Search NASA⌕ Search

SEARCH · Search NASA

Results for “scan pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,063 records · Page 59

UAVSAR Phased Array Aperture

This paper describes the development of a patch antenna array for an L-band repeat-pass interferometric synthetic aperture radar (InSAR) instrument that is to be flown on an unmanned aerial vehicle (UAV). The antenna operates at a center frequency of 1.2575 GHz and with a bandwidth of 80 MHz, consistent with a number of radar instruments that JPL has previously flown. The antenna is designed to radiate orthogonal linear polarizations in order to facilitate fully-polarimetric measurements. Beam-pointing requirements for repeat-pass SAR interferometry necessitate electronic scanning in azimuth over a range of -20degrees in order to compensate for aircraft yaw. Beam-steering is accomplished by transmit/receive (T/R) modules and a beamforming network implemented in a stripline circuit board. This paper, while providing an overview of phased array architecture, focuses on the electromagnetic design of the antenna tiles and associated interconnects. An important aspect of the design of this antenna is that it has an amplitude taper of 10dB in the elevation direction. This is to reduce multipath reflections from the wing that would otherwise be detrimental to interferometric radar measurements. This taper is provided by coupling networks in the interconnect circuits as opposed to attenuating the output of the T/R modules. Details are given of material choices and fabrication techniques that meet the demanding environmental conditions that the antenna must operate in. Predicted array performance is reported in terms of co-polarized and crosspolarized far-field antenna patterns, and also in terms of active reflection coefficient.

Unmanned Aerial Vehicle (UAV)↗

Deep Data Analytics in Structural and Functional Imaging of Nanoscale Materials

Recent advances in scanning probe microscopy and scanning transmission electron microscopy have opened unprecedented opportunities in probing the materials structural parameters and electronic properties in real space on a picometre-scale. At the same time, the ability of modern day microscopes to quickly produce large, high-resolution datasets has created a challenge for rapid physics-guided analysis of data that typically contain several hundreds to several thousand atomic or molecular units per image. Here it is demonstrated how the advanced statistical analysis and machine learning techniques can be used for extracting relevant physical and chemical information from microscope data on multiple functional materials. Specifically, the following three case studies are discussed (i) application of a combination of convolutional neural network and Markov model for analyzing positional and orientational order in molecular self-assembly; (ii) a combination of sliding window fast Fourier transform, Pearson correlation matrix and canonical correlation analysis methods to study the relationships between lattice distortions and electron scattering patterns in graphene; (iii) application of a non-negative matrix factorization with physics-based constraints and Moran’s analysis of spatial associations to extracting electronic responses linked to different types of structural domains from multi-modal imaging datasets on iron-based superconductors. The approaches demonstrated here are universal in nature and can be applied to a variety of microscopic measurements on different materials.

Ziatdinov, Maxim↗

Electric current paths in a Si:P delta-doped device imaged by nitrogen-vacancy diamond magnetic microscopy

The recently-developed ability to control phosphorous-doping of silicon at an atomic level using scanning tunneling microscopy, a technique known as atomic precision advanced manufacturing (APAM), has allowed us to tailor electronic devices with atomic precision, and thus has emerged as a way to explore new possibilities in Si electronics. In these applications, critical questions include where current flow is actually occurring in or near APAM structures as well as whether leakage currents are present. In general, detection and mapping of current flow in APAM structures are valuable diagnostic tools to obtain reliable devices in digital-enhanced applications. In this report, we used nitrogen-vacancy (NV) centers in diamond for wide-field magnetic imaging (with a few-mm field of view and micron-scale resolution) of magnetic fields from surface currents flowing in an APAM test device made of a P delta-doped layer on a Si substrate, a standard APAM witness material. We integrated a diamond having a surface NV ensemble with the device (patterned in two parallel mm-sized ribbons), then mapped the magnetic field from the DC current injected in the APAM device in a home-built NV wide-field microscope. The 2D magnetic field maps were used to reconstruct the surface current densities, allowing us to obtain information on current paths, device failures such as choke points where current flow is impeded, and current leakages outside the APAM-defined P-doped regions. Analysis on the current density reconstructed map showed a projected sensitivity of ~0.03 A m -1 , corresponding to a smallest-detectable current in the 200 μm wide APAM ribbon of ~6 μA. These results demonstrate the failure analysis capability of NV wide-field magnetometry for APAM materials, opening the possibility to investigate other cutting-edge microelectronic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Analysis and Distribution of Proppant Recovered from Fracture Faces in the HFTS Slant Core Drilled through a Stimulated Reservoir

