the composition of the material remaining in the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sampling Within k-Means Algorithm to Cluster Large Datasets

Due to current data collection technology, our ability to gather data has surpassed our ability to analyze it. In particular, k-means, one of the simplest and fastest clustering algorithms, is ill-equipped to handle extremely large datasets on even the most powerful machines. Our new algorithm uses a sample from a dataset to decrease runtime by reducing the amount of data analyzed. We perform a simulation study to compare our sampling based k-means to the standard k-means algorithm by analyzing both the speed and accuracy of the two methods. Results show that our algorithm is significantly more efficient than the existing algorithm with comparable accuracy. Further work on this project might include a more comprehensive study both on more varied test datasets as well as on real weather datasets. This is especially important considering that this preliminary study was performed on rather tame datasets. Also, these datasets should analyze the performance of the algorithm on varied values of k. Lastly, this paper showed that the algorithm was accurate for relatively low sample sizes. We would like to analyze this further to see how accurate the algorithm is for even lower sample sizes. We could find the lowest sample sizes, by manipulating width and confidence level, for which the algorithm would be acceptably accurate. In order for our algorithm to be a success, it needs to meet two benchmarks: match the accuracy of the standard k-means algorithm and significantly reduce runtime. Both goals are accomplished for all six datasets analyzed. However, on datasets of three and four dimension, as the data becomes more difficult to cluster, both algorithms fail to obtain the correct classifications on some trials. Nevertheless, our algorithm consistently matches the performance of the standard algorithm while becoming remarkably more efficient with time. Therefore, we conclude that analysts can use our algorithm, expecting accurate results in considerably less time.

99 GENERAL AND MISCELLANEOUS↗

Final work plan : indoor air and ambient air sampling near the former CCC/USDA grain storage facility in Everest, Kansas.

The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility at the western edge of Everest, Kansas, from the early 1950s to the early 1970s. Sampling by the Kansas Department of Health and Environment (KDHE) in 1997 resulted in the detection of carbon tetrachloride in one domestic well (the Nigh well) northwest of the former facility. On behalf of the CCC/USDA, Argonne National Laboratory subsequently conducted a series of investigations to characterize the contamination (Argonne 2003, 2006a,b,c). Automatic, continuous monitoring of groundwater levels began in 2002 and is ongoing at six locations. The results have consistently indicated groundwater flow toward the north-northwest from the former CCC/USDA property to the Nigh property, then west-southwest from the Nigh property to the intermittent creek. Sitewide periodic groundwater and surface water sampling with analysis for volatile organic compounds (VOCs) began in 2008. Argonne's combined data indicate no significant downgradient extension of contamination since 2000. At present, the sampling is annual, as approved by the KDHE (2009) in response to a plan developed for the CCC/USDA (Argonne 2009). This document presents a plan for collecting indoor air samples in homes located along and adjacent to the defined extent of the carbon tetrachloride contamination. The plan was requested by the KDHE. Ambient air samples to represent the conditions along this pathway will also be taken. The purpose of the proposed work is to satisfy KDHE requirements and to collect additional data for assessing the risk to human health due to the potential upward migration of carbon tetrachloride and its primary degradation product (chloroform) into homes located in close proximity to the former grain storage facility, as well as along and within 100 ft laterally from the currently defined plume emanating from the former Everest facility. Investigation of the indoor air environment was not a defined objective during the previous investigations of the Everest site (Argonne 2003, 2006a,b,c) as they predated the more recent regulatory concern regarding potential health risks associated with the vapor contaminant pathway.

54 ENVIRONMENTAL SCIENCES↗

Characteristics of KE Basin Sludge Samples Archived in the RPL - 2007

Samples of sludge were collected from the K East fuel storage basin (KE Basin) floor, contiguous pits (Weasel Pit, North Load Out Pit, Dummy Elevator Pit, and Tech View Pit), and fuel storage canisters between 1995 and 2003 for chemical and radionuclide concentration analysis, physical property determination, and chemical process testing work. Because of the value of the sludge in this testing and because of the cost of obtaining additional fresh samples, an ongoing program of sludge preservation has taken place with the goals to track the sludge identities and preserve, as well as possible, the sludge composition by keeping the sludge in sealed jars and maintaining water coverage on the sludge consistent with the controlling Fluor Hanford (FH) Sampling and Analysis plans and FH contracts with the Pacific Northwest National Laboratory (PNNL). This work was originally initiated to provide material for planned hydrothermal treatment testing in accordance with the test plan for the Sludge Treatment Project (STP) corrosion process chemistry follow on testing (Delegard et al. 2007). Although most of the planned hydrothermal testing was canceled in July 2007 (as described in the forward of Delegard et al. 2007), sample consolidation and characterization was continued to identify a set of well-characterized sludge samples that are suited to support evolving STP initiatives. The work described in the letter was performed by the PNNL under the direction of the Sludge Treatment Project, managed by Fluor Hanford.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