Although sand proppant has been used since 1949 to increase efficacy of hydraulically fractured treatments by preventing fractures from closing after well depressurization, many questions remain regarding the behavior and distribution of proppant in the subsurface. To this end, we quantified the amount of recovered proppant in open fractures within a slant core drilled through hydraulically fractured Wolfcamp Shale. To improve understanding of hydraulic-fracture growth and patterns, we then addressed basic questions such as the following regarding proppant behavior in the subsurface: Is there variation along the length of the examined core? Is the proppant mainly found in hydraulic fractures, in reactivated natural fractures, or is it transported into drilling-induced fractures during recovery? Do the majority of proppant grains remain whole or tend to get crushed? To answer these questions, we collected all material from every open fracture (407 samples total) within ~600 ft of core. Samples consisted of drilling mud, aluminum shavings from the core barrel, shale and lithic fragments, calcite, and, potentially, sand proppant (95% plain and 5% colored resin-coated grains) pumped during the hydraulic fracturing of adjacent wells. We then washed, sieved into four size fractions, weighed, and imaged all samples for quantitative image analysis. Retrieved samples were labeled with respect to a master fracture database, where fractures were identified in the core and on CT scans of each 3-ft interval, allowing us to code them as either hydraulic, natural reactivated, or drilling/recovery-induced fractures. From this coding, we quantified the amount of proppant within each fracture, analyzed the distribution of grains among different fracture types, and traced base versus colored grains. Proppant packs 0.5–1 cm thick were found in two locations where there was complex fracture geometry, but fracture faces showed no evidence of proppant embedment. In situ sand patches were found on a few fracture faces, mostly in fractures near the proppant packs. Pumped proppant was 100 and 40/70 mesh (149–420 μm), and even though widespread grain crushing is not observed, the majority of recovered proppant ranges from 63 to 250 μm. The distribution of retrieved proppant, especially the larger retrieved sizes (250– >500 μm), mirrors the proximity of the slant core to the hydraulic fracture treatment wells. Hydraulic fracture samples contained variable amounts of proppant, and natural reactivated fractures sometimes contained more proppant than nearby hydraulic fractures, suggesting transference between fracture types in the subsurface. Regarding colored proppant, some colored sands occurred in discreet fractures, whereas other colors appeared to be mixed and widespread. Ultimately, all fractures contain at least some proppant, especially in the smallest size fractions; however, the extent to which the proppant was introduced during the core-drilling process is still unknown. Our study is one of the first attempts at physically recovering and quantifying injected proppant from parted fracture breaks within a stimulated reservoir, and the results are significant in terms of understanding propped fracture networks and predicting future proppant distribution during hydraulic fracturing.

Elliott, Sara↗

High-Performance Acousto-Ultrasonic Scan System Being Developed

Acousto-ultrasonic (AU) interrogation is a single-sided nondestructive evaluation (NDE) technique employing separated sending and receiving transducers. It is used for assessing the microstructural condition and distributed damage state of the material between the transducers. AU is complementary to more traditional NDE methods, such as ultrasonic cscan, x-ray radiography, and thermographic inspection, which tend to be used primarily for discrete flaw detection. Throughout its history, AU has been used to inspect polymer matrix composites, metal matrix composites, ceramic matrix composites, and even monolithic metallic materials. The development of a high-performance automated AU scan system for characterizing within-sample microstructural and property homogeneity is currently in a prototype stage at NASA. This year, essential AU technology was reviewed. In addition, the basic hardware and software configuration for the scanner was developed, and preliminary results with the system were described. Mechanical and environmental loads applied to composite materials can cause distributed damage (as well as discrete defects) that plays a significant role in the degradation of physical properties. Such damage includes fiber/matrix debonding (interface failure), matrix microcracking, and fiber fracture and buckling. Investigations at the NASA Glenn Research Center have shown that traditional NDE scan inspection methods such as ultrasonic c-scan, x-ray imaging, and thermographic imaging tend to be more suited to discrete defect detection rather than the characterization of accumulated distributed microdamage in composites. Since AU is focused on assessing the distributed microdamage state of the material in between the sending and receiving transducers, it has proven to be quite suitable for assessing the relative composite material state. One major success story at Glenn with AU measurements has been the correlation between the ultrasonic decay rate obtained during AU inspection and the mechanical modulus (stiffness) seen during fatigue experiments with silicon carbide/silicon carbide (SiC/SiC) ceramic matrix composite samples. As shown in the figure, ultrasonic decay increased as the modulus decreased for the ceramic matrix composite tensile fatigue samples. The likely microstructural reason for the decrease in modulus (and increase in ultrasonic decay) is the matrix microcracking that commonly occurs during fatigue testing of these materials. Ultrasonic decay has shown the capability to track the pattern of transverse cracking and fiber breakage in these composites.

Roth, Don J.↗

Coastal Zone Color Scanner

The Coastal Zone Color Scanner (CZCS) spacecraft ocean color instrument is capable of measuring and mapping global ocean surface chlorophyll concentration. It is a scanning radiometer with multiband capability. With new electronics and some mechanical, and optical re-work, it probably can be made flight worthy. Some additional components of a second flight model are also available. An engineering study and further tests are necessary to determine exactly what effort is required to properly prepare the instrument for spaceflight and the nature of interfaces to prospective spacecraft. The CZCS provides operational instrument capability for monitoring of ocean productivity and currents. It could be a simple, low cost alternative to developing new instruments for ocean color imaging. Researchers have determined that with global ocean color data they can: specify quantitatively the role of oceans in the global carbon cycle and other major biogeochemical cycles; determine the magnitude and variability of annual primary production by marine phytoplankton on a global scale; understand the fate of fluvial nutrients and their possible affect on carbon budgets; elucidate the coupling mechanism between upwelling and large scale patterns in ocean basins; answer questions concerning the large scale distribution and timing of spring blooms in the global ocean; acquire a better understanding of the processes associated with mixing along the edge of eddies, coastal currents, western boundary currents, etc., and acquire global data on marine optical properties.

Johnson, B.↗

Discharge Chamber Performance of the NEXIS Ion Thruster

The Nuclear-Electric Xenon Ion System (NEXIS) thruster was designed to produce greater than or equal to 70% efficiency at ISPs in excess of 6500 sec and total power levels in excess of 15 kW. In order to achieve this performance, the thruster requires a large area plasma generator capable of high propellant utilimtion efficiency and low discharge loss while producing a very flat, uniform beam profile. Fortunately, larger thrusters can be made more uniform and efficient due to the higher volume to surface ratio, provided that the magnetic cusp confinement is designed properly and the thruster length to diameter ratio is adequate. This paper describes the discharge chamber performance of the NEXIS Laboratory Model (LM) thruster. The LM discharge chamber is 65 cm in diameter at the grid plane and uses 6 ring-cusps to provide magnetic confinement of the plasma. The thruster was tested with flat carbon-carbon composite grids with the hole pattern masked to 57 cm in diameter and a conventional Type-B "1/2" diameter hollow cathode. During the preliminary "discharge only" tests, the LM thruster demonstrated profile factors of 0.84 and a discharge loss of about 160 eV/ion at 25 V discharge voltage and over 90% propellant utilization efficiency in simulated beam extraction experiments at 3.9 A of beam current. Analysis of the data from these tests used the discharge-only model developed by Brophy. Subsequent beam extraction experiments validated the key variables used in the model to predict the performance from the discharge-only data, and demonstrated 3.9 A of beam current at over 90% propellant utilization efficiency with a flatness parameter of better than 0.8 and a discharge loss of about 185 eV/ion. The slightly higher discharge loss measured during beam extractions was found to be due to a lower screen transparency in the as-manufactured LM grid set. Plasma measurements with a scanning probe internal to the thruster near the screen grid showed plasma densities over l x 10(exp 11) per cubic centimeter and electron temperatures of 3.5 to 5.5 eV depending on the operation parameters. The performance of the NEXIS discharge chamber contributed to the over 78% thruster efficiency measured during beam extraction at 7500 sec ISP and 25 kW of power, and over 81% thruster efficiency measured at 8500 sec ISP.

plasma generation↗

NASA Tech Briefs, August 2006

Topics covered include: Measurement and Controls Data Acquisition System IMU/GPS System Provides Position and Attitude Data Using Artificial Intelligence to Inform Pilots of Weather Fast Lossless Compression of Multispectral-Image Data Developing Signal-Pattern-Recognition Programs Implementing Access to Data Distributed on Many Processors Compact, Efficient Drive Circuit for a Piezoelectric Pump; Dual Common Planes for Time Multiplexing of Dual-Color QWIPs; MMIC Power Amplifier Puts Out 40 mW From 75 to 110 GHz; 2D/3D Visual Tracker for Rover Mast; Adding Hierarchical Objects to Relational Database General-Purpose XML-Based Information Managements; Vaporizable Scaffolds for Fabricating Thermoelectric Modules; Producing Quantum Dots by Spray Pyrolysis; Mobile Robot for Exploring Cold Liquid/Solid Environments; System Would Acquire Core and Powder Samples of Rocks; Improved Fabrication of Lithium Films Having Micron Features; Manufacture of Regularly Shaped Sol-Gel Pellets; Regulating Glucose and pH, and Monitoring Oxygen in a Bioreactor; Satellite Multiangle Spectropolarimetric Imaging of Aerosols; Interferometric System for Measuring Thickness of Sea Ice; Microscale Regenerative Heat Exchanger Protocols for Handling Messages Between Simulation Computers Statistical Detection of Atypical Aircraft Flights NASA's Aviation Safety and Modeling Project Multimode-Guided-Wave Ultrasonic Scanning of Materials Algorithms for Maneuvering Spacecraft Around Small Bodies Improved Solar-Radiation-Pressure Models for GPS Satellites Measuring Attitude of a Large, Flexible, Orbiting Structure

Source record↗

Mid-Infrared Study of Samples from Multiple Stones from the Sutters Mill Meteorite

The Sutter's Mill meteorite fell in N. California on April 22, 2012 and numerous pieces have been recovered and studied. We present Fourier transform infrared (FTIR) spectra of fragments from several stones of the meteorite. Methods and analysis: Infrared spectra of the samples were recorded with a Nicolet iN10 MX FTIR microscope in the mid-IR range (4000-675/cm; spectral resolution 4/cm). All samples were deposited on a clean glass slide, crushed with a stainless steel roller tool, and placed directly on the focal plane of the microscope. IR spectra were collected by averaging 128 scans. Results: Preliminary IR spectra of the non-fusion crust samples show mineral compositions that are dominated by phyllosilicates, carbonates, or mixtures of both [2]. The carbonates display a dominant, broad band centered at 1433/cm, with additional bands at 2515/cm, 1797/cm, 882/cm, and 715/cm). Features associated with phyllosilicates include a symmetric Si-O stretching mode band centered at 1011/cm and several O-H stretching mode bands. The O-H shows up in two forms (1) a broadband centered at 3415/cm that is probably largely due to adsorbed H2O and (2) a much weaker, narrower feature centered near 3680/cm due to structural -OH. Features observed in the 2985-2855/cm range suggest the presence of aliphatic -CH3 and -CH2- groups. The relative intensities of the bands in this range are somewhat unusual. Typically, the asymmetric aliphatic CH stretching bands are stronger than the symmetric stretching bands, but in this case the reverse is true. This unusual pattern is well matched by the aliphatic features seen in the spectrum of a terrestrial calcite (CaCO3) standard. This observation, and the fact that the strength of the carbonate and aliphatic bands seem to correlate, suggest the organics are associated with the carbonates. Conclusions: IR spectra of samples from the Sutter's Mill meteorite show absorption features associated with carbonates, phyllosilicates, and organics. Both the unusual band profile of the aliphatic C-H stretching mode bands and their correlation with the strength of the carbonate bands suggests the organics and the carbonates are associated in some manner.

Sutter's mill↗

Spin dynamics in permalloy nano-ellipses for honeycomb and square lattices

We report experimental and theoretical studies of spin dynamics in lattice structures of permalloy (Ni 80 Fe 20 ) nano-ellipses, with four different types of networks including honeycomb and square lattices. The lattices are patterned at the center line of the co-planar wave guide and consist of non-contacting or contacting ellipses. Micromagnetic simulations show excellent agreement with the broadband ferromagnetic resonance (FMR) experimental results. We find the existence of a spin-wave mode localized in the vertex region of the contacting nano-ellipse network. Our finding has important implications when designing an artificial spin ice (ASI) network for functional magnonics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quartz conditioning crystal for X-ray rocking curve topography

A large α-quartz crystal designed to condition the monochromatic beam at beamline 1-BM of the Advanced Photon Source is presented. The purpose of this crystal was to provide a precise match to the Bragg angle of quartz crystals that are commonly used to make analyzers for plasma diagnostics. In order to characterize these analyzers, area detectors need to be positioned at distances from the analyzer at upwards of 1000 mm. As a result of this precise matching, a Bragg-reflected beam from such an analyzer is precisely parallel to the beam incident on the conditioning crystal. This situation alleviates the need to adjust the position of the area detector as the distance between the analyzer and the area detector is varied. That is, there is no need to account for vertical displacement of the diffracted-beam image as a function of this distance. Additionally, verification that the analyzer is set to the correct Bragg reflection is obtained by scanning this distance, because only for a spurious reflection will there be a vertical displacement. This is a very useful check. To commission the conditioning crystal, diffraction from a high-quality flat quartz crystal was mapped using a CCD. Bragg diffraction from the 40$\bar{40}$ reflection at 8.5 keV was studied over an area of 23 × 31 mm. The theoretical Darwin width of the flat sample in this case was 4.7 µrad. An FWHM value near 6 µrad was measured over almost the entire mapped area. These data demonstrate that the resolution function for this four-crystal arrangement is ~4 µrad. Data are also presented for a 0.1 mm-thick α-quartz wafer pressed into a concave form, having a nominal radius of 500 mm and intended for use as an analyzer. Because analyzers are bent crystals, diffraction occurs in narrow bands. When a multiple exposure is made as a function of rocking angle a striped pattern is obtained, which is commonly referred to as a zebra-stripe pattern. A series of zebra stripes from the 30$\bar{33}$ Bragg reflection of the bent wafer over its 25 mm-diameter area were recorded on a CCD. The zebra-stripe pattern was analyzed to show a uniform bending to a radius of 497.0 ± 0.3 mm, in support of the nominal value. An r.m.s. slope error of 7 µrad was also obtained from this analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Performance Acousto-Ultrasonic Scan System Being Developed

Acousto-ultrasonic (AU) interrogation is a single-sided nondestructive evaluation (NDE) technique employing separated sending and receiving transducers. It is used for assessing the microstructural condition and distributed damage state of the material between the transducers. AU is complementary to more traditional NDE methods, such as ultrasonic cscan, x-ray radiography, and thermographic inspection, which tend to be used primarily for discrete flaw detection. Throughout its history, AU has been used to inspect polymer matrix composites, metal matrix composites, ceramic matrix composites, and even monolithic metallic materials. The development of a high-performance automated AU scan system for characterizing within-sample microstructural and property homogeneity is currently in a prototype stage at NASA. This year, essential AU technology was reviewed. In addition, the basic hardware and software configuration for the scanner was developed, and preliminary results with the system were described. Mechanical and environmental loads applied to composite materials can cause distributed damage (as well as discrete defects) that plays a significant role in the degradation of physical properties. Such damage includes fiber/matrix debonding (interface failure), matrix microcracking, and fiber fracture and buckling. Investigations at the NASA Glenn Research Center have shown that traditional NDE scan inspection methods such as ultrasonic c-scan, x-ray imaging, and thermographic imaging tend to be more suited to discrete defect detection rather than the characterization of accumulated distributed micro-damage in composites. Since AU is focused on assessing the distributed micro-damage state of the material in between the sending and receiving transducers, it has proven to be quite suitable for assessing the relative composite material state. One major success story at Glenn with AU measurements has been the correlation between the ultrasonic decay rate obtained during AU inspection and the mechanical modulus (stiffness) seen during fatigue experiments with silicon carbide/silicon carbide (SiC/SiC) ceramic matrix composite samples. As shown in the figure, ultrasonic decay increased as the modulus decreased for the ceramic matrix composite tensile fatigue samples. The likely microstructural reason for the decrease in modulus (and increase in ultrasonic decay) is the matrix microcracking that commonly occurs during fatigue testing of these materials. Ultrasonic decay has shown the capability to track the pattern of transverse cracking and fiber breakage in these composites.

Roth, Don J.↗

{sup 18}F-sodium fluoride positron emission tomography assessed microcalcifications in culprit and non-culprit human carotid plaques

Background: {sup 18}F-NaF positron emission tomography (PET) targets microcalcifications. We compared in vitro microPET assessed {sup 18}F-NaF uptake between culprit and non-culprit human carotid plaques. Furthermore, we compared {sup 18}F-NaF uptake with calcification visualized on microcomputed tomography (microCT). Methods: Carotid plaques from stroke patients undergoing surgery were incubated in {sup 18}F-NaF and scanned using a microPET and a microCT scan. The average PET assessed {sup 18}F-NaF uptake was expressed as percentage of the incubation dose per gram (%Inc/g). {sup 18}F-NaF PET volume of interest (VOI) was compared with CT calcification VOI. Results: 23 carotid plaques (17 culprit, 6 non-culprit) were included. The average {sup 18}F-NaF uptake in culprit carotid plaques was comparable with the uptake in non-culprit carotid plaques (median 2.32 %Inc/g [IQR 1.98 to 2.81] vs. median 2.35 %Inc/g [IQR 1.77 to 3.00], P = 0.916). Only a median of 10% (IQR 4 to 25) of CT calcification VOI showed increased {sup 18}F-NaF uptake, while merely a median of 35% (IQR 6 to 42) of {sup 18}F-NaF PET VOI showed calcification on CT. Conclusions: {sup 18}F-NaF PET represents a different stage in the calcification process than CT. We observed a similar PET assessed {sup 18}F-NaF uptake and pattern in culprit and non-culprit plaques of high-risk patients, indicating that this method may be of more value in early atherosclerotic stenosis development. [French] French Abstract: Contexte: La tomographie par émission de positons (TEP) au {sup 18}F-NaF marque les micro-calcifications. Nous avons comparé in vitro les plaques carotidiennes humaines responsable d’accident vasculaire cérébrales marquées au {sup 18}F-NaF avec une microTEP et leur calcification au moyen d’un microCT Méthodes: Les plaques carotidiennes de patients victimes d’un accident vasculaire cérébral qui ont bénéficié d’ une intervention chirurgicale ont été incubées dans du {sup 18}F-NaF et imagées avec une microTEP et un microCT. Le pourcentage d’absorption moyen de {sup 18}F-NaF par gr de tissu (% Inc/g) ont été comparées au volume d’intérêt (VOI) des calcifications mesurées par CT. Résultats: 23 plaques carotidiennes (17 responsables d’un AVC et 6 non responsables) ont été incluses. Le % moyen d’absorption de {sup 18}F-NaF dans les plaques carotidiennes responsables furent comparable à l’absorption dans les plaques non responsables (2,32% Inc/g vs 2,35% Inc/g , p = 0,916). Dix pourcent seulement des calcifications visualisées par CT démontrèrent une augmentation d’absorption de {sup 18}F-NaF et 35% des plaques montrant une absorption de {sup 18}F-NaF PET VOI démontrèrent des calcifications au CT. Conclusions: L’imagerie de l’absorption de {sup 18}F-NaF par tomographie à positrons représente un processus physiopathologique différent de l’imagerie des calcifications par CT. L’absorption du {sup 18}F-NaF par les plaques responsables et non responsables d’accidents vasculaire cérébraux pourrait s’avérer utile dans le diagnostic précoce des sténoses athéromateuses. [Spanish] Spanish Abstract: Antecedentes: La tomografía por emisión de positrones (PET) con {sup 18}F-floruro de sodio ({sup 18}F-NaF) demuestra microcalcificaciones. En este estudio, comparamos la captación de {sup 18}F-NaF entre placas carotideas culpables y no culpables valorada con microPET in vitro. Además, comparamos la captación de {sup 18}F-NAF con las calcificaciones detectadas por microtomografía computada (microCT). Métodos: Placas carotídeas de pacientes postoperados que sufrieron de un evento vascular cerebral fueron incubadas en 18-NaF y escaneadas usando microPET y microCT. El promedio de la captación fue expresado como porcentaje de la dosis de incubación por gramo (%Inc/gr). El volumen de interés (VOI) del PET {sup 18}F-NaF se comparó con el VOI de calcificación por CT. Resultados: Se incluyeron 23 placas carotídeas (17 culpables y 6 no culpables). El promedio de la captación de {sup 18}F-NaF en placas carotídeas culpable fue comparable al de las placas no culpables. (mediana 2.32%Inc/gr [IQR1.98-2.81] vs. mediana 2.35%Inc/gr [IQR1.77-3], p=.916). Solo una mediana de 10% (IQR 4-25) del VOI en CT mostró un aumento en la captación de {sup 18}F-NaF, mientras una mediana de 35% (IQR 6-42) del VOI de PET {sup 18}F-NaF mostró calcificación en CT. Conclusiones: La tomografía por emisión de positrones con {sup 18}F-NaF evalúa una etapa distinta en el proceso de calcificación que la CT. El patrón de captación de {sup 18}F-NaF que observamos en este estudio fue similar entre placas culpables y no culpables de pacientes de alto riesgo, lo cual indica que este método puede ser de mayor valor en el desarrollo temprano de la estenosis ateroesclerótica. [Chinese] Chinese Abstract: 背景: F18 氟化钠正电子发射断层扫描 (PET) 可用于检测微钙化。我们使用微型 PET 来评估病人体外 F18 氟化钠在颈动脉罪犯和非罪犯斑块之间的的摄取区别。此外, 我们还将 F18 氟化钠的摄取与 microCT 扫描检测的钙化进行对比。 方法: 将接受手术的中风患者的颈动脉斑块在 F18 氟化钠中培养并用 microPE 和 microCT 进行扫描。PET 对 F18 氟化钠的平均摄取率表示为每克培养剂量的百分比。F18 氟化钠 PET 中的感兴趣区域和 CT 钙化图像中的感兴趣区域 (VOI) 进行比较。 结果: 一共有 23个颈动脉斑块, 其中 17个罪犯斑块和 6个非罪犯斑块。罪犯和非罪犯颈动脉斑块的 F18 氟化钠的平均摄取率无明显差异 (中值 2.32 % Inc/g [IQR 1.98-2.81] vs. 中值2.35 % Inc/g [IQR 1.77-3.00], p = 0.916)。仅中值为10% [IQR 4-25] 的 CT 钙化 VOI 显示有F18氟化钠的摄取增加, 中值为 35%[IQR 6-42] 的 F18 氟化钠 PET VOI 显示有CT 上的钙化。 结论: 相较于 CT, F18 氟化钠 PET 展现了钙化过程中的一个不同阶段。在高危病人中, 我们观察到罪犯和非罪犯斑块具有类似的 PET F18 氟化钠摄取和模式, 表明该方法可能在早期动脉粥样硬化狭窄发展中具有更高的价值。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mineralogical, Elemental, and Tomographic Reconnaissance Investigation for CLPS (METRIC)

METRIC is a robotic science laboratory that can determine the mineralogy, elemental chemistry, micromorphology, and thermophysical properties of planetary regolith. The METRIC suite comprises METRIC XRD/F, an X-ray diffraction/X-ray fluorescence instrument that can determine the mineralogy and elemental chemistry of regolith samples; METRIC XCT, a micro X-ray computed tomography instrument that can be used to evaluate grain/crystallite sizes and textures; METRIC IRS, an imaging spectrometer mounted on a rover that can determine mineralogy and thermophysical properties at the landing site; and a pneumatic sample collection, processing, distribution system developed by Honeybee Robotics. The payload elements could be deployed on a static lander or a rover. Data returned from the METRIC payload would inform origin, formation, and evolution of rocky planetary bodies. METRIC XRD/F draws on heritage from the CheMin instrument on the Mars Science Laboratory (MSL) Curiosity rover [1], with a few important improvements. Like CheMin, METRIC XRD/F operates in transmission geometry and uses piezoelectric actuators on sample cells in a tuning fork geometry to induce convective grain motion of the regolith to create a randomly oriented powder. MSL CheMin uses an energy-sensitive CCD to collect XRD patterns and XRF spectra simultaneously from the same sample cell, resulting in qualitative XRF data. METRIC XRD/F uses two different sample cells, one optimized for XRD and one optimized for XRF, and a silicon drift detector to detect fluoresced X-rays. This improvement to the XRF capabilities provides quantitative geochemical data of major elements down to Z = 11 and allows for the detection of minor and trace elements that are critical for evaluating geologic evolution of the Moon (e.g., P and Th). Modest improvements to the XRD geometry and hardware allow for better angular resolution and the ability to distinguish between members of the pyroxene group. METRIC XCT uses the same geometry and much of the same hardware as METRIC XRD/F, where a CCD would capture images of a regolith sample in a 3 mm diameter sample tube that is rotated 360° in steps <1°. Image brightness can be used to infer compositional data, where brighter materials indicate a higher Z, much like scanning electron microscopy. Data from METRIC XCT complement those from METRIC XRD/F. Particle size, shape, and texture can provide petrologic and provenance information, whereas vesicle size and morphology in volcanic or impact melt lithologies can inform cooling rates. METRIC IRS is a hyperspectral thermal imager that can be mounted to a lander or rover to provide mineralogical data from the broader landing site and help determine whether the samples analyzed by METRIC XRD/F and XCT are representative. The METRIC IRS spectral range (8–14 μm) and resolution (10.8 cm-1) allow for quantitative mineralogy from modelling Reststrahlen bands of major rock-forming minerals (e.g., silicates, phosphates). Radiance cubes can be processed and modelled with an onboard high-performance computer to determine mineral abundances of plagioclase, high-Ca pyroxene, pigeonite, orthopyroxene, olivine, and glass. Regolith samples can be acquired, processed, and delivered to the X-ray instruments via multiple sample handling systems, but the pneumatic sampling systems developed by Honeybee Robotics [e.g., 2] are best suited for relatively low-cost missions that are being competed for the Moon (e.g., NASA’s Payloads and Research Investigations for the Surface of the Moon program). There are pneumatic sampling systems that collect surface material and other systems that pneumatically drill up to ~1 m below the surface, providing material that has not been space weathered and has not been affected by the lander’s exhaust. [1] Blake, D. F., Vaniman, D., Achilles, C., Anderson, R., Bish, D., et al. (2012). Space Sci. Rev. 170, 341-478. https://doi.org/10.1007/s11214-012-9905-1. [2] Zacny, K., Betts, B., Hedlund, M., Long, P., Gramlich, M., Tura, K., Chu, P., Jacob, A., Garcia, A. (2014). IEEE Aerospace Conference, 3-7 March 2014, Big Sky, MT, U.S.A.

X-ray diffraction↗

Probing free carrier plasmons in doped semiconductors using spatially resolved electron energy loss spectroscopy

We report spatially resolved measurements of free carrier collective excitations in a doped semiconductor. Using ~10 meV resolution electron energy loss spectroscopy (EELS) in an electron microscope with Å spatial resolution, we identify both surface and bulk carrier plasmons at infrared energies in a freestanding film of indium tin oxide (ITO). The interference patterns of long wavelength propagating surface carrier plasmons are revealed using spatially resolved EELS, from which we extract a dispersion relation. We further show that the energies of these plasmons vary near the surfaces and grain boundaries of the film due to band bending. Modeling based on dielectric theory agrees very well with experimental results. Finally, carrier plasmons in amorphous and crystalline ITO films are compared. These results should also be helpful for understanding the free carrier plasmons in other doped semiconductors in nanoscale volumes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Carbon Nanotube Based Nano-Electro-Mechanical Systems (NEMS)

Carbon nanotubes (CNT) enable nanoelectromechanical systems (NEMS) because of their inherent nanostructure, intrinsic electric conductivity and mechanical resilience. The collaborative work between Stanford (experiment) and NASA Ames (theory and simulation) has made progress in two types of CNT based NEMS for nanoelectronics and sensor applications. The CNT tipped scanning probe microscopy (SPM) is a NEMS in which CNT tips are used for nanoscale probing, imaging and manipulating. It showed great improvement in probing surfaces and biological systems over conventional tips. We have recently applied it to write (lithography) and read (image) uniform SiO2 lines on large Si surface area at speed up to 0.5 mm per s. Preliminary work using approximately 10 nm multiwall nanotube tips produced approximately 10 nm structures and showed that the CNT tips didn't wear down when crashed as conventional tips often do. This presents a solution to the long standing tip-wear problem in SPM nanolithography. We have also explored potential of CNT tips in imaging DNA in water. Preliminary experiment using 10 nm CNT tips reached 5 nm resolution. The 1 nm nanolithography and 1 nm DNA imaging can be expected by using approximately 1 nm CNT tips. In contrast to CNT tipped SPM, we also fabricated CNT devices on silicon wafer in which CNTs connect patterned metallic lines on SiO2/Si by a simple chemical vapor deposition process. Using conventional lithography for silicon wafer, we have been able to obtain CNT based transistors and sensors. Investigations of the CNT NEMS as physical, biological and chemical sensors are in progress and will be discussed.

Han, Jie↗

Model study of the energy dependence of the correlation between anisotropic flow and the mean transverse momentum in Au + Au collisions

A hybrid model that employs the hadron-string transport model UrQMD and the (3+1)-dimensional relativistic viscous hydrodynamic code vHLLE, is used to investigate the beam energy dependence of the correlation coefficient ρ(v$^{2}_{2}$,[p T ]) between the average transverse momentum [p T ] of hadrons emitted in an event and the square of the anisotropic flow coefficient v$^{2}_{2}$. For Au+Au collisions, the model predicts characteristic patterns for the energy and event-shape dependence of the variances for [p T ] and v$^{2}_{n}$ [Var([p T ] and Var(v$^{2}_{2}$)], and the covariance of v$^{2}_{n}$ and [p T ][cov(v$^{2}_{2}$,[p T ])], consistent with the attenuation effects of the specific shear viscosity η/s. Here in contrast, ρ(v$^{2}_{2}$,[p T ]) is predicted to be insensitive to the beam energy but sensitive to the initial-state geometry of the collisions. These observations suggest that a precise set of measurements for Var([p T ]), Var(v$^{2}_{2}$), cov(v$^{2}_{2}$,[p T ]) and ρ(v$^{2}_{2}$,[p T ]) as a function of beam energy and event shape, could serve to constrain better the eccentricities and their fluctuations over the entire span of beam energies, and consequently aid precision extraction of the temperature and baryon chemical-potential dependence of η/s from the wealth of Au+Au data obtained in the RHIC beam energy scan.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crosslinked Polyacrylamide Composite Hydrogels Impregnated with Fly Ash: Synthesis, Characterization and Their Application as Fractures Sealant for High Water Producing Zones in Oil and Gas Wells

Polymeric hydrogels are designed to serve many purposes in various fields of human endeavor. Herein, crosslinked polyacrylamide (PAM) composite hydrogels impregnated with coal fly ash (CFA) were synthesized, characterized and tested as fracture sealing agents in high water producing permeable zones in petroleum industry. The concept of utilizing CFA as an inorganic additive in the matrix of hydrogel emanates from the fact that CFA constitutes majorly alumina and silica. Both chemical oxides can induce the CFA to promote the inherent properties of hydrogel. Polyethyleneimine (PEI) was chosen as the crosslinking agent. Neat PAM/PEI hydrogel and PAM/PEI–CFA hydrogels at various CFA loadings (0.5, 1 and 2 wt%) were synthesized via a transamidation reaction pathway. The developed hydrogels were characterized by hybrid rheometer, FTIR, SEM and XRD instruments. Rheological results reveal that the PAM/PEI–CFA composite hydrogels embedded with various CFA quantities were more elastic than the neat PAM/PEI hydrogel, indicating the dispersion and reinforcing effect of CFA. The functional groups of these hydrogels were confirmed by the FTIR while SEM analysis show that the surface micrographs of neat PAM/PEI hydrogel and PAM/PEI–CFA1 hydrogel were porous in several regions. In contrast, the micrographs of PAM/PEI–CFA2 and PAM/PEI–CFA3 hydrogels demonstrated dense and “net-like” structural patterns. Further, XRD analysis revealed that CFA impregnation has a significant effect on the bulk structural properties of the fabricated hydrogels. The swelling rates of these hydrogels were determined by the gravimetric method and their diffusion parameters evaluated using Fickian diffusion and Schott-order kinetic models. Efficacy of the PAM/PEI–CFA composite hydrogel as fractures sealant in oil and gas wells was conducted at a typical reservoir temperature, 90 °C, and the outcome demonstrated considerable sealing potency.

36 MATERIALS SCIENCE↗